MULTIVARIABLE ROBUST CONTROL OF AN INTEGRATED NUCLEAR POWER REACTOR

Similar documents
Robust Performance Example #1

Assessment of an isolation condenser performance in case of a LOHS using the RMPS+ Methodology

Safety Analysis of Loss of Flow Transients in a Typical Research Reactor by RELAP5/MOD3.3

LQG/LTR ROBUST CONTROL SYSTEM DESIGN FOR A LOW-PRESSURE FEEDWATER HEATER TRAIN. G. V. Murphy J. M. Bailey The University of Tennessee, Knoxville"

APPLICATION OF D-K ITERATION TECHNIQUE BASED ON H ROBUST CONTROL THEORY FOR POWER SYSTEM STABILIZER DESIGN

Decoupled Feedforward Control for an Air-Conditioning and Refrigeration System

ANALYSIS OF THE OECD PEACH BOTTOM TURBINE TRIP 2 TRANSIENT BENCHMARK WITH THE COUPLED NEUTRONIC AND THERMAL-HYDRAULICS CODE TRAC-M/PARCS

FEL3210 Multivariable Feedback Control

Design of de-coupler for an interacting tanks system

Incorporating Feedforward Action into Self-optimizing Control Policies

Robust control for a multi-stage evaporation plant in the presence of uncertainties

MULTILOOP CONTROL APPLIED TO INTEGRATOR MIMO. PROCESSES. A Preliminary Study

Department of Engineering and System Science, National Tsing Hua University,

AADECA 2006 XXº Congreso Argentino de Control Automático ITERATIVE LEARNING CONTROL APPLIED TO NONLINEAR BATCH REACTOR E.J.

Robust and Optimal Control, Spring A: SISO Feedback Control A.1 Internal Stability and Youla Parameterization

D(s) G(s) A control system design definition

Feedback Structures for Vapor Compression Cycle Systems

Sensitivity Analyses of the Peach Bottom Turbine Trip 2 Experiment

A DIRECT STEADY-STATE INITIALIZATION METHOD FOR RELAP5

MIMO analysis: loop-at-a-time

THE RELEVANCE OF THE POWER-TO-FLOW MAP OF A BOILING WATER NUCLEAR REACTOR AS REFERENCE FOR STABILITY ASSESSMENT

SIMULATION SUITE CHEMCAD SOFTWARE PROCESS CONTROL SYSTEMS PROCESS CONTROL SYSTEMS COURSE WITH CHEMCAD MODELS. Application > Design > Adjustment

APPLICATION OF THE COUPLED THREE DIMENSIONAL THERMAL- HYDRAULICS AND NEUTRON KINETICS MODELS TO PWR STEAM LINE BREAK ANALYSIS

Table of Laplacetransform

Process Control, 3P4 Assignment 6

Self-Tuning Control for Synchronous Machine Stabilization

Analyzing the Stability Robustness of Interval Polynomials

Closed-loop system 2/1/2016. Generally MIMO case. Two-degrees-of-freedom (2 DOF) control structure. (2 DOF structure) The closed loop equations become

Design of Decentralised PI Controller using Model Reference Adaptive Control for Quadruple Tank Process

Improve Performance of Multivariable Robust Control in Boiler System

Lecture 12. Upcoming labs: Final Exam on 12/21/2015 (Monday)10:30-12:30

Evaluating the Safety of Digital Instrumentation and Control Systems in Nuclear Power Plants

DECENTRALIZED PI CONTROLLER DESIGN FOR NON LINEAR MULTIVARIABLE SYSTEMS BASED ON IDEAL DECOUPLER

Simulation of Quadruple Tank Process for Liquid Level Control

Advanced Power Plant Modeling with Applications to an Advanced Boiling Water Reactor and a Heat Exchanger

Generation of Bode and Nyquist Plots for Nonrational Transfer Functions to Prescribed Accuracy

