Welcome to the New Look ICP-MS Journal!

Similar documents
Accurate Analysis of Trace Mercury in Cosmetics using the Agilent 8900 ICP-QQQ

Application note. Trace level analysis of sulfur, phosphorus, silicon and chlorine in NMP using the Agilent 8800 Triple Quadrupole ICP-MS

Determination of trace elements in ultrapure semiconductor grade sulfuric acid using the Agilent 8900 ICP-QQQ in MS/MS mode

The ultratrace determination of iodine 129 in aqueous samples using the 7700x ICP-MS with oxygen reaction mode

Accurate analysis of neptunium 237 in a uranium matrix, using ICP-QQQ with MS/MS

Ultra trace measurement of potassium and other elements in ultrapure water using the Agilent 8800 ICP-QQQ in cool plasma reaction cell mode

Determination of challenging elements in ultrapure semiconductor grade sulfuric acid by Triple Quadrupole ICP-MS

Lead isotope analysis: Removal of 204 Hg isobaric interference from 204 Pb using ICP-QQQ in MS/MS mode

Trace elemental analysis of distilled alcoholic beverages using the Agilent 7700x ICP-MS with octopole collision/ reaction cell

Direct Measurement of Metallic Impurities in 20% Ammonium Hydroxide by 7700s/7900 ICP-MS

Direct Analysis of Trace Metal Impurities in High Purity Nitric Acid Using ICP-QQQ

Analysis of Trace Metal Impurities in High Purity Hydrochloric Acid Using ICP-QQQ

Agilent 8900 Triple Quadrupole ICP-MS

Agilent s New 8800 ICP-QQQ. Transforming ICP-MS Technology

Enhancing the productivity of food sample analysis with the Agilent 7700x ICP-MS

Multi-Element Analysis of Petroleum Crude Oils using an Agilent 7900 ICP-MS

Application note. Accurate determination of sulfur in biodiesel using Isotope Dilution-Triple Quadrupole ICP-MS (ID-ICP-QQQ) Petrochemical

Rapid Analysis of High-Matrix Environmental Samples Using the Agilent 7500cx ICP-MS. Application. Author. Abstract. Introduction.

Determination of Impurities in Silica Wafers with the NexION 300S/350S ICP-MS

Multi-Element Analysis of Cannabis using the Agilent 7800 ICP-MS

Quantitative Analysis of Opioids Using a Triple-Quadrupole GC/MS/MS

Semiquantitative Screening of Pharmaceutical Antiviral Drugs using the Agilent 7500ce ICP-MS in Helium Collision Mode

Simple, reliable analysis of high matrix samples according to US EPA Method 6020A using the Agilent 7700x/7800 ICP-MS

THE NEW QUANTITATIVE ANALYTICAL METHOD FOR ULTRATRACE SULFUR COMPOUNDS IN NATURAL GAS

Thermo Scientific icap TQ ICP-MS: Typical limits of detection

Accurate measurement of elemental impurities in metals and metal alloys using the Thermo Scientific icap TQ ICP-MS

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

Determination of ultratrace elements in photoresist solvents using the Thermo Scientific icap TQs ICP-MS

Techniques for the Analysis of Organic Chemicals by Inductively Coupled Plasma Mass Spectrometry (ICP-MS)

Tomorrow s quantitation with the TSQ Fortis mass spectrometer: quantitation of phenylephrine hydrochloride for QA/QC laboratories

AUTOMATED ONLINE IDENTIFICATION AND MONITORING OF IMPURITIES IN GASES

New Dynamic MRM Mode Improves Data Quality and Triple Quad Quantification in Complex Analyses

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Application Note. Gas Chromatography/Mass Spectrometry/Food Safety. Abstract. Authors

Applications of ICP-MS for Trace Elemental Analysis in the Hydrocarbon Processing Industry

The Agilent 7700x ICP-MS Advantage for Drinking Water Analysis

Agilent ICP-MS. Fundamentals of ICP-MS Analysis and Its Applications for Low Level Elemental Determination in Cannabis

Simultaneous quantification of peptides and phosphopeptides by caplc-icp- MS using the Agilent 8800/8900 Triple Quadrupole ICP-MS

