Scintillators General Characteristics

Similar documents
Scintillation Detectors Particle Detection via Luminescence. Kolanoski, Wermes

Chapter 4 Scintillation Detectors

PHYS 3446 Lecture #12

Scintillation Detectors Particle Detection via Luminescence

SCINTILLATION DETECTORS AND PM TUBES

EEE4106Z Radiation Interactions & Detection

Platinum resistance. also wirewound versions. eg

hν' Φ e - Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous?

Lecture 16 Light transmission and optical detectors

Radiation Detectors. How do we detect ionizing radiation? What are these effects? Types of Ionizing Radiation Detectors

Scintillation Detectors

Introduction to scintillators

Scintillation Detectors

DETECTORS. I. Charged Particle Detectors

Nuclear Physics and Astrophysics

Gamma Spectroscopy. References: Objectives:

Week 6: Ch. 8 Scintillation Counters

Scintillators Definitions - 1!

Nuclear Physics Laboratory. Gamma spectroscopy with scintillation detectors. M. Makek Faculty of Science Department of Physics

05 - Scintillation detectors

Radionuclide Imaging MII Detection of Nuclear Emission

Chemistry Instrumental Analysis Lecture 19 Chapter 12. Chem 4631

Contents. Charged Particles. Coulomb Interactions Elastic Scattering. Coulomb Interactions - Inelastic Scattering. Bremsstrahlung

Radiation Detection and Measurement

Radioactivity. Lecture 6 Detectors and Instrumentation

Radioactivity and Ionizing Radiation

Scintillation Detector

Scintillation detectors

Because light behaves like a wave, we can describe it in one of two ways by its wavelength or by its frequency.

Radiation Dose, Biology & Risk

Detector technology. Aim of this talk. Principle of a radiation detector. Interactions of gamma photons (gas) Gas-filled detectors: examples

Copyright 2008, University of Chicago, Department of Physics. Experiment VI. Gamma Ray Spectroscopy

Energetic particles and their detection in situ (particle detectors) Part II. George Gloeckler

Analysis of γ spectrum

Chemical Engineering 412

Lecture # 3. Muhammad Irfan Asghar National Centre for Physics. First School on LHC physics

Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy. Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy

Calorimetry I Electromagnetic Calorimeters

Inorganic Scintillators

Gamma and X-Ray Detection

GLOSSARY OF BASIC RADIATION PROTECTION TERMINOLOGY

Quality Assurance. Purity control. Polycrystalline Ingots

Scintillators 1. YEAR, I. CYCLE. AUTHOR: BPhys. Manja Ščetinec ADVISOR/MENTOR: Prof. Boštjan Golob

EE 5344 Introduction to MEMS CHAPTER 5 Radiation Sensors

Particle Energy Loss in Matter

Radiation (Particle) Detection and Measurement

Absorption spectrometry summary

Single Photon detectors

Neutron Detection. n interactions with matter n detection High/low energy n detectors

Quantum Mechanics. An essential theory to understand properties of matter and light. Chemical Electronic Magnetic Thermal Optical Etc.

Radiation Detection for the Beta- Delayed Alpha and Gamma Decay of 20 Na. Ellen Simmons

Inorganic scintillators. Geometries and readout

General Information. Individual Study Projects. Muon Lifetime Experiment. Today s Agenda. Wednesday: We have a few more slots to fill

The fast light of CsI(Na) crystals

Gamma-ray spectroscopy with the scintillator/photomultiplierand with the high purity Ge detector: Compton scattering, photoeffect, and pair production

III. Energy Deposition in the Detector and Spectrum Formation

PARTICLES REVELATION THROUGH SCINTILLATION COUNTER

(10%) (c) What other peaks can appear in the pulse-height spectrum if the detector were not small? Give a sketch and explain briefly.

Photon Instrumentation. First Mexican Particle Accelerator School Guanajuato Oct 6, 2011

GAMMA RAY SPECTROSCOPY

The Compton Effect. Martha Buckley MIT Department of Physics, Cambridge, MA (Dated: November 26, 2002)

5-A / 9, WEA, Sat Nagar, Karol Bagh New Delhi Web:

SCINTILLATION DETECTORS & GAMMA SPECTROSCOPY: AN INTRODUCTION

Photons in the universe. Indian Institute of Technology Ropar

Gamma-ray spectroscopy with the scintillator/photomultiplierand with the high purity Ge detector: Compton scattering, photoeffect, and pair production

Detection and measurement of gamma-radiation by gammaspectroscopy

1.4 The Tools of the Trade!

Ionization Detectors

The interaction of radiation with matter

Radiation Detection. 15 th Annual OSC Readiness Training Program.

