PoS(TIPP2014)093. Performance study of the TOP counter with the 2 GeV/c positron beam at LEPS. K. Matsuoka, For the Belle II PID group

Similar documents
Performance of the MCP-PMT for the Belle II TOP counter

Construction of the Belle II TOP counter

PoS(PD07)020. Timing Properties of MCP-PMT. Kenji Inami. Nagoya university, Nagoya, Japan

Tests of the Burle anode MCP PMT as a detector of Cherenkov photons

arxiv: v1 [physics.ins-det] 3 Dec 2018 Fast Interaction Trigger for the upgrade of the ALICE experiment at CERN: design and performance

Time of Flight measurements with MCP-PMT

PoS(TIPP2014)033. Upgrade of MEG Liquid Xenon Calorimeter. Ryu SAWADA. ICEPP, the University of Tokyo

Particle Identification at a super B Factory. FRASCATI WORKSHOP DISCUSSION ON PID

Tests of the BURLE 64-anode MCP PMT as the detector of Cherenkov photons

Tests of the BURLE 64-anode MCP PMT as the detector of Cherenkov photons

Time-of-Flight PET using Cherenkov Photons Produced in PbF 2

Kaon Identification at NA62. Institute of Physics Particle, Astroparticle, and Nuclear Physics groups Conference 2015

The Fast Interaction Trigger Upgrade for ALICE

Aerogel RICH counter for the Belle II forward PID

Validation of Geant4 Physics Models Using Collision Data from the LHC

PoS(KAON09)023. Beam Hole Photon Veto For J-PARC K O TO experiment. Yosuke Maeda Kyoto University

The Barrel DIRC Detector for the PANDA Experiment at FAIR

RICH detectors for LHCb

PoS(DIS 2010)058. ATLAS Forward Detectors. Andrew Brandt University of Texas, Arlington

A RICH Photon Detector Module with G-APDs

Module of Silicon Photomultipliers as a single photon detector of Cherenkov photons

Hands on Project: Large Photocathode PMT Characterization

Particle production vs. energy: how do simulation results match experimental measurements?

PoS(PD07)031. General performance of the IceCube detector and the calibration results

The TORCH project. a proposed detector for precision time-of-flight over large areas. Roger Forty (CERN)

Development of Ring-Imaging Cherenkov Counter for Heavy Ions

Cherenkov Detectors in Particle Physics. Brad Wogsland University of Tennessee

arxiv:hep-ex/ v1 22 Apr 2002

Status of the LHCb RICH and hadron particle identification

Timing and cross-talk properties of BURLE multi-channel MCP-PMTs

Geant4 simulations of the lead fluoride calorimeter

arxiv: v1 [physics.ins-det] 22 Dec 2013

PoS(PhotoDet 2012)008

The HERMES Dual-Radiator Ring Imaging Cerenkov Detector N.Akopov et al., Nucl. Instrum. Meth. A479 (2002) 511

PoS(ICRC2015)641. Cloud Monitoring using Nitrogen Laser for LHAASO Experiment. Z.D. Sun 1,Y. Zhang 2,F.R. Zhu 1 for the LHAASO Collaboration

THE FORWARD DETECTOR OF THE ANKE SPECTROMETER. SCINTILLATION AND CHERENKOV HODOSCOPES

PoS(EPS-HEP2015)522. The status of MICE Step IV

7. Particle identification

Concepts of Event Reconstruction

PoS(KAON)059. Giuseppe Ruggiero. Scuola Normale Superiore and INFN, Pisa, Italy

A gas-filled calorimeter for high intensity beam environments

Determination of parameters of cascade showers in the water calorimeter using 3D-distribution of Cherenkov light

First Stage Analysis of the Energy Response and Resolution of the Scintillator ECAL in the Beam Test at FNAL, 2008

Emittance Measurement in the Muon Ionization Cooling Experiment

Guest Lecture PHY 7361: Harnessing Cherenkov Radiation SteveSekula, 13 April 2010 (created 9 April 2010)

PoS(KAON)049. Testing the µ e universality with K ± l ± ν decays

New Hadroproduction results from the HARP/PS214 experiment at CERN PS

Theory English (Official)