Application of System Codes to Void Fraction Prediction in Heated Vertical Subchannels

SCWR Research in Korea. Yoon Y. Bae KAERI

ROBUST STABILITY AND PERFORMANCE ANALYSIS* [8 # ]

Fault Detection and Diagnosis of an Electrohydrostatic Actuator Using a Novel Interacting Multiple Model Approach

FEEDFORWARD CONTROLLER DESIGN BASED ON H ANALYSIS

NPP Simulators for Education Workshop - Passive PWR Models

Instability Analysis in Peach Bottom NPP Using a Whole Core Thermalhydraulic-Neutronic Model with RELAP5/PARCS v2.7

Automatic Control 2. Loop shaping. Prof. Alberto Bemporad. University of Trento. Academic year

ANALYSIS OF THE OECD MSLB BENCHMARK WITH THE COUPLED NEUTRONIC AND THERMAL-HYDRAULICS CODE RELAP5/PARCS

The exergy of asystemis the maximum useful work possible during a process that brings the system into equilibrium with aheat reservoir. (4.

The Dynamical Loading of the WWER440/V213 Reactor Pressure Vessel Internals during LOCA Accident in Hot and Cold Leg of the Primary Circuit

Simulation Study on Pressure Control using Nonlinear Input/Output Linearization Method and Classical PID Approach

POLITECNICO DI MILANO

Lectures on Applied Reactor Technology and Nuclear Power Safety. Lecture No 6

Design of Robust AMB Controllers for Rotors Subjected to Varying and Uncertain Seal Forces

Root Locus Design Example #4

De-Coupler Design for an Interacting Tanks System

Chapter 8. Design of Pressurizer and Plant Control

ROBUSTNESS COMPARISON OF CONTROL SYSTEMS FOR A NUCLEAR POWER PLANT

Closed loop Identification of Four Tank Set up Using Direct Method

GT-POWER linearization and engine advanced control design applications

ChE 6303 Advanced Process Control

DESIGN OF AN ON-LINE TITRATOR FOR NONLINEAR ph CONTROL

Index Accumulation, 53 Accuracy: numerical integration, sensor, 383, Adaptive tuning: expert system, 528 gain scheduling, 518, 529, 709,

AUTOMATED process control plays a key role in the. Robust Wide-Range Control of Steam-Electric Power Plants

Decentralized Feedback Structures of a Vapor Compression Cycle System

REACTOR OPERATOR-IN-THE-LOOP DYNAMIC MODELLING ABSTRACT 1 INTRODUCTION

Outline. Classical Control. Lecture 1

Title: Development of a multi-physics, multi-scale coupled simulation system for LWR safety analysis

LMI Based Model Order Reduction Considering the Minimum Phase Characteristic of the System

DESIGN OF ROBUST CONTROL SYSTEM FOR THE PMS MOTOR

H-Infinity Controller Design for a Continuous Stirred Tank Reactor

THERMAL STRATIFICATION MONITORING OF ANGRA 2 STEAM GENERATOR MAIN FEEDWATER NOZZLES

Modelling of Primary Frequency Control and Effect Analyses of Governing System Parameters on the Grid Frequency. Zhixin Sun

Principles and Practice of Automatic Process Control

Task 1 (24%): PID-control, the SIMC method

Lecture 6. Chapter 8: Robust Stability and Performance Analysis for MIMO Systems. Eugenio Schuster.

Stability Analysis of the Simplest Takagi-Sugeno Fuzzy Control System Using Popov Criterion

Multi-Loop Control. Department of Chemical Engineering,

University of Science and Technology, Sudan Department of Chemical Engineering.

