A Stability Indicating UPLC Method for Candesartan in Bulk Drug Samples

Similar documents
Journal of Chemical and Pharmaceutical Research

CHAPTER INTRODUCTION OF DOSAGE FORM AND LITERATURE REVIEW

CHAPTER - IV. Acharya Nagarjuna University, Guntur 105

A Simple, Novel Validated Stability Indicating RP-HPLC method for estimation of Duloxetine HCl in Capsule Pharmaceutical Formulation

7. Stability indicating analytical method development and validation of Ramipril and Amlodipine in capsule dosage form by HPLC.

Int. J. Pharm. Sci. Rev. Res., 30(2), January February 2015; Article No. 09, Pages: 63-68

Available online Research Article

Volume 6, Issue 2, January February 2011; Article-015

Validation of Stability-Indicating RP-HPLC Method for the Assay of Ibrutinib in Pharmaceutical Dosage form

Validated RP-HPLC Method for Estimation of Cefprozil in Tablet Dosage Form

Impact factor: 3.958/ICV: 4.10 ISSN:

STABILITY INDICATING METHOD OF RELATED IMPURITIES IN VENLAFAXINE HYDROCHLORIDE SUSTAINED RELEASE TABLETS

Stability-indicating HPLC determination of tolterodine tartrate in pharmaceutical dosage form

DEVELOPMENT AND VALIDATION OF A STABILITY-INDICATING RP-HPLC METHOD FOR ASSAY OF IRBESARTAN IN PURE AND PHARMACEUTICAL DOSAGE FORM

STABILITY INDICATING RP HPLC METHOD FOR ANALYSIS OF DORZOLAMIDE HCl IN THE BULK DRUG AND IT S PHARMACEUTICAL DOSAGE FORM

Research Article METHOD DEVELOPMENT AND VALIDATION FOR SIMULTANEOUS ESTIMATION OF ELBASVIR AND GRAZOPREVIR BY RP-HPLC

International Journal of Pharmaceutical Sciences and Drug Research 2016; 8(4):

Method Development and Validation for the Estimation of Darunavir in Rat Plasma by RP-HPLC

Aripiprazole is a quinolinone derivative with the chemical name 7-[4- [4-(2,3-dichlorophenyl)-1-piperazinyl]butoxy]-3,4-dihydro-2(1H)

DETERMINATION OF DRUG RELEASE DURING DISSOLUTION OF NICORANDIL IN TABLET DOSAGE FORM BY USING REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

Method Development and Validation Of Prasugrel Tablets By RP- HPLC

A RP-HPLC METHOD DEVELOPMENT AND VALIDATION OF PARA- PHENYLENEDIAMINE IN PURE FORM AND IN MARKETED PRODUCTS

Development and Validation of Stability Indicating RP-HPLC Method for the Determination of Anagrelide HCl in Pharmaceutical Formulation

A Novel Stability Indicating Chromatographic Method Development And Validation For The Quantification of Tofacitinib In Pure And Its Dosage Form

J Pharm Sci Bioscientific Res (4): ISSN NO

Journal of Pharmaceutical and Biomedical Analysis Letters. Analysis Letters

STABILITY INDICATING RP-HPLC METHOD FOR DETERMINATION OF EPROSARTAN IN PURE AND PHARMACEUTICAL FORMULATION

International Journal of Pharmacy and Pharmaceutical Sciences Vol 2, Issue 1, 2010

Praveen kumar.m 1 *, Sreeramulu.J 2. *Corres.author: Mobile no: India.

VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION

A VALIDATED NON-AQUEOUS POTENTIOMETRIC TITRATION METHOD FOR QUANTITATIVE DETERMINATION OF CANDESARTAN CILEXETIL FROM PHARMACEUTICAL PREPARATION

Development and Validation of Stability-Indicating RP-HPLC Method for Estimation of Atovaquone

Pelagia Research Library

International Journal of Research in Pharmaceutical and Nano Sciences Journal homepage:

RP-HPLC Method Development and Validation of Dapagliflozin in Bulk and Tablet formulation

Available online at Scholars Research Library

ISSN : A validated stability-indicating RP-HPLC assay method for amsacrine and its related substances

