TB-2012M BAROMETRIC PRESSURE SENSOR USER S MANUAL

Similar documents
Applications. Remote Weather Station with Telephone Communications. Tripod Tower Weather Station with 4-20 ma Outputs

NOVALYNX CORPORATION MODEL 110-WS-16BP BAROMETRIC PRESSURE SENSOR INSTRUCTION MANUAL

PTA-427 BAROMETRIC PRESSURE TRANSDUCER OPERATOR S MANUAL

MKIII -MB USER S GUIDE 09/18/18. Rev. 3

MODEL 107 TEMPERATURE PROBE INSTRUCTION MANUAL

MET ONE RAIN GAGE MODELS 380, 385, 380M, 385M

Fischer 1508BTH-45 5" Brass Barometer with Temperature & Humidity User Manual

Fischer Instruments Chrome and Black Wood Base Weather Station with Barometer, Hygrometer, Thermometer and Quartz Clock User Manual

Fischer Banjo Weather Station with Thermometer, Hygrometer, Barometer User Manual

Ambient Weather WS-152B 6" Contemporary Barometer User Manual

Field Pro Operation and Installation Manual

Weather Stations. Evaluation copy. 9. Post live weather data on the school s web site for students, faculty and community.

Fischer Instruments Stainless Steel Barometer User Manual

SkyScan EWS-PRO - Manual -

WS-7047TWC Wireless 433 MHz Weather Station With Rainfall and Temperature. Instruction Manual

O P E R A T I N G M A N U A L

SP-LITE SILICON PYRANOMETER INSTRUCTION MANUAL

MODEL HMP45C TEMPERATURE AND RELATIVE HUMIDITY PROBE INSTRUCTION MANUAL

Ambient Weather WS-228TBH 9" Brushed Aluminum Traditional Barometer with Temperature and Humidity, Radiant Blue User Manual

WeatherHawk Weather Station Protocol

Ambient Weather DHR70B-BRASS Handheld Fishing Barometer User Manual

3WHB10K 3-WIRE HALF BRIDGE TERMINAL INPUT MODULE INSTRUCTION MANUAL

WS-7211U Wireless 433 MHz Weather Station. Instruction Manual

Model 3024 Albedometer. User s Manual 1165 NATIONAL DRIVE SACRAMENTO, CALIFORNIA WWW. ALLWEATHERINC. COM

product manual H-3220A Benkelman Beam

SKELESCOPE REFLECTOR TELESCOPE WITH TABLE TOP TRIPOD SK-100 INSTRUCTION MANUAL

CM3 PYRANOMETER INSTRUCTION MANUAL

Instruction Manual. Solar Weather Centre With Wireless Weather Vane. Product Code: WS5056C. Solar Powered Outdoor Weather Data Collector

IRTS-P PRECISION INFRARED TEMPERATURE SENSOR INSTRUCTION MANUAL

QUICK SET UP MANUAL WEATHER CENTER

User s Manual: MODEL 904-T CLINOMETER PAK

Meteorological Service

WS-7213U Wireless 433 MHz Weather Station Instruction Manual TABLE OF CONTENTS. Figure 2. Figure 1

LUDLUM MODEL 42-5 NEUTRON BALL CART. August 2015 Serial Number PR and Succeeding Serial Numbers

WS-9018U Wireless Weather Station. Instruction Manual

CR10TCR THERMOCOUPLE REFERENCE

PAM-Station Land-Owner Information Guide Project: CuPIDO, Tucson AZ, Jul/Aug 2006

WARRANTY AND ASSISTANCE

CR10XTCR THERMOCOUPLE REFERENCE

WEATHER STATION FOR SOLAR FARM MONITORING

iweathar EDGE V Installation Guide Copyright 2012 iweathar. All rights reserved.

