PoS(FNDA2006)010 FAST NEUTRON DETECTORS BASED ON MICROMEGAS TECHNOLOGY. S. Andriamonje * I. Giomataris and J. Pancin

Similar documents
New neutron detector based on Micromegas technology for ADS projects

A new detector for neutron beam monitoring

Fission Fragment characterization with FALSTAFF at NFS

Neutron imaging with a Micromegas detector

FEASIBILITY STUDY OF NEW MICROSCOPIC FISSION CHAMBERS DEDICATED FOR ADS

Background optimization for a new spherical gas detector for very light WIMP detection

Neutrons for Science (NFS) at SPIRAL-2

Neutron capture and fission reactions on. sections, -ratios and prompt -ray emission from fission. 1 Introduction and Motivation

The Compact Muon Solenoid Experiment. Conference Report. Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

EEE4106Z Radiation Interactions & Detection

Present and Future of Fission at n_tof

DIRECT EXPERIMENTAL TESTS AND COMPARISON BETWEEN SUB-MINIATURE FISSION CHAMBERS AND SPND FOR FIXED IN-CORE INSTRUMENTATION OF LWR

Flux and neutron spectrum measurements in fast neutron irradiation experiments

Final report on DOE project number DE-FG07-99ID High Pressure Xenon Gamma-Ray Spectrometers for Field Use

Performance of high pressure Xe/TMA in GEMs for neutron and X-ray detection

arxiv: v1 [astro-ph.im] 6 Dec 2010

Neutronics Experiments for ITER at JAERI/FNS

PoS(TIPP2014)033. Upgrade of MEG Liquid Xenon Calorimeter. Ryu SAWADA. ICEPP, the University of Tokyo

arxiv: v3 [physics.ins-det] 19 Sep 2017

GEM at CERN. Leszek Ropelewski CERN PH-DT2 DT2-ST & TOTEM

Nuclear waste management

Precision neutron flux measurement with a neutron beam monitor

Precision Calibration of Large Area Micromegas Detectors Using Cosmic Muons

Total kinetic energy and fragment mass distributions from fission of Th-232 and U-233

MUSE-4 BENCHMARK CALCULATIONS USING MCNP-4C AND DIFFERENT NUCLEAR DATA LIBRARIES

Compton Camera. Compton Camera

Track Resolution Measurements for a Time Projection Chamber with Gas Electron Multiplier Readout

Advances in the Micro-Hole & Strip Plate gaseous detector

RADIOLOGICAL IMPACT OF THE TRIGAACCELERATOR-DRIVEN EXPERIMENT (TRADE)

Detecting low energy recoils with Micromegas

Measurement of the n_tof beam profile in the second experimental area (EAR2) using a silicon detector

CONCEPTUAL STUDY OF NEUTRON IRRADIATOR-DRIVEN BY ELECTRON ACCELERATOR

Light ion recoil detector

Nuclear Instruments and Methods in Physics Research A

New irradiation zones at the CERN-PS

Alpha-Gamma discrimination by Pulse Shape in LaBr 3 :Ce and LaCl 3 :Ce

CCD readout of GEM-based neutron detectors

Performance of a triple-gem detector for high-rate particle triggering

X-ray ionization yields and energy spectra in liquid argon

Neutrons For Science (NFS) at SPIRAL-2 (Part II: pulsed neutron beam)

Physics sources of noise in ring imaging Cherenkov detectors

Simulating the Charge Dispersion Phenomena in Micro Pattern Gas Detectors with a Resistive Anode

GEM-based photon detector for RICH applications

PHOTOELECTRON COLLECTION EFFICIENCY AT HIGH PRESSURE FOR A GAMMA DETECTOR ENVISAGING MEDICAL IMAGING

PoS(EPS-HEP2015)232. Performance of a 1 m 2 Micromegas Detector Using Argon and Neon based Drift Gases

Characterization of the 3 MeV Neutron Field for the Monoenergetic Fast Neutron Fluence Standard at the National Metrology Institute of Japan

Determination of the boron content in polyethylene samples using the reactor Orphée

