Force Measurement with a Piezoelectric Cantilever in a Scanning Force Microscope

Similar documents
Dopant Concentration Measurements by Scanning Force Microscopy

Force-distance studies with piezoelectric tuning forks below 4.2K

Measurement of hardness, surface potential, and charge distribution with dynamic contact mode electrostatic force microscope

Chapter 2 Correlation Force Spectroscopy

Lecture 4 Scanning Probe Microscopy (SPM)

Scanning Probe Microscopy (SPM)

COURSE OUTLINE. Introduction Signals and Noise Filtering Sensors: Piezoelectric Force Sensors. Sensors, Signals and Noise 1

MAS.836 PROBLEM SET THREE

Module 26: Atomic Force Microscopy. Lecture 40: Atomic Force Microscopy 3: Additional Modes of AFM

STM: Scanning Tunneling Microscope

Finite Element Analysis of Piezoelectric Cantilever

Introduction to Nanomechanics: Magnetic resonance imaging with nanomechanics

Piezoelectric Resonators ME 2082

Application of electrostatic force microscopy in nanosystem diagnostics

developed piezoelectric self-excitation and selfdetection mechanism in PZT microcantilevers for dynamic scanning force microscopy in liquid

Design and Analysis of Various Microcantilever Shapes for MEMS Based Sensing

Integrating MEMS Electro-Static Driven Micro-Probe and Laser Doppler Vibrometer for Non-Contact Vibration Mode SPM System Design

Basic Laboratory. Materials Science and Engineering. Atomic Force Microscopy (AFM)

Piezoelectric Actuator for Micro Robot Used in Nanosatellite

7.Piezoelectric, Accelerometer and Laser Sensors

CNPEM Laboratório de Ciência de Superfícies

Instrumentation and Operation

Introduction to Scanning Probe Microscopy

Program Operacyjny Kapitał Ludzki SCANNING PROBE TECHNIQUES - INTRODUCTION

MCE603: Interfacing and Control of Mechatronic Systems

Lecture 19. Measurement of Solid-Mechanical Quantities (Chapter 8) Measuring Strain Measuring Displacement Measuring Linear Velocity

Mechatronics II Laboratory EXPERIMENT #1: FORCE AND TORQUE SENSORS DC Motor Characteristics Dynamometer, Part I

Lecture 20. Measuring Pressure and Temperature (Chapter 9) Measuring Pressure Measuring Temperature MECH 373. Instrumentation and Measurements

SCANNING-PROBE TECHNIQUES OR APPARATUS; APPLICATIONS OF SCANNING-PROBE TECHNIQUES, e.g. SCANNING PROBE MICROSCOPY [SPM]

Atomic and molecular interactions. Scanning probe microscopy.

Scanning Tunneling Microscopy

INTRODUCTION TO PIEZO TRANSDUCERS

EE C247B / ME C218 INTRODUCTION TO MEMS DESIGN SPRING 2014 C. Nguyen PROBLEM SET #4

SURFACE-DISPLACEMENT IMAGING USING OPTICAL BEAM DEFLECTION. S.E. McBride* and G.C. Wetsel, Jr.* Southern Methodist University Dallas, Texas 75275

Lecture Note October 1, 2009 Nanostructure characterization techniques

Scanning Probe Microscopy. Amanda MacMillan, Emmy Gebremichael, & John Shamblin Chem 243: Instrumental Analysis Dr. Robert Corn March 10, 2010

Characterization of MEMS Devices

Supplementary Materials. Mechanics and Chemistry: Single Molecule Bond Rupture Forces Correlate with

Vibration Studying of AFM Piezoelectric Microcantilever Subjected to Tip-Nanoparticle Interaction

Scanning Force Microscopy

Dynamic behavior of a piezowalker, inertial and frictional configurations

A simple method to characterize the electrical and mechanical properties of micro-fibers

