ICP-OES Application Note Number 35

Similar documents
The Investigation of Fertilizer Analyses Using Microwave Digestion and the Agilent 720-ES

Enhancing the productivity of food sample analysis with the Agilent 7700x ICP-MS

Ultra-fast determination of base metals in geochemical samples using the 5100 SVDV ICP-OES

Analysis of domestic sludge using the Agilent 4200 MP-AES

U.S. EPA SW-846 Method 6010C using the Prodigy High Dispersion ICP

Fast Analysis of Water Samples Comparing Axially-and Radially- Viewed CCD Simultaneous ICP-OES

Determination of major, minor and trace elements in rice fl our using the 4200 Microwave Plasma- Atomic Emission Spectrometer (MP-AES) Authors

U.S. EPA SW-846 Method 6010C Using the Prodigy7 High- Dispersion ICP Introduction. Application Note - AN1305. Experimental

Elemental analysis of river sediment using the Agilent 4200 MP-AES

Meeting the Challenges of Soil Analysis with the Avio 200 ICP-OES

Today s Agilent Solutions for Determining Heavy Metals in Food using Atomic Spectroscopy

Using FIMS to Determine Mercury Content in Sewage Sludge, Sediment and Soil Samples

OES - Optical Emission Spectrometer 2000

High-Speed Environmental Analysis Using the Agilent 7500cx with Integrated Sample Introduction System Discrete Sampling (ISIS DS)

Direct Analysis of Trace Metal Impurities in High Purity Nitric Acid Using ICP-QQQ

Analysis Repeatability of Trace and Major Elements in a Water Sample

Determination of Pb, Cd, Cr and Ni in Grains Based on Four Chinese National Methods via Zeeman GFAAS

Multi-Element Analysis of Petroleum Crude Oils using an Agilent 7900 ICP-MS

Hydride Generation for the Determination of As, Sb, Se and Bi Using the Teledyne Leeman Lab s Prodigy 7 ICP-OES

Determination of Impurities in Silica Wafers with the NexION 300S/350S ICP-MS

Simple, reliable analysis of high matrix samples according to US EPA Method 6020A using the Agilent 7700x/7800 ICP-MS

Thermo Scientific icap RQ ICP-MS: Typical limits of detection

The Agilent 7700x ICP-MS Advantage for Drinking Water Analysis

High-Throughput Semiquantitative Screening of Ambient Air Samples by ORS-ICP-MS and Integrated Sample Introduction System (ISIS) Application

Test Method: CPSC-CH-E

Current State of Extraction Don t Be Deceived! Sharon F. Webb, Ph.D. Director of Quality Program

Trace elemental analysis of distilled alcoholic beverages using the Agilent 7700x ICP-MS with octopole collision/ reaction cell

Determination of Chromium in Gelatin Capsules using an Agilent 7700x ICP-MS

SeCtiOn 5 [STOCK AND CUSTOM] Assurance. Multi-Element CLP Standards

Total Elemental Analysis of Food Samples for Routine and Research Laboratories, using the Thermo Scientific icap RQ ICP-MS

February 20, Joe Cerniglia The International Group for Historic Aircraft Recovery (TIGHAR) Job Number: S0CHG688. Dear Joe:

Direct Measurement of Metallic Impurities in 20% Ammonium Hydroxide by 7700s/7900 ICP-MS

Multi-Element Analysis of Cannabis using the Agilent 7800 ICP-MS

Analysis of high matrix samples using argon gas dilution with the Thermo Scientific icap RQ ICP-MS

Determination of trace elements in ultrapure semiconductor grade sulfuric acid using the Agilent 8900 ICP-QQQ in MS/MS mode

China Soil Pollution Survey: Elemental Analysis of Soil and Sediment Digests by ICP-MS

PRINCIPLE OF ICP- AES

Not Just for Paint Chips Anymore. High Throughput, Open Vessel Microwave Digestion of Matrices Requiring Moderate Conditions

Determination of Total Bromine and Iodine Emission Spectrometric Method (ICP-OES) EuSalt/AS

Determination of Phosphorus and Sulfur with Dynamic Reaction Cell ICP-MS

High Throughput Water Analysis using Agilent 7900 ICP-MS coupled with ESI prepfast

