Fabric Corsica. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M111250/16

Similar documents
Curtain fabric type Ace Manufacturer Kvadrat A/S

Fabric UDINE. Measurement of sound absorption according to EN ISO 354. Test Report No. M102794/32

Fabric Dazzle 6086 Manufacturer Carnegie Fabrics

Fabric STREAMER pro. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M111250/04

Fabric Medley Manufacturer Gabriel A/S

Roller blind fabric PRIMACOUSTIC R

Fabric REFLECTACOUSTIC

Fabric Zetacoustic. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M102794/07

Fabric TWIST MELANGE Manufacturer Gabriel A/S

Fabric XPRESS + PU-foam Manufacturer Gabriel A/S

Fabric Sport. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M102794/02

Fabric ALEX. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M102794/09

Fabric Umbria III R. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M102794/13

Fabric VELOS STRATO. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M102794/10

stylegreen Iceland Moss / Reindeer Moss of the company FlowerArt

Renolit stretch ceilings

Fabric Medley Manufacturer Gabriel A/S

Fabric HUSH Manufacturer Gabriel A/S

Fabric RUNNER Manufacturer Gabriel A/S

Fabric EVENT SCREEN Manufacturer Gabriel A/S

Fabric XPRESS Manufacturer Gabriel A/S

Sound insulation of planted noise barriers

Laboratory for Acoustics. Determination of the sound absorption (reverberation room method) of curtains, manufacturer Vescom BV

MEASUREMENTS OF SOUND ABSORPTION TIMBERCRETE

Report. P.O. Box 70 NL 5700 AB Deurne The Netherlands Report number: A E-RA Date: 12 februari 2014 TS/TS/JW/A E-RA

TFI Report Sound Absorption Impact Sound Insulation

Test Report. RI Acoustic Lab. Measurement of Sound Absorption Coefficient for RockDelta NoiStop Noise Barrier. 20 Feb. 07

REPORT ON THE DETERMINATION OF SOUND ABSORPTION COEFFICIENTS OF WOVEN IMAGE ECHO PANEL 7MM TESTED WITH A 20MM AIR GAP IN A REVERBERATION ROOM.

TFI Report Sound Absorption Impact Sound Insulation

LABORATORY MEASUREMENTS OF THE SOUND ABSORPTION OF CLASSICTONE 700 ASTM C Type E Mounting. Test Number 2

LABORATORY MEASUREMENTS OF THE SOUND ABSORPTION COEFFICIENTS OF OSCAR EVO-PANELS

Laboratory for Acoustics. Determination of the sound absorption (reverberation room method) of Airpanel, manufacturer Texdecor

REPORT ON THE DETERMINATION OF SOUND ABSORPTION COEFFICIENTS OF WOVEN IMAGE ECHO PANEL 24MM TESTED WITH NO AIR GAP MEASURED IN A REVERBERATION ROOM.

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6986/ARL-SA6987 Revision 0 ARL

DELTA Test Report. Measurement of sound absorption coefficient for 15 mm Fraster felt Plus acoustic panels with mounting depth 45 mm

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6266/ARL-SA6274 Revision 0 ARL

Laboratory for Acoustics

Testing Procedure: AS ISO

DELTA Test Report. Measurement of Sound Absorption for AqFlex ON, one Sample as a discrete Object. Performed for Flex Acoustics

Measurement of sound absorption coefficient for Fraster felt SpaceCover

DELTA Test Report. DANAK TEST Reg. no Measurement of Sound Absorption Coefficient for Kvadrat Soft Cells Wall Panel Type Time

Calcul des coefficients d'absorption alpha sabine

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6712/ARL-SA6713 Revision 0 ARL

Measurement of Acoustic Properties of light weight concrete SL-Deck

ROLLEASE ACMEDA ACOUSTICAL PERFORMANCE TEST REPORT

Report. Laboratory for Acoustics

TFI Report Sound Absorption Impact Sound Insulation

TFI Report Sound Absorption Impact Sound Insulation

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6956 Revision 1 ARL

REPORT N CR

Consultancy Report Ref: 9383-R01

LABORATORY MEASUREMENT OF SOUND ABSORPTION OF SONOGLASS SPRAY-ON TREATMENT IN THREE CONFIGURATIONS

Report. Laboratory for Acoustics Determination of the sound absorption (reverberation room method) of different wired mats, manufacturer Rockwool

Laboratory for Acoustics

Technical Report. Project. The Laboratory Determination of The Random Incidence sound Absorption Coefficient of VertiQ Panels.

