Impact of New SSL Standards on Goniospectroradiometric Measurements

Similar documents
Burning position correction for measurements with the turning luminaire LGS 1000

Measurement method for the proficiency testing program

LM Test Report. For. Beyond LED Technology. (Brand Name: Beyond LED) 2725 Mountain Industrial Blvd. Suite A-1 Tucker, GA 30084

NVLAP LAB CODE LM Test Report. For REMPHOS TECHNOLOGIES LLC. (Brand Name: ) 90 Holten St, Danvers, MA 01923,USA.

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006

RoHS. Dimming: PWM/VR/0-10V QPL ID # PL21D5Q1B95E. Cat# W LED FlatPanel Slipfitter Mount. EPA Rating 2.

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD

NVLAP LAB CODE LM Test Report. For. Shenzhen Guanke Technologies Co. Ltd. (Brand Name: )

NVLAP LAB CODE LM Test Report. For AOK LED LIGHT COMPANY LIMITED. (Brand Name: AOK)

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006

NVLAP LAB CODE LM Test Report. For AOK LED LIGHT COMPANY LIMITED. (Brand Name: AOK)

LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl350u1

NVLAP LAB CODE LM Test Report. For LED PANEL LIGHTING CO.,LTD. (Brand Name: N/A)

NVLAP LAB CODE LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl5s50u1

Cat# LED High Bay

NVLAP LAB CODE LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl4s50u1

Page 2 of 14 Report No.: Test sample... : Type of test object... : LED Downlight LED Downlight

Photometric Laboratory Measurement report G001

NVLAP LAB CODE LM Test Report. For. LED Wav es,inc. (Brand Name: LED Wav es)

NVLAP LAB CODE LM Test Report. For SIMKAR CORPORATION. (Brand Name: ) LED Lamp. Model name(s): SALXS350U1. Model differences: N/A

NVLAP LAB CODE LM Test Report. For SIMKAR CORPORATION. (Brand Name: ) LED Lamp. Model name(s): SALXS450U1. Model differences: N/A

NVLAP LAB CODE LM Test Report. For IGT LIGHTING INC. (Brand Name: IG T ) 3755 Lincoln St. Suite B, Riverside, CA 92503

Optical Measurement Guidelines for High-Power LEDs and Solid State Lighting Products

LightLab I N T E R N A T I O N A L

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

LED Entryway Light RoHS

Solid State Lighting Annex: Interlaboratory Comparison Test Method

Wet Locations Use 71400A 120 W PF V 2.9A 93% 144 pcs. Philips 130 LM/W 5000K Hrs. 5 Years. 24-1/4 Lbs 665*530*120 1 PCS

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

NVLAP LAB CODE LM Test Report. For CE INNOVATIONS LTD. (Brand Name: N/A) 911 Denison St Markham, ON L3R 3K4 Canada

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

LightLab I N T E R N A T I O N A L

Photometric Test Report

NIST Role in Supporting Solid State Lighting Initiative

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

LM Test Report. for. Forest Lighting Corporate. LED Tube. Model: FL-T8U BN

PHOTOMETRIC TESTING & EVALUATION TO IES LM Sample Tested LN130-A30 LED HIGH BAY. Prepared for: Janie Chung

LightLab I N T E R N A T I O N A L

Report No.: HZ p. (Lumens) Stabilization Time CRI (K)

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Morris Products 53 Carey Road, Queensbury, NY 12804

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Standard-Tech Co. Ltd Testing Center

NVLAP LAB CODE LM Test Report. For. Hocan Group Co.,Ltd (Brand Name: SEPICN LED LIGHTING)

NVLAP LAB CODE LM Test Report. For. Hocan Group Co.,Ltd (Brand Name: SEPICN LED LIGHTING)

Practical Optical Measurements of OLED Panels for Lighting Applications

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Photometric Test Report. Keystone Technologies

Photometric Test Report. Keystone Technologies

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

MODEL NAME : LLDMWW0-15K*0*A

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Photometric Test Report

Cat# LED Linear High Bay 100W

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

LightLab I N T E R N A T I O N A L

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

LightLab I N T E R N A T I O N A L

Photometric Test Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Photometric Test Report

LM Test Report. for MLS CO., LTD. Linear Ambient Luminaires Model: MT8N20-A

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Calibration Due Date Chroma Programmable AC Source 61604

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

LM Test Report. for MLS CO., LTD. Linear Ambient Luminaires Model: MT5Z02-6

Transcription:

Impact of New SSL Standards on Goniospectroradiometric Measurements By Dr. Ðenan Konjhodžić, Application Engineer Presented by Justin Blanke, International Sales Manager

Outline Goniophotometry and goniophotometer types LM-79-08 review New standards EN 13032-4 and CIE S 025 Resulting requirements on measurement equipment Example: Correction of burning position Solution for turning luminaire Comparative application study 2

Moving detector & mirror goniophotometer Moving detector type Detector moves around the source on an arm or rail Large samples require large space for far field measurements Not best solution for luminous intensity but good for luminous flux integration Moving mirror type Detector is fixed Luminaire turns around the vertical axis only Mirror moves around luminaire Polarisation sensitive Very large and expensive systems 3

