Novel Plastic Microchannel-Based Direct Fast Neutron Detection

Similar documents
Novel Fast Neutron Counting Technology for Efficient Detection of Special Nuclear Materials

Exploring the spatial resolution of positionsensitive microchannel plate detectors

Pulsed Neutron Interrogation Test Assembly - PUNITA

High-Resolution Gamma-Ray and Neutron Detectors For Nuclear Spectroscopy

Lecture 16 Light transmission and optical detectors

Measurements of liquid xenon s response to low-energy particle interactions

Performance of the MCP-PMT for the Belle II TOP counter

PoS(PD07)020. Timing Properties of MCP-PMT. Kenji Inami. Nagoya university, Nagoya, Japan

DETECTORS. I. Charged Particle Detectors

CCD readout of GEM-based neutron detectors

LAAPD Performance Measurements in Liquid Xenon

Neutron Induced Nuclear Counter Effect in Hamamatsu Silicon APDs and PIN Diodes

EEE4106Z Radiation Interactions & Detection

Scintillation Detector

A gas-filled calorimeter for high intensity beam environments

A New Microchannel-Plate Neutron Time-of-Flight Detector

Quality Assurance. Purity control. Polycrystalline Ingots

X-ray spectrometry with Peltier-cooled large area avalanche photodiodes

Energetic particles and their detection in situ (particle detectors) Part II. George Gloeckler

Flux and neutron spectrum measurements in fast neutron irradiation experiments

Elastic Recoil Detection Method using DT Neutrons for Hydrogen Isotope Analysis in Fusion Materials. Abstract

arxiv:physics/ v1 3 Aug 2006

JRC Place on dd Month YYYY Event Name 1

REFERENCE SOURCES FOR THE CALIBRATION OF THE AUTOCORRELATION SINGLE-CRYSTAL SCINTILLATION TIME SPECTROMETER

Gamma Spectroscopy. References: Objectives:

a monte carlo simulation of photomultiplier resolution

Design, Construction, Operation, and Simulation of a Radioactivity Assay Chamber

Efficiency of modern large-area photo-detectors

High quantum efficiency S-20 photocathodes for photon counting applications

Direct WIMP Detection in Double-Phase Xenon TPCs

hν' Φ e - Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous?

Background Characterization and Rejection in the LZ Detector. David Malling Brown University IDM 2012 July 25, 2012

The relevance of XENON10 constraints in this low-mass region has been questioned [15] C.E. Aalseth et al. arxiv: v1

XENON Dark Matter Search. Juliette Alimena Columbia University REU August 2 nd 2007

Measurement of nuclear recoil responses of NaI(Tl) crystal for dark matter search

arxiv:astro-ph/ v1 15 Feb 2005

Radioactivity and Ionizing Radiation

PHOTODETECTORS AND SILICON PHOTO MULTIPLIER

arxiv: v2 [physics.ins-det] 8 Feb 2013

Performance of high pressure Xe/TMA in GEMs for neutron and X-ray detection

Factors Affecting Detector Performance Goals and Alternative Photo-detectors

EXPERIMENTS CHARACTERIZING THE X-RAY EMISSION FROM A SOLID-STATE CATHODE USING A HIGH-CURRENT GLOW DISCHARGE

DIGITAL PULSE SHAPE ANALYSIS WITH PHOSWICH DETECTORS TO SIMPLIFY COINCIDENCE MEASUREMENTS OF RADIOACTIVE XENON

Radiation Detection and Measurement

arxiv: v1 [physics.ins-det] 3 Feb 2011

STUDY ON THE ENERGY RESPONSE OF PLASTIC SCINTILLATION DETECTOR TO MEV NEUTRONS ABSTRACT

POSITION SENSITIVE DETECTION OF CONCEALED SUBSTANCES EMPLOYING PULSED SLOW NEUTRONS

Gamma-ray Spectroscopy with LaBr 3 :Ce Scintillator Readout by a Silicon Drift Detector

Scintillation Detectors

SCINTILLATION DETECTORS AND PM TUBES

arxiv: v1 [physics.ins-det] 16 May 2017

Chapter 4 Scintillation Detectors

PoS(ICHEP2016)474. SoLid: Search for Oscillations with a Lithium-6 Detector at the SCK CEN BR2 reactor

Energy response for high-energy neutrons of multi-functional electronic personal dosemeter

EXPERIMENTAL STUDY OF NEUTRON FIELDS PRODUCED IN PROTON REACTIONS WITH HEAVY TARGETS. Nuclear Physics Institute AS CR, Rez Czech Republic

Light ion recoil detector

Comments on the possible observation of d-d fusion in sonoluminescence (Reference-31 in Taleyarkhan et al. [2002] 1 )

Determination of the timing properties of a pulsed positron lifetime beam by the application of an electron gun and a fast microchannel plate

Nuclear Physics Laboratory. Gamma spectroscopy with scintillation detectors. M. Makek Faculty of Science Department of Physics

Digital imaging of charged particle track structures with a low-pressure optical time projection chamber

A new detector for neutron beam monitoring

Beam diagnostics: Alignment of the beam to prevent for activation. Accelerator physics: using these sensitive particle detectors.