THE AMS RICH COUNTER

Particle Identification with Disc DIRC at PANDA

Calorimetry in particle physics experiments

ARTICLE IN PRESS. Nuclear Instruments and Methods in Physics Research A

Muon reconstruction performance in ATLAS at Run-2

Investigation of nuclear Equation of State (EoS) is an attractive subject not only for nuclear

PoS(HCP2009)042. Status of the ALICE Experiment. Werner Riegler. For the ALICE Collaboration. CERN

GEANT4 simulation of the testbeam set-up for the ALFA detector

arxiv: v1 [physics.ins-det] 15 Oct 2018

PoS(HEP2005)177. Status of the OPERA experiment. Francesco Di Capua. Universita Federico II and INFN.

Timing calibration of the LHAASO-KM2A electromagnetic particle detectors

TORCH: A large-area detector for precision time-of-flight measurements at LHCb

The NA62 RICH detector

NA62: Ultra-Rare Kaon Decays

PANDA Muon System Prototype

The Factors That Limit Time Resolution for Photon Detection in Large Cherenkov Detectors

PoS(HIGH-pTLHC)022. The VHMPID detector in the ALICE experiment at LHC. Giacomo Volpe. INFN Bari, Italy

Picosecond Time-of-Flight Measurement for Colliders Using Cherenkov Light

A Start-Timing Detector for the Collider Experiment PHENIX at RHIC-BNL

hadronic decays at BESIII Abstract hadronic decays using a double tag technique. Among measurement for twelve Λ c

Calibration and Performance of the ATLAS Tile Calorimeter During the LHC Run 2

Status of the LHCb RICH detector and the HPD

PoS(KAON13)012. R K Measurement with NA62 at CERN SPS. Giuseppe Ruggiero. CERN

Simulation study of scintillatorbased

Dual readout with tiles for calorimetry.

What detectors measure

Lecture 16 Light transmission and optical detectors

THE LHCb experiment [1] is a forward spectrometer

First Stage Analysis of the Energy response and resolution of the Scintillator ECAL in the Beam Test at FNAL, 2008

Thin Calorimetry for Cosmic-Ray Studies Outside the Earth s Atmosphere. 1 Introduction

Simulation and validation of the ATLAS Tile Calorimeter response

Results from R&D of Cherenkov detectors at Novosibirsk

A method to measure transit time spread of photomultiplier tubes with Cherenkov light

Particle Detectors A brief introduction with emphasis on high energy physics applications

STATUS OF ATLAS TILE CALORIMETER AND STUDY OF MUON INTERACTIONS. 1 Brief Description of the ATLAS Tile Calorimeter

CALICE Si-W EM Calorimeter: Preliminary Results of the Testbeams 2006

Study of high muon multiplicity cosmic-ray events with ALICE at the CERN Large Hadron Collider

V0 cross-section measurement at LHCb. RIVET analysis module for Z boson decay to di-electron

Particle Identification of the LHCb detector

Development of Secondary Electron Time Detector for Ion Beams

The HARP Experiment. G. Vidal-Sitjes (INFN-Ferrara) on behalf of the HARP Collaboration

The R&D study for the KLOD experiment. at IHEP (Protvino) U-70 proton

XMASS 1.5, the next step of the XMASS experiment

Calibration of large water-cherenkov Detector at the Sierra Negra site of LAGO

Electromagnetic calorimetry for the ILC

σx=2.5cm, slpx =33mrd

arxiv: v1 [nucl-ex] 3 Feb 2015

clfv searches using DC muon beam at PSI

Performance of muon and tau identification at ATLAS

PoS(PhotoDet 2012)010

Digital Imaging Calorimetry for Precision Electromagnetic and Hadronic Interaction Measurements

PoS(Hadron 2013)182. Search for deeply-bound K-nuclear states via the. 3 He(inflight-K, n) reaction at J-PARC

Transcription:

