Laser induced fluorescence

Similar documents
Because light behaves like a wave, we can describe it in one of two ways by its wavelength or by its frequency.

Experiment 9. Emission Spectra. measure the emission spectrum of a source of light using the digital spectrometer.

Characterisation & Use of Array Spectrometers

LASER. Challenging MCQ questions by The Physics Cafe. Compiled and selected by The Physics Cafe

Lab 10: Spectroscopy & the Hydrogen Atom Phy208 Fall 2008

AS 101: Day Lab #2 Summer Spectroscopy

Ruby crystals and the first laser A spectroscopy experiment

Any first year text, sections on atomic structure, spectral lines and spectrometers

Some Topics in Optics

SUPPLEMENTARY INFORMATION

Spectroscopy. Experimental Optics. Contact: Lisa Kaden Malte Siems

Chemistry Instrumental Analysis Lecture 5. Chem 4631

n ( λ ) is observed. Further, the bandgap of the ZnTe semiconductor is

DAY LABORATORY EXERCISE: SPECTROSCOPY

Model Answer (Paper code: AR-7112) M. Sc. (Physics) IV Semester Paper I: Laser Physics and Spectroscopy

Laboratory #29: Spectrometer

Experiment 3 1. The Michelson Interferometer and the He- Ne Laser Physics 2150 Experiment No. 3 University of Colorado

Practical 1P4 Energy Levels and Band Gaps

Lecture 0. NC State University

ATOMIC SPECTRA. Objective:

The Emission Spectra of Light

Chem Homework Set Answers

Practical 1P4 Energy Levels and Band Gaps

Diffraction Gratings, Atomic Spectra. Prof. Shawhan (substituting for Prof. Hall) November 14, 2016

Atomic Spectra HISTORY AND THEORY

ATOMIC SPECTRA. To identify elements through their emission spectra. Apparatus: spectrometer, spectral tubes, power supply, incandescent lamp.

Astronomy. Optics and Telescopes

Lab 5: Spectroscopy & the Hydrogen Atom Phy248 Spring 2009

Single Emitter Detection with Fluorescence and Extinction Spectroscopy

Chemistry 2. Molecular Photophysics

Preview from Notesale.co.uk Page 1 of 38

Reference literature. (See: CHEM 2470 notes, Module 8 Textbook 6th ed., Chapters )

Absorption photometry

SUPPLEMENTARY INFORMATION

Fall 2014 Nobby Kobayashi (Based on the notes by E.D.H Green and E.L Allen, SJSU) 1.0 Learning Objectives

Observation of Atomic Spectra

High Resolution Optical Spectroscopy

Atomic spectra of one and two-electron systems

Laboratory 3&4: Confocal Microscopy Imaging of Single-Emitter Fluorescence and Hanbury Brown and Twiss setup for Photon Antibunching

UV-Vis optical fiber assisted spectroscopy in thin films and solutions

where c m s (1)

To determine the wavelengths of light emitted by a mercury vapour lamp by using a diffraction grating.

What is spectroscopy?

Chemistry 524--Final Exam--Keiderling May 4, :30 -?? pm SES

Stimulated Emission Devices: LASERS

LASER. Light Amplification by Stimulated Emission of Radiation

PHYS General Physics II Lab The Balmer Series for Hydrogen Source. c = speed of light = 3 x 10 8 m/s

25 Instruments for Optical Spectrometry

Experiment #4 Nature of Light: Telescope and Microscope and Spectroscope

Course Details. Analytical Techniques Based on Optical Spectroscopy. Course Details. Textbook. SCCH 211: Analytical Chemistry I

The Quantum Model of the Hydrogen Atom

Atomic Spectroscopy. Absorption and Emission Spectra. Lodovico Lappetito. SpettroscopiaAtomica - 15/07/2015 Pag. 1

EMISSION SPECTROSCOPY

object objective lens eyepiece lens

The Spectrophotometer and Atomic Spectra of Hydrogen Physics 246

Physics 476LW Advanced Physics Laboratory Atomic Spectroscopy

JABLONSKI DIAGRAM INTERACTIONS BETWEEN LIGHT AND MATTER LIGHT AS A WAVE LIGHT AS A PARTICLE 2/1/16. Photoelectric effect Absorp<on Emission ScaDering

Design and Development of a Smartphone Based Visible Spectrophotometer for Analytical Applications

Atomic Spectra. d sin θ = mλ (1)

Edward S. Rogers Sr. Department of Electrical and Computer Engineering. ECE318S Fundamentals of Optics. Final Exam. April 16, 2007.

