Ventilating grilles, Ventilating valves

Similar documents
Slot diffusers. Slot diffusers, Round duct diffusers. Slot diffusers. Slot diffusers LD-13, LD-14

Ventilating grilles, Ventilating valves

Swirl diffusers, Variable swirl diffusers

Variable swirl diffusers

Swirl diffusers, Variable swirl diffusers Swirl diffusers

Grille. Min. - max. dimensions

Nozzles. About Lindab. Comfort and Design. Product overview / symbols. Theory. Ceiling diffusers. Ceiling diffusers - visible.

Ceiling Diffuser. Type ADLR with circular face. Type ADLR-Q with square face 2/16/EN/8

GTH. Rectangular double deflection grille QUICK FACTS

Circular duct grille

SWIRL DIFFUSERS SWIRL DIFFUSERS OD-8

Krantz. Radial slot outlet with square blade array RL-Q2... circular blade array RL-R2... Air distribution systems DS 4186 E 09.

Krantz Components. Twist outlet DD-N... for ceiling installation. Air distribution systems

Circular duct grille. Dimensions. Description. Maintenance The grille should be removed to gain access to the duct.

Nozzle diffuser. Dimensions

Dimensions. Order code. Materials and finish. lindab ceiling diffusers

Swirl Diffuser. Type SDW T 2.2/1/B/1. recommended for room heights from approx m

Krantz. RL-C2 radial slot outlet. Air distribution systems

Plain diffuser. Dimensions

Air distribution systems. Radial outlet RA-N2...

CDD/CDR. Circular ceiling diffuser for supply air QUICK FACTS

Air distribution systems. Adjustable induction outlet IN-V...

Krantz. Variable twist outlet with guide ring DD-VL... jet straightener DD-VG... Air distribution systems

SWIFT Ceiling. Square ceiling air diffuser for supply air QUICK FACTS

Air distribution systems. Linear whirl outlet WL...

Air distribution systems. Jet nozzle DW-N2... Swivel jet nozzle DW-V2... Twist nozzle DW-V2-...-DR

Nozzle diffuser. Dimensions

Slot diffuser. Type VSD35 2/2.6/B/3. with 35 mm wide slot

SWIFTTM. Ceiling. Square ceiling air diffuser for supply air

Plain diffuser. Dimensions

Linear diffuser. Description

Swirl Diffusers Type DLA 7 and DLA 8

Air distribution systems. Adjustable radial outlet RA-V...

3/S3 STAIRCASE SWIRL DIFFUSERS IR, SDV, DSK. v 2.6 (en)

ALC. ALBATROSS Supply air terminal for large airflows

Linear ceiling diffuser

CDD/CDR. Single cone ceiling diffusers for supply air. Quick facts. Quick guide CDD/CDR A I R F L O W - S O U N D L E V E L

Krantz Components. Variable twist outlet with guide ring DD-VL... jet straightener DD-VG... Air distribution systems

Step Impulse Diffuser Model SIA

PELICAN Ceiling. Square ceiling air diffuser for supply air and extract air

KSV. Slot diffusers. Ordering code. Description. Linear diffusers 1 / 16

Multi-cone diffuser. Dimensions

HELLA. Linear slot diffuser. Ordering codes. HELLA - Linear diffuser. Linear Diffusers 1 / 18. Example of the ordering code HELLA B-0-0-AN

PELICAN Ceiling. Square ceiling air diffuser for supply air and extract air QUICK FACTS

PELICAN Ceiling HF. Square extract air diffuser QUICK FACTS

GRC. Circular egg crate grille for transfer/extract air and wall/ceiling mounting QUICK FACTS

series FLOOR

2/S12 DIFFUSER FOR HORIZONTAL OR VERTICAL DISCHARGE DHV. v 3.3 (en)

Multi-cone diffuser. Dimensions. Description FKD is an adjustable circular multi-cone diffuser, which is typically used for supply air.

WISE Damper. Active damper for Swegon s WISE System for demand-controlled ventilation QUICK FACTS

BNA Series. PLENUM FAN with Backward Wheels

STAIRCASE SWIRL DIFFUSERS

CIRCO. Sound-attenuating transfer unit QUICK FACTS

DBQ Painted four four-way square square diffuseurs M A D E L

variable flow dampers

AIR HANDLING REFERENCE CATALOGUE PRODUCT SUMMARY COMPANY PROFILE HOW TO CONTACT US.

Supply air nozzle. Dimensions. DAD-0 With flange for mounting on a wall or duct side.

NEO-V. Smoke Control Damper SMOKE CONTROL FUNCTION APPLICATION DESCRIPTION. in libraries of

Mechanical flow-rate controllers

Displacement Flow Diffusers

series 50-PR Square perforated face diffusers

SV-2, SV-1, AVS, AVSL, SI Grilles

AX6 adjustable blades swirl diffusers

Worth noting. Introduction. Key figures. lindab architect. Picture 1. Architect Circum, Luna and Prisma.

VK2 volume flow controller Overview

FIXED ROUND CEILING DIFFUSERS & GRILLES APPLICATION

Valve Supply and exhaust air

The diagram below. to the by the. outlet into. calculation. Since TRANSMISSION VIA STRUCTURE. Vibration Via Supports Duct Breakout

AXO adjustable vanes swirl diffusers

DCG adjustable core circular diffusers

Siv-inn School. Complete air-supply solution for school premises. Ensures excellent air supply Cleanable Reinforced front Ideal for renovation work

series KAT Acoustic air transfer units

Hudevad P100. Technical datasheet

Supply air beam. Contact, Overview, Index. Guideline heating and cooling. Plexus. Professor / Professor Plus. Premum / Premax / Solus.

NOP, NOT and NOX. Adaptable, flexible supply air diffusers with ultra low height for free installation. climecon.fi 07.16

2/S11. v 2.6 (en) SLOT DIFFUSER

Connections Standard. Description

Air Diffusion Designing for Comfort

Use. Worth noting. Key figures. Installation. lindab fasadium

AIR TECH SYSTEMS. Technical Brochure. LTG Air Diffusers. Linear air diffusers LDB. Installation in ceilings, walls and sills

Made in Italy HOSE REELS CATALOGUE TECHNOLOGY FOR FLUIDYNAMICS. No. E14/A1

Supply air beam. Contact, Overview, Index. Guideline heating and cooling. Plexus. Professor / Professor Plus. Premum / Premax / Solus.

PET PETI PET/PETI. Supply air diffuser for ceilings

Ascotherm eco KC281 Heating and cooling in 2-conductor system

Attenuation. Witt&Sohn AG Oct-14

CMA - B - C - D - CMR

textile duct texi-jet textile duct high induction diffusion through perforations applications advantages recommandations and limits of use 5.

The OCTANORM system components set a new standard in shop design.

Air Cooler Industry AC-LN 1-7 / ACA-LN 2-7 / ACAF-LN 2-7

Air Handling Unit. Konvent

Tangential Fans Series TW Impeller diameter 150 mm and 200 mm

SINGLE IMPELLER CENTRIFUGAL ELECTRIC PUMPS in cast iron

HVAC Clinic. Duct Design

INTRODUCING HORIZONTAL

EUROVENT 8/12 SOUND TEST METHOD FOR DUCTED FAN COIL UNITS. FCP 2008 testing procedures FCP acoustical test method pag. 1

G-FIRE FLANGE ADAPTERS

CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS CADB/T-N Series

VD1 CLC. Small Valves DIN-range with a higher k v -value

Contact, Overview, Index. Guideline heating and cooling. Plexus. Professor. Pilot. Architect. Polaris I & S. Plafond. Podium. Celo. Cabinett.

Transcription:

01 Ventilating grilles Grilles with thermostatic regulation Special grilles Ventilating valves Staircase swirl diffusers

SOT DIFFUSERS, ROUND DUCT DIFFUSERS SWIR DIFFUSERS, VARIABE SWIR DIFFUSERS CIRCUAR DIFFUSERS, SQUARE DIFFUSERS Ventilating VENTIATING grilles, GRIES, Ventilating VENTIATING valves VAVES Ventilating grilles, Ventilating valves Ventilating grilles are designed for all types of low-pressureair-conditioning-, heating- and ventilation systems with built in air flow- and throw distance control as well as regulation of discharge angle. They can be used for both, supply air and exhaust air applications. Ventilating valves are designed to extract air from sanitary rooms and other premises and can be also used in low pressure air-conditioning systems with air flow control. AIR DISPACEMENT UNITS SUPPY AIR NOZZES SOUND ATTENUATORS, SOUND ATTENUATING OUVRES EXTERNA EEMENTS AIR FOW CONTRO UNITS

Overview Aluminium and steel ventilating grilles, stainless steel grilles AR- AR- AR- AR-6, 7 AR-8, 9 AR-8DP AR-1 AR-1 AR-17 AR-18 AR-19 JR- JR- JR-7 JR-8 RR-1 RR- RR- RR-6 JRU- JRU-6 Duct grilles for circular and rectangular ducts Grilles with thermostatic regulation (aluminium, steel) SK-2 SK- SK- SK-9 AR-18/TR JR-8/TR Ceiling grilles Special grilles (Grease traps, Filter grilles, inear grilles) SR-1 SR-2 SR- SR- M-1 M-2 SR- SR-6 SR-7 SR-8 /PF /T Ventilating valves and staircase swirl diffusers PV-1N PV-2N PV- STD-1 STD-2 6

Content Ventilating grilles 8 Aluminium grilles AR-, AR-, AR-P, AR-V, AR-, AR-6, AR-7, AR-8, AR-9, AR-19, AR-8DP 8 Aluminium and steel grilles AR-1, JR-, JRP-, AR-1, JR-, JRP-, AR-17, JR-7, JRP-7, AR-18, JR-8, JRP-8 12 Stainless steel grilles RR-1, RR-, RR-, RR-6 1 Curved steel grilles JRU-, JRU-6 1 Steel duct grilles SK-2, SK-, SK-, SK-9 16 Steel ceiling grilles SR-1, SR-2, SR-, SR- 18 Aluminium ceiling grilles SR-, SR-6, SR-7, SR-8 Ventilating grilles installation 22 Registers F, S, T, PP 2 Installation of registers in the floor grilles AR-8, AR-9 26 Technical data 28 Effective discharge area A ef (m²) 28 Ventilating grilles AR-1, 1, 17, 18; JR-,, 7, 8; RR-1,,, 6; SK-2,,, 9 without ceiling effect (distance from ceiling 0.8 m) 0 Ventilating grilles AR-1, 1, 17, 18; JR-,, 7, 8 without ceiling effect (distance from ceiling 0.8 m) 1 Ventilating grilles AR-1, 1, 17, 18; JR-,, 7, 8; RR-1,,, 6; SK-2,,, 9 without ceiling effect (distance from ceiling 0.8 m) 2 Ventilating grilles AR-1, 1, 17, 18; JR-,, 7, 8; RR-1,,, 6 with ceiling effect (distance from ceiling 0. m) Ventilating grilles AR-1, 1, 17, 18; JR-,, 7, 8; RR-1,,, 6 with ceiling effect (distance from ceiling 0. m) Page Technical data for ventilating grilles 6 Technical data for extracting grilles 7 Aluminium grilles AR-6, AR-7 with ceiling effect (distance from ceiling 0. m) 9 Aluminium grilles AR-6, AR-7, AR-8, AR-9 without ceiling effect (distance from ceiling 0. m) 0 Aluminium and steel ceiling grilles SR-1, SR-2, SR-, SR-, SR-, SR-6, SR-7, SR-8 1 Grilles with thermostatic regulation Aluminium grille with thermostatic regulation AR-18/TR Steel grille with thermostatic regulation JR-8/TR Special grilles Grease traps M-1, M-2 Filter grilles /PF 7 inear grilles /T 8 Blade inserts 9 Plenum box for grilles 0 Plenum boxes 0 Ventilating valve 2 Ventilating valve PV-1N 2 Ventilating valve PV-2N Ventilating valve PV- 6 Staircase swirl diffuser 8 Staircase swirl diffusers STD-1 8 Staircase swirl diffusers STD-2 61 Page Ventilating VENTIATING grilles, GRIES, Ventilating VENTIATING valves VAVES CIRCUAR DIFFUSERS, SQUARE DIFFUSERS SWIR DIFFUSERS, VARIABE SWIR DIFFUSERS SOT DIFFUSERS, ROUND DUCT DIFFUSERS AIR DISPACEMENT UNITS SUPPY AIR NOZZES egend of symbols AI Element is made of aluminium profiles, aluminium sheet or aluminium casting. Element is intended to be built in the wall. Element is suitable for the supply of cool air (cooling). EXTERNA EEMENTS St RA 90 Element is made of steel sheet. Element is powder painted in standard RA 90 colour. Other desired colour is to be specified in the order. Element is intended to be built in the ceiling or in the wall. Element for air conditioning of rooms with floor to ceiling heights room up to m. M F EU... Element allows regulation by electric motor (Belimo electric motors). Element is intended for air filtration. The filter of class is built in. AIR FOW CONTRO UNITS Shady symbol means possibility of optional material, surface protection, motor version, Element is intended to be built in the floor. Element for air conditioning of rooms with floor to ceiling heights from 6 to 1 m. Element is suitable for the supply of warm air (heating). CD INOX The possibility of the automatic selection and calculation of the technical characteristics of grilles and difusers in regard to the given conditions with the assistance of the Klima ADE program. The element is made of stainless sheet steel AISI 0. SOUND ATTENUATORS, SOUND ATTENUATING OUVRES 7

