TIME OF FLIGHT GC/MSTOF

Similar documents
TOF. Plus. Time of Flight GC/MS. The New Concept of High Speed TOF-MS. Extremely Compact Design. High Sample Throughput

Multi-residue analysis of pesticides by GC-HRMS

Benefits of Equipping your Lab with a Time-of-Flight Mass Spectrometer

HIGH SPEED GC-TOFMS FOR ESSENTIAL OILS PROFILING IN ROUTINE QUALITY ASSESSMENT

Analytical Instrumentation

All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems

Characterisation of allergens in cosmetics by GC GC TOF MS with Select-eV variable-energy electron ionisation

New Approaches to the Development of GC/MS Selected Ion Monitoring Acquisition and Quantitation Methods Technique/Technology

Cerno Bioscience MassWorks: Acquiring Calibration Data on Agilent GC/MSDs

EGASUS. 4D GCxGC TOFMS. Delivering the Right Results

UNIQUE SOLUTION FOR FLAVOUR AND FRAGRANCE IDENTIFICATION BY MEANS OF GC-MS (TOF) / CONDENSED PHASE FTIR

GAS CHROMATOGRAPHY MASS SPECTROMETRY. Pre-Lab Questions

Introducing the Agilent 7000A QQQ-MS for GC Sunil Kulkarni Product Specialist Agilent Technologies

SIFT-MS SELECTED ION FLOW TUBE MASS SPECTROMETRY TECHNOLOGY OVERVIEW \ SYFT TECHNOLOGIES

Author. Abstract. Introduction

Overview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada)

Forensic Toxicology. Analysis of Ethanol in Blood using Master SHS Static Headspace Sampler and Master GC Gas Chromatograph APPLICATION NOTE

SIFT-MS. technology overview

Quadrupole Time-of-Flight Liquid Chromatograph Mass Spectrometer LCMS-9030 C146-E365

Analysis of Biomarkers in Crude Oil Using the Agilent 7200 GC/Q-TOF

U.S. EPA Method 8270 for multicomponent analyte determination

We don t have anything against mass spectrometry. We just think it s time for a worthy alternative.

MassHunter TOF/QTOF Users Meeting

Highly Sensitive and Rugged GC/MS/MS Tool

The 5975 inert MSD Benefits of Enhancements in Chemical Ionization Operation Technical Note

Identification and Quantitation of PCB Aroclor Mixtures in a Single Run Using the Agilent 7000B Triple Quadrupole GC/MS

The Importance of Area and Retention Time Precision in Gas Chromatography Technical Note

Introduction to GC/MS

Identifying Pesticides with Full Scan, SIM, µecd, and FPD from a Single Injection Application

GAS CHROMATOGRAPHY (GC)

Multi-residue GC-MS analysis. Richard Fussell CSL York, UK

IRMS. perspective. Isotope Ratio Mass Spectrometry.

Analysis of TO-15/TO-17 air toxics in urban air using TD GC/TOF MS and automated compound identification software

Automated and accurate component detection using reference mass spectra

brochure brief 5973Network Mass Selective Detector General Description and Configurations

Workflow Using Hyphenated Mass Spectrometry Techniques

MassHunter Software Overview

Accurate Mass Measurement for Intact Proteins using ESI-oa-TOF. Application Note. Donghui Yi and Christine Miller Agilent Technologies

Determination of Hydrocarbon Components in Petroleum Naphthas

MassHunter METLIN Metabolite PCD/PCDL Quick Start Guide

Agilent All Ions MS/MS

Analysis of Ethanol and Isotopomers by 240 Quadrupole Ion Trap GC/MS

ICP-MS. High Resolution ICP-MS.

TOXICOLOGY & FORENSIC APPLICATIONS

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW

Screening for Water Pollutants With the Agilent SureTarget GC/MSD Water Pollutants Screener, SureTarget Workflow, and Customized Reporting

Translational Biomarker Core

Determination of 59 potential Allergens in Perfumes by twin-line fast GCMSMS

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

HYPHENATED TECHNOLOGY GUIDE

The Analysis of Trace Contaminants in High Purity Ethylene and Propylene Using GC/MS. Application. Agilent Technologies/Wasson ECE Monomer Analyzer

We don t have anything against mass spectrometry. We just think it s time for a worthy alternative.

