EARTHQUAKE SIMULATION TESTS OF BRIDGE COLUMN MODELS DAMAGED DURING 1995 KOBE EARTHQUAKE

Similar documents
Response Modification of Urban Infrastructure. 7 Chapter 7 Rocking Isolation of Foundations. Kazuhiko Kawashima Tokyo Institute of Technology

Behavior and Modeling of Existing Reinforced Concrete Columns

Centrifuge Shaking Table Tests and FEM Analyses of RC Pile Foundation and Underground Structure

AXIAL COLLAPSE OF REINFORCED CONCRETE COLUMNS

Chapter 6 Seismic Design of Bridges. Kazuhiko Kawashima Tokyo Institute of Technology

Lap splice length and details of column longitudinal reinforcement at plastic hinge region

INFLUENCE OF LOADING RATIO ON QUANTIFIED VISIBLE DAMAGES OF R/C STRUCTURAL MEMBERS

Seismic Pushover Analysis Using AASHTO Guide Specifications for LRFD Seismic Bridge Design

Sabah Shawkat Cabinet of Structural Engineering Walls carrying vertical loads should be designed as columns. Basically walls are designed in

Title. Author(s)DONG, Q.; OKAZAKI, T.; MIDORIKAWA, M.; RYAN, K.; SAT. Issue Date Doc URL. Type. Note. File Information BEARINGS

EFFECT OF SHEAR REINFORCEMENT ON FAILURE MODE OF RC BRIDGE PIERS SUBJECTED TO STRONG EARTHQUAKE MOTIONS

New model for Shear Failure of R/C Beam-Column Joints. Hitoshi Shiohara

Design of a Multi-Storied RC Building

SHAKING TABLE TEST AND ANALYSIS OF REINFORCED CONCRETE WALLS

Field Investigation and Dynamic Analysis of Damaged Structure on Pile Foundation during the 2011 off the Pacific Coast of Tohoku Earthquake

POST-PEAK BEHAVIOR OF FRP-JACKETED REINFORCED CONCRETE COLUMNS

SEISMIC PERFORMANCE OF LARGE RC CIRCULAR HOLLOW COLUMNS

AN UNLOADING AND RELOADING STRESS-STRAIN MODEL FOR CONCRETE CONFINED BY TIE REINFORCEMENTS

Title. Author(s)T. MIZUTANI; Y. NARAZAKI; Y. FUJINO. Issue Date Doc URL. Type. Note. File Information

Dynamic Stability and Design of Cantilever Bridge Columns

ε t increases from the compressioncontrolled Figure 9.15: Adjusted interaction diagram

Design of AAC wall panel according to EN 12602

Vertical acceleration and torsional effects on the dynamic stability and design of C-bent columns

CHAPTER 6: ULTIMATE LIMIT STATE

DEFORMATION CAPACITY OF OLDER RC SHEAR WALLS: EXPERIMENTAL ASSESSMENT AND COMPARISON WITH EUROCODE 8 - PART 3 PROVISIONS

Dynamic analysis of a reinforced concrete shear wall with strain rate effect. Synopsis. Introduction

EXPERIMENTS ON SHEAR-FLEXURAL BEHAVIORS OF MODEL CAST IN PLACE CONCRETE PILES

SHEAR CAPACITY OF REINFORCED CONCRETE COLUMNS RETROFITTED WITH VERY FLEXIBLE FIBER REINFORCED POLYMER WITH VERY LOW YOUNG S MODULUS

SHAKING TABLE TEST FOR FRICTIONAL ISOLATED BRIDGES AND TRIBOLOGICAL NUMERICAL MODEL OF FRICTIONAL ISOLATOR

Seismic Resistance Capacity of High-Rise Buildings subjected to Long-Period Ground Motions - E-Defense Shaking Table Test

On The Ultimate Strength of RC Shear Wall under Multi-Axes Seismic Loading Condition

Simulation of Nonlinear Behavior of Wall-Frame Structure during Earthquakes

Chapter 4. Test results and discussion. 4.1 Introduction to Experimental Results

EUROCODE EN SEISMIC DESIGN OF BRIDGES

Chapter 8. Shear and Diagonal Tension

CE5510 Advanced Structural Concrete Design - Design & Detailing of Openings in RC Flexural Members-