Ventilating grilles Ventilating grilles Aluminium grilles AR- Fixed horizontal blades Visible screw installation Preferably for return air AI RA 90 AR- Fixed horizontal blades Visible screw installation or bars Possible installation of AR-P counterframe Suitable for pressure equalising between the rooms To some extent blocks the light and sound Standard grille dimensions H min=12 AI RA 90 AR-P Wall or ceiling installation of AR-P with counterframe B1 = B-28 H1 = H-19 B = B-2 H = H-1 2 H1/B1 28 min 2 7 AR-V Installation of AR-V with bars in door or wall B1 = B-2 H1 = H-16 26. H1/B1 7 8

Ventilating grilles AR- Special screen made of PVC Frame is made of aluminium Visible or hidden screw installation AI 12. Ventilating VENTIATING grilles, GRIES, Ventilating VENTIATING valves VAVES RA 90 CIRCUAR DIFFUSERS, SQUARE DIFFUSERS AR-6, AR-7 For wall installation Fixed horizontal blades Type AR-6: 0 fixed blades Type AR-7: 1 fixed blades Visible or hidden screw installation AI RA 90 AR-6 12. AR-7 12. SWIR DIFFUSERS, VARIABE SWIR DIFFUSERS AR-8, AR-9 For floor installation Fixed horizontal blades Type AR-8: 0 fixed blades Type AR-9: 1 fixed blades Grille insert can be removed for cleaning purpose. CD AI 2 2 12. 12. SOT DIFFUSERS, ROUND DUCT DIFFUSERS AIR DISPACEMENT UNITS SUPPY AIR NOZZES Standard dimensions: B/H 7 12 22 2 2 2 22 2 2 2 62 82 2 122 Aluminium grilles can be anodised in the following colours: Standard: Natural aluminium colour (C0) Upon customer s request: golden (C) - black (C) - brass colour (C) EXTERNA EEMENTS SOUND ATTENUATORS, SOUND ATTENUATING OUVRES AIR FOW CONTRO UNITS 9

Ventilating grilles AR-19 For air exhaust Frame and screen made of anodized aluminium Visible or hidden screw installation AI RA 90 1 Standard dimensions: B/H 0 10 0 20 00 0 00 0 00 0 600 0 20 00 0 00 0 00 0 600 60 700 70 800 80 900 90 00 Ordering key AR-/2-F B x H F Registers (see page 27) 2 Non-visible installation with subframe and screw lock V Visible screw installation Grille type AR-, AR-6, AR-7, AR-19 (installation 2 and V). AR-, AR-, AR-P (V installation only). AR-8, AR-9 (floor installation)

H VENTIATING GRIES, Ventilating grilles, Ventilating VAVES VENTIATING valves Ventilating grilles, Ventilating valves Ventilating grilles 12. H AR-8-DP For floor installation Fixed horizontal blades Blades12. under 90 angle B 00 2 600 SWIR DIFFUSERS, VARIABE SWIR DIFFUSERS 2 00 h B/H h Standard dimensions Other dimensions on customer s request possible. 2 2 Aluminium grilles can be anodised in the following colours: Standard: Natural aluminium colour (C0) Upon customer s request: - golden (C) - black 12. (C) - brass colour (C) CIRCUAR DIFFUSERS, SQUARE DIFFUSERS AI H h h 22 22 AR-8-DP SOT DIFFUSERS, ROUND DUCT DIFFUSERS 600 h 2 AIR DISPACEMENT UNITS 2 AR-8-DP/F EXTERNA EEMENTS 2 h 2 Ordering key AIR FOW CONTRO UNITS 2 h 2 h 2 Installation SUPPY AIR NOZZES 2 12. AR-8-DP/F B x H x C CO Eloxal treated SOUND ATTENUATORS, SOUND ATTENUATING OUVRES Grille to floor height: standard h = 6, 1 and mm (on customer s request also) Register F (aluminium blade) For installation into double floor 11

Ventilating grilles Aluminium and steel grilles Visible or hidden screw installation Steel sheet powder painted in standard RA 90 colour or aluminium anodised extruded profiles AR-1, JR-, JRP- Individually adjustable horizontal blades AR-1: aluminium anodised extruded profiles JRP-: galvanised steel sheet AI RA 90 CD St AR-1, JR-, JRP- Individually adjustable vertical blades AR-1: aluminium anodised extruded profiles JRP-: galvanised steel sheet AI RA 90 CD St AR-17, JR-7, JRP-7 6 Individually adjustable horizontal and vertical blades AR-17: aluminium anodised extruded profiles JRP-7: galvanised steel sheet AI RA 90 CD St AR-18, JR-8, JRP-8 6 Individually adjustable horizontal and vertical blades AR-18: aluminium anodised extruded profiles JRP-8: galvanised steel sheet AI RA 90 CD St Ordering key AR-1/2-F B x H F Registers F, S, T V Visible screw installation 2 Hidden screw installation V2 Visible screw installation + installation frame Spring 1 Grille type AR-1, AR-1, AR-17, AR-18, JR-, JR-, JR-7, JR-8 AR Aluminium grille JR Steel grille JRP Galvanised steel grille 12

Ventilating grilles Stainless steel grilles RR-1, RR-, RR-, RR-6 Visible or hidden screw installation Flat framer Stainless steel AISI 0 (BA polished, high gloss) RR-1 Individually adjustable vertical and horizontal blades RR- Fixed horizontal blades RR- Individually adjustable horizontal blades RR-6 Individually adjustable vertical blades INOX 6 Ventilating VENTIATING grilles, GRIES, Ventilating VENTIATING valves VAVES CIRCUAR DIFFUSERS, SQUARE DIFFUSERS SWIR DIFFUSERS, VARIABE SWIR DIFFUSERS SOT DIFFUSERS, ROUND DUCT DIFFUSERS AIR DISPACEMENT UNITS SUPPY AIR NOZZES EXTERNA EEMENTS Ordering key RR-1/V F F Register classic FI Register INOX (frame INOX, aluminium blades) C Register INOX (for RR- only) C1 Register INOX (for RR-6 only) V Visible screw installation screw INOX 2 Installation frame and locks galvanised (for RR-1,, 6 only) 2I Installation frame INOX and galvanised locks (for RR-1,, 6 only) V2 Visible screw installation + installation frame galvanised V2I Visible screw installation + installation frame INOX grille type RR-1, RR-, RR-, RR-6 AIR FOW CONTRO UNITS SOUND ATTENUATORS, SOUND ATTENUATING OUVRES 1

Ventilating grilles Grille standard dimensions and cross-sections (m²) for AR-1, AR-1, JR-, JR-, RR-, RR-6: B/H 7 12 17 22 2 2 2 22 0.007 0.01 0.021 0.029 2 0.011 0.02 0.0 0.0 0.066 2 0.01 0.01 0.0 0.060 0.089 0.118 2 0.019 0.08 0.0 0.07 0.112 0.18 0.18 62 0.022 0.06 0.067 0.090 0.1 0.179 0.22 72 0.026 0.0 0.078 0.6 0.17 0.9 0.261 82 0.00 0.062 0.089 0.121 0.180 0.29 0.298 92 0.0 0.070 0.1 0.16 0. 0.270 0.6 2 0.08 0.077 0.112 0.11 0.226 0.00 0.7 112 0.01 0.08 0.12 0.167 0.28 0.0 0.12 122 0.0 0.09 0.1 0.182 0.271 0.60 0.0 B/H 0 10 0 20 00 0 00 00 10 0.007 0.011 0 0.0 0.016 0.022 20 0.01 0.021 0.029 0.07 00 0.01 0.026 0.0 0.06 0.0 0 0.018 0.01 0.02 0.0 0.06 0.078 00 0.021 0.06 0.09 0.06 0.076 0.090 0. 0 0.02 0.01 0.0 0.072 0.086 0. 0.117 00 0.027 0.06 0.062 0.080 0.097 0.11 0.11 0.166 600 0.0 0.0 0.07 0.098 0.117 0.10 0.160 0.2 700 0.09 0.06 0.088 0.11 0.18 0.16 0.188 0.28 800 0.0 0.07 0.2 0.12 0.19 0.190 0.216 0.27 900 0.00 0.08 0.11 0.10 0.180 0.21 0.2 0.09 00 0.06 0.09 0.128 0.167 0.1 0.29 0.27 0. 10 0.062 0. 0.12 0.18 0.221 0.26 0.01 0.81 10 0.068 0.11 0.1 0.2 0.22 0.289 0.0 0.17 Grille standard dimensions and cross-sections (m²) for AR-17, AR-18, JR-7, JR-8, RR-1: B/H 7 12 17 22 2 2 2 22 0.006 0.01 0.021 0.029 2 0.009 0.0 0.02 0.0 0.066 2 0.012 0.027 0.02 0.07 0.088 0.118 2 0.01 0.0 0.0 0.072 0.9 0.17 0.18 62 0.018 0.00 0.06 0.086 0.11 0.176 0.222 72 0.021 0.07 0.07 0.0 0.1 0.6 0.28 82 0.02 0.0 0.08 0.11 0.17 0.2 0.29 92 0.027 0.061 0.09 0.128 0.196 0.26 0.2 2 0.00 0.067 0. 0.12 0.218 0.29 0.68 112 0.02 0.07 0.11 0.17 0.29 0.22 0.0 122 0.0 0.081 0.126 0.171 0.261 0.1 0.2 B/H 0 10 0 20 00 0 00 00 10 0.006 0.011 0 0.009 0.01 0.022 20 0.011 0.0 0.029 0.07 00 0.01 0.02 0.0 0.0 0.0 0 0.016 0.028 0.01 0.0 0.066 0.078 00 0.018 0.02 0.07 0.061 0.07 0.089 0. 0 0.021 0.07 0.0 0.069 0.08 0.2 0.118 00 0.02 0.01 0.09 0.077 0.09 0.11 0.10 0.166 600 0.028 0.09 0.071 0.09 0.11 0.16 0.18 0.1 700 0.0 0.08 0.08 0.9 0.1 0.160 0.18 0.26 800 0.07 0.067 0.096 0.12 0.1 0.18 0.212 0.271 900 0.02 0.07 0.8 0.11 0.17 0.7 0.20 0.0 00 0.07 0.08 0.1 0.17 0.19 0.20 0.267 0.0 10 0.02 0.092 0.1 0.17 0.21 0.2 0.29 0.7 10 0.07 0.1 0.1 0.189 0.2 0.277 0.22 0. Standard dimensions for RR-: B/H 7 12 22 2 2 2 22 2 2 2 62 82 2 122 1