Optimization of Force Sensitivity in Q-Controlled Amplitude-Modulation Atomic Force Microscopy

Electrostatic Force Microscopy (EFM)

FEM-SIMULATIONS OF VIBRATIONS AND RESONANCES OF STIFF AFM CANTILEVERS

Introduction to Scanning Tunneling Microscopy

INTRODUCTION TO SCA\ \I\G TUNNELING MICROSCOPY

Towards nano-mri in mesoscopic transport systems

BDS2016 Tutorials: Local Dielectric Spectroscopy by Scanning Probes

10 Measurement of Acceleration, Vibration and Shock Transducers

Imaging Methods: Scanning Force Microscopy (SFM / AFM)

CHAPTER 4 DESIGN AND ANALYSIS OF CANTILEVER BEAM ELECTROSTATIC ACTUATORS

Effect of AFM Cantilever Geometry on the DPL Nanomachining process

Simple and Low Cost Polarimeter System

Magnetic dissipation force microscopy studies of magnetic materials invited

Design and Simulation of Comb Drive Capacitive Accelerometer by Using MEMS Intellisuite Design Tool

Nano and micro Hall-effect sensors for room-temperature scanning hall probe microscopy

Contents. What is AFM? History Basic principles and devices Operating modes Application areas Advantages and disadvantages

Mechatronics II Laboratory EXPERIMENT #1 MOTOR CHARACTERISTICS FORCE/TORQUE SENSORS AND DYNAMOMETER PART 1

Point mass approximation. Rigid beam mechanics. spring constant k N effective mass m e. Simple Harmonic Motion.. m e z = - k N z

Optimal Design and Evaluation of Cantilever Probe for Multifrequency Atomic Force Microscopy

MS482 Materials Characterization ( 재료분석 ) Lecture Note 11: Scanning Probe Microscopy. Byungha Shin Dept. of MSE, KAIST

Scanning capacitance spectroscopy of an Al x Ga 1Àx NÕGaN heterostructure field-effect transistor structure: Analysis of probe tip effects

The velocity dependence of frictional forces in point-contact friction

3.1 Electron tunneling theory

DRAM Failure Analysis with the Force-Based Scanning Kelvin Probe

Characterization of MEMS Devices

Atomic Force Microscopy imaging and beyond

Ultra-narrow-band tunable laserline notch filter

SENSORS and TRANSDUCERS

Linker Dependent Bond Rupture Force Measurements in Single-Molecule Junctions

Strain Measurement. Prof. Yu Qiao. Department of Structural Engineering, UCSD. Strain Measurement

NIS: what can it be used for?

Electron Interferometer Formed with a Scanning Probe Tip and Quantum Point Contact Supplementary Information

Micromechanical Instruments for Ferromagnetic Measurements

Outline Scanning Probe Microscope (SPM)

e453.eps 1 Change (or the absolute value) in the measured physical variable 2 Change in the sensor property is translated into low-power-level

Scanning Probe Microscopy. L. J. Heyderman

Chapter 3. Experimentation and Data Acquisition

ABSTRACT INTRODUCTION

The activities of micro-force measurement below 10 mn in Center for Measurement Standards

State Feedback Control for Adjusting the Dynamic Behavior of a

AFM Imaging In Liquids. W. Travis Johnson PhD Agilent Technologies Nanomeasurements Division

ME 515 Mechatronics. Overview of Computer based Control System

FINITE ELEMENT MODELLING OF COMPOSITES USING PIEZOELECTRIC MATERIAL

Improving the accuracy of Atomic Force Microscope based nanomechanical measurements. Bede Pittenger Bruker Nano Surfaces, Santa Barbara, CA, USA

NUMERICAL EVALUATION OF A TEFLON BASED PIEZOELECTRIC SENSOR EFFECTIVITY FOR THE MONITORING OF EARLY AGE COCRETE STRENGTHING

