[application note] INTRODUCTION EXPERIMENTAL. Specimens. Extraction

Similar documents
DETERMINATION OF OCs, PCBs AND SYNTHETIC PYRETHROIDS IN ANIMAL FAT

Analysis of Serum 17-Hydroxyprogesterone, Androstenedione, and Cortisol by UPLC-MS/MS for Clinical Research

The Use of Tandem Quadrupole GC/MS/MS for the Determination of Polycyclic Aromatics Hydrocarbons (PAHs) in Food Products

Benzoylecgonine in Urine by SAMHSA GC/MS

Determination of Cannabinoids (THC) in Biological Samples

Application Note. Gas Chromatography/Mass Spectrometry/Food Safety. Abstract. Authors

The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION

Opiates in Urine by SAMHSA GC/MS

Confirmation and Quantitation of THC in Oral Fluid Using an MRM Method on a GC-Triple Quadrupole MS

ApplicationNOTE A STUDY OF THE ANALYSIS OF POLYBROMINATED DIPHENYL ETHER FLAME RETARDANTS BY GC/MS/MS. Introduction. Materials and Methods

A Rapid Approach to the Confirmation of Drug Metabolites in Preclinical and Clinical Bioanalysis Studies

Sensitive and Repeatable Analysis of Pesticides in QuEChERS Extracts with APGC-MS/MS

Identification and Quantitation of PCB Aroclor Mixtures in a Single Run Using the Agilent 7000B Triple Quadrupole GC/MS

T H E ANA LYSIS O F DIOX INS AND F U R A NS USING H RG C- H IG H R E SO LU T IO N MS W IT H T H E AU T OS P EC- ULTIMA NT

Rapid, Robust, and Sensitive Detection of 11-nor-D 9 - Tetrahydrocannabinol-9-Carboxylic Acid in Hair

WADA Technical Document TD2003IDCR

A S ENSIT IV E M E T HO D FO R T H E D E T E RM INAT IO N O F ENDO C RIN E- D IS RU P T ING COM P OUNDS IN RIV E R WAT E R BY L C / MS/MS

Determination of N-Nitrosamines by USEPA Method 521 using Triple Quadrupole Gas Chromatography Mass Spectrometry

Improved Extraction of THC and its Metabolites from Oral Fluid Using Oasis PRiME HLB Solid Phase Extraction (SPE) and a UPLC CORTECS C 18

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

Jonathan P. Danaceau, Erin E. Chambers, and Kenneth J. Fountain Waters Corporation, Milford, MA USA APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS

Highly Sensitive and Rugged GC/MS/MS Tool

Analysis of Biomarkers in Crude Oil Using the Agilent 7200 GC/Q-TOF

Toxicity, Teratogenic and Estrogenic Effects of Bisphenol A and its Alternative. Replacements Bisphenol S, Bisphenol F and Bisphenol AF in Zebrafish.

Analysis of Opioids Using Isotope Dilution with GCMS-TQ8030 GC/MS/MS. No. GCMS No. SSI-GCMS-1401

METHADONE and EDDP in urine by GC-MS Code GC Method of Confirmation by GC-MS

University of the Aegean

ApplicationNOTE Abstract

Supporting Information

Determination of releasable 2,4,6-trichloroanisole in wine by cork stoppers (Resolution OIV-Oeno 296/2009)

Sensitive Detection of 2-MIB and Geosmin in Drinking Water

DETERMINATION OF GAMMA-HYDROXYBUTYRATE (GHB) BY HEADSPACE-GC/MS (FID) IN FORENSIC SAMPLES

Simultaneous Estimation of Residual Solvents (Isopropyl Alcohol and Dichloromethane) in Dosage Form by GC-HS-FID

A Workflow Approach for the Identification and Structural Elucidation of Impurities of Quetiapine Hemifumarate Drug Substance

Quantitation of High Resolution MS Data Using UNIFI: Acquiring and Processing Full Scan or Tof-MRM (Targeted HRMS) Datasets for Quantitative Assays

VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION

Amphetamines, Phentermine, and Designer Stimulant Quantitation Using an Agilent 6430 LC/MS/MS

