A FEM-based planning tool for the vibro-acoustic design of wooden floors at low frequencies

Similar documents
Characterisation of structure-borne sound sources

strategies to avoid boomy screeds

TFI Report Impact Sound Insulation

Sound insulation of planted noise barriers

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

TFI Report Impact Sound Insulation

Available online at ScienceDirect. Energy Procedia 78 (2015 ) th International Building Physics Conference, IBPC 2015

Laser scanning vibrometry measurements on a light weight building element

Postprint.

Measurement of airflow resistance by the alternating flow method

Modern measurement techniques in room and building acoustics

TRANSMISSION LOSS OF EXTRUDED ALUMINIUM PANELS WITH ORTHOTROPIC CORES

PREDICTION OF NOISE FROM MACHINERY IN TIMBER- FRAME BUILDINGS USING TRANSMISSION FUNCTIONS

Summary. The basic principles of the simulation technique SERT

Design possibilities for impact noise insulation in lightweight floors A parameter study

Shear at the interface between concrete cast

A DECOUPLED VIBRO-ACOUSTIC EXTENSION OF NASTRAN

Measurement of Acoustic Properties of light weight concrete SL-Deck

Rolf Diehl, Reinhard Gorlich and Georg Holzl 2 1 Introduction In the speed range from about 60 to about 250 km/h rolling noise is the dominant noise f

1238. Relation between reduction of weighted impact sound pressure level and shape of small size specimen of floating floor construction

Variability in structure-borne flanking transmission at low and mid frequencies

Structure-borne Sound Sources in Buildings

Thermal Analysis for Solid Structures

Reciprocity as an Analysing Technique in Building Acoustics

The temperature development of hot dip galvanized steel members in fire

A Modal Approach to Lightweight Partitions with Internal Resonators

LABORATORY MEASUREMENTS OF THE REDUCTION OF TRANSMITTED IMPACT NOISE PANETTI OVERLAID BY CONCRETE FLOORING

TFI Report Sound Absorption Impact Sound Insulation

MATERIAL CHARACTERIZATION, VIBRO-ACOUSTIC ANALYSIS AND MANUFACTURING OF TEXTILE-REINFORCED COMPLEX 3-D COMPOSITE STRUCTURES

Investigations to determine the dynamic stiffness of elastic insulating materials

Vibration analysis of concrete bridges during a train pass-by using various models

Mass Timber Floor Vibration

The equivalent translational compliance of steel studs and resilient channel bars

A reciprocity relationship for random diffuse fields in acoustics and structures with application to the analysis of uncertain systems.

ISO INTERNATIONAL STANDARD

EVALUATION OF FOOTFALL-INDUCED VIBRATIONS AND THEIR IMPORTANCE IN A BIOMECHANICS LABORATORY

Measuring system for sound source location for a systematic design modification of electrical machines

New techniques in computer aided noise abatement for workplaces next to machinery Wolfgang Probst

Titelmasterformat durch Klicken bearbeiten

Transparent building elements. Translucent building elements. Environmental Product Declaration (EPD) Short version Declaration Code: EPD-RLE-33.

ISO INTERNATIONAL STANDARD

TFI Report Sound Absorption Impact Sound Insulation

The influence of Boundary Conditions on Sound Insulation

EVALUATION OF THE RADIATED SOUND POWER OF LIGHTWEIGHT BUILDING CONSTRUCTIONS BASED ON LASER SCANNING VIBROMETER MEASUREMENTS

Prediction of Light Rail Vehicle Noise in Running Condition using SEA

Radiated Sound Power from a Curved Honeycomb Panel

Sound field decomposition of sound sources used in sound power measurements

TFI Report Sound Absorption Impact Sound Insulation

Radiated sound power estimates of building elements by means of laser Doppler vibrometry

INDUSTRIAL TRIALS OF A SYSTEM FOR MEASUREMENT OF COUPLING FORCES

RFS2-CT Background Document for Floor Vibrations

Active Impact Sound Isolation with Floating Floors. Gonçalo Fernandes Lopes

Answer - SAQ 1. The intensity, I, is given by: Back

Evaluation of standards for transmission loss tests

FLOOR VIBRATIONS FREQUENTLY ASKED QUESTIONS AND MORE. Frequently Asked Question. Questions Concerning Design for Walking Excitation