Journal of Chemical and Pharmaceutical Research, 2017, 9(10): Research Article

2.1 2,3 Dichloro Benzoyl Cyanide (2,3 DCBC) and survey of. manufactured commonly for the bulk drug industry, few references were

Department of Quality Assurance, Luqman College of Pharmacy, GULBARGA (K.S.) INDIA ABSTRACT

Development and validation of RP-LC method for lisinopril dihydrate in bulk and its pharmaceutical formulations

Development of Validated Analytical Method of Mefenamic Acid in an Emulgel (Topical Formulation)

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD TO DETERMINE CINITAPRIDE HYDROGEN TARTARATE IN BULK AND PHARMACEUTICAL FORMULATION

Dissolution study and method validation of alprazolam by high performance liquid chromatography method in pharmaceutical dosage form

International Journal of Research in Pharmaceutical and Nano Sciences Journal homepage:

SIMULTANEOUS RP HPLC DETERMINATION OF CAMYLOFIN DIHYDROCHLORIDE AND PARACETAMOL IN PHARMACEUTICAL PREPARATIONS.

RP-HPLC METHOD FOR THE ESTIMATION OF ZIPRASIDONE

Isocraticc Reverse Phase HPLC Method-Determination and Validation of Cilostazol

Simultaneous estimation of ramipril and valsartan by RP-HPLC method in combined. dosage form

Novus International Journal of Analytical Innovations 2012, Vol. 1, No. 3

Stability Indicating RP-HPLC Method for Determination of Valsartan in Pure and Pharmaceutical Formulation

Simultaneous Estimation of Residual Solvents (Isopropyl Alcohol and Dichloromethane) in Dosage Form by GC-HS-FID

Reverse Phase High Performance Liquid Chromatography method for determination of Lercanidipine hydrochloride in bulk and tablet dosage form

WORLD JOURNAL OF PHARMACEUTICAL AND MEDICAL RESEARCH

Journal of Advanced Scientific Research DEVELOPMENT AND VALIDATION OF STABILITY-INDICATING RP-HPLC METHOD FOR ESTIMATION OF DABIGATRAN ETEXILATE

Development and Validation of Stability Indicating Assay Method of Etodolac by using UV-Visible Spectrophotometer

Research Article. Figure 1. Chemical structure of doxofylline. Indonesian J. Pharm. Vol. 24 No. 1 : ISSN-p :

Available online Research Article

Sravani and Haritha Indian Journal of Research in Pharmacy and Biotechnology ISSN: (Print) ISSN: (Online)

Low-level Determination of 4-Hydrazino Benzoic Acid in Drug Substance by High Performance Liquid Chromatography/Mass Spectrometry

Chapter 5. Irbesartan. Page no. 64 to 80

Journal of Drug Delivery and Therapeutics

Development and Validation of Sensitive RP-HPLC Method for the Estimation of Glibenclamide in Pure and Tablet Dosage Forms

New Validated RP-HPLC Method for Quantification of Rupatadine Fumarate Impurities in Solid Dosage Form Supported By Forced Degradation Studies

Available online Research Article

Analytical Method Development and Validation of Lafutidine in Tablet dosage form by RP-HPLC

DEVELOPMENT OF RP-HPLC METHOD FOR THE SIMULTANEOUS ESTIMATION OF CANDESARTAN CILEXETIL AND HYDROCHLOROTHIAZIDE IN PHARMACEUTICAL DOSAGE FORMS

Development and validation a RP-HPLC method: Application for the quantitative determination of quetiapine fumarate from marketed bulk tablets

Received: ; Accepted:

Journal of Chemical and Pharmaceutical Research, 2016, 8(10): Research Article

Scholars Research Library

A VALIDATED STABILITY-INDICATING HPLC ASSAY DETERMINATION OF FESOTERODINE FUMARATE

PHARMA SCIENCE MONITOR

Pelagia Research Library

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR QUANTITATIVE ANALYSIS OF GABAPENTIN IN PURE AND PHARMACEUTICAL FORMULATIONS

Journal of Chemical and Pharmaceutical Research

Method Development, Validation and Stability Study of Irbesartan in Bulk and Pharmaceutical Dosage Form by UV-Spectrophotometric Method

ANALYTICAL METHOD DEVELOPMENT AND VALIDATION OF IVABRADINE HCL IN BULK AND FORMULATION

Stability indicating RP-HPLC method for determination of azilsartan medoxomil in bulk and its dosage form

