Temperature Calibration

Similar documents
Hot solutions for temperature measurement. Contact and non-contact thermometers from Fluke

CALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006%

THERMOCOUPLE CHARACTERISTICS TRAINER

THERMYS 150. Advanced field reference thermometer / temperature calibrator

Lecture 36: Temperatue Measurements

Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure

The Fluke 66 and 68 Infrared Thermometers

Part Number Range Accuracy Printing WP * Probe Special User LDC with Page Logging included Feature Cal Backlight

Welcome. Functionality and application of RTD Temperature Probes and Thermocouples. Dipl.-Ing. Manfred Schleicher

HL-800K Infrared Laser Thermometer. -50 C to +800 C (13:1 ratio) User Manual

15. Compare the result with the value you have taken above Compare the calculated pressure value with the actual pressure value that you have

CALYS 80P. Field pressure calibrator with high accuracy 0.01%

IR and contact thermometers

Temperature Scales. Temperature, and Temperature Dependent on Physical Properties. Temperature. Temperature Scale

INF195 Infrared Thermometer

IR 80-H. Non-Contact Infrared Temperature Sensor/Transmitter. Temperature Range: 500~1700

Infrared Temperature Calibration 101 Using the right tool means better work and more productivity

OPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000

Measurements & Instrumentation. Module 3: Temperature Sensors

1551A Ex/1552A Ex Intrinsically Safe Stik Thermometer. The new gold standard of industrial temperature calibration

MODEL: MO Digital DC Milliohm Meter OPERATING INSTRUCTION

792A AC/DC Transfer Standard

Stick-Style Water-Resistant Infrared Thermometer for Foodservice Applications with 4:1 Distance-to-Sight Ratio Model

DATA SHEET. Thermocouple module with digital I²C-Interface - THMOD-I²C. Characteristic features. Areas of application. Features.

MEASURING INSTRUMENTS

Infrared / K Thermometer Remote Temperature Measurement ( Non-Contact ) 1327K INSTRUCTION MANUAL

792A AC/DC Transfer Standard

473-SHX Dew Point Mirror

Professional Article. Fire and Ice

Veerapong Kanchanawongkul*

User Manual. Stick-Style Water-Resistant Infrared Thermometer with 8:1 Distance-to-Sight Ratio. Model with NIST-Traceable Calibration

Model ST-616CT. Instruction Manual. Infrared Thermo-Hygrometer. reedinstruments. www. com

5730A High Performance Multifunction Calibrator. Extended specifications

Introduction to Blackbody Sources

Temperature Measurements

Section 7. Temperature Measurement

SCTP20 Programmable 2-Wire Temperature Transmitter, Head Mount

Traceable Big-Digit Type-K Thermometer Big digits are readable from 15 feet away. For additional Type-K probes, see page 41.

566/568. Infrared Thermometers. Getting Started

Infrared Thermometer Calibration A Complete Guide

Lab E3: The Wheatstone Bridge

Temperature. 3

Lecture 11 Temperature Sensing. ECE 5900/6900 Fundamentals of Sensor Design

Thermal Mass Flow Meter for Gases

Temperature Measurement

Thermocouple Calibrations and Heat Transfer Coefficients

Good practice guide containing experimental results and recommendations for the selection, preparation and calibration of the temperature sensors

High Accuracy High Speed in Your Process

MN-ISO-2000FN-E. ISO-2000FN COATING THICKNESS GAGE OPERATION MANUAL

IC Temperature Sensor Provides Thermocouple Cold-Junction Compensation

Using a Mercury itc with thermocouples

I. Introduction and Objectives

1 THE CONCEPT OF TEMPERATURE

Sensors and Actuators Sensors Physics

Resistivity and Temperature Coefficients (at 20 C)

Tried. Tested. Trusted. A Guide to. Temperature Measurement

Dual laser + type K thermometer INFRARED THERMOMETER

473 Dew Point Hygrometer

Module 4 : THERMOELECTRICITY Lecture 21 : Seebeck Effect

A Case for Periodic Calibration or Verification of RTDs

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

Pressure Display Controller

Measurement of Temperature in the Plastics Industry

INFRARED THERMOMETER Model : TM-959

IR 40. Non-Contact Infrared Temperature Sensor/Transmitter. Temperature Range: 0~1000

INFRARED THERMOMETER TM0819

ED 701 General Industry Pressure Transmitter

Understanding uncertainties associated with the 5128A RHapid-Cal Humidity Generator

ASEN 2002 Experimental Laboratory 1: Temperature Measurement and an Blow Dryer Test

473 Dew Point Hygrometer

4. Thermometry. Temperature and Heat Flow Temperature Scales Thermometers

VIBRATION METER. Instruction Manual.

