E C t y p e - e x a m i n a t i o n C e r t i f i c a t e

Similar documents
E v a l u a t i o n C e r t i f i c a t e

A compression load cell, with strain gauges, tested as a part of a weighing instrument. Manufacturer : Molen or Precia Molen.

ACCEPTANCE PROCEDURE FOR ROMET ROTARY METER BODIES AND/OR MECHANICAL NON-CONVERTING AND CONVERTING MODULES

Fine Tuning Coriolis Flow Meter Calibrations Utilizing Piece- Wise Linearization

Measuring Instruments Directive (MID) MID/EN14154 Short Overview

Linearity of Coriolis Flowmeters at Full Scale Value. Dr. Jesús Aguilera - Endress + Hauser Paul Ceglia - Endress + Hauser

CORIOLIS MASS FLOW METERS FOR GAS AND LIQUID MEASUREMENT. Michael Keilty (Presented by Hubbard Donald) Endress + Hauser Flowtec AG

Test report CVN Project number Page 2 of 2

9.1 Compatibility of modules for nonautomatic weighing instruments (NAWIs) Common requirements

Guidelines for the Selection and Operation of Provers with Micro Motion ELITE Coriolis Flow Meters

KNOWLEDGE

Infrared Thermometer Calibration A Complete Guide

NEW VSL Conditioning plate!

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

Evaluating New Generation Vibrating Tube Sensor for Density Measurement under Process Conditions

KNOWLEDGE. Allow Smart Meter Verification to Reduce your Proving and Proof-Test Costs. Abstract. Introduction

Load Cell Approval Field and Laboratory Evaluation Manual

ISO INTERNATIONAL STANDARD

Addendum to ARI Standard , Air Terminals September 2002

OIML R RECOMMENDATION. Edition 2006 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION. Instruments for measuring the areas of leathers

Calibration of Temperature Block Calibrators

Project PAJ2 Dynamic Performance of Adhesively Bonded Joints. Report No. 3 August Proposed Draft for the Revision of ISO

Guidelines on the Calibration of Automatic Instruments for Weighing Road Vehicles in Motion and Measuring Axle Loads AWICal WIM Guide May 2018

EUROPEAN COMMISSION. Brussels, XXX [ ](2015) XXX draft ANNEX 1 ANNEX

Laboratory Evaluation Report for: Dielectric Pipe Unions

Coriolis Mass Flowmeter. (MCM Series) 100% Customer Satisfaction MAXIFLO TM. Coriolis Mass Flowmeter Series MCM

Custody Transfer Measurement and Calibration Round Robin Testing for Natural Gas with Coriolis Meters

CERTIFICATE OF CALIBRATION

REPORT ON API 21.1 EGM STANDARD Brent E. Berry ABB-Totalflow

CALIBRATION CERTIFICATE # 503

Certificate: / 29 April 2014

ANNEX to IECEx Certificate

EUROPEAN COMMISSION. Brussels, XXX D046374/04 [ ](2016) XXX draft ANNEX 1 ANNEX

CNG measuring systems for vehicles

Sonic Anemometer Classification

INTERNATIONAL STANDARD

EA Guidelines on the Calibration of Temperature Indicators and Simulators by Electrical Simulation and Measurement

- Page 1 of 11 - QC

SUBPART MULTIYEAR CONTRACTING (Revised December 19, 2006)

Traceable Mass Determination and Uncertainty Calculation

Standard Practices for Air Speed Calibration Testing

ED 701 General Industry Pressure Transmitter

Precision Leaded Resistors

Understanding the Uncertainty when Using a Type Coefficient for Temperature Corrections of a Coriolis meter. Dean M. Standiford Emerson-Micromotion

Test Report EN (2008)

ADI 2040 Process Analyzer

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

REPORT NUMBER: MID-001 ORIGINAL ISSUE DATE: April 22, 2016 REVISED DATE: NA. EVALUATION CENTER Intertek 8431 Murphy Drive Middleton, WI 53562

