BIAXIAL STRENGTH INVESTIGATION OF CFRP COMPOSITE LAMINATES BY USING CRUCIFORM SPECIMENS

Similar documents
An investigation of the mechanical behaviour of carbon epoxy cross ply cruciform specimens under biaxial loading

NUMERICAL MODELING OF GAS LEAKAGE THROUGH DAMAGED COMPOSITE LAMINATES

Open-hole compressive strength prediction of CFRP composite laminates

PREDICTION OF OUT-OF-PLANE FAILURE MODES IN CFRP

Failure analysis of serial pinned joints in composite materials

Module III - Macro-mechanics of Lamina. Lecture 23. Macro-Mechanics of Lamina

Modelling the nonlinear shear stress-strain response of glass fibrereinforced composites. Part II: Model development and finite element simulations

Tensile behaviour of anti-symmetric CFRP composite

Computational Analysis for Composites

DAMAGE SIMULATION OF CFRP LAMINATES UNDER HIGH VELOCITY PROJECTILE IMPACT

PRELIMINARY PREDICTION OF SPECIMEN PROPERTIES CLT and 1 st order FEM analyses

INTERNATIONAL JOURNAL OF APPLIED ENGINEERING RESEARCH, DINDIGUL Volume 2, No 1, 2011

Failure Analysis of Unidirectional Composite Pinned- Joints

NUMERICAL MODELLING OF COMPOSITE PIN- JOINTS AND EXPERIMENTAL VALIDATION

COMPARISON OF NUMERICAL SIMULATION AND EXPERIMENT OF A FLEXIBLE COMPOSITE CONNECTING ROD

Coupling of plasticity and damage in glass fibre reinforced polymer composites

The Accuracy of Characteristic Length Method on Failure Load Prediction of Composite Pinned Joints

LAMINATION THEORY FOR THE STRENGTH OF FIBER COMPOSITE MATERIALS

THE ROLE OF DELAMINATION IN NOTCHED AND UNNOTCHED TENSILE STRENGTH

Non-conventional Glass fiber NCF composites with thermoset and thermoplastic matrices. F Talence, France Le Cheylard, France

SKIN-STRINGER DEBONDING AND DELAMINATION ANALYSIS IN COMPOSITE STIFFENED SHELLS

EVALUATION OF DAMAGE DEVELOPMENT FOR NCF COMPOSITES WITH A CIRCULAR HOLE BASED ON MULTI-SCALE ANALYSIS

2 Experiment of GFRP bolt

Finite element modelling of infinitely wide Angle-ply FRP. laminates

Dynamic analysis of Composite Micro Air Vehicles

QUESTION BANK Composite Materials

Module 7: Micromechanics Lecture 25: Strength of Materials Approach. Introduction. The Lecture Contains. Effective Transverse Modulus

TABLE OF CONTENTS. Mechanics of Composite Materials, Second Edition Autar K Kaw University of South Florida, Tampa, USA

COMPRESSIVE BEHAVIOR OF IMPACT DAMAGED COMPOSITE LAMINATES

Enhancing Prediction Accuracy In Sift Theory

2-D biaxial testing and failure predictions of IM7/977-2 carbon/epoxy quasi-isotropic laminates q

Prediction of Elastic Constants on 3D Four-directional Braided

Multiscale Approach to Damage Analysis of Laminated Composite Structures

ISSN: ISO 9001:2008 Certified International Journal of Engineering Science and Innovative Technology (IJESIT) Volume 2, Issue 4, July 2013

RATE-DEPENDENT OFF-AXIS COMPRESSIVE STRENGTH OF A UNIDIRECTIONAL CARBON/EPOXY LAMINATE AT HIGH TEMPERATURE

A FINITE ELEMENT MODEL TO PREDICT MULTI- AXIAL STRESS-STRAIN RESPONSE OF CERAMIC MATRIX COMPOSITES WITH STRAIN INDUCED DAMAGE