Comparison of the Photo-peak Efficiencies between the Experimental Data of 137 Cs Radioactive Source with Monte Carlo (MC) Simulation Data

A Comparison between Channel Selections in Heavy Ion Reactions

Breakdown limit studies in high-rate gaseous detectors

PoS(Baldin ISHEPP XXII)065

DETECTORS. I. Charged Particle Detectors

Neutron and gamma ray measurements. for fusion experiments and spallation sources

Neutron cross-section measurements at the n_tof facility at CERN

Electron transparency, ion transparency and ion feedback of a 3M GEM

Gamma-ray Spectroscopy with LaBr 3 :Ce Scintillator Readout by a Silicon Drift Detector

CVD Diamond History Introduction to DDL Properties of Diamond DDL Proprietary Contact Technology Detector Applications BDD Sensors

This paper should be understood as an extended version of a talk given at the

He-3 Neutron Detectors

Beam diagnostics: Alignment of the beam to prevent for activation. Accelerator physics: using these sensitive particle detectors.

arxiv:physics/ v2 27 Mar 2001

arxiv:physics/ v1 3 Aug 2006

Measurement of the transverse diffusion coefficient of charge in liquid xenon

MONTE-CARLO SIMULATIONS OF TIME- RESOLVED, OPTICAL READOUT DETECTOR for PULSED, FAST-NEUTRON TRANSMISSION SPECTROSCOPY (PFNTS)

DEMIN: A neutron spectrometer, Micromegas-type, for inertial confinement fusion experiments

Estimation of 210 Po Losses from the Solid 209 Bi Target Irradiated in a Thermal Neutron Flux

CHARACTERISTICS OF LIGHT CHARGED PARTICLE EMISSION IN THE TERNARY FISSION OF 250 CF AND 252 CF AT DIFFERENT EXCITATION ENERGIES

Feasibility Studies for the EXL Project at FAIR *

DETERMINATION OF THE NEUTRON FISSION CROSS-SECTION FOR 233 Pa FROM 0.5 TO 10 MeV USING THE TRANSFER REACTION 232 Th( 3 He,pf) 234 Pa.

Fast Neutron and Gamma-Ray Detectors for the CSIRO Air Cargo Scanner

Journal of Radiation Protection and Research

Nuclear Cross-Section Measurements at the Manuel Lujan Jr. Neutron Scattering Center

A Time Projection Chamber for Precision ^^^Pu(n,f) Cross Section Measurement

Felix C. Difilippo. Oak Ridge National Laboratory P.O. Box 2008 Oak Ridge, TN 3783 l-6363 USA

ACTAR TPC: an active target and time projection chamber for nuclear physics

Shielded Scintillator for Neutron Characterization

Simulation of GEM-TPC Prototype for the Super-FRS Beam Diagnostics System at FAIR

ARTICLE IN PRESS. Nuclear Instruments and Methods in Physics Research A

Design and test of an Accelerator Driven Neutron Activator at the Joint Research Centre of the European Commission

THE USE OF GE DETECTORS FOR (N,XN) CROSS-SECTION MEASUREMENTS AT INTENSE AND LOW FREQUENCY PULSED NEUTRON BEAMS. Abstract

in2p , version 1-28 Nov 2008

Results from Silicon Photo-Multiplier neutron irradiation test

Micro Pixel Chamber with resistive electrodes for spark reduction

Discharge studies in Micromegas detectors in low energy hadron beams

Cavern background measurement with the ATLAS RPC system

Experimental verification of a gain reduction model for the space charge effect in a wire chamber

M.Cagnazzo Atominstitut, Vienna University of Technology Stadionallee 2, 1020 Wien, Austria

Development of New MicroStrip Gas Chambers for X-ray Applications

Waste Characterization

Drift plane. substrate (20ÉIm polyimide) 200ÉIm. Back strip (180ÉIm width) Base (Ceramic) Anode strip (10ÉIm width) Cathode strip (100ÉIm width)