Funnel control in mechatronics: An overview

Model Uncertainty and Robust Stability for Multivariable Systems

Design of Robust Controllers for Gas Turbine Engines

Applied Reactor Technology and Nuclear Power Safety, 4A1627; 4 cp. Course Description

LQG/LTR Robust Control of Nuclear Reactors with Improved Temperature Performance

Onset of Flow Instability in a Rectangular Channel Under Transversely Uniform and Non-uniform Heating

EL2520 Control Theory and Practice

Relationships between Load, Speed Regulation and Frequency. Slope= -R

APPLICATION OF ADAPTIVE CONTROLLER TO WATER HYDRAULIC SERVO CYLINDER

DEVELOPMENT OF A COUPLED CODE SYSTEM BASED ON SPACE SAFETY ANALYSIS CODE AND RAST-K THREE-DIMENSIONAL NEUTRONICS CODE

Uncertainty and Robustness for SISO Systems

ELECTRONICS & COMMUNICATIONS DEP. 3rd YEAR, 2010/2011 CONTROL ENGINEERING SHEET 5 Lead-Lag Compensation Techniques

EECE Adaptive Control

ABB PSPG-E7 SteamTMax Precise control of main and reheat ST. ABB Group May 8, 2014 Slide 1 ABB

ROBUST CONTROL OF MULTI-AXIS SHAKING SYSTEM USING µ-synthesis

COMPARISON OF TWO METHODS TO SOLVE PRESSURES IN SMALL VOLUMES IN REAL-TIME SIMULATION OF A MOBILE DIRECTIONAL CONTROL VALVE

DEVELOPMENT AND APPLICATION OF AN APPROACH TO ASSESS THE GLOBAL THERMAL EFFICIENCY OF A THERMAL ELECTRIC POWER PLANT

The moderator temperature coefficient MTC is defined as the change in reactivity per degree change in moderator temperature.

reality is complex process

Comparative analysis of decoupling control methodologies and multivariable robust control for VS-VP wind turbines

Presentation Topic 1: Feedback Control. Copyright 1998 DLMattern

On an internal multimodel control for nonlinear multivariable systems - A comparative study

Cost Analtsis for a Nuclear Power Plant with Standby Redundant Reactor Vessel

The Research of Heat Transfer Area for 55/19 Steam Generator

Transcription:

Brazilian Journal of Chemical Engineering ISSN 0104-6632 Printed in Brazil Vol. 19, No. 04, pp. 441-447, October - December 2002 MULTIVARIABLE ROBUST CONTROL OF AN INTEGRATED NUCLEAR POWER REACTOR A.Etchepareborda * and C.A.Flury Div. Control de Procesos, Centro Atómico Bariloche, Av. Ezequiel Bustillo km 9.500, (8400) S. C. de Bariloche - Prov. Río Negro, Argentina E-mail: etche@cab.cnea.gov.ar (Received: March 5, 2002 ; Accepted: May 27, 2002) Abstract - The design of the main control system of the CAREM nuclear power plant is presented. This plant is an inherently safe low-power nuclear reactor with natural convection on the primary coolant circuit and is self-pressurized with a steam dome on the top of the pressure vessel (PV). It is an integrated reactor as the whole primary coolant circuit is within the PV. The primary circuit transports the heat to the secondary circuit through once-through steam generators (SG). There is a feedwater valve at the inlet of the SG and a turbine valve at the outlet of the SG. The manipulated variables are the aperture of these valves and the reactivity of the control rods. The control target is to regulate the primary and secondary pressures and to monitor steam flow reference ramps on a range of nominal flow from 100% to 40%. The requirements for the control system are robust stability, low-order simple controllers and transient/permanent error bounding. The controller design is based on a detailed RETRAN plant model, from which linear perturbed open-loop dynamic models at different powers are identified. Two low-order nominal models with their associated uncertainties are chosen for two different power ranges. Robust controllers with acceptable performances are designed for each range. Numerical optimization based on the loop-shaping method is used for the controller design. The designed controllers are implemented in the RETRAN model and tested in simulations achieving successful results. Keywords: multivariable robust control, loop-shaping, identification, nuclear power plants. INTRODUCTION CAREM is a nuclear power reactor under development by CNEA (Comisión Nacional de Energía Atómica) and INVAP SE. A schematic plant drawing is shown in Figure 1. It is an inherently safe low-power nuclear reactor with natural convection on the primary coolant circuit and is self-pressurized with a steam dome on the top of the pressure vessel (PV). It is an integrated reactor as the whole primary coolant circuit is within the PV. The primary circuit transports the heat to the secondary circuit through once-through steam generators (SG). There is a feedwater valve at the inlet of the SG and a turbine valve at the outlet of the SG. The manipulated variables (U) are the aperture of these valves (Afwv and Atv) and the reactivity of the control rods (Rcr). The control target is to regulate the primary and secondary pressures (Pp and Ps) and to monitor steam flow (Ws) reference ramps on a range of nominal flow from 100% to 40%. The requirements for the control system are robust stability, low-order simple controllers and transient/permanent error bounding. The robust control design procedure (Sánchez Peña and Sznaier, 1998) requires a nominal model of a plant and a description of the uncertainty between the model and the actual process provided in the frequency domain. There are some previous applications of this technique to nuclear reactor power control. Suzuki et al. (1993) designed an H inf robust power controller for a simple seventh-order *To whom correspondence should be addressed