Astronomy 203 practice final examination

Advanced Spectroscopy Laboratory

APAS Laboratory { PAGE } Spectroscopy SPECTROSCOPY

Fluorescence Workshop UMN Physics June 8-10, 2006 Quantum Yield and Polarization (1) Joachim Mueller

Lab 11: Must what goes in be the same as what comes out? Spectroscopy & Fluorescence in Chlorophyll.

LASERS AGAIN? Phys 1020, Day 17: Questions? LASERS: Next Up: Cameras and optics Eyes to web: Final Project Info

MODERN OPTICS. P47 Optics: Unit 9

( J s)( m/s)

Complete the following. Clearly mark your answers. YOU MUST SHOW YOUR WORK TO RECEIVE CREDIT.

1. Transition dipole moment

Analytical Chemistry II

Experiment AM3b: Raman scattering in transparent solids and liquids

Emission Spectrum of Atomic Gases. Prelab Questions

Chapter 7. The Quantum- Mechanical Model of the Atom. Chapter 7 Lecture Lecture Presentation. Sherril Soman Grand Valley State University

hν' Φ e - Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous?

What can laser light do for (or to) me?

Spectroscopy. Page 1 of 8 L.Pillay (2012)

Chapter-4 Stimulated emission devices LASERS

Stray Light Rejection in Array Spectrometers

Experiment 24: Spectroscopy

The Grating Spectrometer and Atomic Spectra

Population inversion occurs when there are more atoms in the excited state than in the ground state. This is achieved through the following:

Determination of bandwidth and beamwidth of a Rhodamine 6G dye laser using different optical setups

Lab #13: Polarization

Laser Basics. What happens when light (or photon) interact with a matter? Assume photon energy is compatible with energy transition levels.

(i) Show that the energy of a single photon is about 3 x J.

LASERS. Dr D. Arun Kumar Assistant Professor Department of Physical Sciences Bannari Amman Institute of Technology Sathyamangalam

Reduction procedure of long-slit optical spectra. Astrophysical observatory of Asiago

Chem 155 Midterm Exam Page 1 of 10 Spring 2010 Terrill

print first name print last name print student id grade

Instructor: Welcome to. Phys 774: Principles of Spectroscopy. Fall How can we produce EM waves? Spectrum of Electromagnetic Radiation and Light

Visualization of Xe and Sn Atoms Generated from Laser-Produced Plasma for EUV Light Source

Detection of X-Rays. Solid state detectors Proportional counters Microcalorimeters Detector characteristics

Laboratory Atomic Emission Spectrum

What do we study and do?

EXPOSURE TIME ESTIMATION

2. Discrete means unique, that other states don t overlap it. 3. Electrons in the outer electron shells have greater potential energy.

Investigating the Zeeman Effect in Mercury. Luke Pomfrey

Astr 2310 Thurs. March 3, 2016 Today s Topics

LC-4: Photoelectric Effect

Transcription:

Report experiment 1 by 4-7 February 22, id#471917

Summary Several measurements are made around laser induced fluorescence (LIF). First the system was calibrated. The resolution of the spectrograph was found to be.85 ±.2 nm. The theoretical resolution λ =.54 nm is smaller, because only a part of the error sources were part of the computation. Then the fluorescence, absorbtion and transmission spectrum of a rhodamine 6G solution were measured. The fluorescence peak wavelength is 57 nm, which corresponds to the orange color of the solution. Also the spectrum was measured using a yellow instead of a green laser. This showed that the absorbtion of yellow was much lower than that of green and the energy of fluorescing photons were lower. By translation the solution perpendicular to the laser-beam and forcing the fluorescing photons to travel through the solution longer, the concentration of rhodamine 6G could be computed: n =.141 ±.5 mmol l 1. The fluorescence efficiency was computed roughly by combining several measurements. This resulted in F =.17. The expected value was F 1. Finally some LIF measurements were done on a green leave. The qualitative result was that photoinhibition occurs, but there are also other processes causing fluorescence, albeit at other wavelengths.