Ventilating grilles Curved steel grilles Application Ventilating curved grilles are designed for all types of low-pressure- air-conditioning, heating and ventilation systems with built in air flow and throw distance control. JRU- 6 also has built-in regulation of discharge angle. They can be used for both, supply air and exhaust air applications. Description Steel curved grilles are made of sheet steel and powder-coated in RA 90. Upon customers request they can be made of galvanised or stainless steel or painted in any other RA colour. Both types are available in concave or convex version. Standard dimensions St RA 90 28 B R Ventilating VENTIATING grilles, GRIES, Ventilating VENTIATING valves VAVES CIRCUAR DIFFUSERS, SQUARE DIFFUSERS SWIR DIFFUSERS, VARIABE SWIR DIFFUSERS B/H 7 12 22 2 2 2 22 2 2 2 62 SOT DIFFUSERS, ROUND DUCT DIFFUSERS 82 2 112 122 28 R AIR DISPACEMENT UNITS JRU- Individually adjustable horizontal curved blades Frame (curve R) Visible screw installation JRU B H R min (mm) 9 0 0 B SUPPY AIR NOZZES JRU-6 Individually adjustable vertical curved blades Frame (curve R) Visible screw installation EXTERNA EEMENTS JRU 6 B H R min (mm) 9 0 0 Ordering key AIR FOW CONTRO UNITS JRU /V/KK B x H x R KK Convex KO Concave Visible screw installation Grille type SOUND ATTENUATORS, SOUND ATTENUATING OUVRES 1

Ventilating grilles Steel duct grilles SK-2, SK-, SK-, SK-9 For circular ducts Visible screw installation ASK-2, ASK-, ASK-: aluminium type SKP-2, SKP-, SKP-, SKP-9: galvanised steel type St RA 90 AI CD SK-2 Individually adjustable horizontal and vertical blades H-1/B-1 H1/B1 H-1/B-1 H1/B1 H-1/B-1 H1/B1 H-1/B-1 H1/B1 SK- Individually adjustable vertical blades SK- Individually adjustable horizontal blades SK-9 Individually adjustable horizontal and vertical blades 16

Ventilating grilles Standard dimensions B/H 7 12 22 2 22 2 2 2 62 82 2 122 a H H1/B1 H-1/B-1 D B1 = B-27 H1 = H-27 Ventilating VENTIATING grilles, GRIES, Ventilating VENTIATING valves VAVES CIRCUAR DIFFUSERS, SQUARE DIFFUSERS Dimensions H H a diameter D 7 9 7 0-00 12 67 1 00-900 SWIR DIFFUSERS, VARIABE SWIR DIFFUSERS 22 82 600-200 2 12 7 900-200 Ordering key SK-2 / V-F B x H F Registers (see page 27) V Visible screw installation Grille type SOT DIFFUSERS, ROUND DUCT DIFFUSERS AIR DISPACEMENT UNITS ASK Aluminium grilles SK Steel grilles SKP Galvanised steel grilles SOUND ATTENUATORS, SOUND ATTENUATING OUVRES AIR FOW CONTRO UNITS SUPPY AIR NOZZES EXTERNA EEMENTS 17

Ventilating grilles Steel ceiling grilles SR-1, SR-2, SR-, SR- Fixed blades Visible screw installation Foamy sealing strip around the frame Ceiling installation ASR -1, 2,, aluminium types made of Al sections St RA 90 AI H-16/B-16 27 SR-1 One-way air supply 1 H1 B1 SR-2 Two-way air supply 2 H1 2 B1 SR- Three-way air supply H1 B1 SR- Four-way air supply H1 B1 18

Ventilating grilles Standard dimensions B/H 8 26 76 2 62 62 87 71 71 71 671 871 71 1271 62 87 962 1162 1212 Ventilating VENTIATING grilles, GRIES, Ventilating VENTIATING valves VAVES CIRCUAR DIFFUSERS, SQUARE DIFFUSERS SWIR DIFFUSERS, VARIABE SWIR DIFFUSERS Ordering key SR-1/V-F2 B x H F2 Registers (see page 27) V Visible screw installation V2 Visible screw installation+installation frame Grille type SR Steel grilles ASR Aluminium grilles SRP Galvanised steel grilles SOT DIFFUSERS, ROUND DUCT DIFFUSERS SOUND ATTENUATORS, SOUND ATTENUATING OUVRES AIR FOW CONTRO UNITS AIR DISPACEMENT UNITS EXTERNA EEMENTS SUPPY AIR NOZZES 19

Ventilating grilles Aluminium ceiling grilles SR-, SR-6, SR-7, SR-8 Individually adjustable blades Visible or hidden installation Ceiling installation AI RA 90 2 SR- One-way air supply 1 H1 B1 SR-6 Two-way air supply 2 H1 2 B1 SR-7 Three-way air supply H1 B1 SR-8 Four-way air supply H1 B1

Ventilating grilles Standard dimensions B/H 12 22 2 2 2 22 2 2 2 62 82 2 122 Ordering key SR-/V-F B x H Ventilating VENTIATING grilles, GRIES, Ventilating VENTIATING valves VAVES CIRCUAR DIFFUSERS, SQUARE DIFFUSERS SWIR DIFFUSERS, VARIABE SWIR DIFFUSERS F Registers (see page 27) V Visible screw installation 2 Non-visible screw installation V2 Visible screw installation + installation frame Grille type SOUND ATTENUATORS, SOUND ATTENUATING OUVRES AIR FOW CONTRO UNITS EXTERNA EEMENTS SOT DIFFUSERS, ROUND DUCT DIFFUSERS SUPPY AIR NOZZES AIR DISPACEMENT UNITS 21

Ventilating grilles Ventilating grilles installation Wall installation with built-in frame and hidden fixing (lock) B1 = B-28 H1 = H-28 B2 = B-1 H2 = H-1 H1/B1 27(28)* 7 The list of grilles and their designation: RR-1/2, RR-/2, RR-/2 and RR-6/2 * Dimension (28) is valid for following grilles: AR-/2, AR-6/2, AR-7/2, AR-19/2, SR-(-8)/2 H2/B2 Wall installation with built-in frame and visible fixing B1 = B-28 H1 = H-28 (for AR- je H1 = H-19) B2 = B-1 H2 = H-1 The list of grilles and their designation: RR-1/V2, RR-/V2, RR-/V2, RR-6/V2, SR-(1-)/V2 * Dimension (28) is valid for following grilles: AR-/V2, AR-/V2, AR-/V2, AR-6/V2, AR-7/V2, SR-(-8)/V2 H1/B1 27(28)* 7 H2/B2 Installation on wall or duct with screw-type installation frame and hidden fixing (lock) B1 = B-28 H1 = H-28 B2 = B-1 H2 = H-1 H1/B1 27(28)* 7 The list of grilles and their designation: RR-1/2, RR-/2, RR-/2 in RR-6/2 * Dimension (28) is valid for following grilles: AR-/2, AR-6/2, AR-7/2, AR-19/2, SR-(-8)/2 H2/B2 Installation on wall or duct with screw-type installation frame and visible fixing B1 = B-28 H1 = H-28 (for AR- je H1 = H-19) B2 = B-1 H2 = H-1 The list of grilles and their designation: RR-1/V2, RR-/V2, RR-/V2, RR-6/V2, SR-(1-)/V2 * Dimension (28) is valid for following grilles: AR-/V2, AR-/V2, AR-/V2, AR-6/V2, AR-7/V2, SR-(-8)/V2 H1/B1 27(28)* H2/B2 7 22

Ventilating grilles Direct installation in wall or duct via the visible fixing B1 = B-28 H1 = H-28 The list of grilles and their designation: RR-1/V, RR-/V, RR-/V, RR-6/V, SR-(-8)/V * Dimension (28) is valid for following grilles: AR-/V, AR-/V, AR-6/V, AR-7/V, AR-19/V Installation of floor grilles with built-in supporting frame B1 = B-18 H1 = H-18 B = B+ H = H+ The list of grilles and their designation: AR-8, AR-9 2 H1/B1 H-/B- 27(28)* 7 H1/B1 Ventilating VENTIATING grilles, GRIES, Ventilating VENTIATING valves VAVES CIRCUAR DIFFUSERS, SQUARE DIFFUSERS SWIR DIFFUSERS, VARIABE SWIR DIFFUSERS Installation of SK-2,,,9 grilles directly in the round duct with visible screw-fixing The list of grilles and their designation: SK-2, SK-, SK-, SK-9 B-1 H-1 H-1/B-1 H1/B1 R SOT DIFFUSERS, ROUND DUCT DIFFUSERS AIR DISPACEMENT UNITS Mounting of grilles without installation frame Visible screw installation / V B1 = B-27 H1 = H-27 AR-1, AR-1, JR-, JR- h = mm AR-17, AR-18, JR-7, JR-8 h = 6 mm Marking: AR-1/V, AR-1/V, AR-17/V, AR-18/V, JR-/V, JR-/V, JR-7/V, JR-8/V Mounting of grilles with installation frame h H1/B1 28 H-/B- SUPPY AIR NOZZES EXTERNA EEMENTS The installation frame may be mortar-mounted (in concrete or brick walls) or fixed with screws (walls, ceilings, ducts, ). SOUND ATTENUATORS, SOUND ATTENUATING OUVRES AIR FOW CONTRO UNITS 2

Ventilating grilles Hidden screw fixing / 2 (lock) B1 = B-27 H1 = H-27 AR-1, AR-1, JR-, JR- h = mm AR-17, AR-18, JR-7, JR-8 h = 6 mm Marking: AR-1/2, AR-1/2, AR-17/2, AR-18/2, JR-/2, JR-/2, JR-7/2, JR-8/2 h H1/B1 28 Visible screw fixing + installation frame / V2 B1 = B-27 H1 = H-27 H1/B1 28 AR-1, AR-1, JR-, JR- h = mm AR-17, AR-18, JR-7, JR-8 h = 6 mm h Marking: AR-1/V2, AR-1/V2, AR-17/V2, AR-18/V2, JR-/V2, JR-/ V2, JR-7/V2, JR-8/V2 Hidden fixing / (spring) Warning: only for wall installation B1 = B-27 H1 = H-27 AR-1, AR-1, JR-, JR- h = mm AR-17, AR-18, JR-7, JR-8 h = 6 mm Marking: AR-1/, AR-1/, AR-17/, AR-18/, JR-/, JR-/, JR-7/, JR-8/ h H1/B1 28 28 H1/B1 2

