MAIN FEATURES USER INSTRUCTIONS

Similar documents
Please complete this form and enclose it with your carefully packed watch for repair. Add a check for postage and handling.

Operating manual for Air Commando automatic watch/ Calibers , , , 2892A2

Hey, that wasn t so hard. INSTRUCTION MANUAL AND WARRANTY

OYSTER PERPETUAL SKY-DWELLER


DOWNLOAD. Experience the magic of Customer Service and download the Zenith Watches - The Experience app!

DOWNLOAD. Experience the magic of Customer Service and download the Zenith Watches - The Experience app!

OYSTER PERPETUAL COSMOGRAPH DAYTONA

A quartz watch is a watch that uses a movement powered by a quartz crystal to. Quartz crystals are very accurate.

Reference 5204/1. Caliber CHR PS Q

User s Manual DARE TO LIV

PARTS CATALOGUE / TECHNICAL GUIDE Cal. 4F32A, 8F32A Cal. 8F33A, 8F35A

Technical Guide TG-19-C-045-E C. Made by: pelrom Date: Modifications: see last page CALIBRE 3301

Technical Guide TG-19-C-029-E E. Made by: rendav Date: Modifications: see last page CALIBRE 3303

Revised on : 06. Jun TECHNICAL GUIDE PARTS CATALOGUE. Cal.VD7Series (VD70/72/73/74/75/76/77/78/79A) ANALOGUE QUARTZ.

User manual Handbediening Mode d emploi Modalità d uso Bedienungsanleitung

MULTI-SPORTS TACTILE WATCHES USER S MANUAL

Technical Instructions 5020.B. Specification 12 ½''' Dimensions and battery. Performances. Functions. Movement height 4.40 mm

Technical Instructions cal D. Specifikation 12 ½''' Dimensions and battery. Performances. Functions. Movement height 4.40 mm

Technical Instructions 4210.B. Specification 11 ½''' Dimensions and battery. Performances. Functions. Movement height 4.40 mm

OYSTER PERPETUAL GMT-MASTER II

COMBAT COMMAND AUTOMATIC CHRONOGRAPH

BATTERY REPLACEMENT MANUAL FOR CAL. 4F (LADIES ) / 8F (GENT S) SERIES WATCHES

Technical Guide TG-19-C-063-E A. Made by : rendav Date : CALIBRE Height on movement Power reserve Number of jewels Frequency

INSTRUCTIONS MODE D EMPLOI SLIM D HERMÈS QUANTIÈME PERPÉTUEL

Revised on : 06. Jun TECHNICAL GUIDE PARTS CATALOGUE. Cal.VD8Series. (Cal.VD84/85/86/87/88A) ANALOGUE QUARTZ. SII Products

REVOLUTION TO EVOLUTION

Minute Impulse Clock Controller I01DN

The Abingdon Co. Jackie. Product Information and Manual

Electricity MR. BANKS 8 TH GRADE SCIENCE

TG MANUAL. OPEN SOURCE TIMING SOFTWARE. Oscillo-Escape. The first devices of this sort appeared around Let's say they were electronic devices.

Reference Caliber R TO 27 PS QI

The hands in 18K solid gold and large Roman Indicies are placed on the magnificent dial which is finely guilloche with a sunray design.

Introduction. Outline

Explanation: The factory restart returns the atomic clock to an out-of-the-box state and often resolves an issue.

O P E R A T I N G M A N U A L

HIKE Cat. No

English... Page 1. Français... page 79. Español... página 163

Technical Instructions 4003.B. Specification 12 ½''' Dimensions and battery. Performances. Functions. Movement height 4.40 mm

INSTRUCTION MANUAL for No. 45 Altimeter-Compass

Time Management Systems

Press Release. Patek Philippe, Geneva Baselworld Patek Philippe Nautilus & Aquanaut Casual elegance paired with impressive complications

Acceleration/Velocity/Displacement VIBRATION METER

URWERK presents the EMC: The first high-end mechanical watch with artificial intelligence

PARTS LIST / TECHNICAL GUIDE

QUALITY FEATURES ST-4000 CHRONO

Acceleration, Velocity, Separate probe VIBRATION METER Model : VB-8202

IWC SCHAFFHAUSEN SENDS NEW PILOT S WATCHES OUT ONTO THE RUNWAY

Cambridge International Examinations Cambridge International General Certificate of Secondary Education

VIBRATION METER Acceleration & Velocity Model : VB-8201HA

IROX-ER + IROX-XL. Bedienungsanleitung Mode d emploi Modo di uso User manual

C1 Grand Malvern Moonphase. Owner s handbook

U.S. Atomic Clock & Weather Station. Instruction Manual

OYSTER PERPETUAL EXPLORER II

ATT 310 USER MANUAL

Non - Contact Forehead Infrared Thermometer. Care Q7 USER MANUAL - 1 -

Issue date: 30. Apr TECHNICAL GUIDE PARTS CATALOGUE. Cal.NH25/26 AUTOMATIC MECHANICAL. SII Products

