Analysis of domestic sludge using the Agilent 4200 MP-AES

Similar documents
Elemental analysis of river sediment using the Agilent 4200 MP-AES

Determination of major, minor and trace elements in rice fl our using the 4200 Microwave Plasma- Atomic Emission Spectrometer (MP-AES) Authors

Ultra-fast determination of base metals in geochemical samples using the 5100 SVDV ICP-OES

Application note. Determination of exchangeable cations in soil extracts using the Agilent 4100 Microwave Plasma-Atomic Emission Spectrometer

Today s Agilent Solutions for Determining Heavy Metals in Food using Atomic Spectroscopy

ICP-OES Application Note Number 35

Determination of Pb, Cd, Cr and Ni in Grains Based on Four Chinese National Methods via Zeeman GFAAS

The Investigation of Fertilizer Analyses Using Microwave Digestion and the Agilent 720-ES

Enhancing the productivity of food sample analysis with the Agilent 7700x ICP-MS

High-Speed Environmental Analysis Using the Agilent 7500cx with Integrated Sample Introduction System Discrete Sampling (ISIS DS)

The Agilent 7700x ICP-MS Advantage for Drinking Water Analysis

Fast Analysis of Water Samples Comparing Axially-and Radially- Viewed CCD Simultaneous ICP-OES

Multi-Element Analysis of Cannabis using the Agilent 7800 ICP-MS

Multi-Element Analysis of Petroleum Crude Oils using an Agilent 7900 ICP-MS

Meeting the Challenges of Soil Analysis with the Avio 200 ICP-OES

High Throughput Water Analysis using Agilent 7900 ICP-MS coupled with ESI prepfast

Simple and Reliable Soil Analysis using the Agilent 7800 ICP-MS with ISIS 3

Direct Measurement of Metallic Impurities in 20% Ammonium Hydroxide by 7700s/7900 ICP-MS

U.S. EPA SW-846 Method 6010C using the Prodigy High Dispersion ICP

Total Elemental Analysis of Food Samples for Routine and Research Laboratories, using the Thermo Scientific icap RQ ICP-MS

Rapid Analysis of High-Matrix Environmental Samples Using the Agilent 7500cx ICP-MS. Application. Author. Abstract. Introduction.

U.S. EPA SW-846 Method 6010C Using the Prodigy7 High- Dispersion ICP Introduction. Application Note - AN1305. Experimental

Trace elemental analysis of distilled alcoholic beverages using the Agilent 7700x ICP-MS with octopole collision/ reaction cell

The ultratrace determination of iodine 129 in aqueous samples using the 7700x ICP-MS with oxygen reaction mode

Simple, reliable analysis of high matrix samples according to US EPA Method 6020A using the Agilent 7700x/7800 ICP-MS

Analysis of high matrix samples using argon gas dilution with the Thermo Scientific icap RQ ICP-MS

Determination of Chromium in Gelatin Capsules using an Agilent 7700x ICP-MS

Test Method: CPSC-CH-E

Total elemental analysis of food samples for routine and research laboratories using the Thermo Scientific icap RQ ICP-MS

Determination of trace elements in ultrapure semiconductor grade sulfuric acid using the Agilent 8900 ICP-QQQ in MS/MS mode

China Soil Pollution Survey: Elemental Analysis of Soil and Sediment Digests by ICP-MS

Direct Determination of Aluminium in Milk by Graphite Furnace Atomic Absorption Spectrometry

High-Throughput Semiquantitative Screening of Ambient Air Samples by ORS-ICP-MS and Integrated Sample Introduction System (ISIS) Application

Basic Digestion Principles

Using FIMS to Determine Mercury Content in Sewage Sludge, Sediment and Soil Samples

Analysis of trace elements in polymer samples to ensure compliance with WEEE-RoHS standards using the Thermo Scientific icap 7200 ICP-OES

Hydride Generation for the Determination of As, Sb, Se and Bi Using the Teledyne Leeman Lab s Prodigy 7 ICP-OES

