Preparation of Food and Feed Samples for Metals Analysis

Similar documents
Basic Digestion Principles

Analysis of trace elements in polymer samples to ensure compliance with WEEE-RoHS standards using the Thermo Scientific icap 7200 ICP-OES

METHOD 3010A ACID DIGESTION OF AQUEOUS SAMPLES AND EXTRACTS FOR TOTAL METALS FOR ANALYSIS BY FLAA OR ICP SPECTROSCOPY

RISK ASSESSMENT, IMPLEMENTATION AND VALIDATION OF ELEMENTAL IMPURITIES FOR ICH Q3D, USP <232><233> AND EP 5.20

Current State of Extraction Don t Be Deceived! Sharon F. Webb, Ph.D. Director of Quality Program

Colorimetric Method Method to 0.70 mg/l Ag Powder Pillows

OPTIMIZING METALS SAMPLE PREP

5072 CHEMISTRY (NEW PAPERS WITH SPA) TOPIC 1: EXPERIMENTAL CHEMISTRY 5067 CHEMISTRY (NEW PAPERS WITH PRACTICAL EXAM) TOPIC 1: EXPERIMENTAL CHEMISTRY

The Determination of Toxic, Trace, and Essential Elements in Food Matrices using THGA Coupled with Longitudinal Zeeman Background Correction

METHOD 7060A ARSENIC (ATOMIC ABSORPTION, FURNACE TECHNIQUE)

Accurate measurement of elemental impurities in metals and metal alloys using the Thermo Scientific icap TQ ICP-MS

Multi-Element Analysis of Petroleum Crude Oils using an Agilent 7900 ICP-MS

PROCEDURES. Pharmacopeial Forum 2 Vol. 36(1) [Jan. Feb. 2009]

Trace elemental analysis of distilled alcoholic beverages using the Agilent 7700x ICP-MS with octopole collision/ reaction cell

á233ñ ELEMENTAL IMPURITIES PROCEDURES

IMPROVED ADIABATIC CALORIMETRY IN THE PHI-TEC APPARATUS USING AUTOMATED ON-LINE HEAT LOSS COMPENSATION

Tex-620-J, Determining Chloride and Sulfate Contents in Soil

Pharmacopeial Forum Vol. 36(1) [Jan. Feb. 2010] 1

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. NY/T Translated English of Chinese Standard: NY/T

Simple, reliable analysis of high matrix samples according to US EPA Method 6020A using the Agilent 7700x/7800 ICP-MS

Key Analytical Issues: Sample Preparation, Interferences and Variability. Tim Shelbourn, Eli Lilly and Company

BATTERY INDUSTRY STANDARD ANALYTICAL METHOD

In terms of production, nitric acid is the third most widely produced acid across the world.

CONTINUOUS FLOW CHEMISTRY (PROCESSING) FOR INTERMEDIATES AND APIs

Determinations by Atomic Absorption Spectroscopy and Inductively Coupled Plasma-Atomic Emission

Today s Agilent Solutions for Determining Heavy Metals in Food using Atomic Spectroscopy

Direct Measurement of Metallic Impurities in 20% Ammonium Hydroxide by 7700s/7900 ICP-MS

Handbook of Inductively Coupled Plasma Spectrometry

Mercury, membrane or diaphragm

Test Method: CPSC-CH-E

The early periodic table

3.2.6 Group II. Trends in Chemical properties. 164 minutes. 161 marks. Page 1 of 19

JRP SIB09 Elements GOOD PRACTICE GUIDE ON DEALING WITH INTERFERENCES IN ICP-MS FOR INVESTIGATING HIGH PURITY MATERIALS. Deliverable 1.2.