PAST AND PRESENT IN A FUSION OF DIGITAL MECHANICS

THE NEW JAEGER-LECOULTRE POLARIS COLLECTION

TRADE CATALOGUE

2018 COLLECTION JEWELRY & WATCHES

UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS International General Certificate of Secondary Education

Winding the mainspring, adjusting the hand, day/date is done by the below procedure. day adjustment hand adjustment date adjustment

Assembly and Operation Manual. April 2016

HOWEVER, ONLY ONE CAN BE YOURS.

AN PHILOSOPHY CABEST

FIELD SPECTROMETER QUICK-START GUIDE FOR FIELD DATA COLLECTION (LAST UPDATED 23MAR2011)

OPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820

Voyage In the sea History

GPS Scout Backtrack Altimeter Model: GP123 USER MANUAL

mechanically regulated, hence making no use of electric, magnetic or electromagnetic means.

zulu - inca - kundalini - cozmo Welcome to the Ownership of a YES Watch.

Thor Guard Data Reference Guide SUPPORT DOCUMENT

MODE button MAX/MIN button CHANNEL button / C/ F / RCC button SNOOZE / LIGHT button Battery compartment A/C in-jack 3. 4.

THE AMC PROJECT A world first in the history of watchmaking

Built on the expertise of yesterday, crafted with today s technology, your TYPE 1 is designed for tomorrow. Benoît Mintiens Founder and Creative Mind

UA-SS FAQS UA-SS FAQS

Technical Instructions 6203.B. Specification 11 ½''' Dimensions and battery. Performances. Functions. Movement height 3.30 mm

Gra n d e Co m p l i c a t i o n

Authenticity and Condition Checklist

BULOVA MODELS. Selfwinding and. Watches. Specifications 12EBA 12 EBAD 12 ECAD 12 EBACD 12 ECACD. . i -... ~.~.. '. Movement: Self-winding mechanism

B Left-hand case side (x1) F

OPERATING INSTRUCTIONS

HIGHLY ACCURATE PENDULUM INSTRUMENT ECE-492/3 Senior Design Project Spring 2013

Determination of the Equivalent Weight and the K a or K b for a Weak Acid or Base

U S E R G U I D E E N G L I S H

Minimum (-31) every 10 s -35 (-31)

Operating Instructions 5 Day Weather Station with Color Screen Model: DG-TH8805 INDOOR UNIT

Casio G SHOCK watches Specifications

06MAR THU 12: User Manual

CONTENTS. Batteries. La Crosse Technology, Ltd Page 1

44 Force extension characteristics for a spring / elastic material

Inverted Pendulum System

Brand Story. Each Perry Ellis Watch is thoughtfully engineered with

Historiques Triple calendrier Historiques Triple calendrier 1948

CLOCKS MARATHON WATCH COMPANY LTD.

Learning to work with SPS Structured Beam. (June 14-21, 2004) Lev Uvarov

COMMANDO PROFESSIONAL

ACTIVITY 2: Motion and Energy

Hadrons Desktop U.S. Atomic Clock & Weather Station

Transcription:

USER INSTRUCTIONS

CONQUEST V.H.P. Based on its many years of experience with quartz, the winged hourglass brand is now presenting its new Conquest V.H.P., equipped with an exclusive, cutting-edge movement. This movement is renowned for its high degree of precision for an analog watch (± 5 sec / year) and its ability to reset its hands after an impact or exposure to a magnetic field, using the GPD (Gear Position Detection) system. These attractive features are likely responsible for its exceptional movement status, to which a very long battery life and a perpetual calendar must be added. In the true essence of Conquest, the ultimate sports line, this exceptional timepiece brings together high technicality and dynamic aesthetic. The Conquest V.H.P. has thus positioned itself as the standard-bearer of extreme precision. These watches are available in the 3 hands/calendar (41 and 43 mm diameter cases) and chronograph (42 and 44 mm diameter cases) versions. The chronograph displays hours, minutes and seconds, a 30-minute counter at 3 o clock, a 12-hour counter at 9 o clock and a 60-second counter in the centre. On each model, changes are made using the intelligent crown, while the E.O.L. indicator can preventatively signal the end of battery life. The Conquest V.H.P. collection models display blue, carbon fiber, silver-coloured or black dials.