Brooklyn College Department of Chemistry

Hach Method Total Organic Carbon in Finished Drinking Water by Catalyzed Ozone Hydroxyl Radical Oxidation Infrared Analysis

Samples compliant with the WATER

Application of the Agilent 7900 ICP-MS with Method Automation function for the routine determination of trace metallic components in food CRMs

Direct Determination of Cadmium and Lead in honey by Electrothermal Atomization Atomic Absorption Spectrometry with Zeeman Effect Correction

Analysis of Arsenic, Selenium and Antimony in Seawater by Continuous-Flow Hydride ICP-MS with ISIS

Direct Analysis of Trace Metal Impurities in High Purity Nitric Acid Using ICP-QQQ

Elemental Scientific. Spike Recovery. Elemental Scientific

Quantitative analysis of high purity metals using laser ablation coupled to an Agilent 7900 ICP-MS

The Determination of Toxic, Trace, and Essential Elements in Food Matrices using THGA Coupled with Longitudinal Zeeman Background Correction

Thermo Scientific icap RQ ICP-MS: Typical limits of detection

Zinc Metal Determination Perkin Elmer Atomic Absorption Spectrometer AAnalyst Procedures

Application. Determination of Trace Metal Impurities in Semiconductor-Grade Hydrofluoric Acid. Authors. Introduction. Abstract.

Thermo Scientific icap TQ ICP-MS: Typical limits of detection

Following documents shall be used for reference on quantities, units, prefixes and other technical vocabulary in this document:

Atomic Spectroscopy AA/ICP/ICPMS:

Analysis Repeatability of Trace and Major Elements in a Water Sample

Hach Method Spectrophotometric Measurement of Free Chlorine (Cl 2 ) in Finished Drinking Water

Automated determination of the uniformity of dosage in quinine sulfate tablets using a fiber optics autosampler

UNIVERSITI SAINS MALAYSIA. Second Semester Examination Academic Session 2004/2005. March KAA 502 Atomic Spectroscopy.

OPTIMIZING METALS SAMPLE PREP

110 Lowell Rd Hudson, NH USA Tel:

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek

Determination of Total Bromine and Iodine Emission Spectrometric Method (ICP-OES) EuSalt/AS

Accurate analysis of neptunium 237 in a uranium matrix, using ICP-QQQ with MS/MS

METHOD 7060A ARSENIC (ATOMIC ABSORPTION, FURNACE TECHNIQUE)

Product Descriptions and Offerings

OES - Optical Emission Spectrometer 2000

Hach Company TNTplus 835/836 Nitrate Method Spectrophotometric Measurement of Nitrate in Water and Wastewater

Determination of Impurities in Silica Wafers with the NexION 300S/350S ICP-MS

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

Direct Analysis of Photoresist Using Inductively Coupled Plasma Mass Spectrometry (ICP-MS) Application

Optimizing Analytical Performance in ICP-OES Applications

Determination of Nutrients. Determination of total phosphorus. Extraktion with aqua regia, reflux method. Introduction

Quality Control Procedures for Graphite Furnace AAS using Avanta Software

Accurate Mass Measurement for Intact Proteins using ESI-oa-TOF. Application Note. Donghui Yi and Christine Miller Agilent Technologies

Comparing Collision/Reaction Cell Modes for the Measurement of Interfered Analytes in Complex Matrices using the Agilent 7700 Series ICP-MS

Single particle analysis using the Agilent 7700x ICP-MS

NOTICE: This method: The laboratories have to study the instrumental conditions appropriate for their own instrumentation.

