Focus Series Peptide Synthesizers

Similar documents
Focus XC + 6 Microwave capability = Infinity Explore Infinite Possibilities. with the Infinity Microwave Peptide Synthesizer

An automated synthesis programme for drug discovery

Dr. OligoTM DNA / RNA / OLIGO SYNTHESIZERS

به نام خدا. New topics in. organic chemistry. Dr Morteza Mehrdad University of Guilan, Department of Chemistry, Rasht, Iran

PS3. Peptide Synthesizer.

l 4-minute cycle time l 90% solvent reduction Remarkably fast Automated Microwave Peptide Synthesizer

Rapid Microwave-Assisted CNBr Cleavage of Bead-Bound Peptides

SUPPORTING INFORMATION. Elevated Temperatures A Critical Comparison of

Perseverance. Experimentation. Knowledge.

aapptec 2. Set up a flask with a heating mantle and thermometer on an orbital shaker.

Microwave-Enhanced Solid Phase Peptide Synthesis. Jonathan M. Collins Bioscience Division CEM Corporation

Peptide Isolation Using the Prep 150 LC System

Everyday NMR. Innovation with Integrity. Why infer when you can be sure? NMR

Manual Solid Phase Peptide Synthesis Protocol (modified 12/14/16)

Continuous Flow-based Solid-phase Peptide Synthesiser

Process Safety. Process Safety and Hazard Assessment Avoiding Incidents in the Lab and in the Plant

RediSep Rf C18 Flash Column Loading Techniques

For Excellence in Organic Chemistry

INNOVATIVE ENGINEERING FOR SIMPLE OPERATION

Supporting Information for. PNA FRET Pair Miniprobes for Quantitative. Fluorescent in Situ Hybridization to Telomeric DNA in Cells and Tissue

SOPHAS - Speeding up the process of discovery and optimisation

Biotage 2012 Webinar series

High Pressure Chemistry. Hydrogenation & Catalysis Tools.

University Wet Chemistry Analyzer Packages

Pure Chromatography Consumables Pure flexibility. Pure specialization. Pure convenience.

High-Performance Continuous Flow Chemistry Systems. Robust Accurate Flexible Safe

Supporting Information

Quantos GraviPrep. Bye Bye, ml Hello, Quantos

Supporting Information

Supporting Information

Syro Wave Microwave & Parallel Peptide Synthesizer - The Best of Both Worlds

INNOVATIVE ENGINEERING FOR SIMPLE OPERATION

LABOTRON EXTRACTION & SYNTHESIS 2450 MHz

Drug Testing Solutions INDIKO DRUG TESTING ANALYZER. 1 P F

Thermo Scientific Orion Star T900 Series Laboratory Titrators. Potentiometric titrators for performing automated ph, redox, or ion titrations

10/18/2006. Biotage A Life Science Technology Company

MultiVap8: Automated concentration system

molecules ISSN

Level. Automate your processes Automate your lab Innovate with. sensing. EasyPREP. sample handler. Automated Sample Preparation.

NGS Made Easy. Optimize your NGS library preparation with the epmotion Automated liquid handling system

For purification/separation of organic and aqueous phases from a two phase mixture within a 96 or 24 array tube system

Test Method Development and Validation as Pertaining to Microtrac Particle Size Measuring Instruments

SIMPLICITY AND TECHNOLOGY THE LIASYS CLINICAL CHEMISTRY SYSTEMS FOR PHYSICIAN OFFICE LABORATORIES

Postsynthetic modification of unprotected peptides via S-tritylation reaction

Tides Las Vegas, May 17-20,2009 The Best of Both Worlds A Case Study in Harnessing Solid- and Liquid-Phase Peptide Synthesis

Product Information. Silicon Carbide Well Plates

Mag-Bind Soil DNA Kit. M preps M preps M preps

IRMS. perspective. Isotope Ratio Mass Spectrometry.

