Model Order Reduction of Interval Systems Using Mihailov Criterion and Cauer Second Form

Similar documents
Model Order Reduction of Interval Systems using Mihailov Criterion and Factor Division Method

TWO- PHASE APPROACH TO DESIGN ROBUST CONTROLLER FOR UNCERTAIN INTERVAL SYSTEM USING GENETIC ALGORITHM

Function Operations and Composition of Functions. Unit 1 Lesson 6

Stability Analysis of Nonlinear Systems with Transportation Lag

FUZZY SWING-UP AND STABILIZATION OF REAL INVERTED PENDULUM USING SINGLE RULEBASE

Section 1.3 Review of Complex Numbers

A MATLAB Toolbox for Teaching Model Order Reduction Techniques

Identification of Dominant and Non-Dominant States of Large Scale Discrete-Time Linear Systems and its Applications to Reduced Order Models

Sect Complex Numbers

Degree of a polynomial

Chemical Process Dynamics and Control. Aisha Osman Mohamed Ahmed Department of Chemical Engineering Faculty of Engineering, Red Sea University

Derivation of Robust Stability Ranges for Disconnected Region with Multiple Parameters

STABILITY ANALYSIS. Asystemmaybe stable, neutrallyormarginallystable, or unstable. This can be illustrated using cones: Stable Neutral Unstable

ECE317 : Feedback and Control

Control Systems Engineering ( Chapter 8. Root Locus Techniques ) Prof. Kwang-Chun Ho Tel: Fax:

Section 3.6 Complex Zeros

Applications of CAS to analyze the step response of a system with parameters

HANDOUT E.22 - EXAMPLES ON STABILITY ANALYSIS

Professor Fearing EE C128 / ME C134 Problem Set 4 Solution Fall 2010 Jansen Sheng and Wenjie Chen, UC Berkeley. control input. error Controller D(s)

H-infinity Model Reference Controller Design for Magnetic Levitation System

CHAPTER # 9 ROOT LOCUS ANALYSES

Chapter 2 Polynomial and Rational Functions

ECE317 : Feedback and Control

Module 07 Control Systems Design & Analysis via Root-Locus Method

State will have dimension 5. One possible choice is given by y and its derivatives up to y (4)

CompensatorTuning for Didturbance Rejection Associated with Delayed Double Integrating Processes, Part II: Feedback Lag-lead First-order Compensator

CONTROL SYSTEMS LECTURE NOTES B.TECH (II YEAR II SEM) ( ) Prepared by: Mrs.P.ANITHA, Associate Professor Mr.V.KIRAN KUMAR, Assistant Professor

DOA Estimation of Uncorrelated and Coherent Signals in Multipath Environment Using ULA Antennas

A Generalized Reverse Jacket Transform

Robust Tuning of Power System Stabilizers Using Coefficient Diagram Method

Remember that : Definition :

Independent Control of Speed and Torque in a Vector Controlled Induction Motor Drive using Predictive Current Controller and SVPWM

The Selection of Weighting Functions For Linear Arrays Using Different Techniques

STABILITY OF CLOSED-LOOP CONTOL SYSTEMS

Curriculum Map Grade 8 Math

Lecture 4 Classical Control Overview II. Dr. Radhakant Padhi Asst. Professor Dept. of Aerospace Engineering Indian Institute of Science - Bangalore

Vibration Suppression of a 2-Mass Drive System with Multiple Feedbacks

Software Engineering/Mechatronics 3DX4. Slides 6: Stability

Software Engineering 3DX3. Slides 8: Root Locus Techniques

Stability of Feedback Control Systems: Absolute and Relative

CERTAIN ALGEBRAIC TESTS FOR ANALYZING APERIODIC AND RELATIVE STABILITY IN LINEAR DISCRETE SYSTEMS

Lyapunov Stability of Linear Predictor Feedback for Distributed Input Delays

Fairfield Public Schools

QUANTITATIVE L P STABILITY ANALYSIS OF A CLASS OF LINEAR TIME-VARYING FEEDBACK SYSTEMS

Genetic Algorithm for Solving the Economic Load Dispatch

Outline. Control systems. Lecture-4 Stability. V. Sankaranarayanan. V. Sankaranarayanan Control system