Performance study of the TOP counter with the 2 GeV/c positron beam at LEPS, For the Belle II PID group KMI, Nagoya University E-mail: matsuoka@hepl.phys.nagoya-u.ac.jp The TOP (Time-Of-Propagation) counter is a novel ring-imaging Cherenkov detector for particle identification in the Belle II experiment. It mainly consists of a 2.7 m long quartz radiator bar and 32 micro-channel-plate photomultiplier tubes (MCP-PMTs). It measures the time of propagation of the Cherenkov photons in the quartz bar with a resolution of 50 ps to reconstruct the Cherenkov ring image in the detection time and position plane. A prototype TOP counter which was close to the final design was tested with a 2 GeV/c positron beam at LEPS (Laser Electron Photon facility at SPring-8). We obtained a beautiful pattern of the Cherenkov image and understood the quartz optics and the MCP-PMT performance well. We also succeeded in reconstructing the speed of the positron event-by-event as expected. Technology and Instrumentation in Particle Physics 2014, 2-6 June, 2014 Amsterdam, the Netherlands Speaker. c Copyright owned by the author(s) under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike Licence. http://pos.sissa.it/

1. Introduction The TOP (Time-Of-Propagation) counter [1 6] is a novel ring imaging Cherenkov detector for particle identification (PID) in the Belle II experiment [7]. It aims to identify up to 3 GeV/c kaons and pions with a pion efficiency of 95% and a fake-pion rate of 5% or better. The TOP counter mainly consists of a 260 45 2 cm 3 quartz radiator bar, a 10 cm long quartz prism, a spherical mirror (6.5 m in radius of curvature) and two rows of 16 micro-channel-plate photomultiplier tubes (MCP-PMTs) [8 12] as shown in Fig. 1. It is a compact and nonmassive detector, which is suitable for the collider experiment. Cherenkov photons generated in the quartz bar by a charged particle propagate in the bar as they are totally reflected on the boundaries between the quartz and the air. The path of the Cherenkov photons to the MCP-PMTs, or the time of propagation, depends on the Cherenkov angle or the speed of the charged particle. By measuring the time of propagation of the Cherenkov photons as well as the time of flight of the charged particle for about 1 m in addition to the momentum, position and angle of the charged particle measured by the inner trackers, the TOP counter identifies the mass of the charged particle. The number of Cherenkov photons detected by the MCP-PMTs is about 20 per particle. To achieve the aimed PID performance it is essential for the TOP counter to propagate the Cherenkov image undistorted without photon loss, to detect the photons with a high efficiency and to measure the time of propagation of each photon with a time resolution better than 50 ps. The quartz components and the MCP-PMT were developed in success. Their performance is described in this paper. A prototype TOP counter was assembled and its performance was evaluated with a 2 GeV/c positron beam at LEPS (Laser Electron Photon facility at SPring-8) [13]. The results of the beam test are also discussed. 2. TOP counter components 2.1 Quartz bar The Cherenkov photons reach the MCP-PMTs after an order of 100 reflections on the quartz bar surfaces. To maintain the Cherenkov image on the reflections the quartz bar surfaces have to be flat and in parallel with the facing surface. To minimize the loss of the Cherenkov photons K orπ Mirror TOP TOF (~1 m) 2 cm e + Prism e Figure 1: Schematic view of the TOP counter. An example of a charged particle (kaon or pion) trajectory and one path of the Cherenkov light in the quartz is indicated in this figure. 2