Supplementary Information for. Effect of Ag nanoparticle concentration on the electrical and

a.u Microelectromechanical Systems (MEMS). A review of existing designs of FFMs and methods AD-A J j D T IC

Institute for Electron Microscopy and Nanoanalysis Graz Centre for Electron Microscopy

Foundations of MEMS. Chang Liu. McCormick School of Engineering and Applied Science Northwestern University. International Edition Contributions by

DAMPING CONTROL OF A PZT MULTILAYER VIBRATION USING NEGATIVE IMPEDANCE CIRCUIT

Modeling, Simulation and Optimization of the Mechanical Response of Micromechanical Silicon Cantilever: Application to Piezoresistive Force Sensor

Scanning Tunneling Microscopy

Calibration of Shielded Microwave Probes Using Bulk Dielectrics

Investigation of Dynamical and Static Operation Modes of Atomic Force Microscope

Magneto-Mechanical Modeling and Simulation of MEMS Sensors Based on Electroactive Polymers

Design And Analysis of Microcantilevers With Various Shapes Using COMSOL Multiphysics Software

Principle of Magnetic Force Microscopy

DETERMINATION OF THE ADHESION PROPERTIES OF MICA VIA ATOMIC FORCE SPECTROSCOPY

Transcription:

Utah State University DigitalCommons@USU Space Dynamics Lab Publications Space Dynamics Lab 1-1-1992 Force Measurement with a Piezoelectric Cantilever in a Scanning Force Microscope J. Tansock C. C. Williams Follow this and additional works at: https://digitalcommons.usu.edu/sdl_pubs Recommended Citation Tansock, J. and Williams, C. C., "Force Measurement with a Piezoelectric Cantilever in a Scanning Force Microscope" (1992). Space Dynamics Lab Publications. Paper 127. https://digitalcommons.usu.edu/sdl_pubs/127 This Article is brought to you for free and open access by the Space Dynamics Lab at DigitalCommons@USU. It has been accepted for inclusion in Space Dynamics Lab Publications by an authorized administrator of DigitalCommons@USU. For more information, please contact dylan.burns@usu.edu.

Ultramicroscopy 42-44 (1992) 1464-1469 North-Holland Force measurement with a piezoelectric cantilever in a scanning force microscope J. Tansock and C.C. Williams Department of Physics, University of Utah, Salt Lake City, UT 84112, USA Received 12 August 1991 Detection of surface forces between a tip and sample has been demonstrated with a piezoelectric cantilever in a scanning force microscope (SFM). The use of piezoelectric force sensing is particularly advantageous in semiconductor applications where stray light from conventional optical force-sensing methods can significantly modify the local carrier density. Additionally, the piezoelectric sensors are simple, provide good sensitivity to force, and can be batch fabricated. Our piezoelectric force sensors will be described, the theoretical sensitivity and performance of piezoelectric sensors will be discussed and experimental measurements of sensitivity and imaging results will be presented. 1. Introduction The scanning force microscope (SFM) is based upon the sensing of ultrasmall forces between a nanometer scale tip and a sample surface. The typical arrangement is to have the tip attached to a cantilever which has a compliance in the range of.1 to 1 N/m. The force sensing can be achieved in several ways [1-6]. The most extensively used methods involve the use of a laser beam to measure the displacement of the cantilever by beam deflection or interferometry. These methods provide a high sensitivity to force, but require precise alignment of the optical beam with the cantilever. When imaging photosensitive materials, like semiconductors, the stray light from the illumination of the cantilever can strongly perturb the sample surface properties being measured. For these reasons, alternative force-sensing methods are attractive. Recently, Tortonese [7] demonstrated the use of piezoresistive sensing in an AFM cantilever. Previous work in this area includes a patent by Pohl [8] who described the use of an oscillating quartz force detection method, but no experimental work was reported. More recently Takata [9] demonstrated a microscope based upon the detection of AC tip/sample forces with a piezoelectric sensor at the back side of the sample. Guthner [1] has also piezoelectrically sensed the interaction between a tip and sample with a high-q quartz-tuning fork resonator. Here we describe the use of a piezoelectric bimorph cantilever for force detection, and present experimental results based upon this approach. 2. Theory and experiment Fig. 1 contains a schematic representation of a piezoelectric force sensor in the form of a bimorph. The minimum detectable force of any cantilever is always limited by thermal motion of the cantilever. Thus the sensor used to detect force becomes unimportant if the force sensitivity is dominated by the thermal fluctuations. We will now evaluate the conditions under which a piezoelectric bimorph can be thermal noise limited as a force detector. The piezoelectric voltage produced by a bimorph of length l, width w, thick- 34-3991/92/$5. 1992 - Elsevier Science Publishers B.V. All rights reserved