Agilent ICP-MS Journal December 2016 Issue 67

Determination of major, minor and trace elements in rice fl our using the 4200 Microwave Plasma- Atomic Emission Spectrometer (MP-AES) Authors

Implementing EPA Method 6020 with the Agilent ICP-MS Portfolio

Analysis of Opioids Using Isotope Dilution with GCMS-TQ8030 GC/MS/MS. No. GCMS No. SSI-GCMS-1401

Analysis of Arsenic, Selenium and Antimony in Seawater by Continuous-Flow Hydride ICP-MS with ISIS

Hydride Generation for the Determination of As, Sb, Se and Bi Using the Teledyne Leeman Lab s Prodigy 7 ICP-OES

High Throughput Water Analysis using Agilent 7900 ICP-MS coupled with ESI prepfast

Total Elemental Analysis of Food Samples for Routine and Research Laboratories, using the Thermo Scientific icap RQ ICP-MS

High-Speed Environmental Analysis Using the Agilent 7500cx with Integrated Sample Introduction System Discrete Sampling (ISIS DS)

Determination of VOCs by USEPA Method 8260 with Extended Dynamic Range using Fast, Sensitive Capillary GC/MS

Elemental analysis of river sediment using the Agilent 4200 MP-AES

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

Arsenic Speciation in Chicken. Mary Carson, Ph.D. FDA/CVM/OR/ Division of Residue Chemistry

Accurate Determination of TiO 2 Nanoparticles in Complex Matrices using the Agilent 8900 ICP-QQQ

Determination of Chromium in Gelatin Capsules using an Agilent 7700x ICP-MS

Comparing Collision/Reaction Cell Modes for the Measurement of Interfered Analytes in Complex Matrices using the Agilent 7700 Series ICP-MS

Speciation of Bromine Compounds in Ozonated Drinking Water using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry

Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma

Agilent Technologies at TIAFT 2013

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma

Determination of Phosphorus and Sulfur with Dynamic Reaction Cell ICP-MS

Agilent J&W PoraBOND Q PT Analyzes Oxygenates in Mixed C4 Hydrocarbon Streams by GC/FID and GC/MSD

Plasma-free Metanephrines Quantitation with Automated Online Sample Preparation and a Liquid Chromatography-Tandem Mass Spectrometry Method

Highly Sensitive and Rugged GC/MS/MS Tool

Thermo Scientific icap RQ ICP-MS: Typical limits of detection

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer

Trace Analyses in Metal Matrices Using the ELAN DRC II

Analytical Approaches to Arsenic

Basic and Application Inductively coupled plasma mass spectrometry (ICPMS)

Advances in Interference Removal for Accurate Arsenic Analysis in Food and Beverages

Isotope Dilution Mass Spectrometry

Single Nanoparticle Analysis of Asphaltene Solutions using ICP-QQQ

Improved Throughput and Reproducibility for Targeted Protein Quantification Using a New High-Performance Triple Quadrupole Mass Spectrometer

Agilent 7500a Inductively Coupled Plasma Mass Spectrometer (ICP-MS)

Application of the Agilent 7900 ICP-MS with Method Automation function for the routine determination of trace metallic components in food CRMs

Supporting Information

Quantitative analysis of high purity metals using laser ablation coupled to an Agilent 7900 ICP-MS

Determination of N-Nitrosamines by USEPA Method 521 using Triple Quadrupole Gas Chromatography Mass Spectrometry

All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems

Analysis of Biomarkers in Crude Oil Using the Agilent 7200 GC/Q-TOF

Autenticity control, provenance testing and fraud detection using mass spectrometry

Analysis of domestic sludge using the Agilent 4200 MP-AES

Rapid determination of five arsenic species in polished rice using HPLC-ICP-MS

Fast Determination of Impurities in Propane- Propylene Streams Using a Pulsed Flame Photometric Detector (PFPD) and a New Capillary.