CONTENTS 3 Contents 1 Introduction 4 2 Theory 5 2.1 Fluorescence.................................. 5 2.2 Absorbtion................................... 5 2.3 CCD....................................... 5 2.4 Spectrometer.................................. 6 2.5 Photosynthesis and fluorescence........................ 6 3 Experimental setup 7 3.1 Efficiency.................................... 7 4 Results 8 4.1 Calibration................................... 8 4.2 Absorbtion, transmission and LIF....................... 9 5 Discussion 11 5.1 Calibration................................... 11 5.2 Absorbtion, transmission and LIF....................... 11 6 Conclusions 13 A Measured spectrum of Ne 14 B Background measurement spectrum 15

1 Introduction 4 1 Introduction (LIF) is the optical emission from molecules that have been excited to higher energy leves by absorption of photons. One of the most frequently used applications of LIF is measuring a biological preperation with a dye. A fluorescing dye is chosen which binds to specific structures inside a cell, so that when the preperation is lit by a laser, an image of the structures can be made. Sometimes not even a dye is needed but already part of an organism, for example photosynthesis.

2 Theory 5 2 Theory 2.1 Fluorescence In an atom or molecule are many different energy levels in which an electron can be. Electrons tend to take positions with the lowest energy, this is called the ground state of the atom or molecule (S). When a photon is absorbed, an electron can be excited to a higher energy level (S1). Inside an energy level are smaller energy differences caused by rotation (J) and vibration (V). (LIF) is a process of (at least) two steps. First an electron is excited by absorbstion of a photon (upward arrow in figure 1). The energy of the electron is the previous energy of the electron plus the energy of the photon. Then the electron falls back to the ground state, emitting a photon of energy hν fluor. (downward arrow in figure 1). However, after step one the electron can undergo rotation and vibration transitions inside S1, before falling back to S. 2.2 Absorbtion V=3 V=2 V=1 V= hv laser V=3 V=2 V=1 V= J=2 J=1 J= S1 hv fluor. S Figure 1: Energy levels, LIF When a lightwave travels through a solution, the energy of the wave is gradually dissipated as the wave advances through it, so that the light intensity is a function of the thickness: I(x) = I e nεx, (1) where I is the intensity at x =, n is the concentration and ε is the molar extinction coefficient, which is a measure for the absorbtion of a certain molecule in the solution. 2.3 CCD A lineair CCD consist of a row of light-sensitive elements (pixels). When photons are absorbed in the vicinity of the junction, the electron-hole pairs are seperated by a builtin electric field (obtained by doping a semiconductor), causing a change in voltage, the photovoltaic effect. The efficiency of this proces is called the quantum efficiency Q. Pixels of a CCD are connected in series, so the whole CCD can be read out sequentially like a shift register. The number of measured counts N e consists of three components: N e = QN f + I d t + N read, (2) where N f is the number of photons that reached the pixel, I d is the dark current (spontaneous charging of a pixel), t is the measurement interval and N read is the error caused by reading the CCD.