TFI Report Sound Absorption Impact Sound Insulation

Creep and Shrinkage Calculation of a Rectangular Prestressed Concrete CS

ACOUSTICS 1.01 Pantone 144 U & Pantone 5405 U

ON SOUND POWER MEASUREMENT OF THE ENGINE IN ANECHOIC ROOM WITH IMPERFECTIONS

Acoustic design of lightweight cabin walls for cruise ships

Calculating the heat transfer coefficient of frame profiles with internal cavities

ACOUSTIC NOISE AND VIBRATIONS DUE TO MAGNETIC FORCES IN ROTATING ELECTRICAL MACHINES

Structural Dynamic Behavior of a High-Speed Milling Machine

Sound Insulation and Flanking Transmission: from U.E. Directive 89/106 to the flanking transmission loss experimental measurement

SVENSK STANDARD SS-EN

Integration of measured receptance into a time domain simulation of a Multi Body Model using SIMPACK

Titelmasterformat durch Klicken bearbeiten

Numerical modeling of the primary source in a hemi-anechoic room

Measurement Uncertainty in Mechanical Testing

Acoustic response in non-diffuse rooms

ISO 354 INTERNATIONAL STANDARD. Acoustics Measurement of sound absorption in a reverberation room

EDware. Squeak & Rattle Forum, Würzburg, 2012

REVERBERATION TIME, STRENGTH & CLARITY IN SCHOOL HALLS: MEASUREMENTS AND MODELLING

Behavior of Curtain Walls Heating Reduction of Buildings in Summer Situations or in Hot Climates

Chapter 6. Summary, Conclusions, and Recommendations for Future Research. 6.1 Summary

Objective and Subjective Evaluation of Floor Impact Noise

Broadband Vibration Response Reduction Using FEA and Optimization Techniques

Prof. Dr. Ing. W. Weingart Hochschule Anhalt (FH) FB Architektur und Bauwesen Abteilung Strassenbautechnik Dessau. 17 April 2005

Critical loss factor in 2-DOF in-series system with hysteretic friction and its use for vibration control

Influence of background noise on non-contact vibration measurements using particle velocity sensors

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

NOISE & VIBRATION MITIGATION IN RAILWAY TRACK

Prediction of the radiated sound power from a fluid-loaded finite cylinder using the surface contribution method

Review of the Impact Ball in Evaluating Floor Impact Sound

Compensation-based non-destructive automatic quality control using acoustic methods

Sound radiation and sound insulation

25/01/2013. Agenda. Advanced Approaches to Modeling and Assessment of Floors for Control of Human Activity. Ultra-Low Vibration Environments

VK2 volume flow controller Overview

Yalıtım Kontrol Koruma. Insulation Control Protection

The practical application of G and C 50 in classrooms

Fundamentals of silencing and their practical application in screw compressor plants

CONTRIBUTION TO THE IDENTIFICATION OF THE DYNAMIC BEHAVIOUR OF FLOATING HARBOUR SYSTEMS USING FREQUENCY DOMAIN DECOMPOSITION

Sound power level measurement in diffuse field for not movable sources or emitting prominent discrete tones

Vibration serviceability assessment of a staircase based on moving load simulations and measurements

ACOUSTIC RADIATION BY SET OF L-JOINTED VIBRATING PLATES

Design of floor structures for human induced vibrations

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

This document is a preview generated by EVS

A 3D-ball bearing model for simulation of axial load variations

Numerical Analysis of Comfort and Energy Performance of Radiant Heat Emission Systems

Transcription:

A FEM-based planning tool for the vibro-acoustic design of wooden floors at low frequencies Mathias KOHRMANN 1 ; Martin BUCHSCHMID 2 ; Ulrich SCHANDA 3 ; Gerhard MÜLLER 4 1 Hochschule Rosenheim, Germany 2 Technische Universität München, Germany 3 Hochschule Rosenheim, Germany 4 Technische Universität München, Germany ABSTRACT Within the scope of the recently finished cooperate research project VibWood at Technical University Munich and Rosenheim University of Applied Sciences, fully parametrized numerical models for wooden floor constructions have been developed and calibrated by experimental modal analyses. Based on a vast parametric study including floating floors and suspended ceilings a database of narrowband sound power levels in the frequency range up to 125 Hz for a wide range of floor dimensions has been set up. A procedure will be presented on how to process the numerical data and derive single number values that allow a comparison to the standardized rating of impact sound insulation according to DIN EN ISO 717-2. The derived data is implemented into a graphical user interface (GUI). This GUI is available for free. The database is open for additional geometries and will be enhanced by different constructions in the near future. Keywords: Vibro-acoustic, Impact noise, Design guideline I-INCE Classification of Subjects Number(s): 51.3, 72.4, 74.1, 75.3, 75.6 1. INTRODUCTION Timber constructions in multi-storey buildings for industrial as well as for residential use have been rapidly growing its market share in recent years. This can be explained on the one hand by reasons of profitability. Wood is light in weight; therefore a high degree of prefabrication is possible and also leads to less transportation and storage costs. On top of that adding another storey to an existing building is often only possible using timber constructions. On the other hand regarding the necessity to develop sustainable construction concepts timber constructions have advantages as wood is a renewable raw material. The serviceability linked with vibrations as well as the proof for footfall noise insulation are key issues for such light-weighted structures, especially for timber floors. In particular in the frequency range below 125 Hz timber structures are prone to pedestrian induced vibrations, footfall noise as well as re-radiated sound caused by induced vibrations. During the last decades the human perception of floor vibrations has been subject to a large number of researches. Several design guidelines have been proposed starting from the limitation of deflections over subjective assessment-based methods towards dynamic response-based methods, as in actual European standardizations [1]. Most of them mainly focus on the limitation of the fundamental natural frequency achieved by simplified calculation models. These often lead to a conservative prediction [2]. In practice a modified method is widely used which has been developed during a research project at Technical University Munich (TUM) [3]. In the absence of a practically applicable design guideline, simplified models are used for the prediction of the footfall noise insulation of wooden floor constructions [4]. This leads to comfort problems that arise, even if the requirements according to actual standardizations are met [6]. The same holds for concrete floors. Booming of the floating floor was identified as a possible reason, for 1 mathias.kohrmann@fh-rosenheim.de 2 martin.buchschmid@tum.de 3 ulrich.schanda@fh-rosenheim.de 4 gerhard.mueller@tum.de 3743

which Burkhard [7] proposed an evaluation model. In addition, in case of wooden floors a discrepancy is observable between subjective perception and measurement based proof, which is caused by the difference between the excitations of a walking pedestrian and the standard tapping machine. Rabold [6] compared alternative design approaches and derived target values for the design of wooden floors. In summary there is a requirement for more detailed models to predict the vibro-acoustical behavior of wooden floor constructions. Since measurement based investigations are time consuming and cost intensive a possible alternative is the development of numerical models. In recent years several research has been carried out on that topic [8] [9] [10]. The scope of the recently finished research project VibWood was the development of parametrical Finite-Element (FE) models of wooden floor constructions for the simulation of the vibro-acoustical behavior in the frequency range up to 125 Hz and the development of design guidelines [11]. 2. Research project VibWood The project was carried by a cooperation between the TUM and the University of Applied Sciences Rosenheim (HSRo). It was intended to investigate representative floor constructions to cover the main common wooden floor types. Therefore lumber joist (LJ) and cross-laminated-timber (CLT) floors in varying construction states with floating floor (FF) and suspended ceiling (SC) were examined. For every floor construction a fully parametrized numerical model has been developed at the TUM (see fig. 1). The models have been calibrated and updated by means of modal parameters (Eigen frequency, modal damping and mode shapes) derived by measurement based investigations [12]. Therefore experimental and operational modal analyses have been carried out in the floor testing facility of the Labor für Schallmesstechik (LaSM) at the HSRo (see fig. 2) [13]. Figure 1 FE model of a CLT floor with FF and SC Based on the calibrated, numerical models extensive parametric studies have been performed extending dimensions of the testing facility and thus extrapolating over a wide range of practical relevant floor dimensions. Modal and harmonic frequency response analyses have been carried out in the frequency range up to 125 Hz aiming at evaluation of the Eigen frequencies as well as the frequency dependent radiated sound power of the individual floor constructions. A simulation of the total frequency range, which is relevant in building constructions, was not possible, since the occurring small wavelengths cannot be modeled by the applied FE method. The adjacent receiving room was not part of the models in order to reduce the computational effort. Thus the evaluations aimed at the prediction of the radiated sound power. It was approximated according to the theory of a plane radiator as sum of plain waves [14] out of the simulated structure borne velocity pattern at the floors lower surface. Therefore an acoustical evaluation model based on integral transform methods (ITM) was developed, which analyses the simulated vibration response in the wave number domain [15]. A high precision compared to experimental data could have be achieved. 3744