A novel atomic layer deposition method to fabricate economical and robust large area microchannel plates

New Scintillators for the Border Monitoring Equipment

SNM detection by means of thermal neutron interrogation and a liquid scintillation detector

Chapter 11: Neutrons detectors

Introduction to Environmental Measurement Techniques Radioactivity. Dana Pittauer 1of 48

PoS(idm2008)010. The PICASSO Dark Matter Search Project. A. Davour for the PICASSO collaboration Queen s University

A Comparison between Channel Selections in Heavy Ion Reactions

MEASUREMENT OF THE D-D NEUTRON GENERATION RATE BY PROTON COUNTING

Introduction to neutron rem meters

Measurements of Neutron Total and Capture Cross Sections at the TOF spectrometers of the Moscow Meson Factory

Background simulations and shielding calculations

Observation of Reactor Antineutrinos at RENO. Soo-Bong Kim for the RENO Collaboration KNRC, Seoul National University March 29, 2012

Scintillation efficiency measurement of Na recoils in NaI(Tl) below the DAMA/LIBRA energy threshold

Study of radiation damage induced by 82 MeV protons on multipixel Geiger-mode avalanche photodiodes

Single Channel Beta-Gamma Coincidence Detection of Radioactive Xenon Using Digital Pulse Shape Analysis of Phoswich Detector Signals

arxiv: v1 [physics.ins-det] 29 Jun 2011

Chung-Yao Fellowship 2016 interview

Radiation Detection. 15 th Annual OSC Readiness Training Program.

Fast Neutron and Gamma-Ray Detectors for the CSIRO Air Cargo Scanner

A Measurement of Monoenergetic Neutrons from 9 Be(p,n) 9 B

Neutron cross-section measurements at the n_tof facility at CERN

Measurement of the transverse diffusion coefficient of charge in liquid xenon

David B. Cassidy. Department of Physics and Astronomy, University of California, Riverside, USA. Varenna, July 09

XMASS: a large single-phase liquid-xenon detector

HIGH-THROUGHPUT RADIATION DETECTION SYSTEMS

Introduction to Radiological Sciences Neutron Detectors. Theory of operation. Types of detectors Source calibration Survey for Dose

Setup for an in-situ measurement of the total light extinction of Liquid Argon in GERDA

Cherenkov Detector. Cosmic Rays Cherenkov Detector. Lodovico Lappetito. CherenkovDetector_ENG - 28/04/2016 Pag. 1

He-3 Neutron Detectors

Fast Neutron Induced Nuclear Counter Effect in Hamamatsu Silicon PIN Diodes and APDs

Spatial distribution of electron cloud footprints from microchannel plates: Measurements and modeling

Measurements of the Minimum Bending Radius of Small Diameter Scintillating Plastic Fibres

CALIBRATION OF SCINTILLATION DETECTORS USING A DT GENERATOR Jarrod D. Edwards, Sara A. Pozzi, and John T. Mihalczo

Understanding the response of LXe to electronic and nuclear recoils at low energies

Alpha-Energies of different sources with Multi Channel Analyzer

Measurement of 39 Ar in Underground Argon for Dark Matter Experiments

GEM: A new concept for electron amplification in gas detectors

arxiv:physics/ v1 [physics.ins-det] 14 Feb 2005

Transcription:

Novel Plastic Microchannel-Based Direct Fast Neutron Detection D. Beaulieu, P. de Rouffignac, D. Gorelikov, H. Klotzsch, J. Legere*, J. Ryan*, K. Saadatmand, K. Stenton, N. Sullivan, A. Tremsin Arradiance Inc., Sudbury MA * UNH EOS, Durham, NH Arradiance Inc. 142 North Road, Suite F-15 Sudbury, MA 1776 (8) 659-297 Tel and Fax www.arradiance.com 28 Arradiance Corporation. All rights reserved.