2 Theory 6 2.4 Spectrometer A spectrometer is a device for measuring spectral lines of light. The central element of the spectrometer is the grating, causing light of different wavelengths to reflect on a different angle. Light from the entrance slit is directed to a first concave mirror with focal distance f, which collimates the light incident on the grating (see figure 2). The diffracted light is incident on a second concave mirror, which then focuses the spectrum at the CCD, resulting in a 1-to-1 image of the entrance slit. As the grating is rotated, the dispersed spectrum moves across the CCD.[2] The resolution of the spectrometer is dependent on the linedistance of the slit a, the focal Figure 2: Optical configuration of the MS125 spectrograph distance f of the first mirror, the width d pixel of a CCD pixel, the width d slit of the entrance slit and the angle of reflection between light beam and grating: λ = (d slit + d pixel )a cos θ. (3) f The total bandwidth is given by formula 4, where W is the width of the CCD: λ max λ min = W a cos θ. (4) f 2.5 Photosynthesis and fluorescence Photosynthesis is a process used by plants to obtain energy from light. In so called antennae molecules are excited by incoming photons and transported to a reaction centre, where further reactions occur. There are two types of reaction centres: PS I and PS II. In both types does fluorescence occur, but on different wavelengths. When a plant is lit excessively, photoinhibition [3] (also called photoprotection [4]) occurs, which obstructs photosynthetic electron transport between antennae and reaction centers, and slows down the photosynthesis. The energy is converted to heat and other chemical reactions, including decreasing the ph. This results in oxidative damage of the cells, so the reaction centers don t get overloaded.

3 Experimental setup 7 3 Experimental setup Some calibration measurements on the ccd and spectrometer are done first. The dark current is measured by reading the CCD when all light sources are turned off. This is done with different integration times (measurement intervals). A neon lamp is put in front of the spectrometer and the orientation of the grating inside the spectrometer is adjusted so that wavelengths between 5 and 8 nm are being projected on the CCD. The CCD can then be calibrated by comparing a measurement of the neon spectrum with known spectral lines. For the measurement of the absorbtion of rhodamine 6G the setup of figure 3 is build. By turning off the halogen lamp the background signal is measured. Then the halogen lamp is turned on, but no sample is placed in the cuvet. After measuring this, the cuvet with a rhodamine 6G solution is placed and the spectrum is measured again. The absorbtion spectrum can be derived from those three spectra. A green leave is used to do experiments on photosynthesis. The cuvet in in figure 4 is substituted for a sample of a leave. It is aligned such, that only light from fluorescence is caught by the lenses and led into the spectrometer. In this setup the leave sample is moved so a certain spot will be lit by the Halogen lamp Cuvet D A6 A1 Spectrometer CCD Figure 3: Setup for absorbtion measurements. A=achromatic lens, D=diafragm. Cuvet A6 A1 F1 M2 D2 D1 m Fluorescence The setup of figure 4 is build to do LIF measurements. The laser has a wavelength of 543.5 nm. The fluorescence spectrum of rhodamine 6G is measured. Also the effect of horizontal and vertical translation of the cuvet is measured. Then the spectrum is measured with a yellow (λ = 594.1 nm) laser. Spectrometer CCD L a s e r M1 Figure 4: Setup for LIF measurements. M=mirror, F=lens, A=achromatic lens, D=diafragm. laser. Then the laser is turned on and after waiting for t l seconds the spectrum is measured. This is done for different values of t l, each measurement at a different spot on the leave. 3.1 Efficiency Not every photon that is absorbed emits a fluorescing photon that is detected. The total detected photons N m are related to the laser intensity I as in the following formula: N m = Ω mi nε F f m V m e nεx, (5) 4πhν where Ω m is the spacial angle in figure 4, F is the probability that fluorescence photon is emitted when a laser photon is absorbed, f m = QT h slit h pixel with the quantumefficiency Q, temperature T, slit and ccd pixel height respectively h slit and h pixel, and V m = f A6 f A1 d slit where d slit is the width of the slit and f L is the focal distance of lens L. [1] Gathering the energy-related variables results in: n m (λ) hν dλ = F Ω m I nεt d slit r 2 h pixel f A6 laser e nεx, (6) Q h slit f A1 λ with n m (λ) the measured counts at each wavelength.