CR10XTCR THERMOCOUPLE REFERENCE

Model: WT-3181PL Instruction Manual DC: Indoor/Outdoor Atomic Wall Clock. Get Started

Ambient Weather WS-GL026 Porthole Collection Weather Center with Thermometer, Hygrometer, Barometer User Manual

Operating Instructions Validation Tool Kit, KT2 For use with USP Apparatus #1 & #2

INSTRUCTION MANUAL. Laser Diode Sarcomere Length. Aurora Scientific Inc. 360 Industrial Parkway South, Unit 4 Aurora, Ontario, Canada L4G 3V7

LP PYRA Installation and Mounting of the Pyranometer for the Measurement of Global Radiation:

566/568. Infrared Thermometers. Getting Started

PLOW MOUNT KIT FOR POLARIS RANGER P/N ASSEMBLY / OWNERS MANUAL

A Rain Sensitive House Window Closes Automatically When Raining

Rain Watch TM Set up Manual. IC System with Rain Bird IC CONNECT

Directions for use

technical bulletin Installation Instructions: Wall-Mount Dewpoint Probe ( )

MODEL H3022 MAGNETIC BASE / DIAL INDICATOR / CALIPER COMBO OWNER'S MANUAL

A TEST OF THE PRECIPITATION AMOUNT AND INTENSITY MEASUREMENTS WITH THE OTT PLUVIO

Wireless Weather Station. Instruction Manual

PLOW MOUNT KIT FOR YAMAHA VIKING P/N ASSEMBLY / OWNERS MANUAL. Application PLOW PUSH FRAME NO or

CONTENTS. La Crosse Technology, Ltd. Page 1

Centralized Forecasting Registration and Communication Requirements for Distribution Connected Variable Generators. IESO Training

Mini Environmental Quality Meter

Army Air Forces Specification 7 December 1945 EQUIPMENT: GENERAL SPECIFICATION FOR ENVIRONMENTAL TEST OF

Barograph 1.080x

Amplified Pyranometer SP-212 & 215

What is the maximum distance I can have the remote sensors from the display?

Owner's Manual NSL100B BUILDERS LEVEL NSL500B TRANSIT LEVEL

WeatherHub2 Quick Start Guide

Quick Start Guide New Mountain Visit our Website to Register Your Copy (weatherview32.com)

IF YOU NEED ANY FURTHER HELP WITH YOUR GALILEO TELESCOPE PLEASE CALL MON-FRI 9AM - 5PM E.S.COM

INSTRUCTION MANUAL. SP Lite2 Pyranometer. August Copyright 2017 Campbell Scientific (Canada) Corp.

Congratulations on purchasing this WS1516IT Professional Weather Station.

Today s Weather 24 Hour Forecaster

Low Pressure Sensor Amplified Analog Output SM6295-BCM-S

400 Volts, 50HZ 480 Volts, 60HZ 600 Volts, 60HZ TECHNICAL REFERENCE MANUAL

FOR POLARIS ATV s P/N ASSEMBLY / OWNERS MANUAL

1 YEAR LIMITED WARRANTY TELESCOPES

Technical Data Sheet DPT & DPIT-4005 SERIES DIFFERENTIAL PRESSURE TRANSDUCERS. Features. Description

OASIS WIRELESS WEATHER STATION

Small Absolute Pressure Sensor

DRIFTER PLOW-IN-A-BOX

Heat stress index. Dewpoint. pressure. altitude

INSTRUCTION MANUAL ANALOG COLORIMETER

FOR CAN-AM ATV s P/N ASSEMBLY / OWNERS MANUAL

CAUTION: BEFORE YOU BEGIN, ALWAYS MAKE SURE THE WEAPON IS UNLOADED AND SAFE TO HANDLE.

Hadrons Desktop U.S. Atomic Clock & Weather Station

Standard Practices for Air Speed Calibration Testing

Wireless Weather Station Instruction Manual

Weather Monitoring Station Features Easy Wireless Installation and Solar Power

PUSH TUBE STANDARD DUTY

473 Dew Point Hygrometer

Kestrel 4500 Pocket Weather Tracker

STANDARD OPERATING PROCEDURES

NOVALYNX CORPORATION ELEVATION CORRECTION TABLES FOR BAROMETRIC PRESSURE SENSORS

SENSOR PLACEMENT FOR SNOW & ICE MELT APPLICATIONS

SENSORS CLIMATRONICS CORPORATION (631) MANUAL TACMET II WEATHER STATION, EMI 2.0 INSTALLATION 1.0 INTRODUCTION

CASSINI CQR-120 OPERATING INSTRUCTIONS

Engineering Specification

LUDLUM MODEL NEUTRON DETECTOR. December 2017

Protective Coatings: Non-lead orange paint RAL red (optional) non-lead paint Hot dipped galvanized conforming to ASTM A-153.

2. Usually, the air pressure inside a building is the air pressure outside the building. a. greater than b. about the same as c.

Assembly Instructions for the 1-Wire Weather Station V2.0/V3.0

Transcription:

TB-2012M BAROMETRIC PRESSURE SENSOR USER S MANUAL TEXAS ELECTRONICS, INC. 5529 Redfield St. Dallas, TX 75235 P.O. Box 7225 Dallas, TX 75209 Phone (214) 631-2490 Fax (214) 631-4218 Toll Free (800) 424-5651

MICRO SWITCH USA Texas Electronics, Inc. U1 P1 P2 5529 Redfield St. Dallas, Tx 75235 Model TB-2012M Barometer Remove cover of TB-2012M and adjust for local pressure. Refer to Pressure vs Voltage/Current Table under the Barometer section of the service manual. SIG. COM. TB1 +12V COM. D3 D2 R21 D4 D1 C3 R11 R12 R8 R9 R13 R14 R16 C98 C7 C1 U2 C99 C5 C4 R3 R4 R2 R1 R18 R19 R20 R17 R22 REF ELECTRIC BAROMETER MODEL NO. TB-2012M S/N 102795 C6 U3 C2 R15 SPAN NULL MODEL TB-2012M BAROMETRIC PRESSURE SENSOR (Shown with cover removed) DESCRIPTION The Texas Electronics, Inc. TB-2012M Barometric Pressure Sensor uses an active solid-state device to sense barometric pressure. Self-contained electronics provide a regulated voltage to the solid-state sensor and amplification for the signal output. The unit's range of 26" to 32" or 878 mb to 1080 mb of mercury allows it to be used at elevations up to 1800 feet or 548.64 meters above sea level. The unit is temperature compensated from -18 to +50 C. if elevations above 1800 feet or 548.64 meters are required, contact the factory for higher elevation calibration. SPECIFICATIONS Calibration Range: Supply Voltage: Current Draw: Accuracy: Operating Temperature Range: Calibrated Temperature Range: Output: Optional Output: Weight: Dimensions: Warranty: 26" to 32" or 878 mb to 1080 mb 12 to 15 VDC <15 ma +/- 1.3mb -40 to +50 C -18 to +50 C 0-1 VDC 4-20 ma 2 lb. or 8.9 N or.907 kg. w/ 60 ft. or 18.3 meters cable 6" or 15.24 cm H x 5" or 12.7 cm W x 3" or 7.62 cm D (Single enclosure: double enclosure also available) 3 year

FEATURES & BENEFITS Interfaces to virtually all data acquisition systems Can be used up to 1800 ft. elevation without factory modification Over 1800 ft. elevation applications available Easy installation and maintenance Over 5 years in production Weatherproof Nema Enclosure for superior outdoor protection Wide range of 26" to 32" Hg. or 878 to 1080 mb INSTALLATION & MAINTENANCE Select a site where the instrument will not be subject to rapid fluctuations of temperature or to jarring and continuous vibration. Avoid exposing the instrument to direct sunlight or radiant heaters and to direct drafts such as open windows and doors. A mounting bracket with hardware is attached to the Nema enclosure of the sensor. ORDERING INFORMATION Model # TB-2012M TB-2012MA Description Barometric Pressure Sensor Barometric Pressure Sensor, 4-20 ma Optional Parts / Accessories Cable High Elevation: Additional Cable Applications of higher than 1800 ft. or 548.64 meters above sea-level require factory modification.

PROPER EXPOSURE OF METEOROLOGICAL INSTRUMENTS Generally recognized guidelines follow which depict "ideal" sensor mounting locations. These guidelines or "rules of thumb" are only suggestive in nature in an attempt to aid the user to selecting optimum representative sampling locations for a particular sensor. Reference was made to US Weather Bureau Installation criteria in preparing this data (See Reference 1). WIND EQUIPMENT: So far as available sites permit, wind sensors should be placed above the ground on a freely-exposed tower (20 feet or higher) and over terrain that is relatively level and free from obstructions to wind flow. When a compromise must be made, sensing units should be exposed at least 12 feet above any obstruction within 100 feet and at least as high as any obstruction within 100 to 200 feet of the wind equipment. Support towers or masts should not be of such bulk or shape as to create an appreciable obstruction to wind flow. Avoid sites where local obstructions may create up-or-down drafts, eddy currents or jet-flow effects. When sensors are roof-mounted, they should be installed at least 10 feet (or greater) from the roof surface depending upon the particular installation site. Turbulence and other local effects can be reduced somewhat by mounting sensors on the upwind and of the building (that end of the building exposed to the most common local prevailing winds). Horizontal-mount booms which extend from existing towers should be fabricated so that sensors will extend a distance of 5 to 10 feet from the tower assembly (dependent on tower thickness). Wind direction sensors are oriented upon installation in reference to either true north or magnetic north. True north is obtained by applying a local magnetic variation correction factor to a magnetic north compass indication (magnetic variation for a particular locality is obtainable from the nearest Weather Bureau Branch Office). Indicator readings for a true north sensor orientation will then be in terms of true geographic compass points. All U.S. Weather Bureau surface wind data used for observational network reporting purposes and general public use is given in reference to this true north format. Indicator readings for a magnetic north sensor orientation will be in terms of actual readings as would be obtained from directly viewing a magnetic compass instrument. Wind direction data at Federal Aviation Agency and other aircraft reporting facilities (for direct control tower-to-pilot utilization) is always made in reference to this magnetic north format. REMOTE TEMPERATURE/HUMIDITY SENSORS AND INSTRUMENT SHELTERS: Whenever possible, instrument shelters * as well as remote temperature and/or humidity sensors should be installed at a height of 4 feet (or greater) over earth or sod at least 100 feet from any concrete or other hardsurfaced area and not closer to any other object than four times the height of the object above the instrument shelter or remote sensors. Avoid roof installations if possible. If it is necessary to roof-mount shelters and sensors, they should not be closer than 30 feet to any large, vertical reflecting surface (walls, etc.), exhaust fans, or cooling towers. Electronic remote sensors when roof-mounted should be at least 9 feet (or greater) above the roof surface. To minimize radiation effects from the roof, they can also be mounted on a horizontal boom so that they will extend from the side of a building roof or existing tower. Horizontal booms should extend approximately 5 to 10 feet from the side of the building roof or tower assembly. PRECIPITATION GAUGES: Rain gauges should be installed on a level plot of ground, at a distance from any object of at least two and preferably four times the height of the object above the top of the gauge. All types of gauges must be exposed with the rim of the receiver in a horizontal plane and at a level well above the average level of snow surfaces. * Standard U.S. Weather Bureau cotton-region shelter (Spec. No. 450.0615, Rev. 8/67)

Roof-mounting of rain gauges should be avoided when possible. Air currents at heights other than at ground level have been observed to cause an apparent decrease in rainfall catch commensurate with the increase in mounting height above ground level. Objects which individually or in small groups constitute a "windbreak" reduce prevailing wind speed in the vicinity of the gauge. This reduction of wind speed will, as a consequence, also reduce possible eddy currents and turbulence around the gauge. The presence of such objects is usually beneficial in providing a more accurate rainfall catch. Ideally, the "windbreak" objects (fences, bushes, etc.) should be generally uniform in height and distance from the gauge. Height above the gauge should not exceed about twice their distance from the gauge. ANEROID BAROMETERS - SELF-CONTAINED MECHANICAL INSTRUMENTS AND ELECTRONIC REMOTE BAROMETRIC PRESSURE SENSORS: Select a site where the instrument will not be subject to rapid fluctuations of temperature or to jarring and continuous vibration. Avoid exposing the instrument to direct sunlight or radiant heaters and to direct drafts such as open windows and doors. Reference 1: U.S. Department of Commerce - National Weather Service Bulletin LS 5927 Revised, 0-4.12, January, 1963. SOLAR RADIATION SENSORS: The Solar Radiation Sensor is normally mounted on a level surface totally remote from trees, poles, or power lines that might cast a shadow on the sensor at any time of the day. However, there may be occasions, because of extreme latitudes, when it is desired to mount the sensor at some angle other than level. The sensors may also be mounted on a sun tracking mechanism or behind a shadow band if diffuse sky radiation is to be measured.

TB-2012M ALTITUDE SETTING INSTRUCTIONS To set barometer to your elevation, follow the instructions listed below: Output: 0-1V Range: 26 to 32.1666V/Inch.001666V/.01 Inch Obtain local barometric pressure from NOAA, NWS, airport, radio/tv station, or from any facility that would have the most accurate information closest to your installation. If you are using the Texas Electronics, Inc. digital or analog indicators, remove the four cover screws from the TB-2012M and adjust the null pot (R15) until your indicators agree with the reference obtained. You may want to do this more than once, especially if the weather is unsettled at the time. If you are connected to a Solus Data logger you can set to your elevation by inserting either a plus or minus voltage in the [calibrate] Offset : xxxx box. With Solus running follow these steps: from menu bar, click on setup, sensor, edit, select TB-2012M then insert value desired then save,.10 increases reading by.10 -.10 decreases reading by.10 By using the chart below and the following conversion, it is very easy to set up. Example: If the pressure reading that you obtained is 29.13 : From the chart below: Choose 29, which is.500 V. Then multiply, 13 x.00166 V. =.0216 V..5 V. +.0216 V. =.52160 V. should be the proper output. Set null pot (R15) until that voltage output is obtained. 26 =.00 V. 27 =.166V. 28 =.333V. 29 =.500V. 30 =.666V. 31 =.833V. 32 = 1.000V. NOTICE! IF THE FINAL OUTPUT FROM THE OVERALL SYSTEM IS OTHER THAN 0-1 VOLT, THERE WILL BE A PA-03-1 AMPLIFIER INSTALLED IN THE ELECTRONICS PACKAGE SUCH AS THE BPC-250 OR BPC-500. THE OUTPUT FROM THE TB-2012M IS FED DIRECTLY INTO THE PA- 03-1 AND AMPLIFIED TO THE USERS NEEDS. BE SURE TO TAKE THIS INTO CONSIDERATION WHEN SETTING UP THE SYSTEM AT IT S PERMANENT ELEVATION. Replace cover and secure evenly. System should not need further calibration or setup.

Altitude (feet) R14 2500-9500 44.2k 9500-13500 61.9k 13500-15500 75.0k 17500-20500 1 1 0 K ( R 1 5 = 5 0 K) Max imum Altitude is 20500 Feet Standard Output Is 0-1 Volt (166Mv./In.) Altitude: 0-2500 Feet Range: 26" to 32" Hg For Altitude above 2500 feet See Chart Above For 0-2.5 Volt Output R14=50K R15=5K R16=95.5K R17=50K For 0-3 Volt Output R14=50K R15=20K R16=120K R17=10K For 0-5 Volt Output R14=64.9K R15=20K R16=191K R17=50K POT

Warranty Texas Electronics, Inc. (hereafter TEI) warrants the equipment manufactured by it to be free from defects in material and workmanship. Upon return, transportation charges prepaid to TEI, within three (3) years of original shipment of sensors and one (1) year of original shipment of electronics, recorders and indicators, TEI will repair or replace, at its option, any equipment which it determines to contain defective material or workmanship, and will return said equipment to purchaser, F.O.B., TEI. Texas Electronics shall not be obligated however to repair or replace equipment which has been repaired by others, abused, improperly installed, altered or otherwise misused or damaged in any way. TEI will not be responsible for any dismantling, re-assembly, or reinstallation charges. This warranty is in lieu of all other warranties, expressed or implied. TEI shall not be liable for any special, indirect, incidental or consequential damages claimed in connection with any rescission of this agreement by purchaser. For a list of specific items covered by the extended warranty, see the Three-Year Warranty Equipment List.

Three-Year Warranty Equipment List Effective February 1, 1992 all of Texas Electronics, Inc. sensors will carry a Three-Year warranty instead of the previous One-Year. The remainder of terms and conditions of the warranty remains unchanged. A specific list of items follows. Sensors Covered by Three-Year Warranty Parameter Wind Direction Wind Speed Barometric Pressure Relative Humidity Rainfall Temperature Solar Radiation Model No. TD-105 (Synchro) TD-104D (Potentiometer) TD-110-L2 (Photo-Chopper) TD-106 (Potentiometer) TV-110-L2 (Photo-Chopper) TV-110-L3 (Photo-Chopper) TV-114 (A.C. Generator) TB-2012 TH-2013 TH-2013V TR-525 TR-6118 TT-101 (Outdoor) TT-103R (Surface Mount) TT-103R-W (Water Probe) TT-309I (Indoor) TS-100 Systems Covered by Three-Year Warranty Model No. WSC-5-S WSC-5-ST WSC-5-D WSC-5-DT WDC-2 Description Wind Speed Controller Single Set Point Wind Speed Controller Single Set Point with Time Delay Wind Speed Controller Dual Set Point Wind Speed Controller Dual Set Point with Time Delay Wind Direction Controller