Low Level Detection of Priority Inorganic Pollutants in Water. Anthony Neumann, MSc Darren Crichton, BSc

Rapid and Accurate Forensics Analysis using High Resolution All Ions MS/MS

Insights Into the Nanoworld Analysis of Nanoparticles with ICP-MS

Monomer Analysis. Analysis by Gas Chromatography WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Determination of Hormones in Drinking Water by LC/MS/MS Using an Agilent InfinityLab Poroshell HPH Column (EPA 539)

Authors: C. Derrick Quarles, Jr. *, Patrick Sullivan, M. Paul Field, Hwan Kim, and Daniel R. Wiederin

Thermo Scientific ConFlo IV Universal Interface. Continuous Flow Interface. Isotope Ratio MS

Analyze Hydrocarbon Impurities in 1,3-Butadiene with an Agilent J&W GS-Alumina PT Column

IMPROVING DATA QUALITY WITH ADVANCED INSTRUMENTATION UTILIZING MULTIPLE INTERFERENCE REDUCTION TECHNOLOGIES

Ultra-fast determination of base metals in geochemical samples using the 5100 SVDV ICP-OES

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

Agilent 8900 Triple Quadrupole ICP-MS LEAVE INTERFERENCES BEHIND WITH MS/MS

Identification and Quantitation of PCB Aroclor Mixtures in a Single Run Using the Agilent 7000B Triple Quadrupole GC/MS

The Characterization of Nanoparticle Element Oxide Slurries Used in Chemical-Mechanical Planarization by Single Particle ICP-MS

FORENSIC TOXICOLOGY SCREENING APPLICATION SOLUTION

Benefits of Equipping your Lab with a Time-of-Flight Mass Spectrometer

Evaluation of a New HPLC, a New Tandem MS and a New Data Processing Software for General Clinical Use

China Soil Pollution Survey: Elemental Analysis of Soil and Sediment Digests by ICP-MS

Transcription:

Agilent ICP-MS Journal February 2018. Issue 71 Welcome to the New Look ICP-MS Journal! Page 1 Welcome to the New look ICP-MS Journal Page 2-4 Analysis of Volatile Arsenic Compounds in Gas and Liquefied Gas Samples by GC-ICP-MS Page 5-6 Interference-Free Measurement of Trace Mercury in Tungsten- Rich Cosmetic Samples using ICP-QQQ Ed McCurdy, ICP-MS Product Marketing, Agilent UK The first issue of Agilent s ICP-MS Journal was published in September 1998, under the Hewlett-Packard Company brand. There have been many developments in ICP-MS technology since then, together with changes in the markets, regulations, and applications that the technique addresses. Over the years, we ve reported on many of the key innovations and applications in this exciting field. As the number of Agilent ICP-MS users continues to grow, our mission is to continue to keep you informed of key trends in the field of plasma spectrochemistry. Check out the ICP-MS Journal archive at https://www.agilent.com/en-us/ newsletters/icpmsjournal Page 7 Japan Hosts Another Successful Asia Pacific Winter Plasma Conference Page 8 On-Demand Webinars; Agilent ICP-MS Publications We welcome your input, whether you d like to contribute an article, send feedback or ask a question. Please contact the Journal editor at icpms@agilent.com

Agilent ICP-MS Journal February 2018, Issue 71 Analysis of Total Arsenic and Volatile As Compounds in Gas and Liquefied Gas Samples by GC-ICP-MS Laura Freije-Carrelo 1, Mariella Moldovan 1, J. Ignacio García Alonso 1, Thuy Diep Thanh VO 2, Jorge Ruiz Encinar 1 1 University of Oviedo, Oviedo, Spain; 2 Borealis Polyolefine GmbH, Linz, Austria Introduction Volatile metal(loid) elements and compounds are present in many different types of gas and liquefied gas samples, such as natural gas and biogas. Arsenic is one of the most prevalent elemental impurities in such sample-types and its presence in monomer gases such as ethylene and propylene affects the properties of the polymers produced from these gases. Volatile forms of As are also highly active catalyst poisons, so the element must be carefully monitored and controlled in the petrochemical and polymer industries. Importantly, the toxicity of As depends on the chemical species, with arsine being the most toxic form. Reliable analytical methods are required for both total and speciation analysis of arsenic compounds in gaseous samples. This study presents a novel GC-ICP-MS method to simultaneously perform arsenic speciation analysis and total elemental As determination in one measurement. Experimental Gas standards and samples: An arsine (AsH 3 ) standard in N 2 (Linde AG, Germany) was used for quantification purposes. Liquefied butane pressurized under N 2 and doped with arsine (ISGAS, USA), and a real propylene sample from a cracker plant (Borealis, Sweden) were analyzed. Instrumentation: An Agilent 7890B GC equipped with two interconnected gas sampling valves and a J&W GS- GasPro column (60 m, 0.32 mm i.d.) was used. The GC was coupled to an Agilent 7900 ICP-MS using Agilent s heated GC-ICP-MS interface (G3158D). A gas dilutor GasMix Aiolos II and a vaporizer chamber (Alytech, France) were used for online dilution of the samples and standards. Optimized GC and ICP-MS parameters are summarized in Table 1. Details of the novel GC-ICP-MS configuration and operating conditions can be seen in References 1 and 2. Table 1. Optimized GC and ICP-MS parameters. GC parameters Column flow (ml/min) 3 Transfer line flow (ml/min) 5 Oven gradient Injection mode 40 to 250ºC in 5 min 2 min at 250ºC Split Split ratio 1:6 GC-ICP-MS interface temp (ºC) 250 ICP-MS parameters Cell gas modes No gas He RF power (W) 1600 Sampling depth (mm) 8 Dilution gas (L/min) 0.3-0.4 Nitrogen flow (ml/min) 10 Extraction Lens 1 (V) 0 2

