Thermal Behavior and Demagnetizing Factor of Nd-Fe-B & other Magnets: Disadvantage and Advantage in Their Applications

Similar documents
Electrical to mechanical - such as motors, loudspeakers, charged particle deflection.

Reversible Temperature Coefficients

Stabilization and Calibration of Permanent Magnets

Measurement And Testing. Handling And Storage. Quick Reference Specification Checklist

A/m Air Gap Anisotropic BH Curve cgs Coercivity Curie Temperature Demagnetization curve Eddy Current Ferromagnetic Flux

Definitions of Terminology in Magnetics

TECHNotes. What is the Magnetic Hysteresis Loop

Doubly salient reluctance machine or, as it is also called, switched reluctance machine. [Pyrhönen et al 2008]

Analysis and Design of Electromagnetic Pump

Encoders. Understanding. November design for industry: Help clean up the ocean. Horizon failure forensics

Regular paper. Design and FE Analysis of BLDC Motor for Electro- Mechanical Actuator

DESIGN AND ANALYSIS OF AXIAL-FLUX CORELESS PERMANENT MAGNET DISK GENERATOR

Finite Element Model of a Magnet Driven Reed Switch

Switching Hall Effect Sensor Design Example Application: commutation sensor precision motor timing device to control electronic commutation.

Chapter 13 Principles of Electromechanics

Chapter 14. Optical and Magnetic Materials. 경상대학교 Ceramic Design Lab.

Following Load Lines to your Working Points, and Reluctance to Optimize: Coercing the Most Out of Your Magnets. Dr.

Electromagnetism. Topics Covered in Chapter 14:

Magnetic Counterforce for Insertion Devices*

TEMPERATURE EFFECTS ON MOTOR PERFORMANCE

Outer rotor eddy current heater for wind turbines

Analytical Model for Sizing the Magnets of Permanent Magnet Synchronous Machines

The Optimum Design of the Magnetic Orientation of Permanent Magnets for IPMSM under Hot Environments

APPLICATION OF ND 2 FE 14 B MAGNET IN THE LINEAR GENERATOR DESIGN ABSTRACT INTRODUCTION

Vacuum baking test of NdFeB permanent magnet material for ERL undulators *.

SYLLABUS(EE-205-F) SECTION-B

White Rose Research Online URL for this paper:

Estimate of Undulator Magnet Damage Due to Beam Finder Wire Measurements

Magnetic Fields

Standex-Meder Electronics. Custom Engineered Solutions for Tomorrow

Keywords: Electric Machines, Rotating Machinery, Stator faults, Fault tolerant control, Field Weakening, Anisotropy, Dual rotor, 3D modeling

Lecture 7: Synchronous Motor Drives

Neutron Irradiation Test Results of the RH1021CMW-5 Precision 5V Reference

The Nottingham eprints service makes this work by researchers of the University of Nottingham available open access under the following conditions.

This is a repository copy of Improved analytical model for predicting the magnetic field distribution in brushless permanent-magnet machines.

Designing an Efficient Permanent Magnet Generator for Outdoor Utilities İlhan Tarımer

Thermal Analysis & Design Improvement of an Internal Air-Cooled Electric Machine Dr. James R. Dorris Application Specialist, CD-adapco

M. Sc. Nikita Uzhegov

Standex-Meder Electronics. Custom Engineered Solutions for Tomorrow

CHAPTER 20 Magnetism

Robust optimal design of a magnetizer to reduce the harmonic components of cogging torque in a HDD spindle motor

Displacement Current. Ampere s law in the original form is valid only if any electric fields present are constant in time

Introduction. Neutron Effects NSEU. Neutron Testing Basics User Requirements Conclusions

Chapter 29. Magnetic Fields due to Currentss

Magnetism & Electromagnetism

CPPM Mahine: A Synchronous Permanent Magnet Machine with Field Weakening

Note that a current-carrying solenoid produces a dipole field similar to that of a bar magnet. The field is uniform within the coil.

