Physics. Nuclear Physics University Experiments. Training and Experimental System for Students

Similar documents
Alpha-Energies of different sources with Multi Channel Analyzer

Alpha-energies of different sources with Multi Channel Analyzer (Item No.: P )

β-spectroscopy Fig. 1: Experimental set-up for determining inductance from the resonant frequency of an oscillatory circuit.

Quality Assurance. Purity control. Polycrystalline Ingots

SCINTILLATION DETECTORS & GAMMA SPECTROSCOPY: AN INTRODUCTION

Detection and measurement of gamma-radiation by gammaspectroscopy

Rutherford experiment with MCA

Jazan University College of Science Physics Department. Lab Manual. Nuclear Physics (2) 462 Phys. 8 th Level. Academic Year: 1439/1440

X-ray fluorescence analysis - calibration of the X-ray energy detector

hν' Φ e - Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous?

PRODUCTS FOR EDUCATION AND TRAINING

GAMMA RAY SPECTROSCOPY

Absorption of X-rays

GLOSSARY OF BASIC RADIATION PROTECTION TERMINOLOGY

Copyright 2008, University of Chicago, Department of Physics. Experiment VI. Gamma Ray Spectroscopy

Radionuclide Imaging MII Detection of Nuclear Emission


Energy loss of alpha particles - Prelab questions

Atoms, Radiation, and Radiation Protection

This experiment is included in the XRP 4.0 X-ray solid state, XRS 4.0 X-ray structural analysis, and XRC 4.0 X-ray characteristics upgrade sets.

Radiation Detection and Measurement

Analysis of γ spectrum

Ion-Chamber Survey Meter OD-02

"Neutron Flux Distribution"

Radiation Detection. 15 th Annual OSC Readiness Training Program.

Alpha-particle Stopping Powers in Air and Argon

EXAMINATION QUESTIONS (6)

Activities at the Laboratory of the Nuclear Engineering Department of the Polytechnic University of Valencia

Scintillation Detector

Nuclear Physics and Astrophysics

EEE4106Z Radiation Interactions & Detection

Radiation and Radioactivity. PHYS 0219 Radiation and Radioactivity

Nuclear Physics Lab I: Geiger-Müller Counter and Nuclear Counting Statistics

Chapter 30 Nuclear Physics and Radioactivity

EQUIPMENT Beta spectrometer, vacuum pump, Cs-137 source, Geiger-Muller (G-M) tube, scalar

Introduction to Environmental Measurement Techniques Radioactivity. Dana Pittauer 1of 48

PHYSICS A2 UNIT 2 SECTION 1: RADIOACTIVITY & NUCLEAR ENERGY

Absolute activity measurement

(a) (i) State the proton number and the nucleon number of X.

Science of Nuclear Energy and Radiation a Comprehensive Course for Science Teachers June 22-25, 1998 McMaster University

MEASUREMENT AND DETECTION OF RADIATION

Modern Physics Laboratory (Physics 6180/7180)

1. Introduction. Etim I.P. 1, William E. S. 2, Ekwe S.O. 3. Licensed Under Creative Commons Attribution CC BY

Gamma Spectroscopy. References: Objectives:

Lab NUC. Determination of Half-Life with a Geiger-Müller Counter

Higher -o-o-o- Past Paper questions o-o-o- 3.6 Radiation

SCINTILLATION DETECTORS AND PM TUBES

Experiment 6 1. The Compton Effect Physics 2150 Experiment No. 6 University of Colorado

Determination of the Rydberg constant, Moseley s law, and screening constant (Item No.: P )

General Overview of Radiation Detection and Equipment

Radioactivity. The Nobel Prize in Physics 1903 for their work on radioactivity. Henri Becquerel Pierre Curie Marie Curie

Modern Physics Laboratory Beta Spectroscopy Experiment

Introduction. Principle of Operation

Radioactivity. is related to de/dx. The range, R, is defined by the integral of de/dx:

DETECTORS. I. Charged Particle Detectors

BETA-RAY SPECTROMETER

Part 12- Physics Paper 1 Atomic Structure Knowledge Questions

9 Nuclear decay Answers to exam practice questions

Absorber Alpha emission Alpha particle Atom. Atomic line spectra Atomic mass unit Atomic number Atomic structure. Background radiation

Strand J. Atomic Structure. Unit 2. Radioactivity. Text

The Compton Effect. Martha Buckley MIT Department of Physics, Cambridge, MA (Dated: November 26, 2002)