I m. R s. Digital. R x. OhmmetersxSeries Shunt Digital. R m

TEMPERATURE AND THERMAL EXPANSION

RADIO AMATEUR EXAM GENERAL CLASS

Temperature. Sensors. Measuring technique. Eugene V. Colla. 10/25/2017 Physics 403 1

T h e rm i s t o r s

Temperature control for Varian Cary line of UV/Vis Spectrophotometers and the Eclipse Fluorometer

Differential ph Probe Type 18

THM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist

DUBLIN INSTITUTE OF TECHNOLOGY Kevin Street, Dublin 8.

Flexitest Switch Assemblies Type FT-19R and FT-19RX Supersedes DB March 2008

HIGH CURRENT BRIDGE DRIVER and 4-20mA Transmitter

D501 and D501-RS. Microscanner D-Series IR Thermometers. no effect. no effect. no effect. no effect no effect

SINEAX VK 626 Programmable Temperature Transmitter for RTD and TC inputs, with HART protocol

Digital Controller Operation

Process Control & Design

- Copyright Dewesoft d.o.o., all rights reserved. Temperature measurement

X-ray fluorescence analysis - calibration of the X-ray energy detector

Exp. P-6 Blackbody Radiation

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

ph / Temperature Meter for Cheese with Application Specific Probe

Emissivity: Understanding the difference between apparent and actual infrared temperatures

TS02 - Pre-Instructional Survey

Community College of Allegheny County Unit 9 Page #1. Thermocouples R1 = 1K

Edgetech Instruments Inc.

SEN TRONIC AG 1 A 6 6 / "

Determine the Inside Wall Temperature of DSTs using an Infrared Temperature Sensor

Transcription:

Temperature Calibration Application Note Temperature plays a key role in many industrial and commercial processes. Examples include monitoring cooking temperature in food processing, measuring the temperature of molten steel in a mill, verifying the temperature in a cold storage warehouse or refrigeration system, or regulating temperatures in the drying rooms of a paper manufacturer. A temperature transmitter will use a measuring device to sense the temperature, and then regulate a 4-20 feedback loop to a control element that affects the temperature (Fig. 1). The control element might consist of a valve 2200 ºC that opens or closes to allow more steam into a heating process or more fuel to a burner. The two most common types of temperature sensing devices are the thermocouple () and resistive temperature detector (). provides a broad range of temperature calibration tools to help you quickly and reliably calibrate your temperature instrumentation. A summary of the temperature calibration capabilities of Process Tools is shown below. 4 Wire Transmitter 4 to 20 ZERO SPAN 300 250 200 150 100 50 Sensor 0-200 -100 0 100 200 300 400 Ohms s. Temp (PT100) Figure 1. 724 Temperature Calibrator Function Temperature Test Tools 712 714 724 Function 725 726 741 712 743 714 744 724 55XX 725 50 Series Tem- Measure temperature from an probe Measure temperature from an Measure temperature from a T/C probe probe Simulate an output Tem- Simulate an into pulsed excitation current Function Simulate a T/C output Measure temperature from an Simultaneous output a T/C, measure probe Simultaneous output an, measure probe Log a temperature measurement Ramp a temperature signal Loop power supply Multifunction Source and Measure probe Automatically calibrate temperature switches Simulate an output Electronic data capture Upload documented data to PC Integrated HART communication Simulator measure characterized Simulate an output Measure temperature from a T/C Measure temperature from a T/C 712 714