III.Sources of Magnetic Fields - Ampere s Law - solenoids

Development of axial flux HTS induction motors

AXIAL FLUX INTERIOR PERMANENT MAGNET SYNCHRONOUS MOTOR WITH SINUSOIDALLY SHAPED MAGNETS

PHYSICS 30 ELECTROMAGNETISM ASSIGNMENT 3 VERSION:0

Proposal of short armature core double-sided transverse flux type linear synchronous motor

Revision Guide for Chapter 15

3 d Calculate the product of the motor constant and the pole flux KΦ in this operating point. 2 e Calculate the torque.

Neutron Irradiation Test Results of the RH1009MW 2.5V Reference

The GENERATION, MEASURING TECHNIQUE AND APPLICATION OF PULSED FIELDS. R.Grössinger

ELECTRIC MACHINE TORQUE PRODUCTION 101

Retrofit design of a line-start permanentmagnet synchronous machine

Dr. N. Senthilnathan (HOD) G. Sabaresh (PG Scholar) Kongu Engineering College-Perundurai Dept. of EEE

CHAPTER 3 INFLUENCE OF STATOR SLOT-SHAPE ON THE ENERGY CONSERVATION ASSOCIATED WITH THE SUBMERSIBLE INDUCTION MOTORS

RADIATION EFFECTS ON HIGH TEMPERATURE SUPERCONDUCTORS

EDEXCEL NATIONAL CERTIFICATE/DIPLOMA UNIT 5 - ELECTRICAL AND ELECTRONIC PRINCIPLES NQF LEVEL 3. OUTCOME 3 - MAGNETISM and INDUCTION

13.5 Conductor in a Magnetic Field The Motor Principle

1. An isolated stationary point charge produces around it. a) An electric field only. b) A magnetic field only. c) Electric as well magnetic fields.

On Permanent Magnet Material Testing. 1. Permanent Magnet magnetization.

Analysis of Anti-Notch Method to the Reduction of the Cogging Torque in Permanent Magnet Synchronous Generator

PERFORMANCE IMPROVEMENT OF THREE PHASE INDUCTION MOTOR USING SUPER MAGNETIC MATERIAL

Operation of an Electromagnetic Trigger with a Short-circuit Ring

Study and Characterization of the Limiting Thermal Phenomena in Low-Speed Permanent Magnet Synchronous Generators for Wind Energy

Accurate Joule Loss Estimation for Rotating Machines: An Engineering Approach

R. Ravaud and G. Lemarquand Laboratoire d Acoustique de l Universite du Maine UMR CNRS 6613, Le Mans, France

Magnetism. a) Ferromagnetic materials are strongly attracted to magnets. b) Paramagnetic materials are weakly attracted to magnets

STAR-CCM+ and SPEED for electric machine cooling analysis

Jerad P. 10/1/2015. Motor Thermal Limits on Torque Production (Frameless Motor Level)

Neutron testing of the IS1009RH voltage reference

MAGNETS AND INSERTION DEVICES FOR THE ESRF II

Loss Minimization Design Using Magnetic Equivalent Circuit for a Permanent Magnet Synchronous Motor

Neutron Irradiation Test Results of the RH3080MK Adjustable 0.9A Single Resistor Low Dropout Regulator

Thermal vs. Power Loss Efficiency Considerations for Powder Core Materials. Christopher Oliver Nien Teng Micrometals, Incorporated

High-temperature superconducting magnet for use in Saturated core FCL

Analysis of Halbach magnet array and its application to linear motor

The Physics of Ferromagnetism

Finite Element Analysis of Hybrid Excitation Axial Flux Machine for Electric Cars

Unit WorkBook 3 Level 4 ENG U3 Engineering Science LO3 Engineering Materials 2018 UniCourse Ltd. All Rights Reserved. Sample

Chapter 4: Magnetic Field

Physics Form 5 Syllabus

Third harmonic current injection into highly saturated multi-phase machines

Module-16. Magnetic properties

APPLICATION OF THE FINITE ELEMENT METHOD TO MODEL THE NONLINEAR VOICE COIL MOTION PRODUCED BY A LOUDSPEAKER MAGNET ASSEMBLY.