Ventilating grilles Registers When adjusting the system, desired operating conditions are obtained by the means of ventilation elements control. Registers are installed for additional air volume control, thus influencing air velocity and throw distance as well. All types of registers, except type of register F, are made of sheet steel and corrosion protected with dipcoat processing in blackwater soluble colour. Upon customer s request registers can be made of galvanised sheet steel and coloured in any colour. Typ of register F is made of plastics. Ventilating VENTIATING grilles, GRIES, Ventilating VENTIATING valves VAVES CIRCUAR DIFFUSERS, SQUARE DIFFUSERS F Register has wide counter-directional blades which can be moved with screw-driver via the gear wheel. It is used to control the air flow volume.blades are made of plastics. S Register has fixed deflector and slider which opens and closes the slots. Due to inclined deflection, air volume damper S is particularly useful for longer grilles, because air flow is evenly distributed throughout the grille. T Register has fixed deflector and slider which opens and closes the slots. It isused to control and deflect the air flow from the duct. PP Perforated sheet steel ( %) is used to split the air jet. Unfavourable is increased noise. 0 70 max 0 87 67 SWIR DIFFUSERS, VARIABE SWIR DIFFUSERS SOT DIFFUSERS, ROUND DUCT DIFFUSERS SOUND ATTENUATORS, SOUND ATTENUATING OUVRES AIR DISPACEMENT UNITS SUPPY AIR NOZZES EXTERNA EEMENTS AIR FOW CONTRO UNITS 2

Ventilating grilles Installation of registers in the floor grilles AR-8, AR-9 F Register has wide counter-directional blades which can be moved with screw-driver via the gear wheel. It is used to control the air flow volume. Blades are made of black plastics. B-2 / H-2 Set-up of different registers Register F Register T 26

Ventilating grilles Ventilating grilles/registers combinations Perforated sheet steel Grille F F2 S T PP AR- o AR- AR- o o o AR-6 o o o AR-7 o o o AR-8 o o o AR-8DP AR-9 o o o AR-1 AR-1 AR-17 AR-18 AR-19 JR- JR- JR-7 JR-8 RR-1 o o RR- o RR- o o RR-6 o o SK-2 o o SK- o o SK- o o SK-9 o o ASK-2 o o ASK- o o ASK- o o SR-1 SR-2 SR- SR- ASR-1 ASR-2 ASR- ASR- SR- o o o SR-6 o o o SR-7 o o SR-8 o o standard combiantion o possible combination Ventilating VENTIATING grilles, GRIES, Ventilating VENTIATING valves VAVES CIRCUAR DIFFUSERS, SQUARE DIFFUSERS SWIR DIFFUSERS, VARIABE SWIR DIFFUSERS SOT DIFFUSERS, ROUND DUCT DIFFUSERS AIR DISPACEMENT UNITS SUPPY AIR NOZZES EXTERNA EEMENTS AIR FOW CONTRO UNITS SOUND ATTENUATORS, SOUND ATTENUATING OUVRES 27

Technical data Technical data Effective discharge area A ef (m²) B H AR- RR- AR- AR- AR-6, 7 AR-8, 9 22 7 0.0060 0.0080 0.0060 0.0080 0.0090 0.0080 2 0.00 0.01 0.0080 0.01 0.010 0.01 2 0.010 0.0160 0.01 0.010 0.0170 0.010 2 0.0160 0.00 0.010 0.0190 0.02 0.0180 62 0.0190 0.020 0.0170 0.020 0.020 0.02 82 0.0260 0.00 0.020 0.000 0.00 0.000 2 0.0 0.0 0.0280 0.080 0.0 0.060 122 0.080 0.090 0.00 0.060 0.0 0.00 22 12 0.0090 0.0070 0.010 0.01 0.010 0.0170 0.010 2 0.010 0.01 0.02 0.0170 0.020 0.0260 0.020 2 0.0190 0.010 0.0280 0.02 0.0 0.00 0.0 2 0.020 0.0180 0.00 0.0280 0.090 0.00 0.070 62 0.0290 0.02 0.00 0.00 0.070 0.0 0.00 82 0.080 0.0290 0.070 0.00 0.06 0.0690 0.06 2 0.080 0.060 0.07 0.060 0.0780 0.0860 0.070 122 0.070 0.00 0.0860 0.0680 0.090 0.0 0.0900 2 22 0.0 0.020 0.00 0.00 0.060 0.00 0.070 2 0.00 0.0 0.080 0.00 0.06 0.07 0.060 2 0.00 0.000 0.070 0.060 0.0760 0.0870 0.070 62 0.060 0.080 0.0870 0.0670 0.09 0.0 0.09 82 0.0860 0.060 0.1170 0.0890 0.12 0.100 0.12 2 0.70 0.08 0.160 0.11 0.10 0.170 0.100 122 0.1290 0.0970 0.1760 0.10 0.180 0.90 0.18 2 2 0.0660 0.000 0.0880 0.0670 0.09 0.70 0.090 2 0.080 0.06 0.10 0.080 0.110 0.1 0.110 62 0.00 0.070 0.1 0.00 0.160 0.170 0.160 82 0.10 0.00 0.1770 0.10 0.18 0.21 0.180 2 0.1670 0.120 0.22 0.1680 0.2280 0.26 0.2260 122 0. 0.1 0.2660 0. 0.270 0.10 0.270 62 2 0.160 0. 0.1770 0.10 0.18 0. 0.18 82 0.18 0.160 0.270 0.1780 0.2 0.28 0.260 2 0.2270 0.1700 0.2960 0.220 0.0 0.90 0.0 122 0.27 0.0 0.60 0.2680 0.60 0.2 0.60 2 2 0.2870 0.210 0.7 0.20 0.770 0.70 0.770 122 0.0 0.280 0.60 0.880 0.0 0.270 0.70 RR- SK- ASK- RR-1 SK- RR-6 ASK- SK-2 ASK-2 SK-9 Discharge or inlet air flow volume is determined via air velocity measuring at the effective area with horizontally positioned blades. Use the below formula to calculate air flow volume Q = V ef x A ef x 600 (m³/h) V ef (m/s) A ef (m²) Effective jet velocity Effective area 28

Technical data Ventilating VENTIATING grilles, GRIES, Ventilating VENTIATING valves VAVES F F F F F B H SR-1 SR-2 SR- SR-, SR- 71 8 0.00 0.0080 0.0080 0.00 0.000 71 0.0260 0.00 0.00 0.00 0.0090 71 0.00 0.010 0.010 0.00 0.012 671 0.090 0.0160 0.010 0.00 0.010 871 0.0 0.02 0.00 0.00 0.00 71 0.060 0.0260 0.020 0.00 0.020 1271 0.0780 0.0 0.000 0.00 0.000 71 26 0.060 0.010 0.010 0.006 0.01 71 0.00 0.00 0.0180 0.006 0.010 671 0.00 0.020 0.02 0.006 0.0180 871 0.070 0.0 0.0290 0.006 0.0260 71 0.09 0.090 0.070 0.006 0.00 1271 0.90 0.070 0.00 0.006 0.0 71 0.080 0.0260 0.02 0.007 0.0180 671 0.0700 0.0 0.0270 0.007 0.020 871 0.090 0.0 0.080 0.007 0.00 71 0.1170 0.0 0.080 0.007 0.00 1271 0.100 0.06 0.080 0.007 0.00 671 76 0.0860 0.090 0.00 0.01 0.0280 871 0.110 0.0 0.060 0.01 0.0 71 0.10 0.060 0.0600 0.01 0.00 1271 0.17 0.0780 0.07 0.01 0.0670 871 2 0.10 0.06 0.00 0.017 0.060 71 0.1690 0.0780 0.0700 0.017 0.06 1271 0.0 0.090 0.0860 0.017 0.0780 62 62 0.07 0.060 0.0270 0.0182 0.0180 962 0.16 0.08 0.07 0.0182 0.060 62 62 0.110 0.070 0.0 0.029 0.0290 1162 0.20 0.1280 0.110 0.029 0.0990 87 87 0.1270 0.0600 0.00 0.0 0.0 1212 0.28 0.10 0.1170 0.0 0. F F F F F B H SR- SR-6 SR-7,8 SR-7 SR-8 22 12 0.000 0.002 0.001 0.001 0.0007 2 0.0070 0.00 0.0022 0.0022 0.0011 2 0.00 0.000 0.00 0.00 0.0016 2 0.01 0.0060 0.000 0.000 0.00 62 0.010 0.0070 0.006 0.006 0.002 82 0.0190 0.009 0.0062 0.0062 0.001 2 0.020 0.01 0.0080 0.0080 0.000 122 0.0290 0.01 0.009 0.009 0.006 2 22 0.0170 0.0070 0.000 0.000 0.00 2 0.02 0.00 0.0060 0.0070 0.000 2 0.0280 0.01 0.0080 0.00 0.000 62 0.00 0.010 0.01 0.00 0.000 82 0.00 0.0190 0.010 0.0160 0.0070 2 0.060 0.020 0.0190 0.0190 0.0080 122 0.0670 0.0290 0.020 0.02 0.0090 2 2 0.00 0.0160 0.00 0.01 0.000 2 0.00 0.00 0.01 0.0160 0.0070 62 0.00 0.020 0.0170 0.0160 0.0070 82 0.0700 0.0 0.02 0.020 0.01 2 0.0880 0.000 0.0290 0.0290 0.010 122 0.0 0.080 0.060 0.00 0.010 62 2 0.07 0.00 0.02 0.02 0.00 82 0.0960 0.00 0.0290 0.00 0.0160 2 0.10 0.060 0.080 0.000 0.0190 122 0.100 0.0670 0.080 0.060 0.02 2 2 0.100 0.07 0.080 0.0 0.020 122 0.18 0.0860 0.0600 0.080 0.0280 CIRCUAR DIFFUSERS, SQUARE DIFFUSERS SWIR DIFFUSERS, VARIABE SWIR DIFFUSERS SOT DIFFUSERS, ROUND DUCT DIFFUSERS AIR DISPACEMENT UNITS SUPPY AIR NOZZES EXTERNA EEMENTS Calculation of A ef SR-1 A ef = SR-2 A ef = 2 x SR- A ef =2x + SR- A ef =2x +2x SR- A ef = SR-6 A ef = 2 x SR-7 A ef =2x + SR-8 A ef =2x +2x AIR FOW CONTRO UNITS SOUND ATTENUATORS, SOUND ATTENUATING OUVRES 29

Technical data Ventilating grilles AR-1, 1, 17, 18; JR-,, 7, 8; RR-1,,, 6; SK-2,,, 9 without ceiling effect (distance from ceiling 0.8 m) Chart for determining the size, induction and temperature of the air flow valid for B/H 12 fully opened blades 122 2 122 Effective discharge air velocity v ef (m/s) 2 1. 1 2 122 82 2 62 82 122 62 2 7 8 6 Induction i 1 2 82 000 2 62 122 2 2 2 82 000 00 0. 0 0 2 62 122 2 2 100 0. 2 2 82 62 00 800 0.2 22 2 2 2 600 00 00 0.1 Width B (mm) 2 2 2 22 Height H (mm) 12 22 7 00 0 10 Air flow Q (m /h) 0.0 0.0 0.0 Temperature factor t t z Air jet velocity v (m/s) 6 7 8 9 1 1.0 0.7 0. 0. 0. 0.2 1 Throw distance (m) 1. Air jet width b 0.2(m) 1.0 0.9 8 7 6 Definition of Symbols Q 0.2 b v (m/s) t ( C) v = 0.2 m/s 0.8m Q (m /h) t ( C) Z Q (m³/h) (m) V ef (m/s) V (m/s) Air flow Throw distance Effective discharge air velocity Max. air velocity at the throw distance 0.2 A Q Occupied zone Δt z (K) Δt (K) i b 0.2 (m) Temperature difference between supply and room air Temperature difference between air jet and room temperature Induction rate = total airstream volume flow / volume flow at diffuser discharge Width of air jet is measured at a distance from ceiling where air flow velocity 0.2 m/s 0

