Medical Cannabis Pesticide Screening using the SRI 8610C GC

Similar documents
Thermal Soil Desorber Instructions September 2006

Muliple Gas#3 plus Sulfur GC Configuration

GAS CHROMATOGRAPHY (GC)

Chemistry Gas Chromatography: Separation of Volatile Organics

Simultaneous Compound Identification and Quantification with Parallel Polyarc /FID and MS

Quantification of Pesticides in Food without Calibration using GC/FID with the Polyarc Reactor

CH 2252 Instrumental Methods of Analysis Unit V Gas Chromatography. M. Subramanian

Sulfotepp impurities in Chlorpyrifos EC formulations

STANDARD OPERATING PROCEDURES

Chapter 31 Gas Chromatography. Carrier Gas System

Method for the determination of 1,3-butadiene

1.0 Reactive Gas Chromatography Design and Setup Procedure for Catalyst Pelletization & Inlet Packing Software and Method.

Experiment DE: Part II Fisher Esterification and Identification of an Unknown Alcohol

Introduction to Capillary GC

CHAPTER 6 GAS CHROMATOGRAPHY

Experiment 8: Chlorination of 1-Chlorobutane

Analysis of Sulfur-Containing Flavor Compounds By GC/MS With A PFPD

Petrochemical. Transformer Oil Gas Analysis - TOGA

CfE Higher Chemistry. Unit 3: Chemistry in Society. Chemical Analysis as part of quality control

Chapter 27: Gas Chromatography

Gas Chromatography. Introduction

Introduction to Capillary GC

A Fast, Simple FET Headspace GC-FID Technique for Determining Residual Solvents in Cannabis Concentrates

Gas Chromatography. 1. Experiment Category: 2. Experiment Name: 3. Date and Issue number: 4. Instructor Name: 5. Institution: Ain Shams University

Determination of Volatile Substances Proof of Food Adulteration

Liquid storage: Holds the solvent which is going to act as the mobile phase. Pump: Pushes the solvent through to the column at high pressure.

L03 The Coefficient of Static Friction 1. Pre-Lab Exercises

Expectations for GC-MS Lab

2401 Gas (liquid) Chromatography

Experiment 3: Analysis of Unknown Hydrocarbons by GC, NMR, and Chemical Tests for Unsaturation and Aromaticity

Gas Chromatography (GC)! Environmental Organic Chemistry CEE-PUBH Analysis Topic 5

Analysis of Residual Solvents in Pharmaceuticals (USP<467>) with Shimadzu GC-2010 Plus and HS-10 Headspace Sampler

Activity in the FID Detection Port: A Big Problem if Underestimated

Residual Solvents in Pharmaceuticals by USP Chapter <467> Methodology

Volatile organic compounds (VOCs):

GAS CHROMATOGRAPHY. Mobile phase is a gas! Stationary phase could be anything but a gas

CHEM Experiment Five Gas Chromatographic Analysis Of A Phenolic Extract. Objectives:

Chromatographic Methods of Analysis Section: 5 Gas Chromatography (GC) Prof. Tarek A. Fayed

Understanding Gas Chromatography

Gas Chromatography. Presented By Mr. Venkateswarlu Mpharm KTPC

SPIKING ANALYSIS OF DRY GAS

Gas chromatography. Advantages of GC. Disadvantages of GC

637. Thiamethoxam. HPLC method

Gas Chromatography (GC)

Harris: Quantitative Chemical Analysis, Eight Edition CHAPTER 23: GAS CHROMATOGRAPHY

Introduction to Capillary GC. Page 1. Agilent Restricted February 2, 2011

Determination of the Chemical Formula

Abstract: An minimalist overview of chromatography for the person who would conduct chromatographic experiments, but not design experiments.

Lab 3 Guide: Gas Chromatography (GC) (Sept 8-14)

A Fast, Simple FET Headspace GC-FID Technique for Determining Residual Solvents in Cannabis Concentrates

TECHNICAL BRODIFACOUM

NCFS Sample Preparation and Instrumental Parameters

*Correspondence to:

Accurate Analysis of Fuel Ethers and Oxygenates in a Single Injection without Calibration Standards using GC- Polyarc/FID. Application Note.