Low Level Phosphorus: A Method Comparison Study

Determination of challenging elements in ultrapure semiconductor grade sulfuric acid by Triple Quadrupole ICP-MS

Determination of ultratrace elements in photoresist solvents using the Thermo Scientific icap TQs ICP-MS

Using TOF for Screening and Quantitation of Sudan Red Colorants in Food Application

Ultra trace measurement of potassium and other elements in ultrapure water using the Agilent 8800 ICP-QQQ in cool plasma reaction cell mode

Automated, intelligent sample preparation: Integration of the ESI prepfast Auto-dilution System with the Thermo Scientific icap 7400 ICP-OES

Elemental Scientific. Stability. Elemental Scientific

BATTERY INDUSTRY STANDARD ANALYTICAL METHOD

Speciation of Bromine Compounds in Ozonated Drinking Water using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry

Not Just for Paint Chips Anymore. High Throughput, Open Vessel Microwave Digestion of Matrices Requiring Moderate Conditions

Determinations by Atomic Absorption Spectroscopy and Inductively Coupled Plasma-Atomic Emission

Using cold vapor generation atomic absorption to determine mercury impurities in pharmaceutical products

Elemental Scientific. Spike Recovery. Elemental Scientific

Standard Operating Procedure for the Analysis of Dissolved Inorganic Carbon CCAL 21A.1

Rapid determination of five arsenic species in polished rice using HPLC-ICP-MS

Dimethylglyoxime Method Method to 6.0 mg/l Ni TNTplus 856

High Sensitivity HPLC Analysis of Perchlorate in Tap Water Using an Agilent 6460 Triple Quadrupole LC/MS System

Mercury Determination in Lichen, BCR-482, Using the QuickTrace M-7600 CVAAS Mercury Analyzer

Automated Determination of PPQ Levels of Thorium in High Purity Copper

ALLOWAY METHOD OUTLINE

Product Safety Reference Manual. Book 5 - Laboratory Policies and Procedures C

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Direct Measurement of Trace Metals in Edible Oils by 7500cx ICP-MS with Octopole Reaction System

Cadion Method Method to 0.30 mg/l Cd TNTplus 852

Transcription:

Analysis of domestic sludge using the Agilent 4200 MP-AES Application note Environmental Authors Neli Drvodelic Agilent Technologies, Melbourne, Australia Introduction Managing the treatment and disposal of domestic sludge is an important activity and one that is highly regulated in many countries. After treatment, the effluent may be discharged leaving a mixture of water, organic solids and chemicals, nutrients, heavy metals, and inorganic ions. This sludge can be further treated and the resulting biosolids can then be applied to the land as a fertilizer, sent to landfill or incinerated. It is vital that the sludge or biosolids are tested and conform to regulatory levels in order to protect public health and the environment. The United States federal biosolids rule is contained in 40 CFR Part 503. The European Union Sludge Directive 86/278/EEC is expected to be revised as several Member States have enacted and implemented stricter limit values for heavy metals and set requirements for other contaminants. In this work, an Agilent 4200 MP-AES was used to determine major and minor elements in domestic sludge, following microwave digestion.

MP AES is a fast sequential, multielement analytical technique that uses a microwave-induced nitrogenbased plasma for sample excitation. Without needing expensive and hazardous gases such as acetylene, MP-AES increases lab safety and allows unattended operation, even for overnight runs. Sample throughput can be further enhanced with the use of the high capacity autosampler, the Agilent SPS 4. The 4200 MP-AES with MP Expert software uses a high number of automated parameters including pre-set methods, auto optimization, suggested wavelengths, and background correction. It has a simple yet powerful user interface and a reliable torch loader that automatically aligns the torch and connects gases for fast start up and reproducible performance. This application note describes the sample preparation procedure and analytical method used to analyze Zn, Mn, Cr, Ca, Fe, Cu and Mg in a domestic sludge standard reference material (SRM) using the Agilent 4200 MP-AES. Experimental Instrumentation All measurements were performed using an Agilent 4200 MP-AES fitted with a OneNeb nebulizer, double-pass glass cyclonic spray chamber and easyfit torch. Nitrogen can be supplied from bottled gas, Dewar or via the Agilent 4107 Nitrogen Generator (with air supplied from an air compressor). For this application, Dewar nitrogen was used. An Agilent SPS 4 autosampler was used to deliver samples to the instrument, allowing the system to be operated unattended. Method parameters are given in Table 1. Table 1. MP-AES method parameters Instrument Parameter Setting Nebulizer OneNeb Nebulizer flow rate Optimized Spay chamber Double-pass cyclonic glass Pump rate 15 rpm Sample pump tubing Orange/green Waste pump tubing Blue/blue Read time (s) 3 Number of replicates 3 Fast pump during uptake On Sample uptake delay (s) 50 Rinse time (s) 45 Stabilization time (s) 10 Background correction Auto Gas source Dewar nitrogen Sample and sample preparation Domestic Sludge SRM (SRM - 2781, NIST, Gaithersburg, MD, US) was used to validate the accuracy of the method. Approximately 0.5 g of the SRM sample was accurately weighed into a microwave vessel followed by the addition of 6 ml HNO 3 and 2 ml H 2 O 2. Acid digestion was performed in an UltraWAVE Single Reaction Chamber Microwave Digester. Heating conditions are given in Table 2. After cooling, the digested solution was transferred quantitatively to a volumetric flask and brought to a 50 ml volume with 18.2 MΩ deionized water. The final acid concentration was 12% HNO 3. Table 2: Parameters used for microwave digestion Parameter Setting Ramp (min) 10 Temp ( C) 150 Hold (min) 5 Ramp (min) 10 Temp ( C) 230 Hold (min) 10 Total (min) 30 2