Interaction of Ionizing Radiation with Matter

Neutrino Helicity Measurement

Advantages / Disadvantages of semiconductor detectors

Total probability for reaction Yield

Particle Energy Loss in Matter

Experimental Particle Physics

Stellar Astrophysics: The Interaction of Light and Matter

The Mössbauer Effect

Chapter 11: Neutrons detectors

Unit 2. Instrumentation. Experts Teaching from Practical Experience

Queen s University PHYS 352

Experiment 6 1. The Compton Effect Physics 2150 Experiment No. 6 University of Colorado

Dedicated Arrays: MEDEA GDR studies (E γ = MeV) Highly excited CN E*~ MeV, 4 T 8 MeV

An Introduction to Diffraction and Scattering. School of Chemistry The University of Sydney

MS482 Materials Characterization ( 재료분석 ) Lecture Note 4: XRF

David B. Cassidy. Department of Physics and Astronomy, University of California, Riverside, USA. Varenna, July 09

Time-of-Flight PET using Cherenkov Photons Produced in PbF 2

Seminar talks. Overall description of CLAS12 (Jefferson Lab) MAPS. Talks on Feb. 6 th, (Contact JR) (Contact TS)

Gamma Ray Spectroscopy, Using NaI(Tl) Detectors. Department of Physics The University of Hong Kong

Proportional Counters

Time-Resolved Liquid Scintillation Counting

Trace Element Analysis of Geological, Biological & Environmental Materials By Neutron Activation Analysis: An Exposure

Interaction of particles with matter - 2. Silvia Masciocchi, GSI and University of Heidelberg SS2017, Heidelberg May 3, 2017

Chapter Seven (Nuclear Detectors)

1.5. The Tools of the Trade!

Particle Detectors and Quantum Physics (2) Stefan Westerhoff Columbia University NYSPT Summer Institute 2002

Detekce a spektrometrie neutronů. neutron detection and spectroscopy

Absolute activity measurement

Electron and electromagnetic radiation

Lecture 3 - Compton Scattering

Transcription:

Scintillators General Characteristics Principle: de/dx converted into visible light Detection via photosensor [e.g. photomultiplier, human eye ] Main Features: Sensitivity to energy Fast time response Pulse shape discrimination Requirements High efficiency for conversion of excitation energy to fluorescent radiation Transparency to its fluorescent radiation to allow transmission of light Emission of light in a spectral range detectable for photosensors Short decay time to allow fast response

Scintillators basic counter setup 1. An incident photon or particle ionizes the medium. 2. Ionized electrons slow down causing excitation. 3. Excited states immediately emit light. 4. Emitted photons strike a light-sensitive surface. 5. Electrons from the surface are amplified. 6. A pulse of electric current is measured. Scintillation materials: Photosensors: Inorganic crystals Organic scintillators Polymeres (plastic scintillators) Photomultipliers Micro-Channel Plates Hybrid Photo Diodes Visible Light Photo Counter Silicon Photomultipliers

Scintillation counters loss of energy through change in vibrational states Luminescence: Emission of photons (visible light, UV, X-ray) after absorption of energy. Scintillation: Emission of photons following the excitation of atoms and molecules by radiation. Fluorescence: Emission of light by a substance that has absorbed light or another electromagnetic radiation of a different wave length. In most cases the emitted light has a longer wavelength. The emission follows shortly after ~ 10 ns. Phosphorescence: Similar to Fluorescence, however the re-emission is not immediate. The transition between energy levels and the photon emission is delayed (ms up to hours)

Inorganic crystals Materials: Sodium iodide (NaI) Cesium iodide (CsI) Barium fluoride (BaF 2 ) Mechanism: Energy deposition by ionization Energy transfer to impurities Radiation of scintillation photons Time constants: Fast: recombination from activation centers [ns μs] Slow: recombination due to trapping [ms s] Energy bands in impurity activated crystals showing excitation, luminescence, quenching and trapping

Inorganic crystals time constants

Inorganic crystals light output scintillation spectrum for NaI and CsI strong temperature dependence [in contrast to organic scintillators]