Rapid Sample Assessment and Simplified Method Development with IntelliQuant

Techniques for the Analysis of Organic Chemicals by Inductively Coupled Plasma Mass Spectrometry (ICP-MS)

Worksheet 1.1. Chapter 1: Quantitative chemistry glossary

Atomic Absorption Spectrophotometry. Presentation by, Mrs. Sangita J. Chandratre Department of Microbiology M. J. college, Jalgaon

atomic absorption spectroscopy general can be portable and used in-situ preserves sample simpler and less expensive

4 Examiner SECTION B. Answer all questions in the spaces provided. 5. (a) The Solvay process is used to make sodium compounds from sodium chloride.

COMPARISON OF ATOMIZERS

Year 10 Chemistry Exam June 2011 Multiple Choice. Section A Multiple Choice

Enhancing the productivity of food sample analysis with the Agilent 7700x ICP-MS

2101 Atomic Spectroscopy

Procedure for determining the activity concentration of airborne particulate radium-226

Multi Analyte Custom Grade Solution. Calcium, Iron, Potassium,

Results of the 18 th and 19 th Needle/Leaf Interlaboratory Comparison Tests

Title Revision No date DETERMINATION OF HEAVY METALS (ARSENIC, CADMIUM, LEAD AND MERCURY) IN COSMETIC PRODUCTS

Solvothermal Technique Guidelines

For the element X in the ionic compound MX, explain the meaning of the term oxidation state.

METHOD 8033 ACETONITRILE BY GAS CHROMATOGRAPHY WITH NITROGEN-PHOSPHORUS DETECTION

Proficiency Test Report

In the early version of the periodic table (by Newlands and then Mendeleev), how were the elements arranged?

C2 Revision Pack (Please keep this pack with you)

Multi-Element Analysis of Cannabis using the Agilent 7800 ICP-MS

CHEMICAL EQUILIBRIA. Section A Q1 The dissociation of dinitrogen tetraoxide into nitrogen dioxide is represented by the equation below.

Chemical Reactions and Equilibrium Acid/Bases Redox. Revision What is a chemical reaction? What factors affect the rate of reaction?

Exploration with LA-ICP-MS: Know Your Dirt

Q1. Ammonia is used in the production of fertilisers. The flow diagram shows the main stages in the manufacture of ammonia.

The challenges of field sensors for trace metal detection. Chris Searle Product Manager Trace2o Ltd

Application note. Trace level analysis of sulfur, phosphorus, silicon and chlorine in NMP using the Agilent 8800 Triple Quadrupole ICP-MS

Prof. Dr. Biljana Škrbić, Jelena Živančev

GENERAL INSTRUCTIONS GENERAL PREPARATION

Mixing ratios of gases can also be expressed in ppvb, parts per billion (10 9 ) by volume.

Glossary of Common Laboratory Terms

Determination of Nutrients. Determination of total phosphorus. Extraktion with aqua regia, reflux method. Introduction

Unit 4: Chemical Changes (Higher Content)

Determination the elemental composition of soil samples

Sodium Chloride - Analytical Standard

Matter and Its Properties

Determination of Total Bromine and Iodine Emission Spectrometric Method (ICP-OES) EuSalt/AS

Smith-Palmer Chemistry 265 Analytical and Environmental 2010

2.3 Group 7 The Halogens

Determination of trace elements in ultrapure semiconductor grade sulfuric acid using the Agilent 8900 ICP-QQQ in MS/MS mode

ICSE Board Class X Chemistry Board Paper Time: 1½ hrs Total Marks: 80

Cited from Vogel s Textbook of Quantitative Chemical Analysis, 5th ed., G.H. Jeffery.

Inside the Black Box of an Environmental Testing Laboratory Basic Analytical Procedures

Physical and Chemical Changes. 3. One of the new materials was a precipitate that settled out of solution.