B for a Long, Straight Conductor, Special Case. If the conductor is an infinitely long, straight wire, θ 1 = 0 and θ 2 = π The field becomes

Version The diagram below represents lines of magnetic flux within a region of space.

Magnetic Fields due to Currents

MAGNETIC COUPLINGS WITH CYLINDRICAL AND PLANE AIR GAPS: INFLUENCE OF THE MAGNET POLARIZATION DIRECTION

MAGNETIC MATERIALS. Fundamentals and device applications CAMBRIDGE UNIVERSITY PRESS NICOLA A. SPALDIN

Design and Analysis of 42-V Permanent-Magnet Generator for Automotive Applications

11/21/2011. The Magnetic Field. Chapter 24 Magnetic Fields and Forces. Mapping Out the Magnetic Field Using Iron Filings

EFFECTS OF MAGNETIC MATERIAL ON PERFORMANCE OF PERMANENT MAGNET SYNCHRONOUS MACHINES RYAN GRAVES

Optimal Design of PM Axial Field Motor Based on PM Radial Field Motor Data

Basics of Permanent Magnet - Machines

Design of a laminated-steel magnetic core for use in a HT-SMES

Transcription:

Thermal Behavior and Demagnetizing Factor of Nd-Fe-B & other Magnets: Disadvantage and Advantage in Their Applications Christina H Chen University of Dayton, USA, Magnet Energy Corp., USA Pengpeng Yi Ningbo Songke Magnetic Material Co., Ltd., Zhejiang 1

Outline q Describing the thermal behavior and the demagnetizing factor of Nd-Fe-B and other magnets. q Discussing the disadvantages and advantage for their applications. The disadvantages include high magnetic flux loss at elevated temperatures or exposing to various radiations-induced heat. q The high temperature coefficients of α (B) and β (H ci ) are the major reasons for the addition of Dy and other heavy RE elements into Nd-Fe-B for PM motor applications. q The advantages include thermal magnetization using a significant smaller magnetic field to saturate the magnets. 2

Introduction q q q Nd-Fe-B and other magnets are in high demand in today s sustainable energy applications. The global market for these magnets is expected to reach USD 31 billion by 2020. Growth of global automobile industry is expected to be a key-driving factor for permanent magnets market. Various components such as motors, alternators and gearbox require permanent magnets for their mechanism. Understanding the behavior of the permanent magnets should help many designers to design and make better PM motors. 3

Thermal Behavior of Nd-Fe-B & Other Magnets: Thermal Expansion Coefficients (1) q Thermal expansion coefficients α in both directions: The degree of thermal expansion anisotropy (TEA) is defined as the ratio γ = α( )/α(//). q The TEA data are actual very useful in guiding material manufacturing and device designing. For example, SmCo 5 has a very large TEA with γ = 2.54, which results in extremely difficulty to make radially oriented, anisotropic magnetic rings for SmCo 5. 4

Thermal Behavior of Nd-Fe-B & Other Magnets: Thermal Expansion Coefficients q q q @ ~ 150C: Nd 2 Fe 14 B phase changes from a uniaxial (easy-axis) to an easy-cone: thermal expansion coefficients changes: a consideration for some applications at extremely low temperature @ ~310C: Curie point T c. Thermal expansion coefficients change dramatically near T c. A consideration for melting the alloys: In order to make the melting crucible last longer, it should not be cooled down below 310C, and continuous melting is desired. The TEA [γ = α( )/α(//)] of NdFeB also results in a difficulty to make radially oriented, anisotropic magnetic rings. 5

Thermal Behavior of Nd-Fe-B & Other Magnets: Temperature Coefficients Temperature dependence of energy product and coercivity for NdFeB and other magnets (data were obtained in year 2000, and the values in parentheses are the (BH) max at 25 C) 6