Technical data Ventilating grilles AR-1, 1, 17, 18; JR-,, 7, 8 without ceiling effect (distance from ceiling 0.8 m) Chart for determining the size, induction and temperature of the air flow valid for B/H 12 fully opened blades 10 10 00 10 900 10 10 800 00 10 10 700 900 00 10 600 800 900 00 10 700 800 900 10 00 600 700 800 00 10 900 00 600 700 800 10 0 00 600 00 00 00 700 900 10 0 800 10 00 600 700 00 0 0 00 900 00 0 600 800 10 0 00 00 700 10 00 0 00 0 00 0 20 00 0 20 00 600 00 900 00 800 0 00 700 0 20 0 600 00 0 00 0 00 000 7 8 000 6 00 100 00 800 600 Effective discharge air velocity v ef (m/s) 2 1. 1 0. 0. 0.2 Induction i 1 0 0 Ventilating VENTIATING grilles, GRIES, Ventilating VENTIATING valves VAVES CIRCUAR DIFFUSERS, SQUARE DIFFUSERS SWIR DIFFUSERS, VARIABE SWIR DIFFUSERS SOT DIFFUSERS, ROUND DUCT DIFFUSERS Width B (mm) 00 00 0 00 20 0 Height H (mm) 10 20 0 10 10 0 00 00 00 0 10 Air flow Q (m /h) 0.1 0.0 0.0 0.0 Temperature factor t t z AIR DISPACEMENT UNITS 1.0 0.7 0. 0. 0. 0.2 1. 1.0 0.9 Air jet width b 0.2(m) Air jet velocity v (m/s) 1 8 7 6 Throw distance (m) 6 7 8 9 1 Throw distance (m) SOUND ATTENUATORS, SOUND ATTENUATING OUVRES SUPPY AIR NOZZES EXTERNA EEMENTS AIR FOW CONTRO UNITS 1

Technical data Ventilating grilles AR-1, 1, 17, 18; JR-,, 7, 8; RR-1,,, 6; SK-2,,, 9 without ceiling effect (distance from ceiling 0.8 m) Table with correcting factors for horizontal air jet deflection: β α Blade adjusting angle β 90 Air jet spread angle α 60 Air flow velocity V V diag. x 0.7 x 0. Temperature factor Δt /Δt Z (Δt / Δt Z diag.) x 0.7 x 0. Induction i i diag. x 1. x 2.0 Air jet drop y y diag. x 1. x 2.0 Distance between grilles A 0.2 0. Chart for determining air jet deflection: Effective outlet area A (m 2 ef ) v (m/s) ef 0.00 0.01 0.0 0.1 0. 2 A (m ) ef t ( C) z heating (m) v (m/s) ef y 6 2 cooling 0.01 0.02 0.0 0.1 0.2 1.0 8 1 8 6 y y= x t z t z diag. Air jet drop/rise y/ t (m/ C) z Example Given: Air flow: Q = 60 m³/h, = m Air flow velocity: V = 0. m/s Temperature difference: Δt Z = C Solution: Use the chart, distance from ceiling 0.8 m and select the grille type AR-1 size B = 2, H = 12 Effective outlet air velocity V ef =. m/s Temperature factor Δt /Δt Z = 0.06 Temperature difference Δt = 0.06 x = 0.2 C Induction i = 2 Width of the air jet b 0.2 = 1.0 m Min. distance between grilles A = 2 m 2

Technical data Ventilating grilles AR-1, 1, 17, 18; JR-,, 7, 8; RR-1,,, 6 with ceiling effect (distance from ceiling 0. m) Chart for determining the size, induction and temperature of the air flow valid for B/H 12 fully opened blades 122 2 122 2 122 82 2 62 82 122 62 2 2 82 2 62 122 2 2 6 7 8 9 000 000 Effective discharge air velocity v ef (m/s) 2 1. 1 Induction i 2 1 2 0 Ventilating VENTIATING grilles, GRIES, Ventilating VENTIATING valves VAVES CIRCUAR DIFFUSERS, SQUARE DIFFUSERS SWIR DIFFUSERS, VARIABE SWIR DIFFUSERS Width B (mm) 2 82 2 62 122 2 2 2 82 2 62 2 22 2 2 22 2 2 2 22 12 7 Height H (mm) 00 100 00 800 600 00 00 00 0 10 Air flow Q (m /h) 0.6 0. 0. 0. 0.2 0.2 0.1 0.08 0.0 Temperature factor t tz SOT DIFFUSERS, ROUND DUCT DIFFUSERS AIR DISPACEMENT UNITS Air jet velocity v (m/s) 1.0 0.7 0. 0. 0. 0.2 1. Air jet width b 0.2 (m) 1.0 0.9 0.8 0.7 0.6 0. 1 9 8 7 6 Throw distance (m) 6 7 8 9 1 Throw distance (m) SUPPY AIR NOZZES EXTERNA EEMENTS Definition of symbols Q A 0.1 Q b 0.2 Occupied zone v (m/s) t ( C) v = 0.2 m/s 0.m Q (m /h) t ( C) Z Q (m³/h) (m) V ef (m/s) V (m/s) Δt z (K) Δt (K) i b 0.2 (m) Air flow Throw distance Effective discharge air velocity Max. air velocity at the throw distance Temperature difference between supply and room air Temperature difference between air jet and room temperature Induction rate = total airstream volume flow / volume flow at diffuser discharge Width of air jet is measured at a distance from ceiling where air flow velocity 0.2 m/s AIR FOW CONTRO UNITS SOUND ATTENUATORS, SOUND ATTENUATING OUVRES

Technical data Ventilating grilles AR-1, 1, 17, 18; JR-,, 7, 8; RR-1,,, 6 with ceiling effect (distance from ceiling 0. m) Chart for determining the size, induction and temperature of the air flow valid for B/H 12 fully opened blades Effective discharge air velocity v ef (m/s) Induction i 10 10 00 10 900 10 10 800 00 10 10 700 900 00 10 600 800 900 00 10 700 800 900 10 6 00 600 700 800 00 10 7 900 8 00 600 700 800 10 0 600 00 9 00 00 00 700 900 10 0 800 10 000 00 600 700 00 0 0 00 900 00 0 600 800 10 000 0 00 00 700 10 00 0 0 600 00 00 0 00 0 20 00 00 0 20 00 0 20 00 900 800 700 600 00 0 00 0 0 00 00 100 00 800 600 2 1. 1 0.6 0. 0. 0. 0.2 0.2 2 1 2 0 Width B (mm) 00 00 0 00 20 0 Height H (mm) 20 10 0 10 10 0 00 00 00 0 10 Air flow Q (m /h) 0.1 0.08 0.0 Temperature factor t z t Air jet velocity v (m/s) 1.0 0.7 0. 0. 0. 0.2 6 7 8 9 1 Throw distance (m) 1 1. Air jet width b 0.2 (m) 1.0 0.9 0.8 0.7 0.6 9 8 7 6 Throw distance (m) 0.

Technical data Table with correcting factors for horizontal air jet deflection β α Blade adjusting angle β 90 Air jet spread angle α 60 Air flow velocity V V diag. x 0.7 x 0. Temperature factor Δt /Δt Z (Δt / Δt Z diag.) x 0.7 x 0. Induction i i diag. x 1. x 2.0 Air jet drop y y diag. x 1. x 2.0 Distance between grilles A 0.2 0. Ventilating VENTIATING grilles, GRIES, Ventilating VENTIATING valves VAVES CIRCUAR DIFFUSERS, SQUARE DIFFUSERS Chart for determining air jet deflection 1 SWIR DIFFUSERS, VARIABE SWIR DIFFUSERS 2. Example Given: Air flow: Q = 60 m³/h, = m Air flow velocity: V = 0. m/s Temperature difference: Δt Z = C SOT DIFFUSERS, ROUND DUCT DIFFUSERS Max. temperature difference by cooling t z ( C) 2 1 0.00 ef v (m/s) 0.01 1 1. 0.0 2 0.1 0. Solution: Use the chart, distance from ceiling 0. m and select the grille type JR- size B = 62, H = 12 Effective outlet air velocity V ef = 2.8 m/s Temperature factor Δt /Δt Z = 0.1 Temperature difference Δt = 0.1 x = 0.6 C Induction i = 1 Width of the air jet b 0.2 = 1.0 m Min. distance between grilles A = 1. m AIR DISPACEMENT UNITS SUPPY AIR NOZZES 2 Effective outlet area A ef (m ) EXTERNA EEMENTS SOUND ATTENUATORS, SOUND ATTENUATING OUVRES AIR FOW CONTRO UNITS

Technical data Technical data for ventilating grilles Pressure drop in duct Δpcel (Pa) Pressure drop and sound power level diagram for grilles AR-6, 7, 8, 9, 1, 1, 17, 18, JR-,, 7, 8, RR-1,,, 6 with volume control damper F Fully opened blades Opened 0 2% 0% 0% 0 0 0 1 N R 2 0 0 2 WA (db(a)) 2 0 0 0 Effective air veloctiy v ef (m/s) Regulation set-up p cel Table of correction factors for acoustic data A ef (m²) 0.01 0.02 0.0 0.1 0.2 0. Correction (db(a)) N R - -7-0 + +6 Definition of symbols A ef Δp cel (Pa) WA (db(a)) N R Effective outlet area Pressure drop Sound power level Max. value acc. to ISO vef Room sound attenuation diagram 1 1 12 11 00 00 The following data are necessary to calculate the volume Q : 1. Normal rooms Q = Q 2. Rooms with highly reflective walls Q = 0.Q. Rooms with absorption walls Q = 2Q Room attenuation (db(a)) 9 8 7 6 Volume Q (m) 00 0 0 0 Definition of symbols Q (m³) Calculated volume, depending on room reflectance Q (m³) Actual room volume 2 1 0.7 1.0 2.0.0.0.0 Distance from ventilating element (m) 6

Technical data Technical data for extracting grilles Presure drop and sound power level for grilles AR-, 6, 7, 8, 9, 1, 1, 17, 18; JR-,, 7, 8 RR-1,,, 6 with volume control damper F Fully opened blades Pressure drop in duct Δpcel (Pa) 0 0 0 0 N R 2 0 0 2 WA (db(a)) 1 2 6 0 Effective air veloctiy v ef (m/s) 0 0 Opened 2% 0% 0% Regulation set-up v ef Table of correction factors for acoustic data p cel A ef (m²) 0.00 0.01 0.02 0.0 0.1 0.2 0. Correction (db(a)) N R -1 - -7-0 + +6 Ventilating VENTIATING grilles, GRIES, Ventilating VENTIATING valves VAVES CIRCUAR DIFFUSERS, SQUARE DIFFUSERS SWIR DIFFUSERS, VARIABE SWIR DIFFUSERS SOT DIFFUSERS, ROUND DUCT DIFFUSERS AIR DISPACEMENT UNITS Pressure drop and sound power level diagram for AR- grille with volume control damper F Horizontal blades 0 Opened 2% 0% SUPPY AIR NOZZES v ef Pressure drop in duct Δpcel (Pa) 0 0 0 N R 2 0 0 0 0 0% Regulation set-up p cel EXTERNA EEMENTS AIR FOW CONTRO UNITS 1 2 2 WA (db(a)) 6 Effective air veloctiy v ef (m/s) Definition of symbols Δp cel (Pa) Pressure drop WA (db(a)) Sound power level Max. value acc. to ISO N R SOUND ATTENUATORS, SOUND ATTENUATING OUVRES 7