CMS Note Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

Development of a neutron time-of-flight source at the ELBE accelerator

A novel large-volume Spherical Detector with Proportional Amplification read-out

Gas-filled Detectors

A Photofission Delayed γ-ray Spectra Calculation Tool for the Conception of a Nuclear Material Characterization Facility

Elastic Recoil Detection Method using DT Neutrons for Hydrogen Isotope Analysis in Fusion Materials. Abstract

Neutron capture cross section on Lu isotopes at DANCE

Transmutation of Minor Actinides in a Spherical

GEM: A new concept for electron amplification in gas detectors

arxiv: v1 [physics.ins-det] 4 Nov 2013

Transcription:

FAST NEUTRON DETECTORS BASED ON MICROMEGAS TECHNOLOGY S. Andriamonje * CEA-Saclay, DSM/DAPNIA F- 91191 Gif-sur-Yvette, France E-mail: sandriamonje@cea.fr I. Giomataris and J. Pancin CEA-Saclay, DSM/DAPNIA F- 91191 Gif-sur-Yvette, France E-mail: Ioanis.Giomataris@cern.ch and jpancin@dapnia.cea.fr After a short description of the Micromegas principle, a new concept of neutron detectors based on this technique is presented. The report is illustrated by an overall picture of the possible use of these detectors in different domain such as: nuclear physics, inertial fusion and industrial application. A particular description will be devoted to the compact detector named "Piccolo- Micromegas". This detector, able to measure neutron flux in a broad range of energy of neutron (from thermal to several MeV), is developed for the measurements of neutrons flux in-core of the future generations of the nuclear reactors (fast and possibly Accelerator Driven System (ADS)). International Workshop on Fast Neutron Detectors University of Cape Town, South Africa April 3 6, 2006 * Speaker Copyright owned by the author(s) under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike Licence. http://pos.sissa.it

1. Introduction Micromegas is a gaseous detector that has been developed initially for tracking in high rate high-energy experiments [1]. At present, Micromegas detector is used in many experiments [2,3] and due to its high performances is being employed for searching rare events such as the Solar axion CAST [4]. The detection principle is simple: the gas volume is separated in two regions by a thin micromesh, the first one where the conversion and drift of the ionization electrons, occur and the second one, 50-160 micron thick, where the amplification takes place. Ionization electrons are created by the energy deposition of an incident charged particle in the conversion gap. In the amplification region, a high field (40 to 70 kv/cm) is created by applying a voltage of a few hundred volts between the micromesh and the anode plane, which collects the charge produced by the avalanche process. The anode can be segmented into strips or pads. The positive ions are drifting in the opposite direction and are collected on the micromesh. One of the main advantages of Micromegas is its robustness and its high resistance to radiations. These qualities have been exploited to develop a new neutron detector and in particular for the use in nuclear reactor environment: operation with very high neutron flux, high gamma ray background and possibly at high temperature. After a description of the principle of the Micromegas for neutron detection, we give some examples of his application for neutron beam characterisation, for neutron tomography and for diagnostics of inertial fusion program. A special attention will be given in the description of the new detector dedicated for the measurement of neutron flux in-core of nuclear reactor. In order to be placed inside an empty rod of a reactor the detector needs to be compact, sealed and very small (3.5 cm x 3.5 cm x 3.5 cm), contrary to the usual Micromegas detector used in particle physics experiments hence the origin of the Piccolo-Micromegas name. The advantage of this detector over conventional neutron flux detectors and the results obtained with the first prototype with 14 MeV neutron source and inside a TRIGA reactor are presented. 2. Description of Micromegas for neutron detection The Micromegas technology has been extended to develop a new neutron detector [5,6]. As mentioned before the principle is based on the detection of the electron created by ionization of the filled gas by charged particles. In order to operate the Micromegas detector as a neutron detector, appropriate neutron/charged particle converter must be employed which can be either the detector's filling gas or target with appropriate deposit on its entrance window. Inter-dependent parameters such as the high neutron reaction cross section, the low charged particles energy loss inside the converter, their subsequent energy-angular distribution and the range inside the filling gas has been considered and optimised. 2