442 A.Etchepareborda and C.A.Flury Boiling Water Reactor model. Weng et al. (1994) and Power and Edwards (1995) designed a robust wide-range power controller for a simple tenth-order Pressurized Water Reactor (PWR) model. All these design approaches result in controllers of orders similar to the order of the nominal plant. As a consequence implementation of the controllers is impractical for complex high-order plants. They are also based on simple nonlinear models of the plant, which are indeed approximations of the real plant, and have their own uncertainties. The main control systems of traditional PWR designs consist of several SISO control loops. In the primary cooling system the nuclear power is controlled by the reactivity of the control rods, the Pp is controlled by heaters and showers in a pressurizer and the coolant flow is fixed. In the secondary cooling system the pressure is normally controlled by the turbine valve. As opposed to traditional PWR designs, in the CAREM plant the nuclear power is strongly coupled with the Pp and the primary flow. The inlet temperature and flow to the SG on the secondary side are also coupled with the Pp. Therefore multivariable control must be considered in controller design. In this work the design of the main control loops of the CAREM plant is presented. The plant to be controlled is a RETRAN (EPRI, 1988) nonlinear neutronic and thermohydraulic detailed model developed for engineering calculations with several hundred internal variables. Identification techniques are applied to this model in several power ranges. Analysis of the identified models allows definition of two nominal models with their associated uncertainties for both the high-power range (above 75%) and the low-power range. In section 2 we describe this identification process. Based on these models with their associated uncertainties, a simple robust low-order controller is obtained for each power range with a numerical optimization technique based on the loop-shaping method (Skogestad and Postlethwaite, 1996). This is described in section 3. The controllers are embedded in the RETRAN model and the design specifications are verified by simulation. These results are presented in section 4. Finally the conclusions of this work are presented in section 5. Figure 1: Schematic drawing of the CAREM plant. Brazilian Journal of Chemical Engineering