3W 4W RECALL / URE LOOP URE Typical Temperature Calibration Applications How to calibrate a Thermocouple input transmitter STORE SETUP 724 TEMPERATURE CALIBRATOR 30 ALL TERMINALS The 724 Temperature Calibrator can provide the three things necessary to calibrate a temperature transmitter. You can source a temperature, provide loop power, and measure the resulting output current. The following example shows how to calibrate a Type K transmitter that is ranged from 0-150 degrees centigrade, generating an output current range from 4-20. Basic Calibrator Setup 1. Connect the 724 test leads to the transmitter as shown. The output from the thermocouple jacks on the 724 will simulate a temperature input to the transmitter. The red and black test leads will provide loop power to the transmitter and will measure the current resulting from temperature changes into the transmitter. 2. Power on the 724 calibrator. Select the button and the LOOP button to select measure milliamps with 24 loop power applied. COM LOOP COM C F 100% 25% 25% 0% TEST DC PWR ++ Rosemount 444 3. Press the Meas/Source button until the lower portion of the 724 display indicates the source mode. 4. Depress the button until a type of K is displayed. 5. Select the C button for centigrade. 6. Set the Zero Point for this application into the Calibrator. To do this set the display initially to 0.0 C. You can use the up and down arrow keys to change the output value. Use the left and right arrows to control which decade value of the display is being changed. When the display reads 0.0, hold down the 0 % key on the 724 and observe that 0 % is displayed in the lower right corner of the screen. This establishes the Zero point for calibration. 7. Set the Span Point in the Calibrator. Set the display to the desired Span value for calibration. In this example the display should read 150 C. Depress the 100 % key and observe that 100 % is displayed in the lower right corner of the screen. This establishes the Span point for calibration. Temperature transmitter error calculation example Measurement Source T Span Formula Error % 4.02 0 C 150 C ([4.02-4)/16]-[0/150])*100 0.1250 11.95 75 C 150 C ([11.95-4)/16]-[75/150])*100-0.3125 20.25 150 C 150 C ([20.25-4)/16]-[150/150])*100 1.5625 Performing an As Found Test 8. Depress the 0 % key; record the applied temperature and the corresponding measurement. 9. Depress the 25 % key (2) times; record the applied temperature and the corresponding measurement. 10. Depress the 100 % key; record the applied temperature and the corresponding measurement. 11. Calculate the errors for each of the (3) points using the following formula: ERROR = ([(I-4)/16]-[(T/TSPAN])*100 where Error is in % of span, I is your recorded measurement, T is the recorded temperature and TSPAN is the temperature input span (100 % - 0 % points). The error calculation table below shows how to apply the formula to actual recorded measurements. 12. If your calculated errors are less than the specified instrument tolerance, the transmitter has passed the As-Found test. If the test has not passed, perform adjustments as necessary. Adjusting the Transmitter 13. Depress the 0 % key to source the proper temperature for a 4 output. Adjust the zero potentiometer until the current reading is 4.00. 14. Depress the 100 % key to source the proper temperature for a 20 output. Adjust the Span potentiometer until the current reading is 20.00. 15. Depress the 0 % key again and adjust the zero potentiometer again if necessary, to get a 4.00 output. Perform an As Left Test Repeat steps 8 through 12 to complete the full calibration procedure on your temperature transmitter. 2 Corporation Temperature Calibration

CAT CLEAR (ZERO) RANGE 30 30 CAT CLEAR (ZERO) RANGE DOCUMENTING PROCESS CALIBRATOR CAT 30 CLEAR (ZERO) 300 743B DOCUMENTING PROCESS CALIBRATOR 743B DOCUMENTING PROCESS CALIBRATOR SETUP SETUP Hz Hz 7 8 9 7 8 9 4 5 6 4 5 6 1 2 3 1 2 3 30 0. 30 30 300 ENTER Input Indicator Setpoint ler 30 0. 30 30 300 ENTER Input Indicator Setpoint ler Output or Alarm A B Disconnected T/C Measured led Process Output or Alarm A B Disconnected T/C Measured led Process Fuel Supply alve Sourcing temperature, documented indicator verification The performance of a temperature indicator can be verified by applying a calibrated signal to the sensor input and noting the results. The performance of the indicator can be documented using the 740 series calibrators by entering the indicator value using the keypad. Please see the Custom Units/User Entered alues application note, listed on page 7, for more information and instructions. Fuel Supply alve erifying thermostat or temperature controllers The performance of a thermostat or temperature controller can be determined by measuring the outputs while applying a temperature signal to the input. In this example, a 740 series calibrator simultaneously varies the input signal while monitoring contact closure on the output. The calibrator then documents the measured setpoint, reset point and deadband size. See the Limit Switch application note, listed on page 7, for more information on switch testing. HART Connection 714 THERMOCOUPLE CALIBRATOR Probe 744 + 1 2 3 4 TYPE C/ F Setpoint ler + T 5 INPUT OUTPUT T/C Input Measured led Process Hz 7 8 9 4 5 6 SETUP 3144 Transmitter 30 Output 1 2 3 0. ENTER + Red Fuel Supply alve Black Measuring temperature Process temperatures can be verified using a temperature calibrator or digital thermometer. In this example, both the controller/indicator and its input sensor can be verified at the process operating temperature. Precision Temperature Measurement Use characteristic probes with the 726 Precision Multifunction Process Calibrator for enhanced temperature measurement accuracy. See application note Pressure Calibration for details (lit# 1281620). Calibrate a HART temperature transmitter HART smart transmitters require digital adjustment if found to be out of specification. This task requires a precision calibrator and a digital configuration tool. The 744 shown is connected to a Rosemount 3144 HART temperature transmitter. In this configuration, the 744 applies a T/C simulation signal and measures the output and digital P. If adjustment is necessary, sensor trim, output trim and re-ranging can be performed with the 744. See the HART application note, listed on page 7. 3 Corporation Temperature Calibration