MA 102 (Multivariable Calculus)

Methods for analysis and control of dynamical systems Lecture 4: The root locus design method

Some special cases

Warm-Up. Simplify the following terms:

Svoboda-Tung Division With No Compensation

Weighted balanced realization and model reduction for nonlinear systems

I What is root locus. I System analysis via root locus. I How to plot root locus. Root locus (RL) I Uses the poles and zeros of the OL TF

A Learning Progression for Complex Numbers

OPTIMAL DESIGN AND ANALYSIS OF A CHEMICAL PROCESS CONTROL SYSTEM

Polynomial and Rational Functions. Copyright Cengage Learning. All rights reserved.

CHAPTER 3: Quadratic Functions and Equations; Inequalities

Design of Stable IIR filters with prescribed flatness and approximately linear phase

Velammal Engineering College Department of Production Engineering

Lecture 3: The Root Locus Method

Direct Torque Control of Three Phase Induction Motor FED with Three Leg Inverter Using Proportional Controller

ONE-DIMENSIONAL (1-D) two-channel FIR perfect-reconstruction

Modified SVPWM Algorithm for 3-Level Inverter Fed DTC Induction Motor Drive

Research Article Weighted Measurement Fusion White Noise Deconvolution Filter with Correlated Noise for Multisensor Stochastic Systems

Smooth Profile Generation for a Tile Printing Machine

What is the purpose of this document? What is in the document? How do I send Feedback?

Performance Analysis of Coarray-Based MUSIC and the Cramér-Rao Bound

CURRICULUM VITAE PROF. KAZA SOMASEKHARA RAO,

Alireza Mousavi Brunel University

ECE 345 / ME 380 Introduction to Control Systems Lecture Notes 8

Delay-Dependent Stability Criteria for Linear Systems with Multiple Time Delays

If you need more room, use the backs of the pages and indicate that you have done so.

2.004 Dynamics and Control II Spring 2008

H State-Feedback Controller Design for Discrete-Time Fuzzy Systems Using Fuzzy Weighting-Dependent Lyapunov Functions

EE Control Systems LECTURE 9

Addition of QSD intermediat e carry and sum. Carry/Sum Generation. Fig:1 Block Diagram of QSD Addition

Part 2 Number and Quantity

NPTEL web course on Complex Analysis. A. Swaminathan I.I.T. Roorkee, India. and. V.K. Katiyar I.I.T. Roorkee, India

MATH4406 (Control Theory) Unit 1: Introduction Prepared by Yoni Nazarathy, July 21, 2012

A DESIGN METHOD FOR SIMPLE REPETITIVE CONTROLLERS WITH SPECIFIED INPUT-OUTPUT CHARACTERISTIC

Curriculum Vitae. Previous Work Experience. Eaton Technologies Pvt. Ltd., Pune, India Division. Tata Motors Pvt. Ltd., Pune, India Division

Passivity Indices for Symmetrically Interconnected Distributed Systems

Observer-based sampled-data controller of linear system for the wave energy converter

AN ENHANCED CRYPTOGRAPHIC SUBSTITUTION METHOD FOR INFORMATION SECURITY

Applicatin of the α-approximation for Discretization of Analogue Systems

Root locus Analysis. P.S. Gandhi Mechanical Engineering IIT Bombay. Acknowledgements: Mr Chaitanya, SYSCON 07

MASSACHUSETTS INSTITUTE OF TECHNOLOGY Department of Electrical Engineering and Computer Science : Dynamic Systems Spring 2011

LMI Based Model Order Reduction Considering the Minimum Phase Characteristic of the System

Outline. Classical Control. Lecture 1

Analysis of SISO Control Loops

A HIGH-SPEED PROCESSOR FOR RECTANGULAR-TO-POLAR CONVERSION WITH APPLICATIONS IN DIGITAL COMMUNICATIONS *

UNCERTAINTY MODELING VIA FREQUENCY DOMAIN MODEL VALIDATION

Teaching Electromagnetic Fields with Computer Visualization

List of Publications:

Polynomial and Synthetic Division

Signal Correction of Load Cell Output Using Adaptive Method

CONSTRUCTION OF RECTANGULAR PBIB DESIGNS

7.4 STEP BY STEP PROCEDURE TO DRAW THE ROOT LOCUS DIAGRAM

PERIODIC signals are commonly experienced in industrial

Mathematics Standards for High School Financial Algebra A and Financial Algebra B

Transcription:

Model Order Reduction of Interval Systems Using Mihailov Criterion and Cauer Second Form D. Kranthi Kumar Research Scholar S. K. Nagar Professor J. P. Tiwari Professor ABSTRACT This paper presents a new mixed method for reducing the large scale interval systems using the Mihailov Criterion and Cauer second form. The reduced order model of denominator is determined by using Mihailov Criterion and numerator coefficients are obtained by using Cauer second form. We show that the mixed method is simple and guarantees the stability of the reduced model if the original system is stable. A numerical examples are illustrated and verified its stability. Keywords Mihailov Criterion, Cauer second form, Reduced order, Stability, Mixed method. 1. INTRODUCTION Model order reduction of interval systems has been considered by several researchers. The technique of Routh approximation [1] based on direct truncation guarantees the stability of reduced order model. γ-δ Routh approximation [2] evaluated for order reduction. Hwang [3] has proposed comments on the computation aspects of interval Routh approximation. Sastry et al [4] has proposed γ table approximation to decreasing complexity of the γ-δ Routh algorithm. Yuri Dolgin suggested another generalization of direct routh table truncation method [5] for interval systems. He proved that the existing generalization of direct truncation of Routh fails to produce a stable system. But S-F.Yang commented [6] on Yuri Dolgin s method that it cannot guarantee the stability of lower order interval systems. To overcome all these problems Yuri Dolgin added some conditions [7] for getting the stability of reduced order through Routh approximation. To improve the effectiveness of model order reduction many mixed methods are proposed recently [8-11]. In the present paper, model order reduction of interval systems is carried out by using mixed method. The denominator of the reduced model is obtained by Mihailov Criterion and the numerator is obtained by Cauer second form. Thus the stability of the reduced order model is guaranteed, if the higher order interval system is asymptotically stable. The brief outline of this paper is as follows: Section 2 contains problem statement. Section 3 contains proposed method. Error analysis done in section 4. Numerical examples are presented in section 5 and t conclusion in section 6. 2. PROBLEM STATEMENT Let the transfer function of a higher order interval systems be (1) G n s [p 0, p 0 ] p 1, p 1 s p n 1,p n 1 sn 1 q 0,q 0 q 1,q 1 s. q n,q n s n N (s) D (s) where [p i, p i ] for i 0 to n-1 and [q i, q i ] for i 0 to n are known as scalar constants. The reduced order model of a transfer function be considered as R r s u 0,u 0 u 1,u 1 s [u r1,u r1 ]s r1 N v 0,v 0 v 1,v 1 s v r,v r s r s r D r s (2) where [u j, u j ] for j 0 to r-1and [v j, v j ] for j 0 to r are known as scalar constants. The rules of the interval arithmetic have been defined in [12], as follows. Let [e, f] and [g, h] be two intervals. Addition: [e, f] [g, h] [e g, f h] Subtraction: [e, f] [g, h] [e h, f g] Multiplication: [e, f] [g, h] [Min (eg, eh, fg, fh), Max (eg, eh, fg, fh)] Division: e,f g, e, f 1, 1 g 3. PROPOSED METHOD The proposed method consists of the following steps for obtaining reduced order model. Step 1: Determination of the denominator polynomial of the k t order reduced model: Substituting s jω in D(s) and separating the denominator into real and imaginary parts, D (jw) [c 11, c 11 ] c 12, c 12 jω. c 1,n1, c 1,n1 (jω) n 17