ORTEC Experiment 24. Measurements in Health Physics. Equipment Required

Fundamentals of Radionuclide Metrology

ORTEC AN34 Experiment 10 Compton Scattering

CHAPTER 12 TEST REVIEW

RANGE OF ALPHAS. Advanced Laboratory, Physics 407 University of Wisconsin Madison, Wisconsin 53706

Characteristic X-rays of molybdenum

FYSP106/K3 GEIGER & MÜLLER TUBE. 1 Introduction. 2 The equipment

Chapter Seven (Nuclear Detectors)

1 of :32

Some nuclei are unstable Become stable by ejecting excess energy and often a particle in the process Types of radiation particle - particle

Advanced lab course for Bachelor s students

Nuclear Physics Laboratory. Gamma spectroscopy with scintillation detectors. M. Makek Faculty of Science Department of Physics

Topic 7 &13 Review Atomic, Nuclear, and Quantum Physics

Survey Meter OD-01 Address: Phone: Fax: URL:

CHAPTER 7 TEST REVIEW

Analytical Technologies in Biotechnology Prof. Dr. Ashwani K. Sharma Department of Biotechnology Indian Institute of Technology, Roorkee

Contents. Charged Particles. Coulomb Interactions Elastic Scattering. Coulomb Interactions - Inelastic Scattering. Bremsstrahlung

Development of a Silicon PIN Diode X-Ray Detector

Radioactivity III: Measurement of Half Life.

5 Atomic Physics. 1 of the isotope remains. 1 minute, 4. Atomic Physics. 1. Radioactivity 2. The nuclear atom

QUIZ: Physics of Nuclear Medicine Atomic Structure, Radioactive Decay, Interaction of Ionizing Radiation with Matter

Chapter 29. Nuclear Physics

Radiation (Particle) Detection and Measurement

Radioactivity. Lecture 6 Detectors and Instrumentation

Gamma Ray Spectroscopy

SECTION A Quantum Physics and Atom Models

Radioactivity and Ionizing Radiation

Warsaw University of Technology, Faculty of Physics. Laboratory of Nuclear Physics & Technology. Compton effect

International Journal of Scientific & Engineering Research, Volume 5, Issue 3, March-2014 ISSN

Radioactivity and energy levels

Gamma and X-Ray Detection

IGCSE Physics 0625 notes: unit 5 Atomic Physics: Revised on 01 December

11 Gamma Ray Energy and Absorption

Atomic and nuclear physics

Alpha decay usually occurs in heavy nuclei such as uranium or plutonium, and therefore is a major part of the radioactive fallout from a nuclear

Conclusion. 109m Ag isomer showed that there is no such broadening. Because one can hardly

TEP Examination of the structure of NaCl monocrystals with different orientations

Chapter 3 Radioactivity

CASSY Lab. Manual ( )

Transcription:

Physics Nuclear Physics University Experiments Training and Experimental System for Students

Nuclear Physics - Radioactivity Half-life and radioactive equilibrium Poisson's and Gaussian distribution of radioactive decay Alpha Particles - Energy - Rutherford Experiment Beta Particles - Electron Absorption Gamma Particles - Energy - Compton Effect Counter tube characteristics X-ray dosimetry 1 2 3 8 10 14 15 PHYWE Systeme GmbH & Co. KG www.phywe.com

Half-life and radioactive equilibrium P2520101 Half-life and radioactive equilibrium Logarithmic plot of the counting rate of the eluted daughter substance as a function of time. The half-life of a Ba-137 m daughter substance eluted (washed) out of a Ca-137 isotope generator is measured directly and is also determined from the increase in activity after elution. 1. To record the counting rate as a function of the counter tube voltage (counter tube characteristic) when the isotope generator activity is constant (radioactive equilibrium). 2. To measure the activity of the isotope generator as a function of time immediately after elution. Parent substance, Daughter substance, Rate of decay Disintegration or decay constant, Counting rate, Half life Disintegration product Related Experiment Half-life and radioactive equilibrium with Cobra3 P2520111 Cobra4 Experiment Half-life and radioactive equilibrium with Cobra4 P2520160 Isotope generator Cs-137, 370 kbq 09047-60 1 Pulse rate meter 13622-93 1 Geiger-Mueller Counter tube, type A, BNC 09025-11 1 Digital multimeter 2010 07128-00 1 Base plate for radioactivity 09200-00 1 Plate holder on fixing magnet 09203-00 1 Counter tube holder on fix.magn. 09201-00 1 Marie Curie 1903, Nobel Prize in Physics excellence in science 4