Chlorinated Compounds in Hydrocarbon Streams Using a Halogen Specific Detector (XSD)

NON-METHANE ORGANIC CARBON ANALYZER (NMOC Method 25)

Bioanalytical Chem: 4590: LC-MSMS of analgesics LC-MS Experiment Liquid Chromatography Mass Spectrometry (LC/MS)

Static Headspace Blood Alcohol Analysis with the G1888 Network Headspace Sampler Application

Matter & Energy: Temperature & Heat in Physical Processes

Fundamentals of GC: Introduction: Sample introduction:

Report AFK0242/18 TABLE OF CONTENTS

GUIDELINES FOR THE DESIGN OF CHROMATOGRAPHIC ANALYTICAL METHODS INTENDED FOR CIPAC COLLABORATIVE STUDY

OPTIMISATION OF SOLID PHASE MICROEXTRACTION (SPME) CONDITIONS FOR HEADSPACE ANALYSIS OF ORGANOPHOSPHATE PESTICIDES IN WHOLE BLOOD

7 INSTRUMENTAL CHROMATOGRAPHY

Protocol Particle size distribution by centrifugal sedimentation (CPS)

Date 02/24/96 Page 1 Revison 4.0 OKLAHOMA DEPARTMENT OF ENVIRONMENTAL QUALITY METHODS 8020/8015 (MODIFIED) GASOLINE RANGE ORGANICS (GRO)

Analyzing Residual Solvents in Pharmaceutical Products Using GC Headspace with Valve-and-Loop Sampling

Identifying Pesticides with Full Scan, SIM, µecd, and FPD from a Single Injection Application

TERTIARY BUTYLHYDROQUINONE

Uncontrolled Copy. SOP-060 Chromatography, Tune Evaluation and Troubleshooting. Table of Contents. 1. Principle... 3

The Importance of Area and Retention Time Precision in Gas Chromatography Technical Note

Gas Chromatography. Chromatography Laboratory Course. Dr. Christian Jungnickel Chromatography Course GC September 2005

Lab 1a Wind Tunnel Testing Principles & Drag Coefficients of Golf balls

OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT

JWH-018 and JWH-022 as Combustion Products of AM2201

Pain-Free Melting Point Determination. James Lee, Ph.D. Stanford Research Systems

Analysis of Terpenes in Cannabis Using the Agilent 7697A/7890B/5977B Headspace GC-MSD System

Chapter 11 Conventional Gas Chromatography

Uncontrolled Copy. SOP 109 Ethylene Glycol Screen by Gas Chromatography/Mass Spectrometry. Table of Contents. 1. Principle of Assay...

DEVELOPMENT AND VALIDATION OF GC-FID METHOD FOR THE DETERMINATION OF ETHANOL RESIDUE IN MARJORAM OINTMENT

Gas Chromatography CHEM Dr. Reem M. Alghanmi st term

H 3 CO H 3 CO S CH 3

METHOD 8030A ACROLEIN AND ACRYLONITRILE BY GAS CHROMATOGRAPHY

Selective Formation of Benzo[c]cinnoline by Photocatalytic Reduction of 2,2 Dinitrobiphenyl with TiO 2 and UV light irradiation

Determination of the Equivalent Weight and the K a or K b for a Weak Acid or Base

TDTS. Keywords. Introduction. TD Operation; Calibration; Impedance; Discrimination

Exercise in gas chromatography

FORMIC ACID in URINE by GC/MS-headspace - Code GC74010

Analyzing Semi-Volatiles by GC-MS

BUTYL ALCOHOL in urine by GC-FID Code GC05510

Gas Chromatography. Rosa Yu, David Reckhow CEE772 Instrumental Methods in Environmental Analysis CEE 772 #16 2

METHOD 8033 ACETONITRILE BY GAS CHROMATOGRAPHY WITH NITROGEN-PHOSPHORUS DETECTION

Hans-Joachim Hubschmann. Handbook ofgc-ms. Fundamentals and Applications. Third Edition. Wl LEY-VCH. VerlagGmbH & Co. KG aa

Luminescence transitions. Fluorescence spectroscopy

Anethole. Gas chromatograhpy determination of trans-anethole in Spirit srinks of viti-vinicultural origin

Chem 230, Fall, 2014 Homework Set # 3 Short Answer SOLUTIONS

Chromatography Lab # 4

Reaction of Magnesium with Hydrochloric Acid

New ZB-5HT Inferno The World s Highest Temperature Non-Metal GC Column

Using a mini-gas Chromatograph (GC): Identifying Unknown Compounds

Transcription:

The SRI 8610C Gas Chromatograph (GC ) configured for Medical Cannabis Potency and Pesticide testing is shown at right. The GC is equipped with three detectors: DELCD NPD FID FID ( flame ionization detector ) NPD ( nitrogen/phosphorus ) DELCD ( dry electrolytic conductivity ) Refer to the GC manual or pdf documents on the SRI website for specific instructions on the detectors. This GC can be used for potency testing only by using the on-column injector and the FID detector. In this case only a single column is required in the column oven. Column oven On-column injector Page 1

Two additional columns can be connected to the Heated Injector. One of these columns goes to the NPD detector and the other to the DELCD detector. The Heated Injector splits the sample onto the two columns using a two hole ferrule Restek part# 20246 The Heated Injector and on column injector are side by side on the front of the GC s column oven. The Heated Injector includes a remove-able quartz lined stainless steel tube. Cannabis samples ( 100 milligrams ) are inserted into the tube and then into the Heated Injector which at 200C thermally desorbs pesticides off the cannabis and onto the two columns. C Page 2