c 11, c 11 c 13, c 13 ] ω 2. jω ( c 12, c 12 ω, c 14 ω 2 ) c 14 ξ (ω) jω η(ω) (3) Step 2: Determination of the numerator coefficients of the k t order reduced model by using Cauer second form: Coefficient values from Cauer second form [ p, p ] (p 1, 2, 3.... k) are evaluated by forming Routh array as where ω is the angular frequency, rad/sec. ξ (ω) 0 and ɳ (ω) 0, the frequencies which are intersecting ω 0 0, ± ω 1, ω 1,. ±[ ω n1, ω n1 ] are obtained, where [ω 1, ω 1 ] [ω 2, ω 2 ].. [ω n1, ω n 1 ]. Similarly substituting s jω in D k s, then obtains D k jω φ ω jω ψ (ω) (4) 1, 1 2, 2 c 11, c 11 c 21, c 21 c 21, c 21 c 31, c 31 c 11, c 11 c 12, c 12. c 21, c 21 c 22, c 22 c 21, c 21 c 22, c 22. c 31, c 31 c 32, c 32 where φ ω [d 11, d 11 ] d 13,d 13 ω 2. and ψ ω [d 12, d 12 ] d 14, d 14 ω 2. Put φ (ω) 0 and ψ (ω) 0, then we get k number of roots and it must be positive and real and alternately distributed along the w axis. The first k numbers of frequencies are 0, ω 1, ω 1, ω 2, ω 2,..., [ω k1, ω k1 ] are kept unchanged and the roots of φ (ω) 0 and ψ (ω) 0. Therefore, φ ω λ 1, λ 1 ω 2 2 2 ω 1, ω 1 ω 2 ω 2 2 3, ω 3 ω 2 ω 2 2 5, ω 5 (5) ψ ω λ 2, λ 2 ω 2 2 2 ω 2, ω 2 ω 2 ω 2 2 4, ω 4 ω 2 ω 2 2 6, ω 6 (6) For finding the coefficient values of [λ 1, λ 1 ] and [λ 2, λ 2 ] are calculated from ξ (0) φ (0) and ɳ ω 1, ω 1 ψ ω 1, ω 1. keeping these values of [λ 1, λ 1 ] and [λ 2, λ 2 ] in equations (5) and (6), respectively, φ (ω) and ψ (ω) are obtained and D k (jω) is obtained as D k jω φ ω jω ψ (ω) (7) Now replace jω by s, then the k t order reduced denominator D k (s) is obtained as D k (jω) [d 11, d 11 ] d 12, d 12 s. d 1,k1, d 1,k1 (s) k (8) 3, 3 c 31, c 31 c 41, c 41 c 31, c 31 c 32, c 32. c 41, c 41 c 42, c 42.................. (9) The first two rows are copied from the original system numerator and denominator coefficients and rest of the elements are calculated by using well known Routh algorithm. [c ij, c ij ] c (i2,j 1), c (i2,j 1) (10) i2 where i 3,4,..... and j 1,2,.... i, i (11) [c i,1,c i,1 ] [c (i1,1),c (i1,1), i2 [c (i1,j 1), c (i2,j 1) ] ] ; i 1,2,3, k The coefficient values of d i,j, d i,j (j 1,2,...(k1))] Of the equation (8) and Cauer quotients [ p, p ] (p 1. 2,... k) of the the equation (9) are matched for finding the coefficients of numerator of the reduced model R k (s). The inverse routh array is constructed as [d (i1,1), d (i1,1) ] [d i,1,d i,1 ] (12) i 1,2,...,k and k n [d (i1,j 1), d (i1,j1) (13) [ i, i ] ] ( d i,j 1,d i,j 1 [d (i2,j ) [ i, i ] where i 1. 2,...., (k-j) and j 1,2,...., (k-1),d (i2,j ) ] Using the above equations, the numerator coefficients of the reduced model are obtained and numerator is written as 18