February 2018, Issue 71 Agilent ICP-MS Journal Results and Discussion An arsine in nitrogen standard was used for the optimization of the system operating conditions. Chromatograms of a 68 ppb (v/v) arsine standard in nitrogen and a N 2 blank are shown in Figure 1. The N 2 blank chromatogram is shown on a y-axis scale that is approximately two orders of magnitude lower than the scale used for the arsine sample. As can be seen, the first peak in the arsine standard chromatogram appears at 0.2 min, corresponding to the total arsenic eluted from the inert transfer line (column bypass flow). A second peak is observed at 3.8 min corresponding to the speciation analysis (arsine eluted from the column). The chromatograms demonstrate that total and speciation analysis can be performed simultaneously within the same injection. Note that an accurate and precise split ratio is assumed for such mass balance calculations. Moreover, the arsenic peak coelutes with the sample matrix in the total analysis (column bypass) measurement, so sensitivity may not be consistent for both direct and GC conditions. These two facts could explain the significant uncertainty (12% RSD) observed for the calculated recovery. Calibration: Calibration curves were generated for total As and speciation (AsH 3 ) analysis based on AsH 3 standard levels from 0.2 ppb to 68 ppb, as shown in Figure 2. The method showed very good linearity within the tested range of concentration for both total (r 2 = 0.9996) and speciation analysis (r 2 = 0.998). Detection limits of 2 ppt for total As and 12 ppt for AsH 3 by speciation analyses were obtained. To the best of our knowledge, these are the lowest DLs for direct total As and AsH 3 speciation analysis in gaseous samples ever reported in the literature. Figure 1. Chromatogram of arsine in nitrogen (68 ppb, v/v). (Reprinted with permission from Laura Freije-Carrelo et al, Anal. Chem., 2017, 89 (11), pp 5719 5724. Copyright 2017 American Chemical Society). The difference in the peak area observed for total and speciation analysis is due to the split ratio used (1:6) in the GC injector. No adsorption or loss of analyte is expected in the inert transfer line. Therefore the comparison between the experimentally obtained and the expected theoretical GC inlet split ratio can be used to assess if the total As observed is exclusively in the form of arsine or if other As species are present in the sample. Integration of peak areas for the total As and arsine in each point of a calibration curve from 0.2 to 68 ppb (n = 13) showed a mean recovery for the arsine peak of 89 ± 11 % of the total As in the standard. This indicates that, as expected, As is exclusively present as arsine in the standard. Figure 2. Calibration curves for total As (red points) and arsine (blue points) using arsine standards. Synthetic sample analysis: Liquefied butane doped with a non-certified level of arsine was analyzed as a synthetic sample. He cell mode was used for analysis of the samples to minimize the occurrence of polyatomic interferences. The vaporization chamber was set at 120 ºC and connected on-line with the gas dilutor for vaporization of the sample. A chromatogram of this sample diluted 1:7 in Ar is shown in Figure 3. Results obtained for total and speciation analysis are given in Table 2. 3