Product Safety Reference Manual. Book 5 - Laboratory Policies and Procedures C

Analysis of Trace Metal Impurities in High Purity Hydrochloric Acid Using ICP-QQQ

ICP-3000 Inductively Coupled Plasma Optical Emission Spectrometer

The Determination of Toxic, Trace, and Essential Elements in Food Matrices using THGA Coupled with Longitudinal Zeeman Background Correction

Multi Analyte Custom Grade Solution. Aluminum, Potassium, Magnesium, ANALYTE CERTIFIED VALUE ANALYTE CERTIFIED VALUE

OPTIMIZING METALS SAMPLE PREP

Thermo Scientific icap TQ ICP-MS: Typical limits of detection

METHOD 7060A ARSENIC (ATOMIC ABSORPTION, FURNACE TECHNIQUE)

Mercury, total-in-sediment, atomic absorption spectrophotometry, nameless, direct

Brooklyn College Department of Chemistry

Environmental Series - Trace contaminant analysis in brine using a Thermo Scientific icap 6000 Series Duo ICP

Analysis of mineral elements in wines using ICP-AES (inductively coupled plasma / atomic emission spectrometry) (Resolution Oeno 478/2013)

Rapid Analysis of High-Matrix Environmental Samples Using the Agilent 7500cx ICP-MS. Application. Author. Abstract. Introduction.

Total elemental analysis of food samples for routine and research laboratories using the Thermo Scientific icap RQ ICP-MS

Samples compliant with the WATER

Simple and Reliable Soil Analysis using the Agilent 7800 ICP-MS with ISIS 3

Optimizing Analytical Performance in ICP-OES Applications

Application of the Agilent 7900 ICP-MS with Method Automation function for the routine determination of trace metallic components in food CRMs

METHOD 6010A INDUCTIVELY COUPLED PLASMA-ATOMIC EMISSION SPECTROSCOPY

Analysis of trace elements in polymer samples to ensure compliance with WEEE-RoHS standards using the Thermo Scientific icap 7200 ICP-OES

Application note. Determination of exchangeable cations in soil extracts using the Agilent 4100 Microwave Plasma-Atomic Emission Spectrometer

Multi Analyte Custom Grade Solution. Calcium, Iron, Potassium,

Validation)of)a)horizontal)method) for)trace)elements)in)soil,) sludge)and)biowaste)

The Characterization of Nanoparticle Element Oxide Slurries Used in Chemical-Mechanical Planarization by Single Particle ICP-MS

BATTERY INDUSTRY STANDARD ANALYTICAL METHOD

UNIVERSITI SAINS MALAYSIA. Second Semester Examination Academic Session 2004/2005. March KAA 502 Atomic Spectroscopy.

Key Analytical Issues: Sample Preparation, Interferences and Variability. Tim Shelbourn, Eli Lilly and Company

DISCLAIMER: This method:

Determination of Nutrients. Determination of total phosphorus. Extraktion with aqua regia, reflux method. Introduction

ICP/MS Multi-Element Standards

Determination of ultratrace elements in photoresist solvents using the Thermo Scientific icap TQs ICP-MS

METHOD 3051 MICROWAVE ASSISTED ACID DIGESTION OF SEDIMENTS, SLUDGES, SOILS, AND OILS

DETERMINATION OF TRACE ELEMENTS IN DRINKING WATER BY AXIALLY VIEWED INDUCTIVELY COUPLED PLASMA - ATOMIC EMISSION SPECTROMETRY. Revision 4.

Rapid, simple, interference-free analysis of environmental samples using the XSERIES 2 ICP-MS with 3 rd generation CCT ED

Quantitative analysis of high purity metals using laser ablation coupled to an Agilent 7900 ICP-MS

PAR Method Method to 2.0 mg/l Pb TNTplus 850

Determinations by Atomic Absorption Spectroscopy and Inductively Coupled Plasma-Atomic Emission

Dimethylglyoxime Method Method to 6.0 mg/l Ni TNTplus 856

Applications of ICP-MS for Trace Elemental Analysis in the Hydrocarbon Processing Industry

METHOD 3010A ACID DIGESTION OF AQUEOUS SAMPLES AND EXTRACTS FOR TOTAL METALS FOR ANALYSIS BY FLAA OR ICP SPECTROSCOPY

Semiquantitative Screening of Pharmaceutical Antiviral Drugs using the Agilent 7500ce ICP-MS in Helium Collision Mode

PROCEDURES. Pharmacopeial Forum 2 Vol. 36(1) [Jan. Feb. 2009]

Unité d Agronomie, Centre de recherches INRA de Bordeaux, B.P. 81, Villenave d Ornon Cedex, France

Real World Analysis of Trace Metals in Drinking Water Using the Agilent 7500ce ICP-MS with Enhanced ORS Technology. Application. Authors.

