Thermal Management for LED Applications

Similar documents
Boundary Condition Dependency

Introduction to Heat and Mass Transfer. Week 7

Crazy Idea: Let s Make Circuit Boards out of FR-4! Testing the Performance of PTH and Copper Pour in Lieu of Metal Core PCBs in LED Applications

Thermal Interface Material Performance Measurement

Technical Notes. Introduction. PCB (printed circuit board) Design. Issue 1 January 2010

qxbxg. That is, the heat rate within the object is everywhere constant. From Fourier s

Law of Heat Transfer

/qirt The influence of air humidity on effectiveness of heat sink work. by M. Kopeć*, R. Olbrycht*

EVERLIGHT ELECTRONICS CO.,LTD. Technical Data Sheet High Power LED 1W (Preliminary)

3. LED THERMAL. a) b) 3.1. Introduction Heat transfer introduction LED ACADEMY/LED THERMAL

Unit B-4: List of Subjects

Design Guidelines for SFT Chipsets Assembly

HEAT TRANSFER THERMAL MANAGEMENT OF ELECTRONICS YOUNES SHABANY. C\ CRC Press W / Taylor Si Francis Group Boca Raton London New York

PROBLEM 1.2 ( ) 25 C 15 C dx L 0.30 m Ambient air temperature, T2 (C)

LedEngin, Inc. High Luminous Efficacy White Power LedFlex Emitter LZ4-00CW15. Key Features. Typical Applications. Description

ELEC9712 High Voltage Systems. 1.2 Heat transfer from electrical equipment

The Increasing Importance of the Thermal Management for Modern Electronic Packages B. Psota 1, I. Szendiuch 1

Thermal Unit Operation (ChEg3113)

University of Rome Tor Vergata

Thermal Modeling of Power Devices in a Surface Mount Configuration

Simple Analytical Calculations for

Heat Transfer: Physical Origins and Rate Equations. Chapter One Sections 1.1 and 1.2

Thermal experimental & simulation investigations on new lead frame based LED packages.

FYS4260/FYS9260: Microsystems and Electronics Packaging and Interconnect. Thermal Management

TeraLED. Thermal and Radiometric Characterization of LEDs. Technical Specification.

Brighter and Cooler. 95CRI Luna 200. Best Lumen / Watt LED Flip Chip COB Module

Principles of Food and Bioprocess Engineering (FS 231) Problems on Heat Transfer

1 One-Dimensional, Steady-State Conduction

Thermal Management of SMT LED Application Note

Two-Dimensional Numerical Investigation on Applicability of 45 Heat Spreading Angle

Thermal Management of Golden DRAGON LED Application Note

Phase Control Thyristor Type SKT552/16E

EVERLIGHT ELECTRONICS CO.,LTD.

Physics for Scientists & Engineers 2

Lecture 4: Classical Illustrations of Macroscopic Thermal Effects. Heat capacity of solids & liquids. Thermal conductivity

Electrical Power Cables Part 2 Cable Rating Calculations

Write Down Your NAME. Circle Your DIVISION. Div. 1 Div. 2 Div. 3 Div.4 8:30 am 9:30 pm 12:30 pm 3:30 pm Han Xu Ruan Pan

Component & Board Level Cooling.

Experiment 1. Measurement of Thermal Conductivity of a Metal (Brass) Bar

Introduction to Heat and Mass Transfer. Week 9

Examination Heat Transfer

Datasheet HeadLamp Module Series Version 0.6

Introduction to Heat and Mass Transfer. Week 5

WESTCODE. An IXYS Company. Date:- 10 Oct, Data Sheet Issue:- 1

IDB30E120. Fast Switching Emitter Controlled Diode. Product Summary V RRM 1200 V I F 30 A V F 1.65 V T jmax 150 C

LUXEON Rebel. power light source. Introduction. LUXEON Rebel Technology Leadership. Technical Datasheet DS56

Optimization of Heat Spreader. A thesis presented to. the faculty of. In partial fulfillment. of the requirements for the degree.

Lecture 36: Temperatue Measurements

IDB30E60. Fast Switching EmCon Diode. Product Summary V RRM 600 V I F 30 A V F 1.5 V T jmax 175 C

Thermal Analysis. with SolidWorks Simulation 2013 SDC. Paul M. Kurowski. Better Textbooks. Lower Prices.

