Fabrication and characterization of grafted polymer electrode self modification with activated carbon

Similar documents
Electrochemical oxidation effect of ascorbic acid on mercury ions in blood sample using cyclic voltammetry

Voltammetric characterization of grafted polymer electrode self modification with carbon nanotubes (GPESMCNT)

Electrochemical characterization of the redox couple of Fe(III)/Fe(II) mediated by grafted polymer electrode

Nano Biomed Eng 2016; 8(1): doi: /nbe.v8i1.p9-15.

A Voltammetric Properties of Biopolymer Nano- Composites Based Polybutylene Succinate/Epoxidized Palm Oil

Nanoparticles of TiO 2 -ZnO Modified Polystyrene- Acrylonitrile Characterization Using Glassy Carbon Electrode

A Study of Electrochemical Behavior for Redox Current Peaks of Sodium Saccharin at Different Temperature Using Nano-Sensor

Electronic Supplementary Material (ESI) for Chemical Communications This journal is The Royal Society of Chemistry 2011

Electrochemical Characterization of Sky Honey Mediated by Glassy Carbon Electrode Modified with Carbon Nanotube

Voltammetry Detection of Ascorbic Acid at Glassy Carbon Electrode Modified by Single-Walled Carbon Nanotube/Zinc Oxide

Application Studies to Voltammetric Detection of Trace Hg (II) by Different Modified Solid Glassy Carbon Electrode

Voltammetric Study of the Redox Current Peaks of Pb(II) Mediated by GCE in Normal Saline

Supporting Information. Electropolymerization of aniline on nickel-based electrocatalysts substantially

Supporting Information. One-Pot Synthesis of Reduced Graphene

CHAPTER-5 CYCLIC VOLTAMETRIC STUDIES OF NOVEL INDOLE ANALOGUES PREPARED IN THE PRESENT STUDY

Cyclic Voltammetry. Fundamentals of cyclic voltammetry

Carbon nanotubes and conducting polymer composites

Goals. The laboratory instructor has already purged the solutions of dissolved. Purging the from these solutions prevents spurious

Electrochemical Interferences of Mn 2+ with Hg 2+, Cd 2+ and Cu 2+ at Different Modified GCE

Supporting Information

Voltammetry. Voltammetry and Polarograph. Chapter 23. Polarographic curves -- Voltammograms

Supplementary Materials

Supplementary Information. Seeding Approach to Noble Metal Decorated Conducting Polymer Nanofiber Network

Supplementary Information. For. A Universal Method for Preparing Functional ITO Electrodes with Ultrahigh Stability

Specific Determination of Hydrogen Peroxide With A Catalase Biosensor Based on Mercury Thin Film Electrodes

Homogeneous Electrochemical Assay for Protein Kinase Activity

Short Communication Electrochemical Polymerization of Methylene Blue on Glassy Carbon Electrode

Supporting Information

Electrochemical Sensors of Cyclic Voltammetry to Detect Cd(II) in Blood Medium

Chapter - 8. Summary and Conclusion

Solution Purging. Goals. 1. Purge both solutions with an inert gas (preferably N 2

Lecture 4. Conductance sensors. ChemFET. Electrochemical Impedance Spectroscopy. py Practical consideration for electrochemical biosensors.

Cyclic Voltammetry. Objective: To learn the basics of cyclic voltammetry with a well-behaved echem system

Supporting Information

Current based methods

Dr. Aoife Morrin. School of Chemical Sciences Dublin City University Ireland. The National Centre for Sensor Research

Supplementary Figure 1 a) Scheme of microfluidic device fabrication by photo and soft lithography,

[Supplementary Information] One-Pot Synthesis and Electrocatalytic Activity of Octapodal Au-Pd Nanoparticles

Nanomaterials and Chemistry Key Laboratory, Wenzhou University, Wenzhou, (P. R. China).

4. CV curve of GQD on platinum electrode S9

Synthesis and Characterization of Grafted Polystyrene with Acrylic Acid Using Gamma-Irradiation

Nitroxide polymer networks formed by Michael addition: on site-cured electrode-active organic coating

Electron Transfer Rates in DNA Films as a Function of Tether Length. T. Gregory Drummond, Michael G. Hill, and Jacqueline K.

Oxygen evolution reaction electrocatalyzed on a Fenton-treated gold surface. P. Esakki Karthik, C. Jeyabharathi and K. L. N.

