LAPBIAT ATMOSPHERIC SOUNDING CAMPAIGN IN 2010: UPPER AIR AND REMOTE SENSING OBSERVATIONS OF WATER VAPOR

Similar documents
SATELLITE DATA VALIDATION IN SODANKYLÄ, NORTHERN FINLAND; EPS VALIDATION CAMPAIGN IN 2007

WG 1 workshop on the LAPBIAT Atmospheric Sounding campaign at the Finnish Meteorological Institute in Helsinki, September 2-3, 2010.

Field experiments at Sodankylä

Pallas-Sodankylä GAW site (global)

The Vaisala Reference Radiosonde Program: First Results and Future Plans

Fluorescence Lyman-Alpha Stratospheric Hygrometer for Balloon (FLASH-B)

OBSERVATIONS OF WATER VAPOUR ON BOARD LONG-DURATION SUPER PRESSURE BALLOON USING FLASH-B LYMAN-ALPHA HYGROMETER

13B.2 COMPARISON OF SELECTED IN-SITU AND REMOTE SENSING TECHNOLOGIES FOR ATMOSPHERIC HUMIDITY MEASUREMENT

The GRUAN Observing Station Payerne - Switzerland

LUAMI CAMPAIGN FALL 2008 SUMMARY

The GRUAN Observing Station Payerne - Switzerland

INTRODUCTION OPERATIONS

Specifications for a Reference Radiosonde for the GCOS Reference. Upper-Air Network (GRUAN)

Research Activities at Sodankylä

COBALD measurements of aerosol backscatter in the ASM: , and outlook on the StratoClim WP2 field campaign (2016)

A NOVEL RADIOSONDE PAYLOAD TO STUDY UPPER TROPOSPHERIC / LOWER STRATOSPHERIC AEROSOL AND CLOUDS

Accuracy of tropospheric and stratospheric water vapor measurements by the cryogenic frost point hygrometer: Instrumental details and observations

Report of CoreTemp2017: Intercomparison of dual thermistor radiosonde (DTR) with RS41, RS92 and DFM09 radiosondes

x = x a +(K T S e -1 K+S a -1 ) -1 K T S e -1 *[R-F(x)+K*(x-x a )]

Retrieval of tropospheric water vapour by using spectra from a microwave spectro-radiometer at 22 GHz

Site Report: Lauder, New Zealand

New Peltier-based chilled-mirror hygrometer SKYDEW

GRUAN Data Flow and RS92 Data Product v2

AirCore flights at Sodankylä Rigel Kivi, Pauli Heikkinen, Juha Hatakka, Tuomas Laurila, Leif Backman, Jouni Pulliainen (1), Huilin Chen (2, 3)

GRUAN Site Report for La Réunion

MEASUREMENTS AND MODELLING OF WATER VAPOUR SPECTROSCOPY IN TROPICAL AND SUB-ARCTIC ATMOSPHERES.

UPPER TROPOSPHERIC WATER VAPOUR AND ITS INTERACTION WITH CIRRUS CLOUDS

FTS measurements of greenhouse gases over Sodankylä, Finland

GRUAN Station Report for Ny-Ålesund

Pathway from the boundary layer to the UTLS

Results from WMO High Quality Radiosonde Comparison, Mauritius As related to planning Reference Upper Air Observations for GCOS

Comparison of AMSU-B Brightness Temperature with Simulated Brightness Temperature using Global Radiosonde Data

Influence of the polar vortex on Arctic column-averaged dry-air mixing ratios of atmospheric methane

Title. Author(s) 杉立, 卓治. Issue Date DOI. Doc URL. Type. File Information /doctoral.k

Validation of water vapour profiles from GPS radio occultations in the Arctic

Lidar and radiosonde measurement campaign for the validation of ENVISAT atmospheric products

Climate & Earth System Science. Introduction to Meteorology & Climate. Chapter 05 SOME OBSERVING INSTRUMENTS. Instrument Enclosure.