J. Tansock, C C. Williams / Force measured by an SFM with a piezoelectric cantilever 1465 C B C C C A Preamplifier Force Fig. 1. Schematic illustration of a piezoelectric bimorph cantilever. Fig. 2. Equivalent circuit for the detection of forces by a piezoelectric bimorph. ness t and piezoelectric stress constant g31 given by is where Y is Young's modulus and p is the density The spring constant of the cantilever is given by -- F, (1) V= ~ wt where F is the applied force below the resonance frequency. For a cantilever of rectangular cross section, the resonance frequency is given by f=.161 ~, (2) Ywt 2 k- 4l 3. (3) The smallest measurable force, as limited by thermal exitation of the cantilever, is given by [11] Fmi n = "~/ 6.18kBT~Y~Bwt 2 ql ' (4) V 1('-8 r--~ 1(-'9 Z @ U b. 1(-1.~ 1-11.,. 1(-12 (n @ O E (/) 1(-13 \ \ L. Elecfrical/Thermal Comparison KYNAR-Thin Film, t=lbum, Series Bimor 1!j~ --fib- Thermal --l--- Elecl, W=2t=36um y~ Elect, W=lOt=.18mm Elect, W=28t=.5mm 1E-14 2 4 6 8 1 12 Length/Width Ratio Fig. 3. Comparison of the performance of several preamplifier-noise-limited cantilever. bimorphs with a thermal-vibration-noise-limited