ME 2570 MECHANICS OF MATERIALS

THREE DIMENSIONAL STRESS ANALYSIS OF THE T BOLT JOINT

NUMERICAL SIMULATION OF DAMAGE IN THERMOPLASTIC COMPOSITE MATERIALS

Crash and Impact Simulation of Composite Structures by Using CAE Process Chain

MECHANICS OF MATERIALS

A RESEARCH ON NONLINEAR STABILITY AND FAILURE OF THIN- WALLED COMPOSITE COLUMNS WITH OPEN CROSS-SECTION

DAMAGE MECHANICS MODEL FOR OFF-AXIS FATIGUE BEHAVIOR OF UNIDIRECTIONAL CARBON FIBER-REINFORCED COMPOSITES AT ROOM AND HIGH TEMPERATURES

EXPERIMENTAL AND THEORETICAL STUDY OF THE DAMAGE ONSET IN BIAXIAL CRUCIFORM SPECIMENS UNDER STATIC AND HYSTERESIS LOADING

Comparison of Ply-wise Stress-Strain results for graphite/epoxy laminated plate subjected to in-plane normal loads using CLT and ANSYS ACP PrepPost

A STRUCTURE DESIGN OF CFRP REAR PRESSURE BULKHEAD WITHOUT STIFFENERS

Influence of fibre proportion and position on the machinability of GFRP composites- An FEA model

Size Effects In the Crushing of Honeycomb Structures

[5] Stress and Strain

The numerical simulation research of an Ultra-Light Photovoltaic Cell multilayer composite structure

FINITE ELEMENT ANALYSIS OF COMPOSITE MATERIALS

THE MUTUAL EFFECTS OF SHEAR AND TRANSVERSE DAMAGE IN POLYMERIC COMPOSITES

Keywords: Adhesively bonded joint, laminates, CFRP, stacking sequence

MECHANICS OF MATERIALS

Impact and Crash Modeling of Composite Structures: A Challenge for Damage Mechanics

FINITE ELEMENT AND EXPERIMENTAL STUDY OF NOVEL CONCEPT OF 3D FIBRE CELL STRUCTURE

Fracture Mechanics, Damage and Fatigue: Composites

PREDICTION OF OPEN HOLE COMPRESSIVE FAILURE FOR QUASI-ISOTROPIC CFRP LAMINATES BY MMF/ATM METHOD

EMA 3702 Mechanics & Materials Science (Mechanics of Materials) Chapter 2 Stress & Strain - Axial Loading

Analysis of nonlinear shear deformations in CFRP and GFRP textile laminates

NUMERICAL FEM ANALYSIS FOR THE PART OF COMPOSITE HELICOPTER ROTOR BLADE

USE OF DIGITAL IMAGE CORRELATION TO OBTAIN MATERIAL MODEL PARAMETERS FOR COMPOSITES

Project MMS13 Task 5 Report No 3 (M6/D3)

COMPARISON OF EXPERIMENTAL RESULTS WITH FEM ONES OF RECTANGULAR CFRP TUBES FOR FRONT SIDE MEMBERS OF AUTOMOBILES

Stress-strain response and fracture behaviour of plain weave ceramic matrix composites under uni-axial tension, compression or shear

Calculation of Damage-dependent Directional Failure Indices from the Tsai-Wu Static Failure Criterion

SIZE EFFECTS IN THE COMPRESSIVE CRUSHING OF HONEYCOMBS

Modeling and Simulations of Aircraft Structures Stiffness, Damage, and Failure Prediction for Laminated Composites

Strength of GRP-laminates with multiple fragment damages

IMPACT STRENGTH AND RESPONSE BEHAVIOR OF CFRP GUARDER BELT FOR SIDE COLLISION OF AUTOMOBILES

NORMAL STRESS. The simplest form of stress is normal stress/direct stress, which is the stress perpendicular to the surface on which it acts.

FASTENER PULL-THROUGH FAILURE IN GFRP LAMINATES

Fig. 1. Circular fiber and interphase between the fiber and the matrix.