Edit the Event table in Channel 1 of the PeakSimple software to turn the carrier gas to the Heated Injector on and off at the times shown. Enter the temperature program shown at right. The column oven starts at 100C for two minutes, then ramps at 20 degrees per minute to 300C. Manually actuate Relay A prior to the start of the analysis. Display the Pump/Relay window and click the A button to actuate Relay A. When it is actuated, Relay A turns the carrier gas flow to the heated injector off. Page 3

Take a common cotton ball and make a small wad about the size shown. Use a screwdriver or other tool to push the cotton wad about halfway down the tube. Place the tube on the balance and then tare the balance to make it read 0.000 grams Page 4

Manicure the cannabis sample and scoop 100milligrams (.1gram ) into the tube. Weigh the tube until you get approximately 100 milligrams. You do not have to get exactly 100 so long as you are close ( 95-105 mg ). The photo are right shows the weight at 99 milligrams. You can correct for the actual sample weight in the PeakSimple software after the analysis. Stuff a little more cotton into the tube to hold the cannabis sample in place. Do not pack the cotton and cannabis tightly. The cotton should just be tight enough to prevent the cannabis from escaping the tube. The cannabis should be loose, NOT packed down. Page 5

Since the injector is HOT, use a tool like a 9/16 socket to remove the septum nut. Insert the tube filled with cannabis into the injector. At this time the carrier gas is off so no gas will escape while you are inserting the tube. Gash end towards operator The tube has a gash at one end. Gash The gash end MUST be towards the operator. Page 6

Start the analysis by pushing the start button on the GC. You can also push the spacebar on the computer keyboard. The Event table in PeakSimple will de-actuate Relay A at.1 minutes into the analysis which will cause the carrier gas to strip the pesticides from the now HOT cannabis and deposit the pesticide molecules on the two columns. If your GC is equipped with a second injector and FID detector for potency measurement, you can inject the potency extract in the other injector anytime in the first 1 minute of the analysis. At 1 minute into the analysis, the carrier gas is turned off for 30 seconds. During that 30 second period remove the tube from the HOT injector using a tool to avoid burning your fingers. Place the HOT tube in a beaker to cool off. You must replace the septum nut within the 30 second window. Page 7

To calibrate the Potency channel ( channel 1 ), inject 1ul of the 333ng/ul calibration mixture into the on-column injector. You should see three equal size peaks. FID sees CBD,THC and CBN Both detectors see CPP NPD DELCD Preparation of the 333ng/ul working standard is described in another publication. The two pesticide detectors ( NPD and DELCD ) are calibrated with a pesticide standard such as Chlorpyrifos. Restek part# 32212 is 1000ug/ml ( 1000ppm ) of chlorpyrifos ( CPP ) in methanol. CPP was chosen as the calibration pesticide because it has both phosphorus ( which the NPD detects ) and chlorine ( which the DELCD detects ). So the one pesticide can be used to calibrate both detectors. Page 8

Deposit 1ul of the CPP standard on a clean cotton wad in the tube. Then desorb using the standard program and events. There should be a single peak on the NPD and DELCD channels. Create a retention window for the CPP peak in the NPD channel and another similar retention window in the DELCD channel. Notice that the retention window has Show total of all peaks selected Page 9

Create a calibration curve for the CPP in both NPD and DELCD channels. Note that the amount injected is set to 10. We injected 1ul of CPP standard which contains 1000 nanograms of CPP. Since we will be desorbing 100milligrams of cannabis, 1000 nanograms is 10ppm, hence the number 10 in the amount injected column. Amount injected is 10 Drag the retention window across the entire screen except for the first 2 minutes. This will have the effect of adding up all the peaks detected during the analysis and applying the CPP calibration to the total of the peaks, regardless of whether a particular peak is CPP or another pesticide. Unlike the potency analysis where the results are reported in Percent, the pesticide results are reported in ppm ( parts per million ) because the concentration should be very low. 1,000,000 ppm =100% 100,000ppm=10% 10,000ppm=1% 1000ppm=.1% 100ppm=.01% 10ppm=.001% 1ppm=.0001% Drag the window from 2 minutes to 11.9 minutes Page 10

The chromatograms at right show the CPP peak on all three channels. The top channel ( FID ) was injected with the CPP standard just for comparison. Normally the FID channel is used for potency ( CBD, THC, CBN ). The NPD ( channel 2 ) and the DELCD ( channel 3 ) show the CPP standard desorbed from the desorber tube. The chromatograms to the right show carbamate pesticides. You can see the NPD responds but the DELCD does not. Since the carbamates do not have chlorine this makes sense. Page 11