Food analysis. Solutions for Your Analytical Business Markets and Applications Programs

Similar documents
ENVIRONMENTAL analysis

Multi-residue Analysis for PAHs, PCBs and OCPs on Agilent J&W FactorFour VF-Xms

Identification and Quantitation of PCB Aroclor Mixtures in a Single Run Using the Agilent 7000B Triple Quadrupole GC/MS

Highly Sensitive and Rugged GC/MS/MS Tool

Advantages of Reversed Sandwich Injection for Pesticide Residue Analysis

Application Note. Author. Abstract. Introduction. Hydrocarbon Processing

Trim Time Not Columns Multiresidue Pesticides Analysis with an Intuvo GC/TQ

A novel high resolution accurate mass Orbitrap-based GC-MS platform for routine analysis of Short Chained Chlorinated Paraffins

GC/MS/MS Dioxin and Dioxin-like PCBs in Feed and Food. Jessica Westland, LSAG Applications Chemist

Analysis of Biomarkers in Crude Oil Using the Agilent 7200 GC/Q-TOF

U.S. EPA Method 8270 for multicomponent analyte determination

Application Note No Introduction. DMI Instrumentation. DMI Method. DMI for Lettuce and Pea Extracts. Lettuce results

Determination of Organochlorine Pesticides and Polychlorinated Biphenyls Using GC/MS/MS Operated in the MRM Mode

DETERMINATION OF OCs, PCBs AND SYNTHETIC PYRETHROIDS IN ANIMAL FAT

Application Note. Abstract. Introduction. Determination of Polycyclic Aromatic Hydrocarbons in Seafood by an Automated QuEChERS Solution

materials analysis Solutions for Your Analytical Business Markets and Applications Programs

Pesticides Analysis Using the Agilent 5977A Series GC/MSD

Determination of Polycyclic Aromatic Hydrocarbons (PAHs) in Seafood Using GC/MS

Katherine K. Stenerson, Michael Ye, Michael Halpenny, Olga Shimelis, and Leonard M. Sidisky. Supelco, Div. of Sigma-Aldrich Bellefonte, PA USA

Technical Report. Abstract: Pu Wang 1, Huizhong Sun 1, Qinghua Zhang 1, Feifei Tian 2, Lei Cao 2

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

Author. Abstract. Introduction

Multi-residue analysis of pesticides by GC-HRMS

The Third Dimension of Information Vol. IV Applications with the Agilent Technologies Atomic Emission Detector. O H Cl. Fe Se

DETERMINATION OF RELATIVE FLUORESCENCE QUANTUM YIELD USING THE AGILENT CARY ECLIPSE

Cerno Bioscience MassWorks: Acquiring Calibration Data on Agilent GC/MSDs

Using Magnetic Sector GC-HRMS in a Commercial Dioxin Lab

Enhanced Sensitivity for Biomarker Characterization in Petroleum Using Triple Quadrupole GC/MS and Backflushing

METHOD 3600C CLEANUP

Application. Gas Chromatography March 1998

Sensitive Detection of Pyrethroids in Surface Water and Sediment

Hints and Tips for APGC Coupled with Xevo TQ-S for Food and Environmental Analysis

Results of a Sediment Survey in the Near Offshore Waters of the Proposed Quarry Site in the Vicinity of Whites Cove, Digby Neck, Nova Scotia

PAH Analyses with High Efficiency GC Columns: Column Selection and Best Practices

Self Cleaning Ion Source and other Innovations in Mass Spectrometry. Kirk Lokits (GCMS Applications Chemist) Blacksburg, VA February 2 nd, 2017

Gas Chromatography Mass Spectrometry (GCMS)

Yokogawa Analytical Systems Inc., Nakacho, Musashino-shi, Tokyo , Japan.