ChiroSolv EnantioPrep Kits Deliver Pure Enantiomers

The Benefits of Gravimetric Sample Preparation

GRIGNARD REACTION Synthesis of Benzoic Acid

Liberty Blue TM Automated Microwave Peptide Synthesizer. User Guide

SUPPLEMENTARY INFORMATION

Vapourtec UV-150 Photochemical Reactor. Application notes 37-39, 41-44, 47, 48

Supplementary Material Novel phosphopeptides as surface-active agents in iron nanoparticle synthesis

Supporting Information

AGrignard reaction, in which a reactant, A, is coupled with phenyl magnesium chloride, is used to

Oligo Click S ROTI kit for DNA labeling

PART I: Chemfile Creations:

Supporting Information

COMBINATORIAL CHEMISTRY IN A HISTORICAL PERSPECTIVE

Oligo Click M Reload ROTI kit for DNA labeling

BS-800 Modular System. Clinical Chemistry Solution

SUPPORTING INFORMATION

Microwave Synthesis Fourth generation systems

PS-PPh 3 -Pd. Polymer-Bound Triphenylphosphine-Pd(0) Technical Note 517. PdL n

Automating Wet Chemical Analysis. William Lipps Market Specialist for Water Analyzer Products December 11, 2008

Your Partner for Specialty Chemical Innovation & Technology

Kjeltec 2300 Analyzer Unit

Bruker Daltonics. EASY-nLC. Tailored HPLC for nano-lc-ms Proteomics. Nano-HPLC. think forward

110 Lowell Rd Hudson, NH USA Tel:

Module No. 31: Peptide Synthesis: Definition, Methodology & applications

Application Note PB 401. Improve HPLC Sample Preparation in an Analytical Laboratory A New Automated Sample Preparation Process

AppNote 5/2008. Automation of Sample Preparation Steps using a Robotic X-Y-Z Coordinate Autosampler with Software Control KEYWORDS ABSTRACT

DI 3500 Discrete Aoalvzer

Self-Assembly of Single Amino acid-pyrene Conjugates with Unique Structure-Morphology Relationship

References. Continuous Manufacturing Process Development Plant Realizations. Microinnova Engineering GmbH. Europapark Allerheiligen bei Wildon

ION CHROMATOGRAPHY SYSTEM S 150

General methods. RP-HPLC and LC-MS

high performance OPTIC 3 and applications a total analytical solution

Varian Galaxie Chromatography Data System for Preparative HPLC

Product Descriptions and Offerings

Astoria-Pacific proudly offers our rapid-t software for the ChemWell-T an easy-to-use, compact automated chemistry analyzer:

Automated Clinical Analyzer

RNA Transport. R preps R preps

1. Draw the structure of oxazolone formed upon activation of N-Acetylvaline

The recent biological and therapeutic discoveries of RNA have led to numerous alterations in the chemical synthesis

Synthesis of Peptide-Grafted Comb Polypeptides via Polymerisation of NCA-Peptides

Rational design of a hexapeptide hydrogelator for controlled-release drug delivery

Ensure reproducible Polymeric SPE workflow for high-throughput bioanalysis applications

Electronic supplementary information

LCTech GmbH Chromatographie

E.Z.N.A. MicroElute Clean-up Kits Table of Contents

Laird Thermal Systems Application Note. Precise Temperature Control for Medical Analytical, Diagnostic and Instrumentation Equipment

Bis sulfone Reagents. Figure 1.

473-SHX Dew Point Mirror

cobas c 111 analyzer Big analyzer performance in a small package

Compact Titration. Compact Titrator G20. One Click Titration Simple & Dependable

Today s Agilent Solutions for Determining Heavy Metals in Food using Atomic Spectroscopy

Transcription:

Focus Series Peptide Synthesizers aapptec is well known for its innovation and leadership in automated peptide synthesizers. aapptec technology has been an industry leader for the past 30 years around the world with: Research peptide synthesizers The 1 st mini-pilot scale synthesizer. The 1 st parallel multiple peptide synthesizer. The 1 st split-and-combine combinatorial library synthesizer. The 1 st synthesizer with heating, cooling and sonication. The 1 st Robotic Peptide Synthesizer. The Focus XC Series of peptide synthesizers is based upon the very successful Model 90, one of our most popular synthesizers since 1988. The Focus XC series was based on Model 90 s user input with modifications. Using our customers suggestions, the Focus XC is designed to be the premier peptide synthesis instrument. Wash, mix, deprotect and empty 6 reactors simultaneously Short cycle time Focus XC (2, 4, 6) (Research Instruments) The Focus XC research scale instruments are designed to efficiently synthesize 1 to 6 high quality compounds in parallel, yet still compact enough to fit on a laboratory bench. These instruments can prepare peptides in a scale range of 0.05 to 30 mmol depending on the reactor and instrument configuration and resin substitution. The Focus XC instruments are ideal for any research laboratory where efficiency, reliability, and high quality peptide products are important. They are invaluable tools for discovery research, synthetic methods, process development and even production for phase 1 and phase 2 clinical trials. Focus Xi (Personal Synthesizer) The Focus Xi is perfect for teaching laboratories or research laboratories with modest peptide needs. It is an affordable, dependable, single-reactor peptide synthesizer that can prepare up to 300 peptides a year. It is very flexible, with options including additional reactors, solvent/reagent lines, amino acid containers, heating/sonication modules and UV detection. www.aapptec.com l info@aapptec.com

