International Journal of Pharmaceutical Research & Analysis

Similar documents
Flash Chromatography: Area & Applications

Pure Chromatography Consumables Pure flexibility. Pure specialization. Pure convenience.


Chromatography: Thin-Layer Chromatography (TLC) & Column Chromatography

PRINCIPLES AND APPLICATION OF CHROMATOGRAPHY. Dr. P. Jayachandra Reddy Mpharm PhD Principal & professor KTPC

High Pressure/Performance Liquid Chromatography (HPLC)

Biochemistry. Biochemical Techniques HPLC

Ch.28 HPLC. Basic types of Liquid Chromatography Partition (LLC) Adsorption (LSC) Ion Exchange (IC) Size Exclusion (SEC or Gel Chromatography)

Chromatography & instrumentation in Organic Chemistry

Chromatography. Gas Chromatography

Chapter content. Reference

Sample Preparation TLC Plates

Liquid Chromatography

Utilizing ELSD and MS as Secondary Detectors for Prep HPLC and Flash Chromatography. Tips and Techniques to Optimize ELSD and MS based Purification

Varian Galaxie Chromatography Data System for Preparative HPLC

Chromatography- Separation of mixtures CHEM 212. What is solvent extraction and what is it commonly used for?

Prelab Reading Assignment: Laboratory Techniques in Organic Chemistry, 4 th Ed. Chapter 19

High Performance Liquid Chromatography

High Performance Liquid Chromatography

RediSep Rf C18 Flash Column Loading Techniques

LC Technical Information

Automating Gradient Method Development in Flash Chromatography For Greater Productivity and Minimizing Solvent Use

Biotage 2012 Webinar series

Optimized Flash Chromatography Purification: From TLC to large scale in three steps

High Performance Liquid Chromatography

Physical Separations and Chromatography

Open Column Chromatography, GC, TLC, and HPLC

CHROMATOGRAPHY, AND MASS SPECTRAL. FRACTIONS OF Lasianthus

Liquid storage: Holds the solvent which is going to act as the mobile phase. Pump: Pushes the solvent through to the column at high pressure.

The Low-Temperature Evaporative Light-Scattering Detector (LT-ELSD)

Peptide Isolation Using the Prep 150 LC System

Chemistry Gas Chromatography: Separation of Volatile Organics

For Chromatography, you might want to remember Polar Dissolves More, not like dissolves like.

High Performance Liquid Chromatography

Scott Anderson, Kathy Lawrence Dennis McCreary, Melissa Wilcox. Grace Davison Discovery Sciences

Evaporative Light Scattering Detector (ELSD)

Harris: Quantitative Chemical Analysis, Eight Edition CHAPTER 23: GAS CHROMATOGRAPHY

AUTOMATED CHROMATOGRAPHY SYSTEMS. Featuring EZ Prep

Lab 10 Guide: Column Chromatography (Nov 3 9)

FLASH CHROMATOGRAPHY

Agilent 385-ELSD Evaporative Light Scattering Detector

LC III: HPLC. Originally referred to as High-Pressure Liquid Chromatography. Now more commonly called High Performance Liquid Chromatography

Experiment UPHPLC: Separation and Quantification of Components in Diet Soft Drinks

LC walk-up system using the Agilent 1200 Series LC Method Development Solution and Agilent Easy Access software. Application Note

Disadvantage: Destructive Technique once analyzed by GC, the sample is lost

Agilent 385-ELSD Evaporative Light Scattering Detector

HPLC. High Performance Liquid Chromatography (HPLC) Harris Chapter 25

Chromatography Extraction and purification of Chlorophyll CHM 220

Chemistry Instrumental Analysis Lecture 31. Chem 4631

2501 High Performance Liquid Chromatography

EXPERIMENT #1 SEPARATION AND RECOVERY OF ORGANIC COMPOUNDS, THIN LAYER CHROMATOGRAPHY, COLUMN CHROMATOGRAPHY, CRYSTALLIZATION AND MELTING POINTS

Volumetric Analysis. Quantitative analysis answers the second question

Chromatography Lab # 4

Chromatography. writing in color

Lab.2. Thin layer chromatography

CHROMATOGRAPHY. The term "chromatography" is derived from the original use of this method for separating yellow and green plant pigments.

