Inside the Black Box of an Environmental Testing Laboratory Basic Analytical Procedures

Similar documents
EPA's Revision to the 40 CFR Part 136 Method Detection Limit (MDL) Procedure

ANALYTICAL REPORT. Attn: Richard Boelter

ANALYTICAL REPORT. Attn: Richard Boelter

ANALYTICAL REPORT. Attn: Richard Boelter

ANALYTICAL REPORT. Attn: Richard Boelter

ANALYTICAL REPORT. Attn: Richard Boelter

METHOD 3600B CLEANUP

METHOD 3600C CLEANUP

Gas Chromatography Mass Spectrometry (GCMS)

OBJECTIVE DATA PACKAGE DELIVERABLES

Basic Digestion Principles

Copyright ENCO Laboratories, Inc. II. Quality Control. A. Introduction

Verification of LOD and LOQ according to the NELAC and TNI Standards

Evaluation of Several Columns and Solvents for Post-Extraction Gel Permeation Chromatography (GPC) Clean-up of Fish Tissue Prior to PCB Analysis

KESTREL. April 26, Mr. Stephen Evans Maine Yankee 321 Old Ferry Road Wiscasset, Maine 04578

METHOD 3510B SEPARATORY FUNNEL LIQUID-LIQUID EXTRACTION

Polycyclic Aromatic Hydrocarbons in Water by GC/MS PBM

METHOD 3665 SULFURIC ACID/PERMANGANATE CLEANUP

The Practicality (Necessity) of Use of Clean-up Techniques for the Analysis of D/F and PCB Congeners

ACZ Laboratories, Inc Downhill Drive Steamboat Springs, CO (800)

Microscale Solvent Extraction (MSE)

What type of samples are common? Time spent on different operations during LC analyses. Number of samples? Aims. Sources of error. Sample preparation

Analytical Method Name Preservative Container Water and Wastewater. Inorganics SM203 Corrosivity <4C 1L Plastic 1

METHOD 3520C CONTINUOUS LIQUID-LIQUID EXTRACTION

Some analyses have been subcontracted outside of the Pace Network. The subcontracted laboratory report has been attached.

Extraction of Water Samples by Separatory Funnel

Explosives by HPLC, LC/MS and LC/MS/MS

Revision: 11 (MBAS) ALLOWAY METHOD OUTLINE. Standard Laboratory Method:

Schedule. Draft Section of Lab Report Monday 6pm (Jan 27) Summary of Paper 2 Monday 2pm (Feb 3)

Shaker Table Extraction

Review and Reporting of Chemical of Concern (COC) Concentration Data Under the TRRP Rule (30 TAC 350)

STANDARD OPERATING PROCEDURES SOP: 1828 PAGE: 1 of 14 REV: 0.0 DATE: 05/12/95 ANALYSIS OF METHYL PARATHION IN CARPET SAMPLES BY GC/MS

Laboratory Analytical Data

Introduction. The following definitions may help you better understand the components of the data report.

METHOD 3520B CONTINUOUS LIQUID-LIQUID EXTRACTION

An Update on SW-846. Office of Resource Conservation and Recovery (ORCR)

Laboratory 101: A Guide to Understanding your Testing Laboratory

ANALYTICAL REPORT. Results relate only to the items tested and the sample(s) as received by the laboratory. Page 1 of 5

SYNOPSIS OF CHANGES TO BC LABORATORY MANUAL, MARCH 2017

Chemistry 311: Instrumental Analysis Topic 4: Basic Chromatography. Chemistry 311: Instrumental Analysis Topic 4: Basic Chromatography

Jo Marie Cook Bureau of Chemical Residue Laboratories

Appendix: Laboratory Testing Methods

Putting the Pieces of the Puzzle Together. By Kim Kirkland, Methods Team Leader EPA s Office of Resource Conservation and Recovery

CCME Reference Method for the Canada-Wide Standard for Petroleum Hydrocarbons (PHC) in Soil - Tier 1 Method

Method 8270C PAH. FD- Field Duplicate Samples

HPLC Winter Webinars Part 2: Sample Preparation for HPLC

Thin Film on Silicon Resistor Networks Models 2NBS, 2QSP Mold Material Change

Maine DEP DRO. MY05TP220A(0-0.5) MY05TP222A(0-0.5) FD MY05TP223A(0-0.5) FD MY05TP220A (EB) EB-Equipment Rinsate Blank FD- Field Duplicate Samples