Multivariable Robust Control 443 IDENTIFICATION Starting from five different RETRAN model stationary states, each input is successively perturbed through small amplitude test signals, like chirp and pseudorandom binary sequences (PRBS). The amplitude of the test signals selected was small enough to avoid appreciable nonlinear effects on the plant response. With the input-output response to the chirp signals, nine parametric models are identified for each of the input-output combinations, following a least squares error procedure, (Ljung, 1987). The structures and orders of the parametric models were selected using the RETRAN model response to PRBS as validation sets. From these models, nine transfer functions with their associated uncertainties are obtained. These constituted an identified model at each stationary power point. The identified models are reduced by gramian-based balancing and truncation (Sánchez Peña and Sznaier, 1998). Choosing as nominal models a reduced model (of about 20 state variables) for high power (from 75% to 100% full power) and another reduced model for low power (from 40% to 75%), we determine the highest singular value of the uncertainties considering both the appropriate uncertainties of the specific identification process and the differences between the identified models at other powers in the range and the nominal model. The criteria for the selection of the reduced models as nominal models was the minimum highest singular value for the associated uncertainty. The definition of two ranges is because with only one range the magnitudes of the highest singular value for the uncertainties at low frequency rise above the 0 db (see Figure 2), and thus a robust controller for the entire power range (40% to 100%) cannot be obtained. Figure 2: Highest singular values of W as a function of frequency. Solid line: low-power range with the 43 % reduced model as the nominal model. Dashed line: high-power range with the 88 % reduced model as the nominal model. Dotted line: entire power range (40% to 100%) with the 75% reduced model as the nominal model. CONTROLLER DESIGN Relative gain array (RGA) analysis (Skogestad and Postlethwaite, 1996) indicates that Pp can be independently controlled with Rcr alone and that both Ws and Ps must be controlled with Afwv in conjunction with Atv. Based on these results, in Eq. (1) a block diagonal structure is selected for the controller that uncouples the primary and secondary control loops, where the integral terms on the diagonal elements are included to obtain bounded errors for ramp inputs: Brazilian Journal of Chemical Engineering, Vol. 19, No. 04, pp. 441-447, October -December 2002

444 A.Etchepareborda and C.A.Flury ( τ + ) τ + ( τ + ) ( τ + ) K11 z11s 1 /s( p11s 1) K12 z12s 1 / p12s 1 0 K(s) = K21( τ z21s + 1 )/( τ 21s + 1) K 22( τ 22s + 1)/s( τ p22s + 1) 0 0 0 K 33( τ 33s+ 1)/s( τ p33s+ 1) (1) The block diagram of the controlled system is shown in Figure 3. The plant is represented by the nominal system transfer matrix, Gu0(s), and the associated uncertainty transfer matrix, W s). The input to the plant is ( Atv Afwv Rcr) T u =, the output is y= ( Ps Ws Pp) T and the reference input is ( ) T r= Psref Wsref Ppref, where subscript ref denotes reference signal and is any transfer matrix such that 1. The uncertainties in the actuators are represented through an external perturbation, u, with G wu its associated dynamic weight matrix. W r is the reference input weight matrix and W e is the output error weight matrix, defined in order that transient error bound is allowed to double the ramp following permanent error bound. To satisfy the criteria of robust stability and nominal performance a loop-shaping design procedure is implemented through a numerical optimization method in order to obtain the parameters of K(s). An F cost function that measures the mean distance from the actual loop transfer matrix, L(s), to a desired transfer matrix, L D (s), is defined. This desired transfer matrix is of the type K/s, with the gain K defined in order to obtain a 0 db crossover frequency ω c compatible with the uncertainties associated to the family of models. The F cost function has a term that measures: lower than desired gain at low frequencies (F lf ), higher than desired gain at high frequencies (F hf ) and higher than desired peak gain on the closed-loop transfer matrix, (F T ). The optimization process obtains the controller parameters, K ij, τ zij and τ pij, that minimizes the cost function F subject to the following set of constraints: stable closed-loop system; stable and minimum phase controller and limitations on the maximum frequency for the poles and zeros of the controller related to a limited sampling frequency (aliasing). The relative weight of the F cost function terms are adjusted, based on the results of the optimization process. A higher weighting of the F lf term implies higher performance; of the F hf term, improved robustness; and of the F T term, improved transient performance. The singular values for L(s), L D (s) and the closed-loop transfer matrix T(s), together with the inverse magnitude of the maximum singular value of the uncertainties W at high frequencies, are given in Figure 4. The nominal and robust performance condition is evaluated separately for each external perturbation w and for the reference input r in order to analyze the relative sensitivity of the output error with respect to these external signals and to modeling uncertainty. As an example, the maximum slope for the reference input to the nominal plant in the range of 75% to 100%, is reduced a factor of two if uncertainties are considered. SIMULATION RESULTS The controllers are implemented in the RETRAN model and the design specifications are verified by simulation. Ramp properties are shown in Figure 5. A 1%/min and a 3%/min steam flow ramp are simulated for the low- and the high-power range. The control is switched from the low- to the highpower range just before the 3%/min steam flow ramp. The output errors are shown normalized with respect to the admissible steady-state error bounds. These are the steam flow error (Ws ref -Ws), the secondary pressure error (Ps ref -Ps) and the primary pressure error (Pp ref -Pp). Note that the errors are within the transient admissible error bounds, which are twice these admissible steady state bounds. Brazilian Journal of Chemical Engineering