Finnigan TRACE DSQ GC/MS

Benzene Contamination in BabyFood and Beverages by New Generation of Static Headspace Autosampler coupled to Fast GC-TOFMS

Analyst Software. Automatic Optimization Tutorial

Thermo Scientific ICP-MS solutions for the semiconductor industry. Maximize wafer yields with ultralow elemental detection in chemicals and materials

HYPHENATED TECHNOLOGY GUIDE

110 Lowell Rd Hudson, NH USA Tel:

Bruker Daltonics. EASY-nLC. Tailored HPLC for nano-lc-ms Proteomics. Nano-HPLC. think forward

Chemical Analysis. PIONA+ Analyzer. Characterization of Engine Fuels by Hydrocarbon Group Type. Gas Chromatography. think forward

Analysis of allergens found in cosmetics using MDGC-GCMS (Multi-Dimensional Gas Chromatograph Mass Spectrometer)

Analyst Software. Peptide and Protein Quantitation Tutorial

PesticideScreener. Innovation with Integrity. Comprehensive Pesticide Screening and Quantitation UHR-TOF MS

Fast USEPA 8270 Semivolatiles Analysis Using the 6890/5973 inert GC/MSD with Performance Electronics Application

MM 2. Innovation with Integrity. The new Generation of Mobile Mass Spectrometers. Defence CBRNE

WADA Technical Document TD2003IDCR

Analysis of Natural Oils and Extracts Using the Low Thermal Mass LTM Series II System

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

Agilent 7500a Inductively Coupled Plasma Mass Spectrometer (ICP-MS)

Analysis of Sulfur-Containing Flavor Compounds By GC/MS With A PFPD

Characterisation of allergens in cosmetics by GC GC TOF MS with Select-eV variable-energy electron ionisation

high performance OPTIC 3 and applications a total analytical solution

The Claviature of Gas Analysis

Pittcon P

Agilent TOF Screening & Impurity Profiling Julie Cichelli, PhD LC/MS Small Molecule Workshop Dec 6, 2012

Using TOF for Screening and Quantitation of Sudan Red Colorants in Food Application

Cerno Application Note Extending the Limits of Mass Spectrometry

Analysis of domestic sludge using the Agilent 4200 MP-AES

Cerno Application Note Extending the Limits of Mass Spectrometry

Application Note. Gas Chromatography/Mass Spectrometry/Food Safety. Abstract. Authors

Meeting Challenging Laboratory Requirements for USEPA Method 8270 Using a Highly Sensitive, Robust, and Easy-to-Use GC/MS

The Analysis of Residual Solvents in Pharmaceutical Products Using GC-VUV and Static Headspace

Defining quality standards for the analysis of solid samples

Separation of Explosives in EPA 8330: Column Choices Optimize Speed, Resolution, and Solvent Use. Application. Authors. Abstract.

Quantification of Pesticides in Food without Calibration using GC/FID with the Polyarc Reactor

Simplified Approaches to Impurity Identification using Accurate Mass UPLC/MS

Making Sense of Differences in LCMS Data: Integrated Tools

Agilent MassHunter Profinder: Solving the Challenge of Isotopologue Extraction for Qualitative Flux Analysis

Agilent G3212 GC-APCI Source

Determination of VOCs by USEPA Method 8260 with Extended Dynamic Range using Fast, Sensitive Capillary GC/MS

Detection of Volatile Organic Compounds in polluted air by an Agilent mini Thermal Desorber and an Agilent 5975T LTM GC/MS

Analysis of complex petrochemicals by GC GC TOF MS with Select-eV variable-energy electron ionisation

Agilent 5977A Series GC/MSD System

Application Note 12: Fully Automated Compound Screening and Verification Using Spinsolve and MestReNova

Introduction. Chapter 1. Learning Objectives

MS n Analysis With Fast Polarity Switching in the Agilent 1100 Series LC/MSD Trap SL. Application Note. Christine Miller Agilent Technologies

Catalysis CAPABILITIES

Finnigan LCQ Advantage MAX

Fast Results Anytime, Anywhere

FORENSIC TOXICOLOGY SCREENING APPLICATION SOLUTION

Transcription:

A New Concept of TOF-MS for the Latest Generation GC Techniques When productivity is the name of the game, MASTER TOF-MS is the answer Productivity has become of vital importance in most modern laboratories. The automated and unattended processing of a larger number of samples per day is the real challenge to increase productivity and reduce costs/analysis. Additionally, Fast GC has resulted in a very effective way to address this challenge providing a significant decrease in the analysis time. However, when a positive identification is mandatory and mass spectrometric detection is needed, conventional Quadrupoles or Ion Trap Mass Spectrometers do not provide enough information for a reliable peak reconstruction of very narrow peaks over the full mass range. Time of Flight Mass Spectrometry (TOF-MS) is the only technology capable of properly coping with this requirement due to its fast acquisition rate. DANI MASTER TOF-MS detector performs the fastest acquisition rates (1000 spectra/s) 5 and the widest linear dynamic range (10 ) available on the market. These capabilities are offered in a truly affordable and extremely compact bench-top instrument. In combination with the MASTER GC, the system is the ideal solution for Fast GC and GCxGC analyses to obtain improved productivity and performance. The simple and intuitive MASTER LAB software offers the proper tool for a reliable control of the system, from autotuning procedures to GC and sample sequence management. It also provides a powerful data processing solution and an original deconvolution algorithm capable to handle the large amount of information in a smart and effective way resulting in a reliable identification of trace compounds even in complex matrices. EXTREMELY COMPACT DESIGN TIME OF FLIGHT GC/MSTOF HIGH PRODUCTIVITY POWERFUL SOFTWARE SOLUTION WALKAWAY AUTOMATION

High Productivity The use of automated instrumentation and Fast GC methods are the right approach for modern laboratories to enhance their productivity, reducing the run time and increasing the accuracy and precision of their analyses. The Master TOF Time of Flight GC/MS system fulfills all the stringent requirements that Fast GC imposes to the analytical instrumentation, including the fast heating and cooling rate of the GC oven, the high pressure limit of the gas control and, finally, the fast acquisition rate of the MS detector. Particularly, the narrowest chromatographic peaks produced by high speed analyses, having a 0.5 seconds or lower peak width, require a high speed acquisition rate to collect a sufficient number of information (15-20 points/peak) for a correct peak identification of a fully resolved peak. Furthermore, a higher number of data points is mandatory for an accurate recognition and quantification of unknown and coeluting peaks typically present in complex samples. The MASTER TOF-MS provides an acquisition rate up to 30,000 spectra/s offering the fastest MS detection available on the market. In addition, the TOF-MS principle allows the fast detection capability over the full mass range: in fact, all the ions generated in the ion source are continuously pulsed into the analyzer and no filtering of selected masses is applied. This overcomes the need for SIM mode operation used in conventional quadrupoles or ion-traps and limits the spectral skewing of unresolved peaks produced by scanning instruments. The MASTER TOF-MS constantly acquires 30,000 mass spectra over the entire mass range, compared to the fastest quadrupole MS which only provides about 10 mass spectra at 10,000 amu/s in the same mass range (1 1,000 amu). All spectra acquired are stored in a compressed format to provide a continuous full mass range acquisition rate selectable up to 1000 Hz written to disk. Walkaway Automation In combination with the MASTER AS, a robotic X-Y-Z coordinate sampling system, the MASTER TOF GC/MS system delivers complete automation of all operation steps, including standard addition. Hence, the complete system increases sample throughput allowing to process without attending up to 160 samples with enhanced precision and accuracy, improving analysis performance. The MASTER Lab software delivers complete system control through a user-friendly interface without requiring particularly experienced operators. Full Instrument Control and Powerful Data Management The MASTER Lab software integrates the control of MASTER TOF-MS, MASTER GC, MASTER AS, and other DANI autosamplers like the Thermal Desorber and the Dynamic Head Space Sampler. The maximum productivity is obtained through the full automation of the process, starting from sampling, to acquisition, data processing and reporting. Methods and sequences can be easily created, edited, stored, and uploaded to the instruments. A full diagnostic is also included and provides information on the instrument status. In addition to the local control, DANI is also capable to provide a remote control function based on an Internet connection. The on-line support connection allows the DANI service staff to remotely operate on the instrument located at customer site. DANI remote control service permits basic diagnostic tests and a quicker flow of information from the specialist to the user. Minimized dead times and reduced on-site service cost add a further improvement to the gain of high productivity. Report In addition, the system offers an outstanding dynamic range with a linearity of 5 orders of magnitude, remarkably reducing sample preparation steps, e.g. dilutions and concentrations, as well as the number of analyses. The MASTER TOF-MS, matching the speed required for the acquisition of the narrowest GC peaks, is also the ideal solution for GCxGC applications. Master TOF with Master GC Personal Computer Remote Control