Background Statement for SEMI Draft Document 5324 NEW STANDARD: GUIDE FOR CYCLOPENTANONE

TECHNICAL BRODIFACOUM

Application Note PlasmaQuant PQ 9000 Elite, PlasmaQuant MS Elite

Determination of major, minor and trace elements in rice fl our using the 4200 Microwave Plasma- Atomic Emission Spectrometer (MP-AES) Authors

Determination of Impurities in Silica Wafers with the NexION 300S/350S ICP-MS

GPS summary for Sodium Hypochlorite CAS: Brzeg Dolny

Chemical Reactions: The Copper Cycle

ICSE Board. Class X Chemistry. Board Paper Time: 1½ hrs Total Marks: 80

1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:


INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY

Anhydrous strontium chloride is not used in toothpaste because it absorbs water from the atmosphere. The hexahydrate, SrCl 2.6H 2O, is preferred.

Determination of Trace Metals in Human Urine Using the NexION 300 ICP-MS

Classification of Mystery Substances

9.1.2 AQUEOUS SOLUTIONS AND CHEMICAL REACTIONS

Proposed new USP general chapters <232> and <233> for elemental impurities: The application of ICP-MS for pharmaceutical analysis

Chemical Names and Formulas

GENERAL INSTRUCTIONS GENERAL PREPARATION

Procedure for determining the specific activity of radium-226 in foodstuffs of plant origin

Product Safety Reference Manual. Book 5 - Laboratory Policies and Procedures C

# Ans Workings / Remarks

Transcription:

White Paper Preparation of Food and Feed Samples for Metals Analysis Alan Cross Technical Specialist, Metals Laboratory

Preparation of Food and Feed Samples for Metals Analysis The relative virtues of ICP-MS, ICP-OES and AAS have been frequently discussed, in terms of their use for the analysis of metals, either from a nutritional aspect, but also as control of contamination in food materials. However, sample preparation is often overlooked as an important aspect of the analysis of food samples, yet it is as critical, if not more so than the analytical technique itself. After all, if the sample is not prepared properly, any subsequent analysis will be compromised. There are great variety of possible analytical techniques to choose from when considering sample preparation, namely direct analysis, dissolution in aqueous or organic solvents, open vessel digestion, closed vessel digestion and ash digestion. Each of these techniques has its own advantages and disadvantages. In an ideal world, all samples would be in a state that meant they could be aspirated directly into the instrument for analysis. If this were possible there would be no danger of losing volatile analytes, of sample contamination or of worries about detection limits due to dilution of the sample, as discussed in this white paper. Unfortunately samples rarely come in this condition, and even if they do, there are other factors to consider that may mean that analysis is not necessarily simple. Nonetheless, direct analysis is sometimes an option. Direct analysis One big consideration for this technique is the effect of total dissolved solids (TDS). Plasma techniques (i.e. ICP) and flame techniques (i.e AAS) are particularly sensitive to TDS and so the presence of these can be detrimental to the quality of the analysis. Obviously tolerance to TDS varies greatly on instrument set-up, and different configurations of nebulisers and spray chambers can be used to optimise conditions. As an approximate guide, ICP-OES and AAS techniques are more tolerant of TDS, with levels of 5% being routinely accommodated. In some special cases, levels of up to 20% can be tolerated. ICP- MS on the other hand is more vulnerable to interference from TDS, with a maximum level of around 0.2% being acceptable. With a direct analysis