CONNECTION DESIGN. Connections must be designed at the strength limit state

Similar documents
MODULE F: SIMPLE CONNECTIONS

Timber and Steel Design. Lecture 11. Bolted Connections

Tension Members. ENCE 455 Design of Steel Structures. II. Tension Members. Introduction. Introduction (cont.)

Application nr. 7 (Connections) Strength of bolted connections to EN (Eurocode 3, Part 1.8)

Slip Critical Bolted Connections A Reliability Analysis for Design at the Ultimate Limit State

[5] Stress and Strain

TORSION INCLUDING WARPING OF OPEN SECTIONS (I, C, Z, T AND L SHAPES)

Sabah Shawkat Cabinet of Structural Engineering Walls carrying vertical loads should be designed as columns. Basically walls are designed in

FHWA Bridge Design Guidance No. 1 Revision Date: July 21, Load Rating Evaluation of Gusset Plates in Truss Bridges

Presented by: Civil Engineering Academy

Hilti North America Installation Technical Manual Technical Data MI System Version

Unfinished Bolt ordinary, common, rough or black bolts High strength Bolt friction type bolts

db = 23.7 in B C D 96 k bf = 8.97 in tf = in k = 1.09 in 13 Fy = 50 ksi Fu = 65 ksi Member A-B, Interior column: A E

Project data Project name Project number Author Description Date 26/04/2017 Design code AISC dome anchor. Material.

Hilti North America Installation Technical Manual Technical Data MI System Version

Karbala University College of Engineering Department of Civil Eng. Lecturer: Dr. Jawad T. Abodi

STEEL. General Information

Example 4: Design of a Rigid Column Bracket (Bolted)

Stress Transformation Equations: u = +135 (Fig. a) s x = 80 MPa s y = 0 t xy = 45 MPa. we obtain, cos u + t xy sin 2u. s x = s x + s y.

D e s i g n o f R i v e t e d J o i n t s, C o t t e r & K n u c k l e J o i n t s

MECHANICS OF MATERIALS. Prepared by Engr. John Paul Timola

Structural Steelwork Eurocodes Development of A Trans-national Approach

SHEAR LAG IN SLOTTED-END HSS WELDED CONNECTIONS

Job No. Sheet 1 of 6 Rev B. Made by IR Date Oct Checked by FH/NB Date Oct Revised by MEB Date April 2006

Appendix J. Example of Proposed Changes

Failure in Flexure. Introduction to Steel Design, Tensile Steel Members Modes of Failure & Effective Areas

CH. 5 TRUSSES BASIC PRINCIPLES TRUSS ANALYSIS. Typical depth-to-span ratios range from 1:10 to 1:20. First: determine loads in various members

An investigation of the block shear strength of coped beams with a welded. clip angles connection Part I: Experimental study

Design of Shear Tab Connections for Gravity and Seismic Loads

S E C T I O N 1 2 P R O D U C T S E L E C T I O N G U I D E - H E L I C A L S C R E W P I L E F O U N D A T I O N S

SECTION 7 DESIGN OF COMPRESSION MEMBERS

Mechanics of Materials Primer

THEORETICAL DESIGN OF A NAILED OR BOLTED JOINT UNDER LATERAL LOAD 1. Summary

Fundamentals of Structural Design Part of Steel Structures

Structural Steelwork Eurocodes Development of a Trans-National Approach

This procedure covers the determination of the moment of inertia about the neutral axis.

Investigation of basic elements loading and tension of heavy hydraulic presses for metallurgical production

Experimental investigation on monotonic performance of steel curved knee braces for weld-free beam-to-column connections

The subject of this paper is the development of a design

Example 1 - Single Headed Anchor in Tension Away from Edges BORRADOR. Calculations and Discussion

Appendix K Design Examples

twenty steel construction: columns & tension members ARCHITECTURAL STRUCTURES: FORM, BEHAVIOR, AND DESIGN DR. ANNE NICHOLS FALL 2013 lecture

MODULE C: COMPRESSION MEMBERS

Chapter Objectives. Design a beam to resist both bendingand shear loads

PLATE GIRDERS II. Load. Web plate Welds A Longitudinal elevation. Fig. 1 A typical Plate Girder

[8] Bending and Shear Loading of Beams

Special edition paper

ES230 STRENGTH OF MATERIALS

Curved Steel I-girder Bridge LFD Guide Specifications (with 2003 Edition) C. C. Fu, Ph.D., P.E. The BEST Center University of Maryland October 2003

QUESTION BANK SEMESTER: III SUBJECT NAME: MECHANICS OF SOLIDS

SIMPLE MODEL FOR PRYING FORCES IN T-HANGER CONNECTIONS WITH SNUG TIGHTENED BOLTS

Final Exam - Spring

Metal Structures Lecture XIII Steel trusses

my!wind Ltd 5 kw wind turbine Static Stability Specification

Chapter 8: Bending and Shear Stresses in Beams

Accordingly, the nominal section strength [resistance] for initiation of yielding is calculated by using Equation C-C3.1.