A L I O N Technical Center. Test Report. Port Coquitlam, British Columbia, Canada

A L I O N Technical Center. Test Report

RIVERBANK ACOUSTICAL LABORATORIES

ISO 354 INTERNATIONAL STANDARD. Acoustics Measurement of sound absorption in a reverberation room

Page 1 of 10 pages Appendix, 5 pages Report no.: P Glostrup, October 12th 2012 Project: Claimant:

REPORT. Client. Test object. Date of testt. Results. Rönnåsgatan 5B Ulricehamn. (7 appendices) content of the

Laboratory for Acoustics. Determination of the sound insulation of sliding door constructions, manufactured by Metaflex

RIVERBANK ACOUSTICAL LABORATORIES

Sound Absorption Test Intertek. kraft paper softwall + softblock modular system. m o l o d e s i g n, l t d

R & D AKUSTIKA * SIA. Test Report of laboratory Sound Insulation measurements Nr. 569 / 2011 AL 8.4. CUSTOMER: AEROC AS (Estonia)

Development of a small-scale reverberation room

Report. Laboratory for Acoustics

Summary. The basic principles of the simulation technique SERT

LABORATORY MEASUREMENTS OF THE REDUCTION OF TRANSMITTED IMPACT NOISE PANETTI OVERLAID BY CONCRETE FLOORING

ISO INTERNATIONAL STANDARD

Paseo Recoletos, nº Madrid TEST REPORT

TFI Report Impact Sound Insulation

Modeling Measurement Uncertainty in Room Acoustics P. Dietrich

TFI Report Impact Sound Insulation

Certificate Sound reduction of building elements

Micro-perforated sound absorbers in stretched materials

Technical Note. Measurement of Sound Absorption for Flex Acoustics AqTube. Performed for Flex Acoustics. TC Project no.: T Page 1 of 7

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

EXPERIMENTAL VERIFICATION OF THE EUROPEAN METHODOLOGY FOR TESTING NOISE BARRIERS IN SITU: SOUND REFLECTION

ISO INTERNATIONAL STANDARD. Acoustics Acoustic insulation for pipes, valves and flanges

Design and Acoustics Brought into Harmony

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

Ceiling Diffuser. Type ADLR with circular face. Type ADLR-Q with square face 2/16/EN/8

THE ACOUSTIC IMPEDANCE MEASUREMNET SYSTEM USING TWO MICROPHONES

Evaluation of standards for transmission loss tests

ISO INTERNATIONAL STANDARD

Benefits of Reduced-size Reverberation Room Testing

VK2 volume flow controller Overview

The diagram below. to the by the. outlet into. calculation. Since TRANSMISSION VIA STRUCTURE. Vibration Via Supports Duct Breakout

Chalmers Publication Library

Determination of sound absorption coefficient in impedance tubes according to ISO (2 appendices)

A suggested method to be used to measure scattering coefficients of full scale samples.