Section (i): Brief account of Dexlansoprazole

RP-HPLC Method for Simultaneous Estimation of Atenolol, Hydrochlorothiazide and Losarton in Tablet Dosage form

SIMPLE AND SENSITIVE VALIDATED REVERSE PHASE HPLC-UV METHOD FOR THE DETERMINATION OF LYMECYCLINE IN PHARMACEUTICAL DOSAGE FORMS

Journal of Chemical and Pharmaceutical Research, 2012, 4(6): Research Article. Estimation of zaleplon by a new RP-HPLC method

Pelagia Research Library

Journal of Chemical and Pharmaceutical Research

Application Note. Author. Abstract. Pharmaceutical QA/QC. Siji Joseph Agilent Technologies, Inc. Bangalore, India

Impact factor: 3.958/ICV: 4.10 ISSN:

Development And Validation Of Rp-Hplc Method For Determination Of Velpatasvir In Bulk

Mashhour Ghanem 1 and Saleh Abu-Lafi 2 * ABSTRACT ARTICLE INFO

Sarojamma. M et al, JGTPS, 2015, Vol. 6(2):

Development and Validation of a HPLC Method for Determination of Anastrozole in Tablet Dosage Form

Development and Validation of HPTLC Method for Estimation of Azilsartan Medoxomil in Bulk and Pharmaceutical Dosage Forms

SIMULTANEOUS ESTIMATION OF CILOSTAZOL AND ASPIRIN IN SYNTHETIC MIXTURE USING HPTLC METHOD

Pelagia Research Library

Research Article Available online at

INTERNATIONAL JOURNAL OF RESEARCH IN PHARMACY AND LIFE SCIENCES

Simultaneous Determination of Ramipril, Hydrochlorothizide and Telmisartan by Spectrophotometry

Development and validation of stability indicating reverse phase high performance liquid chromatography method for Timolol Maleate

KEYWORDS: Acetaminophen, Doxylamine succinate, Dextromethorphan hydrobromide.

In the present analytical project, an attempt has been made to develop a simple, economical and reliable liquid

Transcription:

American Journal of Analytical Chemistry, 2012, 3, 704-709 http://dx.doi.org/10.4236/ajac.2012.310093 Published nline ctober 2012 (http://www.scirp.org/journal/ajac) A Stability Indicating UPLC Method for Candesartan in Bulk Drug Samples Gunda Srinivas 1, Kakumani Kishore Kumar 2, Gangaram V. Kanumula 1, M. Vishnu Priya 1, K. Mukkanti 2* 1 CT-2, Dr. Reddy s Laboratories Ltd., Hyderabad, India 2 Centre for Chemical Sciences and Technology, Institute of Sciences and Technology, Jawaharlal ehru Technological University, Hyderabad, India Email: * Kmukkanti@yahoo.co.in Received July 13, 2012; revised August 30, 2012; accepted September 8, 2012 ABSTRACT A simple, sensitive gradient rapid resolution liquid chromatographic assay method has been developed for the quantitative determination of Candesartan Cilexetil in bulk active pharmaceutical ingredient, used for the treatment of hypertension. The developed method is also applicable for the process related impurities determination. Efficient chromatographic separation was achieved on a C18 stationary phase with simple mobile phase combination delivered in a gradient mode and quantification was by ultraviolet detection at 210 nm at a flow rate of 0.4 ml min 1. In the developed UPLC method the resolution between Candesartan Cilexetil and its two potential impurities was found to be greater than 2.0. Regression analysis showed an r value (correlation coefficient) greater than 0.99 for Candesartan Cilexetil and its two impurities. This method was capable to detect two impurities of Candesartan Cilexetil at a level of 0.003% with respect to test concentration of 1.0 mg ml 1 for a 2 μl injection volume. The bulk active pharmaceutical ingredient was subjected to stress conditions of hydrolysis, oxidation, photolysis and thermal degradation. Considerable degradation was found to occur in oxidative stress conditions. The stress samples were assayed against a qualified reference standard and the mass balance was found close to 99.5%. The developed RP-LC method was validated with respect to linearity, accuracy, precision and robustness. Keywords: Column Chromatography; Forced Degradation; Stress Conditions; Candesartan Cilexetil 1. Introduction Candesartan Cilexetil, 2-ethoxy-1-({4-[2-(2H-1,2,3,4-tetrazol-5-yl) phenyl] phenyl} methyl)-1h-1, 3-benzodiazole-6-carboxylic acid is an angiotensin II receptor antagonist used mainly for the treatment of hypertension. Candesartan Cilexetil (Candesartan) is in a class of drugs called angiotensin receptor blockers which includes losartan (Cozaar), valsartan (Diovan), and irbesartan (Avapro). Like these other drugs, candesartan blocks the ability of the chemical angiotensin II to raise the blood pressure by constricting or squeezing arteries and veins. This leads to a reduction in blood pressure. In addition, by reducing the pressure against which the heart must pump blood, candesartan reduces the work of the heart and is useful in patients with heart failure. The effects of angiotensin II also can be blocked by another class of drugs called Angiotensin Converting Enzyme (ACE) inhibitors which prevent the formation of angiotensin II. ACE inhibitors include captopril (Capoten), enalapril (Vasotec), benazepril (Lotensin), and lisinopril (Zestril). * Corresponding author. Candesartan was approved by the FDA in 1998 [1-6]. Few LC methods were reported in the literature for the analysis in biological samples [8]. Extensive literature survey reveals there is no stability indicating UPLC method for determination of related substances and quantitative estimation of Candesartan in bulk drugs and pharmaceutical dosage forms. An ideal stability indicating chromatographic method should estimate the drug to be able to resolve from its potential impurities and degradation products. The present drug stability test guide line Q1A (R2) issued by International Conference on Harmonization (ICH) suggested that stress studies should be carried out on a drug to establish its inherent stability characteristic, leading to separation of degradation products and hence supporting the stability of the proposed analytical procedures. It also requires that analytical test procedures for stability samples should be stability indicating and they should be fully validated [9]. Hence, an attempt has been made to develop an accurate, rapid, specific and reproducible method for the determination of Candesartan and two impurities in bulk

