Schedule for a proficiency test

Similar documents
CHEK Proficiency study 642. Migration of formaldehyde from melamine kitchenware. Date 7 July 2016 Version 1 Status Final Report number CHEK

Analysis For quality control the reference material is analysed at the same time and in the same manner as other samples.

Proficiency test SPIL-3 (2017) Organic matter, phosphorus, chloride, sulphate and suspended matter in wastewater (synthetic wastewater, effluent)

Protocol for the design, conducts and interpretation of collaborative studies (Resolution Oeno 6/2000)

METALS IN WATER BATCH: MATERIAL. Description. Cu, Ni and. Quantity 5% (V/V). Use. the mark in. such a way. water. The are given in QC METAL HL2

Analysis For quality control the reference material is analysed at the same time and in the same manner as other samples.

It is important that the batch numbers of the reference material and on the certificate are identical.

Analysis For quality control the reference material is analysed at the same time and in the same manner as other samples.

Practical Statistics for the Analytical Scientist Table of Contents

BATCH: MATERIAL. Description. water. Quantity QC METAL LL2. is prepared (V/V). Use. be used in the quality. nitric acid is. certificate. intended use.

CHEK Proficiency study 644. Solvents in adhesive. Date 15 October 2016 Version 1 Status Final Report number CHEK

Proficiency test SPIL-4 (2017) Nitrogen parameters in wastewater (effluent)

Analysis For quality control the reference material is analysed at the same time and in the same manner as other samples.

QC METAL LL3 CERTIFICATE FOR MERCURY INSTRUCTIONS FOR USE OF THE REFERENCE MATERIAL

TNI V1M Standard Update Guidance on Detection and Quantitation

The AAFCO Proficiency Testing Program Statistics and Reporting

Part 14: Water quality Sampling. Guidance on quality assurance and quality control of environmental water sampling and handling

CHEK Proficiency study 664. Solvents in adhesive. Date 3 July 2017 Version 1. Report number CHEK Final CHEK proficiency study July 2017

CHEK Proficiency study 671. CMI, MI and free formaldehyde in body lotion. Date 30 November 2017 Version 1. Report number CHEK

BATCH: VKI least 97%. Use. Analysis For quality ples. Production. in accordance

Proficiency test SPIL-2 (2018) Nitrogen parameters in wastewater (synthetic wastewater, effluent)

SWGDRUG GLOSSARY. Independent science-based organization that has the authority to grant

Calculation of Measurement Uncertainty

Proficiency test SPIL-4 (2015) Nitrogen parameters in wastewater (effluent)

Results of Proficiency Test Benzene & Toluene March 2017

Method Validation. Role of Validation. Two levels. Flow of method validation. Method selection

Unit 27 One-Way Analysis of Variance

ISO/TS TECHNICAL SPECIFICATION. Water quality Guidance on analytical quality control for chemical and physicochemical water analysis

ALLOWAY METHOD OUTLINE

Reproducibility within the Laboratory R w Control Sample Covering the Whole Analytical Process

Review Inter-laboratory studies in analytical chemistry. Edelgard Hund, D.Luc Massart, Johanna Smeyers-Verbeke

Results of Proficiency Test OPP, PCP and TeCP in textile December 2016

Philipp Koskarti

It is important that the batch numbers of the reference material and on the certificate are identical.

OA03 UNCERTAINTY OF MEASUREMENT IN CHEMICAL TESTING IN ACCORDANCE WITH THE STANDARD SIST EN ISO/IEC Table of contents

Analysis of interlaboratory comparison when the measurements are not normally distributed

Method Validation and Accreditation

IN SOIL QC OIL VKI BATCH: Use. and the sum. same. assess the. Analysis Extract and. analyse the. al growth and. humidity absorption.

Validation and Standardization of (Bio)Analytical Methods

Analysis For quality control the reference material is analysed at the same time and in the same manner as other samples.

Proficiency test SPIL-2 (201 13) Quality documentation July 2013

Results of Proficiency Test Rubber/Compounds May 2005

Uncertainty of Measurement (Analytical) Maré Linsky 14 October 2015

The Role of Proficiency Tests in the Estimation of Measurement Uncertainty of PCDD/PCDF and PCB Determination by Isotope Dilution Methods

Report on the 2011 Proficiency Test for the determination of T-2 and HT-2 toxins in wheat flour

Laboratory ID. Laboratory Name. Analyst(s) Auditor. Date(s) of Audit. Type of Audit Initial Biennial Special ELCP TNI/NELAP.