712 Calibrator Improved temperature accuracy to 0.2 C Output ramping Measure or simulate Pt 100 200 500 1000 (385), Pt 100 (3926), Pt 100 (3916) and Ni 120 (672) Measure or source 15 Ω to 3200 Ω Handles pulsed transmitters Selectable F or C Banana jacks for 2 W, 3 W or 4 W measurements 714 Thermocouple Calibrator Improved temperature accuracy to 0.4 C Output ramping Measure or simulate JKTER SBLU thermocouples Measure or source -10 to 75 m Selectable F or C Thermocouple mini-jack termination 724 Temperature Calibrator Measure or simulate JKTERS BLUN thermocouples Measure or simulate 7 types (see 712) Measure or source DC, Ω Measure 24, with or without 24 volt loop supply Source or while measuring or Handles pulsed transmitters with pulses >5 ms 725 Multifunction Process Calibrator All the temperature capabilities of 724, plus: Measure pressure with 700Pxx Pressure Modules Source or measure frequency to 10 khz Source signals 4 Corporation Temperature Calibration 726 Precision Multifunction Process Calibrator All the capabilities of the 725 plus: 0.01 % accuracy Error calculation Characterized constants Enhanced measurement accuracy Measure and source pulse totalization 741, 743 and 744 Documenting Process Calibrators Measure or simulate JKTERS- BLUNC thermocouples Measure or simulate 7 types, per 712 below, plus Cu 10 (47) Source or measure volts, ohms,, frequency Measure pressure with 700Pxx Pressure Modules Electronically capture results of automated procedures Serial communication to PC (743, 744) HART communication (744)

51 Single Input Digital 52 Dual Input Digital 53 Single Input Digital with data logging 54 Dual Input Digital with data logging 68 Infrared 62 Mini Infrared 51 Series II and 52 Series II Large backlit dual display shows any combination of T1, T2 (52 only), T1-T2 (52 only), plus MIN,, or AG Relative time clock on MIN,, and AG provides a time reference for major events Electronic Offset function allows compensation of thermocouple errors to maximize overall accuracy Measures J, K, T, and E-types of thermocouples Readout in C, F, or Kelvin (K) The 53 Series II and 54 Series II Include all the features listed for the 51 and 52 Series II plus: Data Logging up to 500 points of data with user adjustable recording interval Additional thermocouple types R, S, and N (for a total of 7 different types) Real time clock captures the exact time of day when events occur Recall function allows logged data to be easily reviewed on the meter display IR communication port allows data to be exported to optional iew Temperature PC software for further analysis and graphing 62, 63, 66 and 68 Infrared s Range: 62 = -30 to 500 C (-20 to 932 F) 63 = -32 to 535 C (-25 to 999 F) 66 = -32 to 600 C (-25 to 1100 F) 68 = -32 to 760 C (-25 to 1400 F) Distance to spot: 62 = 10:1, 63 = 12:1, 66 = 30:1, 68 = 50:1 @ 80 % energy Laser guided, backlit 12-point data logging (66, 68) Hi-resolution optics 1 % accuracy.5 % repeatability temp display (62, 63) MIN//DIF/AG and Hi/Lo alarm (66, 68) Adjustable emissivity (66, 68) 572 Infrared 574 Infrared 576 Infrared 572, 574 and 576 Infrared s Range: -30 to 900 C (-25 to 1600 F) 0.1 C resolution up to 900 Bright laser beam for easy targeting 60:1 distance to spot ratio MIN/ reading capture Large backlit dual display 5 Corporation Temperature Calibration 5500/5520 Multiproduct Calibrator erify and probes Calibrate most handheld multimeters and temperature calibrators Calibrate most functions of Process Calibrators Laboratory accuracy Hart Scientific 9009 Industrial Dual-Block Calibrator See the Process Tools Selection Guide for more information on Hart dry-wells, calibrators, thermocouple furnace, thermometers, micro-baths, thermohydgrometer and other tools.

