CATALYSIS & THERMAL ANALYSIS

Similar documents
Hiden CATLAB Systems Microreactor for Catalysis Studies & Thermal Analysis

Hiden HPR60 Molecular Beam Mass Spectrometer System

Catalysis CAPABILITIES

Pressure & temperature sampling options for Hiden gas analysis systems

SURFACE ENGINEERING MASS SPECTROMETERS FOR THIN FILMS, PLASMA AND SURFACE ENGINEERING

vacuum analysis plasma diagnostics surface science gas analysis

THIN FILMS, PLASMA & SURFACE ENGINEERING. Mass Spectrometers. for Thin Films, Plasma & Surface Engineering

Hiden SIMS Secondary Ion Mass Spectrometers. Analysers for surface, elemental and molecular analysis

Hiden Isochema. Gravimetric Gas & Vapor Sorption Analyzers. Hiden Isochema IGA Series. Advancing Sorption Analysis

Mass Spectrometers. for Surface Analysis SURFACE ANALYSIS

RESIDUAL GAS ANALYSIS MASS SPECTROMETERS FOR RESIDUAL GAS ANALYSIS - RGA

Application of the EQP and EQS mass spectrometers to time resolved studies in ion beam and plasma processes

SNMS. SNMS Applications. Combined SIMS and SNMS

Hiden Analytical Ltd

Extrel is widely respected for the quality of mass spectrometer systems that are

Defining quality standards for the analysis of solid samples

SIFT-MS. technology overview

Mass Spectrometer A Comparison of Positive and Negative Ion RGA Methods

SIFT-MS SELECTED ION FLOW TUBE MASS SPECTROMETRY TECHNOLOGY OVERVIEW \ SYFT TECHNOLOGIES

Gravimetric Analysers for the Characterisation of the Sorption Properties of Materials.

Hiden EQP Systems. High Sensistivity Mass and Energy Analyzers for Monitoring, Control and Characterization of Ions, Neutrals and Radicals in Plasma.

XEMIS NEXT GENERATION GRAVIMETRIC SORPTION ANALYZER

CuSO 4.5H 2 O Analysis with a Hyphenated TGA 8000 and Hiden Analytical HPR-20 EGA Mass Spectrometer

HYPHENATED TECHNOLOGY GUIDE

AutoChem II 2920 A Catalyst Characterization Laboratory

Extrel Application Note

Plasma Diagnostics Introduction to Langmuir Probes

ICP-MS. High Resolution ICP-MS.

PERSPECTIVE STABLE ISOTOPE RATIO MS

HYPHENATED TECHNOLOGY GUIDE

DYNAMIC VAPOR SORPTION ANALYZER FULLY AUTOMATED COMPACT BENCH-TOP DVS ANALYZER, FOR FAST AND ACCURATE SORPTION MEASUREMENTS.

Thermo Scientific ICP-MS solutions for the semiconductor industry. Maximize wafer yields with ultralow elemental detection in chemicals and materials

Finnigan LCQ Advantage MAX

IRMS. perspective. Isotope Ratio Mass Spectrometry.

Application Note GA-301E. MBMS for Preformed Ions. Extrel CMS, 575 Epsilon Drive, Pittsburgh, PA I. SAMPLING A CHEMICAL SOUP

for XPS surface analysis

Agilent 7500a Inductively Coupled Plasma Mass Spectrometer (ICP-MS)

PERSPECTIVE STABLE ISOTOPE RATIO MS

FIB - SIMS. Focussed Ion Beam Secondary Ion Mass Spectrometry.

BOXA-II ON-STREAM X-RAY FLUORESCENCE ANALYZER. Technical Description Version 2 BGRIMM AUTOMATION

Chemical Analysis. Low Level Oxygenates Analyzer. Trace Analysis of Oxygenates in Hydrocarbon Matrices. Gas Chromatography.