DETERMINATION OF PESTICIDES IN FOOD USING UPLC WITH POLARITY SWITCHING TANDEM QUADRUPOLE LC/MS/MS

FORMIC ACID in URINE by GC/MS-headspace - Code GC74010

Analysis of Drugs in Hair using GC/GC/MS CAT Meeting 3/2/07

ENVIRONMENTAL analysis

Investigating Source, Age, Maturity, and Alteration Characteristics of Oil Reservoirs Using APGC/MS/MS Analysis of Petroleum Biomarkers

Simplified Approaches to Impurity Identification using Accurate Mass UPLC/MS

Uncontrolled Copy. SOP 109 Ethylene Glycol Screen by Gas Chromatography/Mass Spectrometry. Table of Contents. 1. Principle of Assay...

STANDARD OPERATING PROCEDURES SOP: 1828 PAGE: 1 of 14 REV: 0.0 DATE: 05/12/95 ANALYSIS OF METHYL PARATHION IN CARPET SAMPLES BY GC/MS

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW

Method of confirmation by GC-MS

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

Quantitative analysis of mitragynine in human urine by high performance liquid chromatography-tandem mass spectrometry

Determination of 198 pesticide residues in eggplant using Gas Chromatography tandem Mass Spectrometry/Mass Spectrometry

GAFTI Analytical method for ISO/TS 16179:2012 Detection and Determination of Organotin Compounds in Footwear and Apparel Materials by GC-MS

A Case of Pesticide Poisoning: The Use of a Broad-Scope Tof Screening Approach in Wildlife Protection

DETERMINATION OF EPHEDRINE, PSEUDOEPHEDRINE, AND NOREPHEDRINE IN HUMAN URINE USING GC-MS OF THE METHYLBORONIC ACID DERIVATIVES

Determination of Elemental Sulfur in Explosives and. Explosive Residues by Gas Chromatography-Mass Spectrometry. Kimberly S.

Mass Spectral Studies of Polypropylene Chromatographic Well Plates

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

ApplicationNOTE THE ANALYSIS OF POLYCHLORINATED BIPHENYLS (PCBS) BY GC-HIGH RESOLUTION MASS SPECTROMETRY USING THE MICROMASS AUTOSPEC ULTIMA NT

Psychoactive Drugs Urine LC-MS/MS Analysis Kit User Manual

Method of determination of phtalates in spirituous beverages by gaschromatography/mass

Determination of 17 Organotin Compounds in Beverages Using Triple Quadrupole GC-MS/MS System

Trace analysis of mesityl oxide and diacetone alcohol in pharmaceuticals by capillary gas chromatography with flame ionization detection

LC/MS/MS qua ntitation of β-estradiol 17-acetate using an Agilent 6460 Triple Quadrupole LC/MS working in ESI negative ion mode

Place a collection tube beneath cartridge. 3 ml methylene chloride/isopropyl alcohol/ hydrochloric acid (60/40/1) Collect the eluant

Hints and Tips for APGC Coupled with Xevo TQ-S for Food and Environmental Analysis

Detection of Phencyclidine in Human Oral Fluid Using Solid Phase Extraction and Liquid Chromatography with Tandem Mass Spectrometric Detection

Applying the Technology of the TurboMatrix 650 ATD to the Analysis of Liquid Accelerants in Arson Investigation

OPTIMISATION OF SOLID PHASE MICROEXTRACTION (SPME) CONDITIONS FOR HEADSPACE ANALYSIS OF ORGANOPHOSPHATE PESTICIDES IN WHOLE BLOOD

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

Determination of Pharmaceuticals in Environmental Samples

Sensitive determination of THCCOOH in hair to regulatory requirements using Triple Quadrupole GC-MS/MS

Plasma Metanephrines and 3-Methoxytyramine by LC/MS/MS Using Agilent SimpliQ WCX SPE, 1290 Infi nity LC, and 6460 Triple Quadrupole LC/MS

ISSN: ; CODEN ECJHAO E-Journal of Chemistry , 7(2),

Fast Screening and Quantitation of Perfluorinated Sources from Textiles using Chemical Ionization GC-MS