An appropriate neutron/charged particle solid converter has been chosen ( 6 Li(n,α) and 10 B(n,α)) for neutron energy up to 1 MeV. The main advantage of the solid converter concept is a great simplicity of the structure and especially the excellent spatial (<50 µm) and time resolution (~ ns) that is obtained by using small drift gaps. Such performance is not easy to obtain using gaseous converters, for instance 3 He. The draw back is the lower efficiency of the thin solid converter for thermal neutrons, limited by the neutron (n,α) cross section and the thickness of the 6 Li layer, which must be shorter than the alpha particle range. However, Monte Carlo calculations show that an optimal thickness of 120 µm ( 6 Li target) is required in order to obtain an efficiency of about 25% for thermal neutrons at room temperature. 2.1 Micromegas detector for CERN n_tof beam profiler One of the first application of Micromegas for neutron detection is the determination of the characteristics of the n_tof neutron beam at CERN [7]. Since the neutron energy range of the n-tof facility extends from 1 ev to 250 MeV, there is not a unique choice of an efficient converter. The combination of (n,α) reaction and elastic scattering on the filling gas of the detector has been used for the determination of the neutron beam profile of the n_tof facility at CERN. The main characteristics of the n_tof detector and results can be fund in reference [7]. In summary the principle is shown in Figure 1a), the neutron/charged particle converter employed are: ( 6 Li(n,α) for neutron energy up to 1 MeV and H(n,n )H and 4 He(n,n ) 4 He for high energy neutron) which are the detector's filling gas. The anode strips (50 in total) have a pitch of 1.5 mm and are separated by 100 µm gaps and connected on a fast current preamplifier with a rise time of 1 ns associated with an innovative Data Acquisition System based on 1 GHz flash ADC with a rate of 180 MHz. a) b) Figure 1: a) The principle of Micromegas for neutron detector used in n_tof experiment [7] b) Schematic view of the n_tof Micromegas chamber In order to achieve a very good profile of the n_tof beam, the Micromegas detector has been placed in the vacuum chamber (Figure 1b) under the standard pressure of the n_tof tube (10-3 bar). The main characteristics of this detector is the choice of material having a minimum 3

influence on the high energy neutron. The example described here can be extended for other applications such as the diagnostic of the neutron beam for boron therapy [8] or hadron therapy [9]. 2.2 Micromegas detector for Inertial Confinement Fusion (ICF) experiments The development of Micromegas has extended recently by M. Houry et al [10] for a new neutron diagnostic to achieve high energy neutron spectroscopy in large gamma background. This is the situation in the inertial confinement fusion (ICF). The concept of the detector is based on the association of a Micromegas detector with a solid neutron/charged particle converter. The DEMIN (DEtector MIcromegas for Neutron) detector is made of a neutron/charged particle conversion foil set in front of a Micromegas detector. The interaction of fast neutron in the neutron/charged particle converter produces charged particle which may be detected by the Micromegas detector. The principle of the concept is similar to the n_tof Micromegas detector based on the detection of the recoil charged particle but the origin is not the same. For n_tof it is from the filling gas. In DEMIN case, the neutrons also interact in the gas, but considering the difference of atomic density between the neutron/charged particle converter and the gas this second process is negligible. The schematic view of the DEMIN concept from reference [10] is reported in Figure 2. It shows in the figure the different thickness of the constituent of the detector: 2 mm for the polypropylene (CH 2 ) neutron/charged particle converter, 0.6 mm for the gaseous detector (0.5 mm thick for the upper part and 0.1 mm for the bottom part). Figure 2: Schematic view of the DEMIN diagnostic. Ionization electrons are produced along the path of scattered protons and drift between the conversion foil and the epoxy substrate. On the other hand, electrons produced by γ-rays go through the gaps with a low ionization probability [10]. The thickness of the gas has been chosen thin enough to limit ionization by recoil electrons. Detailed description of the DEMIN detector and the experiments can be found in reference [10]. In summary, studies have been performed with a neutron generator and gamma-ray sources and it has been shown that 14 MeV neutrons can be detected with improved efficiency and relative gamma insensitivity. This low gamma sensitivity makes this concept appealing for inertial fusion experiments. 4