Test Report No.: GZHL HM Date: Aug 08, 2016 Page 1 of 10

Expedited Filing Draft August 22, 2017

TEST REPORT ENVIRONMENTAL TESTING

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

Operating Instructions for Digital Manometer. Model: MAN-SD

Verification for Non-Automatic Weighing Instruments (NAWI)

REVISIONS SYMBOL DESCRIPTION DATE APPROVAL

Today s menu. Last lecture. Measurement of volume flow rate. Measurement of volume flow rate (cont d...) Differential pressure flow meters

Test Report. Report No.: EED35I Page 1 of 12. Customer : Revolution Lighting Technologies : 4139 Guardian Street, Simi Valley, CA93063

After publication, this Indian Standard will supersede the following Indian Standards:

ISO INTERNATIONAL STANDARD. Thermal performance of windows, doors and shutters Calculation of thermal transmittance Part 1: Simplified method

ISO INTERNATIONAL STANDARD. Test code for machine tools Part 5: Determination of the noise emission

PHD71NQ03LT. N-channel TrenchMOS logic level FET. Simple gate drive required due to low gate charge

Determination of particle size distribution Single particle light interaction methods. Part 4:

CoriolisMaster FCB/FCH150 and FCB/FCH450 Simultaneous recording of flow rate and density / concentration for the food and beverage industry

Installation guide 862 MIT / MIR

N-channel enhancement mode Field-Effect Transistor (FET) in a small SOT23 (TO-236AB) Surface-Mounted Device (SMD) plastic package using

Review of Anemometer Calibration Standards

Relative pressure transmitter type 520

VERIFICATION OF TAPPING MACHINES. Håkan Andersson

ISO 3741 INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Paints and varnishes Determination of density Part 3: Oscillation method

Manual of Petroleum Measurement Standards Chapter 5 Metering

Integrated Circuits Thermal Test Method Environment Conditions - Natural Convection (Still Air)

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6712/ARL-SA6713 Revision 0 ARL

Uncertainties associated with the use of a sound level meter

ISO INTERNATIONAL STANDARD. Metallic materials Vickers hardness test Part 3: Calibration of reference blocks

Certificate: / 30. April 2015

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

Weathertightness testing of Solar Slate Plate to MCS012. Prepared for: Michael Share. Solar Slate Plate. 24 th June Test report number

ORGANISATION INTERNATIONALE DE MÉTROLOGIE LÉGALE INTERNATIONAL RECOMMENDATION

Temperature control for Varian Cary line of UV/Vis Spectrophotometers and the Eclipse Fluorometer

DOG-1/-3. Oscillation Flowmeter. for gases. Measuring ranges: m 3 /h air : 120 C. p max. : PN 40; t max

S95.3U01 / S95.3U11. Head mounted temperature transmitters, programmable, Pt 100 (RTD), thermocouples, electrical isolation

N-channel TrenchMOS logic level FET

5SJ4...-.HG Circuit Breakers to IEC and UL 489

APPLICATION OF DENSITOMETERS TO LIQUID MEASUREMENT Class #

ISO INTERNATIONAL STANDARD

SHANGHAI MYLCH WINDOWS & DOORS THERMAL PERFORMANCE TEST REPORT

Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure

CERTIFICATE of Product Conformity (QAL1 )

PMWD16UN. 1. Product profile. 2. Pinning information. Dual N-channel µtrenchmos ultra low level FET. 1.1 General description. 1.

PRELIMINARY DRAFT INDIAN STANDARD METHOD FOR CALIBRATION AND CLASSIFICATION OF TORQUE MEASURING DEVICES INCLUDING TORQUE WRENCH TESTER

2N7002T. 1. Product profile. 2. Pinning information. N-channel TrenchMOS FET. 1.1 General description. 1.2 Features. 1.