Turning Luminaire Goniophotometer Horizontal optical axis in conformity with C,γ - coordinate system (CIE 121-1996) C-axis γ-axis Advantages: Relatively small and compact envelope Far field measurement can be easily realized even for large samples Less expensive than moving mirror type Disadvantage: Burning position not maintained Solution: Correction of the burning position in conformity with new standards EN 13032-4 and CIE S 025 4

LM-79: Goniophotometer requirements Type C geometry maintaining the burning position Detector distance 5 x sample diameter (less for flux) No ventilation from air flow affecting the measurement (speed dependent!) Ambient temperature 25 C ± 1 C, measured up to 1 m away from the SSL product, same height Stabilization / warming up: typ. 30 min 2 h until stable within 0,5 % when 15 min apart Sample orientation as intended by the manufacturer 5

New standards EN 13032-4 and CIE S 025 Draft of an European standard EN 13032-4 has been published end 2013. Final standard published in August 2015. International Standard CIE S 025:2015 has been published in March 2015. Both standards have identical technical content. CIE S 025 is planned as an ISO/CIE/IEC Triple Logo standard. It is the first international guideline to cover the measurement procedures for SSL products and will exert a significant influence on the proposed harmonization. 6

Worldwide impact of CIE S 025 7

Coverage of the standard Standard covers photometric and colorimetric measurements of LED lamps, LED modules (light engines) and LED luminaires (DIN 5032-9 covers OLEDs). It includes total (partial) luminous flux, luminous efficacy, luminous intensity distributions, center-beam intensity, luminance and luminance distribution, chromaticity coordinates, CCT, CRI and angular color uniformity. 8

Scope and principles of measurements No restrictions on the used measurement technique. Techniques other than the explicitly mentioned are acceptable if demonstrated to produce equivalent results. Specific requirements on test equipment and test conditions are given by a set value and a tolerance interval. The test result has to be within the acceptance interval or a correction has to be applied. The user has to set up an uncertainty budget according to ISO/IEC Guide 98-3 or CIE 198. Further guidance will be prepared as a supplement to the standard and published as a technical note. 9

Standard test conditions Standard test conditions given by a set value and a tolerance interval 10

Example: Correction of burning position Some special requirements may be corrected, e.g. burning position CIE S 025 allows goniometric measurements to be performed in an orientation other than the designed burning position, if corrected. Turning-luminaire type may be used. One possible correction is the auxiliary photometer method. This method is implemented by a short additional test with correction steps that are easily automated in software. 11

Auxiliary photometer method An adapter with an auxiliary photometer fixed to the mounting plate. A change in luminous flux of the DUT, caused by changing the burning position, results in a proportional photocurrent. 12

Auxiliary photometer method Additional cantilever allows turning the sample into designed burning position even when it is switched on. The subsequent measurement of a reference without interruption. 13

Outline Goniophotometry and goniophotometer types LM-79-08 review New standards EN 13032-4 and CIE S 025 Resulting requirements on measurement equipment Example: Correction of burning position Solution for turning luminaire Comparative application study 14

Setup for Turning Luminaire Photometer head or a probe for spectroradiometer as detector Stray light tube as a shield Distance min. 10 x source dimension Correction of the burning position using the auxiliary photometer method in conformity with CIE S 025 15

Setup for Luminous Flux Integrator Transformation to a goniometer with a rotating detector Additional sample holder maintains the burning position Photometer or / and spectrometer as detector For small light sources all spatial radiation patterns can be measured 16

Test comparison Light source beam angle Ф v [lm] lum. flux integrator Ф v [lm] luminous flux integrator Ф v [lm] turning luminaire Photometer Spectrometer Photometer SSL downlight 1 97 798.0 806.0 1.0% 806.9 1.1% SSL downlight 2 80 665.3 673.5 1.2% 671.9 1.0% SSL downlight 3 52 1834 1854 1.1% 1878 2.4% SSL downlight 4 29 403.0 408.7 1.4% 409.4 1.6% LED module with cooler 104 1167 1181 1.2% 1178 0.9% LED floodlight 103 1697 1693-0.2% 1743 2.7% Sun lamp (halogen) 32 4150 4231 2.0% 4021-3.1% SSL downlights The deviations within measurement uncertainties Other sources The deviations are still low but a position correction can be applied 17

Correction of the burning position Light source Ф v [lm] turning luminaire Ф v [lm] turning luminaire corrected LED floodlight 1743 2.7% 1702 0.3% Sun lamp (halogen) 4021-3.1% 4111-0.9% SSL downlight 1 @ 215 V 721.8-9.5% 805.8 1.0% SSL downlight 1 @ 200 V 650.9-18.4% 806.9 1.1% Induced position dependence for SSL downlights: SSL downlight 1 was measured at lower operating voltages (215 and 200 V). The reference value was recorded in the designed burning position at the rated voltage of 230 V and used for position correction. 18

Conclusions New standards EN 13032-4 and CIE S 025 allow goniophotometric measurements in a luminaire orientation other than the designed burning position, if properly corrected. Correction with an auxiliary photometer method presented. Turning luminaire with a compact footprint provides a genuine alternative to a large and expensive rotating mirror goniophotometer even for position sensitive samples. 19

Thank you for your attention! www.instrumentsystems.com 20