Temperature Test Tool Summary Performance: Selected examples 744 743/743B 741/741B 725 726 724 714 712 53/54 51/52 Function Range Resolution Accuracy Notes Measure -200 to 800 C 0.1 C 0.3 C 8 types PT100-385 Simulate -200 to 800 C Measure -200 to 800 C 0.1 C 0.33 C 7 types PT100-385 Simulate -200 to 800 C 0.1 C 0.33 C Measure -200 to 800 C 0.01 C 0.15 C 8 Types PT 100-385 Source -200 to 900 C 0.01 C 0.15 C Resistance Measure 0 to 11,000 Ω.01 Ω.05 % + 50 mω 100 Ω range Simulate 0 to 11,000 Ω.01 Ω.01 % + 40 mω Resistance Measure 15 to 3200 Ω 0.1 Ω.1 Ω to 1 Ω 100 Ω range Simulate 15 to 3200 Ω 0.1 Ω.1 Ω to 1 Ω Resistance Measure: 5 to 4000 Ω 0.01 to 0.1 Ω 0.015 % 100 Ω range Source: 5 to 4000 Ω Thermocouple Measure -202 to 1374 C 0.1 C 0.3 C JKTERSBLUNC Type K Simulate -202 to 1374 C 0.1 C 0.3 C Thermocouple Measure 0.1 C <1000 C 0.05 % rdg JKTERSN Type K -200 to 1372 C 0.1 C >1000 C + 0.3 C Thermocouple Measure 0.1 C <1000 C 0.05 % rdg JKTE Type K -200 to 1372 C 0.1 C >1000 C + 0.3 C Thermocouple Measure -200 to 1370 C 0.1 C 0.3 C + 10 µ JKTERSBLU plus Type K Simulate -200 to 1370 C 0.1 C 0.3 C + 10 µ N on 724, 725, 0.2 C on 726 XK, BP on 726 m Measure 0 to 110 m 0.001 m.25 % +.015 % FS Source 0 to 110 m 0.001 m.01 % +.005 % FS m Measure -10 to 75 m 0.01 m.025 % + 1 count Source -10 to 75 m 0.01 m.025 % + 1 count m Measure 0 to 100 m 0.01 m 0.01 % + 1 count Source 0 to 100 m Measure 0-24 0.001.020 % + 2 count Measure 0-24 0.001.010 % +.015 % FS Measure Measure 0 to 24 0.001 0.01 % + 2 counts Source 0 to 24 Loop Power Supply 24 dc n/a ±10 % Temperature Terminology Dry Well Calibrator: A temperature calibrator that uses a precision oven to source precise temperature. This style of calibrator is often used for the verification of temperature sensors. Excitation current: A constant current applied to an probe to determine actual resistance for temperature measurement. Typical values are 2 or less to minimize self-heating of the probe. IPTS-68: International Practical Temperature Scale of 1968. A temperature standard adopted in 1968 that uses intrinsic standards to define the measurement of temperature. ITS-90: International Temperature Scale of 1990. A temperature standard adopted in 1990 that uses intrinsic standards to define the measurement of temperature. This standard modifies the intrinsic standards of IPTS-68 with additional intrinsic references. Lead Resistance Compensation: A compensation method used with 3 and 4 wire s and resistance measurement. This method negates the error associated with lead resistance when making an measurement. Reference Temperature: The temperature at which a thermocouple temperature measurement is referenced. For Calibration tools, this is the temperature where the thermocouple miniplug is connected to the calibrator. R The resistance value of an probe at 0 C. Example PT100-385, R = 100 Ω. : Resistance Temperature Device, a temperature measurement sensor that has predictable changes in resistance with a change in temperature. The most common is the platinum PT100-385. Seebeck Effect: Thermoelectric effect in which the voltage potential increases with temperature (thermocouples) in a junction of dissimilar metals. Triple point of water: This temperature reference point is the intrinsic standard at which water is liquid, ice and gas. This reference point defines 0.01 C. 6 Corporation Temperature Calibration