Poisson's and Gaussian distribution of radioactive decay Poisson's and Gaussian distribution of radioactive decay with Cobra4 (Influence of the dead time of the counter tube) P2520360 Pulse rate distribution for high pulse rate (248 pulses/s) with an adapted Gaussian curve (left window) and a Poisson's curve (right window). 1) The aim of this experiment is to show that the number of pulses counted during identical time intervals by a counter tube which bears a fixed distance to along-lived radiation emitter correspond to a Poisson s distribution. A special characteristic of the Poisson s distribution can be observed in the case of a small number of counts n < 20: The distribution is unsymmetrical, i. e. the maximum can be found among smaller numbers of pulses than the mean value. In order to show this unsymmetry the experiment is carried out with a short counting period and a sufficiently large gap between the emitter and the counter tube so that the average number of pulses counted becomes sufficiently small. 2) Not only the Poisson's distribution, but also the Guassian distribution which is always symmetrical is very suitable to approximate the pulse distribution measured by means of a long-lived radiation emitter and a counter tube arranged with a constant gap between each other.a premise for this is a sufficiently high number of pulses and a large sampling size. The purpose of the following experiment is to confirm these facts and to show that the statistical pulse distribution can even be approximated by a Guassian distribution, when (due to the dead time of the counter tube) counting errors occur leading to a distribution which deviates from the Poisson's distribution. 3) If the dead time of the counter tube is no longer small with regard to the average time interval between the counter tube pulses, the fluctuation of the pulses is smaller than in the case of a Poisson's distribution. Poisson's distribution; Gaussian distribution; Standard deviation Expected value of pulse rate; Different symmetries of distributions; Dead time Recovering time and resolution time of a counter tube Radioactive source Am-241, 370 kbq 09090-11 1 Software Cobra4 - multi-user licence 14550-61 1 Geiger-Mueller Counter tube, type A, BNC 09025-11 1 Cobra4 Wireless-Link 12601-00 1 Cobra4 Sensor-Unit Radioactivity 12665-00 1 Cobra4 Wireless Manager 12600-00 1 Base plate for radioactivity 09200-00 1 Cobra4 Sensor-Unit Radioactivity The Cobra4 Sensor-Unit Radioactivity allows the measurement of radioactive radiation (alpha, beta and gamma) with the aid of a Geiger-Mueller counter tube. The Sensor-Unit also supplies the counter tube with the necessary supply voltage and is controlled by a micro-controller. Benefits It can be fitted with 3 different counter tubes Variable counter tube voltage to investigate the characteristics of the counter tube Integrated speaker for acoustic signal of the counted pulses The unit can be connected to the Cobra4 Wireless-Link, the Cobra4 Mobile-Link, the Cobra4 Junior-Link or the Cobra4 USB- Link using a secure and reliable plug-in / lockable connection 12665-00 PHYWE Systeme GmbH & Co. KG www.phywe.com 5

Alpha Particles - Energy - Rutherford Experiment P2522015 Alpha energies of different sources with MCA Alpha-spectrum of the 226 Ra. An alpha-spectrometer, consisting of a photodetector, a preamplifier, a pulse height analyser and a recording device for registration of the spectra is calibrated by means of an open alpha-emitter of known alpha energy ( 241 Am). The energy spectrum of a radium source which is in equilibrium with its decay products, is recorded and evaluated. The alpha-energies found in this way are allocated to the corresponding nuclides of the radium decay series. 1. The Alpha-spectrum of the 226 Ra is recorded with multichannel analyzer. 2. The calibration spectrum of the open 241 Am alpha-emitter is recorded at the same settings. 3. The alpha-energies corresponding to the individual peaks of the alphaspectrum of the radium are calculated and compared to the values in the literature. Decay series; Radioactive equilibrium Isotopic properties Decay energy Particle energy Potential well model of the atomic nucleus Tunnel effect Geiger-Nuttal law Semiconductor Barrier layer Multichannel analyser The multichannel analyser is for analysing voltage pulses which are proportional to energy and for determining pulse rates and intensities in conjunction with an X-ray detector, alpha detector or gamma detector. The analogue pulses from the detector are shaped by the analyser, digitised and summed per channel according to pulse height. This results in a frequency distribution of detected pulses dependent on the energy of the radiation. 13727-99 Multi channel analyser 13727-99 1 Radioactive source Am-241, 3.7 kbq 09090-03 1 Radioactive source Ra-226, max. 4 kbq 09041-00 1 Pre-amplifier f.alpha detector 09100-10 1 Alpha and Photodetector 09099-00 1 6 excellence in science