Some Useful and Practical Tips for! Flash Chromatography! February 14th 2008!

GAS CHROMATOGRAPHY (GC)

MODERN HPLC FOR PRACTICING SCIENTISTS

Basic Principles for Purification Using Supercritical Fluid Chromatography

CHAPTER CHROMATOGRAPHIC METHODS OF SEPARATIONS

Flash chromatography purification of high pka organic compounds with Teledyne Isco s specialty RediSep columns

Instrumental Chemical Analysis

Introduction to Pharmaceutical Chemical Analysis

Gas Chromatography. Introduction

Abstract: An minimalist overview of chromatography for the person who would conduct chromatographic experiments, but not design experiments.

Practical 1 Procedure Iron by Titrimetry

Expediting Achiral SFC Method Development Using a Multi-Channel SFC System with MS Detection

Chromatography and Functional Group Analysis

Chromatography. Chromatography is a combination of two words; * Chromo Meaning color * Graphy representation of something on paper (writing)

CfE Higher Chemistry. Unit 3: Chemistry in Society. Chemical Analysis as part of quality control

Using a mini-gas Chromatograph (GC): Identifying Unknown Compounds

Principles of Gas- Chromatography (GC)

GUIDELINES FOR THE DESIGN OF CHROMATOGRAPHIC ANALYTICAL METHODS INTENDED FOR CIPAC COLLABORATIVE STUDY

Dr. OligoTM DNA / RNA / OLIGO SYNTHESIZERS

Institute for Chemical Education, Fun With Chemistry; Vol. 1, Sarquis, Mickey and Sarquis, Gerry, Ed.; University of Wisconsin Madison, 1991,

Investigation of Petasis and Ugi Reactions in Series in an Automated Microreactor System

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

Chromatographic Methods of Analysis Section 2: Planar Chromatography. Prof. Tarek A. Fayed

NEVIRAPINE ORAL SUSPENSION Final text for addition to The International Pharmacopoeia (February 2009)

Selecting Detectors for Compounds with No Optical Absorbance

Figure 1. Structures for Vitamin B2 and Vitamin B1.

Thin Layer Chromatography

Minimizing Solvent Impact on Purification of Nitrogencontaining

Chem 230, Fall, 2014 Homework Set # 3 Short Answer SOLUTIONS

High Performance Liquid Chromatography (HPLC) of Three Analgesics

separation of the cleaned extract in subgroups of compounds (PCDDs, PCDFs, PCBs) depending on their polarity and geometry. The fractions can then be a

Analytical Chemistry

Agilent 1260 Infinity Evaporative Light Scattering Detector (ELSD)

Application Note. Author. Abstract. Pharmaceutical QA/QC. Siji Joseph Agilent Technologies, Inc. Bangalore, India

Gas Chromatography (GC)! Environmental Organic Chemistry CEE-PUBH Analysis Topic 5

Determination of the Equivalent Weight and the K a or K b for a Weak Acid or Base

HPLC Praktikum Skript

Packings for HPLC. Packings for HPLC

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

Preparative Chromatography with Improved Loadability

Column Liquid Chromatography Experiment Adapted for Use in Secondary Schools

7 INSTRUMENTAL CHROMATOGRAPHY

Course goals: Course goals: Lecture 1 A brief introduction to chromatography. AM Quality parameters and optimization in Chromatography

Spectroscopy and Chromatography

Transcription:

328 International Journal of Pharmaceutical Research & Analysis e-issn: 2249 7781 Print ISSN: 2249 779X www.ijpra.com FLASH CHROMATOGRAPHY AND ITS ADVANCEMENT: AN OVERVIEW E.Mamatha Rani, * K.Shilpa, V.Umamaheswara Rao Dept. of Pharmaceutical Analysis & QA CMR College of Pharmacy, Hyderabad, Andhra Pradesh, India. ABSTRACT Flash chromatography is widely used for purification of low molecular weight natural compounds and products of organic synthetic reactions. Modern flash techniques include the use of convenient disposable flash cartridges instead of glass columns. Flash purification systems allow users to speed up the purification process for quicker results and higher throughput. In this review, we present the introduction of FC, the principle involved, instrumentation, general procedure and advancement in Flash chromatography along with its applications. Keywords: Flash cartridges, Molecular weight and Modern flash. INTRODUCTION All chromatographic methods with the exception of TLC- use columns for the separation process. Column chromatography has found its place in many laboratories for preparative purposes as well as for reaction control in organic synthesis [1]. The importance of column chromatography is mainly due to following factors like Low expense for instrumentation, Simple packing procedure, Low operating pressures. Column chromatography is separated into two categories, depending on how the solvent flows down the column. If the solvent is allowed to flow down the column by gravity, or percolation, it is called Gravity column chromatography. If the solvent is forced down the column by positive air pressure, it is called Flash chromatography [2]. In traditional column chromatography a sample to be purified is placed on the top of a column containing some solid support, often silica gel. The rest of the column is then filled with a solvent (or mixture of solvents) which then runs through the solid support under the force of gravity. The various components to be separated travel through the column at different rates and then can be collected separately as they emerge from the bottom of the column. Unfortunately, the rate at which the solvent percolates through the column is slow. In flash chromatography however air pressure is used to speed up the flow of Corresponding Author:- E. Mamatha rani solvent, dramatically decreasing the time needed to purify the sample, therefore making the column and running the separation could take less than 10-15 minutes.flash chromatography is basically an air pressure driven hybrid of medium pressure and shorter column chromatography which has been optimized for particularly rapid separation. Flash chromatography is a technique used to separate mixtures of molecules into their individual constituents, frequently used in the drug discovery process. Flash chromatography, also known as medium pressure chromatography, was popularized several years ago by Clark Still of Columbia University, as an alternative to slow and often inefficient gravity-fed chromatography. Flash chromatography differs from the conventional technique as Slightly smaller silica gel particles (250-400 mesh) are used. Due to restricted flow of solvent caused by the small gel particles, pressurized gas (10-15 psi) is used to drive the solvent through the column of stationary phase. The net result is a rapid ( over in a flash ) and high resolution chromatography. Automated flash chromatography systems include components normally found on more expensive HPLC systems such as a gradient pump, sample injection ports, a UV detector and a fraction collector to collect the eluent. Typically these automated systems separate samples from a few milligrams up to an Email:- mamathaelupula@gmail.com

industrial kg scale and offer much cheaper and quicker solution to doing multiple injections on prep-hplc system [3]. The software controlling an automated system coordinate the components, allow a user to only collect the factions that contain their target compound and help the user to find the resulting purified material within the fraction collector. The software also saves the resulting chromatograph from the process for archival and/or later recall purposes. ADVANTAGES Speed in purifying milligrams to grams of material. Typical purity of greater than 90% on a single run. Operation costs lower than HPLC like, Less acquisition cost. Higher sample loading. Less column costs. Minimal method development time. Well packed cartridges ensure better resolution and separation than manual column chromatography. Pressure and flow rates are controlled and optimal for individual runs. Less solvent consumption, shorter purification times due to minimal setup needs. Pure samples are obtained in fewer fractions, more concentrated products requiring less drying. Multiple detection allows non chromophoric components to be easily identified and isolated. PRINCIPLE The principle is that the eluent which is a liquid, under gas pressure (normally nitrogen or compressed air) rapidly pushed through a short glass column. The glass column is packed with an adsorbent of defined particle size with large inner diameter. The most used stationary phase is silica gel 40 63 μm, but obviously packing with other particle sizes can be used as well. Particles smaller than 25 μm should only be used with very low viscosity mobile phases, because otherwise the flow rate would be very low. Normally gel beds are about 15 cm high with working pressures of 1.5 2.0 bars. Originally only unmodified silica was used as the stationary phase, so that only normal phase chromatography was possible. In the meantime, however, and parallel to HPLC, reversed phase materials are used more frequently in flash chromatography [4-6]. INSTRUMENTATION Solvent reservoir Pumps Cartridges Sample injector Detectors Fraction collection trays Display for monitoring Waste collection 329 Solvent reservoir It is used for the storage of solvents. It is located back side of the display. Solvent lines are dipped into the solvent bottles. For each solvent line has solvent sensor to remind when solvent bottle is empty [7]. Pumps It has quaternary pump. It can pump four different solvents at a time. The pumps work on suck and pump principle i.e first it sucks the solvent and then pump [8]. Cartridges Separation of the various components in the sample takes place on the stationary phase. Choice of stationary phases: Silica: slightly acidic medium. Best for ordinary compounds, good separation is achieved(230-400 mesh, 40-63um, is the most commonly used) Florisil: mild, neutral medium. 200 mesh can be effective for easy separation. Alumina: basic or neutral medium. Can be effective for easy separation, and purification of amines Reverse phase silica: best for highly polar compounds. The most polar compounds elute faster than the non polar compounds [9]. Different sizes of cartridges Cartridge size Easy separation difficult separation (10% loading) (1% loading) 4g 400mg 40mg 12g 1.2g 120mg 400mg 40g 4.0g 80g 8.0g 800g 120g 12g 1.2g 330g 33g 3.3g Sample injector This is used for the introduction of sample into the cartridge. Sample can be injected into the cartridge as liquid injection or dry sample [10]. Sample loading techniques in flash chromatography Loading in normal phase flash; o Solid loading. o Liquid injection. o o Loading in reverse phase flash: Solid loading; Liquid injection Sample loading in normal phase Flash