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

Test Report No.: GZHL HM-01 Date: Aug 16, 2016 Page 1 of 10

2.1. Accuracy, n- how close the indication of the thermometer is to the true value.

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

ISO INTERNATIONAL STANDARD

ADM-Aeolus Science and Cal/Val Workshop

Technical Procedure for General Laboratory Equipment

Transcription:

E C t y p e - e x a m i n a t i o n C e r t i f i c a t e Page 1 of 1 Issued by Manufacturer NMi Certin B.V., designated and notified by the Netherlands to perform tasks with respect to conformity modules mentioned in article 9 of Directive 2004/22/EC, after having established that the Measuring instrument meets the applicable requirements of Directive 2004/22/EC, to: Emerson Process Management Flow B.V. Neonstraat 1 6718 WX Ede The Netherlands Measuring instrument A Coriolis Gas Meter Brand Type : Micro Motion : CMFxxxy (see paragraph 1.2 for the meaning of xxx, CNG050 and DS600, with MVD electronics (see paragraph 1.1 for details) Destined for the measurement of Valid until 8 May 2017 : fuel gases, with an actual density of 4 kg/m 3 and higher, and supercritical ethylene with a density up to 450 kg/m 3 : see paragraph 1.2 of the description Q min - Q max Accuracy class : Class 1,0 Environment classes : M3 / E3 Q min - Q max : see paragraph 1.2 of the description Temperature range gas : -40 C / +150 C for CMF200/300/400/HC2/HC3/HC4/DS600; -10 C / +50 C for CMF025/050/100; -25 C / +55 C for CNG050. Ambient temperature range : -40 C / +55 C Further properties are described in the annexes Description T10020 revision 4 Documentation folder T10020-4 Remarks This revision replaces the earlier version(s) including its documentation folder. Issuing Authority NMi Certin B.V., Notified Body number 0122 1 March 2013 1 C. Oosterman Head Certification Board NMi Certin B.V. Hugo de Grootplein 1 3314 EG Dordrecht The Netherlands T +31 78 6332332 certin@nmi.nl www.nmi.nl This document is issued under the provision that no liability is accepted and that the applicant shall indemnify third-party liability. The designation of NMi Certin BV.as Notified Body can be verified at http:// ec.europa.eu/enterprise/newapproach/nando/ Parties concerned can lodge objection against this decision, within six weeks after the date of submission, to the general manager of NMi (see www.nmi.nl). Reproduction of the complete document only is permitted. 101

Page 1 of 6 1 General information about the gas meter All properties of the gas meter, whether mentioned or not, shall not be in conflict with the legislation. This EC type-examination certificate confirms that the involved equipment complies with the applicable essential requirements of the European directive 2004/22/EC (MID). Beside the measurement of mass the coriolis meter is capable of measuring volume as well. However, only the measurement of mass is part of this EC-type examination Certificate. 1.1 Essential parts Measurement sensor Essentially, the measurement sensor consists of a housing in which two parallel measuring tubes are mounted. On the measurement tubes three coils are mounted: one drive-coil and two pick-off coils. The drive coil is controlled by an external device and sets the measurement tubes in a vibrating motion. The pick-off coils generate signals representative for the frequency of motion of the measurement tubes. The resonant frequency depends, among other things, on the density of the gas in the measurement tubes. The time difference between the signals from both pick-off coils depends on the mass flow of the gas through the measurement tubes. Processing of the measurement signals is performed by the same external device that controls the drive coil. The different sensors are described in the documentation no. 10020/0-02, 10020/0-04, 10020/2-02, 10020/4-01 and 10020/4-02. The CMF400 sensor is produced including the changes mentioned in documentation no. 10020/0-05. In- and outputs The measurement sensor is equipped with several in- and outputs: - Drive current input, for setting the measurement tubes in a vibrating motion - 2 Pick-off outputs, generating sinusoidal millivolt signals - One 3-wire Pt-100 output, for the measurement of the tube temperature 1.1.1 Core processor, model 700 or 800 The output of the sensor is processed by a core processor, model 700 or 800, as described in the Evaluation Certificate no. TC7057. 1.1.2 Flow transmitter, model 1700 or 2700 A flow transmitter, model 1700 or 2700, is connected to the core processor. The flow transmitter is described in the Evaluation Certificate no. TC7057, but with the following aspects: - markings as described in paragraph 1.3.2; - only the indication of mass via the Total and Inventory registers is used for custody transfer purposes; - indication as described in paragraph 1.5.1; - settings as described in paragraph 1.5.2.