4 Results 8 4 Results 4.1 Calibration The dark current is measured with different measurement intervals, which is plotted in figure 5. Fitting results in N e = (.24 ±.8) + (7.7 ±.6)t (see formula 2). A sample spectrum is shown in appendix B. 2 Background measurement with different integration times 1.8 1.6 Average counts 1.4 1.2 1.8.6.4.2 5 1 15 2 Integration time [ms] Figure 5: Dark current measurement, the average is taken over the measured spectrum. The measured spectrum of Ne can be found in appendix A. Spectral lines are matched with literature values [1] in in figure 6. A second order polynomial fit gives the relation λ = (463.4 ±.2) + (.1891 ±.5) Ch + (6.2 ±.2) 1 6 Ch 2 nm. 76 Spectrograph calibration with Ne 74 72 Wavelength [nm] 7 68 66 64 62 6 58 6 7 8 9 1 11 12 13 14 15 16 Channel Figure 6: Calibration of the spectrograph using a neon lamp.

4 Results 9 4.2 Absorbtion, transmission and LIF The absorbtion, transmission and LIF spectrum of rhodamine 6G can be seen in figure 7. 6 5 Absorbtion, transmission and fluorescence of rhodamine 6G Absorbtion Transmission Fluorescence 4 3 2 1 HeNe laser 543.5 nm -1 45 5 55 6 65 7 75 8 85 Wavelength [nm] Figure 7: Absorbtion, transmission and LIF spectrum of rhodamine 6G. The cuvet was translated perpendicular to the laser-beam. The spectra at different positions can be found in figure 8. Counts 35 3 25 2 15 1 5 Rhodamine 6G fluorescence with translation perpendicular to laser-beam 1.2mm 2.4mm 3.6mm 4.8mm 6.mm 7.2mm 8.4mm 9.6mm Counts 35 3 25 2 15 1 5 Translation vs. counts at 543 nm 2 4 6 8 1 Position [mm] 5 55 6 65 7 75 8 85 Wavelength [nm] Figure 8: Spectra at different cuvet positions.

4 Results 1 Also LIF was measured using a green (543.5 nm) and yellow (594.1 nm) laser beam. Both spectra are plotted in figure 9. 4 35 LIF of rhodamine 6G with a yellow and a green laser Green 543.5 nm Yellow 591.4 nm 3 25 Counts 2 15 1 5 45 5 55 6 65 7 75 8 85 543.5 594.1 Wavelength [nm] Figure 9: Rhodamine 6G spectrum with a green and yellow HeNe laser. spectrum was measured using a higher filter. The yellow The measurement on photosynthesis of a leave can be seen in figure 1. The spectrum is measured for different times between turning on the laser and reading out the CCD. Counts 2 18 16 14 12 1 8 6 4 2 LIF leave measurements with different laser exposure times 6s 12s 18s 24s 3s 36s 42s 5 55 6 65 7 75 8 85 9 95 Wavelength [nm] Figure 1: LIF measurement on a green leave. The number of seconds in the legend is the time between turning on the laser and reading out the CCD.

5 Discussion 11 5 Discussion 5.1 Calibration The dark current of the CCD was measured 7.7 ±.6 electrons/s. This is clearly not consistent with the CCD specification, 218 e /pixels/s. Also N read = 122 electrons according to the CCD documentation, but it is.24±.8 according to the measurements. Looking at figure 13 in appendix B it is striking that there is a quite a number of negative counts. This could be caused by a background correction of the measurement software (it should obviously be turned off during this measurement), rendering the dark current measurements useless. The resolution of the spectrograph can be read from figure 12 in appendix A. The average resolution (FWHM) of the shown lines is.85 ±.2 nm. Using formula 3 combined with formula 4 to compute a cos θ results in the theoretical value λ.54 nm. The measured resolution is bigger than the computed value. This can be caused by additional errors introduced by cables and other equipment. 5.2 Absorbtion, transmission and LIF Looking at figure 7 one can see that when absorbtion is high, transmission is low and vice versa. This is of course what is to be expected. The fluorescence peak is around 57 nm, which is yellow/orange light. That is in agreement with observations of the eye: it looks orange. When closely looking at the fluorescence around 545 nm, one can see that there is fluorescence of wavelengths below the excitation (laser) wavelength, i.e. with a higher energy than the excitation energy. This is possible because electrons have thermal energy. The spectrum with the yellow laser in figure 9 shows a peak at the laser wavelength, while the spectrum with the green doesn t. This is because the absorbtion of the green 543.5 nm laser is very low, while the absorbtion of the yellow 594.1 nm laser isn t (see figure 7). The shape of both spectra are very much the same; the yellow spectrum looks weaker, but that s because a filter was used to be able to measure it correctly. But one can see that the yellow spectrum is moved to the right with respect to the spectrum of the green laser. This is because the yellow laser-beam has a lower energy. To compute the concentration of the rhodamine 6G solution, the inset of figure 8 was made with the relation of the counts at λ = 543 nm and the distance, which should obey equation 1. The fit results in nε = (1.55 ±.7) 1 3 m 1. With the known extinction coefficient of ε = 1.1 1 5 l mol 1 cm 1 this results in n =.141 ±.5 mmol l 1. In figure 8 the left side of the peak crawls to the right as the distance increases. This is because the fluorescing photons have to travel longer through the rhodamine 6G dye and there is more chance to collide. Especially higher energy photons have more chance to be absorbed (see figure 7). The fluorescence efficiency is computed using formula 6: n m(λ)hν λ Q dλ = F 1.43 1 5. The lhs for a LIF measurement with the green laser has been computed at 2.497 1 6, so F =.17. This seems a bit low for a dye that optimally has an F 1, but the whole computation is far from precise.