Outline Microchannel plate (MCP) background Arradiance functional thin film technology Atomic Layer Deposition (ALD) Substrate independent MCP technology Secondary electron emissive films Conductive films Fast neutron MCP detector Concept Functionality Simulation Fast neutron MCP detector experimental Fast neutron MCP detector results Summary and Future Work 2 28 Arradiance Corporation. All rights reserved. Confidential and Proprietary

MicroChannel Plate (MCP) Technology Mature (196s) MFG, Expensive, Bulk materials determine performance, High Z content, limited size (<1cm), difficult process control Event counting: >1 7 gain, <.1 c/cm 2 -s noise, high efficiency, <1µm spatial resolution, <5ps rms temporal resolution A. S. Tremsin, et al., Nucl. Instr. Meth. A 58, pp.853-857 (27) Wiza, Nuclear Inst. & Meth., Vol 162, 1979, 587 3 28 Arradiance Corporation. All rights reserved. Confidential and Proprietary

ALD MCP Technology MCP performance tied to glass composition ALD: Device optimization is decoupled from substrate. Semiconductor processes & process control. Materials engineering at the nanoscale Functional films composed of abundant,non-toxic materials. Advantages: High conformality (>5:1) Scalable to large areas Digital thickness control Pure films Control over film composition Low deposition temperatures (5-3 C) A Vapor inlets B Deposition region Alternating layers Thin film growth that relies on self-limiting surface reactions Gas A reacts with a surface excess precursor & reaction byproduct removed. Gas B is introduced to the evacuated chamber reacts with surface bound A excess precursor & reaction byproduct removed. Repetition of A B pulse sequence to build film layer-bylayer 4 28 Arradiance Corporation. All rights reserved. Confidential and Proprietary

ALD Functional Films: Substrate Independent MCP SE yields >5 possible vs MCP < 3 Conductivity range > 7 orders of magnitude Ohmic conduction, Stable in applied E field, TCR < 1% 1 35 http://www.mc-set.com/bse/mat_list.htm Gain 1 1 1 3 25 2 15 R (M ) 1 Gain Resistance 1 5 1 5 6 7 8 9 1 MCP bias (V) 1 µm pore, Soda Lime glass substrate, 4:1 L/D, R~28 MW 5-1x gain increase vs. commercial MCPs 5 28 Arradiance Corporation. All rights reserved. Confidential and Proprietary

Fast Neutron Detection Technology Fast Neutron Hydrogen-rich PMMA MCP Graded Temperature ALD Active films deposition at 14C Proton initiated electron cascade Output pulse 1 3 1 6 electrons Standard readout electronics Recoil Proton Secondary Electrons V 1 V 2 1kV, ultra low current Counts 7 6 5 4 3 2 1 1μs per UV power supply specs -7-6 -5-4 -3-2 -1 Time, ms Timing histogram of events detected under 12Hz-modulated UV illumination. 6 28 Arradiance Corporation. All rights reserved. Confidential and Proprietary

Fast Neutron Detection Simulation: P1 and P2 Probabilities P1 probability.7.6.5.4.3.2.1 P1 P detection = P 1 * P 2 * P 3 P 1 n-p recoil within the MCP substrate P 2 proton escape into MCP pore P 3 electron avalanche is formed (MCP ~1) P2 Pores are 5 m En = 2MeV 1 2 3 4 5 6 Wall thickness ( m) P2 probability 1.9.8.7 2 MeV neutron, 5 um pores.6.5.4.3.2.1 1 2 3 4 5 6 Wall thickness ( m) P1 x P2 probability.14.12.1.8.6.4.2.14 P1*P2*P3 Pores are 5 m En = 2 MeV 1 2 3 4 5 6 Wall thickness ( m).25 1.9.12 P1 probability.2.15.1.5 Pores are 5 m En = 1MeV P2 probability.8.7.6.5.4.3.2.1 1 MeV neutron, 5 um pores P1 x P2 probability.1.8.6.4 Pores are 5 m En = 1 MeV 1 2 3 4 5 6 1 2 3 4 5 6.2 Wall thickness ( m) Wall thickness ( m) 1 2 3 4 5 6 7 28 Arradiance Corporation. All rights reserved. Wall thickness Confidential ( m) and Proprietary

Fast Neutron Detection Simulation: P3 Probability and Event Timing Neutron Detection Stage Signal Amplification Stage Note: P3 Probability for Amplification Stage is 1. Timing for Amplification Stage is < 2 ps Operating at 12V Bias (Average Gain 47) P3 - Probability.9 for 1:1 LD 5 um Pores For 99.9% of events, we should expect a pulse timing uncertainty in coincidence mode of operation of ±1.5 ns For 9% of events, we should expect a pulse timing uncertainty in coincidence mode of operation of < ± 1. ns 8 28 Arradiance Corporation. All rights reserved. Confidential and Proprietary

Detector Hardware Experimental Setup 2 & 5 mm PMMA MCP, ~5 µm pores, 2 µm walls, 5 o bias angle installed above a chevron stack of 5:1 L/D MCPs Phosphor screen readout Canberra preamp and postamplifier H-rich MCP Pb-glass MCP Chevron Readout 9 28 Arradiance Corporation. All rights reserved. Confidential and Proprietary