Solid loading For solid loading these are two components useful 1. Solid load cartridge 2. Cap Solid load cartridges are two types; 1. User packed solid load cartridge 2. Pre packed solid load cartridge User packed solid load cartridges Also called empty solid load cartridges Procedure Weigh sample to be separated. Determine amount of sorbent, o 20% load for silica. o 10% load for celite. Dissolves sample completely in less strong solvent. Mix with media. Dry on rotary evaporator. Place in cartridge. Add top frit. Insert solid load cartridge cap. This loading technique gives Best separation We can match sample size to silica for loading Allows user to use strong solvent to dissolve component Act as pre column Prevents clog from precipitated samples Pre packed solid load cartridge Dissolve sample Add to solid load cartridge Dry if desired by, o Vacuum dryer (or) o Vacuum oven Insert solid load cartridge cap. This loading technique gives Act as pre column. Increased column length due to extra silica. Liquid loading: Dissolve sample in large volume of weak solvent and inject directly in to the injection port. Liq. injection is fast and easy. Sample is dissolved in minimum strong solvent, gives better resolution. Sample is dissolved in large strong solvent, gives poor resolution. Loading in reverse phase Flash 330 Same as normal phase loading except that c18 silica or celite is used to load sample with 30% of water. Detectors Two types of detectors available 1. Uv detector. 2. ELSD (evaporating light scattering detector). Uv detector Principle: molecules have either n, pi, sigma or combination of these electrons. These bonding and nonbonding electrons absorb the characteristic radiation and undergoes transition from ground state to excited state. By the characteristic absorption peaks, the nature of the electrons present and molecular structure can be elucidated. Disadvantage: it can t detect non uv active compounds [9]. ELSD detector Principle of operation, It is a three step process. 1. Nebulization of the column effluent to form an aerosol. 2. Solvent evaporation with in heated drift tube. 3. Detection of the non volatile solute particles in the scattering cell. Nebulization The column effluent from flash separation enters the nebulizer where it mixed with steady stream of nebulizing gas to form aerosol. The aerosol consists of uniform distribution of droplets whose size dependent on the gas flow rate. The lower the gas flow rate used for the formation of larger droplets. Larger droplets scatter more light and increase sensitivity of the analysis, but they are also more difficult to evaporate in the drift tube. So optimal flow rate of each method will produce highest signal to noise ratio [10]. Evaporation Evaporation of the volatile components in the aerosol occurs in heated, stainless steel drift tube.

