PAGE : 1 of INOAC CORPORATION AICHI, JAPAN 446-804. The following merchandise was (were) submitted and identified by the client as: Sample Receiving : 18/02/2016 Testing Date : 18/02/2016 to 14/03/2016 : Please see the next page PLO 81, Jalan MIEL 2, Kawasan MIEL Pasir Gudang Fasa 4, 81700 Pasir Gudang, Johor, Malaysia t +6(07) 211 684 f +6(07) 224 31 www.sgs.com
PAGE : 2 of AICHI, JAPAN 446-804. Test Item (s) : Unit Method MDL Result Limit Chromium VI (Cr6+) IEC 62321 : 2008 Annex C 2 1000 Cadmium (Cd) IEC 62321- : 2013 2 100 Mercury (Hg) IEC 62321-4 : 2013 2 1000 Lead (Pb) IEC 62321- : 2013 2 1000 NOTE: (a) = Not detected (<MDL) (b) = mg/kg (c) MDL= Method Detection Limit PLO 81, Jalan MIEL 2, Kawasan MIEL Pasir Gudang Fasa 4, 81700 Pasir Gudang, Johor, Malaysia t +6(07) 211 684 f +6(07) 224 31 www.sgs.com
PAGE : 3 of AICHI, JAPAN 446-804. Test Item (s) : Unit Method MDL Result Limit PBBs (Polybrominated Biphenyls) Monobromo Biphenyl Dibromo Biphenyl Tribromo Biphenyl Tetrabromo Biphenyl Pentabromo Biphenyl Hexabromo Biphenyl Heptabromo Biphenyl Octabromo Biphenyl Nonabromo Biphenyl Decabromo Biphenyl PBDEs (Polybrominated Diphenyl ethers) GCMS as per IEC 62321-6 : 201 GCMS as per IEC 62321-6 : 201 GCMS as per IEC 62321-6 : 201 GCMS as per IEC 62321-6 : 201 GCMS as per IEC 62321-6 : 201 GCMS as per IEC 62321-6 : 201 GCMS as per IEC 62321-6 : 201 GCMS as per IEC 62321-6 : 201 GCMS as per IEC 62321-6 : 201 GCMS as per IEC 62321-6 : 201 1000 Monobromo Diphenyl Ether Dibromo Diphenyl Ether Tribromo Diphenyl Ether Tetrabromo Diphenyl Ether Pentabromo Diphenyl Ether Hexabromo Diphenyl Ether Heptabromo Diphenyl Ether Octabromo Diphenyl Ether Nonabromo Diphenyl Ether Decabromo Diphenyl Ether NOTE: (a) = Not detected (<MDL) (b) = mg/kg (c) MDL= Method Detection Limit GCMS as per IEC 62321-6 : 201 GCMS as per IEC 62321-6 : 201 GCMS as per IEC 62321-6 : 201 GCMS as per IEC 62321-6 : 201 GCMS as per IEC 62321-6 : 201 GCMS as per IEC 62321-6 : 201 GCMS as per IEC 62321-6 : 201 GCMS as per IEC 62321-6 : 201 GCMS as per IEC 62321-6 : 201 GCMS as per IEC 62321-6 : 201 1000 PLO 81, Jalan MIEL 2, Kawasan MIEL Pasir Gudang Fasa 4, 81700 Pasir Gudang, Johor, Malaysia t +6(07) 211 684 f +6(07) 224 31 www.sgs.com
PAGE : 4 of AICHI, JAPAN 446-804. INOAC CORPORATION CRSPG/00478/16 PLO 81, Jalan MIEL 2, Kawasan MIEL Pasir Gudang Fasa 4, 81700 Pasir Gudang, Johor, Malaysia t +6(07) 211 684 f +6(07) 224 31 www.sgs.com
1. DETERMINATION OF CADMIUM CONTENT BY IEC 62321-2013 Weight sample (0.2-0.g) into digestion vessel 3. DETERMINATION OF MERCURY CONTENT BY IEC 62321-4 2013 Weight sample (0.1-0.g) into digestion vessel PAGE : of 2. DETERMINATION OF LEAD CONTENT BY IEC 62321-2013 Weight sample (0.2-0.g) into digestion vessel 4. DETERMINATION OF HEXAVALENT CHROMIUM BY IEC 62321 2008 Sample Preparation Add colour-developing reagent Acidify with H 2SO 4 Let stand for -10 min Analyses by UV- Spectrophotometer (40 nm). DETERMINATION OF PBB/PBDE WITH GC-MS BY IEC 62321-6 201 Weight sample (0.-4.0g) into extraction thimble Soxhlet Extraction with Toluene Filter through 0.4 um membrane filter Analyses by GC-MS (with appropriate dilution) PLO 81, Jalan MIEL 2, Kawasan MIEL Pasir Gudang Fasa 4, 81700 Pasir Gudang, Johor, Malaysia t +6(07) 211 684 f +6(07) 224 31 www.sgs.com