EXPERIMENTAL CHARACTERIZATION AND COHESIVE LAWS FOR DELAMINATION OF OFF-AXIS GFRP LAMINATES

University of Sheffield The development of finite elements for 3D structural analysis in fire

Mechanical Behavior of Circular Composite Springs with Extended Flat Contact Surfaces

FLEXURAL RESPONSE OF FIBER RENFORCED PLASTIC DECKS USING HIGHER-ORDER SHEAR DEFORMABLE PLATE THEORY

BioMechanics and BioMaterials Lab (BME 541) Experiment #5 Mechanical Prosperities of Biomaterials Tensile Test

Special edition paper

Multi Disciplinary Delamination Studies In Frp Composites Using 3d Finite Element Analysis Mohan Rentala

KINK BAND FORMATION OF FIBER REINFORCED POLYMER (FRP)

Samantha Ramirez, MSE. Stress. The intensity of the internal force acting on a specific plane (area) passing through a point. F 2

POST-PEAK BEHAVIOR OF FRP-JACKETED REINFORCED CONCRETE COLUMNS

IJSER 1. INTRODUCTION. M.Elhadary

Strength Prediction Of Composite Laminate

International Journal of Innovative Research in Science, Engineering and Technology Vol. 2, Issue 7, July 2013

ME 243. Mechanics of Solids

five Mechanics of Materials 1 ARCHITECTURAL STRUCTURES: FORM, BEHAVIOR, AND DESIGN DR. ANNE NICHOLS SUMMER 2017 lecture

EXPLICIT DYNAMIC SIMULATION OF DROP-WEIGHT LOW VELOCITY IMPACT ON CARBON FIBROUS COMPOSITE PANELS

MODELING OF THE BEHAVIOR OF WOVEN LAMINATED COMPOSITES UNTIL RUPTURE

FE-Analysis of Stringer-to-floor-beam Connections in Riveted Railway Bridges

4.MECHANICAL PROPERTIES OF MATERIALS

In Situ Ultrasonic NDT of Fracture and Fatigue in Composites

Fig. 1. Different locus of failure and crack trajectories observed in mode I testing of adhesively bonded double cantilever beam (DCB) specimens.

Prediction of The Ultimate Strength of Composite Laminates Under In-Plane Loading Using A Probabilistic Approach

MECHANICAL FAILURE OF A COMPOSITE HELICOPTER STRUCTURE UNDER STATIC LOADING

An orthotropic damage model for crash simulation of composites

PREDICTION OF BUCKLING AND POSTBUCKLING BEHAVIOUR OF COMPOSITE SHIP PANELS

Stress intensity factors for an inclined and/or eccentric crack in a finite orthotropic lamina

University of Bristol - Explore Bristol Research. Early version, also known as pre-print

Transcription:

BIAXIAL STRENGTH INVESTIGATION OF CFRP COMPOSITE LAMINATES BY USING CRUCIFORM SPECIMENS H. Kumazawa and T. Takatoya Airframes and Structures Group, Japan Aerospace Exploration Agency 6-13-1, Ohsawa, Mitaka, Tokyo, JAPAN 181-0015 kumazawa.hisashi@jaxa.jp ABSTRACT In this study, biaxial failure strength of quasi-isotropic CFRP (carbon fiber reinforced plastic) composite laminate was investigated experimentally. In-plane biaxial tests with using CFRP cruciform specimens were conducted to measure biaxial failure strains with strain gauges. High speed photographs of biaxial fracture indicated that failure in the cruciform specimen was initiated at gauge area and breakage was developed to GFRP (glass fiber reinforced plastic) tab regions of the specimen. Failure strains under uniaxial stress measured with the cruciform specimens were compared with those measured with strip specimens. Both failure strains were approximately coincident, which proved the validity of the in-plane biaxial strength tests with cruciform specimens. Failure strain in the direction of higher load was approximately constant in the first quadrant of failure envelope. Failure strain under uniaxial tensile stress was higher than those under biaxial tensile stress. Keywords: CFRP laminate, Biaxial load, Cruciform Specimen, Failure Envelope, Biaxial Strength INTRODUCTION New engineering materials are being developed to improve performance for vehicle structures. Especially, light weight and high strength materials are expected in aeronautical, astronautical and transportation industries. Applications of composite materials, as light weight materials, are recently widening for aerospace structures. Multi-axial failure criteria of the composite materials are very important for design of the aerospace structures, but have been not yet sufficiently established due to microscopic anisotropy and complicated fracture mechanisms in the composite materials. Many damage and failure criteria for composite materials under multi-axial stresses have been proposed and evaluated using experimental data [1]. Substantial experimental data is needed to assess the prediction by the proposed criteria. However, multi-axial strength data is not enough for new materials because multi-axial testing methods do not become widely used due to difficulties to conduct tests and particularity of facilities. Many methods to evaluate the multi-axial mechanical characteristics are suggested. One of the effective methods to acquire the biaxial mechanical properties of the plate is an in-plane biaxial testing with a planar cruciform specimen.

In-plane biaxial tests with cruciform specimens had been employed to measure the biaxial mechanical properties of fabrics and yield locus of metal materials for decades. Recently biaxial mechanical properties of composite materials were obtained with using cruciform specimens. Mailly et al.[2] measured biaxial strength of GFRP unidirectional materials with cruciform specimens. They reported substantial influence of longitudinal stress on transverse nonlinearity of GFRP materials. Smits et al.[3] investigated effect of cruciform specimen geometries on biaxial failure strain of GFRP laminates, and determined a suitable geometry for biaxial testing of fiber reinforced composites. Welsh et al.[4] experimentally acquired two-dimensional failure envelope for quasi-isotropic CFRP laminates with using cruciform specimens, and estimated failure stress with φ 40.1 90 10 R80 80 400 160 φ160 φ40 1 8 24 [unit:mm] Fig.1. CFRP cruciform specimen. Fig.2. Biaxial Testing Machine. Fig. 3. Finite element mesh of quarter model of cruciform specimen. Table 1. Elastic constants of HTA/#101 CF/epoxy quasi-isotropic laminate. Property E(GPa) 49.4 G(GPa) 18.9 ν 0.31 Table 2. Elastic constants of GFRP laminate. Property E(GPa) 30.0 G(GPa) 11.5 ν 0.3

bypass correction factor. In Japan Aerospace Exploration Agency(former National Aerospace Laboratory of Japan), Susuki[5] conducted biaxial fatigue tests with cruciform specimens for fiber reinforced composites in addition to static fracture tests, and the results indicated that biaxial loading phase has significant impact on fatigue strength of the composite laminates. Khamsesh et al.[6] carried out open-hole biaxial compression tests for CFRP composite laminates, and identified failure mechanisms of composite laminate with open-hole under biaxial compressive load. In this study, biaxial strength of quasi-isotropic CFRP composite laminates was experimentally acquired. In-plane biaxial tests with using CFRP cruciform specimens were conducted to measure biaxial failure strains with strain gauges. Strain and stress distributions in gauge area of the cruciform specimen were evaluated by finite element analysis and compared to validate measured strain level and ratio. Failure strains under uniaxial stress measured with the cruciform specimens were compared with those measured with strip specimens to prove the validity of the in-plane biaxial strength tests. Influence of biaxial loadings on failure strains of quasi-isotropic CFRP laminates were evaluated by the experimental results. EXPERIMENTAL PROCEDURE Cruciform Specimen Material used in this study was carbon fiber/180 C cured epoxy HTA/#101. Stacking sequence of specimens was (0/90/45/-45)s. Thickness of the laminates was about 1.0mm. GFRP tabs are bonded on both sides of the CFRP laminate. Geometry of the biaxial cruciform specimens is shown in Fig. 1. The cruciform specimen geometry was determined based on specimens that Susuki proposed in [5]. The cruciform specimen was designed to apply the biaxial load with pin connections between four arms of the cruciform specimen and cross heads of a biaxial testing machine. However, applying load to the specimen with the pin connections was insufficient to achieve the final failure. Then hydraulic wedge grips were employed to connect the arms of the cruciform specimen to the cross heads of the biaxial testing machine in this study. In-Plane Biaxial Testing Machine The biaxial testing machine used in this study consists of four hydraulic actuators of 245kN (tension/compression) capacity for static load. These four actuator-assemblies are diagonally mounted in an octagonal box-shaped frame (Fig. 2). Each loading axis is depicted as x- and y-axis. The testing machine can apply biaxial load with arbitrary load ratio to a cruciform specimen. One advantageous aspect of in-plane biaxial tests with cruciform specimens is that biaxial strain or stress ratio can be set arbitrarily. A particular problem with the operation of cruciform type biaxial test has been controlling to minimize the drift of the specimen center with load control. A small rigid movement during the biaxial test can give undesirable side force and unexpected damage to the cruciform specimen. It seems to be difficult to control four actuators not to generate imbalance at all by load feedback signals only. A double loop feedback control system was developed to carry out static tests and fatigue tests without readjustments of the specimen position.

Because of the round shaped reinforcement of GFRP tabs around the gauge area, stresses in the center portion of the specimen are not simply predictable. Before biaxial strength tests, the strains induced by the biaxial loads in the gauge area are needed to be obtained as functions of biaxial load. The relationships between biaxial loads and strains are used to determine biaxial load ratio to achieve prescribed biaxial strain (or stress) ratio. FINITE ELEMENT ANALYSIS Strain and stress distributions in the gauge area of the cruciform specimen were evaluated with using ABAQUS 6.7-1, a commercial software package for finite element analysis developed by SIMULIA. The elastic constants of carbon fiber/180 C cured epoxy HTA/#101 quasi-isotropic laminate and GFRP laminate used in the numerical analysis are shown in Tables 1 and 2, respectively. The symbols E, G, ν in these tables refer to extensional modulus, shear modulus and Poisson s ratio, respectively. The calculations for the cruciform specimen under biaxial loadings were conducted under the assumptions of linear-elastic and non-damage development with 1/4 model as shown in Fig. 3. The finite element model consists of 8-node brick elements. It is assumed for simplicity that there are no holes in the arms of the cruciform specimen and biaxial load was applied to arm ends of the cruciform specimen directly. In this study, x and y axes coincide with the 0º and 90º directions of laminates respectively, and the z axis is the direction through the ply thickness. RESULTS AND DISCUSSIONS Calculated Strain and Stress Distributions Numerically calculated stress and strain distributions in the CFRP cruciform specimen under uniaxial loading F x =100kN, F y =0kN (F x : F y =1:0) are shown in Fig. 4, where F x and F y mean x- and y-directional applied forces, respectively. X-directional stress and strain in the gauge area are higher than other regions as shown in Fig. 4(a) and (b), respectively. Y-directional stress in the gauge area in Fig. 4(c) was compressive when the specimen is subjected to x-directional uniaxial tensile load. Ratio of y-directional contraction in Fig. 4(d) to x-directional extension in Fig. 4(b) is higher than Poisson's ratio due to the transverse compression. It is noted that stress field is not uniaxial stress state in the gauge area of the cruciform specimen, even though the cruciform specimen is subjected to uniaxial load. Calculated stress and stress distributions in the CFRP laminate under biaxial loading F x = F y =100kN (F x : F y =1:1) are shown in Fig. 5. Stress and strain distributions in case of F x = F y are symmetrical about the line x=y because the cruciform specimen geometry, the stacking sequence and the applied biaxial load are symmetric. Biaxial stress and strain ratios in the gauge area are also 1:1 when the specimen is subjected to biaxial load with load ratio F x : F y =1:1. Maximum normal stress and strain in the gauge area in Fig.5(F x : F y =1:1) are less than those in Fig. 4(F x : F y =1:0) due to Poisson s ratio and round shaped reinforcement of GFRP tabs. Numerical and experimental results of biaxial strains under uniaxial and biaxial loading (F x : F y =1:0 and 1:1) in the strain range within 0.3% are compared in Fig. 6. These

figures show that numerical results are in good agreement with experimental results, and biaxial strain ratio changes in relation to the biaxial loading ratio. Relationships among Biaxial Load, Strain and Stress Relationships among x-directional uniaxial load F x, strains (ε x and ε y ) and stresses (σ x and σ y ) in the strain range within 0.3% are shown in Fig. 7, where ε i and σ i (i=x, y) are i-directional normal strain and stress, respectively. Strains (ε x and ε y ) were measured by using strain gauges. Stress in the gauge area can be calculated from cross sectional area in the gauge area and force that carried through the gauge area conceptually. Applied force to the cruciform specimen is carried through not only the gauge area but also other regions of the specimen. However, fraction of the force carried through gauge area is depend on specimen geometry and material constants, and unable to be determined simply. Then, stresses (σ x and σ y ) had to be calculated from elastic constants and the biaxial strains. In Fig. 7, y-directional stress σ y is negative value, which means that gauge area is transversely compressed even though the specimen is subjected to uniaxial load. Biaxial strains under certain biaxial load ratios can be calculated based on the relationship between biaxial strains and uniaxial load with superposition principle in the y mal Stress x (a) x-directional stress 500000000. 468750000. 437500000. 406250000. 375000000. 343750000. 312500000. 281250000. 250000000. 218750000. 187500000. 156250000. 125000000. 93750000. 62500000. 31250000. 0. (Pa) mal Strain (b) x-directional strain 0.011 0.0103 0.00962 0.00894 0.00825 0.00756 0.00687 0.00619 0.0055 0.00481 0.00413 0.00344 0.00275 0.00206 0.00137 0.000688 0. (m/m) 80000000. 0.001 65625000. 0.000563 51250000. 0.000125 36875000. -0.000313 22500000. -0.00075 8125000. -0.00119-6250000. -0.00163-20625000. -0.00206-35000000. -0.0025-49375000. -0.00294-63750000. -0.00338-78125000. -0.00381-92500000. -0.00425-1.069E+8-0.00469-1.213E+8-0.00513 y mal Stress x (c) y-directional stress -1.356E+8-1.5E+8 (Pa) -0.00556-0.006 (m/m) Fig. 4. Calculated normal stress and strain in cruciform specimens under uniaxial loading (F x =100kN, F y =0kN). mal Strain (d) y-directional strain

350000000. 328125000. 306250000. 284375000. 262500000. 240625000. 218750000. 196875000. 175000000. 153125000. 131250000. 109375000. 87500000. 65625000. 43750000. 0.006 0.0055 0.005 0.0045 0.004 0.0035 0.003 0.0025 0.002 0.0015 0.001 0.0005 0. -0.0005-0.001 y mal Stress x (a) x-directional stress 21875000. 0. (Pa) -0.0015-0.002 (m/m) Fig. 5. Calculated x-directional normal stress and strain in cruciform specimens under uniaxial loading (F x =100kN, F y =100kN). range of linear elastic. As an example, several relationships among strain ratio, load ratio and stress ratio are shown in Table 3. In the table, stress is calculated by using strain and elastic constants in Table 1. These ratios are not necessarily coincident with each other with the exception of ratio 1:1 and 1:-1. It is noted in the in-plane biaxial tests with the cruciform specimens that load ratio has to be determined based on the relationships between load ratio and strain ratio in the gauge area. mal Strain (b) x-directional strain Failure under Biaxial Loading Relationships between load and strain under biaxial load F x : F y =0.21:1 and 1:1 in the biaxial fracture tests are shown in Fig. 8. In Fig. 8(a), the cruciform specimen was subjected to biaxial load with load ratio F x : F y =0.21:1, and x- and y-directional strains increased as if stress state is uniaxial, which means ratio of x-directional contraction to y-directional extension is equal to Poisson s ratio. In Fig. 8(b), x- and y- directional strains increase accordance with applied load approximately equally due to the load ratio F x : F y =1:1. Inclination of the strain curves after the half of the fracture load are slightly changing in accordance with applied load, though strains at an early stage of the biaxial loading are almost proportional to the applied load. It is supposed that damages such as matrix cracks occurred at the later stage of the fracture tests and the degradation of stiffness due to the damages were the cause of the inclination change at the later stage of the fracture. Photographs of fracture near the gauge area of the cruciform specimen under biaxial loading F x : F y =1:1 were taken by a high speed camera (model:exilim EX-F1, Casio Computer Co., Ltd., Japan) as shown in Fig. 9. The photographs were taken with frame rate 300 frame/second and resolution 512 384pixels. Figure 9 indicates that fracture was initiated at the gauge area, and subsequently breakage in GFRP tabs was developed in the directions of x- and y- axes. Photographs of the cruciform specimens after the biaxial fracture tests with load ratio F x : F y =0.21:1 and 1:1 are shown in Fig. 10. Breakage in the cruciform specimen with load control typically reaches the free edge of the cruciform specimens, especially

corner fillets. Figure 10 reveals that the breakage stops away from the free edges of the cruciform specimens, though the biaxial load was applied to the specimen with load control. In the experiments, the control system of the biaxial testing machine detects drastic load reduction, which means the stiffness reduction due to the fracture at the gauge area, and immediately activated an emergency stop with displacement control before the breakage reaches the free edges of the specimen. Fractures under y-directional uniaxial stress at the gauge area was developed to x- direction only as shown in Fig.10(a). Fractures under biaxial stress (σx=σy) was developed to both x- and y-directions from the gauge area as shown in Fig. 10(b). Effect of Biaxial Loadings on Biaxial Strength Biaxial failure strain measured with using the cruciform specimens is shown in Fig. 11. In this figure, failure strain measured with using strip specimens under uniaxial loading is also plotted. The strip specimen size was 150mm length, 15mm width and 1mm thickness. Stacking sequence of the strip laminate was (45/0/-45/90)s. Fracture strains obtained with the strip specimens were approximately equal to those obtained with the cruciform specimens in the uniaxial stress condition. The approximated correspondence of fracture strains under uniaxial stress in both strip and cruciform specimens indicates validity of in-plane biaxial strength testing with cruciform specimens. Biaxial failure strains with strain ratios ε x : ε y =1:1, 0.3:1, -0.3:1, and -0.7:1 are plotted in Fig. 11. In the first quadrant of Fig. 11 (ε x : ε y =1:1, 0.3:1), y-directional failure strains are approximately constant irrespective of x-directional failure strain. In the second quadrant of Fig. 11(ε x : ε y =-0.3:1, -0.7:1), y-directional failure strains are also approximately constant irrespective of x-directional failure strain. Comparing the first and second quadrants, y-directional failure strains in the second quadrant are larger than those in the first quadrant. However, more data for biaxial strength is required to widen the range of failure envelope to all quadrants and to decrease sampling error due to the small samples. CONCLUSIONS The biaxial strength of quasi-isotropic CFRP laminates was experimentally acquired with using the cruciform specimens. Strain and stress distributions in gauge area of the cruciform specimen were evaluated by finite element analysis and compared to validate measured strain level and ratio. Biaxial load ratio to obtain the final biaxial failure strains with prescribed strain ratio was calculated based on the relationships between biaxial load and strain under uniaxial loadings. High speed photographs of biaxial fracture indicated that failure was initiated at gauge area and breakage was developed to GFRP tab regions in the specimen. In the first quadrant of failure strain envelope, y- directional failure stains were approximately constant irrespective of x-directional failure strain. However, fracture strains in the second quadrant of the failure envelope were larger than those in the first quadrant. Failure strains under uniaxial stress measured with the cruciform specimens were compared with those measured with the strip specimens. Approximated accordance of fracture strains under uniaxial stress

irrespective of specimen type indicated validity of in-plane biaxial strength tests with cruciform specimens. References 1. Hinton M.J., Kaddour A.S. and Soden P.D., Failure Criteria in Fibre Reinforced Polymer Composites: The World-Wide Failure Exercise, Elsevier Science Ltd, Oxford, UK, 2004. 2. Mailly L. and Wang S.S., Recent Development of Planar Cruciform Experiment on Biaxial Tensile Deformation and Failure of Unidirectional Glass/Epoxy Composite, Journal of Composite Materials, Vol. 42, No. 13, pp. 1359-1379, 2008. 3. Smits A., Van Hemelrijcka D., Philippidisb T.P. and Cardona A., Design of a Cruciform Specimen for Biaxial Testing of Fibre Reinforced Composite Laminates, Composites Science and Technology, Vol. 66, No. 7-8, pp. 964-975, 2006. 4. Welsh J.S., Mayes J.S. and Biskne A.C., 2-D Biaxial Testing and Failure Predictions of IM7/977-2 Carbon/Epoxy Quasi-Isotropic Laminates, Composite Structures, Vol. 75, No. 1-4, pp. 60-66, 2006. 5. Susuki I., Strength Properties of Composite Laminate under Biaxial Loadings, Proceedings of the Tenth International Conference on Composite Materials (ICCM-10) - Volume IV: Characterization and Ceramic Matrix Composites, pp. 73-80, 1995. 6. Khamseh A.R. and Waas A. M., Failure Mechanisms of Composite Plates with a Circular Hole under Remote Biaxial Planar Compressive Loads, Journal of engineering materials and technology, Vol. 119, No. 1, pp. 56-64, 1997. Strain (%) 0.3 0.2 0.1 0 HTA/#101 (0/90/45/-45)s #02 Fx : Fy = 1 : 0 ε x (experiment) ε y (experiment) ε x (FEM) ε y (FEM) Strain (%) 0.3 0.2 0.1 HTA/#101 (0/90/45/-45)s #06 Fx : Fy = 1 : 1 ε x (experiment) ε y (experiment) ε x (FEM) ε y (FEM) -0.1 0 10 20 0 10 20 30 40 50 Load Fx(kN) Load Fy (kn) (a) F x : F y = 1 : 0 (b) F x : F y = 1 : 1 Fig. 6. Comparison between measured and calculated strains under biaxial load (F x : F y =1:0 and 1:1).

Strain (%) 0.3 0.2 0.1 0-0.1 HTA/#101 (0/90/45/-45)s #02 Fx : Fy = 1 : 0 ε x ε y σ x σ y 300 200 100 0-100 Stress (MPa) 0 10 20 Load Fx(kN) Fig. 7. Biaxial strain and stress under uniaxial load (F x : F y =1:0). Table 3. Ratio of biaxial strain, load and stress. strain ratio load ratio stress ratio εx:εy F x:f y σx:σy 1:1 1:1 1:1 0.3:1 0.68:1 0.56:1-0.3:1 0.21:1 0.01:1-0.7:1-0.34:1-0.5:1-1:1-1:1-1:1 1.5 1 HTA/#101 (0/90/45/-45)s #15 Fx : Fy = 0.21 : 1 : ε X : ε Y 1 0.8 HTA/#101 (0/90/45/-45)s #17 Fx : Fy = 1 : 1 : ε X : ε Y Strain (%) 0.5 Strain (%) 0.6 0.4 0 0.2-0.5 0 50 100 0 50 100 Load Fy (kn) Load Fy (kn) (a) F x : F y = 0.21 : 1 (b) F x : F y = 1 : 1 Fig. 8. Load-strain curves under biaxial loading ratio F x : F y =1:1 and 0.21:1.

Fig.9. High Speed photograph of fracture in gauge area of cruciform specimen under biaxial loading (F x : F y =1:1). y x (a) F x : F y = 0.21 : 1 (b) F x : F y = 1 : 1 Fig.10. Fracture of cruciform specimens under biaxial loading (F x : F y = 0.21:1 and 1:1) 2 HTA/#101quasi-isotropic : cruciform specimen : strip specimen ε Y (%) 1-1 0 0 1 ε X (%) Fig. 11. Biaxial failure strain of CF/Epoxy quasi-isotropic laminates.