G. SRIIVAS ET AL. 705 drug samples and in pharmaceutical dosage forms along with method validation as per ICH norms. The stability tests were also performed on both drug substances and drug products as per ICH norms. 2. Experimental 2.1. Chemicals Samples of Candesartan and its related impurities were received from Enaltech Labs (Figure 1) LC grade acetonitrile, analytical Trifloro Acetic acid and Triethyl amine were purchased from Merck, Darmstadt, Germany. High purity water was prepared by using Millipore Milli- Q plus water purification system. All samples and impurities used in this study were greater than 99.0%. 2.2. Equipment The UPLC system used for method development, forced degradation studies and method validation was a water Accquity binary pump plus auto sampler and photo diode array detector. The output signal was monitored and processed using Empower software on Pentium computer (Digital Equipment Co.). Photo stability studies were carried out in a photo stability chamber (Sanyo, Leicestershire, UK). Thermal stability studies were performed in a dry air oven (Merck Pharmatech, Mumbai, India). 2.3. Chromatographic Conditions The chromatographic column used was a Zorbax Extended C18 (50 4.6 mm) with 1.8 µm particles. The mobile phase A consists of 0.1% Triethyl amine in water ph 2.2 with TFA and mobile phase B consists of 0.1% TFA in acetonitrile and water in the ratio (95:5). The column temperature was maintained at 40 C and detector was monitored at a wavelength of 210 nm. The injection volume 5 µl. acetonitrile and water was used as a diluent. 3. Precision of Solution 3.1. Precision of Standard Solution A stock solution of Candesartan (2.0 mg ml 1 ) was prepared by dissolving an appropriate amount in diluent. Working solutions were prepared from above stock solution for related substance determination and assay determination, respectively. A stock solution of impurities (mixture of imp-a and imp-b) at a concentration of 0.5 mg ml 1 was also prepared in diluent. 3.2. Specificity Specificity is the ability of the method to measure the analyte response in the presence of its potential impurities. Stress testing of the drug substance can help to identify the likely degradation products, which can in turn help to establish the degradation path ways and the insentric stability of the molecule and validated the stability indicating power of the analytical procedures used. The specificity of the Candesartan in the presence of its impurities namely imp-a and imp-b and degradation products was determined by the developed UPLC method. Forced degradation studies were also performed on Candesartan to provide an indication of the stability indicating property of the proposed method. The stress conditions employed for degradation study including light (carried out as per ICH Q1B), heat (60 C), acid hydrolysis (1 HCl), base hydrolysis (0.1 ah), water hydrolysis (room temperature at 6 h) and oxidation (3% H 2 2 ). For heat light studies the study period was 48 h where as acid, base, peroxide and water hydrolysis the test period was 6 h. Peak purity of stressed samples of Candesartan was checked by using a photo diode array detector of waters corporation, MA, USA. 3.3. Analytical Method Validation The developed chromatographic method was validated for linearity, precision, accuracy, sensitivity, robustness and system suitable. 3.4. Precision The precision of the related substances method was checked by injecting six individual preparations of (500 µg ml 1 ) Candesartan spiked with 0.15% each imp-a CH 3 CH 3 Figure 1. Chemical structure of candesartan. H