Length 1250 ± 0.50 mm Width 450 ± 0.15 mm Thickness 20 ± 0.10 mm Flatness < 6.3 µm Parallelism < 4 arcsec Roughness < 5 Å (RMS) Prism Two bars Mirror Table 1: Part of the quartz bar specifications. The flatness, parallelism and roughness are for the largest surfaces. Figure 2: Photograph of the glued quartz bars, mirror and prism of the prototype TOP counter. The quartz component is indicated with the dashed line. the surfaces have to be smooth. Thus the specifications of the quartz bar are determined as listed in Table 1. Less than 6.3 µm flatness and less than 4 arcsec parallelism are required to keep displacement of the Cherenkov photon at the MCP-PMT within the position resolution of the MCP- PMT. Less than 5 Å(RMS) roughness is required to keep loss of the Cherenkov photons at the reflections before reaching the MCP-PMT less than 20%. Because it is difficult to polish a long quartz bar, two 125 cm long bars are polished separately by companies and then are glued together with optical adhesive of high transmittance. On the both ends of the 250 cm long bar a 10 cm long quartz bar whose spherical end is coated with the aluminum mirror and a 10 cm long quartz prism are also glued. The spherical shape of the mirror is meant to reduce the chromatic error of the Cherenkov light [14]. For the prototype TOP counter, all the quartz components were glued together successfully as shown in Fig. 2. The dimensions are the same as the final ones except the length of the bar and the mirror radius of curvature. The length of the prototype is shorter by 61 mm and the radius is 5.0 m. The internal surface reflectance and bulk transmittance of the quartz bars were measured to be greater than 99.90% and greater than 98.5%/m, respectively. They satisfy our requirements. 2.2 MCP-PMT The MCP-PMT for the TOP counter was developed at Nagoya University in collaboration with HAMAMATSU Photonics K.K. To cover the end face of the prism with a small dead region, it is 27.6 27.6 mm 2 square in shape. The photocathode size is 23 23 mm 2 and the anode size is 22 22 mm 2. The anode is divided by 4 4. The photocathode is made of NaKSbCs. The quantum efficiency (QE) as a function of the wavelength is shown in Fig. 3. The maximum QE is typically 28% around 360 nm wavelength. The MCP-PMT contains two 400 µm thick MCPs to have enough gain (greater than 5 10 5 in 1.5 T) for single photon detection. The diameter and the bias angle of the micro channel of the MCP are 10 µm and 13 degrees, respectively. The aperture ratio of the MCP is about 60%. Because the photoelectron is multiplied in these thin MCPs, the MCP-PMT has a small transit time spread (TTS) less than 40 ps. Figure 4 shows a distribution of the hit timing for single photons from a pico-second pulse laser measured by a CAMAC TDC. The TTS is defined by the standard deviation of the Gaussian fitted to the peak of the distribution. The tail on the right side of the peak corresponds to events where the photoelectron bounces on the first MCP surface [15]. 3

QE 0.3 0.25 0.2 0.15 0.1 0.05 300 400 500 600 wavelength Figure 3: Typical QE of the MCP-PMT as a function of the wavelength. 2.3 Readout electronics 1500 1000 500 Entries 16891 Mean 1.541 RMS 6.91 χ 2 / ndf 34.8 / 5 Constant 1754 ± 29.1 Mean -1.035 ± 0.020 Sigma 1.461 ± 0.018 0-20 -10 0 10 20 30 40 TDC (26.3 ps/count) Figure 4: Hit timing distribution of the MCP- PMT for single photons. A Gaussian is fitted to the peak of the distribution. A multi-gigasample per second waveform sampling ASIC, called IRS, developed at Hawaii University is used for the front-end readout electronics of the TOP counter. Figure 5 (left) shows a prototype of the front-end module used for the beam test. It consisted of an array of the IRS3B ASICs controlled by FPGAs. The digitized waveforms were sent via a fiber-optic cable to the backend which was composed of a COPPER/FINESSE data acquisition system [16, 17]. The prototype TOP counter was equipped with full 32 MCP-PMTs and the four front-end modules. The total number of MCP-PMT anode channels was 512 though 90 channels were not read out in the beam test due to some problems. Another readout electronics shown in Fig. 5 (right) was also used in the beam test. The frontend module consisted of four constant fraction discriminator (CFD) boards where the MCP-PMT signal was amplified and digitized to a differential ECL (Emitter-Coupled Logic) signal. The ECL signal was sent via a twisted pair cable to a VME TDC, CAEN V1290A. The TDC has a timing Figure 5: Photographs of the IRS3B front-end module with eight MCP-PMTs (left) and the CFD front-end module with two MCP-PMTs (right). 4