Test Method: CPSC-CH-E

December 30, Laboratory Report This Page is to be Stamped Introduction: This report package contains total of 5 pages divided into 3 sections:

APPENDIX II REQUIRED CONTAINERS, PRESERVATION TECHNIQUES, AND HOLDING TIMES FOR SOLID WASTE AND WASTEWATER

Ground Water & UST Samples: Containers, Preservation and Hold Times Table

Perfluorinated Alkyl Acids (PFAA) in Water by LC/MS/MS - PBM

TEST REPORT. : Lead Frame / Ag is plated on Ni-Fe Alloy-A42 material

Preparation of Food and Feed Samples for Metals Analysis

Care and Use Manual for Supelco Multi-Layer Silica Gel Column and Dual-Layer Carbon Reversible Column

LCTech GmbH Chromatographie

APPENDIX A TO PART 136 METHODS FOR ORGANIC CHEMICAL ANALYSIS OF MUNICIPAL AND INDUSTRIAL WASTEWATER METHOD 609 NITROAROMATICS AND ISOPHORONE

SeCtiOn 5 [STOCK AND CUSTOM] Assurance. Multi-Element CLP Standards

Pure Chromatography Consumables Pure flexibility. Pure specialization. Pure convenience.

STANDARD OPERATING PROCEDURES

TNI V1M Standard Update Guidance on Detection and Quantitation

Appendix A. Glossary of Definitions, Acronyms, Abbreviations and Symbols. March 1997

Key Considerations for Ensuring Quality Radioanalytical Laboratory Services for Superfund Sites Activities

TEST REPORT. Page : 1 of 9 Report No. RT14R-U E Date: Oct. 13, : The following submitted sample(s) said to be:-

Better Site Characterization through Incremental Sampling Methodology Mark Bruce Ph. D.

CORUS R, D and T, Swinden Technology Centre, Rotherham, UK S60 3AR. HALL ANALYTICAL LABORATORIES, Manchester, UK M23 9YJ

Sample Submittal Form

DOE S RADIOLOGICAL TRACEABILITY PROGRAM FOR RADIOANALYTICAL MEASUREMENTS: WORK IN PROGRESS

KSA Environmental Laboratory Inc.

TETRA TECH, INC. December 8, Lynn Nakashima Berkeley Regional Office 700 Heinz Avenue, Suite 200C Berkeley, California 94710

Application of Selenium Speciation Analysis to Elucidate Limitations with Accepted Total Selenium Methods

ALLOWAY METHOD OUTLINE

This project has been funded with support from the European Commission. This publication reflects the views only of the authors, and the Commission

TEST REPORT. Address : , Doksan-dong, Geumcheon-gu, Seoul, Korea Page: 1 of 12 Report No. RT16R-S E Date: Jul.

Use this checklist to properly pack your GEL sample cooler

GENERAL. Bottle Type (Mimimum required) Water/ WW Methods. Label Color SW84 6. Parameter. Holding Time. Preservative

Sampling, Storage and Pre-Treatment Techniques

ANALYTICAL REPORT. Attn: Thomas W Hensel

METHOD 8082A. POLYCHLORINATED BIPHENYLS (PCBs) BY GAS CHROMATOGRAPHY

DEPARTMENT OF ENVIRONMENTAL PROTECTION Laboratory Accreditation Program

USEPA CONTRACT LABORATORY PROGRAM NATIONAL FUNCTIONAL GUIDELINES FOR ORGANIC DATA REVIEW

PREPARE YOUR SAMPLE:

State of the art of mercury speciation analysis

Lab 6 Guide: Extraction (Sept 29 Oct 5)

6 PREPARING THE SAMPLING AND ANALYSIS PLAN (SAP)

The Analysis of Dioxins and Dioxin-Like Compounds

Level. Automate your processes Automate your lab Innovate with. sensing. EasyPREP. sample handler. Automated Sample Preparation.

METHOD 7060A ARSENIC (ATOMIC ABSORPTION, FURNACE TECHNIQUE)

INTRODUCTION. Scope and Applicability

APPENDIX A TO PART 136 METHODS FOR ORGANIC CHEMICAL ANALYSIS OF MUNICIPAL AND INDUSTRIAL WASTEWATER METHOD 610 POLYNUCLEAR AROMATIC HYDROCARBONS

Organic analyte procedures are characterized

ANALYTICAL REPORT. Job Number: Job Description: TO4-2012, RACER, GM Wilmington

TEST REPORT. : The following submitted sample(s) said to be:- SAMPLE RECEIVED : Jan. 07, 2019 TESTING DATE : Jan. 07, 2019 ~ Jan.