Focus XCII (pna/dna/peptide) The Focus XCII is designed to meet the demands of continued medical research advancements. The Focus XCII can reliably deliver volumes as low as 200 µl to support pna, DNA and RNA synthesis. It can also be used for traditional solid phase peptide chemistry to produce small numbers of high quality peptides in small quantities. Focus XCIII (Production) The Focus XCIII is a fully-automated production scale synthesizer small enough to fit on a standard bench top. This instrument is capable of preparing hundreds of grams of peptide in a single synthesis. The Focus XCIII is the perfect instrument for preparing peptides for cgmp and up to 100 grams of peptide production. Options include additional solvent/reagent lines, 8 additional amino acid containers, heating and cooling reactors, and UV detection. Specifications Focus XC (2,4,6) 2, 4, or 6 Reactors Optional Reactor Sizes: 25, 50, 100, 200, 300 or 500mL 6 Solvent/Reagent Lines 24 Amino Acid Containers option (10mL, 40mL, 90mL or 250mL) Measuring and Preactivation Vessel option (15, 45, 90, or 250 ml) Optional UV Monitoring, Heating and Cooling Nitrogen/Mechanical Mixing Focus Xi 1 Reactor (Optional Sizes: 25, 50, 100, 200, 300 or 500mL) 5 Solvent/Reagent Lines (variable bottle sizes) 16 Amino Acid Containers (90mL) Optional: Up to 24 Amino Acids Nitrogen Mixing, Optional Mechanical Mixing Optional UV Monitoring, Heating and Cooling. Focus XCII Two Reactors (2-25mL) Two 6 Solvent/Reagent Lines (variable bottle sizes) 24 Monomer Containers (10-30mL) Mechanical and Nitrogen Mixing Optional UV Monitoring, Heating and Cooling Focus XCIII 1 Reactor Optional Reactor Sizes: 500mL, 1L, 2L, 3L, or 5L 6 Solvent/Reagent Lines 2 Amino Acid Containers (variable amino acid sizes) Optional: Up to 12 Amino Acids Optional UV Monitoring, Heating and Cooling Nitrogen/Mechanical Mixing 6309 Shepherdsville Rd. Louisville, KY 40228 l 502-968-2223

Reaction Vessel Design The Focus Instrument Series uses interchangeable reactors in sizes ranging from 5mL to 5L allowing for variable synthesis scales depending on the instrument s configuration. The reactors are made of glass for clear observation of the synthesis and easy access to the resin for manual additions or sampling. A durable glass frit ensures that the resin remains intact and in the reactor. Mixing The Focus Instrument Series utilizes variable speed wrist-action mixing, nitrogen bubbling, or a combination of both. Efficient Resin Washing The unique design of the reaction vessel allows the resin to be washed from the top of the reactor, through the resin, and then to the waste. The shower head spray feature efficiently and completely washes the sides of the reactors from the neck down, ensuring the resin remains in the bottom of the reactor so each bead makes uniform contact with the wash solvent. As an added feature, the user can also choose to wash the resin by delivering solvent to the bottom of the reactor. Solvent/Reagent Bottles Configurations of solvent, reagent and amino acids vary throughout the Focus Series models. The user has the option of customizing the configuration they desire. Heating Option The Focus Instrument Series has a heating option that allows the reaction vessel to be heated during reactions; the heating module applies heat only during the steps specified by the user, thus eliminating unnecessary heating that can damage heat sensitive sequences or sequence positions. Moderate heating during coupling has proven to be very beneficial for the synthesis of some peptides. Recently, conventional heating was shown to be as effective as microwaves in peptide synthesis. 1 1 Bacsa B, Horváti K, Bõsze S, Andreae F, Kappe CO J. Org. Chem. 2008, 73, 1532-42 The Spirit of Innovation