Multivariable Robust Control 445 Figure 3: Block diagram of the controlled system. Figure 4: Controller design results: singular values of L(s), L D (s) and T(s). Brazilian Journal of Chemical Engineering, Vol. 19, No. 04, pp. 441-447, October -December 2002

446 A.Etchepareborda and C.A.Flury Figure 5: Time evolution of nuclear power and output variable errors. CONCLUSIONS Two stable, robust, low-order and simple controllers were designed for both high- and lowpower operation of the CAREM reactor. A steam flow ramp capacity of 3 %/min and 1 %/min is observed for the high- and the low-power range, respectively, within a restrictive error bound, showing an acceptable performance of the controllers. Sensitivity to external perturbations is also evaluated as acceptable although the results are not presented in this work. An accurate determination of the nominal models with the associated uncertainties is successfully obtained by use of model identification techniques for a complex and detailed engineering model of the plant. This fact encourages the later use of this technique in the real plant. In this case, the numerical optimization used for the synthesis of the controllers was effective in easily balancing robustness, performance and transient behaviour requirements. The controller will have to be verified when a more detailed model of the feedwater system, the turbine-generator system and the control rod mechanisms are incorporated in the RETRAN model. The life cycle of the nucleus, switching between controllers, and extension to 20% of full power will also have to be considered. ACKNOWLEDGMENT We express our gratitude to the people that worked for the CAREM project at CNEA and INVAP SE. Brazilian Journal of Chemical Engineering

Multivariable Robust Control 447 REFERENCES Edwards, R.M., Lee, K.Y. and Ray, A. (1992) Robust Optimal Control of Nuclear Reactors and Power Plants, Nuclear Technology, 98:137-148. EPRI (1988) RETRAN-02- A Program for Transient Thermal-Hydraulic Analysis of Complex Fluid Flow Systems, El International, Inc., Idaho Falls. Ljung, L. (1987) System Identification: Theory for the User, Prentice-Hall Inc., Englewood Cliffs, New Jersey. Power, M.A. and Edwards, R.M. (1995) Implementation of Robust Control Experiments on a Nuclear Reactor, In Proceedings of the Ninth Power Plant Dynamics and Control Conference, Knoxville, TN. Sánchez Peña, R.S. and Sznaier, M. (1998) Robust Systems, Theory and Applications, Wiley- Interscience, New York. Skogestad, S. and Postlethwaite, I. (1996) Multivariable Feedback Control: Analysis and Design, John Wiley & Sons, Chichester. Suzuki, K., Shimazaki, J. and Shinohara, Y. (1993) Application of H inf Control Theory to Power Control of a Nonlinear Reactor Model, Nuclear Science and Engineering, 115:142-151. Weng, C.K., Edwards, R.M. and Ray, A. (1994) Robust Wide Range Control of Nuclear Reactors By Using the Feedforward-Feedback Concept, Nuclear Science and Engineering, 117:177-185. Brazilian Journal of Chemical Engineering, Vol. 19, No. 04, pp. 441-447, October -December 2002