Thermocouples Alloys Plug Temperature Color + - Range EMF Range White Pt-30 % Rh Pt-6 % Rh 600 to 1820 C, 1.792 to 13.820 m Platinum- Platinum- 1112 to 3308 F B 30 % Rhodium 6 % Rhodium Red W-5 % Re W-26 % Re 0 to 2316 C, 0 to 37.079 m Tungsten- Tungsten- 32 to 4201 F C 5 % Rhenium 26 % Rhenium Purple Ni-Cr Cu-Ni -250 to 1000 C, -9.719 to 76.370 m Nickel- Copper-Nickel -418 to 1832 F E Chromium (Constantan) (Chromel) Black Iron Fe Cu-Ni -210 to 1200 C, -8.096 to 69.555 m Copper-Nickel -346 to 2193 F J (Constantan) Yellow Ni-Cr Ni-Al -200 to 1372 C, -5.891 to 54.886 m Nickel- Nickel- -328 to 2502 F K Chromium Aluminum (Chromel) Blue Fe Cu-Ni -200 to 900 C, -8.166 to 53.147 m Iron Copper-Nickel -328 to 1652 F L (Constantan) Orange Ni-Cr-Si Ni-Si-Mg -200 to 1300 C, -3.990 to 47.514 m Nickel-Chromium- Nickel-Silicon- -328 to 2372 F N Silicon Magnesium (Nicrosil) (Nisil) Green Pt-13 % Rh Pt -20 to 1767 C, -0.101 to 21.089 m Platinum- Platinum -4 to 3213 F R 13 % Rhodium Green Pt-10 % Rh Pt -20 to 1767 C, -0.103 to 18.682 m Platinum- Platinum -4 to 3213 F S 10 % Rhodium Blue Cu Cu-Ni -250 to 400 C, -6.181 to 20.873 m Copper Copper-Nickel -418 to 752 F T (Constantan) White Cu Cu-Ni -200 to 600 C, -5.693 to 34.320 m Copper Copper-Nickel -328 to 1112 F U Temperature Conversion F 4352 4172 3992 3812 3632 3452 3272 3092 2912 2732 2552 2372 2192 2012 1832 1652 1472 C 2400 2300 2200 2100 2000 1900 1800 1700 1600 1500 1400 1300 1200 1100 1000 900 800 Fixed Points of ITS-90 961.78 C Silver freezing point Application Assistance To get copies of these application notes, contact your sales organizations, or go to www.fluke.com. 1292 1112 700 600 660.323 C Al freezing point Application Note Literature Number Understanding Specifications 1261947 Transmitter Calibration 262393 HART Transmitter Calibration 1262439 Limit Switches 1263879 Custom Units 1263925 Pressure Calibration 1281620 Temperature Calibration 1560369 Loop Calibration and Maintenance 1627722 Troubleshooting Process Loops 1989137 Calibrating a Pressure Switch with a DPC 2069058 Dry-Well Calibrators 2088275 Selecting a Dry-Well 2088282 Eliminating Sensor Errors in Loop Calibrations 2148146 932 500 752 400 572 300 392 200 212 100 32 0-148 -100-328 -200-459 -273 419.527 C Zinc freezing point 231.928 C Tin freezing point 156.5985 C Indium freezing point 29.7646 C Gallium melting point 0.01 C H2O triple point -38.8344 C Mercury triple point -189.3442 C Argon triple point -218.7916 C Oxygen triple point -248.5939 C Neon triple point -259.3467 C Hydrogen triple point 7 Corporation Temperature Calibration

