WADA Technical Document TD2015IDCR

Similar documents
WADA Technical Document TD2003IDCR

Proposal: criteria for positive identification in LC-MS analysis

MassHunter TOF/QTOF Users Meeting

TargetScreener. Innovation with Integrity. A Comprehensive Screening Solution for Forensic Toxicology UHR-TOF MS

DRD Trends in Portugal: Updates From Forensic Toxicology Services

GUIDELINES ON THE USE OF MASS SPECTROMETRY (MS) FOR IDENTIFICATION, CONFIRMATION AND QUANTITATIVE DETERMINATION OF RESIDUES CAC/GL

FUTURE CONFIRMATORY CRITERIA

Overview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada)

MassHunter Software Overview

Agilent MassHunter Profinder: Solving the Challenge of Isotopologue Extraction for Qualitative Flux Analysis

PesticideScreener. Innovation with Integrity. Comprehensive Pesticide Screening and Quantitation UHR-TOF MS

All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems

Making Sense of Differences in LCMS Data: Integrated Tools

Simplified Approaches to Impurity Identification using Accurate Mass UPLC/MS

TUTORIAL EXERCISES WITH ANSWERS

Analyst Software. Peptide and Protein Quantitation Tutorial

TOMAHAQ Method Construction

Protein Quantitation II: Multiple Reaction Monitoring. Kelly Ruggles New York University

Analysis of Biomarkers in Crude Oil Using the Agilent 7200 GC/Q-TOF

A Workflow Approach for the Identification and Structural Elucidation of Impurities of Quetiapine Hemifumarate Drug Substance

Applying MRM Spectrum Mode and Library Searching for Enhanced Reporting Confidence in Routine Pesticide Residue Analysis

New Dynamic MRM Mode Improves Data Quality and Triple Quad Quantification in Complex Analyses

1. Prepare the MALDI sample plate by spotting an angiotensin standard and the test sample(s).

Multi-residue analysis of pesticides by GC-HRMS

High-Throughput Protein Quantitation Using Multiple Reaction Monitoring

High-Field Orbitrap Creating new possibilities

Mass Spectrometry. Hyphenated Techniques GC-MS LC-MS and MS-MS

Quantitation of a target protein in crude samples using targeted peptide quantification by Mass Spectrometry

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW

Agilent TOF Screening & Impurity Profiling Julie Cichelli, PhD LC/MS Small Molecule Workshop Dec 6, 2012

Powerful Scan Modes of QTRAP System Technology

Protein Quantitation II: Multiple Reaction Monitoring. Kelly Ruggles New York University

Theory and Practical Consequences.

The Theory of HPLC. Quantitative and Qualitative HPLC

A Rapid Approach to the Confirmation of Drug Metabolites in Preclinical and Clinical Bioanalysis Studies

Multiple Fragmentation Methods for Small Molecule Characterization on a Dual Pressure Linear Ion Trap Orbitrap Hybrid Mass Spectrometer

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer

Application Note. Edgar Naegele. Abstract

Welcome! Course 7: Concepts for LC-MS

Extend Your Metabolomics Insight!

AB SCIEX SelexION Technology Used to Improve Mass Spectral Library Searching Scores by Removal of Isobaric Interferences

Highly Sensitive and Rugged GC/MS/MS Tool

NEW TOOLS FOR FINDING AND IDENTIFYING METABOLITES IN A METABOLOMICS WORKFLOW

TANDEM MASS SPECTROSCOPY

GUIDELINES ON PERFORMANCE CRITERIA FOR METHODS OF ANALYSIS FOR THE DETERMINATION OF PESTICIDE RESIDUES IN FOOD AND FEED CXG Adopted in 2017.

Peptide Targeted Quantification By High Resolution Mass Spectrometry A Paradigm Shift? Zhiqi Hao Thermo Fisher Scientific San Jose, CA

Mass spectrometry has been used a lot in biology since the late 1950 s. However it really came into play in the late 1980 s once methods were

DIA-Umpire: comprehensive computational framework for data independent acquisition proteomics

Agilent MassHunter Quantitative Data Analysis

Cerno Application Note Extending the Limits of Mass Spectrometry

Application Note. Authors. Abstract. Introduction. Environmental

Tandem mass spectra were extracted from the Xcalibur data system format. (.RAW) and charge state assignment was performed using in house software