Templated electrochemical fabrication of hollow. molybdenum sulfide micro and nanostructures. with catalytic properties for hydrogen production

Electrocrystallization of monolayer protected gold clusters: opening the door to quality, quantity and new structures

VI. EIS STUDIES LEAD NANOPOWDER

CYCLIC VOLTAMMETRIC STUDY OF Pb (II) IN DIFFERENT SODIUM SALTS AS SUPPORTING ELECTROLYTES

Carbon Quantum Dots/NiFe Layered Double Hydroxide. Composite as High Efficient Electrocatalyst for Water

Introduction to Cyclic Voltammetry Measurements *

Chapter 2. Materials and Methods

Electronic Supplementary Information for: 3D-Printed Plastic Components Tailored for Electrolysis

STUDY OF Zn (II) IN DIFFERENT SODIUM SALTS AS SUPPORTING ELECTROLYTES USING CYCLIC VOLTAMMETRIC TECHNIQUE

Wanzhen Li, Longhua Ding, Qiaohong Wang and Bin Su*

Nickel Phosphide-embedded Graphene as Counter Electrode for. Dye-sensitized Solar Cells **

Electronic Supplementary Information. for. Discrimination of dopamine from ascorbic acid and uric acid on thioglycolic. acid modified gold electrode

Fundamental molecular electrochemistry - potential sweep voltammetry

Electrochemical Oxidation of Paracetamol Mediated by MgB 2 Microparticles Modified Glassy Carbon Electrode

Supporting Information. High Wettable and Metallic NiFe-Phosphate/Phosphide Catalyst Synthesized by

Biotinyl moiety-selective polymer films with highly ordered macropores

Lithium-ion Batteries Based on Vertically-Aligned Carbon Nanotubes and Ionic Liquid

Electrochemistry and Detection of Organic and Biological Molecules Such as Catechol and Ascorbic Acid at Conducting Poly (2,2-bithiophene) Electrode

Voltammetric Comparison of the Electrochemical Oxidation of Toluene on Monolithic and Reticulated Glassy Carbon Electrodes in Aqueous Medium

Supplementary Figure S1. AFM image and height profile of GO. (a) AFM image

N-doped Carbon-Coated Cobalt Nanorod Arrays Supported on a Titanium. Mesh as Highly Active Electrocatalysts for Hydrogen Evolution Reaction

Sulaf Samir Ibrahem Master s Department of Physical Chemistry, Faculty of Science, Al-Baath University Homs, Syria

Johary Rivera (Chemistry - University of Puerto Rico, Río Piedras Campus)

Supporting Information

Single Catalyst Electrocatalytic Reduction of CO 2 in Water to H 2 :CO Syngas Mixtures with Water Oxidation to O 2

This material is based upon work supported by the National Science Foundation under Grant Number DUE

Supporting Information Inherent Electrochemistry and Charge Transfer Properties of Few-Layer Two Dimensional Ti 3 C 2 T x MXene

Study of Electrode Mechanism by Cyclic Voltammetry

Supporting Information

Unit 2 B Voltammetry and Polarography

A Robust and Highly Active Copper-Based Electrocatalyst. for Hydrogen Production at Low Overpotential in Neutral

State of São Paulo. Brasil. Localization. Santo André

Supplementary Information

Highly efficient hydrogen evolution of platinum via tuning the interfacial dissolved-gas concentration

A Sensitive Dissolved Oxygen Sensor Based on a Charge-Transfer Complex Modified Electrode

Synthese und elektrochemische Anwendungen von modifizierten Kohlenstoffnanoröhren

Supplementary Information. Carolyn Richmonds, Megan Witzke, Brandon Bartling, Seung Whan Lee, Jesse Wainright,

Supporting Information

Electronic Supplementary Information

One polymer for all: Benzotriazole Containing Donor-Acceptor Type Polymer as a Multi-Purpose Material

Preparation of Polythiophene Films Showing Optical Activity by Electrochemical Polymerisation in Cholesteric Liquid Crystal Containing Coumarine

Electronic Supplementary Information

Supporting Information

Fig. S1 The Structure of RuCE(Left) and RuCA (Right)

Three Dimensional Nano-assemblies of Noble Metal. Nanoparticles-Infinite Coordination Polymers as a Specific

Novel Supercapacitor Materials Including OLED emitters

Nickel Sulfides Freestanding Holey Films as Air-Breathing Electrodes for. Flexible Zn-Air Batteries

