Product description Spotlights Downlights High-flux LED module Narrow colour temperature tolerance band Lifetime up to 5, hours Compact design Excellent thermal management 1 NTC for temperature control High-power LED in chip-on-board technololgy Beam characteristic: 14 Uniform distribution of light Fixing holes for M3 screws Connection: Cable 3 mm Built-in LED module Cooling required Technical data Beam characteristic 14 Ambient temperature ta -3... +55 C Typ. tc point 65 C Weight.15 kg Risk group (EN 62471:28) È Standards, page 3 Colour temperatures and tolerances, page 6, 7 Umodule SPOT P32-3 umodule SPOT NTC NTC LED + LED 39,5 35,5 8,5 4,5 5 6 2 1 3 4 8,5 46,5 23,5 38,5 Ø3,2 1,65 NTC tc Ø23 1 Ø28,5 2 44 2, typ. 1 Minimal reflector diameter 2 Maximum reflector diameter Ordering data Colour temperature Type Article number 3, K LED P32-3 3K 47x44 8961415 3,5 K LED P32-3 35K 47x44 8961416 4, K LED P32-3 4K 47x44 8961417 5, K LED P32-3 5K 47x44 8961418 Packaging: 2 pieces/packaging, 36 pieces/carton Specific technical data Type Photometric Typ. luminous flux Typ. luminous flux Typ. Efficacy Colour rendering index code at 7 ma 234 at 1,5 ma 234 Typ. forward voltage module CRI LED P32-3 3K 47x44 83/4x9 1,34 lm 1,85 lm 28.8 V 2.2 W 67 lm/w > 8 LED P32-3 35K 47x44 835/4x9 1,34 lm 1,85 lm 28.8 V 2.2 W 67 lm/w > 8 LED P32-3 4K 47x44 84/4x9 1,48 lm 2,5 lm 28.8 V 2.2 W 74 lm/w > 8 LED P32-3 5K 47x44 75/4x9 1,68 lm 2,25 lm 28.8 V 2.2 W 84 lm/w > 7 All values for ta = 25 C, tc = 65 C. 1 If the maximum temperature limits are exceeded, the life of the module will be greatly reduced or the module may be damaged. The temperature of the umodule SPOT at the tc point in the thermally stable state by mean of a temperature sensor or temperature-sensitive sticker as per EN 6598-1. For the precise position of the tc point see the drawing above. 2 At tc = 65 C. 3 Tolerance range for optical and electrical data: ±15 %. 4 Max. permissible surge current: 3 A, duration max. 1 µs. Data sheet 7/12-LED56-3 www.tridonic.com 1
Converter / controls matrix Umodule SPOT P32-3 Type LCAI 3 W 7 ma one4all Converter REMOTE LCI LCI 3 W 7 ma LCI 5 W 15mA T2 LCAI 5 W 15 ma T2 LCI 5 W 15 ma R1 Controls IN-BUILT LCAI 5 W 15 ma R1 C7 dim Article number 864589 24166314 86459218 86459247 86453216 86459245 86458945 Type Min. Max. Min. Max. Min. Max. Min. Max. Min. Max. Min. Max. Min. Max. Umodule SPOT P32-3 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Wiring Cable: AWG24; length 3 mm pin 1 2 5 6 function + - NTC NTC colour red black grey grey Product description Housing for LED module Diameter: 5 mm ACCES- SORIES TALEXXaccessory Cover Spot Ordering data Typ Article number P 32-3 EM LED cover white D5 LES 23 mm 88167489 Packaging: 2 pieces/packaging, 4 pieces/carton Data sheet 7/12-LED56-3 www.tridonic.com 2
Standards EN 6231 EN 62471 Photometric code Key for photometric code, e. g. 83 / 559 1 st digit 2 nd + 3 rd digit 4 th digit 5 th digit 6 th digit Lumen maintanance after 25% Code CRI McAdams after of the lifetime (max.6h) Colour temperature in McAdams 25% of the Code Remaining lumen 7 67 76 Kelvin x 1 initial lifetime 7 7 % 8 77 86 (max.6h) 8 8 % 9 87 9 9 9 % Thermal design and heat sink The rated life of u products depends to a large extent on the temperature. If the permissible temperature limits are exceeded, the life of the umodule SPOT will be greatly reduced or the umodule SPOT may be destroyed. Therefore the umodule SPOT P32-3 needs to be mounted onto a heat sink. Tridonic s excellent thermal design for the umodule SPOT products provides the lowest thermal resistance and therefore allowing new compact designs without sacrificing quality, safety and life time. tc point, ambient temperature and lifetime The temperature at tc reference point is crucial for the light output and life time of a u product. For umodule SPOT P32-3 a tc temperature of 65 C has to be complied in order to achieve an optimum between heat sink requirements, light output and life time. Compliance with the maximum permissible reference temperature at the tc point must be checked under operating conditions in a thermally stable state. The maximum value must be determined under worst-case conditions for the relevant application. Mounting instruction umodule SPOT from Tridonic which have to be installed on a heat sink have to be connected with heat-conducting paste or heat conducting adhesive film and fixed with M3 screws with plastic washer. The fixing/cooling surface must be cleaned before installing the u modules to remove all dirt, dust and grease. None of the components of the umodule SPOT (substrate, LED, electronic components etc.) may be exposed to tensile or compressive stresses. EOS/ESD