706 G. SRIIVAS ET AL. and imp-b. Each % RSD area of imp-a and imp-b was calculated. Precision study was also determined by performing the same procedures on a different day (inter day precision). The intermediate precision (ruggedness) of the method was also evaluated by a different analyst, different column and different instrument in the same laboratory. Assay method precision was evaluated by carrying out six independent assays of test sample of Candesartan against qualified reference standard. The % RSD of six assay values obtained was calculated. The intermediated precision of the assay method was evaluated by different analyst and by using different instrument from the same laboratory. 3.5. Sensitivity Sensitivity was determined by establishing the limit of detection (LD) and limit of quantification (LQ) for imp-a and imp-b estimated at a signal to noise ratio of 3:1 and 10:1 respectively, by injecting a series of dilute solutions with known concentrations. The precision study was also carried out at the LQ level by injecting six individual preparations of imp-a and imp-b and the % RSD for the areas of each impurity was calculated. 3.6. Linearity and Range Linearity test solutions for the assay method has prepared from stock solution at five concentration levels from 50% to 200% of assay analyte concentration (250, 375, 500, 750 and 1000 µg ml 1 ). A linearity test solution for related substance method was prepared by diluting the impurity stock solution to required concentrations. The solutions were prepared at seven concentration levels. From LQ to 200% of the permitted maximum level of the impurity (i.e. LQ 0.0375%, 0.075%, 0.01125%, 0.15%, 0.225% and 0.3%) was subjected to linear regression analysis with the least squares method. Calibration equation obtained from regression analysis was used to calculate the corresponding predicted responses. The residuals and sum of residual squares were calculated from the corresponding predicted responses. Linearity was checked for three consecutive days in the same concentration range for both assay and related substances method and % RSD value of the slope and y- intercept of the calibration curve were calculated. Upper and lower levels of range were also established. 3.7. Accuracy The accuracy of the assay method was evaluated in triplicate at five concentration levels i.e. 250, 375, 500, 750 and 1000 µg ml 1 in bulk drug sample. At each concentration there sets were prepared and injected in triplicate. The percentage of recovery was calculated at each level. The study was carried out in triplicate at 0.075%, 0.125%, 0.15%, 0.225% and 0.3% of the analyte concentration (500 µg ml 1 ). The percentage of recoveries of imp-a and imp-b were calculated. 3.8. Robustness To determine the robustness of the developed method, experimental conditions were deliberately changed and the resolution (Rs) between Candesartan and imp-a and imp-b were evaluated. The flow rate of the mobile phase was 0.4 ml min 1. To study of the effect of flow rate on the developed method 0.1 units of flow were changed (i.e. 0.3 and 0.5 ml min 1 ). The effect of column temperature on the developed method was studied at 35 C and 45 C instead of 40 C. The effect of ph on resolution of impurities was studied by varying ± 0.1 ph units (i.e. buffer ph altered from 2.2 to 2.1 and 2.3). In all the above varied conditions, the components of the mobile phase were held constant. 3.9. Solution Stability and Mobile Phase Stability The solution stability of Candesartan in the assay method was carried out by leaving the test solutions of samples in tightly capped volumetric flasks at room temperature for 48 h. The same sample solutions were assayed at 6 h interval up to the study period against freshly prepared standard solution. The mobile phase stability was also carried out by assaying the freshly prepared sample solution against freshly prepared reference standard solution at 6 h intervals up to 48 h. Mobile phase prepared was kept constant during the study period, The % RSD of assay of Candesartan was calculated for the study period during mobile phase and solution stability experiments. The solution stability of Candesartan and its related impurities was carried out by leaving both spiked and un spiked sample solution in tightly capped volumetric flasks at room temperature for 48 h. Content of imp-a and imp-b were determined at every 6 h interval up to the study period. Mobile phase stability was also carried out for 48 h by injecting the freshly prepared sample solution, for every 6 h interval. Content of imp-a and imp-b was checked in the test solutions. Mobile phase prepared was kept constant during the study period. 4. Results and Discussion 4.1. Method Development and ptimization The main objective of the chromatographic method is to separate Candesartan from imp-a and imp-b were co eluted using different stationary phases such as C 8, Phenyl and cyano as well as different mobile phases. The