As strong as the weakest link:

solid state LED LED LED LED LED LED Light Emitting Diode: LED LED module Self - ballasted LED module Integral LED module

Introduction of Heat Transfer. Prepared by: Nimesh Gajjar GIT-MED

COVENANT UNIVERSITY NIGERIA TUTORIAL KIT OMEGA SEMESTER PROGRAMME: MECHANICAL ENGINEERING

LUXEON Rebel. Direct Color Portfolio

Chapter 10: Steady Heat Conduction

Thermal Systems. What and How? Physical Mechanisms and Rate Equations Conservation of Energy Requirement Control Volume Surface Energy Balance

UNIVERSITY OF BOLTON SCHOOL OF ENGINEERING BENG (HONS) ELECTRICAL & ELECTRONICS ENGINEERING EXAMINATION SEMESTER /2018

CHAPTER 6 THERMAL DESIGN CONSIDERATIONS. page. Introduction 6-2. Thermal resistance 6-2. Junction temperature 6-2. Factors affecting R th(j-a) 6-2

Phase Control Thyristor Types N1467NC200 to N1467NC260

1. Nusselt number and Biot number are computed in a similar manner (=hd/k). What are the differences between them? When and why are each of them used?

Normalized Transient Thermal Impedance (Z th ) Using T C Reference Point Under Chip For 600V and 1200V A, NF, NFH and S-Series IGBT Modules

Thermal Sensors and Actuators

Rectifier Diode Types W0507YH360 to W0507YH450 Previous Type No.: SW36-45HXC270

UNIVERSITY OF WATERLOO. ECE 309 Thermodynamics and Heat Transfer. Final Examination Spring 1997

ENSC 388. Assignment #8

Surge non repetitive forward current I FSM 78 I FRM 47. P tot Operating and storage temperature T j, T stg

S.E. (Chemical) (Second Semester) EXAMINATION, 2012 HEAT TRANSFER (2008 PATTERN) Time : Three Hours Maximum Marks : 100

PHP/PHD3055E. TrenchMOS standard level FET. Product availability: PHP3055E in SOT78 (TO-220AB) PHD3055E in SOT428 (D-PAK).

Thermal testing of LEDs: emerging standards

Maximum Ratings Maximum Ratings, at T j = 25 C, unless otherwise specified Parameter Symbol Value Unit

Heat Tracing Basics. By: Homi R. Mullan 1

TeraLED. Thermal and Radiometric Characterization of LEDs. Technical Specification.

Performance of Light Emitting Diode on Surface Machined Heat Sink

Lecture 4: Losses and Heat Transfer

Dr. Michael Müller. Thermal Management for LED applications

SIPMOS Power-Transistor

( ) PROBLEM C 10 C 1 L m 1 50 C m K W. , the inner surface temperature is. 30 W m K

11. Advanced Radiation

Calculation and Characteristic Research of Temperature Rise for Motor Temperature Field

How thermal management affects your product and business

Coolant. Circuits Chip

PHYSICAL MECHANISM OF NATURAL CONVECTION

Thermal Analysis with SOLIDWORKS Simulation 2015 and Flow Simulation 2015

AN An Analysis for Power Dissipation of LDO Application with High Power. Hawk Chen. Thermal topology of LDO: Introduction:

ELECTRICAL AND THERMAL DESIGN OF UMBILICAL CABLE

The Meaning and Significance of Heat Transfer Coefficient. Alan Mueller, Chief Technology Officer

Direct Currents. We will now start to consider charges that are moving through a circuit, currents. Sunday, February 16, 2014

OCEAN/ESS 410. Class 3. Understanding Conductive Cooling: A Thought Experiment. Write your answers on the exercise sheet

10 23, 24 21, 22 19, , 14

Circle one: School of Mechanical Engineering Purdue University ME315 Heat and Mass Transfer. Exam #1. February 20, 2014

Phase Control Thyristor Types N1075LN180

Heat Sinks and Component Temperature Control

Super Bright LEDs, Inc.

Thermal Characterization of Packaged RFIC, Modeled vs. Measured Junction to Ambient Thermal Resistance

MECH 375, Heat Transfer Handout #5: Unsteady Conduction

Integrated Circuits Thermal Test Method Environment Conditions - Natural Convection (Still Air)

Phase Control Thyristor Types N1588NC200 to N1588NC260

Conjugate heat transfer from an electronic module package cooled by air in a rectangular duct

SIPMOS Small-Signal-Transistor

Transcription:

Thermal Management for LED Applications What is the role of the PCB? http://saturnelectronics.com/thermal_pcb_design_led_signup.htm Presented by Clemens Lasance Clemens is a former Principal Scientist Emeritus with Philips Research, the Netherlands, with a 30 year + focus on thermal management of electronic systems. He is now a consultant for Somelikeit Cool, contact info: lasance@onsnet.nu

Motivation Providing the right information the first time The goal is to provide the LED application engineer with the right information to select the most optimal MCPCB from a thermal point of view. Thus, ensuring the best decision is made for a specific application in regards to thermal performance and cost.

Main Goal of Thermal Management The Calculation of application-specific junction temperatures Reasons / Key Issues Lifetime Color point Efficiency All these key issues are significantly dependent on the junction temperature.