Technical data Effective supply air velocity diagram Effective outlet area A ef (m/s) 0.00 0.01 0.02 0.0 0.0 0.0 0.1 0.2 0. 0. 0. 9 8 Example Effective intel air velocity vef (m/s) 7 6 Q = 00 m³/h A ef = 0.0 m³ (from the Effective area table) As follows from the diagram. V ef =. m/s 2 2 0 0 0 0 00 00 00 000 000 000 Air flow volume Q (m/h) Room sound attenuation diagram 1 1 12 11 00 00 The following data are necessary to calculate the volume Q : 1. Normal rooms Q = Q 2. Rooms with highly reflective walls Q = 0.Q. Rooms with absorption walls Q = 2Q Room attenuation (db(a)) 9 8 7 6 Volume Q (m) 00 0 0 0 Definition of symbols Q (m³) Calculated volume, depending on room reflectance Q (m³) Actual room volume 2 1 0.7 1.0 2.0.0.0.0 Distance from ventilating element (m) 8

Technical data Aluminium grilles AR-6, AR-7 with ceiling effect (distance from ceiling 0. m) Chart for determing the size, induction and temperature of the air flow valid for B/H 12 fully opened blades Ventilating VENTIATING grilles, GRIES, Ventilating VENTIATING valves VAVES 122 2 122 82 2 62 82 122 2 62 82 2 2 62 122 2 2 2 82 7 8 9 000 000 6 00 100 Effective discharge air velocity v ef (m/s) 2 1. 2 Induction i 1 0 0 CIRCUAR DIFFUSERS, SQUARE DIFFUSERS SWIR DIFFUSERS, VARIABE SWIR DIFFUSERS Width B (mm) 2 2 62 122 2 2 2 82 2 62 2 22 2 2 22 2 22 12 7 Height H (mm) 00 800 600 00 00 00 0 Air jet velocity v (m/s) 10 Air flow Q (m /h) 0. 0. 0.2 0.1 0.0 0.0 0.0 Temperature factor t tz SOT DIFFUSERS, ROUND DUCT DIFFUSERS AIR DISPACEMENT UNITS 1.0 0.7 0. 0. 0. 0.2 1. 1.0 0.90.8 Air jet width b 0.2(m) 0.7 0.6 0. 1 9 8 7 6 Throw distance (m) 6 7 8 9 1 Throw distance (m) SUPPY AIR NOZZES EXTERNA EEMENTS Q A 0.1 Q b 0.2 Bivalna cona Occupied zone v (m/s) t ( C) v = 0.2 m/s 0.m Q (m /h) t ( C) Z Definition of symbols Q (m³/h) (m) V ef (m/s) V (m/s) Δt z (K) Δt (K) i b 0.2 (m) Air flow Throw distance Effective discharge air velocity Max. air velocity at the throw distance Temperature difference between supply and room air Temperature difference between air jet and room temperature Induction rate = total airstream volume flow / volume flow at diffuser discharge Width of air jet is measured at a distance from ceiling where air flow velocity 0.2 m/s AIR FOW CONTRO UNITS SOUND ATTENUATORS, SOUND ATTENUATING OUVRES 9

Technical data Aluminium grilles AR-6, AR-7, AR-8, AR-9 without ceiling effect (distance from ceiling 0. m) Chart for determing the size, induction and temperature of the air flow valid for B/H 12 122 2 122 82 2 62 82 122 2 62 82 2 2 62 122 7 8 9 000 000 6 Effective discharge air velocity v ef (m/s) 2 1. 1 2 Induction i 2. 1 2 0 2 2 2 82 2 62 122 2 2 00 100 00 0.6 2 82 800 0. Weidth B (mm) 2 2 62 2 22 2 2 22 2 22 12 7 Height H (mm) 600 00 00 00 0 10 Air jet veloctiy v (m/s) Air flow Q (m /h) 0. 0.2 0.2 0.1 0.1 0.08 0.0 Temperature factor t tz 1.0 0.7 0. 0. 0. 0.2 1 6 7 8 9 Throw distance (m) 1 1. 1.0 Air jet width b 0.2 (m) 0.9 0.8 0.7 0.6 0. 9 8 7 6 Throw distancde (m) Definition of symbols Q (m³/h) (m) V ef (m/s) V (m/s) Δt z (K) Δt (K) i b 0.2 (m) Air flow Throw distance Effective discharge air velocity Max. air velocity at the throw distance Temperature difference between supply and room air Temperature difference between air jet and room temperature Induction rate = total airstream volume flow / volume flow at diffuser discharge Width of air jet is measured at a distance from ceiling where air flow velocity 0.2 m/s 0.2 A Q Q 0.2 b Occupied Bivalna cona zone v (m/s) t ( C) v = 0.2 m/s 0.8m Q (m /h) t ( C) Z 0

Technical data Aluminium and steel ceiling grilles SR-1, SR-2, SR-, SR-, SR-, SR-6, SR-7, SR-8 Chart for determing of effective outlet area, temperature and air flow induction Ventilating VENTIATING grilles, GRIES, Ventilating VENTIATING valves VAVES A ef (m2 ) 0. 0.2 7 Effective discharge air velocity v (m/s) 2 1. ef Induction i 1 CIRCUAR DIFFUSERS, SQUARE DIFFUSERS 0.1 0.0 000 00 0. SWIR DIFFUSERS, VARIABE SWIR DIFFUSERS 100 00 0.02 00 00 0.01 00 0.00 0 10 Air flow Q (m /h) 0. Temperature factor 0.2 t z t 0.1 0.07 0.0 7 1 SOT DIFFUSERS, ROUND DUCT DIFFUSERS AIR DISPACEMENT UNITS 1.0 0.8 0. 0. Air jet velocity v (m/s) 0. 0.2 1 Throw distance (m) SUPPY AIR NOZZES 7 Throw distance (m) EXTERNA EEMENTS E v (m/s) t ( C) =C+E C v (m/s) t ( C) v =0.2m/s (m) Q(m /h) t Z ( C) Izračun Calculation delnih of količin partial zraka: air flows SR-1, SR- Q1 = Qcel SR-2, SR-6 SR- SR- Q2 = Qcel 2 Q = Qcel x F 2F + F Q = Qcel x F 2(F + F) Q = Qcel x F 2F + F Q = Qcel x F 2(F + F) SR-7 Q = Qcel x F 2(F + F) Q = Qcel x F 2(F + F) SR-8 Q = Qcel x F Q = Qcel x F 2(F + F) 2(F + F) Definition of symbols Q (m³/h) Q cel(m³/h) A ef (m²) For every discharge field F1 F Is to be divided among every discharge field For particular discharge field F1 F according to table of standard dimensions AIR FOW CONTRO UNITS SOUND ATTENUATORS, SOUND ATTENUATING OUVRES 1

Technical data The data in diagram is valid for ceiling grilles SR-1, SR-2, SR-, SR-6, SR-7, SR-8. SR- F value only, SR- F, value only, where H 1 B 2.1 The data in square ceiling diffusers diagram are valid for: SR- F value only, SR- F value only, H 1 B 2.1 SR- F value only, where When using diagram for square diffusers, partial air flows Q and Q as well as partial areas for particular discharge fields F or. F are to be multiplied by. Use the area of xf or xf (for correspondent sizes 1-8). Definition of symbols Q (m³/h) (m) V (m/s) V h (m/s) Δt ( C) Δt z ( C) i b 0.2 (m) Air flow Throw distance: /= C + E Max. air velocity at the throw distance Vertical velocity at distance h from ceiling by combining two counterdirectional air jets Temperature difference between air jet and room temperature Temperature difference between supply and room air Induction rate = total airstream volume flow / volume flow at diffuser discharge Width of air jet is measured at a distance from ceiling where air flow velocity 0.2 m/s Pressure drop diagram: Valid for F 2 in F volume control dampers. 0 2% Opened 0% 0% Vertical velocity diagram Max. temperature quotient Δt h/δt z is determined with the basic diagram for temperature quotient, where: 2.0 0 Pressure drop Δpcel (Pa) 0 0 R N =2 0 0 2 0 0 WA (db(a)) Regulation set-up Distance from ceiling h (m) 1. 1.0 0.8 2 6 p cel 0. 0. 0. Air jet velocity 0.8(m/s) 0.7 0.6 0.2 Effective discharge air velocity v ef (m/s) 0.1 0.2 0. 0. 0. 0.7 Vertical velocity v h (m/s) v h Example v (m/s) h t h( C) Given: Ceiling grille SR-/F2 size B = 1271 mm, H = 76 mm, Q cel = 107 m³/h. Effective areas of discharge fields according to table of standard dimensions: F = 0.072 m², F = 0.011 m² Calculation of partial air flows: 107 x 0.072 Q = 2 x 0.072+0.011 = 700 m³/h 107 x 0.011 Q = 2 x 0.072+0.011 = 7 m³/h As follows from the ceiling grilles diagram: = 7.1 m, v = 0. m/s, v ef = 2.8 m/s As follows from the square diffusers diagram: size, Q = x7 = 28 m³/h, = 1. m, v = 0. m/s, v ef = 2.8 m/s 2

Grilles with thermostatic regulation Grilles with thermostatic regulation Aluminium grille with thermostatic regulation AR-18/TR Steel grille with thermostatic regulation JR-8/TR AI St RA 90 Ventilating VENTIATING grilles, GRIES, Ventilating VENTIATING valves VAVES CIRCUAR DIFFUSERS, SQUARE DIFFUSERS SWIR DIFFUSERS, VARIABE SWIR DIFFUSERS The grille is intended for air supply. The first row of vertical blades can be set freely while the second row of horizontal blades is set automatically and adapted to the temperature of the supplied air. As long as the air temperature does not reach C the blades are directed at above the horizontal position. In the range between C and 0 C the blades are set automatically according to the characteristic of the thermostatic element. When the air temperature reaches or exceeds 0 C the blades are directed at below the horizontal position. Depiction of blade angles at different temperatures of supplied air T < C SOT DIFFUSERS, ROUND DUCT DIFFUSERS AIR DISPACEMENT UNITS Description AR-18/TR grille is made of aluminum anodized extruded profiles. A visible screw fastening with screws on the grille frame is projected. Adjusting part S. can be used to adjust air flow. JR-8/TR grille is made of steel sheet. Blades in the second row are made of aluminum anodized profile. The whole grill is powder painted in RA 90 or in the colour requested by buyer. Diagram: blade angles depending on the temperature of supplied air T > 0 C T = -0 C SUPPY AIR NOZZES EXTERNA EEMENTS Blade angles ( ) 0 0 0 2 1 21 22 2 2 2 26 28 0 Temperature ( C) AIR FOW CONTRO UNITS SOUND ATTENUATORS, SOUND ATTENUATING OUVRES