G. SRIIVAS ET AL. 707 Chromatographic separation was achieved on a Zorbax Extended C18 (50 4.6 mm) with 1.8 µm column. The peak shape of Candesartan was found to be symmetrical. In optimized chromatographic conditions the peak shape of Candesartan was found to symmetrical and impurities, imp-a and imp-b were separated with a resolution greater than 2, typical retention times were about 0.86, 1.48 and 2.76 min respectively (Figure 2). The system suitability results are given in Table 1 and the developed UPLC method was found to be specific for Candesartan and its two impurities namely imp-a and imp-b (Figure 2). The relative response factors are shown in Figure 3. 4.2. Results of Forced Degradation Degradation was not observed in Candesartan sample when subjected to stress conditions like photolytic, thermal and aqueous hydrolysis. Candesartan was degraded under oxidation, acid and base hydrolysis. Peak purity test results obtained by using PDA detector conformed that the Candesartan peak is homogeneous and pure in the entire analysed stress sample. The assay of Candesartan is unaffected in the presence of Imp-A and imp-b and its degradation products confirm the stability indicating power of the method. The summary of forced degradation studies is given Table 2. Figure 2. Candesartan spike with 0.3% level impurities. Figure 3. RRF solution of impurities and samples. Table 1. System suitability parameters. Parameter Candesartan Imp-A Imp-B Retention Time 2.7 0.8 1.48 Relative Retention Time 1 0.29 0.54 Resolution - 4.8 3.7 Tailing Factor 1 1.04 1.02 Theoretical Plate 4216 6487 10,254

708 G. SRIIVAS ET AL. Table 2. Summary of forced degradation data. Stress Conditions Time (h) Assay of Active Substance (%) Total Impurities Mass Balance (%) (% Assay + % Impurities) ormal 24 99.7% 0.12% 99.8% Acid Hydrolysis 24 99.2% 0.61% 99.8% Base Hydrolysis 24 99.1% 0.85% 100.1% xidation (3% H 2 2 ) 24 80.3% 21.4% 101.7% Water, 70 C 24 99.2% 0.4% 99.6% UV 24 99.3% 0.6% 99.9% 4.3. Precision The % RSD of assay of Candesartan during the assay method precision study was within 0.04% and % RSD for the imp-a and imp-b in related substance method precision study was within 2.5%. The % RSD of the assay results obtained in the intermediate precision study was within 0.09% and the % RSD for the area of imp-a and imp-b were well within 4.06%, conforming good precision of the method. 4.4. Limit of Detection and Limit of Quantification The limit of detection of all the impurities namely imp-a and imp-b was achieved at 0.016% for 5 µl injection volume. The limit of quantification for all impurities namely imp-a and imp-b was achieved at 0.048% for a 5 µl injection volume. The precision at the LQ concentrations for imp-a and imp-b were below 5.2%. 4.5. Linearity The linearity calibration plot for the assay method was obtained over the calibration ranges tested, i.e. 5-60 µg ml 1 and correlation coefficient obtained was 0.999. The result showed that an excellent correlation existed between the peak area and concentration of the analyte. Linear calibration plot for the related substances method was obtained over the calibration ranges tested i.e. LQ (0.05%) to 0.3% for imp-a and imp-b. The correlation coefficient obtained was greater than 0.999. The above results showed that an excellent correlation existed between the peak area and the concentration of imp-a and imp-b. 4.6. Accuracy The percentage recovery of Candesartan in bulk drug samples ranged from 99.8% to 100.3%. The percentage recovery of impurities in Candesartan samples varied from 97.5% to 102.4%. 4.7. Robustness In all the deliberate varied chromatographic conditions (flow rate and column temperature), the resolution between imp-a and imp-b was greater than 4.0, illustrating the robustness of the method. 4.8. Solution Stability and Mobile Phase Stability The % RSD of the assay of Candesartan during solution stability experiments were within 0.5%. o significance changes were observed in the content of impurities namely imp-a and imp-b during the solution stability and mobile phase stability experiments when performed using the related substance method. The solution stability and mobile phase stability experiment data confirmed that the sample solutions and mobile phases used during the assay and related substance determination were stable for at least 48 h. 5. Conclusion The UPLC method developed for quantitative and related substances determination of Candesartan is precise, accurate, rapid and specific. The method was fully validated, and the data found to be satisfactory for all the method validation parameters tested. The developed method is stability indicating and can be conveniently used by a quality control department to determine the related substance and assay of regular Candesartan commercial samples and also stability samples. 6. Acknowledgements The author would like to thank the management of Dr. Reddy s laboratories, Hyderabad, India for their support to carry out this investigation. REFERECES [1] E. evin, Simultaneous Analysis of Candesartan Cilexetil and Hydrochlorothiazide in Human Plasma and Dosage Forms Using HPLC with a Photodiode Array Detector, Journal of Liquid Chromatography & Related Technologies, Vol. 26, o. 15, 2003, pp. 2581-2591. doi:10.1081/jlc-120023802 [2] C. Fenton and L. J. Scott, A Review of Its Use in the