Solutions for Assignment-8

XANTHINE OXIDASE MODIFIED GLASSY CARBON PASTE ELECTRODES

An Ideal Electrode Material, 3D Surface-Microporous Graphene for Supercapacitors with Ultrahigh Areal Capacitance

sensors ISSN by MDPI

Chemically-Resolved Transient Collision Events of Single Electrocatalytic Nanoparticles. Zhihui Guo, Stephen J. Percival, and Bo Zhang*

Xiufang Chen, Jinshui Zhang, Xianzhi Fu, Markus Antonietti, and Xinchen Wang*

Supplementary Information. Unusual High Oxygen Reduction Performance in All-Carbon Electrocatalysts

Supporting Information

High-resolution on-chip supercapacitors with ultra-high scan rate ability

Transcription:

Int J Ind Chem (2016) 7:103 108 DOI 10.1007/s40090-015-0058-4 RESEARCH Fabrication and characterization of grafted polymer electrode self modification with activated carbon Muhammed Mizher Radhi 1 Received: 12 June 2015 / Accepted: 24 September 2015 / Published online: 18 November 2015 The Author(s) 2015. This article is published with open access at Springerlink.com Abstract A new grafted polymer electrode self modified with activated carbon (GPESMAC) was fabricated and electrochemical characterization by cyclic voltammetric analysis. The polystyrene was used as polymer grafted with acrylonitrile as a monomer and activated carbon as improvement material using gamma irradiation to produce a new copolymer. The redox process of K 3 Fe(CN) 6 during cyclic voltammetry was studied with the new working electrode (GPESMAC) by cyclic voltammetric analysis. The physical properties of these electrodes have high hardness, insolubility, and stability at different high temperatures. Also, the sensitivity under conditions of cyclic voltammetry is significantly dependent on different scan rate and concentrations. The GPESMAC was characterized by surface analytical methods including SEM and AFM. Interestingly, the redox reaction of Fe(III) solution using GPESMAC remained constant even after 15 cycles. It is therefore evident that the GPESMAC possesses some degree of stability. The potential use of the grafted polymer as a useful electrode material is therefore clearly evident. It is through the study of applications in quantitative and qualitative analysis proved that the conductivity of grafted polymer with activated carbon is highly efficient and stability compared with the commercial solid electrodes and modified by mechanical means or by evaporating the solvent, such as glassy carbon electrode. On the other hand an enhancement of redox current peaks and high detection limits effective species such as Fe(II)/Fe(III) was studied. & Muhammed Mizher Radhi mmradhi@yahoo.com 1 Health and Medical Technology College, Middle Technical University, Baghdad, Iraq Keywords Grafted polymer electrode self modified Activated carbon Redox couple Fe(III)/Fe(II) Electrocatalysis Cyclic voltammetry Introduction The process of modifying polymers with good conductive materials stirs the attention of the scientists in recent times. One of these methods is irradiation of grafting polymers and modified with conductive materials to be used for multiple purposes, especially in the field of conductors and semiconductors, as well as in electrochemistry [1 4]. A composite polymer membrane working electrode has been studied at cyclic voltammetric for famotidin and terthiophene determination of drug in pharmaceutical formulation. This composite film of polymer electrode showed good catalytic behavior, which includes a good current response [5, 6]. The modified electrode functionalized with polyacrylic acid (PAA) tethered to indium tin oxide (ITO) and covered with gold nanoparticle (ITO/PAA/Au) demonstrated switchable interfacial properties discriminating different ph. The switchable electrochemical and plasmonic process was characterized by cyclic voltammetry (CV), electrochemistry impedance spectroscopy (EIS), and localized surface plasmon resonance (LSPR) [7]. Grafted molecularly imprinted (MIP) polymer thin films onto Au electrodes was studied as good sensor in the presence of N,N 0 -methylenebis(acrylamide) to detection of hydroquinone [8]. Another study for using a molecularly imprinted polymer (MIP) as a recognition element in the development of a heparin sensor for real-time monitoring. An indium tin oxide (ITO) electrode grafted with a heparin-specific MIP was used