Determination of 17 Organotin Compounds in Beverages Using Triple Quadrupole GC-MS/MS System

Quantification of Pesticides in Food without Calibration using GC/FID with the Polyarc Reactor

An Optimal Method for the Analysis of Pesticides in a Variety of Matrices

Analysis of pesticide residues using various GC/MS systems. Radim Štěpán Czech Agriculture and Food Inspection Authority Prague, Czech Republic

Guidelines for the determination of persistent organic compounds (POPs) in seawater

A Direct 5 ms Column Performance Comparison for Active Semi-Volatile Analytes

ApplicationNOTE A STUDY OF THE ANALYSIS OF POLYBROMINATED DIPHENYL ETHER FLAME RETARDANTS BY GC/MS/MS. Introduction. Materials and Methods

Application Note. Authors. Abstract. Xin Sun Shandong Agriculture University, Taian, , China

Screening for Water Pollutants With the Agilent SureTarget GC/MSD Water Pollutants Screener, SureTarget Workflow, and Customized Reporting

MONITORING FOR PHARMACEUTICALS IN SURFACE WATER USING DIRECT AQUEOUS INJECTION ON THE AGILENT 6490 LC/QQQ

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

Application Note. Gas Chromatography/Mass Spectrometry/Food Safety. Abstract. Authors

METHOD 3600B CLEANUP

The Importance of Area and Retention Time Precision in Gas Chromatography Technical Note

Determination of Off-Odor Compounds in Drinking Water Using an SPME Device with Gas Chromatography and Mass Spectrometry

Determination of 198 pesticide residues in eggplant using Gas Chromatography tandem Mass Spectrometry/Mass Spectrometry

ApplicationNOTE Abstract

Automated Sample Preparation of Headspace Standards Using the Agilent 7696 WorkBench

Determination of Polybrominated Diphenylethers (PBDE) in Sediment and Sewage Sludge Application

PAL SPME Arrow The Better SPME

The Use of Tandem Quadrupole GC/MS/MS for the Determination of Polycyclic Aromatics Hydrocarbons (PAHs) in Food Products

Research of Polychlorinated Biphenyls (PCBs) in Vegetables by GC-MS/MS

high performance OPTIC 3 and applications a total analytical solution

Organochlorine Pesticides by GCxGC-ECD

What Is The Fastest Route to High Quality Data? AxION DSA: Quality data without chromatography or sample preparation. AxION 2 TOF MS and AxION DSA

Agilent 5977A Series GC/MSD System

Introducing the Agilent 7000A QQQ-MS for GC Sunil Kulkarni Product Specialist Agilent Technologies

Meeting Challenging Laboratory Requirements for USEPA Method 8270 Using a Highly Sensitive, Robust, and Easy-to-Use GC/MS

GC Analysis of Polybrominated Flame Retardants Application

Determination of 24 PAHs in Drinking Water

Derivatization Procedure and Negative Chemical Ionization GC/MS/MS Conditions for the Analysis of Steroidal Analogs

ApplicationNOTE THE ANALYSIS OF POLYCHLORINATED BIPHENYLS (PCBS) BY GC-HIGH RESOLUTION MASS SPECTROMETRY USING THE MICROMASS AUTOSPEC ULTIMA NT

Quantitative Determination of Dioxins in Drinking Water by Isotope Dilution using Triple Quadrupole GC-MS/MS

Application Note GCMS-01 Comparison of Ionization Techniques for the Analysis of Trace-Level Pyrethroid Insecticides by GC-MS/MS

Quantitative Analysis of Water-Soluble B-Vitamins in Cereal Using Rapid Resolution LC/MS/MS. Application. Authors. Abstract.

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

AppNote 6/2004. Thermal Desorption GC Analysis of High Boiling, High Molecular Weight Hydrocarbons SUMMARY

PAL SPME Arrow The Better SPME

Validation of GC-MS/MS for Detection and Confirmation of Low-Level Dioxins

Analysis of Opioids Using Isotope Dilution with GCMS-TQ8030 GC/MS/MS. No. GCMS No. SSI-GCMS-1401

Chemical Analysis. PIONA+ Analyzer. Characterization of Engine Fuels by Hydrocarbon Group Type. Gas Chromatography. think forward

Sensitive Detection of 2-MIB and Geosmin in Drinking Water

Workflow Using Hyphenated Mass Spectrometry Techniques

Agilent G3212 GC-APCI Source

Analysis of Ethanol and Isotopomers by 240 Quadrupole Ion Trap GC/MS

Chemical Analysis. Low Level Oxygenates Analyzer. Trace Analysis of Oxygenates in Hydrocarbon Matrices. Gas Chromatography.