G. SRIIVAS ET AL. 709 Management of Chronic Heart Failure, Drugs, Vol. 65, o. 4, 2005, pp. 537-558. doi:10.2165/00003495-200565040-00007 [3] R. Revathi, T. Ethiraj, J. L. Marreddy and V. Ganeshan, Development and Validation of a Dissolution Test for Candesartan Cilexetil in Tablet Forms Using Reverse Phase High Performance Liquid Chromatography, Journal of Pharmaceutical Education and Research, Vol. 2, o. 2, 2011, pp. 71-77. [4] M. M. Annapurnaa, A. arendra and K. R. Kumar, Liquid Chrmotographic Method for Determination of Candesartan Cilexetil and Hydrochlorothiazide in Pharmaceutical Dosage Forms, Journal of Drug Delivery & Therapeutics, Vol. 2, o. 2, 2012, pp. 48-54. [5] K. B. Tejaswini, K. M. Shrinivas and S. M. Chandrakant, Simultaneous Estimation of Candesartan Cilexetil and Hydrochlorothiazide in Tablet Dosage Form by UV Spectrophotometric Method, International Journal of Pharmtech Research, Vol. 4, o. 2, 2012, pp. 786-790. [6] S. T. Prajapati, P. K. Patel, M. Patel, V. B. Chauhan and C.. Patel, Development and Validation of the Liquid Chromatography-Tandem Mass Spectrometry Method for Quantitative Estimation of Candesartan from Human Plasma, Pharmaceutical Methods, Vol. 2, o. 2, 2011, pp. 130-134. [7] B. H. Mehta and S. B. Morge, HPTLC-Densitometric Analysis of Candesartan Cilexetil and Hydrochlorothiazide in Tablets, Journal of Planar Chromatography, Modern TLC, Vol. 21, o. 2, 2008, pp. 173-176. doi:10.1556/jpc.21.2008.3.3 [8] Y. D. Zhang, X. H. Wei, A. F. Wang, Y. J. Xu, X. H. Zhu and J. M. Luo, HPLC Determination of Candesartan Cilexetil and Its Related Substances, Central South Pharmacy, Vol. 2, o. 2, 2004, pp. 80-83. [9]. Devanaboyina and T. Satyanarayana, Simultaneous Determination of Candesartan and Hydrochlorothiazide in Combined Pharmaceutical Dosage Form by ew RP- HPLC Method, Research Journal of Pharmaceutical, Biological and Chemical, Sciences, Vol. 3, o. 1, 2012, pp. 270-278.