EPA's Revision to the 40 CFR Part 136 Method Detection Limit (MDL) Procedure

How s that *new* LOD Coming? Rick Mealy WWOA Board of Directors DNR LabCert

Proficiency test SPIL-4 (2016) Nitrogen parameters in wastewater (effluent)

The Swedish National Geodata Strategy and the Geodata Project

Results of Proficiency Test Phthalates in Plastics May 2015

Source Protection Zones. National Dataset User Guide

COMPARISON OF ALTERNATIVE MEASUREMENT METHODS

A basic introduction to reference materials. POPs Strategy

Copyright ENCO Laboratories, Inc. II. Quality Control. A. Introduction

Reference Materials and Proficiency Testing. CropLife International Meeting October 2015 Gina M. Clapper

Statistical Reports in the Magruder Program

Proficiency test SPIL-1 (2014) Organic matter, phosphorus, chloride, sulphate and suspended matter in wastewater (effluent)

Hach Method Spectrophotometric Measurement of Free Chlorine (Cl 2 ) in Finished Drinking Water

Item Reliability Analysis

Proficiency test SPIL-2 (2017) Nitrogen parameters in wastewater (untreated sewage)

Validation of analytical methods. Adrian Covaci Toxicological Center, University of Antwerp

Proposed Procedures for Determining the Method Detection Limit and Minimum Level

ŞİŞLİ-İSTANBUL. NİŞANTAŞI-İSTANBUL

TC2 EXPERIENCES IN COLLABORATIVE STUDIES, METHOD VALIDATION AND PROFICIENCY TESTING

DOE S RADIOLOGICAL TRACEABILITY PROGRAM FOR RADIOANALYTICAL MEASUREMENTS: WORK IN PROGRESS

(Re)introduction to statistics: dusting off the cobwebs

Revision: 11 (MBAS) ALLOWAY METHOD OUTLINE. Standard Laboratory Method:

QUESTIONNAIRE: REACH INTRODUCTION

Analytische Qualitätssicherung Baden-Württemberg

Nordic Innovation Centre Holbergsgate 1, 0166 OSLO Telephone Fax

Hach Method Total Organic Carbon in Finished Drinking Water by Catalyzed Ozone Hydroxyl Radical Oxidation Infrared Analysis

Introduction to the evaluation of uncertainty

NORDTEST NT TR 537 edition :11

ISO INTERNATIONAL STANDARD. Statistical methods for use in proficiency testing by interlaboratory comparisons

METHOD 8033 ACETONITRILE BY GAS CHROMATOGRAPHY WITH NITROGEN-PHOSPHORUS DETECTION

ICP Waters report 129/2016

ESTA governance Quality Assurance System for Seed Treatment and Treated Seed

Participants in the Proficiency Test THM 02/2016

Uncertainty of Measurement

Homogeneity of EQA samples requirements according to ISO/IEC 17043

TNI Standard; EL-V1M4 Sections and (Detection and Quantitation) page1 of 8. TNI Standard VOLUME 1 MODULE 4

IAEA s ALMERA Effort towards Harmonization of Radioanalytical Procedures

Analytische Qualitätssicherung Baden-Württemberg

This procedure describes the monitoring activities in a laboratory quality control (QC) program to ensure the quality of test results.

FRANKLIN UNIVERSITY PROFICIENCY EXAM (FUPE) STUDY GUIDE

QC METAL LL3A CERTIFICATE FOR MERCURY INSTRUCTIONS FOR USE OF THE REFERENCE MATERIAL

F I N A L R E P O R T

Understanding and Interpreting Soil and Plant Tissue Lab Reports

Development of a harmonised method for specific migration into the new simulant for dry foods established in Regulation 10/2011

centro tecnológico Development of reference materials: a case study on packaging material as a source of taints in foods

UNCERTAINTY ANALYSIS FOR LABORATORY ACCREDITATION. Peter B. Crisp. Fluke Precision Measurement Ltd, 52 Hurricane Way, Norwich, UK