resolution of about 20 ps after a dedicated calibration. The timing resolution of the CFD readout system was tested with a test pulse. It was consistent with the TDC resolution. To reduce the number of readout channels, the 16 outputs of each MCP-PMT were merged into four at the MCP- PMT socket. Therefore the number of readout channels of the prototype TOP counter was 128 in case of the CFD readout. 3. Performance study of the TOP counter To study the performance of the TOP counter, the prototype TOP counter was tested with the 2 GeV/c positron beam at LEPS. Two different data sets were taken with the IRS3B and CFD readout systems. 3.1 Setup of the beam test At the LEPS beam line a high energy photon beam (less than 2.4 GeV) is available. It is produced by the backward Compton scattering of 355 nm laser photons on the 8 GeV electron beam in the SPring-8 synchrotron. The setup of the beam test is shown in Fig. 6. The photon beam impinged on a 1.5 mm thick Pb target to create electron and positron pairs. The momentum of the pairs was measured by the LEPS spectrometer; a dipole magnet operated at 0.7 T, three drift chambers (DC1, DC2 and DC3) and a wall of TOF counters. To trigger on 2 GeV/c positrons, two pairs of 40 40 mm 2 and 5 5 mm 2 scintillation trigger counters were put between DC3 and the TOF counters. The distance between the pairs was about 1 m. The TOP counter was put between the trigger counters so that the beam incident angle was normal to the quartz bar. The beam hit position was about 135 cm away from the MCP-PMT array. The trigger was issued at the coincidence of the four trigger counters and the trigger rate was about 10 Hz. The hit position and angle on the quartz bar was monitored by two pairs of vertical and horizontal scintillating fiber trackers. Each tracker consisted of double layers of five scintillating fibers whose diameter and interval were 2 mm and 2.2 mm, respectively. The fluctuation of the beam angle measured by the trackers was about 1.8 mrad. To eliminate electromagnetic shower events, the number of hit TOF counters was required to be one. The beam timing (t 0 ) was obtained from the accelerator RF Drift chambers (DC1, 2, 3) γbeam Pb target (1.5 mm) e Dipole magnet (0.7 T) e + TOF counters TOP counter Trigger (40 40 mm 2 ) 2 Trigger (5 5 mm 2 ) 2 DC3 TOP counter Tracker x/y 2 Timing counter TOF counters Figure 6: Setup of the beam test at LEPS. (Left) Top view of the LEPS spectrometer. (Right) Side view of the beam test setup. 5

number of hits / 25 ps / event 0.006 0.005 0.004 0.003 0.002 0.001 0 0 10000 20000 30000 40000 50000 time (ps) Figure 7: Accumulated distribution of the MCP-PMT hit timing for a center channel measured by the CFD readout (hatched histogram). The PDF (line) is overlaid. signal. The t 0 resolution was measured to be about 30 ps using a Cherenkov timing counter which consisted of a quartz block and an MCP-PMT. 3.2 Results of the beam test The MCP-PMT hit timing relative to t 0 was recorded for each channel. Figure 7 shows the accumulated distribution of the hit timing for a channel at the center of the MCP-PMT array measured by the CFD readout. The earliest peak around 9.2 ns corresponds to the Cherenkov photons which are generated in the direction toward the MCP-PMT and reach the channel via the shortest path. The Cherenkov photons generated in the other directions are reflected on the sides of the quartz bar and make the following peaks. Those reflected on the mirror appear after 26 ns. The component earlier than the first peak originates from electromagnetic showers. In this figure the probability density function (PDF) calculated analytically is overlaid and it agrees well with the data. The height of each peak depends on the quartz surface reflectance and transmittance, the QE of the MCP-PMT and the QE dependence on the photon incident angle and polarization [12]. The width of each peak is determined mainly by the chromatic dispersion of the Cherenkov light and the TTS of the MCP-PMT. The tail on the right side of each peak is made by the bounce of the photoelectron on the first MCP surface as shown in Fig. 4 and a cross-talk of the MCP-PMT signal to the adjacent channels. Therefore the agreement of the height, width and tail of each peak means that the quartz optics and the performance of the MCP-PMT are well understood. Figure 8 shows the two-dimensional accumulated hit distribution measured by the IRS3B readout and the expected one by a Monte Carlo simulation (MC) based on the Geant4 simulation toolkit [18, 19]. The pattern of the Cherenkov image matches between the data and MC. In the data, differences of the time origin among the channels due to the electronics were corrected using the hit timing for a pulse laser which was irradiated to the MCP-PMTs through the quartz bar. The number of hits per event distributed as shown in Fig. 9. The mean number of hits is 32.0 for the CFD data and 32.6 for the MC. This agreement also supports our understanding of the quartz optics and the photon detection efficiency of the MCP-PMT and the CFD electronics. The 6