1466 J. Tansock, C.C. Williams / Force measured by an SFM with a piezoelectric cantilever where k B is Boltman's constant, T is the temperature, Q is the mechanical quality factor, and B is the detection bandwidth. To experimentally demonstrate the capabilities of the piezo sensors, a piezoelectric polymer PVDF was chosen. This polymer is produced commercially [12] and is available in thicknesses ranging from 9-5 /zm. The Young's modulus for PVDF is approximately 2 19 N/m, and the density is 18 kg/m 3. The piezoelectric stress constant is.23 Vm/N. The equivalent circuit for the piezo and preamplifier is shown in fig. 2. Here, C a is the bimorph capacitance, C c is the cable capacitance and C A is the front-end amplifier capacitance. Since the voltage produced by the deflection of the piezo must pass through the series capacitance, ideally, the front end impedance of the preamplifier should be larger than the impedance of the piezo capacitance at the operating frequency. Fig. 3 plots the amplifier-limited performance of several bimorph sensors built using PVDF films, and compares them with the thermal motion limited force sensitivity. The assumptions made in this calculation were that the capacitance of the cable was 4 pf and the front-end capacitance of the preamplifier was 15 pf. The force sensitivity is significantly improved if smaller cable and amplifier capacitances are used, since the piezo capacitances used in the calculations are of the order of 2 pf. In these calculations, a PVDF bimorph of thickness 18/xm was evaluated. For the case of a piezo of width.5 mm (open boxed curve in fig. 3), the bimorph is limited only by the thermal vibration of the cantilever for a length-to-width ratio greater than 5. In this case, the spring constant of the cantilever is.1 N/m and the resonance frequency is 46 Hz. The amplifier noise for these curves is assumed to be 5 nv/hz 1/2 which is typical for reasonably good preamplifiers. The bimorphs we built were composed of two 28 /xm thick piezo films with thin-film metal electrodes on either side. The as-purchased piezo films were glued together by applying a very small amount of epoxy to a 3 1 cm sheet of PVDF. A second sheet was then compressed against the first sheet with a vise with rubber jaws. The epoxy was then allowed to cure. The resultant series bimorph was then carefully cut out of the twolayer sheet with an unused razor blade. The cantilever used to determine the force sensitivity was triangularly shaped, the tip being the smaller end. The full length was approximately 2 mm and the base was approximately.5 mm. The cantilever resonance frequency and thickness (including epoxy) were measured to be 25 khz and 75 /xm, respectively. The triangular cantilever was held in a clamp with a free length of approximately.8 mm. Since the direct measurement of the spring constant is difficult, we estimate it here. The spring constant of a triangular bimorph can be estimated using the measured values of length and width with eq. (2). This equation can be used for our triangular cantilever by substituting l/4 for w, since the width at any point along the cantilever is just 1/4 of the distance from the tip. The effect of the epoxy cannot be determined exactly, but it is reasonable to assume that the material properties of the epoxy are not drastically different than the PVDF. If this assumption is made, the spring constant is calculated to be 19 N/m. The bimorph was used without any tip attached to it, and the shape and size of the tip were not measured; but as will be seen, the resolution achieved is consistent with a tip radius below 5,~. Fig. 4 contains the measured frequency response of the PVDF bimorph, indicating that the Q was approximately 7. The sensitivity of the bimorph was calibrated by bringing the tip close to a surface vibrating at the resonance frequency of the cantilever. The cantilever was pressed against the vibrating surface so that the tip displacement was equal to that of the surface. The minimum amplitude of vibration detectable was measured to be.5 A in a 2.6 khz bandwidth. With a spring constant of 19 N/m, this corresponds to a force sensitivity of 5.4 nn in a 2.6 khz detection bandwidth. The noise spectral density at this frequency is independent of frequency and the minimum force detectable improves as the square root of the detection bandwidth. In a 1 Hz detection band-

J. Tansock, C.C. Williams / Force measured by an SFM with a piezoelectric cantilever 1467 6 2 I I I 1 2.3 4 5 Frequency [KHz] Fig. 4. Plot of the mechanical displacement amplitude of the piezoelectric bimorph as a function of frequency. width, this minimum force corresponds to 15 pn. This sensitivity can be significantly improved. The capacitance of the cantilever in this experi- ~ sandpass Filter ment was measured to be approximately 2 pf, while the capacitance of the leads and front end of the preamplifier was measured to be approximately 1 pf. This means that the measured force sensitivity was 5 times less than under the ideal condition where the lead and front-end capacitance is small compared to that of the bimorph. In practice, this ideal condition is extremely difficult to achieve, however, increasing sensitivity by a factor of 1 should be achievable by proper design of the detection system. The experimental set-up for imaging is described in fig. 5. Since the voltage produced by a static deflection of the cantilever cannot be maintained by the piezo, an AC force detection was used in our SFM. The sample was vibrated at the resonance frequency of the bimorph. The signal from the bimorph was sent to a lock-in amplifier, where it was filtered and rectified to produce a dc output proportional to the magnitude of the AC force This signal was then sent to a conventional integrating feedback control box. The out- Precision Full Wave Recifier LOW Pass Filte~ piezo Force Transducer I- x Y z Data Acquisition and Control X Y Z T Feedback Integra o v x Y z High Voltage Amp Xin Yin Zin Zin V=V*COS(Wt), p Gain Time Constant Reference Voltage, Vr Excitation Voltage Fig. 5. Schematic illustration of the detection and feedback system for surface profiling.