104 Int J Ind Chem (2016) 7:103 108 as a working electrode to perform cyclic voltammetry of ferrocyanide. The anodic current was found to be dependent on heparin concentration. Therefore, the MIP-grafted electrode is suitable for real-time monitoring of heparin in blood. The advantage of these method is that a very small volume of blood is needed, which is very important, especially when regular measurements are required [9]. The electrical connectivity of grafted polymer with pair of electrons located on the nitrogen atom within the structure of grafted polymer, and in addition to that the presence of high conductivity in a series of a activated carbon is one of the reasons used in the manufacture of electrodes operating polymeric high connectivity characteristic, which is mainly used in the analysis electrochemistry, especially in a cyclic voltammetry [4]. One of the syntheses of grafting polymers is electropolymerization of statistically exposed dithiobenzoate moieties served as a chain transfer agent for the polymerization of styrene on a matrix of an electrodeposited conjugated polymer. The polystyrene modified substrate was then used as the macro chain transfer agent for the synthesis of the second block of poly-tert-butyl acrylate on the surface. The polymerization from the surface was characterized by surface analytical methods including AFM, XPS, and contact angle measurements [10 14]. In this work, grafted polymer was modified with activated carbon to fabrication grafted polymer electrode self modified with activated carbon by gamma ray. The new grafted polymer electrode was electrochemically characterized in K 3 Fe(CN) 6 with KCl aqueous electrolyte by CV technique. Experimental Synthesis of grafted polymer modified with activated carbon (GP/AC) Polystyrene-acrylonitrile was grafted with activated carbon (AC) as an improvement material, using gamma-irradiation. The new grafted polymer modified with activated carbon indicated that the best grafting percentage ratio could be revealed when the concentration of the catalyst ferrous ammonium sulphate (FAS) is about 2 % and the monomer concentration is 90 %, at gamma ray dose 1.25 M rad [4]. Instrument and electroanalytical methods Electrochemical workstations of NuVant Systems Inc., USA (EZ stat series with potentiostat/glvanostat driven by electroanalytical measuring software) were connected to a PC computer in order to perform cyclic voltammetry (CV), chronoamperometry (CC), and chronoamperometry (CA). An Ag/AgCl (3 M NaCl) and platinum wire (1 mm diameter) were used as the reference and counter electrodes, respectively. Grafted polymer electrode self modified with AC was used as a working electrode in this study. The voltammetric experiments were carried out with 0.1 M KCl as supporting electrolyte and using K 3 Fe(CN) 6 solution for calibration. The solution was degassed with nitrogen gas for 10 15 min prior to recording the voltammogram. Reagents All reagents were analytical reagents or electrochemical grade purity. All solutions were prepared using double distilled water. Unless otherwise specified, the supporting electrolyte was used 0.1 M KCl in aqueous media at room temperature. Fabrication of grafted polymer electrode self modified with activated carbon (GPESMAC) GPESMAC has been fabricated from grafted polymer modified with activated carbon. The diameter of electrode was 3 cm. A (1 mm) hole was made in the grafted polymer to allow 1 cm length of platinum wire out from the other side of electrode. A copper wire was then joined with the platinum wire. After that, all parts of fabricated electrode were covered with glassy tube and then fixed with epoxy resin. Results and discussion Electrochemical properties of grafted polymer electrode self modified with activated carbon (GPESMAC) Potential window of GPESMAC 0.1 M of potassium chloride solution is commonly used as a reference standard for the purpose of calibrating a voltammetric system in aqueous solutions. During the calibration process of the electroanalytical workstation using GPESMAC as a working electrode, comparison with the working potential window of GCE/AC (using attachment method for modification GCE with AC) was found to be in the range (-1.8 to?1.8 V) with large value of capacity as show in Fig. 1a with small significant peaks appearing at?1.4 V. A considerable extension of the working window with the absence of each, especially at the anodic region, is observed when GPESMAC is used. Although the working window at the anodic and cathodic