Alpha Particles - Energy - Rutherford Experiment Rutherford experiment with MCA P2522115 Counting rate for gold as a function of 1. The relationship between the angle of scattering and the rate of scattering of alpha-particles by gold foil is examined with a semiconductor detector. This detector has a detection probability of 1 for alpha-particles and virtually no zero effect, so that the number of pulses agrees exactly with the number of alpha-particles striking the detector. In order to obtain maximum possible counting rates, a measurement geometry is used which dates back to Chadwick. It is also possible in this case to shift the foil and source in an axial direction (thus deviating from Chadwick's original apparatus), so that the angle of scattering can be varied over a wide range. In addition to the annular diaphragm with gold foil, a second diaphragm with aluminium foil is provided in order to study the influence of the scattering material on the scattering rate. 1. The particle rates are measured at different angles of scattering between about 20 and 90. The measurements are compared with the particle rates calculated by means of the Rutherford theory for the measurement geometry used. 2. The particle rates are measured in the case of scattering by aluminium and gold with identical angles of scattering in each case. The ratio of the two particle rates is compared with the particle rate calculated from Rutherford's scattering equation. Scattering Angle of scattering Impact parameter Central force Coulomb field Coulomb forces Rutherford atomic model Identity of atomic number and charge on the nucleus Alpha detector 09100-00 1 Multi channel analyser 13727-99 1 Container f.nuclear phys.expts. 09103-00 1 Radioactive source Am-241, 370 kbq 09090-11 1 Pre-amplifier f.alpha detector 09100-10 1 Ernest Rutherford 1908, Nobel Prize in Physics PHYWE Systeme GmbH & Co. KG www.phywe.com 7

Alpha Particles - Energy - Rutherford Experiment P2522215 Fine structure of the alpha spectrum of Am-241 with MCA / alpha spectroscopy Measured alpha-spectrum of 241 Am. The alpha-spectrum of an open 241 Am-emitter is measured with a semiconductor a-detector, maximum use being made in this case of the resolution capacity of the pulse height analyzer. Use is made for this purpose of the "Zoom" function, which is an additional amplification stage having in the effect that only that proportion of the pulses exceeding the threshold voltage of 5 V undergoes further processing. The pulse peaks above this threshold are amplified 5 times and restricted to a maximum of 10 V. 1. The spectrum of an open 241 Am-emitter is recorded with the xyt recorder at the maximum resolution capacity of the measurement layout, using automatic window movement. The energy of the two peaks preceding the principal peak is calculated. The principal peak, corresponding to a particle energy of 5.486 MeV, is used for calibration purposes. 2. The resolution capacity of the measurement layout is measured from the half-life width of the principal peak. Energy level diagram (decay diagram) Transition probability Excited nuclear states γ-emission Connection between the fine structure of the α-spectrum and the accompanying γ-spectrum Container for nuclear physics exp. Container for nuclear physical experiments. Equipment and technical data Cylindrical glasstube, 75 mm diam., 400 mm long, with a printed on scale 0 to 28 cm and metal flanges at its end. Removable by knurled head screws. One flange with vacuum tight centrally fitted bearing for a.push-rod for radioactive source adaption. Second flange with adaptors for vacuum system and detector. 09103-00 Multichannel analyser 13727-99 1 Container for nuclear physics exp. 09103-00 1 Radioactive source Am-241, 3.7 kbq 09090-03 1 Diaphragm pump, two stage, 220V 08163-93 1 Vacuum gauge DVR 2, 1... 1000 hpa 34171-00 1 8 excellence in science

Alpha Particles - Energy - Rutherford Experiment Study of the alpha energies of Ra-226 with MCA P2522315 226 Ra pulse rate dependence of pulse height. An alpha-spectrometer, consisting of a silicon surface barrier layer detector, a preamplifier, a pulse height analyser and a recording device for registration of the spectra is calibrated by means of an open alpha-emitter of known alpha-energy ( 241 Am). The energy spectrum of a radium source which is in equilibrium with its decay products, is recorded and evaluated. The alpha-energies found in this way are allocated to the corresponding nuclides of the radium decay series. 1. The alpha-spectrum of the 226 Ra is recorded, the settings of the pulse analyzer (amplification) and recorder (x and y input sensitivity) being selected so as to make best possible use of the recording width. 2. The calibration spectrum of the open 241 Am-emitter is recorded at the same settings. 3. The alpha-energies corresponding to the individual peaks of the alpha spectrum of the radium are calculated and, on the assumption of a constant energy loss in the source covering, the alpha-active nuclides of the radium decay series corresponding to the individual peaks are determined on the basis of the values in the literature. Decay series Radioactive equilibrium Isotopic properties Decay energy Particle energy Potential well model of the atomic nucleus Tunnel effect Geiger-Nuttal law Semiconductor Barrier layer Multichannel analyser 13727-99 1 Container for nuclear physics exp. 09103-00 1 Radioactive source Am-241, 3.7 kbq 09090-03 1 Diaphragm pump, two stage, 220V 08163-93 1 Radioactive source Ra-226, max. 4 kbq 09041-00 1 Vacuum gauge DVR 2, 1... 1000 hpa 34171-00 1 Pre-amplifier f.alpha detector 09100-10 1 PHYWE Systeme GmbH & Co. KG www.phywe.com 9