SOPHISTICATED DESIGN, INTUITIVE OPERATION, RESEARCH-GRADE RESULTS

Analysis of TO-15/TO-17 air toxics in urban air using TD GC/TOF MS and automated compound identification software

Thermo Scientific ELEMENT GD PLUS Glow Discharge Mass Spectrometer. Defining quality standards for the analysis of solid samples

Chemical Analysis. PIONA+ Analyzer. Characterization of Engine Fuels by Hydrocarbon Group Type. Gas Chromatography. think forward

Thermo Finnigan LTQ. Specifications

FT-ICR Mass Spectrometer QUANTRA. Technical Description September quantra

Innovative Thermal Desorption From Agilent Technologies. Vivek Dhyani Application Chemist

QuantumMCA QuantumNaI QuantumGe QuantumGold

A DIVISION OF ULVAC-PHI. Time-of-Flight Secondary Ion Mass Spectrometer with Parallel Imaging MS/MS for Confident Molecular Identification

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW

Multi-residue analysis of pesticides by GC-HRMS

Thermo VG PQ EXCELL INDUCTIVELY COUPLED PLASMA MASS SPECTROMETER

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer

High Pressure DSC Differential Scanning Calorimeter

CONFOCHECK. Innovation with Integrity. Infrared Protein Analysis FT-IR

SIFT-MS SELECTED ION FLOW TUBE MASS SPECTROMETRY TECHNOLOGY OVERVIEW

Atomic Absorption Spectrometer ZEEnit P series

Bruker Daltonics. EASY-nLC. Tailored HPLC for nano-lc-ms Proteomics. Nano-HPLC. think forward

Thermo Scientific LTQ Orbitrap Velos Hybrid FT Mass Spectrometer

TGA Thermal Gravimetric Analysis

Thermo Scientific ConFlo IV Universal Interface. Continuous Flow Interface. Isotope Ratio MS

Quadrupole Time-of-Flight Liquid Chromatograph Mass Spectrometer LCMS-9030 C146-E365

Pulsar. Delivering NMR to your benchtop

Modern Methods in Heterogeneous Catalysis Research: Preparation of Model Systems by Physical Methods

The Claviature of Gas Analysis

Applications of ICP-MS for Trace Elemental Analysis in the Hydrocarbon Processing Industry

Agilent All Ions MS/MS

NON-METHANE ORGANIC CARBON ANALYZER (NMOC Method 25)

All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems

Courtesy of ESS and TheRGA web pages part of a series of application and theory notes for public use which are provided free of charge by ESS.

EGASUS. 4D GCxGC TOFMS. Delivering the Right Results

costech instruments ECS 4010 Elemental Combustion System CHNS-O

Cover Page. The handle holds various files of this Leiden University dissertation.

Thermal Analysis Mass Spectrometer Coupling. Evolved Gas Analysis Method, Techniques and Applications

AutoChem II 2920 The Cayalyst Characterization Laboratory

ICP-3000 Inductively Coupled Plasma Optical Emission Spectrometer

Automation of the radiochemical procedures for the sequential separation of radionuclides

Translational Biomarker Core

Mercury Stack Monitor SM-4

Thermo Scientific K-Alpha + XPS Spectrometer. Fast, powerful and accessible chemical analysis for surface and thin film characterization

Agilent s New 8800 ICP-QQQ. Transforming ICP-MS Technology

Whole Tablet Measurements Using the Frontier Tablet Autosampler System

FSA TM Multi-bit Digital Processors

MM 2. Innovation with Integrity. The new Generation of Mobile Mass Spectrometers. Defence CBRNE

Vacuum Pumps. Two general classes exist: Gas transfer physical removal of matter. Mechanical, diffusion, turbomolecular

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment

Whole Tablet Measurements Using the Spectrum One NTS Tablet Autosampler System

ActiPix SDI300 Surface Dissolution Imaging System

Live Webinar : How to be more Successful with your ACQUITY QDa Detector?

High Throughpu[ Separations and Structural Information Achieved with Automated LC/MS. Michael P. Balogh, Matthew J. Dilts Waters Chromatography

Direct Analysis of Trace Metal Impurities in High Purity Nitric Acid Using ICP-QQQ

Hiden Isochema IMI Series. Manometric Gas Sorption Analyzers.