1. ARRANGEMENT. a. Frame A1-P3. L 1 = 20 m H = 5.23 m L 2 = 20 m H 1 = 8.29 m L 3 = 20 m H 2 = 8.29 m H 3 = 8.39 m. b. Frame P3-P6

Flexure: Behavior and Nominal Strength of Beam Sections

A Modified Response Spectrum Analysis Procedure (MRSA) to Determine the Nonlinear Seismic Demands of Tall Buildings

NUMERICAL EVALUATION FOR THE KEY DESIGN PARAMETERS THAT CAN CONTROL THE SEISMIC PERFORMANCE OF HIGHWAY BRIDGE PIER-SHALLOW FOUNDATION SYSTEMS

GEOSYNTHETICS ENGINEERING: IN THEORY AND PRACTICE

PLATE GIRDERS II. Load. Web plate Welds A Longitudinal elevation. Fig. 1 A typical Plate Girder

Earthquake Simulation Tests on a 1:5 Scale 10 - Story RC Residential Building Model

Special edition paper

A STUDY ON DAMAGE TO STEEL PIPE PILE FOUNDATION ON RECLAIMED LAND DURING HYOGO-KEN-NANBU EARTHQUAKE

ANALYSIS: THEORY AND APPLICATION FOR

HYSTERETIC PERFORMANCE OF SHEAR PANEL DAMPERS OF ULTRA LOW- YIELD-STRENGTH STEEL FOR SEISMIC RESPONSE CONTROL OF BUILDINGS

ANALYSIS OF REINFORCED CONCRETE KNEE JOINTS BASED ON QUADRUPLE FLEXURAL RESITANCE. Hitoshi Shiohara 1 and Yong Woo Shin 2.

An Evaluation of the Force Reduction Factor in the Force-Based Seismic Design

TESTS ON REINFORCED CONCRETE LOW-RISE SHEAR WALLS UNDER STATIC CYCLIC LOADING

PERFORMANCE BASED DESIGN OF SEISMICALLY ISOLATED BUILDINGS IN JAPAN

Civil Engineering Design (1) Design of Reinforced Concrete Columns 2006/7

FLEXURAL ANALYSIS AND DESIGN METHODS FOR SRC BEAM SECTIONS WITH COMPLETE COMPOSITE ACTION

Multi-level seismic damage analysis of RC framed structures. *Jianguang Yue 1)

EQUIVALENT FRACTURE ENERGY CONCEPT FOR DYNAMIC RESPONSE ANALYSIS OF PROTOTYPE RC GIRDERS

EDEM DISCRETIZATION (Phase II) Normal Direction Structure Idealization Tangential Direction Pore spring Contact spring SPRING TYPES Inner edge Inner d

SAFETY EVALUATION OF SEISMICALLY ISOLATED HOUSES WITH DISPLACEMENT RESTRAINT DEVICES UNDER SEVERE EARTHQUAKE MOTIONS

This Technical Note describes how the program checks column capacity or designs reinforced concrete columns when the ACI code is selected.

A PROPOSAL OF DESIGN PROCEDURE FOR FLEXURAL STRENGTHENING RC BEAMS WITH FRP SHEET

A q u a b l u e a t t h e G o l d e n M i l e

VTU EDUSAT PROGRAMME Lecture Notes on Design of Columns

A METHOD OF LOAD INCREMENTS FOR THE DETERMINATION OF SECOND-ORDER LIMIT LOAD AND COLLAPSE SAFETY OF REINFORCED CONCRETE FRAMED STRUCTURES

Mesh-sensitivity analysis of seismic damage index for reinforced concrete columns

Chord rotation demand for Effective Catenary Action under Monotonic. Loadings

Eurocode 8 Part 3: Assessment and retrofitting of buildings

Collapse modes of structures under strong motions of earthquake

Seismic Response Analysis of Structure Supported by Piles Subjected to Very Large Earthquake Based on 3D-FEM

twenty one concrete construction: shear & deflection ARCHITECTURAL STRUCTURES: FORM, BEHAVIOR, AND DESIGN DR. ANNE NICHOLS SUMMER 2014 lecture