Temperature Accessories 7001 Thermocouple Mini-Plug Kit (11 types) For use with: 700, 720 or 740 Series Process Calibrators, 714 Thermocouple. Description: A kit of 10 mini-plug connectors: Type J (black), one Type K (yellow), one Type T (blue), one Type E (purple), one Type R/S (green), one Type B or Cu (white), one Type L (J-DIN) (blue), one Type U (T-DIN) (brown), one Type C (red), one Type N (orange), one 7002 Thermocouple Mini-Plug Kit Type J, K, T, E, R/S For use with: 700, 720 or 740 Series Process Calibrators, 714 Thermocouple. Description: A kit of seven mini-plug connectors: Type J (black), two Type K (yellow), two Type T (blue), one Type E (purple), one Type R/S (green), one 80T-IR Non-Contact Infrared Temperature Probes For quick, non-contact temperature measurement in less than one second Instantly measures temperatures from -18 to 260 C (0 to 500 F) Highly repeatable readings displayed in C or F Optical resolution 4:1 Output 1m/ C or 1m/ F (switch selectable) 80T-IR/E Extended Range, Non-Contact Infrared Temperature Probe Special version of the 80T-IR: Extended range: 0 to 1,000 F Measures F only (no C) 80TK Thermocouple Module Converts multimeters with a m range into digital thermometers. Converts K-type thermocouple signals into m output. Connects to DMM via standard bannana plugs Switch selectable C or F Range: -50 to 1000 C (-58 to 1832 F) 8 Corporation Temperature Calibration 80PK-IR Infrared Temperature Probe Compatible with 714, 724, 725, 74X, 50 Series thermometers, 16 and 89 I DMMs, this probe measures the temperature of objects that can t be touched. Measurement range: -18 to 260 C (0 to 500 F) 80PK-1 and 80PJ-1 General Purpose Bead Probes Basic, inexpensive thermocouple. Good accuracy and fast response. (Not suitable for liquid immersion.) 80PK-1 for K-type thermometers; 80PJ-1 works for J-Type thermometers Measurement range: -40 to 260 C (-40 to 500 F) 80PK-2A K-Type Immersion Probe General-purpose probe including liquids and gels. Measurement range: -40 to 982 C (-40 to 1800 F) 80PK-3A K-Type Flat Surface Probe Measure the temperature of flat or slightly convex surfaces, such as hot rollers and plates. Exposed junction for direct contact with surface Measurement range: 0 to 260 C (32 to 500 F) 80PK-4A K-Type Air Probe For air and non-caustic gas applications. Probe of 304 stainless steel with perforated baffle around the bead Measurement range: -40 to 816 C (-40 to 1500 F) 80PK-5A and 80PT-5A Piercing Probes Designed for foods, liquids and gels. Probe made of 304 stainless steel 80PK-5A is compatible with K-Type instruments; 80PT-5A is designed for use with T-Type thermometers Measurement range: -40 to 260 C (-40 to 500 F) 80PK-6A K-type Exposed Junction Probe Use both as a surface probe and for insertion into air and non-corrosive gases. Probe made of 304 stainless steel Measurement range: -40 to 816 C (-40 to 1500 F) 80PK-7 K-Type Industrial / Heavy Duty Surface-Probe For flat or slightly curved surfaces. Exposed junction allows direct contact with the surface being measured Rugged design for extended service life Measurement range: -127 to 600 C (-196 to 1112 F) 80PK-8 K-Type Probe Pipe Clamp Temperature Probe Designed for pipes from 6.4 mm (1/4") diameter to 34.9 mm (1-3/8") diameter. Measurement range: -29 to 149 C (-20 to 300 F) 80PK-9 and 80PJ-9 General Purpose Probes Use as surface probe and for insertion into air and non-caustic gases. Probe constructed of 304 stainless steel 80PK-9 is compatible with K-type thermometers; 80PJ-9 operates with J-Type Measurement range: -40 to 260 C (-40 to 500 F) 80PK-EXT, 80PJ-EXT and 80PT-EXT Extension Wire Kits For extending and repairing J, K or T-type thermocouple wires. Kit includes 3 meters of thermocouple wire and 1 pair of male/ female mini-connectors Maximum continuous exposure temperature: 260 C (500 F). Keeping your world up and running. Corporation PO Box 9090, Everett, WA USA 98206 Europe B.. PO Box 1186, 5602 BD Eindhoven, The Netherlands For more information call: In the U.S.A. (800) 443-5853 or Fax (425) 446-5116 In Europe/M-East/Africa (31 40) 2 675 200 or Fax (31 40) 2 675 222 In Canada (800) 36-FLUKE or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www.fluke.com/ 2005 Corporation. All rights reserved. Printed in U.S.A. 10/2005 1560369 A-US-N Rev E