METHOD 8100 POLYNUCLEAR AROMATIC HYDROCARBONS

separation of the cleaned extract in subgroups of compounds (PCDDs, PCDFs, PCBs) depending on their polarity and geometry. The fractions can then be a

Ensure reproducible Polymeric SPE workflow for high-throughput bioanalysis applications

Verification and Review of Data for Chlorinated Dioxins, Furans and PCB Congeners by Isotope Dilution HRGC/ HRMS

QUALITY ASSURANCE PROJECT PLAN PHASE I EMORY RIVER DREDGING TENNESSEE VALLEY AUTHORITY KINGSTON FOSSIL PLANT ASH RECOVERY PROJECT

Transcription:

Ask The Expert Webinar Series Inside the Black Box of an Environmental Testing Laboratory Basic Analytical Procedures Karla Buechler Corporate Technical Director

Outline of Environmental Analysis Part 1 The Black Box Laboratory functions. What items should be considered during the method selection process? Overview of methodology including advantages and disadvantages. Part 2 When and what should I communicate to the lab? What does the lab need from me? What do I need from the lab? 2

Part 1 - Project Definition Why must I do the testing? DDT What decision do I need to make? What are my method selection considerations? 3

Part 2 - Method Selection Considerations Project Needs and Method Selection Regulatory Programs Detection Levels Project Objectives Levels of certainty Previous Analytical Activities Subsequent Analytical Activities Costs 4

Part 2 - Continue Method Selection Criteria Laboratory Capabilities and Method Selection Sensitivity - Method Detection Levels Selectivity (identification) Laboratory method offerings Laboratory Certifications Precision and Accuracy Reproducibility Reporting Capabilities Costs/value additions 5

DDT Method Comparison 8081 vs 8270 vs 1699 8081 8270 1699 Selectivity Sensitivity Cost 6

Perchlorate Method Comparison 314 vs 331 vs 6850 3 2.5 2 1.5 1 314 331 6850 0.5 0 Selectivity Sensitivity Cost 7

Arsenic Method Comp 6010 vs 6020 vs 6020 collision cell 4 3.5 3 2.5 2 6010 6020 6020 w/cell 1.5 1 0.5 0 Selectivity Sensitivity Cost 8

Part 1 - Project Initiation Involve the lab immediately. What methods do you need? What type of samples? What type of containers? What analytes at what sensitivity? 9

Part 1 - Communication and Documentation Quotation SOW SAP QAPP Project kick off call COC Bottle orders Sample confirmation 10

Part 1 Who Makes up the Black Box? General and Administrative Functions Management and Business Quality Assurance Project Management & Customer Service Sales and Marketing Field Services Sample Receipt and Login Report Production 11

Part 1 - What Makes up the Black Box? Technical and Analytical Functions Organic Sample Prep Metals Sample Prep Classical Chemistry Metals Analyses GC Organics Analyses GCMS Analyses Specialty Analyses (Rad, Micro, Geotech, Dioxin, PFAS, etc..) 12

Part 1 Organic Methods Performed in the Black Box 1. Sample collection and shipment to the lab. 2. Sample pre-extraction steps. 4. Sample extract Concentration. 5. Sample analysis 3. Sample extraction and clean up. 6. Process and review data. Assess QC elements, narrate anomalies. Send report to client. 13

Part 1 Sample Collection Field quality control samples Bottles, preservatives & holding times Chain of custody (CoC) Packing a cooler Sample acceptance at the laboratory Sample acknowledgements Let the analysis/fun begin!!! 14

Part 1 - Sample Pre-extraction Steps Goal - We need a small representative sample of a larger sample. Homogenization Subsampling Drying Grinding Sieving 15

Part 1 - Organic Sample Extraction Methods Goal To selectively remove the target analytes from other interfering components in the sample. Liquid/liquid separatory funnel extraction (Aq) Solid phase extraction (SPE) (Aq) Sonication (Solid) Soxhlet (Solid) 16

Part 1 - Organic Sample Cleanups Goal To further isolate our target analytes from the sample matrix interferences. Gel Permeation Chromatography (GPC) Solid Phase Extraction (SPE) including silica, florisil, C18 Sulfuric Acid Mercury 17

Part 1 - Organic Sample Concentration Goal To increase the sensitivity of the method by decreasing the extract final volume. Kuderna Danish (Kd) Rotary evaporators (RotoVap) TurboVap/RapidVap 18