Drift tube temperature depend on mobile phase composition. Mobile phase flow rate, sample volatility. Organic mobile phases require lower drift tube temperatures. A stain less steel impactor is located three inches from the nebulizer. The plate is perpendicular to the aerosol path so the aerosol contacts the plate, larger droplets exit through the drain tube on the side panel. The remaining droplets pass around the impactor and travel through drift tube to the optical cell for detection [11]. Detection The non volatile sample particles emerge from the drift tube in the mobile phase vapor and enter the light scattering cell. In the optical cell, sample particles scatter light emitted by laser light source. The scattered light is detected by a silicon photodiode, generating a signal proportional to sample mass [12]. Disadvantage: volatile compounds can t be detected by this detector. Display This is used for the entering the run conditions. Monitor the signals obtaining from the detecto Touch pad solvent section start and stop Fractions collection Fraction collection trays are available to collect fractions. Waste collection The remaining solvent goes in to the waste collection. 331 Procedure Select the mobile phases for the separation of given compound. Insert in solvent lines into the solvent bottles. Before placing the solvent lines into the solvent bottles make sure that the solvent level sensors are at zero, otherwise make it zero by selecting zero button. After placing solvent lines in solvent bottles prime the solvent lines. This priming helps to remove previous run solvents and air present in lines. Make the gradient method, by entering the appropriate conditions for the separation of given mixture. Install the cartridge by lifting the cartridge arm. Prepare the sample as liquid or as solid. Run the method by selecting start button. The mobile phase passes from the cartridge and separate the mixture. The separated pure fractions collected in fraction collection trays. Remaining impure fractions goes in to the waste collection The detectors help in identifying and collection of compounds by giving sign [13]. Differences between Flash Chromatography and HPLC Flash HPLC Chromatography Low pressure(less than 200psi) High pressure (greater than 1000psi). Lower efficiency High efficiency columns. columns Focus on purification Focus on qualitative analysis and speed High flow and high sample loading Low flow and low sample loading Irregular shape of silica particlesparticles used. Spherical or angular shape of silica used Less solvent High solvent consumption consumption Typically silica based Typically modified silica normalphase basedreverse Phase Advanced Detection Techniques for Flash Chromatography UV detection is the traditional method used in Flash chromatography to monitor and fractionate peaks during the purification process. There are few detection options available in Flash chromatography for compounds that lack chromophores, and thus cannot be detected by UV. These invisible compounds may not be detected with

UV due to the absence of UV chromophores, or their absorbance may be lost in that of the solvents used in Flash chromatography. In other cases, the compounds absorption spectrum may be unknown and or detection was at a sub-optimal wavelength. Additionally, the UV absorption of the necessary mobile phase may interfere with the λ-max of the compound in question. In other cases, the absorption spectrum of the compound of interest or co-eluting impurities may not be known and therefore not detected. These advanced detection techniques allow users to easily fractionate compounds without the need for follow-up TLC and subsequent staining to determine where the purified compound eluted.evaporative Light Scattering Detection (ELSD) has long been used for High Performance Liquid Chromatography, but has only recently been employed for Flash chromatography. All- Wavelength Collection allows the collection of compound with unknown absorbance or collection in the presence of interfering solvent absorbance [13]. Green Flash Chromatography Green Flash Chromatography is the ultimate flash chromatographic technologythat achieves most efficient sample purification.the sample run is always carried out with minimum eluting volume.it minimizes run time and solvent use while achieving a good separation.it is Ecofriendly. Optimum method will be developed automatically based on the true theory of the flash chromatography, with the simple input of the TLC results, which allows easy sample purification. Features of Green Flash Chromatography Optimal parameters for flow rate, run time, fraction volume, etc. will be calculated and set automatically upon selecting a column on Green Flash software. The default parameters will be shown in System Setting window. Software provides the maximum sample load information for the selected column. State-Of-The-Art Software Based On True Theory of Chromatography. Sample Eluting Position and Resolution Can Be Fully Controlled for Systems. Automatic Method Setup for Reverse Phase Chromatography. Parallel Detection of UV Detector and RI Detector or ELSD [14]. Flash cromatographywithtlc image reader The system is equipped with a built-in UV light source and a camera. By shooting the TLC plate and clicking the target compound on the TLC plate, the Rf value of the target compound will be calculated and the optimized chromatography method will be developed automatically. The TLC plate is displayed on the screen during run. Compound spots on the TLC plate and the 332 compound peaks both are displayed on the screen. Both the photographic image of the TLC plate and the purification are saved as a data file. Click the target compound and the nearest impurity on the TLC plate, and the maximum sample load for each column will be automatically calculated. Thus, enabling the chemists to choose the best suited column for their sample [15]. Advantages Fast and economic methods for the synthesis laboratory.ideal for the separation of compounds up to gram quantities. No expensive equipment required. In an ideal way transfers results from TLC to CLC. Automated changes between normal phase and reversed phase chromatography. APPLICATIONS OF FLASH CHROMATOGRAPHY Natural Products/Nutraceuticals Application: Separation and Isolation of α-santalol and β-santalol from Sandalwood Extraction Isolation and Purification of Chromophoric and Nonchromophoric Compounds in Giant Knotweed Rhizome. Isolation and Purification of Flavonoids from Ginkgo Biloba Leaves Extract. Isolation and Purification of Ginsenosides from Red Panax Ginseng Extract. Isolation and Purification of Catechins from Green Tea Extract In Purification of GallaChinensis.Purification of Ferulic Acid in RhizomaChuanxiong Extract [16]. Carbohydrate Application Purification of Conjugated Quercetin and Rutinose. Impurity Isolation of Valproic Acid from CyclodextrinvDuring Encapsulation. Isolation ofaminosugar and Acarbose Flavanone Glycoside Purification. Isolation of Aminoglycoside Antibiotics. Lipids Application Purification of Fatty Acid Methyl Esters (FAMEs). Purification of a Mixture of Glycerides, Mono-, Di-, and Tristearin. Purification of Sterols. Pharmaceutical/Small Molecules Application Bile Acid Purification During Lead Generation in Drug Discovery. In Impurity Isolation During Drug Purification. Mestranol Purification During Chemical Synthesis. In Anti-malarial Drug Purification in Drug Discovery [17].