Observations of Integrated Water Vapor and Cloud Liquid Water at SHEBA. James Liljegren

The Meisei sonde data product

Transition from VIZ/Sippican to ROTRONIC

Observations at Sodankylä

EUMETSAT STATUS AND PLANS

PRESENTATIONS ON RECENT NATIONAL TESTS/COMPARISONS. Recent Tests and Comparisons of Radiosonde Operated by Japan Meteorological Agency

VALIDATION OF MIPAS WATER VAPOR PRODUCTS BY GROUND BASED MEASUREMENTS

Title. Author(s)Inai, Y.; Shibata, T.; Fujiwara, M.; Hasebe, F.; Vöm. CitationGeophysical Research Letters, 39(20): L Issue Date

NIWA s Lauder Site 45.0 S, E 370m a.s.l.

UPDATE on: Consistency for water vapour of GRUAN, LBLRTM and IASI

Validation of Water Vapour Profiles from GPS Radio Occultations in the Arctic

Change management for the RS92 phase out

GRUAN Site Report for Ny-Ålesund

The AQUAVIT formal intercomparison of atmospheric water measurement methods

Towards SI traceable humidity measurements with radiosondes

Sudden stratospheric warming and O3 depletion

GROUNDBASED FTIR, OZONESONDE AND LIDAR MEASUREMENTS FOR THE VALIDATION OF SCIAMACHY (AOID 331)

Clear-Air Forward Microwave and Millimeterwave Radiative Transfer Models for Arctic Conditions

NASA/GSFC Raman Lidar Instrumentation Available for COPS

Retrieval of tropospheric and middle atmospheric water vapour profiles from ground based microwave radiometry

Abstract. Introduction

IASI Level 2 Product Processing

microwave profiler: comparisons and synergies

Ny-Ålesund: Site Update & Atmosphere Flagship Program. Marion Maturilli, Sandro Dahlke, Roland Neuber, Andrea Merlone

Retrieval of upper tropospheric humidity from AMSU data. Viju Oommen John, Stefan Buehler, and Mashrab Kuvatov

Direct effects of particle precipitation and ion chemistry in the middle atmosphere

First water vapor measurements over Athens, Greece, obtained by a combined Raman-elastic backscatter lidar system

GRUAN and Satellite Collocation Xavier Calbet - EUMETSAT

Overview and quality of global observations of middle atmospheric water vapour by the Odin satellite

Status of GRUAN certification for French sites

Performance of the Meteolabor Snow White chilled-mirror hygrometer. Masatomo Fujiwara Hokkaido University, Japan

Aura Microwave Limb Sounder (MLS) ozone profile data record characteristics, quality and applications

Humidity sensor failure: a problem that should not be neglected. by the numerical weather prediction community

Deutscher Wetterdienst

2.5 COMPARING WATER VAPOR VERTICAL PROFILES USING CNR-IMAA RAMAN LIDAR AND CLOUDNET DATA

The AQUAVIT formal intercomparison of atmospheric water measurement methods

First water vapor measurements over Athens, Greece, obtained by a combined Raman-elastic backscatter lidar system.

J2.11 PROPERTIES OF WATER-ONLY, MIXED-PHASE, AND ICE-ONLY CLOUDS OVER THE SOUTH POLE: PRELIMINARY RESULTS

CORRELATION BETWEEN ATMOSPHERIC COMPOSITION AND VERTICAL STRUCTURE AS MEASURED BY THREE GENERATIONS OF HYPERSPECTRAL SOUNDERS IN SPACE

Aircraft and satellite hyperspectral measurements investigating the radiative impact of atmospheric water vapour

The Meteorological Observatory from Neumayer Gert König-Langlo, Bernd Loose Alfred-Wegener-Institut, Bremerhaven, Germany

Reference quality upper-air measurements: GRUAN data processing for the Vaisala RS92 radiosonde

F O U N D A T I O N A L C O U R S E

Water vapour above Switzerland over the last 12 years

Recent Application of The Accurate Temperature Measuring (ATM) Radiosonde

Atmosphere-Space Interactions Monitor (ASIM) on the International Space Station

APPENDIX 2 OVERVIEW OF THE GLOBAL PRECIPITATION MEASUREMENT (GPM) AND THE TROPICAL RAINFALL MEASURING MISSION (TRMM) 2-1

Polar vortex dynamics observed by means of stratospheric and mesospheric CO ground-based measurements carried out at Thule (76.5 N, 68.