approach, the level of TDS will often be higher than one would find in a prepared sample. These effects can be mitigated by simple dilution with the aim of minimising TDS levels, and, of course, this option is available for all sample preparations. Another consideration of analysing direct samples is the effect of organic material on the behaviour of the plasma. As the organic material is consumed within the plasma, the chemistry alters, which often causes a shift in the ionisation equilibrium, thereby affecting the behaviour of the analytes. This phenomenon is particularly marked for analytes such as arsenic and selenium (due to the high ionisation potentials for these elements), but can be overcome by the addition of an appropriate amount of an organic solvent such as methanol or acetic acid to the calibration standards in an attempt to matrix match the samples to standards. There may also be a variety of instrumental variations, such as addition of oxygen to the plasma, or use of gas-mode analysis, which can overcome these problems. Another practical option is to carry out a standard addition calibration, where the calibration solution is added to the sample and the concentration of analyte is extrapolated from the obtained values. In any case the conditions for analysis should be evaluated as a part of any feasibility testing. Dissolution As mentioned above, dissolution of the sample is the next possibility for sample preparation. This technique again has similar considerations as direct analysis, but in a way can be a lot more controlled as the same solvents can easily be used for the sample and standards, thus negating the problems of unmatched matrices. Again, there will have to be a certain level of compromise with the dissolution of the sample to ensure the level of TDS is acceptable for the analysis technique used, whilst making sure that the analyte (if present) is measurable and above the level of quantitation (LOQ) of the instrument. To put it simply, dilution might push the elements of interest below the limit of detection of the instrument. Direct analysis and dissolution techniques are the simplest to employ, but due to the complex nature of most food materials they can rarely be used, often a more vigorous preparation will be required. Open vessel digestion This is technically one of the simplest preparations for more complex matrices. An aliquot of sample, typically between 0.5-2g is taken into a cleaned vessel and nitric acid is added and the solution boiled, the heat and the strong oxidising nature of the acid will start to destroy the organic material in the sample, releasing metal ions into free solution. Once reaction is complete the resulting solution can be made to volume and analysed. As the conditions for the sample digest are not as intense as those experienced in a closed vessel system, there may be significant amounts of organic material left in the sample solution, this must be considered when the analysis technique is being decided, and some matrix matching may be necessary for the plasma techniques, though these samples will fare better in an AAs. One of the main disadvantages is the fact that an open vessel being used will allow some elements such as arsenic and mercury to lost through volatilisation. Ash digestion This technique is widely used for the preparation of food samples, generally for subsequent analysis by flame photometry or AAS. A sample of 1 10g is taken into a crucible (made from a range of materials such as alumina, silica or porcelain). The sample is then slowly charred to remove the majority of organic material, then placed into a furnace at high temperatures (typically around 600 C) to destroy the Page 2