Calibration standards Single element stock solutions (Agilent Technologies) were used to prepare the multi-element calibration standards. One set of multi-element standards was used for the calibration. All working standards were prepared in 12% HNO 3 and HCl. No modifier or ionization buffers were required. Wavelength selection and calibration range Details of wavelength selection and nebulizer flow rate are given in Table 3. MP-AES features continuous wavelength coverage and the MP Expert software includes an extensive wavelength database that allows the selection of wavelengths suited to the concentration range required for the analysis. For example, in this application, the less sensitive Mg 383.829 nm line was selected over the more sensitive Mg 285 nm line because it has a large dynamic range, meets the detection limit requirements of the application, and is free from spectral interferences. Table 3. Element, wavelength and nebulizer flow Element Wavelength (nm) Nebulizer Flow (L/min) Zn 213.857 0.45 Mn 403.449 0.9 Cr 425.433 0.9 Ca 445.478 0.5 Fe 373.486 0.5 Cu 324.754 0.7 Mg 383.829 0.9 Results and discussion Calibration In addition to minimizing spectral interferences, all wavelengths were selected to provide the widest dynamic range. Each element was calibrated using a three point calibration. All calibration curves were linear, except for Ca 455.478 nm, which was rational fit. The curves had a correlation factor greater than 0.999 and less than 10% calibration error on each calibration point. The calibration curve for Mg 383.829 nm (Figure 1) is a typical example, showing excellent linearity across the calibration range. Figure 1. Calibration curve for Mg 383.829 nm. Table 4 summarizes the calibration standard concentration range and correlation coefficients for all 7 elements. As the working range of MP-AES far exceeds that of FAAS, further dilution of the sample digest was not required to measure all of the elements of interest. Reducing the number of sample dilution steps improves productivity and reduces the risk of sample contamination. Table 4. Calibration standard concentration range and correlation coefficients Element / Wavelength (nm) Standard Conc. Range (mg/l) Linear Correlation Coefficient - r Zn 213.857 0-10 0.99987 Mn 403.449 0-10 0.99994 Cr 425.433 0-10 0.99964 Ca 445.478 0-250 0.99999 Fe 373.486 0-250 0.99988 Cu 324.754 0-100 0.99998 Mg 383.829 0-100 1.00000 Sample analysis Recoveries of the domestic sludge SRM are based on the average of 3 replicate digestions over separate analyses. The mean concentration, standard deviation (SD), and recovery was calculated for each analyte, as shown in Table 5. The results obtained with the method were in good agreement with the SRM values (96 103%), verifying the method. 3