Page 2 of 6 1.1.3 Flow transmitter, model 2 A flow transmitter, model 2, is connected to the core processor. The flow transmitter is described in the Evaluation Certificate no. TC7057, but with the following aspects: - markings as described in paragraph 1.3.2; - only the double pulse output, set to mass, is used for custody transfer purposes and is connected to a remote MID approved indicating device/flow computer; - indication as described in paragraph 1.5.1; - settings as described in paragraph 1.5.2. 1.1.4 Flow transmitter, model 3 or 3700 A flow transmitter, model 3 or 3700, is connected to the core processor. The flow transmitter is described in the Evaluation Certificate no. TC7057, but with the following aspects: - markings as described in paragraph 1.3.2; - only the indication of mass via the Total and Inventory registers is used for custody transfer purposes; - indication as described in paragraph 1.5.1; - settings as described in paragraph 1.5.2. 1.2 Essential characteristics 1.2.1 Flow characteristics The meter has the following flow characteristics: Model CMF025 CMF050 CMF100 CMF200 CMF300 CMF400 maximum Q max [kg/h] 19 x actual density [kg/m 3 ] Q t minimum Q min [kg/h] diameter in/outlet [mm] A/M/L/S ( maximum p max [bar] B/C/E/H/P/Y ( minimum actual density [kg/m 3 ] 3 6 103 190 4 60 x actual density [kg/m 3 ] 15 12 103 185 5 175 x actual density [kg/m 3 ] 60 25 100 170 6,9 425 x actual density [kg/m 3 ] 200 50 108 190 9,5 1.175 x actual density [kg/m 3 ] 80 119 185 8,6 3.150 x actual density [kg/m 3 ] 1/5 Q max 9.000 100 103 197 *) 57,2 DS600 S 3.300 x actual density [kg/m 3 ] 6. 150 43 N/A 39,4 CNG050 4620 115 12 345 - CMFHC2 CMFHC3 CMFHC4 3.571 x actual density [kg/m 3 ] 6.182 200 102 206 34,7 5.904 x actual density [kg/m 3 ] 12.364 200 102 206 41,9 9.244 x actual density [kg/m 3 ] 18.545 250 102 206 40,2 Remarks: - *) with the exception to the value as indicated in the table the maximum p max value of the CMF400P is 205 bar. - Indicates the type of material the meter is build of.

Page 3 of 6 - The Q max is limited to a maximum speed of the flow in the sensor. The stated formula reflects the calculation of the value for Q max based on the maximum speed, while using the actual density. - If the meter is used in a specific density range, the minimum density is used to calculate the value for Q max. - Turn down ratio (Q max to Q min ) 20:1. - All sensors can be used bi-directional. 1.2.2 Volume indication at base conditions For pure gases mass can be converted to a volume at base conditions using a fixed density at base conditions. The applied fixed density and the base conditions are stated on the nameplate or close to the indicator, for example Nm 3 @ xx C and yy bar(a) with zzzz kg/m 3. 1.2.3 Pressure correction, Temperature correction and Velocity of sound correction Pressure correction A) Depending on the sensor characteristics, a dynamic pressure correction by means of pressure transmitter is required when the pressure variation in the final application has an effect of more than 1/10 of the Maximum Permissible Error (MPE) for that application. B) When the sensor is calibrated at another average pressure then the average pressure in the final application (e.g. water calibration at low pressure), the corresponding pressure effect due to the pressure difference has to be considered. When the pressure effect is more than 1/10 of the MPE, then a pressure correction is required, either static (configured in electronics) or dynamic (pressure transmitter). C) The pressure coefficient values for the different sensors and the pressure values at which the correction has to take place for the different accuracy classes are mentioned in the documentation no. 10020/4-03. Temperature correction In the flow transmitter (see Evaluation Certificate TC7057) a temperature correction is applied depending on the connected sensor type, according to document no. 10020/2-01 and 10020/4-04. Temperature correction for the sensor behaviour due to process temperature variations takes automatically place by default, based on the integral temperature sensor and the configured temperature coefficients in the electronics. The temperature dependency on mass flow is called mass Flow Temperature coefficient FT (in % per 100 C). Individual determination of the flow sensor Flow Temperature coefficient FT by the manufacturer is mandatory when the process temperature is above +100 C.