The Analysis of Organophosphate Pesticides by LC/MS Application

Agilent 6460 Triple Quadrupole LC/MS System with an Agilent 1290 Infinity LC For Multi-Plant Growth Regulator Analysis in Grapes

Multi-residue GC-MS analysis. Richard Fussell CSL York, UK

Screening of Pesticide Residues in Water by Sequential Stir Bar Sorptive Extraction-Thermal Desorption with GC/MS

environmental Rtx -CLPesticides and Rtx -CLPesticides2 Columns: The Ideal Confirmational Pair for Analyzing Polychlorinated Biphenyls (PCBs)

A New Approach to the Analysis of Chlorinated Paraffins by Gas Chromatography Quadrupole Time of-flight Mass Spectrometry

[application note] INTRODUCTION EXPERIMENTAL. Specimens. Extraction

PCB Congener Analysis of XAD-2 Resins and GFF Filters Using GC/ECD

ISO INTERNATIONAL STANDARD. Soil quality Determination of organochlorine pesticides and. capture detection

Rugged GC/MS/MS Pesticide Residue Analysis Fulfilling the USDA Pesticide Data Program (PDP) Requirements

USEPA Methods 8270 and 8260 on a Single GCMS Without Changing Columns

Determination of Hormones in Drinking Water by LC/MS/MS Using an Agilent InfinityLab Poroshell HPH Column (EPA 539)

Rapid, Robust, and Sensitive Detection of 11-nor-D 9 - Tetrahydrocannabinol-9-Carboxylic Acid in Hair

Pittcon P

Facility: Mansfield Revision 3. Title: PAHs by SPME Page 1 of 11

The Suite for Environmental GC Analysis

Transcription:

Food analysis HIGH SENSITIVITY ANALYSIS OF TRACE ORGANIC POLLUTANTS IN MUSSEL TISSUE USING THE 7010 TRIPLE QUADRUPOLE MASS SPECTROMETER Solutions for Your Analytical Business Markets and Applications Programs Authors Praveen Kutty Technical Specialist Llanelli Laboratory Natural Resources Wales Chris Sandy GC/MS Product Specialist Agilent Technologies, UK ABSTRACT This Application Brief demonstrates the higher sensitivity achievable with the Agilent 7010 Triple Quadrupole GC/MS System for the analysis of Organo-chlorine pesticides (OCPs), Polyaromatic Hydrocarbons (PAHs) and Polychlorinated biphenyls (PCBs). INTRODUCTION In April 2011, Agilent Technologies published an application note [1] detailing the extraction and analysis of marine mussel tissue for the determination of trace levels of OCPs, PAHs and PCBs. The analysis employed the Agilent 7000B GC/MS/MS system for the routine monitoring of mussel tissue in accordance with the Clean Seas Environmental Monitoring Program (CSEMP) down to the required limit of detection (LOD) of 0.1 μg/kg. To comfortably achieve the required LOD, the analysis on the 7000B was performed using a 10 μl solvent vent injection. Agilent introduced the 7010 GC/MS/MS Instrument at ASMS in May 2014. The 7010 incorporates a novel EI High Efficiency Source (HES) and provides the lowest Instrument Detection Limit (IDL), proven at installation, of any GC/MS/MS system currently available. This Application Brief repeats the analysis documented in the 2011 Application Note and demonstrates a significant performance improvement when comparing the results from the 7000B to the Agilent 7010 Triple Quadrupole GC/MS System. Not only were like-for-like 10 μl solvent vent mode injections compared, but also 0.5 μl injections on the 7010 system using cold splitless injection mode.. GC/MS Configuration 7693A Automated Liquid Sampler 7890B gas chromatograph with CO2 cooled Multimode Inlet (MMI) and pressure controlled tee for post-column back flush Agilent 7010 Triple Quadrupole GC/MS System

