THE TRIPLE QUAD THAT KNOWS THE VALUE OF TIME. QSight Triple Quadrupole LC/MS/MS Platform. For research use only. Not for use in diagnostic procedures.

Similar documents
ABI 3200 Q TRAP LC/MS/MS System

Quadrupole Time-of-Flight Liquid Chromatograph Mass Spectrometer LCMS-9030 C146-E365

Thermo Scientific ICP-MS solutions for the semiconductor industry. Maximize wafer yields with ultralow elemental detection in chemicals and materials

Translational Biomarker Core

Guide to Peptide Quantitation. Agilent clinical research

IN QUALITATIVE ANALYSIS,

High-throughput Quantification of DNA for NGS Library Prep with the Zephyr G3 Workstation and the VICTOR Nivo Plate Reader

IRMS. perspective. Isotope Ratio Mass Spectrometry.

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW

Bruker Daltonics. EASY-nLC. Tailored HPLC for nano-lc-ms Proteomics. Nano-HPLC. think forward

ICP-MS. High Resolution ICP-MS.

Everyday NMR. Innovation with Integrity. Why infer when you can be sure? NMR

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION

TOXICOLOGY & FORENSIC APPLICATIONS

WALKUP LC/MS FOR PHARMACEUTICAL R&D

Overview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada)

Whole Tablet Measurements Using the Frontier Tablet Autosampler System

Defining quality standards for the analysis of solid samples

FORENSIC TOXICOLOGY SCREENING APPLICATION SOLUTION

Theory and Practical Consequences.

Analysis of Pharmaceuticals and Personal Care Products in River Water Samples by UHPLC-TOF

Introducing the Agilent 7000A QQQ-MS for GC Sunil Kulkarni Product Specialist Agilent Technologies

Analysis of Polar Metabolites using Mass Spectrometry

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

PERSPECTIVE STABLE ISOTOPE RATIO MS

SIFT-MS SELECTED ION FLOW TUBE MASS SPECTROMETRY TECHNOLOGY OVERVIEW \ SYFT TECHNOLOGIES

HYPHENATED TECHNOLOGY GUIDE

HYPHENATED TECHNOLOGY GUIDE

Finnigan LCQ Advantage MAX

Chemical Labeling Strategy for Generation of Internal Standards for Targeted Quantitative Proteomics

RamanStation 400: a Versatile Platform for SERS Analysis

AB SCIEX SelexION Technology Used to Improve Mass Spectral Library Searching Scores by Removal of Isobaric Interferences

ImprovIng ADmE ScrEEnIng productivity In Drug DIScovEry

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

DI 3500 Discrete Aoalvzer

Proven robustness for large-scale metabolomics studies using the Phenomics Workhorse

SIFT-MS. technology overview

Discover what you re missing

Measurement & Analytics Measurement made easy. MB3600-CH70 FT-NIR polyol analyzer Pre-calibrated for OH value determination

Improved Automated Sample Preparation for the Analysis of 25-OH-Vitamin D3 by LC/MS/MS

Thermo Scientific LTQ Orbitrap Velos Hybrid FT Mass Spectrometer

Thermo Finnigan LTQ. Specifications

4000 Q TRAP LC/MS/MS System. Advanced Linear Ion Trap technology at the highest level of sensitivity 4000 QTRAP. LC/MS/MS System

cobas 6000 analyzer series Flexibility you can build on

Key Words Q Exactive, Accela, MetQuest, Mass Frontier, Drug Discovery

ANY MATRIX ANY PARTICLE SIZE ANY INTERFERENCE. NexION 2000 ICP Mass Spectrometer

Meeting the Challenges of Soil Analysis with the Avio 200 ICP-OES

[application note] ACQUITY UPLC/SQD ANALYSIS OF POLYMER ADDITIVES. Peter J. Lee, and Alice J. Di Gioia, Waters Corporation, Milford, MA, U.S.A.

PERSPECTIVE STABLE ISOTOPE RATIO MS

protein biology cell imaging Automated imaging and high-content analysis

Perseverance. Experimentation. Knowledge.

Instrumental Limitations for High Absorbance Measurements in Noise

Analytical Instrumentation

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment

Compounding insights Thermo Scientific Compound Discoverer Software

Analyst Software. Automatic Optimization Tutorial

All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems

Determination of VOC in Artificial Runway by Multiple Headspace Extraction-GC/MS. Gas Chromatography/ Mass Spectrometry APPLICATION.