RESILIENT INFRASTRUCTURE June 1 4, 2016

ALUMINUM STRUCTURAL PLATE HEADWALLS AASHTO LRFD BASIS OF DESIGN

Table of Contents. Preface...xvii. Part 1. Level

Solid Mechanics Chapter 1: Tension, Compression and Shear

Equivalent T-stubs (Component Method) as per DIN EN

DESIGN OF BEAM-COLUMNS - II

MECE 3321 MECHANICS OF SOLIDS CHAPTER 3

NICE-PACK ALCOHOL PREP ROOM PLATFORM CALCULATIONS

COLUMN BASE WEAK AXIS ALIGNED ASYMMETRIC FRICTION CONNECTION CYCLIC PERFORMANCE

Design of Beams (Unit - 8)

Hilti HSV-F Stud anchor

my!wind Ltd 5 kw wind turbine Static Stability Specification

Structural Steelwork Eurocodes Development of A Trans-national Approach

MEMS Project 2 Assignment. Design of a Shaft to Transmit Torque Between Two Pulleys

ME 202 STRENGTH OF MATERIALS SPRING 2014 HOMEWORK 4 SOLUTIONS

TECHNICAL CORRECTION July Process Industry Practices Structural. PIP STE03360 Heat Exchanger and Horizontal Vessel Foundation Design Guide

Failure from static loading

OUTLINE DESIGN OF COLUMN BASE PLATES AND STEEL ANCHORAGE TO CONCRETE 12/21/ Introduction 2. Base plates. 3. Anchor Rods

CHAPTER II EXPERIMENTAL INVESTIGATION

QUESTION BANK DEPARTMENT: CIVIL SEMESTER: III SUBJECT CODE: CE2201 SUBJECT NAME: MECHANICS OF SOLIDS UNIT 1- STRESS AND STRAIN PART A

Structural Steelwork Eurocodes Development of A Trans-national Approach

NAME: Given Formulae: Law of Cosines: Law of Sines:

the Steel Construction Manual

Karbala University College of Engineering Department of Civil Eng. Lecturer: Dr. Jawad T. Abodi

MECHANICS OF MATERIALS

db = 23.7 in B C D 96 k bf = 8.97 in tf = in k = 1.09 in 13 Fy = 50 ksi Fu = 65 ksi Member A-B, Interior column: A E

Anchor Bolt Design (Per ACI and "Design of Reinforcement in Concrete Pedestals" CSA Today, Vol III, No. 12)

Design of Steel Structures Prof. Damodar Maity Department of Civil Engineering Indian Institute of Technology, Guwahati

NORMAL STRESS. The simplest form of stress is normal stress/direct stress, which is the stress perpendicular to the surface on which it acts.

Structural Analysis I Chapter 4 - Torsion TORSION

General Comparison between AISC LRFD and ASD

PIXEL DUMMY SUPPORT TUBE LIFTING DEVICE ENGINEERING CALCULATION

CHAPTER 4. Stresses in Beams

: APPLIED MECHANICS & STRENGTH OF MATERIALS COURSE CODE : 4021 COURSE CATEGORY : A PERIODS/ WEEK : 5 PERIODS/ SEMESTER : 75 CREDIT : 5 TIME SCHEDULE

1. ARRANGEMENT. a. Frame A1-P3. L 1 = 20 m H = 5.23 m L 2 = 20 m H 1 = 8.29 m L 3 = 20 m H 2 = 8.29 m H 3 = 8.39 m. b. Frame P3-P6

FE-Analysis of Stringer-to-floor-beam Connections in Riveted Railway Bridges

Roadway Grade = m, amsl HWM = Roadway grade dictates elevation of superstructure and not minimum free board requirement.

PURE BENDING. If a simply supported beam carries two point loads of 10 kn as shown in the following figure, pure bending occurs at segment BC.