Grilles with thermostatic regulation Installation of grilles with screws on the frame h Visible screw installation / V B1 = B-27 H1 = H-27 AR-18/TR, JR-8/TR h = 6 mm Marking: AR-18/TR/V, JR-8/TR/V H-/B- H1/B1 28 Dimensions and clean cross sections in m²: B/H 17 22 2 2 2 2 0.029 0.09 0.061 0.082 2 0.09 0.0 0.082 0.111 0.10 62 0.00 0.068 0. 0.10 0.177 72 0.060 0.082 0.126 0.170 0.21 82 0.070 0.096 0.17 0.199 0.20 92 0.081 0.1 0.169 0.228 0.287 2 0.091 0.12 0.191 0.27 0.2 112 0.2 0.19 0.212 0.286 0.60 122 0.112 0.1 0.2 0.1 0.97 90 B1 B1+ H1 H1+ Ordering key JR-8 / TR / V S B x H S Register S V Visible screw installation TR Thermostat regulation JR-8 Grille type AR-18 Grille type

Special grilles Special grilles Ventilating VENTIATING grilles, GRIES, Ventilating VENTIATING valves VAVES Grease traps M-1, M-2 Application Grease traps are used to extract air from kitchens and rooms with a high level of greasy steam. A special grease filter reduces the soiling of air ducts and ventilators. Grease traps permit no air flow regulation. Housing with groove is made of sheet steel and coloured in black. Description Filter consists of frame and infill made of expanded sheet aluminium. Construction made of stainless steel is available on request. Filter is easy to dismantle and wash in hot lye or other wash solutions (detergents). M-1 M-1 grease trap is designed for wall mounting. Extracted grease accumulates in special groove. Installation a) Installation in solid wall via the built-in frame. Designation M-1/2 28 St 27 H1 27 0 27 B1 27 Technical data Diagram shows the pressure drop at the cross section B1xH1. Recommended air velocity is between 1 m/s and 2 m/s. Diagram is valid for M-1 and M-2. A ef=000/(b1-28xh-12)x0 2(vm²) 0 Dimensions B B1 H H1 2 97 22 197 62 97 82 797 2 997 2 97 2 297 62 97 82 797 CIRCUAR DIFFUSERS, SQUARE DIFFUSERS SWIR DIFFUSERS, VARIABE SWIR DIFFUSERS SOT DIFFUSERS, ROUND DUCT DIFFUSERS AIR DISPACEMENT UNITS SUPPY AIR NOZZES H1/B1 28 H-/B- b) Direct installation in sheet steel duct. Designation M-1 Pressure drop Δpt (Pa) 0 0 0 2 997 2 97 2 97 62 97 82 797 2 997 EXTERNA EEMENTS AIR FOW CONTRO UNITS H1/B1 H-7/B- 1 2 Effective discharge air velocity v ef (m/s) SOUND ATTENUATORS, SOUND ATTENUATING OUVRES

Special grilles M-2 Grase trap M-2 is designed for ceiling installation. Extracted grease accumulates in special tube. Installations a) Installation in solid wall via the built-in frame. Designation M-2/2 St RA 90 H-1/B-1 27 B1 27 Dimensions H+70/B+70 b) Installation in sheet steel duct. Designation M-2/2 H-/B- 27 H1 27 B B1 H H1 2 97 22 197 62 97 82 797 2 997 2 97 2 297 62 97 82 797 2 997 2 97 2 97 62 97 82 797 2 997 H+70/B+70 8 Ordering example Grease trap: M-1 / 2 Size: B = 2 H = 22 Pcs: 6 6

Special grilles Filter grilles /PF Application Grilles with pre-filter are designed for application in rooms with special demands (computer centres, libraries, archives). Description Filter housing is designed to fit all sizes of ventilating grilles. It consists of galvanized sheet steel. Air volume is controlled by the means of F or T type air volume damper. Filter class G2 to F. Filter builds up the initial pressure of 0Pa by the air flow volume of 00 m³/h and air velocity V ef = 1. m/s (at the grille). In the course of time, when filter gets dirty, pressure drop is increased. F EU... St AI RA 90 AR-1,1,17,18, JR-,,7,8 RR-1,,,6 AR-,,,6,7 Ventilating VENTIATING grilles, GRIES, Ventilating VENTIATING valves VAVES CIRCUAR DIFFUSERS, SQUARE DIFFUSERS SWIR DIFFUSERS, VARIABE SWIR DIFFUSERS Filter replacement When replacing the filter, remove the grille and take out the filter infill. Replace used filter infill with new one of the same quality. Fasten the new infill in the housing and finally replace the grille. H- / B- H-1 / B-1 SOT DIFFUSERS, ROUND DUCT DIFFUSERS Installation Filter housing can be built-in or screwed in the duct. Grill is mounted on the filter housing: 1 1. with screws on the frame (AR, JR) PF/V 2. with locks (hidden installation) (AR, JR) PF/2 AIR DISPACEMENT UNITS Ordering example Ventilating grille: With pre-filter: AR-1PF/G2/2 F Size: B = 82 H = 12 Filter quality: G2, G, G, F Pcs: SOUND ATTENUATORS, SOUND ATTENUATING OUVRES AIR FOW CONTRO UNITS SUPPY AIR NOZZES EXTERNA EEMENTS 7

Special grilles inear grilles T Application When there is a demand to assembly grilles in longer linear lines, linear grilles should be used. St RA 90 AI Description ine is divided into approx. equal elements of 1. m. The elements are connected with special partition bars. Band grilles types AR-6, 7, 8, 9, 1, 1, JR-,. AR-6, AR-7 AR-6, AR-7 B- / H- B1/ B1/ B1/ Installation type example Visible screw connection with screws in the frame designation: AR-1T/V Hidden installation with built-in frame and locks designation: AR-1T/2 AR-8, AR-9 Regulation The same registers as for basic grilles. See table on the page 27. (B+)/ (B+)/ (B+)/ B / H AR-1, AR-1, JR-, JR- B- / H- B1/ B1/ B1/ Connection AR-1, JR- Connection AR-1, JR- Ordering key AR-6T/2-F B x H F Register 2 Hidden screw installation V Visible screw installation T inear version 6 Grille type AR-6, 7, 8, 9, 1, 1, JR-, 8

Special grilles Blade inserts Application They are designed for installation in existing frame. Inserts allow smaller loads why they can not suspend the weight of cars and trucks. AI B 0 0 H T 1 2 Ventilating VENTIATING grilles, GRIES, Ventilating VENTIATING valves VAVES CIRCUAR DIFFUSERS, SQUARE DIFFUSERS Forms and dimensions of blades: T1 = T = 12. mm T2 = T = 16.7 mm 1. Blade 2. Support SWIR DIFFUSERS, VARIABE SWIR DIFFUSERS AR-6V AR-6V1 AR-7V.. SOT DIFFUSERS, ROUND DUCT DIFFUSERS Inserts are anodised in the following colours: A golden colour (C), B black colour (C), C brass colour (C), D natural Al colour (C0). Upon customer s request, blade inserts can be powder painted in RA colours. Ordering key AR-6V1/T1/A B x H Max. size of grille is: B max = 000 mm H max = 00 mm Smaller dimensions B x H are possible. AIR DISPACEMENT UNITS SUPPY AIR NOZZES EXTERNA EEMENTS Colour Distance between blades: T1 = 12. mm T2 = 16.7 mm Forms of blades: AR-6V AR-6V1 AR-7V AIR FOW CONTRO UNITS SOUND ATTENUATORS, SOUND ATTENUATING OUVRES 9

Plenum box for grilles Plenum box for grilles Plenum boxes Plenum box is designed for connection of ventilation grilles to the ventilation network. The most important function of plenum box is to create an even field of over- or underpressure (outlet) all over the effective outlet area of the grille. The construction of plenum box enables visible as well as hidden installation. Plenum box is made of galvanised sheet steel. Top entry spigot V Side entry spigot S Sizes Size B and H are the standard grille dimensions. Height of the plenum box h as well as entry spigot diameter фd is to be stated in order. h 0 v s φd φd Plenum box for the grilles stated below AR-,, 6, 7, 1, 1, 17, 18, JR-,, 7, 8, RR-1,,, 6, SR, 6, 7, 8 11 B/H 11 Installation: Hidden assembly Visible assembly Ordering key Plenum box 62 x 22 / S / 1 x ф d 18 / h = 270 h Plenum box height фd E ntry spigot diameter 1 Number of spigots 2 S Side entry spigot V Top entry spigot Grille size BxH 0

Plenum box for grilles Table of recommended dimensions for the S version B H h* d* 22 7 270 18 2 18 2 18 2 18 62 18 82 2x18 2 2x18 122 2x18 10 0 270 18 0 18 20 18 00 18 0 18 00 18 0 18 00 18 600 18 700 18 800 2x18 900 2x18 00 2x18 10 2x18 10 2x18 22 12 270 18 2 18 2 18 2 18 62 18 82 2x18 2 2x18 122 2x18 10 10 270 18 0 18 20 18 00 18 0 18 00 18 0 18 00 18 600 18 700 18 800 2x18 900 2x18 00 2x18 10 2x18 10 2x18 0 0 270 18 20 18 00 18 0 18 00 18 0 18 00 18 600 18 700 18 800 2x18 900 2x18 00 2x18 10 2x18 10 2x18 h* recommended dimensions d* recommended dimensions B H h* d* 22 22 270 18 2 18 2 18 2 18 62 18 82 2x18 2 2x18 122 2x18 20 20 270 18 00 18 0 18 00 18 0 18 00 18 600 18 700 18 800 2x18 900 2x18 00 2x18 10 2x18 10 2x18 00 00 0 198 0 198 00 198 0 198 00 198 600 198 700 198 800 2x198 900 2x198 00 2x198 10 2x198 10 2x198 2 2 0 198 2 198 2 198 62 198 82 2x198 2 2x198 122 2x198 0 0 0 198 00 198 0 198 00 198 600 198 700 198 800 2x198 900 2x198 00 2x198 10 2x198 10 2x198 B H h* d* 00 00 80 28 0 28 00 28 600 28 700 28 800 2x28 900 2x28 00 2x28 10 2x28 10 2x28 2 2 80 28 2 28 62 28 82 2x28 2 2x28 122 2x28 00 00 0 298 600 298 700 298 800 2x298 900 2x298 00 2x298 10 2x298 10 2x298 2 2 0 298 62 298 82 2x298 2 2x298 122 2x298 Ventilating VENTIATING grilles, GRIES, Ventilating VENTIATING valves VAVES CIRCUAR DIFFUSERS, SQUARE DIFFUSERS SWIR DIFFUSERS, VARIABE SWIR DIFFUSERS SOT DIFFUSERS, ROUND DUCT DIFFUSERS AIR DISPACEMENT UNITS SUPPY AIR NOZZES EXTERNA EEMENTS AIR FOW CONTRO UNITS SOUND ATTENUATORS, SOUND ATTENUATING OUVRES 1

Ventilating valve Ventilating valve PV-1N Description Fixed diffusion ring Adjustable disc for valve opening and closing Installation in built-in frame Peripheral foamy sealing strip Exhaust application St RA 90 1 2 Material Made of sheet steel and coloured upon customer s request. Component parts 1. Housing 2. Valve disc. Subframe Installation Frame is suitable for all installation types (wall, ceiling-or duct installation). It is fastened with screws. Place the valve in the groove and rotate it. Foamy sealant between the subframe and valve has a function to guarantee a perfect seal and to hold the valve in its position. φb Air flow regulation Adjust the air volume flow by rotating the valve disc in plus or minus direction. - S + s (mm) S S Dimensions: Size ΦB 0 0 12 12 10 10 160 160 0 0 Ordering example Ventilating valve: PV-1N Size: 0 Pcs: 0 2