The Characterization of Nanoparticle Element Oxide Slurries Used in Chemical-Mechanical Planarization by Single Particle ICP-MS

OVERVIEW INTRODUCTION. Michael O Leary, Jennifer Gough, Tanya Tollifson Waters Corporation, Milford, MA USA

Overview. Introduction. André Schreiber 1 and Yun Yun Zou 1 1 AB SCIEX, Concord, Ontario, Canada

Quantitation of High Resolution MS Data Using UNIFI: Acquiring and Processing Full Scan or Tof-MRM (Targeted HRMS) Datasets for Quantitative Assays

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment LCQ Deca XP Plus

Verification of Pharmaceutical Raw Materials Using the Spectrum Two N FT-NIR Spectrometer

SIMATIC Ident Industrial Identification Systems

Whole Tablet Measurements Using the Spectrum One NTS Tablet Autosampler System

Peptide Isolation Using the Prep 150 LC System

ASSESSMENT. Industry Solutions Harness the Power of GIS for Property Assessment

for XPS surface analysis

Revolutionary Sensitivity, Speed, and Performance

10 REASONS THAT THE ZETASIZER NANO IS CHOSEN FOR SCIENTIFIC SUCCESS

Chemical Analysis. PIONA+ Analyzer. Characterization of Engine Fuels by Hydrocarbon Group Type. Gas Chromatography. think forward

GAS CHROMATOGRAPHY MASS SPECTROMETRY. Pre-Lab Questions

A Strategy for an Unknown Screening Approach on Environmental Samples Using HRAM Mass Spectrometry

Benefits of Equipping your Lab with a Time-of-Flight Mass Spectrometer

Confirmation of In Vitro Nefazodone Metabolites using the Superior Fragmentation of the QTRAP 5500 LC/MS/MS System

Types of Analyzers: Quadrupole: mass filter -part1

Agilent ESI and APCI sources: for polar to non-polar compounds

The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity

A Rapid Approach to the Confirmation of Drug Metabolites in Preclinical and Clinical Bioanalysis Studies

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma

Extraction of Methylmalonic Acid from Serum Using ISOLUTE. SAX Prior to LC-MS/MS Analysis

Reaxys Medicinal Chemistry Fact Sheet

New Dynamic MRM Mode Improves Data Quality and Triple Quad Quantification in Complex Analyses

Agilent All Ions MS/MS

Agilent 6400 Series Triple Quadrupole Users Workshop. MH QQQ Users workshop 2/21/2014 1

Analysis of Polyphenols in Saffron Petal Extracts with UHPLC/UV/MS

Lirui Qiao, 1 Rob Lewis, 2 Alex Hooper, 2 James Morphet, 2 Xiaojie Tan, 1 Kate Yu 3

Training Courses. Chromatography training from the Crawford Scientific experts

Design Considerations for a Variable Angle Absolute Reflectance Accessory For the LAMBDA 950/850/650 UV/Vis/NIR and UV/Vis Spectrophotometers

Thermo Scientific ConFlo IV Universal Interface. Continuous Flow Interface. Isotope Ratio MS

Online Reaction Monitoring of In-Process Manufacturing Samples by UPLC

Sample Preparation. Approaches to Automation for SPE

Multi-residue analysis of pesticides by GC-HRMS

Performing Peptide Bioanalysis Using High Resolution Mass Spectrometry with Target Enhancement MRM Acquisition

Information Dependent Acquisition (IDA) 1

cobas 8000 modular analyzer series Intelligent LabPower

Agilent 6400 Series Triple Quadrupole LC/MS/MS Users Session

High-Throughput Protein Quantitation Using Multiple Reaction Monitoring

Transcription:

THE TRIPLE QUAD THAT KNOWS THE VALUE OF TIME QSight Triple Quadrupole LC/MS/MS Platform For research use only. Not for use in diagnostic procedures.

THE IDEAL SYSTEM FOR WHATEVER ANALYSIS YOU PERFORM 2

BETTER LC/MS/MS DETECTION, WHATEVER YOUR APPLICATION WHAT COULD YOU DO WITH AN EXTRA 35 DAYS OF SAMPLE TESTING? METABOLOMICS This quickly evolving field specializes in measuring unique chemical fingerprints generated during cellular function and is a crucial component of systems biology research. The varied chemical nature of these biomarkers makes the robust QSight 220 system a perfect instrument for measuring metabolic signatures from complex biological sample types. PROTEOGENOMICS Proteogenomics is a newly emerging field that harnesses the combined insight of genetic information and transcriptional proteomic analysis. The QSight system's workflow uses that genetic information to predict and validate variant insights by mass spectral analysis of unique peptides associated with target proteins and biomarkers of interest. PERSONALIZED MEDICINE The convergence of pharmacokinetics and metabolomics has driven the need for dynamic results as the field of precision medicine aims to provide optimal personalized care based on accurate and sensitive biological measurements. The QSight system s triple quad technology harnesses the power of mass spec to provide industry-leading accuracy, reliability, and reproducibility for biomarker discovery and analysis, regardless of sample type. You know firsthand how quickly things are changing in the life science field and your lab needs to change to keep pace. There s increased market pressure to analyze more and more complex samples with fewer resources and skilled personnel. Sounds like a scenario in which 15% more uptime might come in handy. That s what the QSight triple quadrupole LC/MS/MS system is designed to give you. More productivity, more samples For example, the system s self-cleaning source means you don t have to power down the system for scheduled cleaning and maintenance. This means up to 35 days more sample testing per year than competitors systems. The dual-source design also reduces complexity for multiplexing, with shorter run times and fewer wash cycles and that s a productivity boost as well. And the flow-based pressure differential pulls ions for better sensitivity and increased reliability and with fewer sample preparation requirements, you get less variability from sample to sample. What s more, the system is easy for everyone in your lab including novice technicians to learn and use, with software that streamlines everything from method development to results processing and reporting. And it requires absolutely no instrument-toinstrument method optimization. The QSight LC/MS/MS system: Finally, a triple quad that gives you more of what you need most: time. www.perkinelmer.com/qsight 3

INNOVATIONS COME TOGETHER TO SET THIS INSIDE AND OUT, IT S SYSTEM APART LC/MS/MS DONE RIGHT An exceptional solution for a wide range of academic and research applications, including metabolomics, proteogenomics, pharmocology, and biomarker discovery, the QSight LC/MS/MS platform delivers the key technologies you count on in a triple quadrupole solution in a compact, easy-to-use design. High sensitivity, even higher productivity Unique StayClean technology employs hot-surface induced desolvation (HSID ), a multi-orthogonal sampling interface that can significantly increase your uptime. A continuous flow of hot gas forms a barrier that prevents most of the ions or clusters from hitting the side walls. It also acts as a constant cleaning agent that flushes away any potential deposits. Plus, solvated charged species are entrained and desolvated in the hot flow of gas, reducing chemical noise and delivering a higher signal-to-noise ratio. Go with the flow Ions are transferred from the HSID interface to the system s Laminar Flow Ion Guide, then moved to the analyzing region by a flow of background gas no axial electrical fields are necessary. This means the system is not susceptible to field fluctuations and delivers consistently high levels of performance. Instrument drift and frequent reoptimization and cleaning are eliminated, for better productivity. Two sources are better than one The system's dual-source technology has two separate ion inlets that operate independently and can be set in ESI or APCI modes, enabling combinations such as ESI/ESI, ESI/APCI, and APCI/APCI with the same or opposite polarities. Unlike single-source instruments, our dual-source technology enables you to collect data in two complementary modes, maximizing the output from a single injection. Plus, it enables you to employ one probe for tuning and another probe for high flow analysis, giving you the capabilities of two MS systems in one. See how easy it is to switch With its high-energy dynode to attract positive ions, the QSight system s UniField Detector causes positive ions to collide with the dynode to form electrons (which cascade into the detector) while negative ions are detected as usual for pulse counting. What you get is near-simultaneous detection of positive and negative ions without the need for high-voltage switching. Polarity switching happens in microseconds, limited only by the ion source and ion path polarity switching not by the detector. 4

Inside and Out, It s LC/MS/MS Done Right Dual Source Two independent probes provide true multiplexing flexibility HSID Interface Provides low background and reliable results day after day, with equal response at any flow rate StayClean Source Selfcleaning design delivers maximum sensitivity and exceptional uptime Laminar Flow Ion Guide Highly efficient field-free transmission Mass Filters High-quality precision rods provide highly stable, precise mass filtering Collision Cell Fast, efficient fragmentation (fast MRMs) shortens cycle time with zero crosstalk UniField Detector Patented technology counts positive and negative ions without highvoltage switching Modular Plug-and-play design for ease of service US CA MASS SPECTROMETER INTERFACE PERKINELMER PATENTS 7,091,477 7,405,398 8,546,750 8,946,622 2,470,452* MASS SPECTROMETER ION GUIDE PROVIDING AXIAL FIELD, AND METHOD 7,868,289 METHOD AND APPARATUS FOR DETECTING POSITIVELY CHARGED AND NEGATIVELY CHARGED IONIZED PARTICLES 7,728,292 MULTI-PRESSURE STAGE MASS SPECTROMETER AND METHODS 9,343,280 UK Small Footprint, Vertical Design Compact 50 cm x 50 cm x 110 cm no benchtop needed 2466156 2489623 *Pending application www.perkinelmer.com/qsight 5

WE'RE DELIVERING SOFTWARE AND SYSTEMS THAT ARE SIMPLICITY ITSELF With Simplicity 3Q software, it s all about making the QSight instrument simple and easy to use. This modular software suite is designed for intuitive, straightforward operation, with wizards guiding you through the workflow, from method development to results processing and reporting. Simplicity 3Q Acquire Module Simplicity 3Q View Module A great solution for data acquisition, Simplicity 3Q Acquire streamlines acquisition method development and batch acquisition, with the highest levels of automation. It s capable of real-time acquisition of more than one thousand MRMs and provides a real-time simultaneous display of large numbers of transitions. And for batch acquisition, it delivers a simple sample editor with an integrated concentration table, and easy table controls. Simplicity 3Q View delivers flexible multi-analyte viewing, overlay plotting, and signal-to-noise analysis. Plus, it provides total ion currents (TICs) and extracting ion currents (XICs) for data exploration and evaluation. Simplicity 3Q Quant Module For data analysis and reporting, Simplicity 3Q Quant software uses autopopulation from data acquisition files for an exceptionally fast, smooth, streamlined workflow for high-throughput situations. And with a full-on view of all navigation data, the software s RapidView Heads-up Display lets you concentrate on your data and your results. Simultaneous review of several analyte MRMs. 6 Simplicity 3Q Service Module The Simplicity 3Q Service module uses AdvIO Electronics to review all settings and feedback, quickly diagnosing or ruling out hardware concerns. And because diagnostics are extremely accurate, downtime is vastly diminished, while repairs are done efficiently and effectively without return calls. Intuitive, real-time read-back facilitates instrument troubleshooting.

LC technology that delivers a whole new level of confidence For the QSight triple quad LC/MS/MS instrument, we ve paired the industry s most robust, flexible, mass spectrometer with the equally capable QSight LX50 UHPLC system, delivering all the sensitivity, specificity, and carryover-elimination capabilities you need for demanding applications. The system delivers three key technologies that help optimize your workflow and enable even higher levels of productivity: Precision Sampling Module With the most advanced fluidics technology in the business, the system s Precision Sampling Module protects your samples from degradation and precipitation, with a precise temperature that ensures stability, and uniform cooling as well. And with its injection-to-injection reproducibility and zero carryover or contamination, you get outstanding analytical performance and column life. Solvent Delivery Module The self-cleaning Solvent Delivery Module uses a rugged linear drive to deliver ultraprecise UHPLC gradient flows of more than 18,000 psi. Each pump head is individually motor-driven and controlled, generating maximum flow control and pulse reductions. And the system is self-priming and can purge itself in minutes freeing your scientists to handle other important tasks. Column Stability Module The system s Column Stability Module maintains a precise, consistent temperature for the column and mobile phases for reproducible retention times, along with enhanced selectivity, improved peak shape, and shorter analysis times. And elevated temperatures reduce column back pressure, allowing for higher solvent flow rates regardless of column and particle size. The Newest Member of an Elite Team We offer a comprehensive portfolio of technologies that fits your workflow perfectly everything from sample preparation to extraction, detection, and characterization. JANUS G3 WORKSTATION The JANUS G3 Workstation delivers application versatility along with flexible throughput, capacity, and dynamic volume range perfect for genomics, biotherapeutics, high-throughput screening, and high-content analysis. And an array of liquid handling deck designs and preprogrammed methods provide seamless integration into any workflow. www.perkinelmer.com/qsight CHEMAGIC 360 PLATFORM Based on our patented magnetic bead technology, the chemagic 360 instrument is the ideal solution for nucleic acid isolation in human genetics, biobanking, HLA typing, and virus/bacteria detection all in a compact benchtop design. Plus, it s configurable with three kinds of chemagic rod heads and can handle sample volumes from 10 µ to 10 ml. DROPLETQUANT The DropletQuant spectrophotometer provides full-spectral microvolume quantitation scans of 96 samples in fewer than five minutes. With sample-throughput flexibility and input volumes of 2 μl, the DropletQuant instrument enables faster time to results. And its wide linear dynamic range for DNA and protein, internal optical calibration, and unique sample plate design prevent cross-contamination and sample evaporation. 7

EVERYTHING YOU NEED UNDER ONE ROOF The right accessories, consumables, and methods We have the consumables and accessories for applications in chromatography and mass spectrometry, and our comprehensive portfolio of solutions is designed to ensure you receive accurate, repeatable results throughout the lifetime of your instrument. Driving your science and your business With our OneSource organization, you re benefiting from multivendor service and support from the absolute best in the business. That means thousands of certified technicians in the field who are familiar with all the techniques you employ. A broad portfolio of services, plus a deep-seated knowledge of the business requirements of our customers, uniquely qualifies us to help empower your science and drive your business. For more information about the QSight Triple Quadrupole LC/MS/MS, go to www.perkinelmer.com/qsight PerkinElmer, Inc. 940 Winter Street Waltham, MA 02451 USA P: (800) 762-4000 or (+1) 203-925-4602 www.perkinelmer.com For a complete listing of our global offices, visit www.perkinelmer.com/contactus Copyright 2017, PerkinElmer, Inc. All rights reserved. PerkinElmer is a registered trademark of PerkinElmer, Inc. All other trademarks are the property of their respective owners. 013847_01 PKI