CMA Consideration on early-morning orbit satellite

Lecture 14. Principles of active remote sensing: Lidars. Lidar sensing of gases, aerosols, and clouds.

A new lidar for water vapor and temperature measurements in the Atmospheric Boundary Layer

Validation of the Harvard Lyman- α in situ water vapor instrument: Implications for the mechanisms that control...

1. The frequency of an electromagnetic wave is proportional to its wavelength. a. directly *b. inversely

SIMULATION OF SPACEBORNE MICROWAVE RADIOMETER MEASUREMENTS OF SNOW COVER FROM IN-SITU DATA AND EMISSION MODELS

Use of FY-3C/GNOS Data for Assessing the on-orbit Performance of Microwave Sounding Instruments

Future cm & mm Wavelength Occultation System: Active Temperature, Ozone and Moisture Microwave Spectrometer (ATOMMS) E. R.

Atmospheric Lidar The Atmospheric Lidar (ATLID) is a high-spectral resolution lidar and will be the first of its type to be flown in space.

Deutscher Wetterdienst sites around Germany

Overview of Met Office Intercomparison of Vaisala RS92 and RS41 Radiosondes

Many short reports are inadequate and need more work

ADVANCED ATMOSPHERIC BOUNDARY LAYER TEMPERATURE PROFILING WITH MTP-5HE MICROWAVE SYSTEM

LAUNCH Concept. Lindenberg Observatory

Passive microwave observations

Transcription:

LAPBIAT ATMOSPHERIC SOUNDING CAMPAIGN IN 2010: UPPER AIR AND REMOTE SENSING OBSERVATIONS OF WATER VAPOR Rigel Kivi (1), Holger Vömel (2), Franz Immler (2), Terhi Lehtola (3), Niklaus Kämpfer (4), Corinne Straub (4), Vladimir Yushkov (5), Sergey Khaykin (5), Tina Christensen (6), Frank G. Wienhold (7) (1) Arctic Research, Finnish Meteorological Institute, Sodankylä, Finland, (2) Meteorological Observatory Lindenberg / Richard Aßmann Observatory, German Meteorological Service (DWD), Lindenberg, Germany, (3) Vaisala Oy, Helsinki, Finland, (4) Institute of Applied Physics, University of Bern, Bern, Switzerland, (5) Central Aerological Observatory, Russian Federal Service for Hydrometeorology and Monitoring of the Environment (Roshydromet), Dolgoprudny, Russian Federation, (6) Danish Climate Centre, Danish Meteorological Institute, Copenhagen, Denmark, (7) Institute for Atmospheric and Climate Science, Swiss Federal Institute of Technology, Zürich, Switzerland ABSTRACT Accurate measurements of water vapor in the upper troposphere and lower stratosphere (UTLS) are needed for the climate studies. In January-June 2010 the LAPBIAT atmospheric sounding campaign took place in Sodankylä, northern Finland (67.4º N, 26.6º E) to perform profile measurements of water vapor and aerosols in the troposphere and stratosphere by different in situ and remote sensing instruments. The campaign involved balloon borne research grade water vapor instruments such as the Cryogenic Frostpoint Hygrometer (CFH) and the Lyman- alpha fluorescence hygrometer FLASH-B. The climate research radiosonde Vaisala RR01, which is currently under development, was flown in the same payload with the cryogenic frost point hygrometer and the fluorescence hygrometer. The remote sensing instruments participating in the campaign included the microwave radiometer for water vapor measurements MIAWARA-C. This instrument was operated for a six month period, until mid-june 2010. The aerosol in situ profile measurements were made by the new COBALD instrument and by a well established balloon borne aerosol backscatter sonde. The particle measurements in the stratosphere were made simultaneously with the water vapor measurements. Here we provide an overview of the LAPBIAT campaign activities in Sodankylä, including the upper air and remote sensing instrument descriptions and first results of the measurements of water vapor and stratospheric aerosols in the Arctic vortex in early 2010. Campaign site Sodankylä site (67.4 N, 26.6 E, 179 m above mean sea level) is operated by the Finnish Meteorological Institute Arctic Research Centre. The site is representative of high latitude conditions in the northern Europe. During winter and spring the upper air soundings are frequently sampling air inside the stratospheric vortex. Several measurement programs are running on the long term basis, for example Sodankylä has one of the longest records of upper air measurements of temperature and ozone in the European sector of Arctic. The site has also been active in 1