BPSC Main Exam 2019 ASSISTANT ENGINEER. Test 11. CIVIL ENGINEERING Subjective Paper-I. Detailed Solutions. Detailed Solutions

Low Cycle Fatigue Behavior of a Reduced End Plate Moment Connection (T-Stub)

Science 7 Unit B: Structures and Forces. Topic 4. Forces, Loads, & Stresses. pp WORKBOOK. Name:

Four-Point Bending and Direct Tension Testing of Twelve Inch TR-XTREME Pipe Joint

APPENDIX G I-BEAM SUMMARIES 0.6-IN. STRAND G-1

Lecture-03 Design of Reinforced Concrete Members for Flexure and Axial Loads

Transcription:

CONNECTION DESIGN Connections must be designed at the strength limit state Average of the factored force effect at the connection and the force effect in the member at the same point At least 75% of the force effect in the member End connections for diaphragms, cross-frames, lateral bracing for straight flexural members - designed for factored member loads Connections should be symmetrical about member axis At least two bolts or equivalent weld per connection Members connected so that their gravity axes intersect at a point Eccentric connections should be avoided End connections for floorbeams and girders Two angles with thickness > 0.375 in. Made with high strength bolts If welded account for bending moment in design

BOLTED CONNECTIONS Slip-critical and bearing type bolted connections. Connections should be designed to be slip-critical where: stress reversal, heavy impact loads, severe vibration joint slippage would be detrimental to the serviceability of the structure Joints that must be designed to be slip-critical include Joints subject to fatigue loading or significant load reversal. Joints with oversized holes or slotted holes Joints where welds and bolts sharing in transmitting load Joints in axial tension or combined axial tension and shear Bearing-type bolted connections can be designed for joints subjected to compression or joints for bracing members

SLIP-CRITICAL BOLTED CONNECTION Slip-critical bolted connections can fail in two ways: (a) slip at the connection; (b) bearing failure of the connection Slip-critical connection must be designed to: (a) resist slip at load Service II; and (b) resist bearing / shear at strength limit states

SLIP-CRITICAL BOLTED CONNECTION Slip-critical bolted connections can be installed with such a degree of tightness large tensile forces in the bolt clamp the connected plates together Applied Shear force resisted by friction P P Tightened N =T b P N =T b N =T b F=µN T b F=µN N =T b T b P N = T b N = T b

SLIP-CRITICAL BOLTED CONNECTION Slip-critical connections can resist the shear force using friction. If the applied shear force is less than the friction that develops between the two surfaces, then no slip will occur between them Nominal slip resistance of a bolt in a slip-critical connection R n = K h K s N s P t Where, P t = minimum required bolt tension specified in Table 1 K h = hole factor specified in Table 1 K s = surface condition factor specified in Table 3

SLIP-CRITICAL BOLTED CONNECTION Values of K h For standard holes 1.0 Values of P t Required Tension (kips) A325 A490 5/8 19 24 3/4 28 35 7/8 39 49 1 51 64 Bolt diameter (in.) 1-1/8 56 80 1-1/4 71 102 1-3/8 85 121 1-1/2 103 148 For oversize and short-slotted holes 0.85 For long slotted holes with the slot Perpendicular to the force direction For long-slotted holes with the slot Parallel to the force direction Values of K s For Class A surface conditions 0.33 For Class B surface conditions 0.50 0.70 0.60 For Class C surface conditions 0.33 Faying surfaces Unpainted clean mill scale, and blast-cleaned surfaces with Class A coating Unpainted blast-cleaned surfaces with Class B coating Hot-dip galvanized surfaces roughened by wire brushing Class C

SLIP-CRITICAL CONNECTION Connection subjected to tensile force (T u ), which reduces clamping Nominal slip resistance should be reduced by (1- T u /P t ) Slip is not a catastrophic failure limit-state because slip-critical bolted connections behave as bearing type connections after slip. Slip-critical bolted connections are further designed as bearing-type bolted connection for the applicable factored strength limit state.

BEARING CONNECTION In a bearing-type connection, bolts are subjected to shear and the connecting / connected plates are subjected to bearing stresses : T T T Bearing stresses in plate Bolt in shear Bearing stresses in plate T

BEARING CONNECTION Bearing type connection can fail in several failure modes a) Shear failure of the bolts b) Excessive bearing deformation at the bolt holes in the connected parts c) Edge tearing or fracture of the connected plate d) Tearing or fracture of the connected plate between two bolt holes e) Failure of member being connected due to fracture or block shear or...

BEARING CONNECTION Nominal shear resistance of a bolt Threads excluded: R n = 0.48 A b F ub N s Threads included: R n = 0.38 A b F ub N s Where, A b = area of the bolt corresponding to the nominal diameter F ub = 120 ksi for A325 bolts with diameters 0.5 through 1.0 in. F ub = 105 ksi for A325 bolts with diameters 1.125 through 1.5 in. F ub = 150 ksi for A490 bolts. N s = number of shear planes Resistance factor for bolts in shear = φ s = 0.80 Equations above - valid for joints with length < less than 50.0 in. If the length is greater than 50 in., then the values from the equations have to be multiplied by 0.8