Humidity Calibration Solutions

Introduction to the Q Trap LC/MS/MS System

Analytical Instrumentation

Relative Sensitivity RS Measurements of Gases

Guide to Peptide Quantitation. Agilent clinical research

MassHunter TOF/QTOF Users Meeting

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment LCQ Deca XP Plus

Transcription:

CATALYSIS & THERMAL ANALYSIS MASS SPECTROMETERS FOR CATALYSIS & THERMAL ANALYSIS

HIDEN MS CONTENTS MASS SPECTROMETERS for Catalysis and Thermal Applications Hiden Analytical have been designing and developing the highest quality quadrupole mass spectrometer based gas analysis systems for over 30 years. We have built a reputation for delivering instruments with superior sensitivity, accuracy and reproducibility together with a first class global service and applications support network. From dedicated triple filter UHV TPD quadrupoles to fully integrated catalysis microreactor and mass spectrometer systems, Hiden have developed a range of analytical mass spectrometers that address the most advanced and demanding applications. CONTENTS Catalysis and Thermal Analysis: CATLAB automated microreactor/ms system QIC Series for gas analysis Spaci-MS spatially resolved capillary inlet MS TPD Workstation complete UHV TPD system HPR-20 QIC TMS transient MS for fast event gas analysis TA-MS for evolved gas analysis UHV TPD for fast event UHV studies HPR-60 MBMS molecular beam sampling mass spectrometer Software: Thermal Analysis Software application specific software QGA Professional for quantitative gas and vapour analysis MASsoft Professional control software Hiden Applications

CATLAB QIC SERIES CATLAB Automated Microreactor/MS System QIC SERIES for Gas Analysis The Hiden CATLAB is a bench-top microreactor and The Hiden QIC Series Gas Analysers are a range of combined mass spectrometer system for rapid and realtime bench-top mass spectrometers for monitoring reproducible catalyst characterisation and reaction evolved gases and vapours across the pressure range studies. The microreactor and mass spectrometer are 100 mbar to 2 bar. Mass range options are 200 amu, delivered as a complete system from a single 300 amu, 510 amu and 1000 amu with an ultimate manufacturer, unique to the industry, ensuring optimum detection limit of 5 ppb. analysis via seamless hardware and software integration. The modular design further allows both instruments to They are offered with a wide range of interfaces for operate as stand-alone components so that they may be interfaced with existing laboratory equipment such as TGAs (TG-MS) or Gas Chromatographs. CATLAB microreactor module QGA bench-top gas analyser connection to thermal analysis equipment such as TGAs or tube furnaces and all components are designed to be user serviceable. The Hiden CATLAB delivers a range of completely Each analyser is configured with Hiden s heated Quartz automated, dynamic, temperature programmed, pulse Inert Capillary (QIC) inlet for continuous sampling of chemisorption and isothermal techniques. Template driven permanent gases and vapours with a response time of CATLAB software provides automatic control of gas less than 300 ms. composition and delivery, temperature ramp and set-point as well as full mass spectrometer parameter controls a true first for the catalyst researcher. The standard system has 0-200 amu capability with options extending this to 1000 amu. MID trace A choice of pumping options (independent or combined foreline and bypass pumping) for different applications allows the inlet flow rate to be chosen over the range 1 sccm to 20 sccm for matching to specific outlets and gas compositions. The high sample throughput and CATLAB software unique design virtually eliminates the incidence of blockages compared with other inlet types. The fast response and recovery of the QIC inlet to vapour species far exceeds conventional capillary inlets making these CATLAB data display APPLICATIONS: temperature programmed desorption (TPD) temperature programmed reduction/oxidation (TPR/O) temperature programmed reaction (TPRx) pulse chemisorption quantitative data output simultaneous detection of more than 100 species from internal library soft ionisation mode for reducing fragmentation analogue inputs for logging external signals, e.g. temperature and pressure analysers ideal for TPD, TPR/O and TPRx studies as well as continuous monitoring of reaction processes. pulse calibration dispersion measurements multiple I/Os for data synchronisation with external events adsorption isotherms reaction studies OPTIONS: control of external devices e.g. MFCs, temperature controllers heated inlet particulate filter multiport sampling valve HPR-20 QIC R&D Plus