instrument comparison (e.g. LAUTLOS-WAVVAP in 2004 (Deuber et al., 2005; Vömel et al., 2007; Suortti et al., 2008)) and satellite (e.g. ENVISAT, Aura, MetOp) validation campaigns. Sodankylä is also among the initial stations of the GRUAN network. The Global Climate Observing System (GCOS) Reference Upper Air Network (GRUAN) was established in year 2008 to meet climate requirements and to improve the current global observing system (Seidel et al., 2009). Upper air observations within the network are expected to provide long-term high-quality climate records, they will be used to validate space based sensors, and will provide data for the study of atmospheric processes. LAPBIAT Atmospheric Sounding Campaign The campaign took place in Sodankylä from mid-january 2010 until mid-june 2010. The balloon soundings were made during two time periods. First from January 17 until February 6 altogether 18 balloon payloads were launched with different combination of in situ instruments, total number of sensors flown was 119. In January 2010 very low temperatures were measured in the polar vortex, during this time a series of water vapor and aerosol sonde flights were performed under night-time conditions. From March 10 to March 24 altogether 15 sonde payloads were launched, mostly under day-time conditions, in total 53 different sensors were flown. The campaign included research grade light-weight balloon borne water vapor instruments such as FLASH-B (Lyman- alpha fluorescence hygrometer) and the Cryogenic Frostpoint Hygrometer (CFH). The prototype of the operational reference radiosonde Vaisala RR01 was flown in the same payload with the cryogenic frost point hygrometer and the fluorescence hygrometer (Lehtola et al., 2010). The radiosondes included RS92 and RS80 by Vaisala, and radiosondes developed by Intermet and Graw. Ozone profiles were measured by ECC type ozone sensors. The Cryogenic Frost-point Hygrometer (CFH) is a research grade instrument of atmospheric humidity measurements up to the altitude of 25-28 km (Vömel et al., 2007). The instrument measures temperature of a mirror, which maintains a small and constant layer of frost coverage. The cryogenic cooling of the mirror ensures that the frost-point temperatures are achieved even in the coldest and driest layers. Relative humidity and mixing ratio can be calculated based on the frost-point temperature measurement. CFH is a relatively new instrument, some of the first flights of the CFH instrument were made in Sodankylä during the LAUTLOS campaign (Vömel et al., 2007). During the LAPBIAT campaign the CFH instrument was flown with Vaisala RS80 sondes (5 flights) and with Intermet radiosondes (14 flights), 13 CFH flights were combined with the COBALD backscatter sonde and all 19 CFH payloads had an ECC ozone sensor included. The FLuorescence Advanced Stratospheric Hygrometer for Balloon (FLASH-B) instrument is the Lyman-alpha hygrometer developed at the Central Aerological Observatory. The instrument is based on the fluorescent method, which uses the photodissociation of H2O molecules at a wavelength <137 nm followed by the measurement of the fluorescence of excited OH radicals. The source of Lyman-alpha radiation (at 121.6 nm) is a hydrogen discharge lamp. The detector of OH fluorescence at 308 316 nm is a Hamamatsu R647-P photomultiplier. The intensity of the fluorescent light sensed by the photomultiplier is directly proportional to the water vapor mixing ratio under stratospheric conditions (10 150 hpa) with small oxygen absorption (3% at 50 hpa). The H2O measurement range is limited to pressures lower than 300 400 hpa due to strong 2