41 cm Extremely Compact Design In today's world economy, also analytical laboratories have to deal with the increasing cost of their working environment; consequently, their choices are often restricted by a limited space. For this reason, the compactness of the instrumentation is increasing of importance and manufacturers have to pay special attention to this specification. Unlike other TOF-MS detectors, the extremely compact design of the MASTER TOF-MS allows it to be the smallest bench-top instrument of its class. Easy Maintenance Unlike other commercial available TOF-MS detectors, the MASTER TOF-MS design simplicity permits the user to easily access the ion source. Fast, uncomplicated, and efficient maintenance procedures can be carried out requiring just an Allen wrench and low labor input. For extra convenience, the MASTER TOF-MS is equipped with a double filament. In case of filament damage the second filament can be used proceeding with the analyses without stopping the work schedule of the laboratory. 22 cm 53 cm In a minimal bench space, MASTER TOF-MS includes the baking pump thus providing a highly handy and noise-free instrument. Complete Line for Total Solutions The MASTER GC allows the easy assembly of a complete range of injectors, including split/splitless and PTV. The PTV is particularly suggested when high sample integrity is requested. Enhanced Sensitivity The MASTER TOF-MS features an unsurpassed sensitivity. Unlike scanning quadrupole MS, which generates inconstant ion-abundance ratios, the MASTER TOF-MS provides enhanced sensitivity due to the high frequency of ions expulsions (30,000 Hz), the fast acquisition system (1.2 GSPS), and the negligible ion loss during the separation process in the flight tube. In addition, high sensitivity is maintained across the entire mass range. The MASTER GC also features a complete line of detectors compatible with Fast GC applications, such as Flame Ionization Detector (FID), Electron Capture Detector (ECD), Nitrogen-Phosphorus Detector (NPD), and Flame Photometric Detector (FPD). The MASTER GC can be equipped with up to three detectors simultaneously. In addition, the MASTER TOF GC/MS system delivers complete volatile extraction when combined to the DANI autosamplers MASTER DHS Dynamic Head Space Sampler, MASTER TD Thermal Desorber, and HSS 86.50 Head Space Sampler. Outstanding sensitivity is achieved through the use of differential pumping, enabling improved vacuum conditions. Therefore, an elongated ion mean free path is achieved, avoiding collision on their transit through the TOF analyzer. 1 pg OFN S/N 150:1 (RMS) extracting the m/z 272 ion on raw data

Innovative Master Lab Software Solution The proprietary MASTER Lab software solution is based on an innovative platform for acquiring and processing mass spectral data. The software ensures high level performance and maximized productivity, while delivering the flexibility and robustness required in laboratories with high daily sample throughput. Processing: Calibration, Deconvolution, Quantitative, and Qualitative Analyses After the acquisition, the mass spectral data are processed, enabling the access to peak identification, integration, and calibration. Calibration curves and quantitative analysis of known and unknown components are calculated automatically. In GC analyses co-elutions are prone to occur when complex samples are analyzed or when the analysis run times are reduced. The MASTER Lab algorithms use automatic spectral deconvolution procedures to detect overlapped peaks. The unresolved mass spectra are deconvoluted, pure mass spectra are generated and then submitted as unknowns to mass spectral library search. The software supports several mass spectral libraries, such as the NIST mass spectral library and Adams MS Library (Allured Publishing Corp.) among others. Improved effectiveness and confidence in the identification and screening of target and non target compounds is achieved. 69 Pesticides in about 4 minutes ZOOM OF DECONVOLUTED AREA 1 2 TIC 120 176 264 306 Autotune The MASTER Lab allows the system to automatically tune the performance checks; manual tuning is also available. In the autotuning mode the various instrument control parameters are automatically adjusted as specified in the Autotuning Conditions. Furthermore, tuning conditions can be customized and saved to fit specific analytical requirements. The tuning criteria are saved in a tuning file, along with the obtained results. Data Acquisition Data acquisition initiates after the fast and easy method set up. The chromatogram and the spectrum are displayed in real time, as well as the acquisition method. Report Analysis reports can be customized and stored as report files, which can be repeatedly used. Reports can also be automatically generated to improve the output of routine laboratories. Data Export Obtained data can be exported to several standard data formats, e.g. net.cdf and.txt files. The creation of.xls worksheets is also enabled. The convenient file export can be performed automatically or manually. The Total Ion Current (TIC) chromatogram obtained from the analysis of a complex sample shows a single peak. The original automatic spectral deconvolution of Master Lab software has identified that two different compounds are actually co-eluting. Their deconvoluted spectra, extracted from co-eluting peaks, noise and matrix background, are then matched against the mass spectral library for their identification. MASS SPECTRUM OF PEAK MARKED 1 MASS SPECTRUM OF PEAK MARKED 2