TRACE ELEMENT ANALYSIS USING A BENCHTOP TXRF- SPECTROMETER

Microwave Assisted Acid Digestion of Sediments, Soils, and Tissues

1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:

Application. Determination of Trace Metal Impurities in Semiconductor-Grade Hydrofluoric Acid. Authors. Introduction. Abstract.

ICP-OES DETERMINATION OF IRON. Introduction:

Final Report. Characterisation of Sample Report. Job No 2016/11/12-34 AS No. 1234A. Client Example Contact Sample. Signed Date 2017.

CHEMISTRY DEPARTMENT

Basic Digestion Principles

Sludge, treated biowaste and soil Trace elements Method by inductively coupled plasma - Optical emission Spectrometry (ICP-OES)

Using cold vapor generation atomic absorption to determine mercury impurities in pharmaceutical products

Determination of residual carbon by inductively-coupled plasma optical emission spectrometry with axial and radial view configurations

Diquat 1,1 -ethylene-2,2 -bipyridium dibromide salt Paraquat 1,1 -dimethyl-4,4 -bipyridium dichloride salt Initial Preparation

Procedures for the determination of stable elements in construction materials from the nuclear reactors at Risø National Laboratory

Pharmacopeial Forum Vol. 36(1) [Jan. Feb. 2010] 1

CT Associates, Inc. Trace Metal Dynamic Extraction from Three Centrifugal Pumps in Hydrochloric Acid. Submitted to: Juergen Hahn Levitronix GmbH

Transcription:

ICP-OES Application Note Number 35 Rapid measurement of major, minor and trace levels in soils using the Varian 730-ES Vincent Calderon Varian, Inc. Introduction As part of the global strategy for sustainable farming, considerable emphasis has been placed on the need for fast, accurate and precise determination of elements in agricultural soil. As a result, simultaneous ICP-OES has become a widely used technique for reporting the health of soils in the agricultural industry. This work describes the preparation and analysis of certified reference soil materials using the Varian 730-ES simultaneous ICP-OES with CCD detection. The Varian 730-ES includes a switching valve system that improves the efficiency of sample introduction and washout, providing greater sample throughput and accuracy. A microwave-assisted acid digestion, based on recommendations given in US EPA method 3051A, was used to rapidly extract the elements from the soil samples. This method is not intended to accomplish total sample decomposition, and sample matrix compounds such as quartz, silicates, titanium dioxide, alumina and other oxides are not easily dissolved. For many environmental monitoring purposes, the concentrations of extractable elements are more important than total concentrations, as bound elements are not considered mobile in the environment 1. Instrumentation A Varian 730-ES (simultaneous ICP-OES with axially viewed plasma) was used for the analysis. The Varian 730-ES features a custom designed CCD detector, which provides true simultaneous measurement and full wavelength coverage from 167 to 785 nm. The patented CCD detector contains continuous angled arrays that are matched exactly to the two-dimensional image from the echelle optics. The thermally stabilized optical system contains no moving parts, ensuring excellent long-term stability. The Varian 730-ES also includes the productivity-enhancing Switching Valve System (SVS) that provides more efficient sample introduction and washout than traditional sample introduction systems. The SVS consists of a software-controlled, 4-port switching valve that instantaneously rinses the spray chamber following sample measurement while simultaneously presenting the next sample for measurement. A Mars % closed vessel, microwave digestion system from CEM was used to digest the solid samples. Solutions were presented to the spectrometer using the Varian SPS3, Sample Preparation System. Table 1 shows the operating parameters used in this work. Table 1. Operating parameters Condition Setting Power 1.2 kw Plasma gas flow 15 L/min Auxiliary gas flow 1.5 L/min Spray chamber type Glass cyclonic (single-pass) Torch Standard axial torch Nebulizer type Seaspray Nebulizer flow 0.7 L/min Pump tubing Sample: white-white (1.02 mm ID) Waste: blue-blue (1.65 mm ID) Buffer/Reference element: black-black (0.76 mm ID) Pump speed 15 rpm Total sample usage 1 ml Replicate read time 3 s Number of replicates 3 Sample delay time 20 s Switching valve delay 17 s Stabilization time 12 s Rinse time 1 s Fast pump On Background correction Fitted ICP-OES Application Note 35 1 of 5 www.varianinc.com