2.3 Other Micromegas development for fast neutron detection The n_tof Micromegas detector has been modified for the detection of fast neutrons from induced photofission [11]. A thin foil 12 µm of polypropylene and the filling gas are used for neutron/charged particle converter. The development is for the characterisation of the radioactive parcel of nuclear waste. The method consists in an irradiation of the radioactive parcel by photons in order to create photofission reactions of the actinides present within the parcel. The detection of the fast neutron associated with fission could permit the determination of the quantity of the actinides contained in the waste panel. In this project the main quality of the needed detector is its very small sensitivity of high flux of gamma background. The experiment performed at Ghent University facility shows that Micromegas detector meets this requirement. The Oak Ridge group [12] has also developed a new neutron detector based on Micromegas technology. The principle of the detector is quite similar to the one used for the n_tof experiment ( 6 Li and 10 B are used for neutron/charged particle converter) but the technical fabrication is different for example the use of a quartz substracte using microfabrication techniques. The interesting work is the development of sealed 2D Micromegas detector which is very useful not only for the characterisation of the future neutron spallation source but also for other applications. 3. Piccolo-Micromegas for neutron flux measurements in-core of nuclear reactor 3.1 Motivation Fast nuclear reactors and Accelerator Driven Systems (ADS) are considered as an alternative for energy production and transmutation of nuclear wastes. One important step needed for approval of a demonstrator is the experimental validation of simulations. Of particular interest is the determination of the neutron spectrum (i.e neutron flux as a function of the neutron energy) for different configurations of the subcritical device. As well known, the neutron flux in ADS consists of neutrons produced via spallation reactions in the target and fissions from the multiplying blanket. Unfortunately the neutron spectra cannot be measured using only one type of detector. To cover the complete energy range of the produced neutrons, a new neutron detector concept based on Micromegas technology has been developed. For illustration the possible subcritical configuration based in TRIGA-ADS project which consists of coupling a 1 MW TRIGA reactor with a 140 MeV proton accelerator has been chosen [13]. The core has a cylindrical shape, the fuel rods being arranged in seven concentric rings labeled A to G. The central rod and the rods named ring B are reserved for the spallation target and its cooling system. The measurement can be only achieved starting from ring C. The 5

distribution of neutrons in three-dimensional space as a function of energy and time is simulated using innovative simulation codes (FLUKA and EA-MC [14,15] at CERN, and MCNP-4C [16] at ENEA/Casaccia). An example of the neutron energy spectrum for different regions of the core for k src = 0.97 is given in Figure 4b. The measurement of neutron flux spectra is a necessary step in order to characterize the neutronics of the system. a) b) Target in central position Fuel elements withdrawn (1ring) Figure 4: a) Example of the configuration of the TRIGA-ADS project b) Neutron flux spectra at selected locations of the TRIGA-ADS reference configuration [13]. 3.2 The principle of Piccolo-Micromegas The advantages of Micromegas over conventional neutron detector, described in the preceding paragraphs are used to extend the development for the measurement of neutron flux in a nuclear reactor core. Fissile elements such as 235 U, 232 Th are used simultaneously as neutron/charged particle converter in addition to 10 B and recoil ions of the gas (Ar + ic 4 H 10 quencher) filling the detector. The Piccolo-Micromegas detector shown in Figure 5a is designed to cope with severe constraints encountered in a nuclear reactor environment (high radiation, high temperature, neutron activation, sealed detector). For this reason the detector structure, frames and sensitive elements have been carefully chosen and most of them are made out of stainless steel and ceramics. The detector consists of a drift electrode, a thin stainless steel cathode grid and four anode pads connected to fast amplifiers. The drift gap is 1 mm wide and the amplification gap 160 µm. In a second prototype, different amplification gaps were used in each compartment, in order to adapt the dynamic range of the collected charge. Because of the high reactor temperature and the high radiation yield, the electronics were placed outside and connected to the anode pads through special radiation hardened and low capacitance coaxial cables 10 meter long. The drift electrode is composed of four neutron/charged particle converters: 10 B for thermal and epithermal neutrons, 235 U for monitoring as the fission cross section of 235 U from thermal energies up to several MeV is well known, 232 Th with a fission threshold of about 1 MeV is dedicated to high energy neutrons. The elastic scattering of neutrons with light atoms 10 11 10 10 10 9 10 8 Ring E Ring C Tantalum target Ring B 10 7 10-3 10-2 10-1 10 0 10 1 10 2 10 3 10 4 10 5 10 6 10 7 Neutron energy (ev) 6