Alpha Particles - Energy - Rutherford Experiment P2522415 Energy loss of alpha particles in gases with MCA Influence of the type of gas on the energy loss of alpha particles. A study is made of the connection between the energy E of alphaparticles and the path x travelled by them in air at standard pressure. The measurements recorded enable the differencial energy loss de/ dx to be calculated as a function of x. 1. The spectrum of a covered 241Am source is measured at a fixed distance s as a function of the pressure p. The distance s is selected in such a way as to correspond to the maximum range at the highest pressure measurable with the manometer used. The energy corresponding to the central points of the individual spectra are determined (after calibration of the measurement layout with an open 241Am-emitter, see 3.) and plotted as a function of the distance x converted to a 1013 hpa basis. Using this function, the differential energy loss (de/dx) is then calculated as a function of x and again plotted on the graph. 2. The spectrum of the source used in 1.is measured initially under the same geometric conditions under vacuum and subsequently with the vessel filled with helium, nitrogen or carbon dioxide, in each case under identical pressures. The different energy loss values are compared with the electron concentration in the particular gas. 3. The mean energy with which the alpha-particles leave the covered americium source is determined by calibration against the open americium emitter (E = 5.485 MeV). (This value is required for the evaluation in 1.) Range; Range dispersion Mean free path length Mean ionization energy of gas atoms Mean energy loss of a-particles per collision Differencial energy loss; Bethe formula Multichannel analyser 13727-99 1 Container for nuclear physics exp. 09103-00 1 Radioactive source Am-241, 3.7 kbq 09090-03 1 Radioactive source Am-241, 370 kbq 09090-11 1 Diaphragm pump, two stage, 220V 08163-93 1 Vacuum gauge DVR 2, 1... 1000 hpa 34171-00 1 Pre-amplifier f.alpha detector 09100-10 1 Diaphragm pump, two stage, 220V Diaphragm pump, two stage. Benefits Maintenance-free, insensitve towards condensates, quiet, lightweight and easy to use because motor and compressor are together in one unit. It has a carryinghandle, overpressure valve 1.5 bar, toggle switch, working condenser and light metal casing. Equipment and technical data Aspirating power 30 l/min, Final pressure 13 mbar Pump head: Al, Valves: stainless steel Membrane and seals: CR (polychloroprene) Dimensions 323 x 250 x 222 mm Power supply voltage 230 V AC 08163-93 excellence in science 10

Beta Particles - Electron Absorption Electron absorption P2523100 Counting rate I as a function of absorber thickness. The attenuation of an electron particle stream passing through a material layer depends both on the thickness of the layer and on the mass coverage, resp. the "mass per unit area". It will be shown that the particle flux consisting of electrons of a particular energy distribution decreases with the "mass per unit area". As electron source, a radioactive sample of 90 Sr is used. 1. The beta-counting rates are measured as a function of the absorber thickness using different absorbing materials such as aluminium (AL), glass (GL), hard paper (HP) and typing paper (TP). 2. The attenuation coefficients are evaluated for the four absorbing materials and plotted as a function of the density. Density Counter tube Radioactive decay Attenuation coefficient Mass coverage Radioactive source Sr-90, 74 kbq 09047-53 1 Geiger-Müller-Counter 13606-99 1 Geiger-Mueller Counter tube, type A, BNC 09025-11 1 Absorption plates f. beta-rays 09024-00 1 Base plate for radioactivity 09200-00 1 Supports f. base 09200.00, 2 pcs 09200-01 1 Plate holder on fixing magnet 09203-00 1 Geiger-Müller-Counter Demonstration and student use unit in connection with Geiger Müller counting tubes for experiments on radioactivity. Equipment and technical data 4-digit LED display, 20mm high.4 standard measurement times 1/10/60/100 s, Automatic measurement sequence with memory 10 s Freely selectable measuring time, BNC-socket for counting tube 500V 4-mm-bushes for event counting with TTL signals, Mains 100-230 V/50-60 Hz, Shock proof casing with carrying handle Dimensions 190 x 140 x 130 mm 13606-99 PHYWE Systeme GmbH & Co. KG www.phywe.com 11