THE SIMPLIFIED ELASTO-PLASTIC ANALYSIS MODEL OF REINFORCED CONCRETE FRAMED SHEAR WALLS

Appendix G Analytical Studies of Columns

THE EFFECTS OF LONG-DURATION EARTHQUAKES ON CONCRETE BRIDGES WITH POORLY CONFINED COLUMNS THERON JAMES THOMPSON

Roadway Grade = m, amsl HWM = Roadway grade dictates elevation of superstructure and not minimum free board requirement.

SEISMIC PERFORMANCE OF CONCRETE COLUMNS WITH INADEQUATE TRANSVERSE REINFORCEMENT. Alistair Boys 1 Des K. Bull 2 Stefano Pampanin 3 ABSTRACT

Shake Table Tests of Reinforced Concrete Bridge Columns Under Long Duration Ground Motions

Experimental investigation on monotonic performance of steel curved knee braces for weld-free beam-to-column connections

Experimental Study on Damage Morphology and Critical State of Three-Hinge Precast Arch Culvert through Shaking Table Tests

Seismic Assessment of a RC Building according to FEMA 356 and Eurocode 8

Author(s) Sawamura, Yasuo; Kishida, Kiyoshi;

DYNAMIC RESPONSE AND FAILURE MECHANISMS OF A PILE FOUNDATION DURING SOIL LIQUEFACTION BY SHAKING TABLE TEST WITH A LARGE- SCALE LAMINAR SHEAR BOX

Moment redistribution of continuous composite I-girders with high strength steel

The subject of this paper is the development of a design

COEFFICIENT OF DYNAMIC HORIZONTAL SUBGRADE REACTION OF PILE FOUNDATIONS ON PROBLEMATIC GROUND IN HOKKAIDO Hirofumi Fukushima 1

Lecture-08 Gravity Load Analysis of RC Structures

AMPLIFICATION OF GROUND STRAIN IN IRREGULAR SURFACE LAYERS DURING STRONG GROUND MOTION

INFLUENCE OF FLANGE STIFFNESS ON DUCTILITY BEHAVIOUR OF PLATE GIRDER

Response characteristics of R/C buildings considering impulsive force of tsunami drifting objects

SeismoBuild Verification Report (KANEPE) For version 2018

Impact-resistant behavior of shear-failure-type RC beams under falling-weight impact loading

PILE FOUNDATION RESPONSE DUE TO SOIL LATERAL SPREADING DURING HYOGO-KEN NANBU EARTHQUAKE

APPLICATION OF RESPONSE SPECTRUM METHOD TO PASSIVELY DAMPED DOME STRUCTURE WITH HIGH DAMPING AND HIGH FREQUENCY MODES

Earthquake-resistant design of indeterminate reinforced-concrete slender column elements

TRI-AXIAL SHAKE TABLE TEST ON THE THINNED WALL PIPING MODEL AND DAMAGE DETECTION BEFORE FAILURE

RELATIONSHIP OF SEISMIC RESPONSES AND STRENGTH INDEXES OF GROUND MOTIONS FOR NPP STRUCTURES

Cone-shaped socket connections for cylindrical members

THREE-DIMENSIONAL NONLINEAR DEGRADING MODEL FOR EARTHQUAKE RESPONSE ANALYSES OF CONCRETE BRIDGES

Advanced stability analysis and design of a new Danube archbridge. DUNAI, László JOÓ, Attila László VIGH, László Gergely

CONSULTING Engineering Calculation Sheet. Job Title Member Design - Reinforced Concrete Column BS8110

SHAKING TABLE TEST OF STEEL FRAME STRUCTURES SUBJECTED TO NEAR-FAULT GROUND MOTIONS

Appendix K Design Examples

USER BULLETIN 3: DETERMINATION OF UNSUPPORTED LENGTH RATIO L/Db

Transcription:

EARTHQUAKE SIMULATION TESTS OF BRIDGE COLUMN MODELS DAMAGED DURING 1995 KOBE EARTHQUAKE J. Sakai 1, S. Unjoh 2 and H. Ukon 3 1 Senior Researcher, Center for Advanced Engineering Structural Assessment and Research, Public Works Research Institute, Tsukuba. Japan, sakai55@pwri.go.jp 2 Chief Researcher, Center for Advanced Engineering Structural Assessment and Research, Public Works Research Institute, Tsukuba. Japan, unjoh@pwri.go.jp 3 Research Fellow, Hyogo Earthquake Engineering Research Center, National Research Institute for Earth Science and Disaster Prevention, Miki, Japan. ukon@bosai.go.jp ABSTRACT : A series of shake table tests of two reinforced concrete bridge column models was conducted. One model is designed to be failed in flexural at the bottom of the column (flexural failure model), and the other is designed to be failed in shear at the cut-off point of the longitudinal reinforcement (shear failure model); both are models of bridge columns that were severely damaged during the 1995 Hyogo-ken Nanbu (Kobe), Japan, earthquake. The models are one-third scaled ones of full-scaled reinforced concrete bridge column models that are planed to be tested on the E-Defense in 27 and 28. Failure mechanisms under strong ground excitation and three dimensional dynamic behaviors of these columns were investigated. The flexural failure column was failed around the bottom of the column. Spalling of cover concrete, buckling of longitudinal reinforcement, and crush of core concrete were observed after the test. The shear failure column was eventually failed in shear. The flexural cracks were first observed around the cut-off point of the longitudinal reinforcement, and then shear diagonal cracks developed, resulting in destructive shear failure. Both final failure modes are typical ones observed during the 1995 Kobe earthquake. KEYWORDS: bridge, reinforced concrete column, shake table test, flexural failure, shear failure 1. INTRODUCTION The 1995 Hyogo-ken Nanbu, Japan, earthquake (Kobe earthquake) caused destructive damage to bridges. A research program on bridge structures using the world largest shake table, E-Defense, has been conducted since 25 (Kawashima et al. 28), which includes a series of shake table tests of full-scaled reinforced concrete bridge columns. The program are expected to provide valuable information on the failure mechanisms of reinforced concrete bridge columns that were severely damaged during the 1995 Kobe earthquake as well as on the effect of specimen size on the evaluation of the seismic performance and dynamic failure mechanisms, and on the development of advanced analytical models. As a preliminary study of the full-scaled shake table tests of reinforced bridge columns, a series of shake table tests of two small-scaled reinforced concrete bridge column models was conducted (1) to provide experimental data of small-scaled models to investigate the effect of specimen size, and (2) to conduct preliminary research on the dynamic failure mechanism of reinforced concrete bridge columns that were damaged during the 1995 Kobe earthquake. 2. TEST SETUP AND SPECIMENS 2.1. Overview of Shake Table Test of Full-Scaled Reinforced Concrete Bridge Columns Seven specimens are planed to be shaken on the E-Defense in the research program for bridge structures (Kawashima et al. 27). Among those, two specimens are the models that were severely damaged during the 1995 Kobe earthquake, and these two are the specimens that this project focuses on. One is designed to be