safety guidelines The device / module contains components that are sensitive to electrostatic discharge and may only be installed in the factory and on site if appropriate EOS/ESD protection measures have been taken. No special measures need be taken for devices/modules with enclosed casings (contact with the pc board not possible), just normal installation practice. Please note the requirements set out in the document EOS / ESD guidelines (Guideline_EOS_ESD.pdf) at: http://www.tridonic.com/com/en/technical-docs.asp Temperature control An NTC resistor is on the board of the umodule SPOT P32-3 to control the tc temperature during the operation. Exact position see drawing on page 1. The details of the 22 kω NTC (order number B57431V2223J62) you can find in the data sheet of the manufacturer AVX (Nr. NB12QØØ224). Resistance [kω] Typical heat sink surface Umodule SPOT P32-3, 7 ma ta tc Rth, hs-a 25 C 65 C 2.9 K/W 3 C 65 C 1.81 K/W 4 C 65 C 1.24 K/W 5 C 65 C.68 K/W Umodule SPOT P32-3, 1,5 ma ta tc Rth, hs-a 25 C 55 C.96 K/W 3 C 55 C.77 K/W 4 C 55 C.4 K/W Notes The actual cooling surface can differ because of the material, the structural shape, outside influences and the installation situation. A thermal connection between umodule SPOT and heat sink with heat-conducting paste or heat conducting adhesive film is absolutely necessary. Thermal behaviour storage temperature -3 85 C operating temperature -3 55 C tc max. (at typ. current) 85 C If [ma] 24 22 2 18 16 14 12 1 8 6 4 2 25 3 35 4 45 5 55 6 65 7 75 Temperature [ C] 16 14 12 1 8 6 4 2 1 2 3 4 5 6 7 8 9 1 Tc [ C] 8 85 Data sheet 7/12-LED56-3 www.tridonic.com 3
Matrix temperature Lumen maintenance f(soldering time) for the modules Temperature Max. time Max. time without heat sink with optimized heat sink 33 C 15 s 34 C 12 s 35 C 1 s 36 C 5 s 15 s 37 C 3 s 12 s 38 C 2 s 1 s 39 C 1 s 5 s The values apply for soldering without heat sink. To reduce the duration of soldering it is recommended to pre-heat the module at ta max., e.g. on a plate. Electrical supply/choice of converter umodule SPOT from Tridonic are not protected against overvoltages, overcurrents, overloads or short-circuit currents. Safe and reliable operation can only be guaranteed in conjunction with a converter which complies with the relevant standards. The use of u converters from Tridonic in combination with umodule SPOT guarantees the necessary protection for safe and reliable operation. If a converter other than Tridonic uconverter is used, it must provide the following protection: Short-circuit protection Overload protection Overtemperature protection umodule SPOT P32-3 must be supplied by a constant current converter. Operation with a constant voltage converter will lead to an irreversible damage of the module. Wrong polarity can damage the umodule SPOT P32-3. tc temperature in C luminous flux in % operating time in h 8 6, 25 7 81, 5 132, 8 44, 45 7 64, 5 11, 8 32, 65 7 5, 5 91, 8 25, 75 7 41, 5 81, Data sheet 7/12-LED56-3 www.tridonic.com 4
Relative forward voltage and relative luminous flux rel. voltage [a. u.] rel. luminous flux [a. u.],4,2 2 3 4 5 6 7 8 current [ma] Relative luminous flux at tc = 65 C The diagrams based on statistic values. The real values can be different. Optical characteristics Umodule SPOT P32-3 9 1 11 The optical design of the umodule SPOT product line ensures optimum homogenity for the light distribution. relative intensity Iv/Iv,max 1,1 1,5 1,,95,9 2 3 4 5 6 7 8 current [ma] Relative forward voltage at tc = 65 C 1,4 1,2 1,,8,6 Umodule SPOT P32-3 14 : Light distribution 1 8 6-6 4 2-5 -4-1 -2-3 1 9 1 11 2 3 4 5 6 7 8 rel. voltage [a.u.] rel. luminous flux [a.u.] 1,5 1,4 1,3 1,2 1,1 1,99,98,97 2 3 4 5 6 7 Tc [ C] 1,14 1,12 1,1 1,8 1,6 1,4 1,2 1,98,96,94 8 85,92 2 3 4 5 6 7 8 85 Tc [ C] -9-1 -8-6 -4-2 2 4 6 8 1 9 Data sheet 7/12-LED56-3 www.tridonic.com 5
Coordinates and tolerances according to CIE 1964 The specified colour coordinates are measured by a current impulse of 7 ma and a duration of 1 ms. The ambient temperature of the measurement is ta = 25 C. The measurement tolerance of the colour coordinates are ±.1. 3, K x y Centre,446,399,42,415,41,45,4,395,39,385,38,41,45,4,395,39,385,38,375,37,425 3,5 K,395,43,4,435,45,44,41,445 x y Centre,416,39,415,45,42,455,425,46,43,465,435 1 8 6 4 2 1 38 42 46 5 54 58 62 66 7 74 78 8 6 4 2 38 42 46 5 54 58 62 66 7 74 78 Data sheet 7/12-LED56-3 www.tridonic.com 6
4, K x y Centre,386,378.4.395.39.385.38.375.37.365.36 5, K x y Centre,353,359,38,375,37,365,36,355,35,345,34.365,335.37,34.375,345.38,35.385,355.39,36.395,365.4,37.45,375 1 8 6 4 2 1 38 42 46 5 54 58 62 66 7 74 78 8 6 4 2 38 42 46 5 54 58 62 66 7 74 78 Data sheet 7/12-LED56-3 www.tridonic.com 7