time (ns) 70 80 90 100 110 Data (IRS3B) Simulation Beam 10 3 10 2 10 120 0 200 400 1 channel time (ns) 50 40 30 20 10 0 200 400 channel 10 3 10 2 10 1 0 64 448 1 65 2 66 63 511 Figure 8: Accumulated hit distribution measured by the IRS3B readout (left) and the expectation by the MC (center). The vertical blank bands correspond to the dead channels. The channel number is assigned as shown in the right figure, which is a schematic view of the prism end. 1000 800 600 400 200 Preliminary data Entries 16471 Mean 32.04 RMS 9.454 MC Entries 100000 Mean 32.64 RMS 8.603 0 0 10 20 30 40 50 60 70 80 number of hits / event Figure 9: Number of hits per event measured by the CFD readout. The hatched histogram is the estimation by the MC. It is normalized to the number of data events. 1000 800 600 400 200 0 Preliminary data Entries 16471 Mean 1 RMS 0.006 MC Entries 100000 Mean 1 RMS 0.007239 0.96 0.98 1 1.02 1.04 β Figure 10: Reconstructed β from the CFD data. The hatched histogram represents the reconstructed β for the MC. It is normalized to the number of data events. MC also well represents the electromagnetic shower background, which appears in the tail on the right side of the number of hits distribution. For the two-dimensional measurements of the hit timing and channel taken by the CFD readout, the speed of the incident positron relative to the one of light in vacuum (β) was reconstructed event-by-event with a maximum likelihood method. For the 2 GeV/c positron β equals 1.0000. The distribution of the reconstructed β is shown in Fig. 10. The mean and RMS of the distribution are 1.0005 and 0.0060, respectively. They are nearly consistent with the MC, where the mean is 1.0004 and the RMS is 0.0072. The slight discrepancy of the distributions is under investigation. 7

4. Conclusions The TOP counter is a novel ring imaging Cherenkov detector for particle identification in Belle II. The main components of the TOP counter, the quartz bar and the MCP-PMT, were developed in success. Their performance was confirmed by testing the prototype TOP counter with the 2 GeV/c positron beam at LEPS. The performance of the TOP counter was evaluated by reconstructing β of the positron event-by-event; the mean and RMS of the β distribution was 1.0005 and 0.0060, respectively, which were nearly consistent with the expectation by the MC. Acknowledgments This work was supported by MEXT Grant-in-Aid for Scientific Research on Innovative Areas Elucidation of New Hadrons with a Variety of Flavors. We acknowledge assistance of the LEPS collaboration to the beam test. References [1] M. Akatsu, et al., Nucl. Instr. and Meth. A 440 (2000) 124. [2] T. Oshima, ICFA Instrumentation Bulletin 20 (2000) 2. [3] T. Oshima, Nucl. Instr. and Meth. A 453 (2000) 331. [4] Y. Enari, et al., Nucl. Instr. and Meth. A 494 (2002) 430. [5] Y. Enari, et al., Nucl. Instr. and Meth. A 547 (2005) 490. [6], For the Belle II PID Group, Nucl. Instr. and Meth. A 732 (2013) 357. [7] T. Abe, et al., KEK-REPORT-2010-1, 2010. [8] M. Akatsu, et al., Nucl. Instr. and Meth. A 528 (2004) 763. [9] K. Inami, et al., Nucl. Instr. and Meth. A 592 (2008) 247. [10] N. Kishimoto, et al., Nucl. Instr. and Meth. A 564 (2006) 204. [11] T. Jinno, et al., Nucl. Instr. and Meth. A 629 (2011) 111. [12] (For the Belle II PID group), Nucl. Instr. and Meth. A (2014), http://dx.doi.org/10.1016/j.nima.2014.05.003. [13] T. Nakano, et al., Nucl. Phys. A 64 (2001) 71. [14] Y. Arita, Phys. Procedia 37 (2012) 621. [15] C. Field, et al., Nucl. Instr. and Meth. A 553 (2005) 96. [16] Y. Igarashi, et al., econf C0303241 (2003) TUGP009. [17] T. Higuchi, et al., econf C0303241 (2003) TUGT004. [18] S. Agostinelli, et al., Nucl. Instr. and Meth. A 506 (2003) 250. [19] J. Allison, et al., IEEE Trans. Nucl. Sci. 53 (2006) 270. 8