failed in flexural at the bottom of the column (flexural failure model) and the test has been conducted in 27 (Kawashima et al. 28), and the other is designed to be failed in shear at the cut-off point of the longitudinal reinforcement (shear failure model), which is to be tested in 28. Figure 1 shows the test setup, reinforcement details of the specimens and bearing conditions. Two girders, which steel blocks as weights of a superstructure are fixed to, are supported by fixed bearings on the top of the specimen and a longitudinal-movable/ transverse-fixed bearing at each end. Two sliding bearing are placed on each side of the fixed bearing on the specimen to prevent overturning of the decks. Due to this setup, the inertia force of the girder-block assembly is applied to the top of the specimen (7.5 m from the bottom of the column) in the longitudinal direction, and to the center of the gravity of the girder-block assembly (9.14 m from the bottom) in the transverse direction. The inertia mass of each girder-block assembly excluding mass of the load cells and bearings on the specimen is 145 ton. Since all the inertia force is applied to the specimen due to the boundary condition, the inertia mass in the longitudinal direction is 289 ton. In the transverse direction, on the other hand, not only the specimen but also the end supports carry the inertia force. Thus, the inertia mass in the transverse direction is 199 ton. The diameter of the column is 1.8 m, and the height of the column is 7.5 m. 8 of SD345, 29-mm-diameter deformed bars are arranged in the flexural failure model as the longitudinal reinforcement without cut-off. On the other hand, two cut-off points are designed for the shear failure model. The inner rebar is anchored at 1.95 m from the bottom of the column, and the middle rebar is anchored at 3.95 m. At the bottom, 8 of SD345, 32-mm-diameter deformed bar are arranged. As transverse reinforcement, SD345, 13-mm-diameter deformed bars are provided for both the columns. The pitch of the transverse hoops is set at 3 mm excluding the both ends of the column. In the region of about 1 m from the bottom and the top of the column, the outer transverse reinforcement is arranged at 15-mm-pitch. The transverse reinforcement is anchored with lap splices, and the anchorage length is 3 mm. (a) Test setup (b) Flexural failure model (c) Shear failure model End-Support Column End-Support : Sliding Bearings : Fixed for TR; Free for LG and Rotation : Fixed for LG & TR; Free for Rotation (d) Boundary conditions of girder-block assembly Figure 1 Test setup and specimens of full-scaled bridge column models

The design concrete strength is set to be 27 N/mm 2. The design yield strength of SD345 bars is 345 N/mm 2. 2.2. Test Setup and Specimens for 1/3-Scaled Models Figure 2 shows the test setup and specimens of one-third scaled models. The specimens are designed considering the similitude requirements (Krawinkler and Moncarz, 1982). Because the plan, specimen details, setup, etc, of the full-scaled models had been minor changed since the test plan of the small-scaled test had been decided, however, some conditions such as the design material strength, the transverse reinforcement ratio, etc, do not satisfy the similitude requirements. A similar setup and the same bearing conditions with the full-scaled model test were used. In this test program, the longitudinal and transverse directions are defined as the Y and X directions, and the sides face the X positive and the X negative directions are defined as the Xp and Xn faces, respectively. Likewise, the Yp and Yn faces are defined. Due to the setup, the points inertia force applied to are 2.5 m and 3.65 m from the bottom of the column for the longitudinal (Y) and transverse (X) directions, respectively. Inertia mass in the longitudinal and transverse directions are 37.8 ton and 26.6 ton, respectively. Z (UD) (a) Test setup (b) Flexural failure specimen (c) Shear failure specimen (d) Test setup and dimensions Figure 2 Test setup and specimens of 1/3-scaled bridge column models Figure 3 shows the cross sections. The diameter of the column is.6 m, and the height of the column is 2.5 m. 8 of SD295A, 1-mm-diameter deformed bars are arranged for the flexural failure specimen as the longitudinal reinforcement without cut-off. The longitudinal reinforcement ratio is 2.2%. On the other hand, two cut-off points are designed for the shear failure specimen. The inner rebar is anchored at.63 m from the bottom of the column, and the middle rebar is anchored at 1.3 m. At the bottom, 1 of SD345, 1-mm-diameter deformed bar are provided. The longitudinal reinforcement ratios at the bottom, lower cut-off

point, and the upper cut-off point are 2.52%, 2.2% and 1.1%, respectively. As transverse reinforcement, SD295, 3-mm-diameter deformed bars are provided for both the specimens. The pitch of the transverse hoops is set at 1 mm excluding the both ends of the column. In the region of about.3 m from the bottom and the top of the column, the outer transverse reinforcement is arranged at 5-mm-pitch. The transverse reinforcement ratio at the bottom of the column is.1%. The transverse reinforcement is anchored with lap splices, and the anchorage length is 1 mm. The design concrete strength is 27 N/mm 2. Table 1 shows the material properties, which were obtained from the material tests. (a) Upper cut-off point (b) Lower cut-off point (c) bottom (1) Flexural failure specimen (2) Shear failure specimen Figure 3 Cross sections of 1/3-scaled bridge column models Table 1 Material Properties (a) Concrete (b) Reinforcing steel f c (N/mm 2 ) E c (kn/mm 2 ) f sy (N/mm 2 ) E s (kn/mm 2 ) Flexural Failure Specimen 27.9 28.8 Longitudinal bars (SD295A) 351.4 178.3 Shear Failure Specimen 28.8 26.5 Longitudinal bars (SD345) 374.2 179.8 Hoops 28.4 212.9 The ductility performance, flexural strength and shear strength were evaluated based on the JRA specifications (JRA, 22) using the actual material properties. The crack, yield and ultimate displacements at the top of the column of the flexural failure specimen are.7 mm, 1 mm, and 28 mm in the longitudinal direction. The flexural strengths in the longitudinal and transverse directions are 188 kn and 129 kn, respectively. Figure 4 compares the flexural strength and shear strength along the column height of the shear failure specimen. Flexural strength at each section was computed based on the moment-curvature analysis with consideration of cut-off of the longitudinal reinforcement. The anchorage length of the longitudinal bars is assumed to be about.21 m according to the JSCE standard specification (JSCE 22). The shear strength P s was computed based on the following equation according to the JRA specifications: where Sc = cccec ptτcbd ; P s = Sc + Ss (2.1) ( sinθ cosθ ) Awσ syd + Ss = (2.2); (2.3) 1.15a where S c is the concrete shear capacity, S s is the shear strength provided by reinforcing steel, τ c is the averaged shear stress, coefficients, c c, c e, cpt are the modification factors on the effects of cyclic loading, the effective height and the axial tensile reinforcement ratio, respectively, b is the width of cross section, d is the effective height, A w is the sectional area of hoop ties, σ sy is the yield strength of hoop ties, θ is the

angle between hoop ties and the vertical axis, and a is the spacing of hoop ties. P s is the shear strength without consideration of shear strength deterioration due to the cyclic loading effect. To evaluate the actual shear strengths of the specimen, τ c was determined from the following equation (Kawano et al. 1996), which was proposed as mean value of experimental data. 1 1 3 3.33 24 1. 2 c =.72 d fc ρl τ (2.4) where d is the effective depth (m), f c is the concrete strength (N/mm 2 ), and ρ l is the longitudinal reinforcement ratio (%). τ c is determined to be.731 N/mm 2 for the critical section, where is the region of 1.2 m to 1.6 m from the bottom. In Figure 4, the shear strength of the specimen obtained based on the averaged shear stress (=.366 N/mm 2 ; c e c pt τ c =.446 N/mm2 ) according to the JRA specification is also shown. The averaged shear stress is determined as the values that is equal to the mean minus twice of the standard deviation of Eq. (2.4) because of safety consideration for the design. To predict the actual failure mode of the shear failure column, the shear strength of the column based on Eq. (2.4) was considered. According to Figure 4, flexural yielding first occurs at the bottom and the upper cut-off point because the flexural first-yield strengths are the smallest. The smallest shear strength along the column is 21 kn as P s and 172 kn as P s in the region of 1.2 m to 1.6 m from the bottom. This P s is 35% larger than the flexural first-yield strength at the bottom and the upper cut-off point and 3% larger than the flexural ultimate strength of these points. If the deterioration of the shear strength due to cyclic flexural damage is considered, the shear strength decreases and becomes smaller than the flexural ultimate strength. Thus, the shear failure specimen was expected to be damaged in flexure around the upper cut-off point, and then shear failure to occur around the upper cut-off point. 1.8.43 1.3.633.317.3.6.4.383 Height (m) 2 1.5 1.5 2 4 Force (kn) 2 4 Force (kn) Flexural Capacity First-yield Strength Ultimate Strength Shear Capacity JRA EQ(2.4) (a) Reinforcement details (b) Strength in LG direction (c) Strength in TR direction Figure 4 Evaluated failure mode of shear failure column P s P s 2.3. Input Ground Motions The specimens were tested under three dimensional ground motions. Ground accelerations measured at JR Takatori station during the 1995 Kobe earthquake (Nakamura, 1995) were selected for this study and the NS, EW and UD components were inputted in the longitudinal (Y), transverse (X), and vertical (Z) directions, respectively. The tests had two phases; one is for dynamic response in elastic range, and the other is for that in nonlinear range. The amplitude of the ground motions were scaled by 1% and 8% for the tests, respectively, based on the preliminary analytical studies. The time of the ground motions was scaled using a time scale factor equal to.6 ( 3 ) considering the similitude requirements.

3. FAILURE AND RESPONSE OF FLEXURAL FAILURE SPECIMEN The fundamental natural periods prior to the test were.25 seconds and.38 seconds for the longitudinal and transverse directions, respectively. The maximum response displacements in the longitudinal and transverse directions were 2.6 mm and 1.6 mm. No flexural cracks were observed after the elastic level test. Figure 5 shows the damage progress of the specimen during the nonlinear level test, and Figure 6 shows response displacement and lateral force versus lateral displacement hystereses during the nonlinear level test. Several flexural cracks were observed up to 3 seconds around the bottom of the column, when the response displacement was about the computed ultimate displacement. The maximum response displacement occurred at 3.1 seconds, which were 123 mm and 115 mm in the longitudinal and transverse directions. As a distance from the origin, the maximum response was 168 mm, which was 6 times larger than the ultimate displacement of the specimen. Spalling of cover concrete and buckling of longitudinal reinforcing bars were observed. The lateral forces observed were smaller to the values that the current design specification predicts, indicating the bilateral flexural loading effects. Yn Yp Yn Yp Yp Yn Yp Yn 3.1 sec 3.6 sec 3.1 sec 3.6 sec (a) Xp face (b) Xn face Figure 5 Damage progress of flexural failure specimen Displacement (m).15 -.15 Lateral Force (kn) 2 : Yield : Ultimate 5 1 15 -.15.15 -.15.15 Time (sec) Lateral Displacement (m) Lateral Displacement (m) (a) Response displacement (b) Lateral force-displacement hystereses Figure 6 Response of flexural failure specimen at top of column -2 : Yield : Ultimate Xn-Yp Xp-Yn Figure 7 Failure mode of flexural failure specimen As shown in Figure 7, flexural damage occurred in the region of.2 m ~.4 m from the bottom of the column,

and longitudinal reinforcing bars in the middle and outer layers were buckled at the Xn-Yp face where was the compression region when the maximum displacement occurred at 3.1 seconds. On the other hand, damage occurred in the region of.2 m ~.45 m from the bottom at the Xp-Yn face. Reinforcing bars in all three layers were buckled. The pitch of the transverse reinforcement changes at.317 m from the bottom, resulting in the rebar buckling in the Xp-Yn face. The failure mode is similar to one of the typical failure modes observed during the 1995 Kobe earthquake. 4. FAILURE AND RESPONSE OF SHEAR FAILURE SPECIMEN The fundamental natural periods prior to the test were.27 seconds and.38 seconds for the longitudinal and transverse directions, respectively. The maximum response displacements in the longitudinal and transverse directions were 2.6 mm and 1.6 mm. Minor flexural cracks were observed after the elastic level test around the lower cut-off point. Figures 8 and 9 show damage progress, response displacement and lateral force versus lateral displacement hystereses of the shear failure specimen during the nonlinear level test. In Figure 9, the response after 3.1 seconds shows dotted lines because the top slab of the column contacted to the safety frame and thus the results included this effect after 3.1 seconds. At about 2 seconds of the nonlinear level test, flexural cracks were observed at 1.2 m from the bottom, and then slight shear cracks initiated around the same location. The lateral displacement at this point was about 4 mm. When the lateral displacement increased up to 175 mm from 2.8 to 3.1 seconds, first flexural damage occurred around 1.4 m from the bottom, which was around the upper cut-off point, and then the shear cracks extended from 1.4 m to.6 m, causing the destructive shear failure, which was one of the major causes of the destructive damage during the 1995 Kobe earthquake. 2.8 sec 2.9 sec 3. sec 3.1 sec 3.7 sec 4.4 sec Figure 8 Damage progress of shear failure specimen Displacement (m).15 -.15 Lateral Force (kn) 2 5 1 15 -.15.15 -.15.15 Time (sec) Lateral Displacement (m) Lateral Displacement (m) (a) Response displacement (b) Lateral force-displacement hystereses Figure 9 Response of shear failure specimen at top of column -2 2.87sec 2.8sec 2.93sec 2.92sec The lateral force in the longitudinal direction reached 2 kn at 2.87 seconds, and then the force decreased to 16 kn due to the shear failure. Thus, the shear capacity of the specimen was estimated to be 2 kn. Because