Beta Particles - Electron Absorption P2523200 Beta spectroscopy Beta-spectrum of 90 Sr. The radiation of β-unstable atomic nuclei is selected on the basis of its pulses in a magnetic transverse field, using a diaphragm system. The relationship between coil current and particle energy is determined for calibration of the spectrometer and the decay energy of the β-transition is obtained in each case from the β - -spectra. 1. Energy calibration of the magnetic spectrometer. 2. Measurement of the β-spectra of 90 Sr and 20 Na. 3. Determination of the decay energy of the two isotopes. β - -decay β + -decay Electron capture Neutrino Positron Decay diagram Decay energy Resting energy Relativistic Lorentz equation Teslameter, digital 13610-93 1 Power supply, universal 13500-93 1 Radioactive source Na-22, 74 kbq 09047-52 1 Radioactive source Sr-90, 74 kbq 09047-53 1 Geiger-Müller-Counter 13606-99 1 Beta-spectroscope 09104-00 1 Geiger-Mueller Counter tube, type A, BNC 09025-11 1 Beta-spectroscope Beta spectroscope. Equipment and technical data Cylindrical chamber with base plate with diaphragm system. Top plate removable. Lateral bore-holes for radioactive source and flux-meter probe. Diameter: 90 mm. Height: 20 mm. 09104-00 excellence in science 12

Gamma Particles - Energy - Compton Effect Inverse-square law and absorption of gamma or beta rays with the Geiger-Müller counter P2524101 Attenuation coefficient of different materials as a function of the material density (from left to right: Plexiglas, concrete, aluminium, iron, lead). The inverse square law of distance is demonstrated with the gamma radiation from a 60Co preparation, the half-value thickness and absorption coefficient of various materials determined with the narrow beam system and the corresponding mass attenuation coefficient calculated. 1. To measure the impulse counting rate as a function of the distance between the source and the counter tube. 2. To determine the half-value thickness d1/2 and the absorption coefficient of a number of materials by measuring the impulse counting rate as a function of the thickness of the irradiated material. Lead, iron, aluminium, concrete and Plexiglas are used as absorbers. 3. To calculate the mass attenuation coefficient from the measured values. Radioactive radiation; Beta-decay; Conservation of parity Antineutrino; Gamma quanta; Half-value thickness Absorption coefficient; Term diagram; Pair formation Compton effect; Photoelectric effect Conservation of angular momentum; Forbidden transition Weak interaction; Dead time Radioactive sources, set 09047-50 1 Geiger-Müller-Counter 13606-99 1 Geiger-Mueller Counter tube, type A, BNC 09025-11 1 Absorption material, lead 09029-01 1 Absorption plates f. beta-rays 09024-00 1 Absorption material, concrete 09029-05 1 Radioactive sources, set Set of 4 encapsulated radionuclides, radiation sources with storage container. Equipment and technical data valid handling licence necessary notifiable to your supervisory authority Alpha Am-241, Hwz: 433 a Beta(+) Na- 22, Hwz: 2,6 a Beta(-) Sr- 90, Hwz: 28,5 a Gamma Co- 60, Hwz: 5,3 a Activity each source: 74 kbq 09047-50 PHYWE Systeme GmbH & Co. KG www.phywe.com 13