Micromegas a fast neutron detector from the gas filling the detector (hydrogen) will produce nuclear recoils than could be detected with a typical threshold of several kev. a) b) the TRIGA reactor Using four converters with a unique detector will permit extracting practically on line a large range of the neutron flux spectrum in a specific position in the reactor. The large dynamic range of Piccolo-Micromegas will permit precise measurements and a detailed scanning of the flux into the whole reactor volume. At very high counting rate (>100 MHz) measurement will be performed on a current mode basis. At low counting rate, the fast response of the detector will allow counting one by one the incident particles using a low noise fast-preamplifier. It opens the way to measure the neutron flux at the peripheral part of the reactor and also in some cases when the full reactor power is not used. 3.3 Tests and measurements with the first prototype with 14 MeV neutron source 10 a) 5 0-5 -10-15 -20-25 electrons -30-35 -40-600 -400-200 140 Counts/0.25 mv Amplitude (mv) A first test with sealed prototype of the detector has been performed with 14 MeV neutrons given by the Cadarache CELINA facility. ions 100 80 200 400 600 Rate = 4.15 fissions/s 60 40 20 0 0 b) 120 0 20 40 60 80 100 120 Amplitude (mv) Times (ns) Figure 6: a) Example of the fission fragment pulse b) Amplitude spectrum of fragments 7 235 U fission Figure 5: a) Schematic view of the principle of Piccolo-Micromegas detector (in horizontal position) for neutron flux measurement, b) View of the Piccolo-Micromegas assembly placed inside

An example of the pulse obtained from the fission fragment emitted in the interaction of neutrons with 235 U is shown in figure 6a). This figure shows clearly the contribution of the detected electrons (fast part of the pulse) and ions (slow part) with a total width of 150 nsec. An example of the spectrum of 235 U fission fragment as a function of the amplitude of the pulse is reported in figure 6b). A full simulation of the Piccolo-Micromegas detector placed inside the CELINA-Cadarache neutron source facility has been performed using FLUKA code [14]. The study has been centred on the particular case of 235 U, because of the well-known fission cross section. For 50 µg of 235 U the measured fission rate given in figure 6b) is in good agreement with the prediction (4 fissions/s). 3.4 Tests and measurements with the first prototype in 1 MW TRIGA reactor A second test with sealed prototype placed inside an empty rod of the reactor has been performed in-core of the TRIGA reactor of ENEA at Casaccia (Italy). The detector was placed inside of a sealed long stainless tube having the same dimension of the reactor empty rod; usual BNC cables have been used and placed inside a 10 m watertight stainless tube (see Figure 5b). The measurement has been performed at two positions of the detector, at the periphery and in the centre of the reactor. The characteristics of Piccolo-Micromegas (gain, field of the drift and ageing) per simultaneous measurement of the currents and the counting rates according to the power of the reactor were studied in detail. The preliminary results confirm that the detector such as it is conceived, is able to measure neutron flux from thermal to several MeV in the very aggressive environment of a reactor. It is possible with Micromegas to count event per event, the choice of the gain makes it possible to distinguish the neutrons of the gamma background. A linearity (10% to 5%) of the neutron flux according to the power of the reactor has observed. Counting alpha, of radioactivity of 235 U before and after high power irradiation, seems to show that at the end of 10 days of operation in sealed condition, it was not observed of notable degradation of the detector. 4. Conclusion The Micromegas technology already used for particle physics experiment has extended to develop a new neutron detector generation. The example reported in this paper show the ability of this type of neutron detector to operate in different environment conditions: in the air, in the vacuum, in the water. As shown in this paper the new Piccolo-Micromegas can work in nuclear reactor, which is a very aggressive experimental condition. Using four converters with a unique detector will permit to extract practically one line a large part of the neutron flux spectrum in dedicated position in the reactor. The ability of this type of detector to detect the high-energy neutron (via nucleus recoil detection) permit also to 8