SPACI-MS TPD WORKSTATION SPACI-MS Spatially Resolved Capillary Inlet MS TPD WORKSTATION Complete UHV TPD System The Hiden Analytical spatially resolved capillary inlet MS The Hiden TPD Workstation is a complete experimental (Spaci-MS) is the first commercially available instrument system for UHV temperature programmed desorption of its kind. Recipient of a R&D 100 award, the Spaci-MS (TPD) studies. The TPD Workstation features a multiport inlet was originally conceived and developed by UHV chamber with heated sample stage coupled to a high researchers at the Oak Ridge National Laboratory and precision triple filter analyser with digital pulse ion Cummins, Inc. to study diesel catalysis (1) and has been counting detector for ultimate sensitivity and time further developed for a whole range of applications. resolution. The triple filter mass analyser is configured with a cooled shroud giving minimum outgassing with Spaci-MS allows both radial and axial species determination and temperature profiles, with high spatial and temporal resolution and with negligible interference in flow or temperature. The 16 channel multi-inlet is coupled to Hiden s fast transient MS (HPR-20 QIC TMS) to provide automatic and rapid mapping of temperature and species Intra-catalyst sampling of gas and temperature TPD Workstation viewport optimum sensitivity of the analyser to desorption products from the sample. A fast sample load lock with sample transfer mechanism is included to provide for rapid sample change. Hiden s TPDsoft thermal analysis PC software included distributions. with the Workstation provides automatic control of sample temperature integrated with analyser control. TPD analysis Up to 16 capillary sampling probes and thermocouples are arranged in an X-Y array. A Z-shift provides movement and accurate positioning of the array in the Z plane. In usual practice, the 16 capillary sampling probes are routines (e.g. peak integration, deconvolution and background subtraction etc.) are also included in this package. sequentially analysed by the MS. The Z-shift is then actuated to move the sampling probe array to the next incremental Z position and the analysis sequence is Spaci-MS sample holder repeated. On completion the analytical data provides a spatial representation of temperature and sample gas TPDsoft for control and analysis of TPD experiments composition of the volume enclosed within the X-Y array over the total incremental Z distance moved. Ref: 1 Partridge, W.P. et al. Journal of Fuels & Lubricants, 2000, 109, 2992-2999 quantifies intra-catalyst-channel species transients and distributions high temporal resolution minimally invasive Hiden 3F PIC mass spectrometer for fast data acquisition (> 500 data points per sec) multiport UHV chamber for attachment of additional instrumentation (e.g. ellipsometry) APPLICATIONS: fuel cell studies sample transfer mechanism and load lock, including gate valve and viewport diesel engine catalysts heated sample stage to 1000 C air exhaust mixing systems Z-drive for optimum sample/detector positioning Spaci-MS non-thermal plasma reactors bakeout jacket (200 C max) integrated software control of experimental protocols TPD Workstation

HPR-20 QIC TMS TA-MS HPR-20 QIC TMS Transient MS for Fast Event Gas Analysis TA-MS for Evolved Gas Analysis The Hiden HPR-20 QIC TMS (Transient Mass The Hiden HPR-20 QIC EGA gas analysis system is Spectrometer) is designed specifically for fast transient configured for continuous analysis of evolved gases and gas analysis at near atmospheric pressure making it ideal vapours from thermogravimetric analysers (TGA). Custom for analysis techniques such as SSITKA (Steady State designed interfaces are available for special requirements Isotopic Transient Kinetic Analysis) where a very fast with alternative systems being offered for applications response is desired. The TMS features a 0.9 m QIC requiring direct sampling from advanced quartz-lined sampling interface and optimised pumping thermogravimetric analysers operating at higher configuration. The inlet, operating at 200 C, provides pressures of up to 30 bar. response times of less than 150 ms to changes in gas composition with a 5 decade response time in < 200 ms. The inlet is coupled directly to Hiden s 3F PIC (pulse ion counting) digital MS which is capable of measurement speeds of over 500 data points/sec over the entire 7 decade dynamic range. HPR-20 QIC TMS transient MS QIC inlet HPR-20 QIC EGA All of Hiden s QIC series gas analysers may additionally be equipped with fast response, low dead volume interfaces for the most popular TGA equipment. Each interface has been custom engineered in collaboration with TGA manufacturers (e.g. PerkinElmer, TA Instruments, Setaram, Netzsch etc.) and includes, Data acquisition can be triggered and synchronised by the where necessary, robust clamping arrangements and gas pulse signal via the on-board and comprehensive in-line heated filter assembly between the outlet of the range of I/O facilities of the MS. TGA and the MS capillary inlet. EGAsoft is an application specific software package for use in TA-MS applications with features such as 3D bar scan view mode, export to specific file types for import to CO 2 breath analysis, 700 data points per second EGAsoft TGA manufacturers software and NIST export for database searching of unknowns. fast response inlet < 150 ms minimum dead volume 5 decades < 200 ms HPR-20 transient MS data > 5 decades response in < 200 ms fast data acquisition, > 500 data points/sec wide dynamic range, 7 decade continuous log scale 5 decade response in < 200 ms synchronised data acquisition via TTL inputs controllably heated sample inlet no cold spots inert materials high performance gas handling for operation with low molecular weight gas components (H 2,He) and for flow matching with the TGA TGA-MS plot