Analysis of Opioids Using Isotope Dilution with GCMS-TQ8030 GC/MS/MS. No. GCMS No. SSI-GCMS-1401

for the Novice Mass Spectrometry (^>, John Greaves and John Roboz yc**' CRC Press J Taylor & Francis Group Boca Raton London New York

Thermo Scientific LTQ Orbitrap Velos Hybrid FT Mass Spectrometer

Identification and Characterization of an Isolated Impurity Fraction: Analysis of an Unknown Degradant Found in Quetiapine Fumarate

Chemistry Instrumental Analysis Lecture 37. Chem 4631

The Emergence of Benchtop Tandem Quadrupole Mass Spectrometers as a Routine Tool in Quantitative GC/MS/MS Applications

Guide to Peptide Quantitation. Agilent clinical research

Utility of H-SRM to Reduce Matrix Interference in Food Residue Analysis of Pesticides by LC-MS/MS Using the TSQ Quantum Discovery

Overview. Introduction. André Schreiber 1 and Yun Yun Zou 1 1 AB SCIEX, Concord, Ontario, Canada

Quantitation of High Resolution MS Data Using UNIFI: Acquiring and Processing Full Scan or Tof-MRM (Targeted HRMS) Datasets for Quantitative Assays

QUALITY CONTROL CRITERIA FOR CHEMISTRY EXCEPT RADIOCHEMISTRY.

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

MASS ANALYSER. Mass analysers - separate the ions according to their mass-to-charge ratio. sample. Vacuum pumps

An ion source performs the following two functions:

LC/MS/MS qua ntitation of β-estradiol 17-acetate using an Agilent 6460 Triple Quadrupole LC/MS working in ESI negative ion mode

GAS CHROMATOGRAPHY MASS SPECTROMETRY. Pre-Lab Questions

5Cl-AKB48 and 5Br-AKB48

Rapid and Accurate Forensics Analysis using High Resolution All Ions MS/MS

Agilent 6400 Series Triple Quadrupole LC/MS/MS Users Session

Mass Spectrometry. Ionizer Mass Analyzer Detector

Identification of Human Hemoglobin Protein Variants Using Electrospray Ionization-Electron Transfer Dissociation Mass Spectrometry

Analysis of Serum 17-Hydroxyprogesterone, Androstenedione, and Cortisol by UPLC-MS/MS for Clinical Research

What is Tandem Mass Spectrometry? (MS/MS)

An Effective Workflow for Impurity Analysis Incorporating High Quality HRAM LCMS & MSMS with Intelligent Automated Data Mining

STANDARD OPERATING PROCEDURES SOP: 1828 PAGE: 1 of 14 REV: 0.0 DATE: 05/12/95 ANALYSIS OF METHYL PARATHION IN CARPET SAMPLES BY GC/MS

Characteristic of Calibration Curve Resulting from the Use of 2 H-analogs of the Analyte as Internal Standards--Methamphetamine Example

Other Methods for Generating Ions 1. MALDI matrix assisted laser desorption ionization MS 2. Spray ionization techniques 3. Fast atom bombardment 4.

Cerno Application Note Extending the Limits of Mass Spectrometry

Lead isotope analysis: Removal of 204 Hg isobaric interference from 204 Pb using ICP-QQQ in MS/MS mode

6 x 5 Ways to Ensure Your LC-MS/MS is Healthy

SUSPECT AND NON-TARGET SCREENING OF ORGANIC MICROPOLLUTANTS IN WASTEWATER THROUGH THE DEVELOPMENT OF A LC-HRMS BASED WORKFLOW

Tandem MS = MS / MS. ESI-MS give information on the mass of a molecule but none on the structure

Choosing the metabolomics platform

Agilent All Ions MS/MS

Speciation of Bromine Compounds in Ozonated Drinking Water using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry

NOTE BY THE TECHNICAL SECRETARIAT

MetWorks Metabolite Identification Software

Metabolic Phenotyping Using Atmospheric Pressure Gas Chromatography-MS

New Approaches to the Development of GC/MS Selected Ion Monitoring Acquisition and Quantitation Methods Technique/Technology

Mass Spectrometry (MS)

A Platform to Identify Endogenous Metabolites Using a Novel High Performance Orbitrap MS and the mzcloud Library

Nature Methods: doi: /nmeth Supplementary Figure 1. Fragment indexing allows efficient spectra similarity comparisons.