QUESTIONNAIRE: REACH INTRODUCTION

Sample Homogeneity Testing

Nanomaterials, REACH and CLP - what is going on at the regulatory front

Provläsningsexemplar / Preview INTERNATIONAL STANDARD ISO Second edition

S.O.P. no : ARO/126 Title: Preparation and validation of lyophilised Page : 1 of 6 urinary reference materials. Revision : 1 Date :

2016 No. 410 (W. 128) WATER, ENGLAND AND WALES. The Water Supply (Water Quality) (Amendment) Regulations 2016

Worldwide Open Proficiency Test for X Ray Fluorescence Laboratories PTXRFIAEA13. Determination of Major, Minor and Trace Elements in a Clay Sample

Proficiency test SPIL-2 (2011) Nitrogenparameters in wastewater (sewage)

Transcription:

Schedule for a proficiency test Once a laboratory haegistered the year s programme the interaction between the laboratory and Eurofins Miljø A/S will be according to the schedule described below. 1 Reminder Approximately one month before a proficiency test, Eurofins Miljø sends a reminder for all registered participating laboratories. The reminder advises the laboratory of the expected arrival date for samples. Samples Whenever possible, samples are made up as sample pairs (split-level samples). A sample pair consists of two samples that are identical or almost identical. The difference between the two samples in a sample pair is a small and known (to Eurofins Miljø but not to the participants) difference in concentration of the parameters to be measured. The purpose of having this small difference is to ensure that the participants do not inadvertently reduce the difference between two results of a duplicate measurement, thereby appearing to have repeatability, which is too optimistic. Before statistical treatment of the data the small, added concentration (spike) iemoved from the results, leaving data that can be regarded as a duplicate measurement. 3 Shipment of samples Samples are shipped in a way to allow arrival at the participating laboratories -3 days before the proficiency test. The samples are accompanied by an instruction on sample handling, sample identification and where appropriate the procedure for sample preparation from concentrates. A list of identification numbers used for analytical methods are also sent. Eurofins Miljø requests that the laboratorieeport the method employed using these identification numbers. The information of the methods used is not important for the proficiency test as such but when laboratories identify the methods used it becomes possible to extract information of comparability of methods from the data. The list of method identification numbers includes methods used by many laboratories and a code for other methods. If a laboratory uses the number for other methods it will aid the development of the system if the precise reference for the method is given. Thereby new methods may be added to the list of methods and the new method may be compared to others at an early stage. Comparison of methods is financed by sources other than the proficiency tests. 4 Analysis The participants analyse the parameters in the samples according to the registration of the laboratory. The analysis should be performed using the same procedures as for all other sampleeceived by the laboratory. Calibration, blank correction, and correction for recovery is performed exactly as the laboratory outine procedures. Occasionally, Eurofins Miljø may include a sample to be used for blank correction with proficiency test samples. If this is the case the instruction accompanying the samples will show this clearly. 5 Reporting of results The laboratory reportesults using the result form, which was sent together with the samples. In order to perform valid statistical data analyses, the laboratories are requested to report results using one significant figure over the number usually employed in similar routine analyses. Results are sent to Ernst & Young P/S (an independent firm of accountants) by e-mail, post or telefax. The completed form must arrive at Ernst & Young P/S no later than the date shown on the form as the deadline. Ernst & Young P/S gives the code numbers, keeps the information on the identity of the participants and sends the results with code number to Eurofins Miljø. The deadline is normally approximately two weeks after the proficiency testing date. Results that arrive after the deadline are normally not included in the data analysis or reports from Eurofins Miljø. It is important to everyone - the participants as well as Eurofins Miljø - that the results Are reported on time. Late arriving results will mean either delay in statistical data analysis or the late arriving results are not included. This means that the statistical basis for the proficiency test becomes less substantial than intended. Are reported using the units specified. Are reported showing the method identification number or precise reference if the method is not included in the list of method identification numbers. It is not possible to correct data that have already been reported.