Figure 2 Example of a measured frequency response function at the driving point with visualizations of the corresponding Eigen modes. Thus a data base for every parameter combination and construction state was derived containing the individual Eigen frequencies as well as the resulting radiated sound power. The later was stored as small band transfer functions related to the induced excitation. The derived data is accessible for engineering purposes via a graphical user interface. 3. Graphical user interface The graphical user interface developed within pursuing research at HSRo combines multiple evaluation possibilities. An example is shown in figure 3. Since the program is designed in German language the following section will provide hints on the translation. The floor constructions of interest (Deckensystem) as well as its dimensions (Länge, Breite) can be chosen in the input section (Eingangsdaten). Further an excitation type (Lastspektren) can be chosen for an acoustical evaluation as well as a specific weighting function (Bewertungsfilter). Thus the stored transfer functions are multiplied by the load spectra of a walking pedestrian or a standard tapping machine to derive the resulting radiated sound power. Up to three different floor constructions can be displayed (different color) and compared for both types of excitation. The acoustical evaluation can be done in three different ways with varying degree of detail. The standard configuration shows the third octave spectra of the sound power level from 31.5 to 100 Hz. For more detailed considerations the small band results accompanied by the individual radiation efficiency (Abstrahlgrad) can be opened in a Pop-Up window. A fast comparison of different constructions can be done by single values, also a classification according to the predicted standard footfall noise level can be done. The derivation of the single value is subject of the next section. As an additional functionality the statutory proof of the serviceability linked to vibrations (Gebrauchstauglichkeitsnachweis) can be provided for the chosen floor. This can be done according to EUROCODE 5 or optional by the modified method developed by Hamm and Richter [3]. An advantage compared to already existing tools consists of the possibility to compare the calculated to the simulated results. Thus possible oversizing caused by the simplified calculation approach can be identified and avoided. 3745

Figure 3 Graphical user interface; a comparison of the radiated sound power (Schallleistungspegel) of three different floor constructions for excitations by a pedestrian (Geher) and by the standard tapping machine (Hammerwerk) 4. Single values for the evaluation at low frequencies A direct calculation of the standard footfall noise level L n,w according to [5] is not possible using the simulated data, due to the insufficient simulated frequency range. Thus a coefficient derived from the simulated data, must be developed, which correlates with the single value L n,w. Therefore in a first step the radiated sound power is evaluated for an excitation with a standard tapping machine. The resulting small band spectra are subsequently transformed into third octave bands. The sound power level can then be transferred into a sound pressure level under simplified assumptions of a diffuse sound field according to equation (1). L p, i, diffus 2 4m LW, i 10log10 (1) A For reasons of comparability of the results the equivalent sound absorption area A eq of 10 m 2 (=A 0 ) is chosen according to DIN EN ISO 717-2. To consider the psycho-acoustical perception the results are further processed by applying the perception threshold according to DIN 45680 [16]. Figure 4 shows an example of a third octave sound pressure level with superimposed perception threshold. The sum level of the values above this threshold serves as the desired coefficient. An investigation of the simulated results showed, that the sum level from 50 to 100 Hz (L sum,50-100 ) gives quite satisfying results. The third octave bands below 50 Hz have only a minor impact on the result. In addition, this frequency range is covered by the usual measurement frequency range of impact sound insulation. As a validation the developed coefficient is compared to the loudness computed out of the same set of data according to the method proposed by E. Zwicker [17]. As shown in Figure 5 a good correlation can be achieved. eq 3746