Int J Ind Chem (2016) 7:103 108 105 Fig. 1 Cyclic voltammetry of different electrodes a glassy carbon electrode modified with activated carbon by mechanical attachmemt method, b grafted polymer electrode self modified with activated carbon in 0.1 M KCl as supporting electrolyte versus Ag/AgCl and 100 mv s -1 Fig. 4 Plot Ipc(cathodic current) versus different concentration K 3 [Fe(CN) 6 ] (0.3 1 mm) in 0.1 M KCl at scan rate 100 mv s -1 using GPESMAC versus Ag/AgCl appearing at about -1.5 to?2.0 V with low capacity as show in Fig. 1b. This limiting current, however, diminishes in subsequent cycles allowing the potential working window to be widened at the anodic region to near 2.0 V. Effect of GPESMAC on the redox reaction of K 3 [Fe(CN) 6 ] during CV It was found that the redox potential of GPESMAC in 1mM K 3 Fe(CN) 6 with 0.1 M KCl as supporting electrolyte with anodic and cathodic potential peaks as shown in Fig. 2: Epa ¼þ200 mvðoxidation potential of anodic peakþ Epc ¼þ100 mvðreduction potential of cathodic peakþ Fig. 2 Cyclic voltammetry of GPESMAC in 1 mm K 3 Fe(CN) 6 with 0.1 M KCl as supporting electrolyte versus Ag/AgCl and 100 mv s -1 LogIpa 3.1 3 2.9 2.8 2.7 2.6 2.5 2.4 2.3 2.2 2.1 y = 0.4388x + 1.7912 R 2 = 0.9988 0.69 1.19 1.69 2.19 2.69 3.19 logv Fig. 3 Plot log Ipa (anodic current) versus log (scan rate) of GPESMAC in 0.1 M KCl and 1 mm K 3 Fe(CN) 6 versus Ag/AgCl and scan rate 5 500 mvs -1 regions deteriorates, this is due to the electrocatalyzed oxidation reduction of the aqueous electrolyte or the reactivity of GPESMAC giving rise to a limiting current with peak separation of 100 mv (for n = 1) in 0.1 M KCl electrolyte indicates the reversible reaction of the Fe(III)/ Fe(II) couples in KCl solution, and agrees well with the accepted values. Effect of varying scan rate The effect of varying scan rates on the cyclic voltammograms using GPESMAC as working electrode in 0.1 M KCl supporting electrolyte was studied with 1mMK 3 Fe(CN) 6 over a scan rate range of 5 500 mv s -1. Oxidation and reduction currents of the Fe(III)/Fe(II) couple was observed to increase with scan rate due to heterogeneous kinetics and IR effect. Based on a plot of log(ipa) versus log (scan rate) for the oxidation current of the first cycle, a straight line was obtained in Fig. 3 fulfilling the equation: y = 0.4388 X? 1.7912 with R 2 = 0.9988. A slope of 0.44 is quite comparable with the theoretical slope of 0.5 for the diffusion controlled process. Effect of varying temperature Effect of temperature on the redox process of K 3 Fe(CN) 6 was studied on GPESMAC. The current increases gradually

106 Int J Ind Chem (2016) 7:103 108 Fig. 5 SEM of a grafted polymer, b grafted polymer modified with CNT at a temperature of 10 90 C. Plots of log (Ia) oxidation current of K 3 Fe(CN) 6 versus the reciprocal of temperature, which is found to be fairly linear in agreement with the thermodynamic expectation of Arrhenius equations [15]: r ¼ r Exp ð Ea= RT Þ ð1þ D ¼ D Exp ð Ea= RTÞ ð2þ where: r/d are conductivity/diffusibility and r /D are standard conductivity/the initial diffusibility. From the relationship between log(ia) and 1/T of the oxidation K 3 Fe(CN) 6 as Fe(II)/Fe(III) the activation energy was found 6.32 kj/mol in GPESMAC comparison with other studies [16]. Effect of varying K 3 Fe(CN) 6 concentration Figure 4 shows the linear current dependent on K 3 Fe(CN) 6 concentration; observed at concentration range (5 10 mm) which is described by the equation of y = 28.372X? 2.2268 with R 2 = 0.9904. The slope of the linear line for K 3 Fe(CN) 6 showed that a considerably high

Int J Ind Chem (2016) 7:103 108 107 Fig. 6 AFM of grafted acrylonitrile on polystyrene a before modified with activated carbon, b after modification sensitivity response of 28 la/mm is readily obtained at GPESMAC during cyclic voltammetry. Reproducibility The potential cycling of the redox of GPESMAC in 1 mm K 4 Fe(CN) 6 and 1 M KCl aqueous solution as a supporting electrolyte was carried out during cyclic voltammetry. Continuous potential cycling did not seem to affect the redox current of GPESMAC as the faradic activity appears reproducible even after 15 cycles, reflecting the stability and reproducibility at the surface of GPESMAC. Scanning electron microscopy (SEM) of GPE/AC Before modification grafted polymer surface appears compact and nonporous. The uniformity of the grafted polymer surface slightly increases since occurrence of protrusion observed phase as shown in Fig. 5a. After modification with AC, although many of the species deposits with homogenous distribution of AC still remain at about \1 lm as show in Fig. 5b. Atomic force microscopy (AFM) The surface image of AFM in an area of 20 lm 9 20 lm of the grafted polymer (polystyrene acrylonitrile) before and after modified with AC as shown in Fig. 6a, b respectively. The surface of the electrode appeared to be compact and rough. According to AFM images, the average species size and thickness of the film were estimated to be 11.23 and 28.69 lm, respectively. Conclusion A grafted polymer electrode self modified with activated carbon GPESMAC has been fabricated in laboratory for using in cyclic voltammetric technique as a working

