LOW E SATINÉ 5500 LOW E

Similar documents
LOW E SATINÉ 5500 LOW E

SCREEN LOW E SATINÉ 5500 LOW E

SCREEN LOW E SATINÉ 5500 LOW E

Natté P CLARITY & COMFORT POLYESTER OF = 1-10% COPACO NATTÉ P

Natté COLLECTION CLARITY & COMFORT GLASSFIBRE OF = 1-10% COPACO NATTÉ

Blockout Déco N203 COLLECTION BLOCK SUNLIGHT BLOCKOUT OF = 0% COPACO BLOCKOUT DÉCO N203

Serge 600 COLLECTION REFLECTS SUNLIGHT OUTDOORS GLASSFIBRE OF = 5%

Working of a SUNLUX SUNSCREEN

visual comfort Natté 390 GLASSFIBRE OF = 3%

latest trends & designs Déco N203 ARCHITECTS SELECTION GLASSFIBRE OF = 3%

reflect sunlight outdoors Serge 600 ARCHITECTS SELECTION GLASSFIBRE OF = 5%

Technical info (001042)

Solar Radiation 230 BTU s per Hr/SF. Performance Glazing Coatings, Layers & Gases

FIBER TEXTILES BY SNOWSOUND FIBER 2R LINE-R

Winter Night. Thermos 6mm Outdoors # #

Glazing selection for solar design

HIGHLY INSULATING AEROGEL GLAZING

TREES Training for Renovated Energy Efficient Social housing

FIBER TEXTILES BY SNOWSOUND FIBER 2 LINE

BRE Client Report. Calculation of summertime solar shading performance for MicroLouvre. Prepared for: Smartlouvre. BRE Watford, Herts WD25 9XX

Philips luminous textile with. Specifications sheet luminous textile panel

Declarations of equivalence of Verosol sun screens. SilverScreen and EnviroScreen

Introducing Cyclone Enclosure Plus Insect Screening

INVESTIGATING GLAZING SYSTEM SIMULATED RESULTS WITH REAL MEASUREMENTS

The energy performance of an airflow window

ISO INTERNATIONAL STANDARD. Thermal performance of windows, doors and shutters Calculation of thermal transmittance Part 1: Simplified method

Medical Oxygen Regulators

Design strategy for Low e windows with effective insulation

Guide Specifications Section

Calculating the heat transfer coefficient of frame profiles with internal cavities

SL27C SL32C. ScreenLine. Technical Catalogue. english. double-glazed unit 27 mm 32 mm

ISO INTERNATIONAL STANDARD

Evaluation of Program Calculation Procedures according to Standards EN 673 and EN 410

THERMAL TRANSMITTANCE OF MULTI-LAYER GLAZING WITH ULTRATHIN INTERNAL PARTITIONS. Agnieszka A. Lechowska 1, Jacek A. Schnotale 1

Heat Dissipation Design

CFC, HCFC free, GWP zero thermal insulation in the form of tubes, sheets, coils and self-adhesive tape, a Flexible Elastomeric Foam product complying

Lediko INLENE luminaire INLENE. Industrial LED luminaire

EXPERIMENTAL DETERMINATION OF SPECTRAL AND ANGULAR DEPENDENT OPTICAL PROPERTIES OF INSULATING GLASSES

Technical Data Sheet - Planibel

industry hall : highbay luminaire NJ700 LED Project number : sample system Customer : Processed by : Siteco Light Consulting Date : 07/2013

Fundamentals of light

Fundamentals of light

Double-Skin Facade in Low-Latitude: Study on the Absorptance, Reflectance, and Transmittance of Direct Solar Radiation

Customer: Ashton Industrial Sales Ltd. South Road, Harlow Essex CM20 2AR UNITED KINGDOM. Project/Customer: Profilex HM spacer

Collective Road Lighting class ME 5

LP NET. 1 About LP NET. 2 Working Principle. TEL r.a. FAX

TRANSPARENT INNOVATIVE MATERIALS: ENERGETIC AND LIGHTING PERFORMANCES EVALUATION

Description of Benchmark Cases for Window and Shading Performance Calculation

AR/IA 241 LN 231 Lecture 4: Fundamental of Energy

25 (μh/ω) for sizes 0,5 / 0,75 / 1 mm2 Maximum L/R Ratio:

Available online at ScienceDirect. Energy Procedia 54 (2014 )

1 /square Intermittent temperature range -250 C to 150 C (-420 F to 300 F) Continuous temperature range -250 C to 120 C (-420 F to 250 F)

File N N Document DE/2 - Page 1/6

CFC, HCFC free, GWP zero thermal insulation in the form of tubes, sheets, coils and self-adhesive tape, a Flexible Elastomeric Foam product complying

WITH LOW EMISSIVITY GLASS

ABB SpA COMEM Operating Unit Strada Regionale 11, Signolo Montebello Vicentino (VI) - ITALY

QIRT th International Conference on Quantitative InfraRed Thermography

CFC, HCFC free, GWP zero thermal insulation in the form of tubes, sheets, coils and self-adhesive tape, a Flexible Elastomeric Foam product complying

METHOD OF IN-SITU MEASUREMENT OF THERMAL INSULATION PERFORMANCE OF BUILDING ELEMENTS USING INFRARED CAMERA

It s all about performance. Ultra Performance

TIR100-2 Measurement of Thermal Emissivity

Eye Safety With LED Components

Control Standard for Handling Chemical Substances in Products, Parts and Materials

Z-POWER LED Series. Technical Datasheet for F50380 SEOUL SEMICONDUCTOR

The official directions are written in Chinese, this English edition is for your reference only -1-

THERMODYNAMICS METHODS OF HEAT TRANSFER RADIATION

Field IT 50T Series Transmitters

LP PYRA Installation and Mounting of the Pyranometer for the Measurement of Global Radiation:

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

Accurate Measurement of Transmittance and Reflectance for Engineering Applications

SWARCO LIMBURGER LACKFABRIK GmbH Road Marking Systems. 1-component Afterglow paint system TECHNICAL INFORMATION

ASSESSMENT OF NON-COHERENT LIGHT SOURCES

Solar shading for low energy buildings

Daylighting Buildings Nexus November 12, 2009

LedEngin, Inc. High Luminous Efficacy White Power LedFlex Emitter LZ4-00CW15. Key Features. Typical Applications. Description

SignalSure 150. Mid power solution AUTOMOTIVE. SignalSure 150 is a compact, surface-mount, mid power LED signaling

OPERATING MANUAL. EIB-Kombisensor AS 315 N

ABB temperature measurement Radiation thermometry. Measurement made easy. Process temperature measurement practice--non-contacting

Mineral Render & Silicone Paint Colour Chart

Increased thermal induced climatic load in insulated glass units

TEST REPORT IEC and/or EN Photobiological safety of lamps and lamp systems

SENSITIVITY OF THE SOLAR HEAT GAIN COEFFICIENT OF COMPLEX FENESTRATION SYSTEMS TO THE INDOOR CONVECTION COEFFICIENT

Window air permeability measurement, watertightness and resistance to wind load (designation of the test)

How to evaluate daylight. Initiated by the VELUX Group

The Perfect Symmetry of Form and Function

DEVELOPMENT OF THE MEASURING SYSTEM FOR ANALYSING THE THERMAL PROPERTIES OF CLOTHING

KELLY COLOR THERM SYSTEM Tinting System based on COOL technology

LED light engines LED compact. Module SLE G7 ADV Modules SLE ADVANCED

ASSOCIATION POUR LA CERTIFICATION DES MATERIAUX ISOLANTS

Test Results: Results of the test period on 06/19/16 using the Equivalent CTS Method: Thermal transmittance at test conditions (U s ):

L u m b e r M e l a m i n e H a r d w o o d P l y w o o d A r c h i t e c t u r a l P a n e l s C o l o r e d C a u l k P a r t i c l e B o a r d E

NYY-J/-o 34 NYCWY 36 NYCY 37 NAYY 38

Rosalite 9148 UV D 9148

Transvision: a Light Transmission Measurement System for Greenhouse Covering Materials

GRAPHENE FLAGSHIP TECHNOLOGIES

TEST REPORT IEC and/or EN Photobiological safety of lamps and lamp systems

Grau 1214 D Values marked with do not apply to the type of glass or no values are available.

CHEMICAL-RESISTANT BOOTS COMFORT & SAFETY SOLUTIONS PROTECTION AND COMFORT YOU DESERVE

Lamp measurement report - 3 Oct V led strip 2500K 10.5W.m-1 by TopLEDshop

Effect of Installing a Curved Venetian Blind to the Glass Window on Heat Transmission

Transcription:

SCREEN LOW E INTELLIGENT FABRICS FOR SOLAR PROTECTION COLLECTION 2015 2018 Width: 240 cm www.sunscreen-mermet.com

LOW E THERMAL SHIELD FOR INTERNAL BLINDS 78% OF SOLAR REFLECTANCE 15% EMISSIVITY for thermal comfort all year round Thanks to its double-sided metallization, the Satiné 5500 Low E fabric offers: EXCELLENT HEAT PROTECTION. The fabric alone reflects 78% OF SOLAR ENERGY (Rs = 0,78) and offers a gtot of 0,13 with a benchmark of type D glazing (g = 0,32, U = 1,1) VERY LOW EMISSIVITY. The unequalled emissivity level of 15% minimizes transmission of heat or cold from the glazing. The fabric acts as an INSULATOR FOR THE GLAZING, increasing INTERIOR COMFORT in both the SUMMER AND WINTER EXCELLENT VISUAL COMFORT thanks to total glare control, a clear view to the outside and optimization of incoming natural light (Tv = 4%) A BUILDING SKIN that contributes to the REDUCTION OF ENERGY CONSUMPTION for air conditioning, lighting and heating Contributes to LEED and BREEAM certification EXCELLENT DURABILITY: Mechanical strength test of 10.000 cycles (class 3 NF EN 13120) TECHNICAL DATA Composition Fire, smoke classification and other official test reports* 42% Fibreglass - 58% PVC M1 (F) - NFP 92 503 B1 (DE) - DIN 4102-1 Euroclass C-s3-d0 (EU) - EN 13501-1 mounted according to EN 13823 & EN 14716 FR (US) - NFPA 701 HHV: 13,5 MJ/kg (7,02 MJ/m²) Health, safety Greenguard : Guarantee of indoor air quality (VOC) Antibacterial: More than 99% of bacteria destroyed - ASTM E 2180 Openness factor 3% UV screen 96% Emissivity 0,15 Width 240 cm Weight/m² 520 g ± 5% - ISO 2286-2 Thickness 0,65 mm ± 5% - ISO 2286-3 Mechanical resistance Breaking Tear Folding Warp > 220 dan/5 cm 10 dan 100 dan/5 cm Weft > 185 dan/5 cm 7 dan 100 dan/5 cm ISO 1421 EN 1875-3 ISO 1421** Elongation (warp and weft) < 10% - ISO 1421 Packaging Rolls of 33 lm Making up Advice note on request This product's technical data are in conformity with this brochure as of the date of publication. MERMET SAS reserves the right to change the technical data; only those provided on the company's website www.sunscreen-mermet.com shall be deemed to be authentic. Where applicable, MERMET SAS also reserves the right to withdraw this product from sale should any of the technical properties or characteristics set out above prove to be inadequate or rendered impossible as a result of a change in regulations or in knowledge or understanding. * Reports available on request, please contact Mermet ** Internal procedure derived from ISO 1421 standard

LOW E FIRE RETARDANT FIVE YEAR WARRANTY LOW EMISSIVITY REACH COMPLIANT ANTIBACTERIAL 10000 10000 CYCLES Colours may be slightly different from the actual ones

THERMAL AND OPTICAL FACTORS in the European standard EN 14501 - OF 3% Fabric Colour Ts Rs As Thermal factors Fabric + Glazing gtot internal blind C : gv = 0,59 D : gv = 0,32 Tv Optical factors Visual comfort classification (EN 14501 standard) Daylight utilisation Glare control Night privacy Outward visibility Satiné 5500 Low E 4 78 18 0,26 0,13 4 1 3 2 2 gv = 0,59: Solar factor of standard glazing (C), low-emission 4/16/4 double glazing filled with Argon (U value thermal transmittance = 1,2 W/m²K). gv = 0,32: Solar factor of standard glazing (D), reflecting low-emission 4/16/4 double glazing filled with Argon (U value thermal transmittance = 1,1 W/m²K). Samples tested according to EN 14500 standard defining the measurements and calculation methods as specified in the standard EN 13363-2 Solar protection devices combined with glazing calculation of solar and light transmittance - part 2: EN 13363-2 detailed method" and EN 410 Glass in building - Determination of luminous and solar characteristics of glazing. Comfort classification according to EN 14501 standard: very little effect little effect moderate effect good effect very good effect Available on request: - Spectral values - Calculation of solar factor gtot of our fabrics with the glazings of the project COMPARISON OF THERMAL AND OPTICAL PERFORMANCES Measurement of heat point by thermal camera after 3 minutes of exposure Fabrics tested Satiné 5500 Low E 5500 Métal - 0707 Pearl Coated polyester fabric - Pearl Competitor s low-emissivity fabric Rs ελ gtot internal blind Tv C : gv = 0,59 D : gv = 0,32 78 41 44 65 0,15 0,80 0,90 0,35 0,26 0,41 0,42 0,36 0,13 0,22 0,27 0,25 4 8 5 4 Rs : Solar reflectance ελ : Emissivity Tv : Visible light transmittance

COMPARISON OF GTOT VALUES for benchmark glazing EN 14501 gtot internal blind 0,45 0,40 0,35 0,30 0,25 0,20 5500 Low E 5500 Métal Coated polyester fabric Competitor's low-emissivity fabric 0,15 0,10 gv = 0,59 gv = 0,32 glazing EMISSIVITY IN FOCUS The emissivity of a material is its ability to re-emit the energy received through conduction (heat/cold). A fabric with a low level of emissivity will limit the effect of inward radiation by limiting how cold it feels in winter and how hot it feels in summer. The energy emitted through this reflection is kept inside so reducing air conditioning and heating consumption which in turn helps reduce energy consumption. Summer comfort Winter comfort

www.sunscreen-mermet.com V5-03/2017 - : Kortilux - espai@espai-foto.com - P. Paugois - Window Treatment NZ - Rieldecor - Palacio de justicia de Zaragoza - Sergio Sebastian - Mermet SAS 58, chemin du Mont Maurin - FR-38630 Les Avenières Veyrins-Thuellin Tel. +33(0) 474 336 615 - Fax +33(0) 474 339 729 This brochure must be read and interpreted in accordance with the General Terms & Conditions of Sale of MERMET SAS, with which it forms an indissoluble whole. The General Terms & Conditions of Sale that are current at any time are those contained on the MERMET SAS website at the following address: www.sunscreen-mermet.com.