Scintillation in liquid nobel gases

Inorganic scintillators - properties The time for 1/e of the atoms to remain excited is the characteristic decay time τ

Inorganic scintillators - properties Numerical examples: NaI(Tl) PbWO 4 λ max = 410 nm; h ν = 3 ev photons/mev = 40000 τ = 250 ns λ max = 420 nm; h ν = 3 ev photons/mev = 200 τ = 6 ns Scintillator quality: Light yield ε SC fraction of energy loss going into photons NaI(Tl): 40000 photons; 3 ev/photon ε SC = 4 10 4 3 ev/10 6 ev = 12% PbWO 4 : 200 photons; 3 ev/photon ε SC = 2 10 2 3 ev/10 6 ev = 0.06% [for 1 MeV particle] Only a few percent of the deposited energy is transferred into light. The remaining energy is used up be ionization, etc. h = 0.41 10-14 [ev/hz]

Photon statistics Typical problem Gamma rays of 450 kev are absorbed with 12% efficiency. Scintillator photons with average 2.8 ev produce photoelectrons 15% of the time. What is the energy to produce a measurable photoelectron? How does this compare to a gas detector? Answer The total energy of scintillation is 450 0.12 = 54 kev - 5.4 10 4 / 2.8 = 1.93 10 4 photons produced - 1.93 10 4 0.15 = 2900 photoelectrons produced The equivalent value for the scintillator is: - 450 kev/2900 = 155 ev/pe mean value in gas = 30 ev/ip

Band structure Impurities in the crystal provide energy levels in the band gap. hν conduction band impurity excited states impurity ground state valence band Charged particles excites electrons to states below the conduction band. Deexcitation causes photon emission. Crystal is transparent at photon frequency. Impurities improve visible light emission

Organic scintillators Aromatic hydrocarbon compounds: e.g. Naphtalene [C 10 H 8 ] Antracene [C 14 H 10 ] Stilbene [C 14 H 12 ] Very fast! [decay times of 0 ns] Scintillation is based on electrons of the C=C bond Scintillation light arises from delocalized electrons in π-orbitals Transition of free electrons

Organic scintillators excited rings singlet states triplet states π-bonds are most common in aromatic carbon rings. Excited states radiate photons in the visible and UV spectra. Fluorescence is the fast component (S 1 S 0 <10-8 s) Phosphorescence is the slow component (T 0 S 0 >10-4 s) π-electronic energy levels of an organic molecule. S 0 is the ground state. S 1, S 2, S 3 are excited singlet states. T 1, T 2, T 3 are excited triplet states. S 00, S 01, S 10, S 11 etc. are vibrational sublevels.

Plastic scintillators Organic scintillators can be mixed with polystyrene to form a rigid plastic

Organic scintillators - properties

Wavelength shifting Principle: Absorption of primary scintillation light Re-emission at longer wavelength Schematics of wavelength shifting principle Adapts light to spectral sensitivity of photosensor Requirements: Good transparency for emitted light

Scintillators - comparison Inorganic Scintillators Advantages high light yield [typical ε SC 0.13] high density [e.g. PbWO 4 : 8.3 g/cm 3 ] good energy resolution Disadvantages complicated crystal growth large temperature dependence Organic Sintillators Advantages very fast easily shaped small temperature dependence pulse shape discrimination possible Disadvantages lower light yield [typical ε SC 0.03] radiation damage

Oscilloscope traces from scintillation counters Plastic scintillator 10 nsec / division Inorganic crystal, NaI 5000 nsec / division Longer time scale for fluorescence to occur

Scintillation counters - setup Scintillator light to be guided to photosensor light guide [plexiglas, optical fibers] light transfer by total internal reflection [ may be combined with wavelength shifter] Liouville s Theorem: Complete light transfer impossible as Δx Δθ = const. [limits acceptance angle] Use adiabatic light guide like fish tail ; appreciable energy loss