Determination of Beta-Blockers in Urine Using Supercritical Fluid Chromatography and Mass Spectrometry

Residual Solvents in Pharmaceuticals by USP Chapter <467> Methodology

VMA, HVA, 5-HIAA Urine LC-MS/MS Analysis Kit User Manual

Quantification of Rice Aroma, 2-Acetyl-1-Pyrroline (2-AP), Using TurboMatrix Headspace Trap Coupled with GC/NPD and GC/MS

The Emergence of Benchtop Tandem Quadrupole Mass Spectrometers as a Routine Tool in Quantitative GC/MS/MS Applications

Characteristic of Calibration Curve Resulting from the Use of 2 H-analogs of the Analyte as Internal Standards--Methamphetamine Example

A Fast and Sensitive Method for Residual Hydrazine Analysis in Pharmaceutical Samples

New Dynamic MRM Mode Improves Data Quality and Triple Quad Quantification in Complex Analyses

Xinyu LIU, Peter JOZA, Andrew MASTERS, Bill RICKERT

Author. Abstract. Introduction

Test method for the determination of NDMA and NDEA by LC-MS/MS in Sartan containing film coated tablets

GC-CI-MS analysis of TMS derivatives

JWH-018 and JWH-022 as Combustion Products of AM2201

Determination of Organochlorine Pesticides and Polychlorinated Biphenyls Using GC/MS/MS Operated in the MRM Mode

Rapid method development to study plasma stability of diverse pharmaceutical compounds using Rapid Resolution LC and triple quadrupole MS

Applying MRM Spectrum Mode and Library Searching for Enhanced Reporting Confidence in Routine Pesticide Residue Analysis

ApplicationNOTE ULTRA TRACE ANALYSIS OF DIOXINS AND FURANS IN HUMAN ADIPOSE TISSUE USING SFE-LC EXTRACTION/CLEANUP AND THE WATERS AUTOSPEC ULTIMA NT

Limit-test of NDMA and NDEA in Sartans. by GC-MS (Liquid-direct-injection)

Application Note GCMS-03 Reliable high-throughput quantification of melamine and related analogs below regulatory limits in food using the EVOQ GC-TQ

Sulfotepp impurities in Chlorpyrifos EC formulations

DEVELOPMENT AND VALIDATION OF GC-FID METHOD FOR THE DETERMINATION OF ETHANOL RESIDUE IN MARJORAM OINTMENT

Analyzing Residual Solvents in Pharmaceutical Products Using GC Headspace with Valve-and-Loop Sampling

N-(1-carbamoyl-2-methyl-propyl)-1-(5-chloropentyl)indazole-3- carboxamide

The Analysis of Residual Solvents in Pharmaceutical Products Using GC-VUV and Static Headspace

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma

Transcription:

Testing for GHB in hair by GC tandem quadrupole MS Marie Bresson, Vincent Cirimele, Pascal Kintz, Marion Villain; Laboratoire Chemtox, Illkirch, France Timothy Jenkins, Waters Corporation, Manchester, UK Jean-Marc Joumier, Waters Corporations, St. Quentin en Yvelines, France INTRODUCTION Gamma hydroxybutyric acid (GHB) is a substance naturally present within mammal species (Figure 1). Figure 1. Structure of GHB. GHB has been used clinically since 1960s as an intravenous anesthetic in the treatment of insomnia, alcohol, and opiate withdrawal syndrome and in cerebrovascular disorders. 1 More recently, the molecule has been misued from its intended therapeutic use by bodybuilders to increase muscle mass; by ravers because it produces euphoria and can balance some side-effects of the drug ecstasy; and by rapists in cases of sexual assault. 2 GHB is detected in blood or urine within 6 to 12 hours of being administered. Hair analysis allows an increase in the detection window depending on the hair length, with 1 cm corresponding approximately to one month growth. Recently, hair analysis was used to prove a single exposure. For GHB, hair allows analysts to detect the difference between endogenous production and single exposure in sexual assault for example. 3 A sensitive, specific, and reproducible method has been developed to detect and quantify GHB in hair by gas chromatography and tandem quadrupole mass spectrometry, GC/MS/MS. Figure 2. Waters Quattro micro GC/MS/MS System. EXPERIMENTAL Specimens Hair specimens from forensic cases are used to confirm or disprove a sexual assault under GHB. Specimens are stored at room temperature until analysis. Extraction The hair was decontaminated twice using 15 ml of dichloromethane, for 2 min at room temperature. The segmentation of hair is undertaken to differentiate a single exposure from an endogenous concentration of GHB. Each segment measures 3 mm. 5 to 10 mg of decontamined hair were incubated in 0.5 ml 0.01 NaOH in presence of 10 ng of GHB-d 6 used as internal standard overnight at 56 C. After cooling, the homogenate was neutralized with 60 µl 0.01 HCl, and 2 ml of ethyl acetate were added. After agitation (95 cycles/min for 15 min) and centrifugation, 15 min at 3000 rpm, the organic phase was removed and evaporated to dryness. The residue was derivatized by adding 35 µl BSTFA + 1% TMCS and incubated for 30 min at 70 C.