Lyman-alpha absorption in the lower troposphere. In Sodankylä during the campaign the instrument was interfaced to the Vaisala RS92 radiosonde. In total 12 flight of FLASH-B instrument were made during the campaign, 4 flights involved the new experimental version of the instrument. RS92 radiosonde humidity sensor is a thin-film capacitor that directly measures relative humidity. It consists of two sensors, which are alternately measuring and being heated, thus eliminating coating of the sensor by ice or liquid inside clouds. The RS92 sonde has been manufactured since 2004 and the development of the sensor has been documented by Vaisala (2010). One of the important improvements was the new coating of humidity sensor contacts in late 2006 (Vaisala 2010). In total 47 RS92 sensors were flown during the LAPBIAT campaign. RR01 is the prototype of the operational reference radiosonde (Lehtola et al., 2010; Vaisala, 2010). The RR01 sonde consists of RS92 radiosonde and Vaisala DRYCAP sensor. The latter is a new capacitive sensor capable of measuring very low humidity values in upper troposphere and lower stratosphere. During the LAPBIAT campaign we performed 21 RR01 measurements, combined with the CFH frost point hygrometer observations, the results are reported by Lehtola et al. (2010). Tropospheric water vapor profiles measured by different instruments on January 20 at 15:25 UT are shown as an example of the water vapor sensor comparison flights (Figure 1). This represents a night-time sounding under typical high relative humidity conditions in the lower troposphere, very dry layers in the middle troposphere and cirrus clouds in the higher troposphere. Good agreement between RS92 and CFH humidity measurements can be seen, while the Intermet sonde humidity sensor seems to show larger differences relative to the CFH. Two separate RS92 sensors were flown in this payload showing almost identical humidity readings. Aerosol profile measurements were made by a well established aerosol backscatter sonde (Rosen and Kjome, 1991) and by the newly developed light-weight aerosol backscatter sonde COBALD (Compact Optical Backscatter Aerosol Detector). The COBALD instrument is a lightweight backscatter sonde designed by Institute for Atmospheric and Climate Science of the Swiss Federal Institute of Technology Zürich. The instrument uses two high power LEDs in the blue and near infrared spectral range (455 nm and 870 nm) and detects the backscattered light from air molecules, aerosol or cloud droplets. This allows retrieving information of aerosol (or cloud) particle size and number density. In the LAPBIAT campaign configuration it was flown together with an Intermet radiosonde and CFH water vapor sonde. During the campaign 11 COBALD sonde flights were performed in January-Febraury and two flights in March 2010. The backscatter sonde (BKS), constructed at the University of Wyoming (Rosen and Kjome, 1991), is equipped with a xenon flash lamp, giving a light pulse about once every 7 s. The backscattered light from aerosol and cloud particles is detected by photodiodes on the sonde, each equipped with filters transmitting in two wavelengths around 490 nm and 940 nm. The sonde detects the backscattered signal, at an angle about 173º with respect to the beam forward direction, from an air volume of approximately 1m3 within a few meters from the instrument. Backscatter ratio, i.e. the ratio between the total (particulate and molecular) to the molecular volume backscattering coefficients is the basic measurement of the sonde. During LAPBIAT one of the goals was to 3

perform COBALD versus backscatter sonde comparison flights. These comparison flights were made in January 23 and 24 in the presence of polar stratospheric clouds (PSCs). Figure 1. Tropospheric humidity measurements on 20 January 2010 at 15:25 UT over Sodankylä, Finland, using the CFH cryogenic frost point hygrometer, two Vaisala RS92 sensors (marked as sensor a and b ) and the Intermet radiosonde. 4