Figure 4 Example of a simulated sound pressure level of a LJ floor with FF and SC (blue); superimposed: the perception threshold (orange) and the values above the threshold (red) Figure 5 Correlation of the coefficient L sum,50-100 compared to the loudness by Zwicker for LJ and CLT floors exited by the standard tapping machine 3747

A similar evaluation can be performed for an excitation by a force spectrum of a walking pedestrian [18]. In this case the lower frequency bands do have a major impact. Thus the coefficient for a pedestrian excitation is formed by the sum level of the third octave bands from 25 to 100 Hz. Figure 6 shows again the correlation to the loudness. A force spectrum of a pedestrian of 75 kg with a footstep frequency of 1.6 Hz was applied. Again a good correlation can be observed. Especially the floors with an additional screed (FF) show lower sum levels respect. loudness. Figure 6 Correlation of the coefficient L sum,25-100 compared to the loudness by Zwicker for LJ and CLT floors with pedestrian load The coefficients out of the simulated data cannot directly be compared to the impact sound level as mentioned before. Instead a comparison based on measurement data is performed as shown in figure 7. It shows the database for varying wooden floor constructions archived by the IFT Rosenheim, out of which the construction catalogue for [19] was derived. Here the coefficient L sum,50 100 is compared to the standard footfall noise level L n,w complemented by the spectrum adaptation value C I,50 2500. A good linear correlation is observable. The values differ only by a fixed value of 12.5 db with a standard deviation of ±1.8 db. Thus the estimated L n,w + C I,50 2500 can easily be extrapolated from the coefficient L sum,50 100. For a maximum footfall noise level of 53 db, as proposed by [6] for a sufficient comfort level, a floor construction meets the requirements for a L sum,50 100 lower than 43 db. A comparison between an excitation by a standard tapping machine and a pedestrian load is shown in figure 8. No correlation can be observed, but clearly the different construction states form clusters. Floors with FF in general have lower coefficients for excitations by a pedestrian, even if the coefficient linked to the standard tapping machine excitation vary. This behavior might be caused by the simulated FF, which was chosen to have a high mass-spring-mass resonance frequency at about 100 Hz according to the goal of the Vibwood project. Thus the typical booming did not appear and the FF was acting only as additional mass in the frequency range below 100 Hz. At the same time this decreases the effectiveness of the FF with respect to impact sound insulation. Further research is intended, which includes the simulation of varying mass-spring-mass resonance frequency to complement the database. 3748

Figure 7 Correlation between the coefficient L sum,50 100 and the impact sound level with spectrum adjustment value L n,w + C I,50 2500 for measurement data of different wooden floor constructions (IJ: I-joist floor, HBG: hollow-box-girder); superimposed: a linear trend line with 95% confidence bounds Figure 8 Correlation between the coefficient L sum,50 100 (tapping machine) and L sum,25 100 (pedestrian) for LJ and CLT floors 3749