6 Report from Eurofins Miljø A/S 6.1 Participants results Approximately three weeks after the deadline for reporting results, Eurofins Miljø issues a report to each participant. Ernst & Young P/S sends the report to the laboratory. The report contains a sheet showing the laboratory s own results (see example in annex 1). Eurofins Miljø makes every effort to avoid transcription errors but nevertheless, participants are requested to check that their results are entered correctly. Eurofins Miljø will of course correct any typing error and issue a revised report. The report also includes an assigned value for the concentration of all parameters and an evaluation of the stability and homogeneity of the samples. This evaluation shows the degree to which the samples are considered adequate for evaluating the performance of participants. The report contains a comparison of the laboratory s data to the average for all participants, giving an assessment of the performance relative to other participants. The deviation of the laboratory s data from the assigned value and the standard deviation (measure of repeatability) are estimated. The laboratory may use these values for assessment against official requirements or the laboratory s own specifications of quality. In the report, result are compared to quality requirements in Danish legislation. 6. Overview of all data and general quality of analyses The report also includes a table showing the results from all participants for every parameter. Thereby the laboratory may compare its own results to all other data or to results from other laboratories using the same method. For every parameter a page is included showing the statistical parameters for the general quality of analyses and a plot showing all data graphically. The statistical data analysis is performed according to ISO 575:1994, Accuracy (trueness and precision) of measurement methods and results. Section 8 gives a summary of the statistical estimations. A Youden plot is used to illustrate the data. The plot shows the results of one sample as a function of the result of the other sample in a sample pair. The Youden plot gives an immediate idea of the dominating sources of error in the results. Laboratories having results in the upper left or lower right hand corner of the diagram have analyses dominated by random error. On the other hand, laboratories having results close to the 45 line shown in the plot, but far away from the assigned value have results dominated by systematic error. B, µg/l N 0 15 10 5 NH4-N, µg/l N sample pair AB Spike value 0 of B 9 1 3 Youden plot, 11 16 15 10 1 14assigned value 47 0 0 5 10 15 0 A, µg/l N Laboratories omitted from the above Youden plot : 6 17 5 An example of a Youden plot is shown above. 13A 13B assigned value B=A 6.3 Assigned value Eurofins Miljø A/S assigns a value for each parameter. The assigned value is Eurofins Miljø best estimate of the true concentration of the sample. This is the value used to estimate the accuracy of participants results. The principles used to assign values to the samples are described below. Assigned values in synthetic samples are calculated from the weight of chemicals and water used to prepare the samples. Assigned values in natural samples are consensus median values either from all participants or from a limited number of participants who have been selected based on good accuracy in two or more previous proficiency tests of the same parameter. For certain parameters, such as for example biochemical oxygen demand, the Danish Environmental Protection Agency, regulation on quality requirements for environmental measurements, specifies the method. In such cases only results from participants using the specified method are included in the assigned value. Eurofins Miljø report to participants describes how the assigned value was determined for all parameters. On rare occasions the structure of the data may be such that an estimated assigned value would be extremely uncertain. In such cases no assigned value is estimated. This situation may arise in case