EUROVENT 8/12 SOUND TEST METHOD FOR DUCTED FAN COIL UNITS. FCP 2008 testing procedures FCP acoustical test method pag. 1

Philips luminous textile with. Specifications sheet luminous textile panel

Using an ambisonic microphone for measurement of the diffuse state in a reverberant room

ODEON APPLICATION NOTE Calibration of Impulse Response Measurements

INVESTIGATIONS INTO THE PERFORMANCE OF THE REVERBERATION CHAMBER OF THE INTEGRATED ACOUSTICS LABORATORY. A Thesis Presented to The Academic Faculty

COMPARISON OF THE METHODS TO CALIBRATE THE DIFFUSE FIELD SENSITIVITY OF LABORATORY STAND- ARD MICROPHONE

CIRCO. Sound-attenuating transfer unit QUICK FACTS

Users Manual. Marshall Day Acoustics. Double Panels Contact 33 Details Marshall Day 37.8 Acoustics PO Box

Transcription:

Müller-BBM GmbH Robert-Koch-Str. 11 82152 Planegg bei München Telephone +49(89)85602 0 Telefax +49(89)85602 111 www.muellerbbm.de M. Eng. Philipp Meistring Telephone +49(89)85602 228 Philipp.Meistring@mbbm.com 2017-04-24 Fabric Corsica Measurement of sound absorption in a reverberation room according to EN ISO 354 Test Report No. M111250/16 Client: Consultant: Accredited testing laboratory according to ISO/IEC 17025 Vescom B.V. Sint Jozefstraat 20 NL-5753 AV Deurne Date of report: 2017-04-24 Delivery date of test objects: 2017-04-21 Date of test: 2017-04-24 Total number of pages: M. Eng. Philipp Meistring Jan-Lieven Moll In total 14 pages, thereof 6 pages text, 2 pages Appendix A, 2 pages Appendix B and 4 pages Appendix C. Müller-BBM GmbH HRB Munich 86143 VAT Reg. No. DE812167190 Managing directors: Joachim Bittner, Walter Grotz, Dr. Carl-Christian Hantschk, Dr. Alexander Ropertz, Stefan Schierer, Elmar Schröder

Table of contents 1 Task 3 2 Basis 3 3 Test object and test assembly 3 3.1 Test object 3 3.2 Test assembly 4 4 Execution of the measurements 5 5 Evaluation 5 6 Measurement results 5 7 Remarks 6 Appendix A: Appendix B: Appendix C: Test certificates Photos Description of test method, test facility and test equipment 2017-04-24 Page 2

1 Task On behalf of the company Vescom B.V., NL-5753 AV Deurne, the sound absorption of the fabric Corsica had to be measured according to EN ISO 354 [1] in the reverberation room. The fabric was tested as a curtain in a flat and a folded arrangement with a distance of 150 mm to the reflective wall. 2 Basis This test report is based on the following documents: [1] EN ISO 354: Acoustics - Measurement of sound absorption in a reverberation room. 2003-05 [2] EN ISO 11654: Acoustics Sound absorbers for use in buildings Rating of sound absorption. 1997-04 [3] ASTM C 423-17: Standard Test Method for Sound Absorption and Sound Absorption Coefficients by the Reverberation Room Method. Revision: 17. February 2017. [4] ISO 9613-1: Acoustics; Attenuation of sound during propagation outdoors; part 1: calculation of the absorption of sound by the atmosphere. June 1993 [5] EN 29053: Acoustics Materials for acoustical applications Determination of airflow resistance. March 1993 3 Test object and test assembly 3.1 Test object The tested material is described by the manufacturer as follows: - curtain fabric Corsica The following parameters were determined by the testing laboratory: - thickness: t = 0.35 mm - specific airflow resistance acc. to EN 29053 [5]: R s = 255 Pa s/m - area-related mass: m = 107 g/m² 2017-04-24 Page 3

