Characteristic X-rays of molybdenum

Similar documents
This experiment is included in the XRP 4.0 X-ray solid state, XRS 4.0 X-ray structural analysis, and XRC 4.0 X-ray characteristics upgrade sets.

Absorption of X-rays

TEP Examination of the structure of NaCl monocrystals with different orientations

Determination of the Rydberg constant, Moseley s law, and screening constant (Item No.: P )

Physical structure of matter. Duane-Hunt displacement law and Planck's quantum of action X-ray Physics. What you need:

Physical Structure of Matter. K a doublet splitting of molybdenum X-rays / fine structure Physics of the Electron.

TEP K and L edge absorption Moseley s law and the Rydberg constant

X-ray fluorescence analysis - calibration of the X-ray energy detector

X-ray absorption. 4. Prove that / = f(z 3.12 ) applies.

Atomic and nuclear physics

Atomic and nuclear physics

Bragg reflection :determining the lattice constants of monocrystals

X-RAY SPECTRA. Theory:

Lab Manual: Determination of Planck s constant with x-rays

CASSY Lab. Manual ( )

X-ray Absorption Spectroscopy

X-ray spectroscopy: Experimental studies of Moseley s law (K-line x-ray fluorescence) and x-ray material s composition determination

X-ray Spectroscopy. Danny Bennett and Maeve Madigan. October 12, 2015

Caution! Pay close attention to the special operation and safety instructions in the manual of the ultrasonic echoscope.

Alpha-Energies of different sources with Multi Channel Analyzer

X-ray Spectroscopy. c David-Alexander Robinson & Pádraig Ó Conbhuí. 14th March 2011

Magnetic field of single coils/ Biot-Savart s law with Cobra4

Physical Structure of Matter

X-ray practical: Crystallography

LAB 01 X-RAY EMISSION & ABSORPTION

Newton s 2nd Law with demonstration track and Cobra4

Shear waves in solid-state materials

Atomic and nuclear physics

X-Rays Edited 2/19/18 by DGH & Stephen Albright

Andrew D. Kent. 1 Introduction. p 1

Solid-state physics. Laue diagrams: investigating the lattice structure of monocrystals. LEYBOLD Physics Leaflets P

Atomic and Nuclear Physics

Alpha-energies of different sources with Multi Channel Analyzer (Item No.: P )

Chemistry Instrumental Analysis Lecture 19 Chapter 12. Chem 4631

X-rays. X-ray Radiography - absorption is a function of Z and density. X-ray crystallography. X-ray spectrometry

Physical Structure of Matter Hall effect in p-germanium with Cobra3. Solid-state Physics, Plasma Physics.

print first name print last name print student id grade

Elementary charge and Millikan experiment Students worksheet

UNIVERSITY OF SURREY DEPARTMENT OF PHYSICS. Level 1: Experiment 2F THE ABSORPTION, DIFFRACTION AND EMISSION OF X- RAY RADIATION

β-spectroscopy Fig. 1: Experimental set-up for determining inductance from the resonant frequency of an oscillatory circuit.

X-Ray Emission and Absorption

Titration of a strong acid with a strong base with Cobra4

Crystal Structure and Electron Diffraction

Related topics Velocity, acceleration, force, gravitational acceleration, kinetic energy, and potential energy

Relaxation times in nuclear magnetic resonance

Related concepts Electrolyte, electrical conductance, specific conductance, ion mobility, ion conductivity, conductometry, volumetry.

LEP Hall effect in p-germanium with Cobra3

Capacitor in the AC circuit with Cobra3

Jazan University College of Science Physics Department. Lab Manual. Nuclear Physics (2) 462 Phys. 8 th Level. Academic Year: 1439/1440

Physical structure of matter Band gap of germanium with Cobra3. Solid-state Physics, Plasma Physics. What you need:

Röntgenpraktikum. M. Oehzelt. (based on the diploma thesis of T. Haber [1])

Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy. Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy

Planck's "quantum of action" and external photoelectric effect (Item No.: P )

Thermal expansion of liquids

Moment and angular momentum

Laboratory Manual 1.0.6

Nanoscale work function measurements by Scanning Tunneling Spectroscopy

Revision Guide. Chapter 7 Quantum Behaviour

Conservation of momentum in a central elastic collision with the demonstration track and timer 4 4

Coherence and width of spectral lines with Michelson interferometer

Centripetal and centrifugal force

STUDENT EXPERIMENTS PHYSICS, CHEMISTRY & BIOLOGY

Chapter 10: Wave Properties of Particles

Photoelectric effect

Surface Sensitivity & Surface Specificity

Particles and Waves Particles Waves

Experiment 9. Emission Spectra. measure the emission spectrum of a source of light using the digital spectrometer.

Practical 1P4 Energy Levels and Band Gaps

X-RAY SCATTERING AND MOSELEY S LAW. OBJECTIVE: To investigate Moseley s law using X-ray absorption and to observe X- ray scattering.

V 11: Electron Diffraction

203-NYC-05: Waves, Optics & Modern Physics

Forced oscillation - Pohl s pendulum with measure Dynamics. Equipment TEP

FXA UNIT G485 Module X-Rays. Candidates should be able to : I = I 0 e -μx

Setting The motor that rotates the sample about an axis normal to the diffraction plane is called (or ).

The University of Hong Kong Department of Physics

!!!!! General!Physics!I!&!II!Lab!!! Course!Description!! Lab!Report!Template!and!Sample!! Grading!Rubrics! Pre>Lab!Quizzes!!!!!!!!

Chapter 30 X Rays GOALS. When you have mastered the material in this chapter, you will be able to:

1240 ev nm nm. f < f 0 (5)

Automated Determination of Crystal Reflectivity in the X-ray Laboratory

A Determination of Planck s Constant with LED s written by Mark Langella

DAY LABORATORY EXERCISE: SPECTROSCOPY

SCINTILLATION DETECTORS & GAMMA SPECTROSCOPY: AN INTRODUCTION

Diffraction: spreading of waves around obstacles (EM waves, matter, or sound) Interference: the interaction of waves


Coulomb s law with Cobra3

Practical 1P4 Energy Levels and Band Gaps

4.1b - Cavity Theory Lecture 2 Peter R Al mond 2011 Overview of Lecture Exposure (W/e)air Exposure Exposure and and and Air Air Kerma

XRF books: Analytical Chemistry, Kellner/Mermet/Otto/etc. 3 rd year XRF Spectroscopy Dr. Alan Ryder (R222, Physical Chemistry) 2 lectures:

Chapter Six: X-Rays. 6.1 Discovery of X-rays

SEM. Chemical Analysis in the. Elastic and Inelastic scattering. Chemical analysis in the SEM. Chemical analysis in the SEM

Rutherford experiment with MCA

1 Photoelectric effect - Classical treatment. 2 Photoelectric effect - Quantum treatment

Uniformly accelerated motion with an accelerating mass with the demonstration track and timer 4 4

hν' Φ e - Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous?

Nanoscale characteristics by Scanning Tunneling Spectroscopy

PHYS 3650L - Modern Physics Laboratory

Spectrometer User s Guide

High-Resolution. Transmission. Electron Microscopy

Beamline practice at BL01B1 (XAFS) In-situ XAFS measurement of catalyst samples

Experiment 6 1. The Compton Effect Physics 2150 Experiment No. 6 University of Colorado

Transcription:

Characteristic X-rays of molybdenum TEP Related Topics X-ray tubes, bremsstrahlung, characteristic X-radiation, energy levels, crystal structures, lattice constant, absorption of X-rays, absorption edges, interference, and Bragg s law Principle An X-ray tube with a molybdenum anode generates X-radiation that is selected with the aid of a monocrystal as a function of the Bragg angle. A Geiger-Müller counter tube measures the intensity of the radiation. The glancing angles of the characteristic X-ray lines are then used to determine the energy. Equipment 1 XR 4.0 expert unit 09057-99 1 X-ray goniometer 09057-10 1 X-ray plug-in unit with a Mo X-ray tube 09057-60 1 Counter tube, type B 09005-00 1 X-ray lithium fluoride crystal, mounted in a holder 09056-05 1 X-ray potassium bromide crystal, mounted in a holder 09056 1 X-ray diaphragm tube, d = 1 mm 09057 1 measure XRm 4.0 X-ray software 14414-61 1 Data cable USB, plug type A/B 14608-00 Additional equipment PC, Windows XP or higher This experiment is included in the upgrade set XRC 4.0 X-ray characteristics. Fig. 1: XR 4.0 expert unit 09057-99 www.phywe.com P2540201 PHYWE Systeme GmbH & Co. KG All rights reserved 1

TEP Characteristic X-rays of molybdenum Tasks 1. Analyse the intensity of the molybdenum X-radiation as a function of the Bragg angle and with the aid of a LiF monocrystal. 2. Repeat task 1 with a KBr monocrystal as the analyser. 3. Determine the energy values of the characteristic X-rays of molybdenum based on the spectra and compare them with the values that were determined based on the corresponding energy-level diagram. Set-up Connect the goniometer and the Geiger-Müller counter tube to their respective sockets in the experiment chamber (see the red markings in Fig. 2). The goniometer block with the analyser crystal should be located at the end position on the right-hand side. Fasten the Geiger-Müller counter tube with its holder to the back stop of the guide rails. Do not forget to install the diaphragm in front of the counter tube (see Fig. 3). Insert a diaphragm tube with a diameter of 2 mm into the beam outlet of the tube plug-in unit for the collimation of the X-ray beam. Note Details concerning the operation of the X-ray unit and goniometer as well as information on how to handle the monocrystals can be found in the respective operating instructions. Fig. 2: Connectors in the experiment chamber GMcounter tu- Goniometer at the end positi Diaphragm tu- Counter tube diaphragm Mounted crystal Fig. 3: Set-up of the goniometer 2 PHYWE Systeme GmbH & Co. KG All rights reserved P2540201

Characteristic X-rays of molybdenum TEP Procedure Fig. 4: Connection of the computer - Connect the X-ray unit via USB cable to the USB port of your computer (the correct port of the X-ray unit is marked in Fig. 4). - Start the measure program. A virtual X-ray unit will be displayed on the screen. - You can control the X-ray unit by clicking the various features on and under the virtual X-ray unit. Alternatively, you can also change the parameters at the real X-ray unit. The program will automatically adopt the settings. - Click the experiment chamber to change the parameters for the experiment. Select the parameters as shown in Figure 6 for the LiF crystal. If you use the KBr crystal, select a start angle of 3 and a stop angle of 30. - If you click the X-ray tube, you can change the voltage and current of the X-ray tube. Select the parameters as shown in Fig. 7. - Start the measurement by clicking the red circle. - After the measurement, the following window appears: For setting the X-ray tube For setting the goniometer Fig. 5: Part of the user interface of the software - Select the first item and confirm by clicking OK. The measured values will now be transferred directly to the measure software. - At the end of this manual, you will find a brief introduction to the evaluation of the resulting spectra. Note - Never expose the Geiger-Müller counter tube to the primary X-radiation for an extended period of time. Overview of the settings of the goniometer and X-ray unit: - 1:2 coupling mode - Gate time 2 s; angle step width 0.1 - Scanning range 3-65 (LiF monocrystal), and 3-30 (KBr monocrystal) - Anode voltage U A = 35 kv; anode current I A = 1 ma www.phywe.com P2540201 PHYWE Systeme GmbH & Co. KG All rights reserved 3

TEP Characteristic X-rays of molybdenum Fig 6: Settings of the goniometer Fig 7: Voltage and current settings Theory When electrons impinge on the metallic anode of the X-ray tube with a high level of kinetic energy, X- rays with a continuous energy distribution (the so-called bremsstrahlung) are produced. The spectrum of the bremsstrahlung is superimposed by additional discrete lines. If an atom of the anode material is ionised on the K shell following an electron impact, an electron from a higher shell can take up the free place while emitting an X-ray quantum. The energy of this X-ray quantum corresponds to the energy difference of the two shells that are involved in this process. Since this energy difference is atom-specific, the resulting radiation is also called characteristic X-radiation. Fig. 8 shows the energy level diagram of a molybdenum atom. Characteristic X-radiation that is produced following a transition from the L shell to the K shell is called K α radiation, while the radiation that is produced following a transition from the M shell to the K shell is called K β radiation (M 1 K and L 1 K transitions are not allowed due to quantum-mechanical selection rules). The characteristic X-ray lines of molybdenum have the following energy levels (Fig. 8): Fig. 8: Energy-level diagram of molybdenum (Z = 42) 4 PHYWE Systeme GmbH & Co. KG All rights reserved P2540201

Characteristic X-rays of molybdenum TEP 1 E = E K K L2 L3 427 * 2 = α ( E + E ) 17. kev EKβ = EK EM 2,3 = 19. 590keV (1) E Kα* is the energetic mean value of the K α1 and K α2 lines. The analysis of polychromatic X-rays is made possible through the use of a monocrystal. When X- rays of the wavelength λ impinge on the lattice planes of a monocrystal under the glancing angle ϑ, the rays that are reflected on the lattice planes interfere with each other in a constructive manner provided that their path difference Δ corresponds to an integral multiple of the wavelength. In accordance with Figure 9, Bragg s law applies to constructive interference: Fig.9: 2d sinϑ = nλ (d = interplanar spacing; n = 1, 2, 3, ) If the interplanar spacing d is known, the wavelength λ can be determined with the aid of the glancing angle ϑ. The energy of the radiation then results from: E = h f = hc λ When combining (2) and (3), we obtain: E = ( n h c) ( 2d sinϑ) Planck's constant = 6.6256 10 Js Velocity of light c 8 = 2.9979 10 m/s Interplanar spacing LiF (200) d -10 = 2.014 10 m Interplanar spacing KBr (200) d -10 = 3.290 10 m Equivalent 1 ev = 1.6021 10-19 J h -34 Bragg scattering on a pair of lattice planes (2) (3) (4) Note The data of the energy-level diagram were taken from the "Handbook of Chemistry and Physics", CRC Press Inc., Florida. Evaluation In the following section, the evaluation of the data is described based on example results. Your results may differ from the results given below. Task 1: Analyse the intensity of the molybdenum X-radiation as a function of the Bragg angle and with the aid of a LiF monocrystal. Figure 10 shows the X-ray spectrum of molybdenum that was analysed with a LiF monocrystal. Welldefined lines are superimposed on the continuous bremsspectrum. The glancing angles of these lines www.phywe.com P2540201 PHYWE Systeme GmbH & Co. KG All rights reserved 5