N k s d 21, d 21 d 22, d 22 s [d 2k, d 2k ]s k1 (14) N 2 s 11.1949, 20.3706 s [14.1674, 16.9413] Step 7: The reduced order model R 2 (s) is given as 4. Error Analysis The integral square error (ISE) in between the transient responses of higher order system (HOS) and Lower order system (LOS) and is given by: R 2 s 11.1949,20.3706 s[14.1674,16.9413 ] 17..0011,18.0007 s 2 31.3826,33.6111 s[20.3061,21.7052 ] ISE [y(t) y 0 r (t)]² dt (15) where, y (t) and y r (t) are the unit step responses of original system G n s and reduced order system R k s. 5. Numerical Examples Example 1: Consider a third order system described by the transfer function [13] G 3 s 2,3 s 2 17.5,18.5 s[15,16] 2,3 s 3 17,18 s 2 35,36 s[20.5,21.5] (16) Step 1: Put s jω in the denominator D (s) D (jω) ([20.5, 21.5] [17, 18]ω 2 ) jω ([35, 36] [2, 3]ω 2 ) Step 2: The intersecting frequencies are [ω i, ω i ] 0, 1.0929, 1.0981, [3.4641, 4.1833] Step 3: Following the procedure given in section 3, the denominator of the second order model is taken as D 2 jω λ 1, λ 1 ω 2 1.0929, 1.9081 2 jω [λ 2, λ 2 ], Here λ 1, λ 1 17.0011, 18.0007 and λ 2, λ 2 [31.3826, 33.6111] Step 4: Substitute the values of [λ 1, λ 1 ] and [λ 2, λ 2 ] in step 3 and also substitute jω s. Fig. 1 : Step Response of original model and ROM Table 1. Comparison of Reduced Order Models Method of Order reduction ISE for lower limit errl Proposed Algorithm 0.0089 0.0113 G.V.S.S Sastry [3] 0.2256 0.0095 ISE for upper limit erru Hence, the denominator D(s) is given by D 2 s 17..0011, 18.0007 s 2 31.3826, 33.6111 s [20.3061, 21.7052] Step 5: Using the Cauer second form as described in the section 3, it is obtained [ 1, 1 ] [1.2812, 1.4333] [ 2, 2 ] [1.1046, 1.8859] [d 21, d 21 ] [14.1674, 16.9413] [d 22, d 22 ] [11.1949, 20.3706] are obtained. Step 6: Numerator of second order system is written as The step response of second order model is obtained by the proposed method and compared with second order model. Example 2: Consider a third order system described by the transfer function [16] G 3 s 1,1 s 2 3.3,6.5 s[2.7,10] 1,1 s 3 8.5,8.6 s 2 18,18.2 s[10.25,10.76] (17) Step 1: Put s jω in the denominator D (s) D(jω) ([10.25, 10.76] [8.5, 8.6]ω 2 ) jω([18, 18.2] [1, 1]ω 2 ) 19