use it to monitor the impact of the proton beam on the spallation target for the ADS project. Such a system is very useful for safety. Piccolo-Micromegas detector was studied for a particular case in the TRIGA-ADS project [13], but could be used in other applications for instance in actual or future generation nuclear reactors. Thanks to the innovative techniques used, the prototype detector actually designed and manufactured seems to meet the conditions for a correct operation in reactor. Acknowledgment The work related to Piccolo-Micromegas has been performed with the collaboration of: S. Aune, A. Giganon, M. Riallot (CEA Saclay DSM/DAPNIA 91191 Gif-sur-Yvette, France), C. Blandin, S. Breaud, B. Geslot, C. Jammes (CEA/DEN/ Cadarache, 13108 Saint-Paul Lez Durance-France), Y. Kadi, L. Sarchiapone (CERN CH 1211 Geneva-Switzerland), G. Ban, P. Laborie, J.F. Lecolley, J.C. Steckmeyer, J. Tillier (LPC - CNRS/IN2P3 - ENSICAEN - UCBN, 6 bd Maréchal Juin, 14050 Caen, France),R. Rosa (ENEA-Casaccia, Via Anguillarese, 00060 Roma, Italy), G. Andriamonje (IXL - Université Bordeaux 1 F- 33405 Talence Cedex, France) References [1] I. Giomataris et al., A high-granularity position sensitive gaseous detector for high particle-flux environments, Nucl. Instrum. Methods A 376 (1996) 29. [2] I. Giomataris, Nucl. Instr. and Meth. A 419 (1998) 239. [3] G. Charpak et al., Nucl. Instr. and Meth. A 478 (2002) 26. [4] K.Zioutas et al., Phys. Rev. Letters, 94, 121301, (2005) [5] S. Andriamonje et al., Nucl. Instr. Meth. A 481 (2002) 36 [6] S. Andriamonje et al., Advances in Neutron Scattering Instrumentation. Proceedings of SPIE, Volume 4785, Ian S. Anderson, Bruno Guýrard, Editors, November 2002, pp. 214-225 [7] J. Pancin, et al., Nucl. Instr. and Meth. A 524 (2004) 102 [8] P. Mandrillon, private communication [9] J. Remillieux, private communication [10] M. Houry et al., DEMIN: a neutron spectrometer, Micromegas-type, for inertial confinement fusion experiments, Nucl. Instrum. Methods A 557 (2006) 648. [11] S. Boyer et al., A fast Neutron Detector for Nuclear Waste Characterization Proceeding of GLOBAL 2005 Tsukuba, Japan (2005) Paper No. 303 [12] C.L. Britton et al., A Detector for Neutron Imaging IEEE (2004) 360 [13] The TRADE Working group, TRiga Accelerator Driven Experiment (TRADE) Feasibility Report. ENEA Report, March 2002. [14] A. Fasso, et al., Intermediate Energy Nuclear Data: Models and C, Proceedings of a Specialist s Meeting, Issy les Moulineaux (France) 1994 [15] C. Rubbia, et al., Conceptual Design of a Fast Neutron Operated High Power Energy Amplifier, CERN/AT/95-44 (EET) Geneva, September 29, 1995. Y. Kadi, et al., The EA-MC Monte Carlo Code Package, in Proc. of the 5th Int. Meeting on Simulating Accelerator Radiation Environment SARE-5: Models and Codes for Spallation Neutron Sources, Paris, France, July 17-18, 2000. [16] J. F. Briesmeister, Editor A MCNP TM, General Monte Carlo N-Particle Transport Code, Version 4C, Los Alamos National Laboratory report LA-13709-M, March 2000). 9