3.2 Test assembly The installation of the test objects was carried out by employees of the test laboratory in the reverberation room of Müller-BBM. The test objects were installed in a flat and a folded arrangement. Both arrangements were mounted as follows: - clear distance to the reflective wall 150 mm - fixed directly underneath the ceiling on a metal rail (h = 50 mm) - measurement without enclosing frame - visible side corresponding to marking by the manufacturer faced to the reverberation room The mounting details for the tested arrangements are as follows: a) flat arrangement - mounting type G-150 acc. to EN ISO 354 [1], section 6.2.1 and Appendix B of EN ISO 354 [1] - one curtain width x height = 3500 mm x 3000 mm - total dimensions of the test surface (starting at the lower edge of the metal rail) width x height = 3500 mm x 2950 mm b) folded arrangement - mounting type following G-150 acc. to EN ISO 354 [1] - 100 % fabric addition - two curtains: one curtain width x height = 3520 mm x 3000 mm and one curtain width x height = 3500 mm x 3000 mm, 20 mm overlap - total dimensions of the test surface (starting at the lower edge of the metal rail) width x height = 3500 mm x 2950 mm Appendix B contains photos of the tested arrangements. 2017-04-24 Page 4

4 Execution of the measurements The measurements were executed and evaluated according to EN ISO 354 [1]. The test procedure, the test stand and the test equipment used for the measurements are described in Appendix C. 5 Evaluation The sound absorption coefficient α S was determined in one-third octave bands between 100 Hz and 5000 Hz according to EN ISO 354 [1]. In addition to the sound absorption coefficients the following characteristic values were determined according to EN ISO 11654 [2]. - practical sound absorption coefficient α p in octave bands - weighted sound absorption coefficient α w as single value: The weighted sound absorption coefficient α w is determined from the practical sound absorption coefficients α p in the octave bands of 250 Hz to 4000 Hz. According to ASTM C 423-17 [3] the following characteristic values were determined: - noise reduction coefficient NRC as single value: Arithmetical mean value of the sound absorption coefficients in the four onethird octave bands 250 Hz, 500 Hz, 1000 Hz and 2000 Hz; mean value rounded to 0.05. - sound absorption average SAA as single value: Arithmetical mean value of the sound absorption coefficients in the twelve onethird octave bands between 250 Hz and 2500 Hz; mean value rounded to 0.01. 6 Measurement results The sound absorption coefficients α S in one third-octave bands, the practical sound absorption coefficients α p in octave bands and the single values α w, NRC and SAA are indicated in the test certificates in Appendix A. 2017-04-24 Page 5

7 Remarks The test results exclusively relate to the investigated subjects and conditions described. M. Eng. Philipp Meistring This test report may only be published, shown or copied as a whole, including its appendices. The publishing of excerpts is only possible with prior consent of Müller-BBM. 2017-04-24 Page 6

Sound absorption coefficient ISO 354 Measurement of sound absorption in reverberation rooms Client: Vescom B.V., Sint Jozefstraat 20, 5753 AV Deurne, Netherland Test specimen: Fabric Corsica Mounting type G-150, flat arrangement Curtain fabric: curtain fabric Corsica area-related mass m" = 107 g/m² airflow resistance R S = 255 Pa s/m thickness t = 0,35 mm Tested arrangement: mounting type G-150 acc. to EN ISO 354, without enclosing frame one curtain width x height = 3500 mm x 3000 mm fixed directly underneath the ceiling on a 50 mm high metal rail wall distance 150 mm test surface width x height = 3500 mm x 2950 mm (starting at the lower edge of the metal rail) Room: E Volume: 199.60 m³ Size: 10.32 m² Date of test: 2017-04-24 Frequency [Hz] α S 1/3 octave α p octave 100 0.01 125 0.01 0.00 160 0.04 200 0.08 250 0.11 0.15 315 0.24 400 0.37 500 0.49 0.45 630 0.56 800 0.62 1000 0.50 0.50 1250 0.38 1600 0.46 2000 0.55 0.50 2500 0.48 3150 0.56 4000 0.55 0.55 5000 0.52 Sound absorption coefficient α S 1.2 1.0 0.8 0.6 0.4 0.2 0.0 Equivalent sound absorption area less than 1.0 m² α S Sound absorption coefficient according to ISO 354 α p Practical sound absorption coefficient according to ISO 11654 θ [ C] r. h. [%] B [kpa] without specimen 19.6 32.9 95.3 with specimen 19.6 33.1 95.3 Sound absorption coefficient 125 250 500 1000 2000 4000 Frequency f / Hz Rating according to ISO 11654: Weighted sound absorption coefficient α w = 0.45 Sound absorption class: D Rating according to ASTM C423: Noise Reduction Coefficient NRC = 0.40 Sound Absorption Average SAA = 0.40 MÜLLER-BBM Planegg, 2017-04-24 No. of test report M111250/16 Appendix A Page 1 Bau4(v1,11,55,0) - R:\BAU\Pruefst\Bau4Data\111\111250\2017-04-24 E\111250_2017-04-24 E_1.mb4: 24.04.2017