333 Instrumentation of Flash Chromatography

CONCLUSION The flash purification system provides time saving technology that increases productivity in the drug discovery process. It has an advantage of rapidly isolating and purifying compounds in less than 10 minutes. Compounds that cannot be separated on the same RP- HPLC chromatographic column due to their diverse 334 chemical nature can be separated by using flash cartridges. Flash Chromatography can be alternative to preparative HPLC as it saves time and solvent. Modern Flash chromatography with disposable cartridges and advanced detection techniques is applicable to a wide range of compounds REFERENCES 1. Macromedia Flash MX Action Script Bible, by Robert Reinhardt and Joey Lott. 2. Action Script for Flash MX: The Definitive Guide, Second Edition, by Colin Moock. 3. Still WC, Kahn M, Mitra A. Rapid Chromatographic Techniques for Preparative Separation with Moderate Resolution. J. Org. Chem., 43(14), 1978, 2923-2925. 4. Kuhler TC, Lindsten GR. Preparative Reversed-Phase Flash Chromatography, a Convenient Method for the Workup of Reaction Mixtures. J. Org. Chem., 48(20), 1983, 3589-3591. 5. O'Neil IA. A Convenient Method for the Large Scale Separation of Polar Compounds. Synlet, 1991, 661-662. 6. Still WC, Kahn M, Mitra A. J. Org. Chem., 43(14), 1978, 2923-2925 7. Laurence MH, Christopher JM. Experimental organic chemistry, 1989. 8. Fair JD, Kormos CM. J. Chromatogr. A, 1211(1-2), 2008, 49-54. 9. Harrison et al., Bioseparations Science and Engineering. Oxford University Press. New York, New York. 2003. 10. Still WC, Kahn M, Mitra A. J. Org. Chem., 43, 1978, 2923 2925. 11. Thompson WJ, Hanson BA. J. Chem. Educ., 61, 1984, 645. 12. Feigenbaum A. J. Chem. Educ., 61, 1984, 649. 13. Bell WL, Edmondson RD. J. Chem. Educ., 63, 1986, 361. 14. Jacobson BM. J. Chem. Educ., 65, 1998, 459. 15. Krause J. G. J. Chem. Educ., 68, 1991, 790. 16. Deal ST. J. Chem. Educ., 69, 1992, 939. 17. Potter GA. J. Chromatogr., 675, 1994, 237 239.