Preparation of Calibration Solutions Calibration solutions were prepared from Inorganic Ventures Inc. custom-grade multi-element solutions (VAR-CAL-1A, VAR-CAL-2A and VAR-MAJOR-1A) and from Spex CertiPrep single element solutions. These solutions contained the following elements: VAR-CAL-1A (1000 mg/l): Mo, Sb, Sn, and Ti VAR-CAL-2A (1000 mg/l): Ag, Al, As, Ba, Be, Cd, Co, Cr, Cu, Mn, Ni, Pb, Se, Th, Tl, U, V, and Zn VAR-MAJOR-1A (5000 ng/l): Ca, Fe, K, Mg, and Na Spex CertiPrep single element solutions: 1000 mg/l Al 1000 mg/l P 1000 mg/l Sr 1000 mg/l Ti Tables 2 and 3 list the selected elemental wavelengths and standard concentrations used to calibrate each element. Sensitivity, linear dynamic range and freedom from spectral interferences were taken into consideration during wavelength selection. Table 2. Calibration standards for the major and minor elements Element Wavelength (nm) 1 2 3 4 5 6 (mg/l) Al 396.125 2 10 20 100 200 500 Ca 317.933 1 10 20 100 200 500 Fe 234.350 1 10 20 100 200 500 Mg 285.213 1 10 20 100 200 - K 766.491 1 10 20 100 - - P 178.222 1 10 20 - - - Na 588.995 1 10 20 - - - Ti 336.122 1 10 20 - - - Table 3. Calibration standards for the minor and trace elements Element Wavelength (nm) 1 2 3 4 (µg/l) Cu 327.395 10 50 250 1000 10 000 100 000 Pb 220.353 10 50 250 1000 10 000 100 000 Mn 260.568 10 50 250 1000 10 000 100 000 Zn 206.200 10 50 250 1000 10 000 100 000 As 188.980 10 50 250 1000 10 000 - Ba 455.403 10 50 250 1000 10 000 - Cr 267.716 10 50 250 1000 10 000 - Sr 407.771 20 50 250 1000 10 000 - Ni 231.604 10 50 250 1000 - - V 292.401 10 50 250 1000 - - Cd 226.502 10 50 250 - - - Co 228.615 10 50 250 - - - Mo 202.032 10 50 250 - - - The calibration standard and blank solutions were prepared in > 18M Ω/cm 3 deionized water supplied from a Millipore system and stabilized with 5% v/v HNO 3 (Merck Tracepur ). 5 6 the third channel of the peristaltic pump. Yttrium was used for reference element (internal standard) correction and cesium was used as an ionization buffer to eliminate ionization affects that potentially exist with such matrix types 2-3. Sample Preparation A closed-vessel microwave-assisted acid digestion was used to extract the major, minor and trace elements from the soil samples following USEPA method 3051A guidelines. This method is designed to mimic extraction using conventional heating with nitric acid (HNO 3 ) and hydrochloric acid (HCl) and does not accomplish total decomposition of the sample. Therefore, the extracted analyte concentrations may not reflect the total content in the sample 4. Certified reference materials NIST SRM 2710 Montana Soil and NIST SRM 2709 San Joaquin Soil were used to validate the method. The soil samples were prepared by accurately weighing 0.25 g of sample into the microwave digestion vessels and adding 9 ml of 10M HNO 3 (Merck Tracepur ) and 3 ml of 10M HCl (AnalaR ). Following digestion, the solutions were cooled, then centrifuged for 30 minutes and transferred to 25.00 ml volumetric flasks. Each solution was diluted to volume with >18M Ω/cm 3 deionized water. Duplicate digestions were carried out. Table 4 shows the settings used for the temperature dependent, microwave assisted digestion. Table 4. Settings required for microwave digestion Stage Max. power % Power Ramp (min.) Pressure (PSI) Temp. ( C) Hold (min) 1 600 W 100 5:00 350 120 0:00 2 600 W 100 5:30 350 175 4:30 Stage 1 was added as a reflux step to remove particulate matter that adhered to the walls of the microwave vessel during sample addition. The moisture content of each reference material was determined as the certified values are based on dry weights. The samples were oven dried at 110 C for 2 hours then cooled in a desiccator for 4 hours. The data were adjusted accordingly. Table 5. Moisture content Measured moisture content Quoted moisture content range Montana soil (NIST SRM 2710) 2.3% 1.7% 2.3% San Joaquin soil (NIST SRM 2709) 2.4% 1.8% 2.5% Results and Discussion The measured concentrations of major, minor and trace elements in the respective soil reference materials are reported in Tables 6 10. Analyses were performed in triplicate and the error reported for each result represents the largest variation from the mean value. A solution containing 2 mg/l yttrium and 1% w/v CsNO 3 in 5% v/v Tracepur HNO 3 was introduced to the sample online via ICP-OES Application Note 35 2 of 5 www.varianinc.com