Figure 2 presents COBALD measurement of very strong PSC layers on January 17, 2010 together with the stratospheric water vapor measurements by two sensors: FLASH-B and CFH. Both sensors show decrease in water vapor mixing ratio above 22 km of altitude. This reduction of water vapor can be attributed to the formation of ice PSCs. Indeed, ice PSC particles were detected in the layer of 22-24 km by COBALD and BKS sondes. Sodankyla 67.4 N 17 January 2010 21 UT FLASH-B, RS92, Cobald, CFH (ascent) 24 Temperature, deg. C -90-80 -70-60 100 RHi, % 120 140 160 22 20 Height, km 18 16 14 BKS ratio at 870 nm water vapour temperature RHi saturation mix. ratio water vapour (CFH) 12 WVMR, ppmv 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 2 3 4 5 6 7 8 9 100 BKS ratio Figure 2. Stratospheric humidity measurements on 17 January 2010 over Sodankylä, Finland, using a CFH cryogenic frost point hygrometer and a FLASH-B hygrometer. Aerosol backscatter ratio at 870 nm was measured by COBALD and temperature profile by Vaisala RS92 radiosonde. The sequence of stratospheric water vapor measurements by FLASH-B and CFH hygrometers is shown in Figure 3. The extremely low temperatures in the Arctic vortex led to the formation of PSC and thus formation of dehydrated layers in the stratosphere. In the dehydrated layer at 20-24 km water vapor reduction of up to 1.2 ppmv was observed and a rehydration layer below at 18-21 with water vapor enhancements up to 1.1 ppmv. Ice particle sedimentation of about 2 km led to redistribution of stratospheric water vapor within 18-24 km layer in the lower stratosphere. 5

28 26 24 FLASH-B /RS92 CFH / Intermet LAPBIAT-2010 Sodankyla 67.4 N, 26.6 E Temperature, deg. C -90-80 -70-60 -50 Height, km 22 20 18 16 17 Jan 2010 22 Jan 2010 23 Jan 2010 25 Jan 2010 28 Jan 2010 29 Jan 2010 14 12 10 2 3 4 5 6 7 8 9 10 water vapour, ppmv Figure 3. Stratospheric water vapor measurements from 17 to 29 January 2010 over Sodankylä, Finland, using the CFH cryogenic frost point hygrometers and the FLASH-B hygrometers. The corresponding temperature profiles are also shown (right panel). Comparison of the sonde water vapor measurements with the spaceborne observations from the Microwave Limb Sounder (MLS) on board the Aura satellite are shown in Figure 4: January 21 and January 28 individual profiles and average difference between the measurements. The two cases were chosen to represent the days, when the CFH sonde sampled the dehydrated and rehydrated water vapor layers in the Arctic vortex. The ground based remote sensing instruments participating in the campaign included the new microwave radiometer for water vapor measurements MIAWARA-C developed by the University of Bern (Straub et al., 2010). MIAWARA-C is a 22GHz water vapor spectro-radiometer which has been designed for profile measurement campaigns of the middle atmosphere. The instrument can be operated as a standalone instrument. The optical system combines a choked gaussian horn antenna with a parabolic mirror, which reduces the size of the instrument. Calibration is done 6