Organic Instrumentation Inst. Pros Cons GC Cost effective, rugged, flexible, sensitive Interferences, selectivity, need site history GCMS Selectivity, flexible, long analyte list, identification Cost, sensitivity, expertise needed HPLC Same as GC Same as GC LCMS Same as GCMS Same as GCMS 19

How Does a GC Work? 20

How Does a GC/MS Work? e - e - e - e - e - e - e - e - e - e - e - Source of electrons 21

Part 1 - Organic Analytical Methods Pesticides including DDT (Method 8081, 8270, and 1699) Perchlorate (314.0, 314.1, 8321, 6850, 6860, 331) PCBs, Herbicides, Volatiles, Hydrocarbons, PAHs, PFAS (PFOA and PFOS), Dioxins, etc. 22

Part 1 Method Selected for DDT by Method SW846-8081A 1. Aqueous samples are collected in glass and shipped chilled to the lab. 2. Sample pre-extraction steps. Consult client if ½ inch of sediment present. 3. Sep funnel extraction with 3X60 mls of DCM. Routine cleanups include Florisil and Sulfur. 4. Concentrate the extract using Kuderna-Danish followed by N-evap. 5. Sample analysis by GC/ECD with dual column confirmation. 6. Process and review data. Assess QC elements, narrate anomalies. Send report to client. 23

Part 1 - Additional Analyses Goal Get useful data the first time. Re-extractions Re-injections Dilutions Confirmations QC failures 24

Part 1 Inorganic Methods Performed in the Black Box 1. Same 2. Same 3. Sample extraction (no cleanups) 4. No sample extract concentration. 5. Same 6. Same 25

Part 1 - Inorganic Sample Preparation Goal To break down the sample matrix while leaving the elements of interest in tact and in solution. Acid Digestion Microwave Digestion Distillation Leaching procedures 26

Part 1 - Inorganic Instrumentation Instrument Advantages Disadvantages ICP ICPMS ICPMS (w/collision cell) Speed, cost effective, automation, identification, higher concentration ranges, broader range of matrix types historically Increased selectivity and sensitivity, As interference Increased selectivity and increased sensitivity for all matrices, no As interference Sensitivity, spectral interferences Intended for trace analyses Intended for trace analyses 27

Part 1 - Inorganic Analytical Methods Method 6010/EPA 200.7 Method 6020/EPA 200.8 Method 6020 with collision cell 7470A for Mercury 7196A for Hex Chrom 9040B for Alkalinity And many many more 28

Part 1 Method Selected for (Aq) Arsenic by Method SW-846 6020A 1. Sample collection in nitric acid preserved plastic or glass. 2. Sample pre-extraction steps. Mix by shaking and pour aliquot immediately 4. Sample extract Concentration. None 3. Digest the sample by adding HNO3 and HCL. Heat to reduce volume to 20 ml. 5. Sample analysis by ICP/MS. 6. Process and review data. Assess QC elements, narrate anomalies. Send report to client. 29

Part 2 Client Laboratory Communication Exchange Phase 1 You tell us what you need. We tell you what we can do. Phase 2 We tell you what we did and explain why in the case narrative. Phase 3 You tell us if we met your needs. 30

Part 2 - How do I get a price quotation? Contact your CRM team. Contact your PM. Contact your AE Submit a request on our website Call (866) 785-LABS (5227) 31

Part 2 - Why does TAT change? Project creep Sample matrix related concerns Positive target analyte levels Laboratory QC outside limits Instrument maintenance 32

Part 2 - The Case Narrative Sample condition upon receipt Chain of Custody (CoC) discrepancies Unusual sample preparation issues Unusual sample analysis issues Depends on regulatory program If you want to see something ask for it 33

Part 2 - The Final Deliverables You will get a report. You will get a case narrative. You will get an EDD. You get to give us feedback You will get an invoice. 34

Ask The Expert Webinar Series Thank you for attending Inside the Black Box of an Environmental Testing Laboratory Basic Analytical Procedures To submit a question, type it into the Questions panel in the GoToWebinar toolbar and click Send. If you have any additional questions for today s presenter you may submit them directly to: http://testamericainc.com/services-we-offer/ask-the-expert/karla-buechler/ Please be sure to visit the Ask the Expert Webinar Series web page for other scheduled webinars at: www.testamericainc.com/services/webinar_series To view a recording of this webinar session, please contact: info@testamericawebinars.com Copyright 2018, TestAmerica. All rights reserved.