Table 6. Extractable major elements in soil Table 7. Extractable major and minor elements in soil Table 8. Extractable major and minor elements in soil Al (Wt%) Ca (Wt%) Fe (Wt%) Mg (Wt%) Certified median 1.8 0.41 2.7 0.57 Certified range 1.2-2.6 0.38-0.48 2.2-3.2 0.43-0.60 Digestion 1 2.07 ± 0.01 0.376 ± 0.003 2.50 ± 0.03 0.510 ± 0.016 Recovery 115 92 93 89 Digestion 2 2.05 ± 0.004 0.377 ± 0.001 2.50 ± 0.001 0.508 ± 0.005 Recovery 114 92 93 89 Certified median 2.6 1.5 3.0 1.4 Certified range 2.0-3.1 1.4-1.7 2.5-3.3 1.2-1.5 Digestion 1 2.00 ± 0.01 1.38 ± 0.01 2.63 ± 0.01 1.15 ± 0.01 Recovery 77 92 88 82 Digestion 2 2.54 ± 0.02 1.38 ± 0.01 2.74 ± 0.01 1.21 ± 0.02 Recovery 98 92 91 86 K (Wt%) P (Wt%) Na (Wt%) Ti (Wt%) Certified median 0.45 0.11 0.054 0.10 Certified range 0.37-0.50 0.106-0.11 0.049-0.062 0.092-0.11 Digestion 1 0.497 ± 0.003 0.0677 ± 0.0008 0.0613 ± 0.0003 0.122 ± 0.001 Recovery 110 62 114 122 Digestion 2 0.492 ± 0.001 0.0681 ± 0.0001 0.0612 ± 0.0002 0.120 ± 0.0003 Recovery 109 62 113 120 Certified median 0.32 0.07 0.068 0.038 Certified range 0.26-0.37 0.05-0.07 0.063-0.11 0.03-0.04 Digestion 1 0.347 ± 0.001 0.0442 ± 0.0003 0.0636 ± 0.0005 0.0234 ± 0.0001 Recovery 108 63 94 62 Digestion 2 0.408 ± 0.004 0.0444 ± 0.0004 0.0684 ± 0.0003 0.0545 ± 0.0006 Recovery 127 63 101 143 Zn (mg/kg) Mn (mg/kg) Cu (mg/kg) Ba (mg/kg) Sr (mg/kg) Certified median 5900 7700 2700 360 100 Certified range 5200-6900 6200-9000 2400-3400 300-400 94-110 Digestion 1 5815 ± 46 7054 ± 86 2426 ± 20 307 ± 4 90.9 ± 1.1 Recovery 99 92 90 85 91 Digestion 2 5897 ± 18 7064 ± 10 2436 ± 5 306 ± 1 90.6 ± 0.2 Recovery 100 92 90 85 91 Certified median 100 470 32 398 101 Certified range 87-120 360-600 26-40 392-400 100-112 Digestion 1 87.2 ± 0.3 483 ± 3 29.2 ± 0.3 367 ± 1 88.7 ± 0.5 Recovery 87 103 91 92 88 Digestion 2 84.2 ± 0.6 485 ± 6 29.3 ± 0.1 377 ± 3 91.4 ± 0.3 Recovery 84 103 92 95 90 ICP-OES Application Note 35 3 of 5 www.varianinc.com