108 Int J Ind Chem (2016) 7:103 108 electrode. The new electrode was used as alternative of working electrodes modified with deposit materials such as activated carbon using classical modification methods (attachment or solvent evaporation methods). The CV analysis results of these electrodes have an extended potential working region as compared to the routine modification method of GCE with activated carbon and have high stability and reproducibility. Redox peaks of Fe(II)/Fe(III) showed high current as compared with other modified electrodes. Electro-catalytic activity of GPESMAC is therefore evident in this study, it was studied by redox process of K 3 Fe(CN) 6 during cyclic voltammetry. The redox peaks potential shifts slightly to less negative value by about 100 mv for oxidative peak and 50 mv for reductive peak with current enhancement of about 3-fivefolds. The sensitivity under conditions of cyclic voltammetry is significantly dependent on the concentration, scan rate and temperature. Excellent reproducibility and stability of the current is observed, provided a fabricated electrode is used for each experiment without any polishing. Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://crea tivecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. References 1. Bhattacharya A, Misra BN (2010) Grafting: a versatile means to modify polymers techniques, factors and applications. Prog Polym Sci 29:767 814 2. Radhi MM, Tan WT, Ab Rahman MZ, Kassim AB (2010) Voltammetric detection of Hg(II) at C60, activated carbon and MWCNT modified glassy carbon electrode. Res J Appli Sci 5:59 64 3. Radhi MM, Tan WT, Ab Rahman MZ, Kassim AB (2010) Electrochemical redox of Hg 2? mediated by activated carbon modified glassy carbon Electrode. Int J Electrochem Sci 5:615 629 4. Radhi MM, Tan WT, Rahman MZ, Kassim AB (2012) Synthesis and characterization of grafted acrylonitrile on polystyrene modified with activated carbon using gamma-irradiation. Sci Res Ess 7:790 795 5. Radhi MM, Al-Mulla EAJ (2015) Use of a grafted polymer electrode to study mercury ions by cyclic voltammetry. Res Chem Intermed 41:1413 1420 6. Tan WT, Radhi MM, Ab Rahman MZ, Kassim AB (2011) Application studies to voltammetric detection of trace Hg(II) by different modified solid glassy carbon electrode. Austr J Basic Appli Sci 5:2475 2481 7. Abdullah AA, Aowda SA (2013) Electrochemical studies of copper fatty amides complex in organic medium. Res Chem Intermed 39:2817 2823 8. Yunus WMZ, Ibrahim NAB, Rahman MZA (2010) Epoxidized palm oil plasticized polylactic acid/fatty nitrogen compound modified clay nanocomposites: preparation and characterization. Polym Polym Comp 18:451 459 9. Radhi MM, Al-Mulla EAJ (2014) Application study of grafted polymer electrode in manganese ions during cyclic voltammetry. Rend Lincei Sci Fis Nat 25:209 213 10. Shemmari FA, Rabah AA (2014) A comparative study of different surfactants for natural rubber clay nanocomposite preparation. Rend Lincei Sci Fis Nat 25:409 413 11. Al-Mulla EAJ (2011) Lipase-catalyzed synthesis of fattythioic acids from palm oil. J Oleo Sci 60:41 45 12. Yunus WMZ, Ibrahim NAB, Rahman MZA (2010) Difatty acyl urea from corn oil: synthesis and characterization. J Oleo Sci 59:157 160 13. Al-Mulla EAJ (2011) Preparation of polylactic acid/epoxidized palm oil/fatty nitrogen compounds modified clay nanocomposites by melt blending. Polym Sci Series A 53:149 157 14. Issam AM, Al-Janabi KW (2015) A novel method for the synthesis of biodiesel from soybean oil and urea. C R Chim 18:525 529 15. Tan WT, Lim E, Bond A (2003) Voltammetric studies on microcrystalline C60 adhered to an electrode surface by solvent casting and mechanical transfer methods. J Solid State Electrochem 7:134 140 16. Radhi MM, Al-Mulla EAJ, Tan WT (2014) Electrochemical characterization of the redox couple of Fe(III)/Fe(II) mediated by grafted polymer electrode. J Res Chem Intermed 40:179 192