Agilent ICP-MS Journal February 2018, Issue 71 This synthetic sample was also analyzed by the producer (ISGAS) and an independent lab, with results of 218 and 40 ppb, respectively. The wide range of these results illustrates the difficulty of developing a method for the reliable analysis of gaseous and liquified gas samples. However, the results of ~95 ppb obtained in this work (given in Table 2) are within the range of concentrations obtained by the other two laboratories, giving confidence in the applicability of the new GC-ICP-MS method. Conclusions The novel GC-ICP-MS method has been shown to be suitable for the direct, simultaneous quantitative analysis (total and speciation) of ICP-detectable elements such as As present in gas and liquefied gas samples. Detection limits in the low ppt levels were obtained for both total As and speciated As analysis without the need for a preconcentration step. The new method is fast (5 min per injection), making it convenient for implementation in industrial laboratories, where rapid determination of contaminants is required to support acceptance or rejection of a stock gas. References and More Information 1. Laura Freije-Carrelo et al., Instrumental Setup for Simultaneous Total and Speciation Analysis of Volatile Arsenic Compounds in Gas and Liquefied Gas Samples, Anal. Chem. 2017, 89, 5719 5724 2. Agilent publication, 2017, 5991-8799EN Figure 3. As chromatograms of doped liquefied butane and butane blank diluted 1:7. Actual sample analysis: A real propylene sample containing both gas and liquefied phases was analyzed. The vaporization chamber was set at 120 ºC and connected on-line with the gas dilutor for vaporization of the liquid phase of the sample. For the gas phase analysis, the sample was introduced directly into the gas dilutor. Quantitative results are given in Table 2. The results demonstrate that the method could also be used to assess the partition of total As and its species between gas and liquid phases of liquefied gas samples. Table 2. Quantitative results (ppb As, v/v) obtained for liquefied butane and propylene samples. Expanded uncertainties (95% confidence level) are given (not including the uncertainty of the arsine standard). Arsenic Liquefied butane Propylene (gas phase) Propylene (liquid phase) Total analysis 92 ± 4 54 ± 4 34 ± 3 Speciation analysis 95 ± 4 53 ± 13 31 ± 5 4

February 2018, Issue 71 Agilent ICP-MS Journal Interference-Free Measurement of Trace Mercury in Tungsten-Rich Cosmetic Samples using ICP-QQQ Xiang-cheng Zeng 1, Ke Wang 2, Xin-mei Wang 2, Juan-e Song 1, and Donna Hsu 1 1 Agilent Technologies Co. Ltd, China. 2 Shanghai Institute for Food and Drug Control, China Introduction Many mercury (Hg) compounds are toxic, causing symptoms ranging from skin irritation, headaches, and tremors, through to nervous system damage and renal failure. Because Hg compounds are easily absorbed through the skin, their use in cosmetics is controlled. For example, the US Food and Drug Administration (FDA) does not allow Hg in cosmetics, except under specific conditions where there are no other safe and effective preservatives available [1]. Increasingly, however, Hg has been found in cosmetic products such as skin creams, soap, and lotions sold as anti-aging or skin lightening. Analysis of Hg by ICP-MS: Hg is a challenging element to determine at low levels by ICP-MS. It has a high first ionization potential (10.44 ev), so is relatively poorly ionized in the plasma, leading to low sensitivity. Also, Hg has seven naturally occurring isotopes, each with relatively low % abundance, further reducing sensitivity. Despite these difficulties, ICP-MS can still be used successfully to perform trace-level analysis of Hg. However, some cosmetics contain large amounts of tungsten (W). This leads to polyatomic interferences from WO + and WOH + that affect all the Hg isotopes, making Hg measurement even more challenging. For example, the most abundant Hg isotopes, 200 Hg and 202 Hg, suffer overlaps from 184 W 16 O + and 186 W 16 O +, respectively. Conventional single quadrupole ICP-MS (ICP-QMS) fitted with a collision/ reaction cell (CRC) is unable to resolve the WO + and WOH + interferences sufficiently to allow the accurate determination of Hg at trace levels. In this study, the superior interference removal capability of triple quadrupole ICP-MS (ICP-QQQ) in MS/MS mode with O 2 cell gas was used for on-mass detection of Hg in a tungsten matrix. 200 Hg + and WO + ions at m/z 200 enter the CRC. WO + + reacts with O 2 cell gas to form WO 2 and WO 3+, shifting to higher masses. Hg + does not react and so remains at m/z 200. Q2 is set to 200 u, allowing 200 Hg + ions to pass to the detector free of interference. In MS/MS, reaction chemistry is controlled and consistent because only the target analyte mass enters the CRC. This capability offers a much more predictable and reliable approach to resolving interferences on a wide range of elements. Experimental Standards and samples: Mercury standards were prepared in 0.5 % high purity hydrochloric acid (TAMA- Pure-AA-100, Kanagawa, Japan). A tungsten-rich cosmetic sample was bought from a local store in Shanghai. The liquid sample was weighed to the nearest 0.100 g, and then diluted 100-fold with Milli-Q de-ionized water acidified with 0.5 % HCl. The sample was shaken for a couple of minutes to ensure it was fully homogenized. Instrumentation: An Agilent 8900 Standard configuration ICP-QQQ was used. The standard sample introduction system was used, comprising a glass concentric nebulizer, quartz double-pass spray chamber, 2.5 mm injector quartz torch, and Ni interface cones. The ICP-QQQ was operated in no gas mode, with He cell gas, and with O 2 cell gas in both single quad (SQ) and MS/MS modes. Results and Discussion Multiple isotope analysis study: To demonstrate the ability of MS/MS to resolve interferences on multiple isotopes, a scan spectrum comparison was made. The mass range of the Hg isotopes was acquired for a simple Hg standard and a solution containing the same concentration of Hg spiked into a high W matrix. The overlaid spectra are shown in Figure 1, confirming that the measured isotopic abundances match the natural Hg isotope pattern despite the presence of the high W matrix in the second sample. 5