Information Dependent Acquisition (IDA) 1

Introduction to GC/MS

Tutorial 2: Analysis of DIA data in Skyline

Agilent MassHunter Quantitative Data Analysis

ALIGNMENT OF LC-MS DATA USING PEPTIDE FEATURES. A Thesis XINCHENG TANG

The Truth About Dioxin Analysis: Using High Resolution GC-TOFMS and GCxGC-TOFMS to. Analytical Approaches

Transcription:

MINIMUM CRITERIA FOR CHROMATOGRAPHIC-MASS SPECTROMETRIC CONFIRMATION OF THE IDENTITY OF ANALYTES FOR DOPING CONTROL PURPOSES. The ability of a method to identify an analyte is a function of the entire procedure: sample preparation, chromatographic separation, mass analysis and data assessment. Any description of the method for purposes of documentation should include all parts of the method. The appropriate analytical characteristics shall be documented for the entire identification method and should be sufficiently proven as being fit-for-purpose through proper method validation. Laboratories shall follow the identification criteria described in this Technical Document in their analytical protocols, including the differentiation between isomers of the same substance (if this is required for the unequivocal identification of a Prohibited Substance). 1.0 Chromatographic Criteria The retention time (RT) of the analyte s chromatographic peak in the Sample shall not differ ( RT) by more than one (1) percent (%) or ±0.1 minutes (whichever is greater 1, but not exceeding the full-width-at-half-maximum, FWHM), from that of the same analyte in a spiked sample, Reference Collection sample, or Reference Material analyzed in the same analytical batch. Alternatively, the Laboratory may choose to use relative retention time (RRT) as an acceptance criterion, where the RT of the peak of interest is measured relative to a chromatographic reference compound (CRC). o If the CRC is not the stable isotope-labeled analyte, the RRT of the analyte in the Sample shall not differ by more than ±1% from that of the same analyte in a spiked sample, Reference Collection sample, or Reference Material analyzed in the same analytical batch. o If the CRC is the stable isotope-labeled analyte, the RRT of the analyte in the Sample shall not differ by more than ±0.5% from that of the same analyte in a spiked sample, Reference Collection sample, or Reference Material analyzed in the same analytical batch. 1 The whichever is greater criterion may result in a RT difference (ΔRT) unrealistically large for narrow chromatographic peaks (e.g., in UHPLC with FWHM of 1s). Since any ΔRT greater than the FWHM is generally not considered a good match in RT, a maximum ΔRT is set at the FWHM of the reference peak in the spiked sample, Reference Collection sample, or Reference Material. Page 1 of 5

2.0 Mass Spectrometric Identification Criteria Commonly employed strategies for the identification of analytes, using mass spectrometry (MS)-based techniques are often referred to as top-down and bottom-up approaches. The top-down approach involves the MS analysis of the intact analyte through the generation of substance-specific ions. The bottom-up approach involves the measurement of enzymatically or chemically produced fragments of the analyte and the identification of any such fragments. Although these terms have been particularly used for the analysis of large molecules (e.g. proteins), both approaches are valid and applicable to the MS-based identification of any analyte provided the information obtained complies with the criteria defined in this Technical Document. The specificity of the information obtained to unequivocally identify the analyte shall be established as part of the method validation process (e.g. using Basic Local Alignment Search Tool, BLAST, for analysis of a given amino-acid sequence in conjunction with a suitable database such as, for example, UniProtKB) and is not part of this document. MS criteria for identification by either scanning (e.g. Full Scan, Product Ion Scan) or non-scanning (e.g. Selected Ion Monitoring, Selected Reaction Monitoring) techniques are based on the presence and relative abundance of a number of ions which are defined by the Laboratory as diagnostic for the analyte. Any data processing (e.g. integration, subtraction, averaging, etc.) shall be performed consistently across the analytical batch. The concentration of a Prohibited Substance, or its Metabolite, or its Marker may need to be comparable (i.e. signal of the analyte within one order of magnitude) in the Sample and the spiked urine, Reference Collection sample, or Reference Material to ensure identification of the target analyte. The following identification criteria shall be applied: Each measured mass used for identification shall be within ±0.5 Da of the corresponding mass of the same ion acquired from a spiked sample, Reference Collection sample, or Reference Material analyzed in the same analytical batch. When using single-stage MS, at least three (3) diagnostic ions shall be acquired. When using multiple-stage MS (e.g. MS/MS), at least two (2) precursorproduct ion transitions (i.e. two SRM transitions) shall be monitored. The isolation width of the precursor ion shall not be more than m/z 1.3, unless required by its molecular mass and charge state. Page 2 of 5

