Northern Alberta Institute of Technology Alternative Energy Program Solar Photovoltaic Reference Array Report March 31, 2016
Goals Provide solar energy system educators, installers and adopters with real world regional performance data. Improve system design and economic modeling accuracy. Methodology Track individual module performance on as many of the most common installation angles as is possible. Roof pitches of 3/12, 4/12, 6/12 and 12/12 as well as ground installations based on site latitude and wall mounting at O were chosen. Study the impact of snow on overall performance for a term of, not less than, five years. Make findings available to any and all interested parties. Design Pairs of Conergy P-230PA solar modules with Enphase M215 microinverters are mounted at O, O, O, O, 53 O (Edmonton) 55 O (Grande Prairie) and O. One side or column acts as an unmaintained control while the other column has the snow removed for comparison. Aside from cloud cover the solar array is continuously shade free. Azimuth or facing direction is optimized for Canada, due south. Energy generated is delivered directly to the electrical grid. Project Contacts Dr. Jim Sandercock NAIT Alternative Energy Program jsanderc@nait.ca Tim Matthews NAIT Alternative Energy Program tmatthew@nait.ca 2 P a g e
Installation One The first site selected was atop NAIT s South Learning Centre located at 11762 106 Street, Edmonton, Alberta. Site latitude, 53 O. Ballast mounted. Commissioned April 1, 2012. Edmonton Project Participants Concept Solar Energy Society of Alberta, Howell Mayhew Engineering. Sponsors City of Edmonton, NAIT, Alberta Innovates Tech Futures, Howell Mayhew Engineering, Great Canadian Solar. Project Management Howell Mayhew Engineering, NAIT Alternative Energy Program. Structural Design Andy Smith. Electrical Design Howell Mayhew Engineering. Array Design NAIT Alternative Energy Program. Array Installation Great Canadian Solar. Pyranometer and Logger Installation NAIT Alternative Energy Program. Site Commissioning Howell Mayhew Engineering. Site Maintenance NAIT Alternative Energy Program. Data Management NAIT Alternative Energy Program. Reporting NAIT Alternative Energy Program, City of Edmonton. 3 P a g e
Installation Two The second site selected was atop City Hall located at 10205-98 Street, Grande Prairie, Alberta. Site latitude, 55 O. Ballast mounted. Commissioned May 24, 2013. Snow maintenance commenced September 1, 2015. Grande Prairie Project Participants Concept Solar Energy Society of Alberta, Howell Mayhew Engineering. Sponsors The Alberta Real Estate Foundation, NAIT, City of Grande Prairie. Project Management NAIT Alternative Energy Program. Structural Design Andy Smith. Electrical Design Great Canadian Solar, NAIT Alternative Energy Program. Array Design NAIT Alternative Energy Program. Array Installation Great Canadian Solar, NAIT Alternative Energy Program. Pyranometer and Logger Installation Campbell Scientific. Site Commissioning Howell Mayhew Engineering. Site Maintenance Grande Prairie City Hall Staff. Data Management NAIT Alternative Energy Program. Reporting NAIT Alternative Energy Program. 4 P a g e
Maintenance Snow is removed from the left or west column of modules only. Snow on the right or east column must not be disturbed allowing the modules to clear naturally. Snow clearing happens immediately after any snowfall or before sunrise the following morning. Pre and post cleaning photographs of the Edmonton array are taken to provide further insight into snow and wind dynamics. During the first four years of study Edmonton s array has needed an average of 24 snow clearings per winter. Data Collection Microinverters generate a snapshot of the system status every five minutes. Every five minute record contains the Timestamp, AC Voltage, DC Voltage, DC Current, Inverter Temperature and Power Production. All data points are zeroed if no power is detected from the module. A record for each module and inverter combination is collected once per week and contains a full dataset for the previous week. Seven day records for each inverter are stored as *.csv files for analysis. Data Requests Requests for data should be submitted attention Tim Matthews tmatthew@nait.ca and must include the array of interest (Edmonton or Grande Prairie), date range required, your name, e-mail address and organization. 5 P a g e
Reports: Tilt Angle Comparison (Edmonton) The following graph shows the production relationship between the different tilt angles using the highest producing angle (53 O ) as the baseline. Data from each set of left and right modules was combined for this report. Tilt Comparison (April 01, 2012 - March 31, 2016) Production Relative to Latitude Tilt (53 O ) 0.0% 10.0% 20.0% 30.0% 40.0% 50.0% 60.0% 70.0% 80.0%.0% 100.0% 77.0% 53 100.0% 99.5% 94.7% 89.6% 87.0% 6 P a g e
Reports: Snow Impact (Edmonton) Here we see the impact of removing snow from the modules versus leaving the modules to clear naturally. Only variances created by snow cover are shown. Variances resulting from manufacturing tolerances have been removed from the results. Snow Study April 01, 2012 - March 31, 2016 (Adjusted) kwh 0 200 400 600 800 1000 1200 00-0.25% 964 966 53-0.81% 1248 1259-1.73% 1237 1259-4.04% 1163 1212-4.70% 1096 1150-4.47% 1065 1115 Not Maintained Snow Removed 7 P a g e
Reports: Snow Impact, Winter Only (Edmonton) The following shows the effect of clearing during Edmonton s snow months only. Data was compiled from October 1 st to March 31 st, 2012 to 2016. Snow Study Winters Only - October 01 - March 31 (Adjusted) kwh 0 50 100 150 200 250 300 350 400 0 500-0.53% 448 1 53-2.% 5 465-4.95% 4 440-13.24% 321 370-16.92% 265 319-16.78% 247 297 Not Maintained Snow Removed 8 P a g e
Reports: Tilt Angle Comparison (Grande Prairie) The following graph shows the production relationship between the different tilt angles using the highest producing angle (55 O ) as the baseline. Data from each set of left and right modules was combined for this report. Tilt Comparison (April 01, 2015 - March 31, 2016) Production Relative to Latitude Tilt (55 O ) 0.0% 10.0% 20.0% 30.0% 40.0% 50.0% 60.0% 70.0% 80.0%.0% 100.0% 78.6% 55 100.0% 99.9% 95.2% 89.8% 86.4% 9 P a g e
Reports: Snow Impact (Grande Prairie) Here we see the impact of removing snow from the modules versus leaving the modules to clear naturally. Only variances created by snow cover are shown. Variances resulting from manufacturing tolerances have been removed from the results. Snow Study April 01, 2015 - March 31, 2016 (Adjusted) kwh 0 50 100 150 200 250 300 350 400-0.36% 5 6 55-0.72% 349 352-2.26% 346 354-3.40% 328 340-3.80% 309 321-3.85% 297 309 Not Maintained Snow Removed 10 P a g e
Reports: Snow Impact, Winter Only (Grande Prairie) The following shows the effect of clearing during Grande Prairie s snow months only. Data was compiled from October 1, 2015 to March 31, 2016. Snow Study Winters Only (October 01 - March 31) kwh 0 20 40 60 80 100 120 0-0.82% 121 122 55-2.04% 122 124-6.84% 109 117-11.69% 87 99 -.54% 72 84-15.68% 64 76 Not Maintained Snow Removed 11 P a g e