Ventilating valve PV-1N, size 0 00-6 - 0 + +6 PV-1N, size 12 00-6 - 0 Ventilating VENTIATING grilles, GRIES, Ventilating VENTIATING valves VAVES Δp t (Pa) 0 0 d B (A ) W A 0 0 +12 Δp t (Pa) 0 0 d B (A ) W A 0 0 + +6 +12 CIRCUAR DIFFUSERS, SQUARE DIFFUSERS Pressure drop 0 0 0 Pressure drop 0 0 0 SWIR DIFFUSERS, VARIABE SWIR DIFFUSERS Air flow Q ( m/h) Air flow Q ( m/h) PV-1N, size 10 00-6 - 0 PV-1N, size 160 00-6 - 0 + +6 SOT DIFFUSERS, ROUND DUCT DIFFUSERS 0 0 d B (A ) W A 0 0 + +6 +12 0 0 d B (A ) W A 0 0 +12 AIR DISPACEMENT UNITS Δp t (Pa) Pressure drop 60 0 0 Δp t (Pa) Pressure drop 70 0 0 20 280 SUPPY AIR NOZZES Air flow Q ( m/h) Air flow Q ( m/h) PV-1N, size 0 Pressure drop Δp t (Pa) 00 0 0 d B (A ) -6-0 + 0 0 0 00 Air flow Q ( m/h) W A 0 0 +6 +12 00 Example Use the air flow volume Q (m³/h) and pressure drop over the valve ΔP t (Pa) to determine the valve set-up s (mm) using the positive or negative direction. Given data: Q = 70m³/h, ΔP t = 60Pa Sizing diagram at the value 0 gives the valve set-up s = 0 mm. Definition of symbols Q (m³/h) Δp t (Pa) WA (db(a)) Air flow Pressure drop Sound power level EXTERNA EEMENTS AIR FOW CONTRO UNITS SOUND ATTENUATORS, SOUND ATTENUATING OUVRES

Ventilating valve PV-2N Description Fixed diffusion ring Adjustable disc for valve opening and closing Installation in built-in frame Peripheral foamy sealing strip Supply application St RA 90 1 2 φb Material Made of sheet steel and coloured upon customer s request. Component parts 1. Housing 2. Valve disc. Subframe Installation Frame is suitable for all installation types (wall, ceiling-or duct installation). It is fastened with screws. Place the valve in the groove and rotate it. Foamy sealant between the subframe and valve has a function to guarantee a perfect seal and to hold the valve in its position. Air flow regulation Adjust the air volume flow by rotating the valve disc in plus or minus direction. - S + s (mm) S S Dimensions: Size ΦB 0 0 12 12 10 10 160 160 0 0 Ordering example Ventilating valve: PV-2N Size: 0 Pcs: 0

Ventilating valve PV-2N, size 0 00-6 - 0 + PV-2N, size 12 00-6 - 0 + Ventilating VENTIATING grilles, GRIES, Ventilating VENTIATING valves VAVES Pressure drop Δp t (Pa) Pressure drop Δp t (Pa) Pressure drop Δp t (Pa) 0 0 0 0 0 0 0 0 0 20 Air flow Q (m/h) Air flow Q (m/h) PV-2N, size 10 00 0 0 60 0 0 20 70 0 0 20 Air flow Q (m/h) Air flow Q (m/h) PV-2N, size 0 00 0 0 W A d B (A ) -6-0 70 0 0 00 Air flow Q ( m/h) d B (A ) W A W A d B (A ) 0 0 0 0-6 +6 +12 00-0 + +6 +12 +6 +12 Δp t (Pa) Pressure drop Δp t (Pa) Pressure drop 0 0 PV-2N, size 160 00 0 0 d B (A ) Definition of symbols Q (m³/h) Δp t (Pa) WA (db(a)) W A Air flow Pressure drop Sound power level d B (A ) W A 0 0 0 +6 +12-6 - 0 + +6 +12 CIRCUAR DIFFUSERS, SQUARE DIFFUSERS SWIR DIFFUSERS, VARIABE SWIR DIFFUSERS SOT DIFFUSERS, ROUND DUCT DIFFUSERS AIR DISPACEMENT UNITS SUPPY AIR NOZZES EXTERNA EEMENTS AIR FOW CONTRO UNITS SOUND ATTENUATORS, SOUND ATTENUATING OUVRES

Ventilating valve PV- Application These valves are designed for business and residential use.they are suitable for wall or ceiling mounting. Meticulous workmanship allows inconspicuous installation. B A Description Two variants: exhaust and supply Sizes: Φ0, Φ12 mm, Φ160 mm Easy installation Environment friendly C Material The ventilating valve is made of antistatic ABS plastics. Installation The valve may be wall- or ceiling-mounted. In the case of a supply valve, set the regulator to stage 1, 2 or, depending on the desired flow rate. A standard exhaust PV- valve is not fitted with a deflector. The valve housing can be fitted with the RP-M air flow rate regulator. Standard dimensions Φ0 Φ12 Φ160 A 18 18 20 B 98 12 18 C 8 8 7 Valve tests were carried out on ceiling-mounted valves, set to stage 1. Definition of symbols Exhaust Q Φ 0 basic element Φ 0 + RP-M m³/h P (Pa) w (db(a)) P (Pa) w (db(a)) 1 0. < 0 27 < 0 7 60. 22 0 0 Q Φ 12 basic element Φ 12 + RP-M m³/h P (Pa) w (db(a)) P (Pa) w (db(a)) 60 < 0 2 90 11 2 0 6 1 29 0 1 Supply Q Φ 0 basic element Φ 0 + RP-M m³/h P (Pa) w (db(a)) Throw P (Pa) w (db(a)) 1 0. < 2,2 0 7 <,2 0 2 60. 22,1 0 1 Δp (Pa) WA (db(a)) Pressure drop Sound power level Q Φ 12 basic element Φ 12 + RP-M m³/h P (Pa) w (db(a)) Throw P (Pa) w (db(a)) 60 <,8 0 7 90 11 2, 0 2 1 28 6,2 0 1 Q Φ 160 basic element m³/h P (Pa) w (db(a)) 1 18 2, 1 28 60, 6

Ventilating valve Accessories RP-M REGUATOR for mounting on the PV- housing Φ0 mm: 1 do 60 m³/h Φ12 mm: 1 do 1 m³/h Sold separately RP-M/K REGUATOR for duct mounting Φ0 mm: 1 do 60 m³/h Φ12 mm: 60 do 1 m³/h Φ160 mm: 1 do 2 m³/h Sold separately MOUNTING FRAME Φ0 mm: length 10 mm Φ12 mm: length 10 mm Φ160 mm: length 10 mm Sold separately RP-M/K Flow rate (m³/h) Φ80 1 0 / / / / / / Φ0 1 0 60 7 90 / / / Φ12 1 0 60 7 90 1 10 180 Φ160 1 10 180 2 20 270 00 / / Φ0 2 20 270 00 0 00 0 00 / Φ20 00 0 00 0 00 600 60 700 / RPM: Size D1 (mm) D2 (mm) (mm) 80 76 7 0 96 9 60 12 1 117 90 10 18 17 97 160 16 17 97 0 196 192 90 20 2 2 9 Size Flow rate (m³/h) 80 1 0 - - - - - - 0 1 0 60 7 90 - - - 12 1 0 60 7 90 1 10 180 160 1 10 180 2 20 270 - - - 0-20 270 00 0 00 0 00-20 00 0 00 0 00 - - - - Flow Sound power level w (db(a)) rate (m³/h) 0 Pa 0 Pa 10 Pa 0 Pa 1 2 29 2 0 26 1 8 27 6 9 60 2 7 9 2 7 2 7 0 2 90 2 8 1 1 0 9 2 10 7 1 180 0 7 2 0 2 20 1 7 270 7 9 00 7 2 0 0 7 00 7 2 0 0 8 6 1 00 9 6 8 Ordering key PV- / RP-M Size 0, 12, 160 Ordering key RP-M/K Size 80, 0, 12, 160, 0, 20 D1 RP-M Flow rate regulator for PV- housing mounting RP-M/K Flow rate regulator with a duct mounting bracket VO Mounting frame BM White marble O Wood walnut R Wood red pine PR Pastel yellow PZ Pastel green PM Pastel blue PV- Flow rate regulator with a duct mounting bracket D2 Ventilating VENTIATING grilles, GRIES, Ventilating VENTIATING valves VAVES CIRCUAR DIFFUSERS, SQUARE DIFFUSERS SWIR DIFFUSERS, VARIABE SWIR DIFFUSERS SOT DIFFUSERS, ROUND DUCT DIFFUSERS AIR DISPACEMENT UNITS SUPPY AIR NOZZES EXTERNA EEMENTS AIR FOW CONTRO UNITS SOUND ATTENUATORS, SOUND ATTENUATING OUVRES 7

Staircase swirl diffuser Staircase swirl diffuser Staircase swirl diffuser STD-1 STD-1/KK STD-1/KR STD-1/RR Application Staircase swirl diffusers STD-1 are ideal for use in theatres, auditoria, concert halls, cinemas, etc. They can be installed vertically in steps or floors which do not carry foot traffic. STD-1/KK STD-1/KR STD-1/RR Description They are made of sheet steel and powder coated with RA 90 or RA 900. Installation Floor installation or installation into steps. 1 180 1 180 1 180 STD-1/ /V STD-1/.../V φ 12 STD-1/ /T STD-1/.../T 1 6 0-2 Installation: Vgradnja Floor Vgradnja installation: v v tla: tla: Stair Vgradnja installation: v v stopnice: V h1 V h1 Δt Δt h1 h1 V h1 V h1 Δt Δt h1 h1 h1 h1 h h X X h1 h1 V V (m (m /h) /h) pretok na na difuzorju V V (l/s) (l/s) pretok na na difuzorju Ordering key h h (m) (m) višina višina vgradnje nad nad tlemi tlemi STD-1 (m) (m) / KK oddaljenost / V od od difuzorja (=h+x) hh 1 (m) 1 (m) razdalja merilne točke točke od od tal tal VV h1 (m/s) h1 povprečna hitrost Installation zraka zraka na na razdalji h1 h1 od od tal tal * Δt * Δt Z (K) Z (K) temperaturna V razlika Visible med installation med temperaturo dovodnega zraka zraka in in zraka zraka v v prostoru * Δt * Δt h1 (K) h1 (K) razlika med med povprečno T Installation with cross bar temperaturo na na višini višini h1 h1 in in temperaturo v v prostoru Δp Δp t (Pa) t (Pa) padec tlaka tlakakk Square diffuser plate, square blade arr. WA (db(a) WA A-utežena zvočna moč KR Square moč diffuser plate, radial blade arr. WNC NC WNC NC nivo nivo zvočne RR Circular moči moči diffuser plate, radial blade arr. WNR = + 22 WNR WNR WNR WNC WNC pa, pa, pnc nivo pnc nivo zvočnega STD-1tlaka Diffuser tlaka utežen type po po A A krivulji ali ali NC NC nivo nivo v v odvisnosti od od prostora pa pa pwa - pwa - 88 db db pnc pnc pwnc - pwnc - 88 db db 8 * * Temperatura v v prostoru merjena od od 11 do do 1. 1. m od od tal! Ključ tal! Ključza zanaročanje: