Radiation Protection Dosimetry (2007), Vol. 126, No. 1 4, pp Advance Access publication 23 May 2007

Similar documents
Characterization of heavy charged particle fields using fluorescent nuclear track detectors

An extremity (wrist) dosemeter based on the Landauer InLight TM whole body dosemeter

Development And Testing of a Thermoluminescent Dosemeter for Mixed Neutron-Photon-Beta Radiation Fields

Energy Response Characteristics of Several Neutron Measuring Devices Determined By Using the Scattered Neutron Calibration Fields of KAERI

Calculation of Bubble Detector Response Using Data from the Matroshka-R Study

Energy response for high-energy neutrons of multi-functional electronic personal dosemeter

The scanning microbeam PIXE analysis facility at NIRS

Neutron and/or photon response of a TLD-albedo personal dosemeter on an ISO slab phantom

Recent Activities on Neutron Calibration Fields at FRS of JAERI

Personal Dose Monitoring System

THE ACTIVE PERSONNEL DOSIMETER - APFEL ENTERPRISES SUPERHEATED DROP DETECTOR*

Fast-Neutron Production via Break-Up of Deuterons and Fast-Neutron Dosimetry

Radiation Protection Dosimetry (2006), Vol. 118, No. 3, pp Advance Access publication 6 October 2005

Single track coincidence measurements of fluorescent and plastic nuclear track detectors in therapeutic carbon beams

Jeancarlo Torres, CHP. Naval Surface Warfare Center Carderock Division

THE mono-energetic hadron beam such as heavy-ions or

Neutron Metrology Activities at CIAE (2009~2010)

Chapter V: Cavity theories

Chapter VIII: Photographic films

Introduction into Positron Annihilation

Neutron Dosimetry with Ion Chamber-Based DIS System

Validity of the Analysis of Radiochromic Film Using Matlab Code

A quantitative kinetic model for Al 2 O 3 :C: TL response to UV-illumination

Performance Test of the Electronic Personal Neutron Dosemeter in Neutron Fields Simulating Workplaces of MOX Fuel Fabrication Facilities

COMPUTER SIMULATION OF THE PROCESSES IN A PAIR OF CR-39 TRACK DETECTORS DURING NEUTRON EXPOSURE

Neutron dosimetry and microdosimetry with track etch based LET spectrometer

A quantitative kinetic model foral 2 O 3 :C: TL response to ionizing radiation

A Monte Carlo Simulation for Estimating of the Flux in a Novel Neutron Activation System using 252 Cf Source

ERINDA PAC 1/4 Testing the UAB Extended Range Bonner Sphere Spectrometer for high energy neutrons UU-TSL, Uppsala, Sweden UAB Barcelona

Radiation Protection Dosimetry Advance Access published December 21, 2006

ABSORBED DOSE IN ION BEAMS: COMPARISON OF IONISATION- AND FLUENCE-BASED MEASUREMENTS

DOSIMETRY ON THE FOTON M2/BIOPAN-5 SATELLITE

A new neutron monitor for pulsed fields at high-energy accelerators

Chapter 11: Neutrons detectors

Bonner Sphere Spectrometer. Cruzate, J.A.; Carelli, J.L. and Gregori, B.N.

EEE4106Z Radiation Interactions & Detection

Multilayer Nuclear Track Detectors for Retrospective Radon Dosimetry

Introduction to Radiological Sciences Neutron Detectors. Theory of operation. Types of detectors Source calibration Survey for Dose

Light ion recoil detector

A Measuring System with Recombination Chamber for Photoneutron Dosimetry at Medical Linear Accelerators

PECULIARITIES OF FORMING THE RADIATION SITUATION AT AN AREA OF NSC KIPT ACCELERATORS LOCATION

Geant4 simulation of SOI microdosimetry for radiation protection in space and aviation environments

Introduction. Neutron Effects NSEU. Neutron Testing Basics User Requirements Conclusions

A COMPUTER PROGRAM FOR THE DECONVOLUTION OF THERMOLUMINESCENCE GLOW CURVES K. S. Chung 1,, H. S. Choe 1, J. I. Lee 2, J. L. Kim 2 and S. Y.

Digital imaging of charged particle track structures with a low-pressure optical time projection chamber

International Journal of Scientific & Engineering Research, Volume 5, Issue 3, March-2014 ISSN

Update on Calibration Studies of the Canadian High-Energy Neutron Spectrometry System (CHENSS)

Monte Carlo Simulation concerning Particle Therapy

Radiation Protection Dosimetry (2007), Vol. 126, No. 1 4, pp Advance Access publication 11 May 2007

POSTER EVIDENCE FOR FAST NEUTRON EMISSION DURING SRI S SPAWAR/GALILEO TYPE ELECTROLYSIS EXPERIMENTS #7 AND #5, BASED ON CR-39 TRACK DETECTOR RECORD

CR-39 TRACK DETECTORS IN COLD FUSION EXPERIMENTS: REVIEW AND PERSPECTIVES. A. S. Roussetski

COMPARISON OF COMPUTER CODES APPLICABILITY IN SHIELDING DESIGN FOR HADRON THERAPY FACILITIES *

Dosimetry for space radiation in ISS lifescience experiments using PADLES system

Researchers at the University of Missouri-Columbia have designed a triple crystal

Keywords: experimental verification; LiF:Mg,Cu,P; lithium fluoride; radial dose distribution

Today, I will present the first of two lectures on neutron interactions.

STUDY ON THE ENERGY RESPONSE OF PLASTIC SCINTILLATION DETECTOR TO MEV NEUTRONS ABSTRACT

Stability of Semiconductor Memory Characteristics in a Radiation Environment

Characterization of the 3 MeV Neutron Field for the Monoenergetic Fast Neutron Fluence Standard at the National Metrology Institute of Japan

Radionuclide Imaging MII Detection of Nuclear Emission

PERSONNEL DOSE EQUIVALENT MONITORING AT SLAC USING LITHIUM-FLUORIDE TLD S*

The MIT Nuclear Products Generator for development of ICF diagnostics at Omega / Omega EP and the NIF

International Journal of Scientific & Engineering Research, Volume 5, Issue 3, March-2014 ISSN

Nuclear Science and Engineering Institute, University of Missouri, USA and Sidney Kimmel Institute for the Nuclear Renaissance

Specific Accreditation Criteria Calibration ISO/IEC Annex. Ionising radiation measurements

CALIBRATION OF SCINTILLATION DETECTORS USING A DT GENERATOR Jarrod D. Edwards, Sara A. Pozzi, and John T. Mihalczo

Chapter V: Interactions of neutrons with matter

STUDY ON IONIZATION EFFECTS PRODUCED BY NEUTRON INTERACTION PRODUCTS IN BNCT FIELD *

Improvement of depth resolution of VEPAS by a sputtering technique

Neutron Interactions with Matter

Calculations of Photoneutrons from Varian Clinac Accelerators and Their Transmissions in Materials*

Hands on LUNA: Detector Simulations with Geant4

Some problems to be solved for automatic analysis of a CR-39 nuclear track detector in space radiation

PoS(idm2008)010. The PICASSO Dark Matter Search Project. A. Davour for the PICASSO collaboration Queen s University

Determination of the Neutron Component of the Cosmic Radiation Field in Spacecraft using a PADC Neutron Personal Dosemeter

CHARGED PARTICLE INTERACTIONS

Measurement ofdepth-dose distribution ofprotons by an imaging plate

GLOSSARY OF BASIC RADIATION PROTECTION TERMINOLOGY

Volume 1 No. 4, October 2011 ISSN International Journal of Science and Technology IJST Journal. All rights reserved

Radiation protection issues in proton therapy

INFLUENCE OF EXPOSURE GEOMETRY ON THE RESPONSE OF CR39 SSNT RADON DETECTORS *

Measurements of Radiation Doses Induced by High Intensity Laser between and W/cm 2 onto Solid Targets at LCLS MEC Instrument

Basics and Means of Positron Annihilation

Characterization of Low-Energy (6-30 kev) Response of Polish TLDs (MTS-N, MCP-N) with Synchrotron Radiation and Determination of Some TLD Quantities.

neutron building Project Title: Moderator design of RANS2 and investigating of radiation equivalent dose for Name: Sheng Wang

Measurement of the n_tof beam profile in the second experimental area (EAR2) using a silicon detector

SCINTILLATION DETECTORS & GAMMA SPECTROSCOPY: AN INTRODUCTION

Bubble Detector Characterization for Space Radiation

Lab1. Resolution and Throughput of Ion Beam Lithography.

SIMULATION OF THE THERMAL NEUTRON SEMICONDUCTOR DETECTOR RESPONSE USING MCNPX CODE

Proton and neutron radiation facilities in the PS East hall at CERN

Measurements with the new PHE Neutron Survey Instrument

Track Etch Detectors (TED)

NUCL 3000/5030 Laboratory 2 Fall 2013

CHARACTERIZATION OF A RADIATION DETECTOR FOR AIRCRAFT MEASUREMENTS

SILVER NEUTRON ACTIVATION DETECTOR FOR MEASURING BURSTS OF 14 MEV NEUTRONS

Neutron Spectrometry in Mixed Fields: Characterisation of the RA-1 Reactor Workplace

WM 07 Conference, February 25 March 01, 2007, Tucson, AZ

A POSITION SENSITIVE ALPHA PARTICLE DETECTOR BASED ON A LYSO CRYSTAL AND A MICRO-PIXEL AVALANCHE PHOTODIODE

Commissioning of the Beta Secondary Standard (BSS2)

Transcription:

Radiation Protection Dosimetry (2007), Vol. 126, No. 1 4, pp. 278 283 Advance Access publication 23 May 2007 doi:10.1093/rpd/ncm058 NOVEL Al 2 O 3 :C,Mg FLUORESCENT NUCLEAR TRACK DETECTORS FOR PASSIVE NEUTRON DOSIMETRY G. Jeff Sykora 1, Mark S. Akselrod 1, *, M. Salasky 2 and Stephen A. Marino 3 1 Landauer, Inc., Stillwater Crystal Growth Division, 723 1 2 Eastgate, Stillwater, OK 74074, USA 2 Landauer Inc., 2 Science Rd., Glenwood, IL 60425, USA 3 RARAF Columbia University, 136 S. Broadway, Irvington, NY 10533, USA The latest advances in the development of a fluorescent nuclear track detector (FNTD) for neutron and heavy charged particle dosimetry are described and compared with CR-39 plastic nuclear etched track detectors (PNTDs). The technique combines a new luminescent aluminium oxide single crystal detector (Al 2 O 3 :C,Mg) with an imaging technique based on laser scanning and confocal fluorescence detection. Detection efficiency was obtained after irradiations with monoenergetic neutron and proton beams. Dose dependences were measured for different configurations of the detectors exposed in fast- and thermalneutron fields. A specially developed image processing technique allows for fast fluorescent track identification and counting. The readout method is non-destructive, and detectors can be reused after thermal annealing. INTRODUCTION Passive nuclear track detectors are attractive for neutron dosimetry because they have 100% n/g discrimination. For instance, CR-39 plastic nuclear track detectors (PNTD) (1) have high sensitivity, but are not reusable, require long processing time and extensive chemical etching. Recently, Landauer developed a novel passive fluorescent nuclear track detector (FNTD) based on single aluminium oxide crystals doped with carbon and magnesium and having aggregate oxygen vacancy defects (Al 2 O 3 :C,Mg) (2 4).The newly developed FNTDs are more in common with CR-39 PNTDs, in that individual particle tracks can be imaged and counted and particle trajectories can be traced through the volume of the detector. This new FNTD technology is capable of optical and non-destructive detection of charged particles with linear energy transfer (LET) in water as low as 0.5 kev mm 21 while maintaining the ability to measure charged particles with higher LET. Diffraction-limited optical resolution of the method allows detection of high doses and fluences up to 10 7 cm 22 without saturation. The detectors can be completely erased using thermal annealing and reused. In comparison with optically stimulated luminescent detectors (OSLD), the new detectors use very deep traps and thus are very thermally and optically stable and do not require protection from visible light. Presented at the 10th International Symposium on Neutron Dosimetry, Uppsala, Sweden 12 16th June 2006, Paper B1-14. *Corresponding author: makselrod@landauerinc.com MATERIALS AND METHODS The FNTD is made of aluminium oxide single crystal doped with carbon and magnesium (Al 2 O 3 :C,Mg). As-grown or annealed crystals contain high concentrations of aggregate F 2þ 2 (2Mg)-colour centres that are believed to consist of two oxygen vacancies charge compensated by two Mg ions. Details of spectroscopic properties of the new crystals can be found elsewhere (5). Laser-induced fluorescence in this crystal can be stimulated with a 635-nm red laser diode without photoionisation of the colour centres, thus allowing non-destructive readout. Luminescence decay time of the new colour centre is almost 1 million times faster than that of the F-centre in Al 2 O 3 :C OSL material, making it possible to perform fast and non-destructive imaging of the crystal. For this study, 50 samples were cut from Al 2 O 3 :C,Mg crystals along the optical axis into small rectangular plates (6 10 1mm 3 ) and polished on their large sides. Irradiations with monoenergetic neutrons and protons were performed at the Radiological Research Accelerator Facility (RARAF) of Columbia University. Twenty-seven bare detectors without any converter on them were exposed to protons to a fluence of around 2 10 4 mm 22 with energies of 0.3, 0.59, 1.5 and 2.9 MeV. Most of the proton irradiations were performed at normal angle of incidence to the detector surface, and several samples were irradiated with 1.5-MeV protons at 308, 608 and 908. Sixteen detectors were also irradiated at RARAF with monoenergetic neutrons. Neutrons with energy of 0.2, 0.5, 1.0 and 2.0 MeV were produced through T(p,n) 3 He reaction, 6-MeV neutrons were produced by D(d,n) 3 He reaction and 14-MeV # The Author 2007. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oxfordjournals.org

NOVEL Al 2 O 3 :C,Mg FLUORESCENT NUCLEAR TRACK DETECTORS neutrons were generated by T(d,n) 4 He reaction using a Van de Graff proton accelerator. All detectors for neutron irradiations had only two converters: 1 mm polyethylene (PE) and 1 mm 10 B-loaded Teflon (10% by weight) having area of 10 by 10 mm 2, placed directly on top of them. Dose dependences were obtained after irradiation with fast and thermal neutrons from calibrated Am Be neutron sources at the Landauer irradiation facility. Delivered H* p (10) doses were in the range from 0.3 to 300 msv for fast neutrons and from 0.3 to 10 msv for thermal neutrons. Irradiations with fast neutrons were performed using a 185 MBq Am Be source in two geometries: free-in-air at 20 cm from the source and on a 30 30 15-cm 3 PMMA phantom at 50 cm distance. Thermal neutrons were produced by a 37-MBq Am Be source moderated by 180 mm of paraffin. All detectors exposed in this experiment to both fast and thermal neutrons had the same configuration with three areas covered by 1 mm of PE converter, 1 mm of 10 B-loaded Teflon and a 6 LiF TLD-600 chip having 4.5 mm in diameter. Optical imaging of the detectors was performed using a new experimental set-up custom-built at Stillwater R&D laboratories of Landauer. The system is based on a classical scheme of the laser scanning fluorescence confocal microscope and is described elsewhere (2). The detector is first scanned perpendicular to the detector surface using a piezoelectric actuator to detect the surface position with an accuracy of 0.1 mm and then imaged at the desired depth usually at 1 mm below the surface. An example of the image obtained after fast-neutron irradiation is presented in Figure 1. Multiple images were obtained from FNTD behind each of the three converters. The imaged area has dimensions of 150 150 mm 2. The number of acquired images depends on the density of tracks and adaptively varies between 1 and 25 for each of the three converter areas. The images are processed and tracks are identified and counted either by an automatic track processing program synchronously with scanning of the next image or manually from the saved file to ensure the quality of automatic processing. Confocal fluorescence microscopy allows for stimulation of a highly localised volume of the crystal and diffraction-limited spatial resolution. Because of radiochromic transformations the intensity of fluorescence induced within the track volume is stronger than that induced outside the track. The materials and methods used for the CR-39 etched track detectors from Landauer tested in this study are similar to that described in detailed elsewhere (1). Figure 1. Image of recoil proton tracks obtained from Al 2 O 3 :C,Mg FNTD in fluorescent contrast using confocal laser scanning system. The tracks were produced behind the PE converter using fast neutron irradiation from Am Be source. Image size is 100 100 mm 2. 279

RESULTS Proton irradiations The dose of fast neutrons is measured in FNTD technology through detection of recoil protons generated by neutrons in a PE converter. Thus, investigation of the FNTD detection efficiency and fluorescence track amplitude as a function of proton energy and angle of incidence is critically important. The range of protons in Al 2 O 3 was also compared with that calculated using SRIM-2003 software (6). Comparison of delivered fluences that were calculated from the accelerator instrumentation data and the measured FNTD track density yields the detector efficiency that is practically 100% for protons within the investigated energy range. Discrepancies between delivered and measured fluences are between 0.3 and 8% for different samples and might be caused by the errors in irradiation time and beam instrumentation coupled with statistical fluctuations of the requested low fluences. Fluorescence amplitudes of tracks induced by monoenergetic protons were investigated as a function of proton energy. A special automatic image processing routine was developed in LabView to process a large number of tracks for each sample. Figure 2 shows the dependence of amplitude on proton energy. Histograms of track amplitude distributions are shown on the insert. The spread in amplitudes is probably due to two main factors: an uneven distribution of colour centres within the detector and the spread in proton energies. As the LET 1 of the protons decreases with increasing energy, the amplitudes of the tracks start to reach saturation. In the same experiment CR-39 detectors were exposed. As one can see from Figure 2, the pit diameter of proton tracks decreases exponentially with the energy and does not change much for G. JEFF SYKORA ET AL. energies above 2 MeV. For FNTD, the measured fluorescent track diameter does not change with the proton energy because the track core is very small (on the order of a few nanometers) compared with the spot size of the excitation beam (l/na). All tracks appear to be 1 mm in diameter for protons penetrating perpendicular to the detector surface and 1 mm in width for the angled tracks. The length of the imaged track increases linearly with the angle of incidence making it easy to determine the angle. The confocal geometry of the optical readout system allows the detector to be imaged at multiple depths and provides information about the particle range (3).Inthisstudy,3-Dimages of 1.5-MeV proton tracks penetrating the detector were also acquired and a range of 16.0 + 0.5 mm was determined. Calculation using SRIM-2003 (6) gave us 16.49 mm, in good agreement with the measured value. Detector responses to monoenergetic neutrons The neutron detection efficiency as a function of neutron energy for both CR-39 and FNTD is shown in Figure 3. Two competing processes affect the efficiency of FNTD. At low energies, a limiting factor is a small recoil proton range, whereas at higher neutron energies (n,p), scattering cross section decreases as 1/ p E. The maximum recoil proton energy from a PE converter for a 0.2-MeV neutron irradiation is 0.2 MeV, and the maximum proton range in Al 2 O 3 as calculated by SRIM 2003 (6) is only 1.08 mm. Short range of low energy recoil protons makes it difficult to detect tracks using fluorescence technique. In the case of FNTD, the detection efficiency in tracks per incident neutron increases to a maximum value at 6 MeV (Figure 3), in correspondence with the earlier CR-39 measurements of Benton et al. (1). Figure 2. Comparison of track parameters for CR-39 plastic nuclear track detector (track diameter) and Al 2 O 3 :C,Mg FNTD (fluorescence amplitude) and histogram of distribution of fluorescent amplitudes for three proton energies. 280

NOVEL Al 2 O 3 :C,Mg FLUORESCENT NUCLEAR TRACK DETECTORS Figure 3. Detection efficiency as a function of energy for monoenergetic neutrons for CR-39 PNTD and Al 2 O 3 :C,Mg FNTD. CR-39 detectors from Landauer tested in this study show a peak detection efficiency at 2 MeV with rapid decrease in efficiency at higher energy. An earlier version of Al 2 O 3 :C,Mg crystals with detection efficiency lower than CR-39 was used in this test. The FNTDs used later for the dose dependencies described below show almost three times higher detection sensitivity, as was confirmed by additional tests performed after 0.2- and 0.5-MeV neutron irradiations at RARAF. Neutron dose dependence Multiple images were automatically acquired from each detector from the areas behind all three converters. Dose dependences are presented in Figure 4 and show good linearity within three orders of investigated dose range for fast neutrons. There is no significant difference in the sensitivity of FNTD behind the PE converters between irradiations performed in-air and on-phantom (Figure 4a), which indicates that albedo neutrons do not affect the sensitivity of the detectors to fast neutrons. The obtained sensitivity of 21.5 tracks mm 22 msv 21 is consistent with our preliminary results (2). In comparison, the sensitivity of CR-39 to fast neutrons is 12.1 tracks mm 22 msv 21. The sensitivity of FNTDs to thermal neutrons with 6 LiF converter as determined from the slope of the dose dependence in Figure 4d is 6500 tracks mm 22 msv 21, which is also consistent with the sensitivity reported previously. The track density per 1 msv of dose for a thermal component of FNTD obtained using 6 LiF is 300 times higher than for a PE component which makes it almost insensitive to fast neutrons. As a result, it was concluded that the PE component of the detector is sensitive only to fast neutrons and the 6 LiF part provides response exclusively to a thermal component of the field. 10 B-loaded Teflon converter gave us almost 100 times lower track density (Figure 4d). Significant numbers of tracks measured behind the PE converters after irradiations with the paraffin-moderated Am Be source (Figure 4d) prove that there is still a large flux of fast neutrons in the field. Using the fast neutron sensitivity of 21.5 mm 22 msv 21 obtained above from Figure 4a, it was calculated that the dose equivalent of fast neutrons in the thermal field exceeds five times the dose equivalent for thermal neutrons. In turn, detectors behind 6 LiF and 10 B converters allowed us to estimate the contribution of thermal dose during irradiations with fast neutrons free-in-air and onphantom due to scattering and albedo neutrons (Figure 4b and c). Using the sensitivity to thermal neutrons of 6500 mm 22 msv 21, it was calculated that the contribution of thermal neutrons during free-in-air irradiations is only 0.1%, whereas during on-phantom irradiations their contribution increased almost 10 times. Scattering of fast neutrons from the concrete walls (3 4 m distance) and the ceiling (1.5 m distance) should contribute at least 5% of the total dose. Most of these scattered neutrons are epithermal and are not detected by FNTD in the current configuration. Another important observation is the difference in track density for 6 LiF and 10 B converters obtained after irradiations in different neutron fields 281

G. JEFF SYKORA ET AL. (see Figure 4b d). For neutrons moderated by paraffin with a large thermal component, a 6 Li converter provides significantly higher response than the 10 B converter (Figure 4d), whereas for free-in-air fast neutron irradiations their sensitivity is almost equal (Figure 4b). The albedo configuration during on-phantom irradiations shows the intermediate situation (Figure 4c). The nuclear reaction and product energies for 6 Li(n,a) and 10 B(n,a) are as follows: 6 Li þ 1 n! 4 Heð2:05MeVÞþ 3 Hð2:73MeVÞ 10 B þ 1 n! 7 Li ð0:84mevþþ 4 Heð1:47MeVÞ ð1þ The thermal neutron capture cross section for 10 B is about four times that for 6 Li, but the Q value of the 6 Li(n,a) reaction is about twice that of the 10 B(n,a) reaction. Because both products of the 6 Li(n,a) reaction have higher energies, their range is longer and thus easier to detect using FNTD than the products from the 10 B(n,a) reaction. The tritium ion has a range of 24 mm inal 2 O 3 whereas the alpha particle has a range of 4 mm, as calculated by SRIM 2003 (6).In turn, the range of alpha particles produced in the 10 B(n,a) reaction is only 2.9 mm and explains a low detection efficiency of this converter. It has been concluded that an element with high 6 Li content is a better choice for a converter of thermal neutrons to be used with FNTD. CONCLUSIONS New fluorescent nuclear track detectors based on Al 2 O 3 :C,Mg single crystals were tested and calibrated in parallel with CR-39 PNTD in different neutron fields and with monoenergetic protons. Good fast to thermal neutron discrimination was demonstrated. The sensitivity and efficiency for these two types of neutron detectors was shown to be comparable while continuing to exhibit 100% n/g discrimination. At the same time, FNTDs do not require long chemical etching, can measure significantly higher neutron dose and proton fluence due to small track size and are completely reusable and allow for fast automated image processing. Figure 4. Dose dependences of track densities for Al 2 O 3 :C,Mg FNTDs covered by three different converters (polyethylene, 6 LiF chip and 10 B-loaded Teflon) and irradiated with unmoderated and moderated paraffin Am Be sources. AKNOWLEDGEMENTS The work of S.A.M. at RARAF of Columbia University was partially supported by Department of Energy (DOE) grant #DE-FG02-01ER63226 and by National Institute of Biomedical Imaging and Bioengineering (NIBIB) grant #8P41EB002033-011). We also want to thank our colleagues at 282

Landauer: T. H. Underwood, K. Dillin and J. Allen for their contributions to the development of crystal growth technology and sample preparation. REFERENCES NOVEL Al 2 O 3 :C,Mg FLUORESCENT NUCLEAR TRACK DETECTORS 1. Benton, E. V., Oswald, R. A., Frank, A. L. and Wheeler, R. V. Proton recoil neutron dosimeter for personnel monitoring. Health Phys. 40, 801 809 (1981). 2. Akselrod, M. S., Yoder, R. C. and Akselrod, G. M. Confocal Fluorescent Imaging of Tracks from Heavy Charged Particles Utilizing New Al 2 O 3 :C,Mg crystals. Rad. Prot. Dosim. 119, 357 362 (2006). 3. Akselrod, G. M., Akselrod, M. S., Benton, E. R. and Yasuda, N. A Novel Al 2 O 3 Fluorescent Nuclear Track Detector for Heavy Charged Particles and Neutrons. Nucl. Instr. Methods. B247, 296 306 (2006). 4. Akselrod, M. S. and Akselrod, A. E. New Al 2 O 3 :C,Mg crystals for radiophotoluminescent dosimetry and optical imaging of tracks produced by heavy charge particles, Radiat Prot. Dosim. 119, 218 221 (2006). 5. Akselrod, M. S., Akselrod, A. E., Orlov, S. S., Sanyal, S. and Underwood, T. H. Fluorescent aluminum oxide crystals for volumetric optical data storage and imaging application. J. Fluoresc., 13, 503 511 (2003). 6. Ziegler, J. F. and Biersack, J. P. SRIM-2003.20 software package. Available on http://www.srim.org/. 283