TEP Characteristic X-rays of molybdenum remain unaltered when the anode voltage is varied. This indicates that these lines are characteristic X- ray lines. The first three pairs of lines can be assigned to first-, second-, and third-order interferences (n = 1, 2, 3). Due to the decreasing intensity of the spectrum in the direction of larger glancing angles, fourth- and fifth-order interferences are only visible (very faintly) for the K α line. The separation of the K α doublet can already be observed (very faintly) for n = 4 and n = 5 (see also the P2540701 and P2540801 experiments). Fig. 10: Intensity of the X-radiation of molybdenum as a function of the glancing angle ϑ; analyser crystal: LiF Fig. 11: Intensity of the X-radiation of molybdenum as a function of the glancing angle ϑ; analyser crystal :KBr 6 PHYWE Systeme GmbH & Co. KG All rights reserved P2540201

Characteristic X-rays of molybdenum TEP Task 2: Analyse the intensity of the molybdenum X-radiation as a function of the Bragg angle and with the aid of a KBr monocrystal. If the LiF monocrystal is replaced by the KBr monocrystal (Fig. 11), interferences up to the fourth order can be observed. The spectrum of the bremsstrahlung in Figure 11 shows clear intensity steps at ϑ = 8.2 und ϑ = 16.5. They correspond to the K-edge absorption value of bromine (E K = 13.474 kev) with n = 1 or n = 2 that can be expected in theory. The K-edge absorptions of potassium, lithium, and fluorine cannot be observed in this area of the bremsspectrum, since the intensity is too low (for K- and L-edge absorption experiments, please refer to experiment P2541201). Task 3: Determine the energy values of the characteristic X-rays of molybdenum based on the spectra and compare them with the values that were determined based on the corresponding energy-level diagram. Table 1 shows the glancing angles ϑ that were determined with the aid of Figures 10 and 11 and also the energy values for the characteristic X-ray lines of molybdenum that were calculated with the aid of equation (4). Based on the energy values of the characteristic lines of Tasks 1 and 2, the following mean values result: E Kα = 17.244 kev and E Kβ = 19.338 kev. A comparison with the corresponding values of (1) shows good correspondence. Table 1: Results θ/ Line E exp /kev LiF crystal n=1 10.4 Kα 17.100 9.2 K β 19.525 n=2 20.9 Kα 17.244 18.5 K β 19.401 n=3 32.2 Kα 17.324 28.4 K β 19.399 n=4 45.1 Kα 17.390 KBr crystal n=1 6.4 Kα 16.823 5.7 K β 18.942 n=2 12.6 Kα 17.286 11.2 K β 19.425 n=3 19.0 Kα 17.339 n=4 25.6 K α 17.446 Note The evaluation of the two spectra can be varied as follows: Use the energy values of the characteristic lines that were determined for one of the spectra in order to determine the interplanar spacing d of the analyser crystal that was used for the other spectrum with the aid of equation (4). www.phywe.com P2540201 PHYWE Systeme GmbH & Co. KG All rights reserved 7

TEP Characteristic X-rays of molybdenum measure software With the measure software, the peaks in the spectrum can be determined rather easily: Refer to the Help of the measure software for additional, more detailed explana- - Click the button and select the area for the peak determinationtions concerning the program features. - Click the button Peak analysis. - The window Peak analysis appears (see Fig. 12). - Then, click Calculate. - If not all of the desired peaks (or too many of them) are calculated, readjust the error tolerance accordingly. - Select Visualise results in order to display the peak data directly in the spectrum. Fig. 12: Automatic peak analysis with measure 8 PHYWE Systeme GmbH & Co. KG All rights reserved P2540201