Significant Improvement in Analytical Separation Power The combination of the MASTER GC and the MASTER AS hyphenated to the MASTER TOF-MS is the right solution for your daunting analytical tasks and is adequate for a broad range of applications. Cosmetics and Toiletries (C&T) The investigation of allergens in C&T matrices is of utmost importance for safety evaluation procedures. Allergens are strictly regulated and maximum residue limits for leave-on and rinseoff cosmetic products are of 0.001 % and 0.01 %, respectively. The MASTER TOF GC/MS system permits reliable allergens mass spectra identification due to automatic deconvolution and high productivity thanks to the excellent quantitative determination of trace level components. Allergens determination in commercial perfume. Limonene Linalool Neral Geranial alpha - Isomethylionone Eugenol Isoeugenol Flavor and Fragrances (F&F) Fragrance materials are composed of a wide range of compounds blended to create sophisticated perfumes. As it is well known, the use of modern analytical methods boosted the acquisition of higher perfumery raw material knowledge and GC has been widely employed in perfumery industries. In the F&F application field faster analysis, rapid and reliable peak assignment are continuously required. The MASTER TOF GC/MS system fulfills these productivity requirements. Lyral Agriculture Pesticide residues analyses in agricultural products are generally carried out by using GC in combination with selective detectors, such as Nitrogen-Phosphorous Detector (NPD) or Electron Capture Detector (ECD). Fast GC drastically reduces analysis time and spectra deconvolution permits reliable compound identification. The use of the MASTER TOF-MS detector is unprecedented for precise peak assignment and structural elucidation. ZOOM OF DECONVOLUTED AREA In a mint oil sample, the deconvolution has allowed the identification of Etridiazole. The pesticide, that is present only in traces, looks as a small baseline deviation in the TIC chromatogram. TIC 183 211 The TIC chromatogram obtained from the Fast GC analysis of a perfumery raw material shows several co-eluting peaks. The constant ion abundance ratios across the chromatographic peak, the high acquisition rates, and the unskewed mass spectra are uniquely produced by the MASTER TOF-MS and support the deconvolution algorithm for the peak picking of the components. Productivity and accurate peak identification are obtained simultaneously. ZOOM OF DECONVOLUTED AREA Hedione Hexyl Salicylate ISO E SUPER (Isomer 1) ISO E SUPER (Isomer 2) Hedione (Isomer) ISO E SUPER (Isomer 3) TIC 120 135 191 83 Further Application Areas Petrochemical, Fuels, and Energy Environmental Monitoring Food and Beverages Security and Forensics Material Science

DANI A SCENT OF FUTURE DANI A SCENT OF FUTURE TIME OF FLIGHT GC/MS TOF EXTREMELY COMPACT DESIGN AUTHORIZED DEALER HIGH PRODUCTIVITY POWERFUL SOFTWARE SOLUTION Disclaimer The contents of this brochure are for reference and illustrative purposes only. Information, descriptions and specifications in this publication are subject to change without notice. DANI Instruments S.A. assumes no responsibility and will not be liable for any errors or omissions contained herein or for incidental, consequential damages or losses in connection with the furnishing, performance or use of this material. For a complete listing of our products visit www.danisa.ch WALKAWAY AUTOMATION