Page 4 of 6 Velocity of sound correction In the flow transmitter a velocity of sound correction can be applied depending on the connected sensor type, according to document no. 10020/4-05. The velocity of sound influences the mass output of the Coriolis meters that have high operating frequencies and/or large tube diameters. Correction takes automatically place by default, based on the measured density and the configured velocity of sound coefficients in the electronics. 1.2.4 Software In the Evaluation Certificate no. TC7057, paragraph 1.2, the approved software versions are stated. The software version is presented on the display. 1.3 Essential shapes 1.3.1 Nameplate sensor The nameplate of the sensor is bearing at least, good legible, the following information: - CE marking; - the type approval mark no. T10020; - name or trade mark of the manufacturer; - sensor type; - serial number and year of manufacture; - accuracy class; - Q max, Q t and Q min ; - temperature range of the sensor; - density range and/or pressure range; - indication of the flow direction; - information concerning possible bi-directional use. An example of the markings is shown in documents no. 10020/0-06 and T10020/4-07. 1.3.2 Nameplate flow transmitter The nameplate of the flow transmitter is bearing at least, good legible, the following information: - the type approval mark no. T10020; - name or trademark of the manufacturer; - transmitter type; - transmitter serial number; - sensor type; - sensor serial number; - year of manufacture; - ambient temperature range; - the remark Only the mass indication Total is used for custody transfer. or Only the mass indication Total / Inventory is used for custody transfer. An example of the markings is shown in documents no. 10020/0-07 and 10020/4-08. 1.3.3 Sealing: see chapter 2.

Page 5 of 6 1.4 Conditional parts 1.4.1 Housing The gas meter has a housing, which has sufficient tensile strength. 1.4.2 Transmission The transmission between the sensor and the flow transmitter is described in the Evaluation Certificate TC7057. 1.4.3 Outputs The characteristics of frequency and/or current outputs is presented on the display. 1.4.4 Outputs for an external flow computer An external flow computer can be connected to the flow transmitter, as indicated in the Evaluation Certificate no. TC7057. In that case the flow computer is connected to the transmitter module, using the available outputs of the transmitter module. The flow computer has to be approved via an EC-type examination Certificate. 1.5 Conditional characteristics 1.5.1 Register The measured quantity of gas is presented by the flow transmitter in such a way, that the following conditions are fulfilled: - the number of digits equals at least the quantity corresponding with 8.000 hours at the maximum flow rate; - the least significant digit shall not exceed the quantity of gas passed during one hour at Q min. In documentation no. 10020/4-06 the method for programming of the flow transmitter is described. 1.5.2 Settings The following items as stated in Evaluation Certificate no. TC7057, paragraph 1.5, are programmed in the flow transmitter: - security mode settings; - low flow cut off settings; - damping settings; - slug flow settings; - last measured value fault time out settings. 2 Seals 2.1 Sensor The sensor is not provided with seals. 2.2 Flow transmitter The flow transmitter is sealed according to the Evaluation Certificate no. TC7057.

Page 6 of 6 3 Conditions for conformity assessment - Verification procedure For the initial verification the NMi procedure C-SP-HW-280 is applied with the title Procedure C-SP-HW-280 for the MID conformity assessment for the Micro Motion Flow meter when used for custody transfer in gas applications (annex MI-002) and liquid applications (annex MI-005). The initial verification is based on: a water calibration, which includes: a zero mass flow setting at the water calibration facility a mass flow test a zero mass flow verification In the field: a zero mass flow setting, if needed a zero mass flow verification Note: a zero mass flow verification and an applicable density verification can also be used for subsequent verifications. This procedure is justified because of the fact that tests have proven that the mass accuracy on water is representative for mass accuracy on gases.