5. CONCLUSIONS The presented planning software will provide the practical engineer with the advantages of a numerical simulation without the cost and time intensive calculation effort. The disadvantage of the limited frequency range could be compensated by an adequately chosen coefficient which allows an interpolation for the estimated standard footfall noise level. The combination with the possibility to provide the proof of serviceability linked with vibrations contributes an additional value especially for the prevention of oversizing the constructions. Up to now the database is limited to only floor constructions of a few fabricants, but the program can be complemented by additional systems. ACKNOWLEDGEMENTS The IGF project 16758 N des ivth (Internationaler Verein für technische Holzfragen e.v.) was supported by the AIF (Allianz Industrie Forschung). Technical support was provided by Müller BBM VAS. REFERENCES 1. Weckendorf, J., Toratti, T., Smith, I., Tannert, T.: Vibration serviceability performance of timber floors. Eur. J. Wood Prod., Springer-Verlag, Berlin, Heidelberg, 2015 2. DIN EN 1995-1-1:2010-12. Eurocode 5: Bemessung und Konstruktion von Holzbauten; Teil 1-1: All- gemeines - Allgemeine Regeln und Regeln für den Hochbau. Deutsches Institut für Normung e.v., Beuth Verlag 3. Winter, S., Hamm, P., Richter, A.: Schwingungstechnische Optimierung von Holz- und Holz-Beton-Verbunddecken: Entwicklung von Bemessungs- und Konstruktionsregeln auf der Grundlage eines kalibrierten FEM-Modells und unter Berücksichtigung des Dissipations-Potentials unterschiedlicher Deckenaufbauten. TU München, Forschungsbericht, 2010 4. DIN 4109:1989-11. Schallschutz im Hochbau - Anforderungen und Nachweise. Deutsches Institut für Normung e.v., Beuth Verlag 5. DIN EN ISO 717-2:2013-06. Akustik Bewertung der Schalldämmung in Gebäuden und von Bauteilen Teil 2: Trittschalldämmung. Deutsches Institut für Normung e.v., Beuth Verlag 6. Rabold, A.: Trittschalldämmung richtig bewerten. 1. Internationale Schall- und Akustiktage, 2011 7. Burkhart,C.: Tieffrequenter Trittschall Messergebnisse, Beurteilung. Tagungsband DAGA, 2003 8. Rabold, A.: Anwendung der Finite Element Methode auf die Trittschallberechnung. Technische Universität München, Dissertation, 2010 9. Flode, O.: Vibrations in lightweight structures - efficiency and reduction of numerical models. Lund Universität, Schweden, Dissertation, 2014 10. Churchill, C., Hopkins, C., Krajci, L.: Modelling airborne sound transmission across a hybrid heavyweight-lightweight floor using Statistical Energy Analysis. Forum Acusticum, 2011 11. Kohrmann, M., Völtl R., Müller G., Schanda U., Buchschmid M.: Planungshilfen zur schall- und schwingungstechnischen Beschreibung von Holzdecken und zur Bewertung und Dimensionierung von angepassten Schwingungsschutzsystemen. TU München und HS Rosenheim, Research report, 2014 12. Kohrmann, M., Buchschmid, M., Greim, A., Müller, G., Schanda, U.: Vibroacoustic Characteristics of light-weighted Slabs - Part 1: Aspects of Numerical Modeling, Model Updating and Parametric Stu- dies using the Buckingham π-theorem. Proceedings AIA-DAGA, Meran, 2013 13. Völtl, R., Kohrmann, M., Buchschmid, M., Schanda, U., Müller, G.: Messung und Berechnung der Schwingungen von Holzdecken im Prüfstand. Tagungsband DAGA, Darmstadt, 2012 14. Cremer, L., Heckl, M., Petersson, B. A. T.: Structure-Borne Sound - Structural Vibrations and Sound Radiation at Audio Frequencies. Springer-Verlag, Berlin, Heidelberg, 2005 15. Kohrmann, M., Buchschmid, M., Müller, G., Völtl, R., Schanda, U.: Numerical models for the prediction of vibro-acoustical characteristics of light- weighted ceilings, Proceedings Internoise, Innsbruck, 2013 16. DIN 45680:2013-09 Entwurf. Messung und Beurteilung tieffrequenter Geräuschimmissionen. Deutsches Institut für Normung e.v., Beuth Verlag 17. DIN 45631:1991-03. Berechnung des Lautstärkepegels und der Lautheit aus dem Geräuschspektrum - Verfahren nach E. Zwicker. Deutsches Institut für Normung e.v., Beuth 3750

Verlag 18. Schanda, U., Tröbs, H.-M., Völtl, R., Becker, P.: Semi-empirical model of the impact force of a walking person in the time domain and generated impact sound spectra, Proceedings Internoise, Innsbruck, 2013 19. DIN 4109-33:2013-12 Entwurf. Schallschutz im Hochbau - Teil 33: Eingangsdaten für die rechnerischen Nachweise des Schallschutzes (Bauteilkatalog) Holz-, Leicht- und Trockenbau, flankierende Bauteile. Deutsches Institut für Normung e.v., Beuth Verlag 3751