through a balancing scheme with the sky used as the cold load and the tropospheric properties are determined by performing regular tipping curves. The instrument was operated in Sodankylä from January to June 2010 and the first results are reported by Straub et al. (2010). Figure 4. Left: Water vapor measurements by Cryogenic Frost point Hygrometer (CFH, black dots) and Aura MLS instrument (red dots) on January 21 and 28, 2010. The grey dots in the background represent the high vertical resolution data measured by the CFH instrument. Right: average relative difference for all January-February 2010 comparisons. References Deuber, B., A. Haefele, D. G. Feist, L. Martin, N. Kampfer, G. E. Nedoluha, V. Yushkov, S. Khaykin, R. Kivi, and H. Vömel (2005), Middle Atmospheric Water Vapor Radiometer (MIAWARA): Validation and first results of the LAPBIAT Upper Tropospheric Lower Stratospheric Water Vapor Validation Project (LAUTLOS-WAVVAP) campaign, J. Geophys. Res., 110, D13306, doi:10.1029/2004jd005543. Karpechko, A.; Lukyanov, A.; Kyro, E.; Khaikin, S.; Korshunov, L.; Kivi, R.; Vömel, H. (2007), The water vapor distribution in the Arctic lowermost stratosphere during LAUTLOS campaign and related transport processes including stratosphere-troposphere exchange. Atmospheric Chemistry and Physics, 7, 107-119. Kivi, R., Kujanpää, J., Aulamo, O., Heikkinen, P., Hassinen, S., Calbet, X., Montagner, F., Vömel, H., Observations of water vapor profiles over Northern Finland by satellite and balloon borne instruments (2009), EUMETSAT Meteorological Satellite Conference, 21-25 September 2009, Bath, UK, EUMETSAT P.55. 7

Lehtola, T., P. Survo, H. Turtiainen, R. Kivi (2010), Application of Vaisala Drycap Sensor in Upper Troposphere and Lower Stratosphere Humidity Measurements, Upper-Air and Remote Sensing Observations of Water Vapor. WMO Technical Conference on Meteorological and Environmental Instruments and Methods of Observation (TECO-2010), Helsinki, Finland, 30 August - 1 September 2010. Rosen, J. M. and Kjome, N. T. (1991), Backscattersonde - A new instrument for atmospheric aerosol research, Appl. Optics, 30, 1552 1561. Seidel, D. et al. (2009), Reference Upper-Air Observations for Climate: Rationale, Progress, and Plans, Bulletin of the American Meteorological Society, March 2009. Straub, C., A. Murk, and N. Kaempfer (2010), MIAWARA-C, a new ground based water vapor radiometer for measurement campaigns, Atmos. Meas. Tech. Discuss., 3, 2389-2432, doi:10.5194/amtd-3-2389-2010. Suortti, T.M., A. Kats, R. Kivi, N. Kämpfer, U. Leiterer, L.M. Miloshevich, R. Neuber, A. Paukkunen, P. Ruppert, H. Vömel, and V. Yushkov (2008), Tropospheric Comparisons of Vaisala Radiosondes and Balloon-Borne Frost-Point and Lyman-α Hygrometers during the LAUTLOS-WAVVAP Experiment. J. Atmos. Oceanic Technol., 25, 149-166. Vaisala (2010), Data continuity (available at http://www.vaisala.com/weather/products/datacontinuity.html). Vaisala (2010), Reference radiosonde program (available at http://www.vaisala.com/weather/applications/referenceradiosondeprogram.html). Vömel, H., D. E. David, and K. Smith (2007), Accuracy of tropospheric and stratospheric water vapor measurements by the cryogenic frost point hygrometer: Instrumental details and observations, J. Geophys. Res., 112, D08305, doi:10.1029/2006jd007224. Vömel, H., H. Selkirk, L. Miloshevich, J. Valverde-Canossa, J. Valdés, E. Kyrö, R. Kivi, W. Stolz, G. Peng, and J.A. Diaz (2007), Radiation Dry Bias of the Vaisala RS92 Humidity Sensor. J. Atmos. Oceanic Technol., 24, 953 963. Vömel, H., V. Yushkov, S. Khaykin, L. Korshunov, E. Kyrö, R. Kivi (2007), Intercomparisons of Stratospheric Water Vapor Sensors: FLASH-B and NOAA/CMDL Frost-Point Hygrometer. J. Atmos. Oceanic Technol., 24, 941 952. Yushkov, V., Merkulov, S., and Astakhov, V. (1998), Optical balloon hygrometer for upper stratosphere and stratosphere water vapor measurements, in: Optical remote sensing of the atmosphere and clouds, edited by: Wang, J., Wu, B., Ogawa, T., and Guans, Z.-H.: Proc. SPIE, 3501, 439 445. 8