Gamma Particles - Energy - Compton Effect P2524215 Energy dependence of the gamma absorption coefficient with MCA / Gamma spectroscopy Total gamma-absorption coefficient as a function of the energy. The intensity of gamma-radiation decreases when it passes through solid matter. The attenuation can be the result of Compton scattering, the photo effect or the pair production. An absorption coefficient can be attributed to each of the three phenomena. These absorption coefficients, as well as the total absorption, are highly energy-dependent. The energy dependence of the total absorption coefficient for aluminium in the range below 1.3 MeV is verified. 1. For each of the emitting isotopes 22 Na, 137 Cs and 241 Am the gamma-spectrum is traced and a threshold energy, E, just below the photo-peak in the high energy range determined. 2. Using the scintillation counter in conjunction with the pulse height analyser as a monochromator, the gamma-intensity is measured as a function of the thickness of different aluminium layers.the three gamma- emitting isotopes are used successively as the source, assuming that the energy of the emitted gamma-radiation is known. Compton scattering Photo effect Pair production Absorption coefficient Radioactive decay g-spectroscopy Gamma detector 09101-00 1 Multi channel analyser 13727-99 1 Radioactive source Cs-137, 37 kbq 09096-01 1 Radioactive source Am-241, 370 kbq 09090-11 1 Operating unit for gamma detector 09101-93 1 Radioactive source Na-22, 74 kbq 09047-52 1 measure Software multi channel analyser 14452-61 1 Gamma detector To detect gamma, beta and x-rays. Large volume thallium doped NaI-crystal in light-tight capsule, with photomultiplier with mumetal shielding mounted in holder with rod. Equipment and technical data: Crystal: NaI (Ta). Crystal dimensions (mm): 38 x 50.8. Thickness of Al envelope: 0.4 mm. Operation voltage: 600..1100 V. 09101-00 excellence in science 14

Gamma Particles - Energy - Compton Effect Internal conversion in 137m Ba with MCA P2524515 Gamma-spectrum of 137 Cs. The radiation emitted during the decay of the 137 Cs isotope is measured with a scintillation detector and the energyspectrum determined with a pulse height analyzer. The spectrum contains fractions due to a gamma-transition and fractions originating from a characteristic X-ray radiation. The areas of the fractions in question are determined and the conversion factor obtained from them. 1. Measurement of the g-spectrum of 137 Cs using a scintillation detector. 2. Determination of the conversion factor of the 137 mba excited nucleus. g-radiation; Nuclear transitions Transition probability Duration; Metastable states Isotopic spin quantum numbers Rules governing selection Multipole radiation; Isomeric nuclei Photonuclear reaction; Conversion electron Characteristic X-ray radiation Scintillation detectors Gamma detector 09101-00 1 Multi channel analyser 13727-99 1 Radioactive source Cs-137, 37 kbq 09096-01 1 Operating unit for gamma detector 09101-93 1 measure Software multi channel analyser 14452-61 1 Multi channel analyser Function and applications The multichannel analyser is for analysing voltage pulses which are proportional to energy and for determining pulse rates and intensities in conjunction with an X-ray detector, alpha detector or gamma detector. The analogue pulses from the detector are shaped by the analyser, digitised and summed per channel according to pulse height. This results in a frequency distribution of detected pulses dependent on the energy of the radiation. Equipment and technical data The multi channel analyser has an offset function for enhancing the energy resolution. It possesses the following features: Analogue output for observing heights of the pulse spectrum on an oscilloscope, A USB output for connecting to a computer, Integrated power supply for alpha detector pre-amp (909100.00), Integrated power supply for X-ray energy detector. Includes 1.5-m mains lead, USB cable type A/B Multi-channel analyser software (required) Resolution (per spectrum): up to 4096 channels (12 bit) Memory: unlimited Lag time: 60 µs Coincidence window: 1 µs Analogue input: negative pulse impedance: 3.3 kilohms, 150 pf Accessories Multi-channel analyser software (required) 13727-99 PHYWE Systeme GmbH & Co. KG www.phywe.com 15

Gamma Particles - Energy - Compton Effect P2524615 Photonuclear cross-section / Compton scattering cross-section with MCA Gamma-spectrum of 22 Na. The radiation of 137 Cs and 22 Na is measured with a scintillation detector and the energy spectrum determined with a multi channel analyser. The fractions of the spectra caused by Compton scattering and those caused by the photoelectric effect are determined on the basis of their areas. The results are used for determining the ratio of the effective cross-sections and examining its energy dependence. 1. Measurement of the g-spectra of 22 Na and 137 Cs, using a scintillation detector. 2. Determination of the ratio of the specific effective cross-sections due to the Compton effect and the photoelectric effect in photons having energy values of 511, 662 and 1275 kev. g-radiation Interaction with material Photoelectric effect Compton effect Pair formation Detection probability Scintillation detectors Gamma detector 09101-00 1 Multi channel analyser 13727-99 1 Radioactive source Cs-137, 37 kbq 09096-01 1 Operating unit for gamma detector 09101-93 1 Radioactive source Na-22, 74 kbq 09047-52 1 measure Software multi channel analyser 14452-61 1 Operating unit for gamma detector Operating unit for gamma-detector. Benefits Highly stabilized DC voltage continuously adjustable by 10 range potentiometer. Equipment and technical data Output / MHV socket: 600-1100 V DC. Stabilization: better than 0.1 %. Input voltage: 220 V AC. Dimensions (mm): 115 x 65 x 225. 09101-93 excellence in science 16