Photons Isotope Sources: Experimental Setup Gamma (kev) Am-241 Cs-137 C-6 Cf-252 1.9 mq 76 Q 43.7 Q 36% @ 6, 38% @ 12-22 661 1.17; 1.33 Flux MCP/s 1.76x1 5 7.3x1 4 8.8x1 3 ~1 7 Isotopes ~15cm from liquid scintillator detector spectra collected over 11s (real time). Mesytec MPD-4. is used to record PMT data 1 9 Am241 8 7 6 5 4 3 2 1 1 196 391 586 781 976 1171 1366 1561 1756 1951 Gain Pb Reduction of flux by filters Gamma Neutron.251328.778787 Photons 1 9 Cs137 8 7 6 5 4 3 2 1 1 196 391 586 781 976 1171 1366 1561 1756 1951 Gain Wax Gamma Neutron.697481.384746 No filters 1 9 Cf-252 8 7 6 5 4 3 2 1 1 196 391 586 781 976 1171 1366 1561 1756 1951 Gain 1 28 Arradiance Corporation. All rights reserved. Confidential and Proprietary Photons 1 Pb Photons Photons 1 9 Cf-252 1"Pb 8 7 6 5 4 3 2 1 1 196 391 586 781 976 1171 1366 1561 1756 1951 Gain 2.5 Wax 1 9 Cf-252 2.5"Wax 8 7 6 5 4 3 2 1 1 196 391 586 781 976 1171 1366 1561 1756 1951 Gain

Gamma Isotope Sources MCP Results Summary Counts 1 1 1 Co-6 Am Cs-137 isotopic sources Gamma E (ev) QE 1 4.E+4 9.26E-5 6.61E+5 2.6E-3 1 2 4 6 8 1.2E+6 5.22E-3 Gain (ADC Volts) PMMA, 2mm, > 1k 5 µm Pores, 2µm wall.6.5.4 2mm PMMA MCP, 5V bias QE.3.2.1.E+ 5.E+5 1.E+6 1.5E+6 Gamma energy (ev) 11 28 Arradiance Corporation. All rights reserved. Confidential and Proprietary

Cf-252 MCP Experimental Results Summary Counts in 96 seconds detected by PMMA MCP only (chevron subtracted) 1 1 5V-V 5V-V 1 5V-V 1 5V-V Counts 1 1 1 No filter 2 4 6 8 Gain (ADC Volts) Counts 1 1 1" Pb 2 4 6 8 Gain (ADC Volts) Filter Count rate (cps/detector) no 125 1 Pb 52 2.5 wax 83 QE =.885 n QE = 3.28E-3 n QE well matched to simulation Gain (ADC Volts) 12 28 Arradiance Corporation. All rights reserved. Confidential and Proprietary Counts 1 1 1 1 1 2.5" Wax 5V-V 2 4 6 8

D-T Source (Thermo 32) Experimental Setup Polyethylene shielding around the source Filters: Lead (2 ), polyethylene (1, 2 ), borated plastic (1 ) Lead shielding around the detector Source ~3 cm MCPs 5 mm PMMA MCP, ~5 µm pores, 2 µm walls, 5 o bias angle installed above a chevron stack of 5:1 L/D MCPs 13 28 Arradiance Corporation. All rights reserved. Confidential and Proprietary

D-T Source Experimental Results Summary Predicted QE ~.8% P1xP2.18.16.14.12.1.8.6.4.2 5 1 15 2 Neutron energy (MeV) Conclusions: 1. QE to 14 MeV neutrons is ~1.2% 2. Believe n and counts are comparable at source settings 3. Timing better than 1.5 s (measurement limited by the source) 4. MCP dark count very low (~.3 c/cm 2 /s) 14 28 Arradiance Corporation. All rights reserved. Confidential and Proprietary

Conclusions and Future Work Functional films Improved performance, substrate independence Emissive Layer - Optimized SE yield and tailored conductivity Conductive layer - Ohmic conduction, Low TCR First Plastic MCP results demonstrated Fast neutron detector demonstration > 1% Neutron detection simulation target 2mm MCP QE=.3 5mm MCP QE=.12 <.1% Gamma detection simulation target Energy dependence QE=9.26x1-5 5.22x1-3 Future Work Optimization for Neutron QE > 1% Gamma Sensitivity Energy Sensitivity < 5 kev Demonstrate timing < 1.5ns 15 28 Arradiance Corporation. All rights reserved. Confidential and Proprietary

Acknowledgements Prof. James Ryan Dr. Richard Lanza 16 28 Arradiance Corporation. All rights reserved. Confidential and Proprietary