organic material in the samples, leaving only the mineral content which can then be dissolved and analysed. Often in food analysis an ash weight is recorded as part of the analysis of the material, so this technique for preparation is useful as this preparation is also part of the testing. Though useful for the analysis of nutritional elements such as sodium and calcium, its use is generally restricted to analysis by AAS and not commonly used for ICP analysis. Also due to the high temperature in an open vessel that the samples are exposed to, this technique would not be suitable for volatile element analysis. Closed vessel digestion In the case of insoluble materials, closed vessel digestion will be required to destroy the sample matrix. This technique is especially valuable when analysing complex materials, final products and even food additives such as colourants and premixes. Microwave digesters are commonly used to perform the digestion as these are easy to use and can rapidly process many samples at a time. There are many different types of microwaves available on the market, each with their own advantages and disadvantages. Typically, an aliquot of sample between 0.1 0.5g will be placed into a polytetrafluoroethylene (PTFE) or glass vessel along with acids. PTFE vessels will then be sealed with a tight fitting cap to create a pressurised environment, whereas glass vessels will be loosely covered and placed into a chamber which is then pressurised to generate the digestion environment. Once samples are digested, the digestate is transferred to a volumetric vessel and made to the required volume using high purity water. If digestion is effective then the matrix effects from organic material should be sufficiently removed by oxidisation (to carbon dioxide and water). Though the organic matter is effectively destroyed by the microwaving process there may still be TDS considerations to be taken into account, as these will not be destroyed by the microwaving process. This is an important consideration when planning on the sample size and final preparation volume. The choice of acids used for the preparation of digested samples is also important. Typically nitric and hydrochloric acids are used for the preparation of these samples, often in combination with each other to optimise digestion conditions. The presence of hydrochloric acid is useful for stabilisation of platinoid group elements, but can sometimes cause unwanted side reactions (e.g. formation of insoluble silver chloride). The presence of chloride in the final test solutions can also be detrimental, especially for ICP-MS as the chloride contributes to polyatomic interferences (most notably ArCl for As and Se). These polyatomic interferences can generally be removed by use of collision or reaction gases within the ICP-MS after the ions have been generated by the plasma. Nitric acid and peroxide are often used for organic matrices as the peroxide is an effective oxidising agent and destroys the organic matrix, but care must be taken when testing for osmium as this can form volatile osmium oxides in the oxidising atmosphere which are easily lost from the sample. In some cases hydrofluoric acid (HF) will have to be added to destroy certain materials such as titanium dioxide or silica if these have been used in the final product, or even if the excipient itself is being tested. In cases where HF is necessary, special instrumental adaptations need to be made to prevent damage to glass parts, either by direct replacement with PTFE materials or by use of specialist equipment that can generate a dry sample introduction. This preparation will also have an effect on the overall TDS levels, so it is important to consider this when looking at the preparation of these samples. Other techniques Obviously this is a very limited look at the available sample preparations, more an overview of the most likely methods for sample preparation. There are a huge variety of different options than can be used, but each must be carefully considered especially in terms of the preservation of analyte and minimisation of the effects of TDS and organic materials. There can be some situations where preparation is less critical. For example, x-ray microfluorescence (XRF) can be used for elemental analysis but suffers inasmuch as it has higher detection limits than that of the plasma techniques. However, a sample can be analysed directly with no preparation, this may be particularly applicable for the analysis of nutritional elements as these are likely to be present in high concentrations Another option is to use laser ablation to generate a vapour directly from the surface of the sample, which is then swept into an ICP-MS. Again this is a technique that does not require sample preparation. However, it is not commonly used as the samples need to be calibrated using standards of a similar material and these are generally not readily available. Specific considerations also apply to particular elements. When preparing samples for analysis of mercury, for example, care must be taken not to lose the analyte as it can be volatile. This is especially relevant when carrying out microwave digestion. That said, this volatility can be useful since there are mercury analysers on the market that measure levels by heating the sample and measuring the amount of mercury volatilised. These instruments are supremely practical as they can analyse the sample directly. That said, a single element technique is unlikely to be useful when used in isolation. In this overview, a brief critique of some of the sample preparation techniques that can be used for ICP and AAS analysis have been given. However, it must be said that it is important to evaluate both the preparation and analysis techniques together when considering how to assess elemental analysis requirements In some cases a food manufacturer may have the resource on site to carry out batch analysis for nutritional elements by use of flame photometry of AAS, but there may also be a requirement for analysis of low levels of certain elements as part of a due diligence program for example to monitor levels of lead or cadmium in raw materials, or traces of wear metals such as nickel or chromium in a final product. Page 3

This is where contract analysis laboratories may be a useful resource when considering testing regimes for food and food materials. They will generally be able to pull from a wide pool of knowledge and resource to efficiently optimise preparation and analysis conditions. They can also validate methods according to regulatory guidelines or company specific requirements. Once validated this method can be transferred back to be performed in-house or samples may be sent to the contract lab for routine analysis for batch release. Alan Cross - Technical Specialist, Metals Laboratory Alan graduated in 1999 from the University of Exeter with a Bachelor s Degree in Chemistry. He has worked across a variety of sectors including environmental, food, pharmaceutical and catalysis focusing mainly on analytical chemistry. During this time he covered a wide range of instrumental and wet chemistry techniques. Alan s main area of expertise is metals analysis covering ICP-MS, ICP-OES, AA and the related sample preparation such as microwave digestion and ash samples. For further information please contact Alan +44 (0)118 9184000 or alan.cross@rssl.com Page 4

Reading Scientific Services Ltd Reading Science Centre, White knights Campus, Pepper Lane, Reading Berkshire RG6 6LA, UK