Liouville s Theorem Consider a phase space element for a photon in a light guide x = transverse coordinate p = n sin α = angular divergence isotropic light emission Liouville s theorem says Δx 1 Δp 1 = Δx 2 Δp 2 2 Δx 1 n sin α 1 = 2 Δx 2 n sin α 2 ssssss αα 1 = xx 2 xx 1 ssssss αα 2 ssssss αα 2 = ssssss φφ + 90 0 θθ cc ssssss αα 2 = cccccc φφ θθ cc = 1 ssssss 2 φφ θθ cc ssssss αα 2 1 ssssss 2 θθ cc for small taper angles ssssss αα 2 1 1 nn 2 then ssssss αα 1 xx 2 xx 1 1 1 nn 2 for Δx 1 = Δx 2 and n=1.5 ssssss αα 1 = 0.75 There will be some light losses even in the case of equal dimensions

Photomultiplier tube A photomultiplier tube (phototube, PMT) combines a photocathode and series of dynodes. Photocathode: UV detection (alkali compound, Cs-I, Cs-Te), visible light (bialkali compound, Sb-Rb-Cs, Sb-K-Cs), visible light to IR (semiconductors, GaAsP, InGaAs) Dynodes: Electrons can be multiplied by interaction with surface (emitter: BeO, GaP or metal substrate: Ni, Fe, Cu) The high voltage is divided between the dynodes. Dynodes typically operate at around 100 V. Output current is measured at the anode. Sometimes at the last dynode

Photomultiplier - Photocathode γ-conversion via photoeffect 3-step process: Electron generation via ionization Propagation through cathode Escape of electron into vacuum Quantum Efficiency Q.E. 10-30% conduction band hν e Fermi energy E G vacuum energy E A ψ Percent of light which passes valence band Wavelength of light

Photomultiplier Dynode Chain Multiplication process: Electrons accelerated towards dynode Further electrons produced avalanche Secondary emission coefficient: δ = #(e- produced) / #(e- incoming) = 2 10 #dynodes n = 8 15 Gain factor: G = δ n = 10 6-10 8

Voltage divider Current, I (amperes) 4 Ω = R 1 Battery U batt = 9 Volts + a - Voltmeter 2 Ω = R 2 here Ohm s law: UU = RR II or II = UU RR current in circuit: II = UU bbbbbbbb = 9 VV = 1.5 AA RR 1 + RR 2 6 Ω UU aaaaaaaaaaaa RR2 = II RR 2 = 1.5 AA 2 Ω = 3 VV b The 9 V battery is divided in 3 V and 6 V, now accessible with this circuit.

Photomultiplier Energy Resolution Energy resolution influenced by: Linearity of PMT: at high dynode current possible saturation by space charge effects; I A nγ for 3 orders of magnitude possible Photoelectron statistics: given by Poisson statistics. n e is given by de/dx PP nn nn ee = nn ee nn ee nn ee nn! σσ nn nn = 1 nn ee nn ee = dddd dddd ppppppppppppp ηη QQ. EE. MMMMMM For NaI(Tl) and 10 MeV photon photons/mev = 40000 light collection efficiency η = 0.2 quantum efficiency Q.E. = 0.25 n e = 20000 σ n /<n> = 0.7% Secondary electron fluctuations: PP nn δδ = δδnn ee δδ nn! σσ nn nn = 1 δδ

Pulse shape discrimination Pulse shape discrimination (PSD) in organic scintillators are used in particularly liquid scintillators (NE213 / BC501A) PSD is due to long-lived decay of scintillator light caused by high de/dx particle neutron scatter interaction events causing proton recoil

Neutron detectors Neutron detectors do not detect neutrons but products of neutron interaction! James Chadwick, Nature 132 (1932) 3252

General detection principle Neutron detectors do not detect neutrons but products of neutron interaction! Detection of a neutron is a sequential process 1. Interaction of the incident neutron: neutron transport 2. Transport of secondary particles to or within sensing elements hadron, ion, photon transport 3. Primary ionization by secondary particles 4. Conversion to optical photons, gas amplification: Transport of electrons and optical photons 5. Conversion to electrical signal external converter (radiator) converter = detector

Interaction of neutrons with matter Neutron detectors can only be detected after conversion to charged particles or photons: Elastix scattering: A X(n,n) A X recoil nucleus A X Z+ Inelastic scattering: A X(n,n γ) A X recoil nucleus A X Z+, e - Radiative capture: A X(n,γ) A+1 Y e - Neutron emission: A X(n,2n) A-1 Y radioactive daughter Charged-particle emission: A X(n,lcp) A Y (lcp = p, d, t, α), recoil nucleus Fission: n + A X A1 X 1 + A2 X 2 + νn fission fragments A Y Z+ cross section relevant for neutron detection