Analysis Conditions Conditions were exactly as documented in the referenced application note. The only deviations were the conditions for the 0.5 μl cold splitless injections on the Agilent 7010 Triple Quadrupole GC/MS System: Injection volume : 0.5 μl from a 5 μl syringe Injection mode : Cold splitless Injection temperature : 50 deg C (0.02 minutes), then 600 deg C/min to 325 deg C RESULTS Comparative Responses To demonstrate the comparative performance of the 7000B and the Agilent 7010 Triple Quadrupole GC/MS System, the responses of the 0.4 pg/μl calibration standard injected on the 7000B (10μL solvent vent) and the 7010 (10μL solvent vent and 0.5μL cold splitless) for the quantitative transitions for the four HCH isomers; op- and pp-dde; PCB-153 and PCB-138; and Benzo(e)pyrene, Benzo(a)pyrene and Perylene are shown in Figures 1, 2, 3 and 4, respectively. Note that the analyte peaks elute a few seconds earlier on the 7000B system but this aids clarity for comparison purposes. Figure 1. Comparative responses of the 4 HCH isomers on the 7000B and Agilent 7010 Triple Quadrupole GC/MS System for the 0.4 pg/µl calibration standard. Figure 2. Comparative responses of op- and pp-dde on the 7000B and 7010 GC/MS/MS systems for the 0.4 pg/µl calibration standard. 2

Figure 3. Comparative responses of PCB-153 and PCB-138 on the 7000B and Agilent 7010 Triple Quadrupole GC/MS System for the 0.4 pg/µl calibration standard. Figure 4. Comparative responses of Benzo(e)pyrene, Benzo(a)pyrene and Perylene on the 7000B and Agilent 7010 Triple Quadrupole GC/MS System for the 0.4 pg/µl calibration standard. Comparative Calibration Curves Example calibration curves for g-hch, PCB-138 and Benzo(a)pyrene are shown in Figures 5, 6 and 7, respectively. The calibration curves for the 7000B are over the range 0.4 200 pg/µl (10µL solvent vent injection). For the 7010 the calibration curves are over the range 0.04 400 pg/µl (0.5µL cold splitless injection). Figure 5. Calibration curves for g-hch. 7000B calibration range 0.4 200 pg/µl; 7010 calibration range 0.04 400 pg/µl 3

Figure 6. Calibration curves for PCB-138. 7000B calibration range 0.4 200 pg/µl; 7010 calibration range 0.04 400 pg/µl Figure 7. Calibration curves for Benzo(a)pyrene. 7000B calibration range 0.4 200 pg/µl; 7010 calibration range 0.04 400 pg/µl 4

CONCLUSION Under directly comparative analysis conditions, the Agilent 7010 Triple Quadrupole GC/MS System gave responses in the order of 20x those obtained with the 7000B. For many analytes in this comparison, the response for the quantitative ion on the 7010 for a 0.5µL cold splitless injection was close to, or greater than, the response for the same analyte injected with a 10µL solvent vent injection on the 7000B. The significant increase in sensitivity of the Agilent 7010 Triple Quadrupole GC/MS System gives analysts more choices in how to improve the analytical performance of their GC/MS/MS systems: Keep the amount of sample extracted the same, but inject less sample volume in to the GC/MS/MS thus decreasing the amount of matrix injected with each sample Decrease the amount of sample extracted, keeping the injection volume the same. This can result in savings related to sample prep such as solvents, SPE consumables etc. REFERENCES [1] Determination of Chemical Contaminants in Marine Shellfish using the Agilent 7000 Triple Quadrupole GC/MS System; Agilent Application note : 5990-7714EN, April, 2011. 5

Solutions for your analytical business Markets & Applications Programs www.solutions-to-win.com This information is subject to change without notice. Agilent Technologies, Inc. 2015 Printed in EU, September 01, 2015 5991-6093EN