Step 2: The intersecting frequencies are Table 2. Comparison of Reduced Order Models [ω i, ω i ] 0, 1.0981, 1.1185, [4.2426, 4.2661] Step 3: Following the procedure given in section 3, the denominator of the second order model is taken as Method of Order reduction ISE for lower limit errl ISE for upper limit erru D 2 jω λ 1, λ 1 ω 2 1.0929, 1.9081 2 jω [λ 2, λ 2 ], Here [λ 1, λ 1 ] 8.1934, 8.9235 and λ 2,λ 2 [16.749, 16.9942] Step 4: Substitute the values of [λ 1, λ 1 ] and [λ 2, λ 2 ] in step 3 and also substitute jω s. Hence, the denominator D(s) is given by D 2 s 8.1934, 8.9235 s 2 16.749, 16.9942 s 9.8796, 11.1633 Step 5: Using the Cauer second form as described in the section 3, it is obtained [ 1, 1 ] [1.025, 3.9852] [ 2, 2 ] [1.2652, 0.6749] [d 21, d 21 ] [2.4791, 10.8910] [d 22, d 22 ] [0.1535, 24.9778] are obtained. Step 6: Numerator of order system is written as N 2 s 0.1535, 24.9778 s [2.4791, 10.8910] Step 7: The reduced second order model R 2 (s) is given as R 2 s 0.1535,24.9778 s 2.4791,10.8910 8.1934,8.9235 s 2 16.749,16.9942 s 9.8796,11.1633 The step response of second order model is obtained by the proposed method and compared with second order model Fig.2.Step Response of original model and ROM Proposed Algorithm 0.0264 1.0314 G.Saraswathi [8] 0.0034 0.0364 6. CONCLUSION In this paper Mihailov criterion and Cauer second form is employed for order reduction. The reduced model of denominator polynomial is obtained by using Mihailov criterion and the numerator is determined by cauer second form. The proposed method guarantees the stability of reduced model if the original system is stable. This proposed method is conceptually simple and comparable with other well known methods. Two examples are taken from the literature and compared with other methods by using ISE. 7. REFERENCES [1] B. Bandyopadhyay, O. Ismail, and R. Gorez, Routh Pade approximation for interval systems, IEEE Trans. Automat. Contr., pp. 2454 2456, Dec1994. [2] B. Bandyopadhyay.: γ-δ Routh approximations for interval systems, IEEE Trans. Autom. Control, pp. 1127-1130, 1997. [3] C. Hwang and S.-F. Yang, Comments on the computation of interval Routh approximants, IEEE Trans. Autom. Control, vol. 44, no. 9, pp.1782 1787, Sep. 1999. [4] G V K Sastry, G R Raja Rao and P M Rao. Large Scale Interval System Modelling Using Routh Approximants. Electronics Letters, vol 36, no 8, pp. 768. April 2000. [5] Y. Dolgin and E. Zeheb, On Routh-Pade model reduction of interval systems, IEEE Trans. Autom. Control, vol. 48, no. 9, pp. 1610 1612, Sep. 2003. [6] S. F. Yang, Comments on On Routh-Pade model reduction of interval systems, IEEE Trans. on Automatic Control, vol. 50, no. 2, pp.273-274, 2005. [7] Y. Dolgin, Author s Reply, IEEE Trans. Autom. Control, vol. 50, no. 2, pp. 274-275, Feb. 2005. [8] G.Saraswathi, A Mixed Method for Order Reduction of Interval Systems, International Conference on Intelligent and Advanced Systems, pp. 1042-1046, 2007. [9] Yan Zhe Penngfei Bi Zhiqiang Zhang and Liwei Niu, Improved algorithm of model order reduction of large scale internal system, The 6 th International Forum on strategic technology, pp:716-719, Aug 22-24, 2011. [10] D.Kranthi kumar, S. K. Nagar and J. P. Tiwari, Model Order Reduction of Interval Systems Using Mihailov Criterion and Routh Approximations, International journal of engineering science and technology, Vol. 3 No. 7, pp. 5593-5598, July 2011. 20

[11] D. Kranthi kumar, S. K. Nagar and J. P. Tiwari, Model Order Reduction of Interval Systems Using Mihailov Criterion and Factor Division Method, International journal of computer applications,volume 28 No.11, pp. 4-8, August 2011 [12] E.Hansen, Interval arithmetic in matrix computations, Part I, SIAM J. Numerical Anal., pp. 308-320, 1965. 8. BIOGRAPHIES D. Kranthi Kumar was born in Guntur, A.P, India in 1986. He received the degree of B.E from SIR. C. R. Reddy College of Engineering in 2008 and received the degree of M.Tech in Electrical Engineering from IT-BHU, Varanasi, in 2010 and presently pursuing Ph.D in Electrical Engineering at IT-BHU, Varanasi, India. He is life member in System Society of India (SSI) and student member in Institute of Engineers (Ireland). S. K. Nagar was born in Varanasi, India in 1955. He received the degrees of B.Tech and M.Tech from the Institute of Technology, Banaras Hindu University (IT-BHU), Varanasi, India In 1976 and 1978; and PhD in Electrical Engineering from University of Roorkee (IIT Roorkee), India in 1991. He is currently Professor in Electrical Engineering at IT-BHU, Varanasi, India. His main research includes digital control, model order reduction and discrete event systems. He has published many papers in national & International conferences & Journals. J. P. Tiwari was born in Deoria, U.P, India in 1947. He received the degrees of B.E. and M.E. from University of Roorkee, India in 1968 and 1971. Ph.D in Electrical Engineering from India in 1991. He is currently Professor, Head of the Department in Department of Electrical Engineering at IT-BHU, Varanasi, India. His main research includes Control systems, Robotics, Instrumentation, Control Systems, Adaptive control. He has published many papers in National & International conferences and journals. 21