the P s computed using Eq (2.4) for the averaged stress of concrete was 221 kn, the shear capacity obtained from the test was about 9% of the computed shear capacity. 5. CONCLUSIONS A series of shake table tests was conducted for one-third scaled models of the full-scaled reinforced concrete bridge column models to provide experimental data of small-scaled specimens to investigate the effect of specimen size, and to conduct preliminary research on the dynamic failure mechanism and response of reinforced concrete bridge columns that were damaged during the 1995 Kobe earthquake. Below are the conclusions determined from the study: 1. The damage progress of the typical failure modes, which are the flexure failure at the bottom of the column and shear failure after flexural damage around the cut-off point of longitudinal reinforcement, were simulated on a shake table. 2. The current design specification provides a good estimation of the flexural capacity of the flexural failure specimen. Only flexural cracks were observed at the computed ultimate displacement, and spalling of cover concrete, buckling of longitudinal reinforcement were observed when the lateral displacement exceeded six times of the computed ultimate displacement. 3. The current design specification estimated about 6% of the observed shear capacity because of the safety consideration in the specification. If the averaged shear stress is obtained from Eq.(2.4), the shear capacity was approximately predicted. The failure mode was also predicted by comparison of the flexural capacity and the shear capacity; the flexural damage around the upper cut-off point triggered the shear failure. 4. Experimental data of small scaled specimens is provided to investigate the specimen size effect on the dynamic failure mechanism and nonlinear response. ACKNOWLEDGEMENTS Support for this research was provided in part by the NEES-E-Defense collaboration research projects for bridges of the National Research Institute for Earth Science and Disaster Prevention (NIED). The authors extended their appreciation to the members of the executive committee for the research program of bridge structures (Chair: Prof. Kazuhiko Kawashima) for their valuable advices. REFERENCES Japan Society of Civil Engineers (JSCE) (22). Standard specifications for concrete structures-22, Structural performance verification. JSCE, Tokyo, Japan. Japan Road Association (JRA) (22). Part V Seismic design, Design specifications of highway bridges. Maruzen, Tokyo, Japan. Kawano, H., Watanabe, H. and Kikumori, Y. (1996). Report on shear strength of large scale reinforced concrete beams. Technical memorandum of PWRI 3426. Kawashima, K. and Unjoh, S. (1997). The damage of highway bridges in the 1995 Hyogo-ken nanbu earthquake and its impact on Japanese seismic design. Journal of Earthquake Engineering 1:3, 55-542. Kawashima, K., Ukon, H. and Kajiwara, K. (27). Bridge seismic response experimental program using E-Defense. Proc. 39th Panel on Wind and Seismic Effect, UJNR, Tsukuba, Japan. Kawashima, K., Sasaki, T., Kajiwara, K. Ukon,U. Unjoh, S., Sakai, J., Kosa, K., Takahashi, Y. and Yabe, M. (28). Seismic performance of a flexural failure type RC bridge column based on E-Defense excitation. Proc. 4th Panel on Wind and Seismic Effect, UJNR, Gaithersburg, MD, USA. Krawinkler, H. and Moncarz, P. D. (1982) Similitude requirements for dynamic models. Dynamic Modeling of Concrete Structures SP 73-1, ACI, 1-22, Detroit, Michigan. Nakamura, Y. (1995). Waveform and its analysis of the 1995 Hyogo-ken Nanbu earthquake. JR Earthquake Information 23c, Railway Technical Research Institute, Japan.