MAIN FEATURES ULTRAPRECISION OF ± 5 SECONDS PER YEAR The watch ensures the display of hours, minutes and seconds to an accuracy of ±5 sec/year. This extreme accuracy is achieved through an ultra-precise quartz combined with time display correction in the event of a disturbance. GPD SYSTEM The GPD system (Gear Position Detection) is the watch s key device. It allows to automatically reset the hands after a shock or exposure to a magnetic field, either immediately, or at 3am if the problem isn t resolved right away. The GPD system also includes automatic correction at 3am every three days to ensure the precision. Magnetism Sensors detect the presence of magnetic fields. Above a certain threshold, the display freezes, although the time is still being counted. As soon as the watch moves away from the magnetic fields, the display immediately corrects itself. Shock In case of a shock up to 500G, the display is immediately corrected. In the event of stronger shock, the correction occurs automatically thanks to the GPD system. PERPETUAL CALENDAR The watch is equipped with a perpetual calendar that no longer requires correcting the date. The calibre does not allow one to move the time forward or backward more than one day, in order to avoid disrupting the perpetual calendar. LONG-LIFE BATTERY The battery lasts more than 4 years and the watch signals the end of battery life by making one of its hands jump every five seconds. If the battery is not replaced during the E.O.L. (end of life) phase, the system goes into E.O.E (end of energy) mode by setting the watch hands to 12 o clock. You have then 6 months to change the battery. SMART CROWN The smart crown allows to set the time minute by minute or hour by hour (quick setting), by turning the crown either slowly or vigorously. When changing the time (in summer/winter, for example), the movement automatically repositions the second and minute hands to the exact position of the previous time, therefore ensuring extra precision.

CONQUEST V.H.P. 3 HANDS INTELLIGENCE Perpetual calendar on all versions. Calendar position detection. The shock detector detects shock and holds the hand back during the shock. The GPD system helps correctly reposition the hands after shocks (if they are very strong and the shock detector was unable to hold the hands back) or after exposure to magnetic fields. Smart crown. Time zone change (hour movement) without losing the second. Very high accuracy in time setting to the second. DISPLAY Hours, minutes, seconds in the middle. Date window. Perpetual Calendar. E.O.L. and E.O.E. indicators (preventively signals the end of battery life). ADVANTAGES No more date correction needed. The watch autocorrects itself in case of shock or after exposure to magnetic fields to maintain its display accuracy. Manipulations are simplified thanks to the smart crown. NTC E56 3 HANDS L288.2 DIAMETER HEIGHT MOTORS ACCURACY 12½ 28.20 mm. 3.90 mm. High speed (400Hz, or 400 steps per second). Three (3) independent two-way motors. Typically ±5 seconds /year.

CONQUEST V.H.P. CHRONOGRAPH INTELLIGENCE Perpetual calendar on all versions. Calendar position detection. The shock detector detects shock and holds the hand back during the shock. The GPD system helps correctly reposition the hands after shocks (if they are very strong and the shock detector was unable to hold the hands back) or after exposure to magnetic fields. Smart crown. Time zone change (hour movement) without losing the second. Very high accuracy in time setting to the second. DISPLAY Hours, minutes and small seconds at 6 o clock. Date window. Perpetual calendar. 30-minute counter at 3 o clock. 12-hour counter at 9 o clock. 60-second counter in the middle. Timing in ADD and SPLIT modes. E.O.L. and E.O.E. indicators (preventively signals the end of battery life). ADVANTAGES No more date correction needed. The watch autocorrects itself in case of shock or after exposure to magnetic fields to maintain its display accuracy. Manipulations are simplified thanks to the smart crown. NTC E57 CHRONOGRAPH L289.2 DIAMETER HEIGHT MOTORS ACCURACY 13¼ 29.89 mm. 3.90 mm. High speed (400Hz, or 400 steps per second). Five (5) independent two-way motors. Typically ±5 seconds /year.

FIRST USE AND RESYNCHRONISATION THE WATCH IS DELIVERED IN ENERGY-SAVING MODE The crown is extended, the hands are at twelve o clock. Once the crown has been pushed in, the watch automatically changes to the Swiss time and date. It must then be set to the local time. If the user extends the crown once again, the hands return to twelve o clock and the watch goes back into energy-saving mode after one minute. Once the crown has been pushed in, the watch automatically changes to the local time. ADJUSTING THE TIME Pull the crown out to position. Adjust the hands by turning the crown in either direction. The time can be set minute by minute or hour by hour (quick setting), by turning the crown either slowly or vigorously. Push the crown back in to position. The perpetual calendar no longer requires correcting the date. RESYNCHRONISATION If the battery is exhausted (or removed from the movement more than one day), the watch needs to be totally resynchronised (reprogrammed). All the functions are affected. If the battery is removed from the movement less than one day, only the hour needs to be resynchronised. Only approved service centres are authorised to change the battery and synchronise Conquest V.H.P. watches.