Thermal Behavior of Nd-Fe-B & Other Magnets: Thermal Magnetic Loss vs Magnets Geometry & Type Magnetic Flux Loss (%) 20 0-20 -40-60 -80-100 -120 NdFeB L/d~0.14 Alderman NdFeB L/d=1.2 Chen et al. T =266 C T L >310 C* 1.E+13 10 13 1.E+14 10 14 1.E+15 10 15 1.E+16 10 16 1.E+17 10 17 1.E+18 10 18 1.E+19 10 19 1.E+20 10 Neutron Fluence (neu/cm 2 ) All reports had Neutron E = 0.1-10 MeV. Neutron flux: 4x10 12 (Cost) and 2.1x10 13 n/(cm2.s) (Chen et al) Sm-Co 2:17 T300C & T500C L/d=1.2 (Chen et al.) Brown 2:17 Hardekopf 2:17 NdFeB[ 7] L/d=3.5 T = 77 C T L =?* T =153 C, T L =? * Cost et al. q T L is localized temperature at momentary time q Radiation damage studies have been performed under a variety of radiation fields, such as neutron, electron, proton, and gamma. q Sm-Co magnets have been found to be more radiation resistant than Nd-Fe-B magnets, which are actually attributed to their higher Curie temperature and superior thermal properties q All the losses associated with radiation are caused by radiation-induced heat. q The losses are related to the samples geometry too 7

Thermal Behavior of Nd-Fe-B & Other Magnets: Thermal Magnetic Loss vs Magnets Geometry & Type Magnetic Flux Loss (%) 20 0-20 -40-60 -80-100 E = 0.1 to 10 MeV L/d = 8.9 L/d = 4.8 L/d = 4.4 L/d = 3.1 L/d = 2.0 L/d = 0.9 L/d = 0.4 1.E+13 10 13 1.E+14 10 14 1.E+15 10 15 1.E+16 10 16 1.E+17 10 17 1.E+18 10 18 1.E+19 10 19 1.E+2 10 20 Neutron Fluence (neu/cm 2 ) Recorded T = 78 C, T L was likely ~ 160 C (Hci >17kOe) If T L Tc, the loss will be 100% for all the samples Cost et al.(1989) Re-plotted using a scale comparable in this presentation q T L is localized temperature at momentary time caused by radiation q It is very clearly that the magnetic losses caused by radiation-induced heat also depend on the L/D, which is directly related to demagnetizing factor. The dominant factor for heat tolerance is the thermal stability of magnets, determined by 3 factors: q the T C q Intrinsic coercivity H ci of magnets and the temperature coefficient of H ci, which determine the linearity of the B-H normal curve; q The load line of the magnet, related to the L/D ratio or the demagnetizing factor of the magnets; 8

Thermal Behavior of Nd-Fe-B & Other Magnets: Thermal Magnetic Loss vs Magnets Geometry & Type Magnetic Flux Loss (%) 2x 10 11 2x10 12 2x10 13 2x10 14 Fluence in proton/cm 2 20 Sm-Co 2:17-R26H-L/d=0.2 Tc=820ºC 0-20 -40-60 -80-100 N48-T c =310ºC H ci =14.4 koe Irradiated with 200 MeV Protons 1.E+04 10 4 1.E+05 10 5 1.E+06 10 6 1.E+07 10 7 1.E+08 10 8 1.E+09 10 9 Ito et al. NIM B 183(2001)323 Proton Dose ( Rad) N32Z L/d=0.2 N48 L/d=0.4 N48 L/d=0.2 N32Z H ci =31.5 koe N48 L/d=0.7 T c =355ºC L/d=0.4 Effects of Intrinsic coercivity and L/D on the thermal loses induced by Proton radiation on the Nd-Fe-B magnets with different Dy contents and different L/D values : Hci (koe) Loss@ 2x10 6 L/D =0.2 Loss@ 2x10 6 L/D =0.7 N48 N32Z 14.4 31.5 80% 15% 38% 0% 9