Focus Options Sonication Option Sonication has been shown to accelerate some reactions and can also yield products not obtainable by purely thermal activation. 2 Sonication has proven to disrupt aggregation and accelerate diffusion of reagents into the resin, thus speeding up coupling reactions; particularly useful for difficult couplings. aapptec offers an optional sonication module which applies ultrasound to the reaction vessels at user-specified intervals during synthesis. Crude Peptide 2 Hickenboth CR, et al. Nature, 2007, 446, 423-7 UV Monitoring Option The UV monitoring option identifies difficult deprotection positions in real-time and makes predefined adjustments to the synthesis protocols to optimize deprotection efficiency. This process minimizes deletion peptides that form when deprotection reactions are slow and the intermediate peptide resin is not fully de-protected before couplings. No more failed syntheses due to unexpected slow deprotections. Amino Acid/Reagent Containers The Focus Series Instruments are equipped with 16, 24, or 36 amino acid/reagent containers. Each amino acid container can be assigned to a single residue in the peptide sequence or used as stock amino acid reservoirs and accessed multiple times for multiple couplings for one or all peptides. The Focus Instrument has amino acid capacity to prepare six 80 amino acid peptides without interuption. Real-Time Feedback of the UV Monitoring System 1-ALA 2-VAL 3-ILE 4-PHE 5-PHE The Focus Series software allows the user to assign specific amino acids or reagents to each amino acid container as needed for the synthesis. The flexibility of the Focus Series allows for unattended completion of an entire synthesis, regardless of the scale or peptide length. The Focus Instrument Series can utilize either powder or pre-dissolved amino acids. The amino acid solution can be preactivated within the amino acid vial or a portion of the stock solution can be transferred to the measuring vessel for preactivation. All liquids are transferred under positive nitrogen pressure from a solvent or reagent container maintaining a completely inert atmosphere maintained by nitrogen or argon. aapptec is the Premier Peptide Source.

On-Line Cleavage On-instrument cleavage is a convenient, time-saving means of removing the product from the resin. The Focus Instrument Series can cleave products using any of the common cleavage protocols with the exception of HF based cleavage protocols. Cleavage with TFA, TFMSA, TMSOTF or specialized cleavage reagents can be easily performed on any of our Focus instruments without having to transfer the resin from the reaction vessel. All scavengers and additives utilized in common cleavage cocktails are compatible with the Focus instruments. Just prepare the cleavage mixture and place it in one of the amino acid/ reagent vials and the instrument will automatically agitate the mixture for a length of time specified by the user, then transfer the solution containing the cleaved product to a separate container. Product cleavage on the Focus instruments is easy and convenient without the losses encountered in transferring product resin from a reaction vessel to a cleavage vessel. The Focus instruments, with their flexibility, ease of use, multiple simultaneous synthesis capability, and convenient on-instrument cleavage, are productivity-enhancing tools suitable for any laboratory. RV to AA Three ways to Transfer Cleavage Product Solution The solution containing the cleaved product can be transferred by any one of the following ways: 1. It can be collected in a designated amino acid/reagent container. RV to RV 2. It can be transferred to another reaction vessel for further elaboration. 3. It can be sent to a flask or other container through one of the waste lines. The waste line can be flushed prior to cleavage or one of the waste lines can be dedicated for products only. RV to Flask 6309 Shepherdsville Rd. Louisville, KY 40228 l 502-968-2223

Focus Software Easy-To-Use Software The Focus Instrument Software has standard pre-loaded Boc and Fmoc protocols that allow any user to prepare high quality peptides. On-screen instructions direct users through every step of the synthesis process with point-and-click commands making operation simple. Experienced users can quickly create custom chemistries, such as special coupling protocols or alternative deprotection methods. The flexibility and versatility of the software makes the Focus Instrument Series the ultimate in peptide synthesizers. Reliability The Focus Instrument Series is a highly reliable system which utilizes proven technology. With simple preventive maintenance, your Focus Instrument will provide reliable and continuous service for many years. Easy-to-Use Software Each amino acid can be assigned separate coupling protocols Technical Support All of aapptec s instruments are backed by our unparalleled expertise in peptide chemistry. An experienced and qualified team of technical support personnel, engineers, and application chemists is dedicated to answering all of your questions related to peptide chemistry, instrument operations, or instrument applications. For more information, contact aapptec today: 6309 Shepherdsville Rd., Louisville, KY 40228-1027, U.S.A. Phone: 502.968.2223 Toll-free: 888.692.9111 Fax: 502.968.3338 Email: info@aapptec.com www.aapptec.com Visit www.aapptec.com for the full line of products.

Speeds up my work, simple to use, very good customer service. I like the Focus XC. Research Triangle International Easy to use, great flexibility. Great for scale up and long peptides. No drawbacks. University of Nebraska