Agilent ICP-MS Journal February 2018, Issue 71 isotopes shows that O 2 in MS/MS mode can simultaneously remove polyatomic interferences from all five Hg isotopes. The results obtained using O 2 cell gas in single-quad mode suggest that the WO + and WOH + interferences on 201 Hg could be reduced effectively (reported concentration of 0.028 μg/l). However, the other four Hg isotopes gave variable results in this mode, indicating that MS/MS is essential for full control of the reaction chemistry. Figure 1. Hg isotopes with and without a W matrix, confirming the complete removal of W-based interferences by ICP-QQQ with MS/MS. Hg in tungsten-rich samples: Hg was measured in a tungsten-rich cosmetic sample using the four different cell gas modes. The five most abundant isotopes of Hg (198, 199, 200, 201, and 202) were used for quantitation, giving five independently calibrated results for Hg. This approach, which is included in several regulated methods across the environmental, food and pharmaceutical industries, is analogous to the use of qualifier ions in organic mass spectrometry. The results are shown in Table 1. Table 1. Hg concentration measured in 100x diluted tungsten-rich cosmetic sample, quantitated independently using five isotopes (μg/l). 198 199 200 201 202 No gas 2670 872 1364 47.7 987 He 1732 577 907 24.6 665 O 2 Single Quad 7.72 2.49 3.99 0.028 2.88 O 2 MS/MS 0.021 0.018 0.024 0.015 0.017 Matrix-based interferences affect different isotopes of an analyte to different degrees, so giving different errors in quantitative results. Comparing the elemental concentrations calculated from different isotopes of an element is a useful approach to identify whether the reported concentration was affected by any interferences. The Hg concentrations measured in MS/ MS mode with O 2 (around 0.02 μg/l for all five isotopes) are much lower and more consistent than the results measured using the other cell gas modes. The good agreement between the results obtained for the five Spike recovery test: A spike recovery test was performed with a 30 ppt spike of Hg being added to the diluted sample. Recovery was 104%, confirming the interference removal capability and matrix tolerance of the method. Conclusions The 8900 ICP-QQQ operating in MS/MS mode with O 2 cell gas is highly effective for the removal of tungsten oxide/ hydroxide polyatomic interferences on the five major Hg isotopes. Using an MS/MS on-mass method with O 2 reaction cell gas, Hg was measured accurately and consistently at trace levels in the presence of W. Compared to conventional single quadrupole ICP- MS, ICP-MS/MS reduced interferences by more than two orders of magnitude. The 8900 ICP-MS/MS method easily meets the requirements of trace level Hg analysis in tungstenrich cosmetic samples. References 1. Federal Food, Drug, and Cosmetic Act (FD&C Act), accessed December 2017, https://www.fda.gov/ Cosmetics/GuidanceRegulation/LawsRegulations/ ucm2005209.htm 2. N. Sugiyama and G. Woods, Agilent publication, 2012, 5991-0892EN. 3. J. Song, X. Zeng, D. Yan and W. Wu, Agilent publication, 2015, 5991-5400EN. 4. L. Balcaen, E. Bolea-Fernandez, M. Resano, F. Vanhaecke, Anal. Chim. Acta, 2015, 894, 7 19. 6