Consideration of Demagnetizing Factor Permeance coefficient (or a load line) Demagnetization curves of samples of a Nd-Fe-B and a Sm-Co T500C. Sm-Co is plotted with dotted lines, and the Nd 13 Dy 2 Fe 77 B 8 is plotted with solid lines q Theoretically, as long as the T < T C, a magnet should fully recover its magnet strength after cooling down to room T, if it had a perfect linear extrinsic demag curve (B-H) at the T exposed. q To maintain a linear B-H curve, a high H ci and a low-temperature coefficient of H ci are required. q If a magnet does not have a linear B- H curve, a large permeance coefficient (or a higher load line) is required. q The permeance coefficient B/H, or Load Line, is a critical factor in magnetic design, which is a function of the L/D ratio for a stand-alone magnet. 10

Consideration of Demagnetizing Factor An extreme example @ 250 C 0.30 + (A) SmCoT500C 21MGOe @25 C (A) @25 C after @250 C (A) @250 C 0.27 + 0.24 + 0.21 + 0.18 + 0.15 + 0.12 + (B) Nd13Dy2Fe77B8 35MGOe @25 C 0.09 + (B) @25 C after @250 C (B) @250 C 0.06 + 0.03 + 0.00 + Magnetic Flux Density (Tesla) B(T) (A). Sm-Co T500C(solid lines) 0.4 (A) @25 C before & after 250 C (A) @250 C 0.2 diameter =5mm 0.0-2 -1 00 1 12 3 24 5 6 3 Magnetic flux density on the section across the diameter. Bottom: From 25 C to 250 C: Sm-CoT500C was fully recovered with unnoticeable loss, and Nd13Dy2Fe77B8 still has ~72% loss. (B) @250 C -3 Top: After cooling down to 25 C: (B) @25 C after 250C 0.1 Thermal behaviors of Nd13Dy2Fe77B8 and Sm-Co-T500C with L/D = 1.25 (B/H = 3.6) Flux density along a line 2 mm above the magnet :Sm-Co-T500C has 9.3% loss, and Nd13Dy2Fe77B8 has ~89% loss. (B) @25 C 6.25mm 0.3 (B). Nd 13Dy2Fe 77B8 This is an extreme example @ 250 C 7 8 4 9 10 5 11 Location along a line 2 mm above the magnet (mm) 11

The Relationship of Permeance Coefficient B/H, Load line, Demagnetizing Factor, and L/D This magnet has a high H ci and a straight B-H curve, which is ideal for motor applications, and a small L/D can be used. The permeance coefficient B/H is a critical factor in magnetic design, which is a function of the L/D ratio for a standalone magnet. The plot on the left illustrates these terminologies: the intersection of a Load Line and the B-H normal curve is defined as the Operating Point. The slope of the line is referred to as the Permeance Coefficient (Pc = B d / H d ). The demagnetizing factor is defined in equations (1) and (2) in Parker s book *. * Rollin. J. Parker, Advances in Permanent Magne1sm. ISBN 0-471- 82293-0, by John Wiley & Sons, (1990). 12

The Relationship of Permeance Coefficient B/H, Load line, Demagnetizing Factor, and L/D To maintain stable performance, a minimum L/D ratio is required, which must correspond to the B/H Load Line above the knee of the B-curve. Next page gives further illustration on the requirement of linear B-H curve for motor application. This magnet has a low H ci and non-linear B-H curve, which is not suitable for motor application. Note: The Recoil Permeability µ r : Typical values are ~1.05 for Ferrite, Sm-Co and NdFeB. Bonded Neo magnets range from ~ 1.12 to 1.70, depending upon grade. This topic is not in the scope of this presentation. 13

The Relationship of Permeance Coefficient B/H, Load line, Demagnetizing Factor, and L/D To maintain stable performance, a minimum L/D ratio is required, which must correspond to the B/H Load Line above the knee of the B-curve. This plot gives further illustration on the requirement of linear B-H curve for motor application. q Demagnetization curves for a Nd-Fe-B sample with intrinsic coercivity > 25 koe at 25 C to 200 C: q The 5 B-H curves are linear from 25 to 125 C, and the 3 B-H curves at 150, 175, and 200 C are non-linear with obvious keens. q In dynamic applications with elevated temperature, (such as in PM motors) this magnet should be used at T 125 C. q A knee will result in large irreversible loss after exposing to a higher temperature. 14