Table 5. MP-AES recovery of elements in NIST 2781 domestic sludge SRM. Results are compared to the reference leach values. Element/ Wavelength (nm) Measured conc in sample (mg/l) SD Leachable mass fraction (mg/kg) Recovery in sample (%) Zn 213.857 1132.8 94.6 1120 101.1 Mn 403.449 768.3 21.7 745 103.1 Cr 425.433 142.9 3.68 143 99.9 Ca 445.478 35145.3 716.5 36440 96.4 Fe 373.486 25108.0 232.6 24300 103.3 Cu 324.754 599.1 15.3 601 99.7 Mg 383.829 4842.0 252.6 4850 99.8 Method Detection Limits Method Detection Limits (MDL) were determined using three sigma of ten replicate measurements of the matrix blank solution, then multiplying by the dilution factor to calculate the MDL in the original sample. These MDLs were acquired using a method conditions suitable for routine sample analysis rather than highly optimized conditions. Consequently, they are not best-possible detection limits but are more than sufficient for the method requirements. The results are shown in Table 6. Table 6. Method Detection Limits in the original sample (mg/kg). Element Wavelength (nm) MDL (mg/kg) Zn 213.857 0.25 Mn 403.449 0.03 Cr 425.433 0.03 Ca 445.478 1.03 Fe 373.486 0.88 Cu 324.754 0.43 Mg 383.829 0.20 Long term stability The domestic sludge SRM was analyzed every 10 samples over 12 hours of continuous measurement. Excellent stability was achieved over this period as shown in Figure 2. Average recoveries for most elements were within ± 2%. The long term measurement precision over the full 12 hours was less than 2% RSD (Table 7), demonstrating the suitability of the 4200 MP-AES for routine measurement of metals in domestic sludge samples. Figure 2. Long-term stability plot. <2.0% RSD over 12 hours analysis of domestic sludge SRM. Table 7. Long-term precision and average recovery over 12 hours continuous measurement of the domestic sludge SRM. Element/ Wavelength %RSD Average Recovery (%) (nm) Zn 213.857 0.8 99.2 Mn 403.449 2.0 98.0 Cr 425.433 1.9 98.4 Ca 445.478 1.4 98.5 Fe 373.486 1.7 98.9 Cu 324.754 1.1 98.4 Mg 383.829 1.1 99.0 Potential cost savings with the 4200 MP-AES The example given in Figure 3 is intended to demonstrate the reduction in running costs and thus potential savings of the MP-AES, compared to operating a flame atomic absorption spectrometer. Figure 3. Potential cost savings with MP-AES compared to FAAS over time* *This example is intended to help you compare the running costs and savings of the MP-AES vs. flame AA. The applied formulas and parameters are correct to the best of our knowledge, but we cannot guarantee the results. Savings may vary depending on factors such as local gas and electricity costs, operator costs, number and types of elements. For this calculation, operator labor costs were set to USD 25 per hour and electricity costs were set to USD 0.2 per kw. 4

Operating an MP-AES in place of a FAAS over a 7-year evaluation period could lead to savings of more than USD300K as shown in Figure 3. The cost-comparison was based on the following criteria: An FAAS fitted with an air compressor, autosampler, and 1 year of consumables, In addition to analytical performance advantages, MP-AES is considerably more cost-effective over the long term than FAAS - an important consideration for any lab looking to invest in new or replacement instrumentation. An MP-AES fitted with an air compressor, SPS 4 autosampler and 1 year of consumables Seven elements measured under method conditions Based on the analysis of 300 samples per week Conclusions The Agilent 4200 MP-AES is ideally suited to the analysis of major and trace elements in domestic sludge following a simple microwave digestion sample preparation procedure. Excellent recoveries of the standard reference material were achieved, with good precision. Instrument robustness was demonstrated with exceptional stability over 12 hours without the need to recalibrate. The 4200 MP-AES offers multiple benefits over FAAS including: Higher performance with fast sequential operation, lower detection limits and wider dynamic range, meaning higher sample throughput and fewer manual dilutions. Improved safety and reduced running costs with the use of nitrogen to generate the plasma. Simplified workflow with no need to change and optimize lamps, and no need for complicated element specific sample preparation with addition of modifiers or buffers. 5

www.agilent.com/chem Agilent shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance or use of this material. Information, descriptions, and specifications in this publication are subject to change without notice. Agilent Technologies, Inc. 2015 Published September 14 2015 Publication number: 5991-6239EN