Sound absorption coefficient ISO 354 Measurement of sound absorption in reverberation rooms Client: Vescom B.V., Sint Jozefstraat 20, 5753 AV Deurne, Netherland Test specimen: Fabric Corsica Wall distance 150 mm, folded arrangement (100 % fabric addition) Curtain fabric: curtain fabric Corsica area-related mass m" = 107 g/m² airflow resistance R S = 255 Pa s/m thickness t = 0,35 mm Tested arrangement: mounting type following G-150 acc. to EN ISO 354, without enclosing frame two curtains: one curtain with width x height = 3520 mm x 3000 mm and one curtain with width x height = 3500 mm x 3000 mm arrangement with 20 mm overlap fixed directly underneath the ceiling on a 50 mm high metal rail wall distance 150 mm test surface width x height = 3500 mm x 2950 mm (starting at the lower edge of the metal rail) Room: E Volume: 199.60 m³ Size: 10.32 m² Date of test: 2017-04-24 Frequency [Hz] α S 1/3 octave α p octave 100 0.05 125 0.09 0.10 160 0.17 200 0.29 250 0.37 0.40 315 0.54 400 0.63 500 0.68 0.65 630 0.67 800 0.72 1000 0.71 0.70 1250 0.72 1600 0.73 2000 0.75 0.75 2500 0.76 3150 0.78 4000 0.80 0.80 5000 0.80 Sound absorption coefficient α S 1.2 1.0 0.8 0.6 0.4 0.2 0.0 Equivalent sound absorption area less than 1.0 m² α S Sound absorption coefficient according to ISO 354 α p Practical sound absorption coefficient according to ISO 11654 θ [ C] r. h. [%] B [kpa] without specimen 19.6 32.9 95.3 with specimen 19.6 33.8 95.3 Sound absorption coefficient 125 250 500 1000 2000 4000 Frequency f / Hz Rating according to ISO 11654: Weighted sound absorption coefficient α w = 0.65 (H) Sound absorption class: C Rating according to ASTM C423: Noise Reduction Coefficient NRC = 0.65 Sound Absorption Average SAA = 0.63 MÜLLER-BBM Planegg, 2017-04-24 No. of test report M111250/16 Appendix A Page 2 Bau4(v1,11,55,0) - R:\BAU\Pruefst\Bau4Data\111\111250\2017-04-24 E\111250_2017-04-24 E_2.mb4: 24.04.2017

Fabric Corsica, company Vescom B.V. Figure B.1. Flat arrangement, test arrangement in the reverberation room: frontal view. Figure B.2. Flat arrangement, test arrangement in the reverberation room: diagonal view. 2017-04-24 Appendix B, Page 1

Fabric Corsica, company Vescom B.V. Figure B.3. Folded arrangement, test arrangement in the reverberation room: frontal view. Figure B.4. Folded arrangement, test arrangement in the reverberation room: diagonal view. 2017-04-24 Appendix B, Page 2