The Relationship of Permeance Coefficient B/H, Load line, Demagnetizing Factor, and L/D q In actual magnetic devices, the demagnetizing field depends on the demagnetizing factor N, which in turn depends on the geometry of the magnets and their permeability. q Theoretically the demagnetizing factor can be calculated precisely only for the case of an ellipsoidal sample; for other regular geometries, it must be determined experimentally or calculated numerically subject to certain assumptions. Errors are inevitable for such calculations. There are various methods to determine the demagnetizing factors, which can be found in many references. q A convenient method has been used by many in the industry, which is described in Rollin J Parker s book of Advances in Permanent Magnetism. Parker summarized the relationship of permeance coefficients and various magnet shapes, such as rings, rectangles, which are plotted in the next 4 figures. The formulas for calculating the plots are listed in the figures respectively. 15

The Relationship of Permeance Coefficient B/H, Load line, Demagnetizing Factor, and L/D The permeance coefficient B/H vs. L/D for cylinders with axial magne\za\on The permeance coefficient B/H vs. D/W for cylinders with diametric magne\za\on 16

The Relationship of Permeance Coefficient B/H, Load line, Demagnetizing Factor, and L/D The permeance coefficient B/H vs. L/D for tubular magnets with axial magne\za\on The permeance coefficient B/H vs. L/T for rectangular bars with magne\za\on along L direc\on 17

The Relationship of Permeance Coefficient B/H, Load line, Demagnetizing Factor, and L/D q A rule of the thumb is that a magnet with a smaller L/D ratio will have a larger irreversible magnetic loss at elevated temperature, compared to a magnet with a larger L/D ratio. q In order to estimate the relative irreversible magnetic loss, some engineers usually use a simplified calculation as shown below for some frequently used shapes in PM motors, such as arc shaped magnets. 18

The large Temperature-Coefficient can be Used in Thermal Magnetizing q If it requires two times of intrinsic coercivity (2 x H ci ) to saturate a magnet (actually ~99% of saturation), a minimum magnetizing field is required to saturate a magnet. q At 25 C, for typical Sm-Co 2:17 magnet, a high coercivity Nd-Fe-B, and a Ferrite magnet, the required minimum magnetizing field is 7.0 T, 5.4T, and 0.5 T respectively. q By using the thermal behavior, we can reduce the minimum magnetizing field significantly for Nd-Fe-B magnets since they have large temperature coefficient. 19

Large Power Surface-Mounted PM Motors Using Post-Assembly Magnetization at 150 C q Rare-earth PM brushless motors are usually assembled with the magnets pre-magnetized. However, as the motor size & output power é é, the handling of the pre-magnetized components can be difficult & it increases the processing cost. q Hence, the post-assembly magnetization represents a potential solution. 1.0 @25C: Mmin =5.4T, and @200C: Mmin =1.2T q By using the thermal behavior, we can reduce the min. magnetizing field greatly for Nd-Fe-B PM motor since the large temperature coefficient. (a) distribution of a motor s magnetic flux lines (output 2000 amperes): it can be seen that the wiring of the windings can indeed produce the correct charge and magnetic poles; (b) the magnetic field strength distribution, wherein the unit M is 106 A / m. * IEEE Trans. on Industrial Electronics, 57( 10) pp. 3376-3384, 2010. 20

Summary q The thermal behaviors of Nd-Fe-B and other magnets their disadvantages and also advantages for their applications. q The disadvantages include high magnetic flux loss at elevated temperatures or exposing to various radiationsinduced heat. q The high temperature coefficients of α (for induction B) and β (for coercivity Hci ) are the major reasons for the addition of dysprosium and/or other heavy rare earth elements into Nd-Fe-B for PM motor applications. q The advantages include thermal magnetization using a significant smaller magnetic field to saturate the magnets. 21