GC/MS/MS procedure The samples were analyzed on an Agilent 6890 GC coupled to Waters Quattro micro GC tandem quadrupole Mass Spectrometer operated in EI+ mode (Figure 2). Data were acquired and processed with Waters MassLynx Software. A 1 µl aliquot of extract was injected into the column of a Hewlett- Packard (Palo Alto, CA, U.S.) gas chromatograph (6890 Series). The flow of carrier gas (helium, purity grade 99.9996%) through the column (OV-1 capillary column, 100 % dimethylpolysiloxane, 30 m x 0.25 mm i.d, 0.25 µm film thickness) was 1 ml/min. The injector temperature was 270 C. Splitless injection was employed with a split valve off-time of 1.0 min. The column oven temperature was programmed to rise from an initial temperature of 70 C maintained for 1 min to 160 C at 15 C/min, and to 295 C at 40 C/min maintained for the final 2 min. The total run time was 12.38 min. The Quattro micro GC tandem quadrupole Mass Spectrometer was used in electron impact (EI+) mode. The ion source was operated at 180 C with an electron energy of 70 ev and a filament current of 200 µa. The acquisition mode was multiple reaction monitoring (MRM) at an argon collision gas pressure of 3.00 x 10-3 Bar. The electron multiplier was set at 650 V. GHB and GHB-d 6, their MRM transitions, collision energies, and retention times are listed in Table 1. One transition has been chosen to quantify the molecule and the others are used to identify the molecule. Method validation A standard calibration curve was obtained by adding 0.5 ng (0.1 ng/mg), 1 ng (0.2 ng/mg), 2.5 ng (0.5 ng/mg), 5 ng (1 ng/mg), 15 ng (3 ng/mg), 50 ng (10 ng/mg), and 75 ng (15 ng/mg) of GHB in 0.5 ml of NaOH. Intra-day and between-day precisions for GHB were determined using NaOH spiked with GHB at final concentration of 0.1 ng/mg (n=10). Relative extraction recovery was determined by comparing the representative peak of GHB extracted at the final concentration of 0.1 ng/mg with the peak area of a methanolic standard at the same concentration (n=3). The limit of detection (LOD) was evaluated by decreasing concentration of GHB until a response equivalent to three times the background noise was observed for the each transition. For the limit of quantification (LOQ) a response greater than 10 times the background noise is necessary. RESULTS AND DISCUSSION It is desirable to produce an intense signal that is characteristic for GHB. Selectivity and sensitivity are increased by almost suppressing the noise level. The parent ion of GHB (m/z 233.1 to 233.1 and 131.1) and GHB-d 6 (m/z 239.1 to 239.2) correspond to the molecular ion obtained after derivatization. The ion m/z 204.1 (to 162.1) for GHB was chosen based upon criteria of specificity and abundance (Figure 3). Molecule Retention time (min) Precursor Ion (m/z) Product Ion (m/z) Collision energy (ev) GHB-d 6 6.12 239.1 239.2 1 233.1 1 233.1 GHB 6.15 131.1 20 204.1 162.1 5 Table 1. GHB, GHB-d 6 and MRM method parameters. Quantification transition is underlined.