The abundance of diagnostic ions shall be determined from the peak area or height of integrated selected ion chromatograms. This is also applicable when scan mode only is used for identification. The signal-to-noise (S/N) ratio of all diagnostic ions shall be greater than three to one (3:1). Relative Abundances shall be calculated by dividing the area or height of the ion trace of each diagnostic ion by the area or height obtained from the ion trace of the most abundant diagnostic ion taken as the base peak 2. The Relative Abundances of any of the diagnostic ions shall not differ by more than the amount specified in Table 1 from the corresponding Relative Abundances of the same ions acquired from a spiked positive control urine, Reference Collection sample, or Reference Material. If three (3) diagnostic ions or two (2) transitions are not available, a second derivative shall be prepared, or a second ionization or dissociation technique 3 shall be used. The second ionization technique shall be based on a different physical principle, i.e. chemical ionization vs. electron ionization and again should provide different diagnostic ions. It is not acceptable to utilize a technique that changes only the relative abundance of the same ions. It is not permissible, without a valid explanation 4, to collect more than the minimum required number of ions or transitions in SRM or SIM and select those with Relative Abundances within tolerance windows while ignoring other ions or transitions which would not meet the identification criteria. 2 The base peak ion shall be the most abundant diagnostic ion acquired from a spiked positive control urine, Reference Collection sample, or Reference Material. This reference base peak ion shall also be applied to the calculation of the Relative Abundances from the Sample chromatogram, even if it does not constitute the base peak ion in the Sample. 3 A different dissociation technique might be, for example, using MS 3 instead of MS 2 or using Electron Capture Dissociation (ECD) or Electron Transfer Dissociation (ETD) instead of Collision Induced Dissociation (CID). 4 A valid explanation might be, for example, clear evidence that one of the primary established ions is being interfered by a partially co-eluting substance. Page 3 of 5

Table 1. Maximum Tolerance Windows for Relative Abundances to ensure appropriate confidence in identification Relative Abundance in the reference specimen 5 (% of base peak) Maximum Tolerance Windows for the Relative Abundance in the Sample Relative Abundance (% of base peak) Examples Tolerance Window (% of base peak) 50-100 ±10 (absolute) 60 95 50-70 85-105 25-50 ± 20% (relative) 40 32-48 1-25 ±5 (absolute) 6 3 10 5-15 >0 6 8 5 Spiked sample, Reference Collection sample, or Reference Material analyzed in the same analytical batch. 6 The diagnostic ions must always be detected in the Sample (S/N > 3:1). Page 4 of 5

3.0 Definitions Diagnostic ion(s): Molecular ion or fragment ions whose presence and abundance are characteristic of the analyte and thereby may assist in its identification. A second ion belonging to the same isotopic cluster may also be used as diagnostic only when the peculiarity of the atomic composition of the fragment so justifies it (e.g. presence of Cl, Br, or other elements with abundant isotopic ions). Relative Abundance: The abundance of a particular ion relative to the most abundant ion monitored. Maximum Tolerance Window of Relative Abundances: The maximum permitted difference between the Relative Abundance of a particular ion obtained from the Sample and that obtained from the reference specimen. This may be expressed in ABSOLUTE or RELATIVE terms. Absolute: Determined by adding/subtracting the stated tolerance value to/from the Relative Abundance obtained for the monitored ion in the reference specimen. Relative: Determined by calculating the stated tolerance percentage of the Relative Abundance obtained for the monitored ion in the reference specimen and then adding/subtracting that value to/from the Relative Abundance. Scan: Acquisition of ions of a continuous range of m/z values. Selected Ion Monitoring (SIM): Acquisition of ions of one or more pre-determined discrete m/z values for specified dwell times. Selected Reaction Monitoring (SRM): Data acquired from specific product ions corresponding to m/z selected precursor ions recorded via two or more stages of mass spectrometry. SRM can be performed as tandem mass spectrometry in time or tandem mass spectrometry in space. Signal-to-Noise (S/N) Ratio: Magnitude of the instrument response to the analyte (signal) relative to the magnitude of the background (noise). Acknowledgements The WADA Laboratory Expert Group wishes to thank the experts of the WADA IDCR Working Group for their contributions to the drafting of this Technical Document: Dr. José A. Pascual, Prof. Mario Thevis, Prof. Peter van Eenoo and Dr. Terence Wan. Page 5 of 5