Basics of Heat Transfer Fundamentals of Critical Temperature Calculation Determining critical temperatures is contingent upon a critical understanding of: The electrothermal analogue Thermal conductivity k Heat transfer coefficient h Thermal resistance R th

Electro-Thermal Analogue?T = q * R th?v = I * R Temperature drop ( C) Voltage drop (V) Power dissipation (W) Current (A) Heat flux (W/m 2 ) Current density (A/m 2 ) Thermal resistance (K/W) Resistance (Ohm)

Electro-Thermal Analogue A heat transfer path can be described by an electrical network T source q R th T ambient?t = T source -T ambient R th (K/W) = thermal resistance

Series Circuit Example for two resistances in series T intermediate T source R 1 R 2 q T ambient DT = T source - T ambient = q * R total R total = R 1 + R 2

Consequence of Series Circuit Often only the largest R is relevant! T source T R intermediate 1 R 2 q T ambient Designer s job: find the largest resistance!

Thermal Conductivity: Fourier s Experiment (1822) Cross Sectional Area A Heat insulation hot Heat flow q cold Heated block L Water cooled block Result of Fourier s experiment: q ~?T = T hot T cold q ~ A = cross-sectional area q ~ L -1 q = k A T L The proportionality constant k is called the thermal conductivity

Typical Thermal Conductivity Values

The Heat Transfer Coefficient h The heat transfer from a solid wall into a fluid (air, water) is called convection, and to first order this heat transfer is proportional to the area and the temperature difference between the wall and the fluid: q = h A T The proportionality constant h is called the heat transfer coefficient Typical values: Natural convection: 10 W/m 2 K Forced convection: 50 W/m 2 K

Practice Suppose a Designer needs 5W to reach a required light output What procedure is most optimal? Information required for first order guess: Maximum junction temperature: e.g. 120 C Maximum ambient temperature: e.g. 40 C q = An estimation of all thermal resistances in the total heat transfer path T R th total

Practice (2) Next steps Check if required power is manageable by suitable heat sinks & convection Check which thermal resistances are dominant Then focus on them to reduce the total thermal resistance Final step should always be a detailed analysis Recall that often we don t talk one-dimensional heat transfer but heat spreading, which is a rather complicated issue For more information please see Heat Spreading, Not a Trivial Problem in the May 2008 issue of ElectronicsCooling

Practical Example q = k A T L R th = L k A q = h A T R th = 1 h A Relevant thermal resistances, assume 1 cm 2 PCB K/W R th -LED 16 Luxeon Rebel R th -MCPCB 0.5 t = 100 µm, k = 2 W/mK R th -TIM 1 t = 100 µm, k = 1 W/mK R th -heatsink 50 A = 20 cm 2, h = 10 W/m 2 K R th -heatsink 2 A = 100 cm 2, h = 50 W/m 2 K R th -heatsink 1 A = 1 cm 2, h = 10000 W/m 2 K

Practical Example We need 5W for our light output Can we find a suitable heat sink? We have: T junction = 120 C T ambient = 40 C R th -LED + R th -MCPCB + R th -TIM = 17.5 K/W; R th -heatsink =? Can we dissipate 5W? No way: q = 80 / (17.5 + R th -heatsink) q = T R th total Conclusion: Even with an ideal heat sink (R th -heatsink = 0) we cannot dissipate the required 5W. In this case we need an LED with less thermal resistance.

Practical Example We need 1W for our light output We have again: T junction = 120 C T ambient = 40 C R th -LED + R th -MCPCB + R th -TIM = 17.5 K/W; R th -heatsink =? Which heat sink is OK? q = 80 / (17.5 + R th -heatsink) ; R th -heatsink = 62.5 K/W q = T We found earlier: A=20 cm 2, h=10 W/m 2 K R th -heatsink = 50 K/W R th total Conclusion: We can use a simple heat sink with natural convection.

Practical Example Conclusion Thermal resistance of the MCPCB does not play any role In our first case, the LED thermal resistance was dominant; while in the last case, the convective resistance was dominant. Hence, from a thermal point only, you can choose MCPCBs with a much lower thermal performance and, hence, lower cost. The thermal performance of the PCB is relevant only for very high heat flux cases (e.g. liquid cooling) and for top-of-the-bill LEDs.

Nomenclature The confusing situation regarding thermal impedance Fact: Electrical impedance is historically reserved to describe time-dependent electrical resistance. In the limit of steady state, thermal impedance equals thermal resistance hence, units should be the same! Hence, Thermal impedance, as used by U.S. vendors, violates the electro-thermal analogy, because: Unit does not correspond (K/W vs. m 2 K/W) Definition does not correspond (time-dependent vs. steady state) Is this a problem? Yes, because time-dependent (dynamic) test methods will be increasingly used, one output of which is the correct thermal impedance. Proposal: Use thermal resistance per unit area, or unit R th.