Description of the test procedure for the determination of the sound absorption in a reverberation room 1 Measurand The sound absorption coefficient of the test object was determined. For this purpose the mean value of the reverberation time in the reverberation room with and without the test object was measured. The sound absorption coefficient was calculated using the following equation: A T S S A T 1 1 55.3V 4V ( m2 m1) c2t2 c1t 1 With: S sound absorption coefficient; A T equivalent sound absorption area of the test object in m 2 ; S area covered by the test object in m 2 ; V volume of the reverberation room in m 3 ; c 1 c 2 propagation speed of sound in air in the reverberation room without test object in m/s; propagation speed of sound in air in the reverberation room with test object in m/s; T 1 reverberation time in the reverberation room without test object in s; T 2 reverberation time in the reverberation room with test object in s; m 1 power attenuation coefficient in the reverberation room without test object in m -1 ; m 2 power attenuation coefficient in the reverberation room with test object in m -1. The different dissipation during the sound propagation in the air was taken into account according to paragraph 8.1.2 of EN ISO 354 [1]. The dissipation was calculated according to ISO 9613-1 [4]. The climatic conditions during the measurements are indicated in the test certificates. Information on the repeatability and reproducibility of the test procedure are given in EN ISO 354 [1]. 2 Test procedure 2.1 Description of the reverberation room The reverberation room complies with the requirements according to EN ISO 354 [1]. The reverberation room has a volume of V = 199.6 m 3 and a surface of S = 216 m 2. 2017-04-24 Appendix C, Page 1

Six omni-directional microphones and four loudspeakers were installed in the reverberation room. In order to improve the diffusivity, six composite sheet metal boards dimensioned 1.2 m x 2.4 m and six composite sheet metal boards dimensioned 1.2 m x 1.2 m were suspended curved and irregularly. Figure C.1 shows the drawings of the reverberation room. Figure C.1. Plan view and sections of the reverberation room. 2017-04-24 Appendix C, Page 2

2.2 Measurement of reverberation time The determination of the impulse responses were carried out according to the indirect method. In all tests, a sinusoidal sweep with pink noise spectrum was used as test signal. In the reverberation room with and without test objects each 24 independent combinations of loudspeakers and microphones were measured. The reverberation time was evaluated according to EN ISO 354 [1], using a linear regression for the calculation of the reverberation time T 20 from the level of a backward integrated impulse response. The determined reverberation times in the reverberation room with and without test object are indicated in Table C.1. Table C.1. Reverberation times without and with test objects. Reverberation time T / s Frequency f / Hz T 1 (without test object T 2 (with test object) Appendix A page 1 Appendix A page 2 100 5.16 5.06 4.78 125 4.94 4.87 4.31 160 5.27 4.95 4.10 200 5.07 4.52 3.45 250 5.20 4.37 3.21 315 5.08 3.66 2.71 400 5.40 3.31 2.59 500 5.45 2.94 2.48 630 5.27 2.70 2.47 800 5.00 2.51 2.33 1000 5.04 2.78 2.35 1250 5.02 3.13 2.33 1600 4.85 2.83 2.28 2000 4.41 2.49 2.15 2500 3.60 2.32 1.93 3150 2.82 1.88 1.66 4000 2.13 1.55 1.39 5000 1.64 1.30 1.17 2017-04-24 Appendix C, Page 3

2.3 List of test equipment The test equipment used is listed in Table C.2. Table C.2. Test equipment. Name Manufacturer Type Serial-No. AD-/DA-converter RME Multiface II 23556871 Amplifier APart Champ 2 09050048 Dodecahedron Müller-BBM DOD360A 372828 Dodecahedron Müller-BBM DOD360A 372829 Dodecahedron Müller-BBM DOD360A 372830 Dodecahedron Müller-BBM DOD360A 372831 Microphone Microtech M370 1355 Microphone Microtech M360 1785 Microphone Microtech M360 1786 Microphone Microtech M360 1787 Microphone Microtech M360 1788 Microphone Microtech M360 1789 Microphone power supply MFA IV80F 330364 Hygro-/Thermometer Testo Saveris H1E 01554624 Barometer Lufft Opus 10 030.0910.0003.9. 4.1.30 Software for measurement and evaluation Müller-BBM Bau 4 Version 1.10 2017-04-24 Appendix C, Page 4