February 2018, Issue 71 Agilent ICP-MS Journal Japan Hosts Another Successful Asia-Pacific Winter Plasma Conference Sayuri Otaki, Global Marketing Manager ICP-MS, Agilent Technologies International Japan Introduction The first Asia-Pacific Winter Conference on Plasma Spectrochemistry (APWC) was held in Thailand in 2005. Since then, the event has also been held in Japan, China, and Korea. The APWC returned to Japan in November 2017, where more than 210 attendees from around the world gathered in the historic coastal city of Matsue for the seventh APWC. The major topics discussed at the conference reflect the wider trends in the developments of plasma spectrochemistry. These topics including single nanoparticle and single cell analysis, laser ablation, isotope ratio and isotope dilution, and speciation were covered in the general sessions and the five plenary lectures delivered by leading international researchers Gary Hieftje. Ryszard Lobinski, Jörg Feldmann, Marcel Burger, and Frank Vanhaecke. Agilent's Contribution - A Team Effort Agilent s ICP-MS product line is based in Tokyo a short flight away from Matsue. Given the proximity, Agilent was well represented at the conference with an experienced team in attendance from Japan, plus field representatives from other Asian countries. Hot Topic: Single Nanoparticle (SNP) Analysis Agilent s luncheon seminar on Single Nanoparticle (SNP) analysis attracted over 100 attendees, highlighting the wide interest in SNP analysis from researchers and industry. Why MS/MS? Explaining the unique benefits In an oral presentation, Senior Agilent Applications Chemist, Michiko Yamanaka, presented a technical and performance comparison of MS/MS vs Bandpass MS. The talk illustrated how MS/MS gives improved control of reaction chemistry. Poster Review A review of the 90 poster presentations showed that more than 25% of the posters related to environmental applications. Materials analysis and clinical/life science research is also a large and growing segment for ICP-MS. The review also showed that Agilent ICP-MS and ICP-QQQ systems were used in more than half of the posters. Agilent's Michiko Yamanaka presenting at the APWC. Details of the next APWC will be available soon. 7

On-Demand Webinars The application of ICP-MS for the characterization of single nanoparticles in biological and environmental water samples This webinar discusses the use of single-particle (sp-) ICP-MS as an emerging analytical technique for the measurement of nanoparticles. Includes sample preparation, method optimization, and data interpretation. Presenter: Arturo Keller, Professor of Biogeochemistry, University of California, Santa Barbara, USA spectroscopynow: Register for on-demand How does ICP-MS improve productivity and profitability in the environmental laboratory? This presentation examines practical ways to configure ICP-MS for the analysis of the wide variety of matrices typically encountered during routine operation at an environmental testing laboratory. Techniques for ensuring calibration stability and effective control of interferences are discussed. Presenter: Richard Burrows, Corporate Technical Director, TestAmerica, USA spectroscopynow: Register for on-demand Agilent ICP-MS Publications To view and download the latest ICP-MS literature, go to www.agilent.com/chem/icpms Application note: Simultaneous Total and Speciation Analysis of Volatile Arsenic Compounds in Gas and Liquefied Gas Samples using GC-ICP-MS, 5991-8799EN Application note: Direct Analysis of Trace Metal Impurities in High Purity Nitric Acid using ICP-QQQ, 5991-8798EN Application note: Multielement Analysis and Selenium Speciation in Cattle and Fish Feed using LC-ICP-QQQ, 5991-9015EN Application note: Absolute Quantification of Proteins in Snake Venom Using caplc-icp-qqq and Online Isotope Dilution Analysis, 5991-9016EN For Research Use Only. Not for use in diagnostic procedures. This information is subject to change without notice. Agilent Technologies, Inc. 2018 Published in the USA, February 14, 2018 5991-8993EN