Table 9. Extractable major, minor and trace elements in soil Pb (mg/kg) As (mg/kg) Cr (mg/kg) Ni (mg/kg) Co (mg/kg) Certified median 5100 590 19 10.1 8.2 Certified range 4300-7000 490-600 15-23 8.8-15 6.3-12 Digestion 1 4433 ± 22 514 ± 4 19.3 ± 0.1 10.4 ± 0.1 8.90 ± 0.06 Recovery 87 87 102 103 109 Digestion 2 4484 ± 29 518 ± 1 19.2 ± 0.1 10.3 ± 0.2 8.99 ± 0.05 Recovery 88 88 101 102 110 Certified median 13 <20 79 78 12 Certified range 12-18 - 60-115 65-90 10-15 Digestion 1 10.7 ± 0.1 15.3 ± 0.1 61.8 ± 0.2 67.7 ± 0.6 11.1 ± 0.1 Recovery 82-78 87 93 Digestion 2 11.0 ± 0.5 15.2 ± 0.6 72.5 ± 0.2 68.2 ± 0.3 11.5 ± 0.1 Recovery 85-92 87 96 Table 10. Extractable major, minor and trace elements in soil Cd (mg/kg) Mo (mg/kg) V (mg/kg) Certified median 20 20 43 Certified range 13-26 13-27 37-50 Digestion 1 16.4 ± 0.1 14.9 ± 0.1 48.7 ± 0.5 Recovery 82 75 113 Digestion 2 16.6 ± 0.1 14.9 ± 0.3 48.6 ± 0.1 Recovery 83 75 113 Certified median <1 <2 62 Certified range - - 51-70 Digestion 1 <0.2 1.51 ± 0.03 60.0 ± 0.2 Recovery - - 97 Digestion 2 <0.4 1.49 ± 0.05 74.2 ± 0.2 Recovery - - 120 Note: < value indicates an undetected element with the < value expressed as 10 times the standard deviation of background emission. Although a small amount of undissolved material was observed following microwave digestion, the overall measured concentrations of extractable major, minor and trace elements in the soil samples were in good agreement with the certified leach data. The major and minor elements Al, Fe, Mg, Na and K were within 15% of the respective certified median values and within the certified range for Montana soil (NIST SRM 2710). The same can be said for San Joaquin soil (NIST SRM 2709) although variation between the original (digestion 1) and duplicate values (digestion 2) were found to be greater with the measured value for magnesium in the original sample and potassium in the duplicate falling just outside the certified range. Good recovery was also achieved for calcium at 92% for both soil samples and duplicates, although the measured concentrations fell just outside the lower end of the certified range. With a measured recovery of 62 63% in both soil sample types, phosphorus did not appear to undergo complete extraction, although the reproducibility of the extraction for P was excellent. On the other hand, titanium produced mixed results suggesting incomplete extraction and inhomogeneity. The majority of the remaining extractable major, minor and trace elements (Zn, Mn, Cu, Ba, Sr, Pb, As, Cr, Ni, Cd, Co, Mo and V) fell within the certified range. Those that did not fall within the certified ranges were within 16% of the certified median value. ICP-OES Application Note 35 4 of 5 www.varianinc.com

Conclusion Two certified reference soil materials, containing variable levels of major, minor and trace elements were digested following US EPA Method 3051A and analysed on the Varian 730-ES Simultaneous ICP-OES. Agreement between the measured and certified values was generally very good. The switching valve, fast rinse accessory was also used allowing more efficient introduction and washout of the sample from the sample introduction system. The determination of 21 elements in a sample took less than 65 seconds and required approximately 1 ml of solution, making the Varian 730-ES an excellent analytical tool for fast and efficient analysis of soils. References Ryan, A. Direct analysis of milk powder on the Liberty Series II ICP-AES with the axially-viewed plasma. ICP Instruments at work, 1997, ICP-21. US EPA Method 3051A Microwave Assisted Acid Digestion of Sediments, Sludges, Soils and Oils. Revision 1, 1998. These data represent typical results. For further information, contact your local Varian Sales Office. Varian, Inc. www.varianinc.com North America: 800.926.3000 925.939.2400 Europe: The Netherlands: 31.118.67.1000 Asia Pacific: Australia: 613.9560.7133 Latin America: Brazil: 55.11.3845.0444