Figure 3. GHB, BSTFA derivatized, EI mass spectrum (70 ev). The calibration curve corresponds to the linear regression between the peak area ratio of GHB to I.S. and the final concentration of drug for a sample of 5 to 10 mg. Response of GHB was linear in the range 0.1 to 15 ng/mg, and the representative curve for the quantification transition of GHB is illustrated in Figure 4. The correlation coefficient was 0.9997. Figure 5. Chromatogram obtained after extraction of GHB at the final concentration at 0.1 ng/mg by the established procedure. Top: GHB-d 6 with its daughter ion at m/z 239.2. Middle: quantification transition m/z 233.1 to 233.11. Bottom: two qualifying transitions of GHB. Figure 4. Calibration curve for quantification transition of GHB. The within-batch precision was 9.63% for the quantification transition and the extraction recovery (n=3) was determined to be 49.05%. The limit of detection was 0.05 ng/mg and the limit of quantification was the first point of the calibration curve, that is, 0.1 ng/mg (Figure 5). The analysis of a 2.4 cm strand of hair, obtained from a forensic case, demonstrated the presence of GHB in each segment at the concentration of about 0.17 to 0.23 ng/mg (Figure 6). The chromatogram obtained after the analysis of the last segment is illustrated in Figure 7. This was considered a negative case. A positive case was illustrated in Figure 8. Figure 6. Hair segmentation from a forensic case.

of physiological GHB is relatively important. So, an analysis using segmentation will enable determination due to a single exposure (Figure 8). The quantification transition has been chosen according to the peak abundance for GHB. The two other transitions have been chosen based upon criteria of specificity and abundance. Figure 7. Chromatogram obtained after extraction by established procedure of a 9.0 mg hair of a person. GHB was quantified at the concentration of 0.20 ng/mg. Top: GHB-d 6 with its daughter ion at m/z 239.2. Middle: quantification transition m/z 233.1 to 233.11. Bottom: two qualifying transitions of GHB. GC/MS/MS appears to be a more useful method for GHB determination in hair than GC/MS. Actually, this method allows us to obtain greater sensitivity and specificity, which is important when trace amounts of analytes are tested. The comparison between MRM and SIR (selected ion recording) modes is shown in Figure 9. Figure 8. Hair segmentation from a positive forensic case for GHB. DISCUSSION Physiological concentrations of GHB were published by Kintz et al. 3 in hair obtained from 24 people. These concentrations were in the range 0.5 to 12 ng/mg. This concentration can be less important, as we have observed with the strand of analyzed hair (0.17 to 0.23 ng/mg). Everyone has GHB in their organism, and therefore in his or her hair. As a consequence, it is useless to perform assays with the whole strand of hair, considering that the range of concentrations Figure 9. Chromatograms obtained in SIR (top) and MRM (bottom) mode of detection after extraction of GHB by established procedure.

The GC/MS/MS detection in the MRM mode allows us to obtain better chromatograms which are cleaner (lower background noise) and with less interferences than those obtained with GC/MS. This is important as, often, less than 10 mg of hair are analyzed and consequently low concentration of GHB is registered. REFERENCES 1. P. Kintz, M. Villain, A.L. Pelissier, V. Cirimele and G. Leonetti, J. Anal. Toxicol. 29 (2005) 582. 2. M.H. Ghysel, Toxicorama XI (1999). 3. P. Kintz, J. For. Sci. 48 (2003) 195. CONCLUSION The sensitive, specific, and reproducible method appears suitable for the detection and quantification of GHB in human hair. The segmentation of hair in sexual assault cases is very important to differenciate endogenous production from a single exposure to GHB and to increase the window of detection. Waters is a registered trademark of Waters Corporation. Quattro micro GC, MassLynx and The Science of What s Possible are trademarks of Waters Corporation. All other trademarks are the property of their respective owners. 2007 Waters Corporation. Produced in the U.S.A. December 2007 720002249EN Waters Corporation 34 Maple Street Milford, MA 01757 U.S.A. T: 1 508 478 2000 F: 1 508 872 1990 www.waters.com