1468 Z Tansock, C.C. Williams / Force measured by an SFM with a piezoelectric cantilever put of the integrator was amplified and sent to the z input of the piezo tube. The piezo cantilever was used to image two different surface structures. The first was a thinfilm gold/palladium film (2,~) on a glass microscope slide. Fig. 6 shows the topography of a 4 x 4,~ region of the surface. The image shows a later resolution on the 3.~ scale, and a vertical noise on the 1,~ scale. The large feature on the left has a vertical height of 3,~. The image was taken with a vertical vibration of the o sample of 3 A, and the image was acquired in approximately 9 s. The second surface imaged by the piezo sensor was a 1/~m period glass grating covered with 3 of gold. Fig. 7 contains the constant-force image of the grating structure. Due to the size of the tip, the vertical variation seen in the topographic image (3,~) is smaller than the grating depth. These results indicate that piezoelectric detection of surface force is a viable alternative to present force detection methods. Both the calculations and the experimental work described here were performed under conditions where the capacitance of the piezo was very small compared to the load capacitances. Substantial improvement in performance will be achieved when those capacitances are reduced. Furthermore, improvement in force sensitivity should also be possible Fig. 7. Topographic image of a 1 /zm period grating. The vertical height variation is 3 A, limited by the size of the cantilever tip. by going to thinner piezoelectric films. This can be achieved by deposition of films, rather than using prefabricated piezo sheets to construct the force sensors. 3. Conclusions We have demonstrated the use of piezoelectric bimorphs as force sensors. The sensors have demonstrated a force sensitivity of 15 pn/hz ~/2 under less than ideal conditions. The advantages of piezoelectric cantilever force detection include simplicity, good sensitivity, and possibility for batch fabrication. They also eliminate the need for optical force detection methods, which are prohibited when imaging photosensitive materials like semiconductors. We have not explored the use of charge amplifiers with the piezo sensors yet. This approach should provide the means to look at quasi-static forces, which will broaden the application of the sensors. Acknowledgement Fig. 6. A 4 x 4,~ image of a glass surface covered with 2,& of gold. The tallest feature is 3,~ in height. We would like to thank Y. Huang for his assistance and useful discussions regarding this work.

J. Tansock, C.C. Williams / Force measured by an SFM with a piezoelectric cantilever 1469 References [1] G. Binnig, C.F. Quate and Ch. Gerber, Phys. Rev. Lett. 56 (1986) 1164. [2] G.M. McClelland, R. Erlandsson and S. Chiang, Review of Progress in Quantitative Non-Destructive Evaluation, Vol. 6B (Plenum, New York, 1987) p. 137. [3] Y. Martin, C.C. Williams and H.K. Wickramasinghe, J. Appl. Phys. 61 (1987) 4723. [4] D. Rugar, H.J. Mamin, R. Erlandsson, J.E. Stern and B.D. Terris, Rev. Sci. Instr. 59 (1988) 2337. [5] G. Meyer and N.M. Amer, Appl. Phys. Lett. 53 (1988) 145. [6] D. Sarid, D. Iams and V. Weissenberger, Opt. Lett. 12 (1988) 157. [7] M. Tortonese, H. Yamada, R.C. Barrett and C.F. Quate, presented at Transducers '91, 6th Int. Conf., 24-28 June 1991, San Francisco, CA, USA. [8] D. Pohl, IBM Patent "Oscillating Quartz Atomic Force Microscope", 1987. [9] K. Takata, T. Hasegawa, S. Hosaka and S. Hosoki, Appl. Phys. Lett. 55 (1989) 1718. [1] P. Guthner, U.Ch. Fischer and K. Dransfeld, Appl. Phys. B 48 (1989) 89. [11] J. Tansock, Masters of Instrumentation Thesis, Department of Physics, University of Utah, 1991, to be published. [12] Kynar Piezo Film, Pennwalt Corporation, Valley Forge, PA 19482, USA.