5 Discussion 12 The fluorescence spectrum of the green leave (figure 1) is divided into two parts: the curve at the center (65 75 nm) which decays as the times increases, and some peaks (55 575, 79, and 854 nm) which are more or less constant. The decaying curve in the center is due to photoinhibition. The brown color of the spot that was lit by the laser after a measurement also indicates that oxydation has taken place. The spikes don t change as time increases, so these are probabely reactions either not part of photosynthesis or where fluorescence takes place before electron transport.

6 Conclusions 13 6 Conclusions The dark current was measured 7.7±.6 electrons/s. The deviation from the specification of 218 electrons/s is caused by a measuring mistake. The resolution of the spectrograph was measured.85 ±.2 nm, whereas the theoretical value is λ.54 nm. The additional error is caused by other measurement equipment. The fluorescence of rhodamine 6G has a peak wavelength of 57 nm, which corresponds to the orange color of the solution. Excitation with a yellow laser shows a peak at the laser wavelength that doesn t occur when using a green laser. This agrees with the high absorbtion in green and low in yellow. The concentration of the rhodamine 6G solution was n =.141 ±.5 mmol l 1. The fluorescence efficiency is computed F =.17, while F 1 is expected. LIF on a green leave shows that photoinhibition occurs, but not all processes which procude fluorescence are effected by it. References [1] Handleiding Natuurkunde Praktikum N 4/5 (3B63), Technische Universiteit Eindhoven, faculteit Natuurkunde, september 2. [2] Introduction to Optics, second edition, Frank L. Pedrotti and Leno S. Pedrotti, Prentice-Hall, ISBN -13-16973-, Chapter 17. [3] An Introduction to Photosynthesis and Its Applications, Wim Vermaas, Arizona State University, http://photoscience.la.asu.edu/photosyn/education/photointro.html. [4] Biophysics 354, Biological Energy Conversion, Antony Crofts, University of Urbana- Champaign, http://www.life.uiuc.edu/crofts/bioph354/, Lecture 2, 21.

A Measured spectrum of Ne 14 A Measured spectrum of Ne Measured spectrum of Ne 4 35 3 25 Counts 2 15 1 5 5 1 15 2 25 CCD Channel Figure 11: Measurement of the spectrum of neon. 18 Partial spectrum of Ne (zoomed) 16 14 12 Counts 1 8 6 4 2 65 61 615 62 625 63 635 64 645 (Channel 749) (Channel 96) Wavelength [nm] Figure 12: Zoomed in on Ne spectrum.

B Background measurement spectrum 15 B Background measurement spectrum 7 6 Background measurement spectrum Integration time = 5ms 5 4 3 Counts 2 1-1 -2-3 -4 45 5 55 6 65 7 75 8 85 Wavelength [nm] Figure 13: A spectrum of a background measurement.