BEARING CONNECTION Effective bearing area of a bolt = the bolt diameter multiplied by the thickness of the connected material on which it bears Bearing resistance for standard, oversize, or short-slotted holes in any direction, and long-slotted holes parallel to the bearing force: For bolts spaced with clear distance between holes greater than or equal to 3.0 d and for bolts with a clear end distance greater than or equal to 2.0 d R n = 2.4 d t F u For bolts spaced with clear distance between holes less than 3.0 d and for bolts with clear end distances less than 2.0 d R n = 1.2 L c t F u Where, d = nominal bolt diameter L c = clear distance between holes or between the hole and the end of the member in the direction of applied bearing force F u = tensile strength of the connected material The resistance factor φ bb for material in bearing due to bolts = 0.80

BEARING CONNECTION SPACING REQUIREMENTS Minimum spacing between centers of bolts in standard holes shall not be less than three times the diameter of the bolt For sealing against penetration of moisture in joints, the spacing on a single line adjacent to the free edge shall satisfy s (4.0 + 4.0 t) 7.0 Minimum edge distances Bolt diameter (in.) Sheared edge 5/8 1-1/8 7/8 3/4 1-1/4 1 7/8 1-1/2 1-1/8 1 1-3/4 1-1/4 1-1/8 2 1-1/2 1-1/4 2-1/4 1-5/8 1-3/8 2-3/8 1-3/4 Rolled or Gas Cut edge

BOLTED CONNECTION Example 1 Design a slip-critical splice for a tension member. For the Service II load combination, the member is subjected to a tension load of 200 kips. For the strength limit state, the member is subjected to a maximum tension load of 300 kips. The tension member is a W8 x 28 section made from M270-Gr. 50 steel. Use A325 bolts to design the slip-critical splice. Step I. Service and factored loads Service Load = 200 kips. Factored design load = 300 kips Tension member is W8 x 28 section made from M270 Gr.50. The tension splice must be slip critical (i.e., it must not slip) at service loads.

BOLTED CONNECTION Step II. Slip-critical splice connection Slip resistance of one fully-tensioned slip-critical bolt = R n = K h K s N s P t φ = 1.0 for slip-critical resistance evaluation Assume bolt diameter = d = ¾ in. Therefore P t = 28 kips from Table 1 Assume standard holes. Therefore K h = 1.0 Assume Class A surface condition. Therefore K s = 0.33 Therefore, φr n = 1.0 x 0.33 x 1 x 28 = 9.24 kips Therefore, number of ¾ in. diameter bolts required for splice to be slipcritical at service loads = 200 / 9.24 = 21.64. Therefore, number of bolts required 22

BOLTED CONNECTION Step III: Layout of flange-plate splice connection To be symmetric about centerline, need the number of bolts = multiple of 8. Therefore, choose 24 fully tensioned 3/4 in. A325 bolts with layout above. Slip-critical strength of the connection = 24 x 9.24 kips = 221.7 kips Minimum edge distance (L e ) = 1 in. from Table 4. Design edge distance L e = 1.25 in. Minimum spacing = s = 3 x bolt diameter = 3 x ¾ = 2.25 in. Design spacing = 2.5 in.

BOLTED CONNECTION Step IV: Connection strength at factored loads The connection should be designed as a normal shear/bearing connection beyond this point for the factored load of 300 kips Shear strength of high strength bolt = φ R n = 0.80 x 0.38 x A b x F ub N s Equation given earlier for threads included in shear plane. A b = 3.14 x 0.75 2 / 4 = 0.442 in 2 F ub = 120 ksi for A325 bolts with d < 1-1/8 in. N s = 1 Therefore, φr n = 16.1 kips The shear strength of 24 bolts = 16.1 kips/bolt x 24 = 386.9 kips

BOLTED CONNECTION Bearing strength of 3/4 in. bolts at edge holes (L e = 1.25 in.) φ bb R n = 0.80 x 1.2 L c t F u Because the clear edge distance = 1.25 (3/4 + 1/16)/2 = 0.84375 in. < 2 d φ bb R n = 0.80 x 1.2 x 0.84375 x 65 kips x t = 52.65 kips / in. thickness Bearing strength of of 3/4 in. bolts at non-edge holes (s = 2.5) φ bb R n = 0.80 x 2.4 d t F u Because the clear distance between holes = 2.5 (3/4 + 1/16) = 1.6875 in. > 2d φ bb R n = 0.80 x 2.4 x 0.75 x 65 kips x t = 93.6 kips / in. thickness Bearing strength of bolt holes in flanges of wide flange section W8 x 28 (t = 0.465 in.) 8 x 52.65 x 0.465 +16 x 93.6 x 0.465 = 892 kips

CONNECTION STRENGTH Connection Strength Slip-critical strength = 221.7 kips Shear strength of bolts = 386.9 kips Bearing strength (plate) = 892 kips Connection strength (φr n ) > applied factored loads (γq). Therefore ok