Counter tube characteristics Counter tube characteristics P2540010 Pulse rate as a function of the counter tube voltage. The counter tube uses the ionising effect of high-energy radiation in order to measure the intensity of the radiation. The counter tube characteristics describe its working range, i.e. the voltage range in which it reliably counts the incoming particles. Task Determine the counter tube characteristics of the type B counter tube that is used. Geiger-Mueller counter tube Quenching gas Characteristics Ionising radiation XR 4.0 expert unit 09057-99 1 XR 4.0 X-ray plug-in unit W tube 09057-80 1 Geiger-Mueller Counter tube, type B 09005-00 1 Best fitting XR 4.0 sets for this experiment: XRE 4.0 X-ray expert set 09110-88 XRP 4.0 X-ray Solid state physics upgrade set Geiger-Mueller counter tube, type B Self recovering Halogenid countertube for detection of Alpha-, Beta- und Gamma-radiation with Mica window. 09005-00 Geiger-Mueller Counter tube, 45 mm Purpose and description The Geiger-Mueller Counter tube, 45 mm is a self-extinguishing halogen counting tube for the detection of alpha, beta and gamma radiation. A long plateau (approx. 425...650V) with only a slight slope renders the selection of the operating point uncritical. The actual counting tube, which is mounted in a metal cylinder with a permanent BNC connecting cable, has a thinwalled metal sheath that is permeable to alpha radiation. Benefits Highly sensitive counting tube Useful to investigate weakly radioactive sources Even natural radioactive sources can be investigated. 09007-00 09120-88 PHYWE Systeme GmbH & Co. KG www.phywe.com 17

X-ray dosimetry P2541801 X-ray dosimetry Ionisation current I C as a function of the capacitor voltage U C for different diaphragm tubes. Dosimetry, as a subspecialty of medical physics, deals with the determination and calculation of dose rates, which is also of great importance in view of the radiation protection directives. This experiment demonstrates the principle of measurement and it explains the various units of absorbed dose, equivalent dose, and absorbed dose rate. Inside a plate capacitor, an air volume is irradiated with X-rays. The resulting ion current is used to determine the dosimetric data. 1. Using the two different diaphragm tubes and the fluorescent screen, the given distance between the aperture and the radiation source at maximum anode voltage and current is to be determined. 2. The ion current at maximum anode voltage is to be measured and graphically recorded as a function of the capacitor voltage by using two different beam limiting apertures. The ion dose rate and the energy dose rate are to be determined from the saturation current values. 3. Using the d = 5 mm aperture, the ion current is to be determined and graphically recorded at various anode currents but with maximum anode and capacitor voltages. 4. The ion current is to be measured and graphically recorded as a function of the capacitor voltage at different anode voltages and the corresponding saturation currents plotted graphically. X-rays; Absorption inverse square law Ionizing energy; Energy dose Equivalent dose and ion dose and their Rates Q factor; Local ion dose rate; Dosimeter XR 4.0 expert unit 09057-99 1 XR 4.0 X-ray plug-in unit W tube 09057-80 1 XR 4.0 X-ray fluorescent screen 09057-26 1 XR 4.0 X-ray optical bench 09057-18 1 XR 4.0 X-ray Capacitor plates f.x-ray-unit 09058-05 1 DC measuring amplifier 13620-93 1 Power supply, 0...600 VDC 13672-93 1 Best fitting XR 4.0 sets: XRE 4.0 X-ray expert set 09110-88 XRD 4.0 X-ray dosimetry upgrade set 09170-88 DC measuring amplifier Versatile measuring amplifier for measurement of very small direct currents, electrical charges and for quasi-static measurements of DC voltages. 13620-93 excellence in science 18

DİĞER NÜKLEER CİHAZLAR ÜRÜN PORTFÖYÜMÜZ NEL Elektronik Cihazlar İmalat ve Ticaret A.Ş. ANKARA Merkez Adres Tel Faks E-posta : Çetin Emeç Bulvarı 1324. Cadde No:39 A. Öveçler 06460 ANKARA : (312) 472 69 00 (10 hat) : (312) 472 69 79 : nel@nel.com.tr İSTANBUL Bölge Ofisi Adres Tel Faks E-posta : Kore Şehitleri Cad. No: 37 Daire 3-4 Esentepe Mah. Şişli 34394 İSTANBUL : (212) 275 84 00 : (212) 275 65 00 : istanbul@nel.com.tr www.nel.com.tr / www.nelegitimportali.com