UHV TPD HPR-60 MBMS UHV TPD for Fast Event UHV Studies HPR-60 MBMS Molecular Beam Sampling Mass Spectrometer Hiden s 3F PIC Series Quadrupoles are high precision The Hiden HPR-60 molecular beam mass spectrometer is triple filter analysers with digital detectors for ultimate a compact skimmer inlet MS for the analysis of reactive sensitivity and time resolution in fast event studies such gas phase intermediates. Radicals are sampled via a as UHV TPD. 3F Series analysers are available with UHV multistage differentially pumped skimmer inlet and compatible mass filter shrouds and low profile ion source transferred to the MS ion source with minimal interaction for close positioning to the desorption surface. with other species and without wall collisions. Customisable inlets allow connection to many different Both analogue and digital inputs are provided for reactor systems. synchronous acquisition start and sample temperature data display alongside mass channel data. The skimmer system, combined with a Hiden triple filter precision mass spectrometer, offers a sampling system Application specific software and external device program Molecular beam inlet with ultra fast response and high accuracy. protocols (RS485, Modbus) enable the user to control temperature ramp profiles and collect data in the same program (TPDsoft) or to simply collect MS data and temperature in the same program (EGAsoft). 3.0x10-10 State II Intensity (c/s) 1.0E+07 1.0E+06 1.0E+05 1.0E+04 H3O + O2 + n=1 n=2 n=3 n=4 n=5 n=6 n=7 2.5x10-10 3F PIC 1.0E+03 1.0E+02 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 mass (a.m.u.) 43 amu Signal 2.0x10-10 1.5x10-10 Multilayer Hydrated cluster ions from atmospheric dielectric barrier discharge 1.0x10-10 State I 5.0x10-11 0.0 150 200 250 300 350 400 Temperature [K] low profile ion source fast data acquisition > 500 data points per second wide dynamic range molecular beam sampling at atmospheric pressure +ve and -ve ion analysis user replaceable skimmer cones TPD Plot courtesy of M. Kadodwala (University of Glasgow, UK) 7 decade continuous log scale gating input for pulsed gas studies down to 100 ns gating resolution mass range options: 300, 510 or 1000 amu APPLICATIONS INCLUDE: catalytic reactors Range of shrouds reaction kinetics study of transients HPR-60 MBMS plasma chemistry

SOFTWARE SOFTWARE THERMAL ANALYSIS SOFTWARE Application Specific Software for Data Acquisition and Control THERMAL ANALYSIS SOFTWARE Application Specific Software for Data Acquisition and Control A range of software packages are available for data CATLAB Software acquisition and control of other devices for more integrated experimental procedures. Three software packages are available depending on the level of integration required. For use with the Hiden Microreactor system. Controls MS data acquisition alongside other devices such as MFCs, furnace temperature, switching valves etc. The software can also be used with existing compatible furnace All feature a simple MS interface for Bar or MID scan setup, 3D bar scan data viewing for identification of systems when supplied with the Hiden Gas Control unit and a suitable Eurotherm controller. desorption trends and peak integration/deconvolution functions. CATLAB software The software controls the experiment by following a temperature profile defined by the user. This profile is then EGAsoft For use with thermal analysis equipment (TA-MS) e.g. TGA/DSC systems or Hiden Mass Spectrometers coupled to external reactor/furnace systems. The software features inputs for temperature signals and simple EGAsoft main screen used to trigger changes in gas composition, inject pulses of gas and start/stop MS analysis files. Different analysis files can be configured for different parts of the experiment ensuring the MS is always configured with the optimum settings for that part of the experiment. start/stop triggering from external devices where A number of data analysis routines are included in the available. In addition automatic exports to TGA software for determination of catalyst properties such as manufacturers software packages are available. MS metal surface area, dispersion and pulse adsorption analyses can be configured in stages triggered by 2D bar scan mode isotherms etc. start/stop signals for use with TGA autosamplers. TPDsoft TPDsoft software For use with the Hiden TPD workstation or for users of a Hiden MS in conjunction with a compatible Eurotherm controller (e.g. model 2416, RS485, Modbus Enabled) for simple MS setup and control APPLICATIONS: TA-MS heater/furnace control. A ready configured temperature control unit is also available from Hiden. The software controls a temperature profile on to which MS measurement stages can be added. MS measurement 3D bar scan view peak integration/deconvolution automatic overlap removal catalysis UHV TPD off gas analysis MID scan mode stages are triggered by temperature or time depending on where in the temperature profile the scan is placed. This allows complete control of a TPD experiment in one custom export formats for NIST, TA Instruments, PerkinElmer, Setaram etc. TPD/R/O software package for easy synchronisation of MS data and temperature signal. external temperature inputs automatic MS trigger Peak integration/deconvolution

QGA MASsoft Pro QGA PROFESSIONAL for Quantitative Gas and Vapour Analysis MASsoft PROFESSIONAL Control Software QGA Professional Edition software is an application specific software package for quantitative gas and vapour analysis providing realtime continuous analysis of up to 16 species with species concentration measured in the range 0.1 ppm to 100 %. The software can be used in either single stream mode or multi-stream mode for use with multi-stream gas selection valves with up to 80 streams. The software features easy to use calibration routines for both cracking pattern and Relative Sensitivity (RS) measurement. Analysis is performed using simple template setup routines and features automatic spectral overlap removal algorithms and correction factor determination to output quantitative data. Integrated inputs from external devices such as CO analysers make the software versatile for a whole range of gas analysis applications. QGA Professional main screen Trend analysis (MID) setup All Hiden instruments are supplied with MASsoft Professional mass spectrometer control software. MASsoft Professional is a multilevel software package allowing both simple control of mass spectrometer parameters and complex manipulation of data and control of external devices. Quick start tabs with user configurable single key start functions means novice users can start collecting data within seconds. Scan templates allow fast set up of scans from previous similar experiments. Automatic mass spectral analysis setup Scan gallery Spectra view quantitative gas analysis of up to 16 gases 10 peak spectral library with intelligent library scan feature component gas calibration with background correction automatic triggering of analysis from an external input read multiple inputs, temperature or pressure for example x-axis can display time or an external input, e.g. temperature full control of the mass spectrometer ion source enables soft ionisation of complex organics, and appearance potential mass spectrometry for simplification of complex spectra export data to NIST mass spectral database for comprehensive analysis of unknowns export to external data analysis software, e.g. Excel, Origin contro l of external devices, e.g. mass flow controllers, gas switching/sampling valves and furnace temperature controllers output data as percentage or ppm files realtime subtraction of overlapping peaks for quantitative measurements MASsoft Professional - overview

HIDEN APPLICATIONS Hiden s quadrupole mass spectrometer systems address a broad application range in: Gas Analysis Surface Science Plasma Diagnostics Vacuum Analysis dynamic measurement of reaction gas streams catalysis and thermal analysis molecular beam studies dissolved species probes fermentation, environmental and ecological studies UHV TPD SIMS end point detection in ion beam etch elemental imaging surface mapping plasma source characterisation etch and deposition process reaction kinetic studies analysis of neutral and radical species partial pressure measurement and control of process gases reactive sputter process control vacuum diagnostics vacuum coating process monitoring quadrupoles for advanced science Hiden Analytical Ltd. 420 Europa Boulevard Warrington WA5 7UN England Tel: +44(0)1925 445225 Fax: +44(0)1925 416518 Email: info@hiden.co.uk Web: Certificate No: 6738 TECHNICAL DATA SHEET 166/2 Hiden Analytical E & O E