several methods giving incomparable results are used, in case of few participants or large variability. 7 Quality assurance of the proficiency test Eurofins Miljø A/S gives high priority to quality assurance and documentation of the quality of proficiency tests in order that participants, accreditation bodies and other users of the proficiency tests may be confident that the results from a participant adequately reflect the participant s performance. Therefore, Eurofins Miljø has an extensive quality system for performance of proficiency tests and a well-validated software programme for statistical data analysis. Eurofins Miljø constantly looks for improvement by standardising and simplifying routines whenever possible. Eurofins Miljø also performs measurements and tests to control and document the performance of the proficiency test. The documentation for preparation and control of proficiency test samples is submitted to DANAK, Danish Accreditation, in a report: Quality Documentation. Thieport is also available to all interested parties on the Eurofins Miljø home page (www.eurofins.dk/ proficiencytest) approximately six weeks after the deadline for submitting participants results. 7.1 Sample preparation Sample preparation is documented in work sheets on which every step in the preparation process is documented and signed by the staff member who performed the step in question as well as a control. Sample preparation is summarised in a table including the concentrations calculated from formulation. The table is included in Eurofins Miljø Quality Documentation report. 7. Homogeneity and stability All samples distributed in proficiency tests are checked by a programme of analysis to ensure that samples are homogeneous and stable. The analyses include those parameters in each proficiency test posing the greatest risk for instability or contamination that may result in heterogeneity. The programme of analyses takes into account that the statistical tests performed must have optimal power. Thieduces the risk of erroneously accepting a batch of samples of inferior quality. The programme is based on Eurofins Miljø many year of experience with the proficiency tests offered. All measurement of the control programme as well as the statistical analyses used to conclude on homogeneity or stability and the conclusions of the tests are documented in Eurofins Miljø Quality Documentation report. If the difference cannot be attributed to outlying data, the sample preparation and Eurofins Miljøs control measurements are scrutinised in an attempt to identify the cause of the deviation. On this basis it is concluded if the assigned value is to be main- Homogenety and stability are evaluated using the target standard deviation for reproducibility σ^ we use 0.5 times * the required maximum deviation from the assigned value stipulated in the Danish EPA regulation on quality reguirements for environmental measurements. 7.3 Spike In most cases samples are prepared as split-level samples, that is sample pairs where one may have received a spike of a small amount of the parameter in question. When calculating repeatability from sample pairs, after removing by calculation the small spike added, it is necessary that the true spike is identical to the spike calculated. To test this, the average difference between results of the two samples in a sample pair is calculated for each participant after removing the added spike. A t-test at 95% confidence level is performed to see if the calculated difference deviates significantly from the expected value of zero. If the difference found by participants differs significantly from zero it is concluded that participants do not measure the spike calculated. In such cases the sample preparation is scrutinised to detect any possible error in preparation. The spike measured by Eurofins Miljøs control programme is calculated and checked, and the participants results are scrutinised to ensure that obvious outliers do not skew the average difference. On this basis it is decided if the spike calculated is maintained. A recommendation is given in case it is deemed necessary to increase the range of requirements for repeatability due to the uncertainty of the size of the spike. All data, conclusions and evaluations are documented in the report: Quality Documentation. 7.4 Assigned value A reliable assignment of the concentration of parameters in proficiency test samples is essential for assessment of the performance of participants. The overall average of all participants results is compared to the assigned value using a t-test at the 95% confidence level. If the test is significant it is concluded that the participants do not measure an average value, which is identical to the assigned value. In case the test shows significance the results of the participants is scrutinised because a significant difference in most cases is due to outliers or outlying methods. If this is the case, the outlying results are excluded manually and the test repeated.

tained or changed. A recommendation is given in case it is deemed necessary to increase the range of requirements for accuracy due to the uncertainty of the assigned value. All data, conclusions and evaluations are documented in the report: Quality Documentation. 8 Statistical data analysis Statistical data analysis is performed according to ISO575:1994, Accuracy (trueness and precision) of measurement methods and results. 8.1 Outlier tests Cochran s test is performed to identify any data set with an unusually large standard deviation. This is followed by Grubbs test to identify any data set with an average result, which deviates from the overall average for all participants. Any data set which deviates significantly at the 99% confidence level (outliers) in these tests, are excluded from further data analysis. Data sets, which deviate only at the 95% confidence level (stragglers) are retained. An outlier is a result, which deviates significantly from the main body of data, either because of unusually large standard deviation (Cochran) or because of a deviating average (Grubbs). An outlier test does not take into consideration requirements for quality. 8. General quality of analyses The general quality of analyses is found by analysis of variance (ANOVA) of the results from all data sets. This analysis yields the between laboratories variance, between samples variance and residual variance. The repeatability standard deviation ( ) and reproducibility standard deviation ( ) are estimated as follows: = residual variance = ½ * (between laboratories variance - residual variance) = + Furthermore the overall average and median for all participants data are estimated. Comparison of the average and the median to the assigned value yields an estimate of the overall trueness of the results from all participants. Statistical analyses for proficiency tests having very few participants may be by robust statistics. 9 Symbols and abbreviations Tables < Less than - results are not included in calculations U, UL, ** Manually excluded results UC, C** Cochran outlier. Results are not included in statistical data analysis UG, G** Grubbs outlier. Results are not included in statistical data analysis Graphical presentations < Less than - results are not included in the graphical presentations U, UL, ** Manually excluded results are not included in the graphical presentations Assigned value (= true value) Statistical symbols µ Assigned value p Number of laboratories included in statistical data analysis. This corresponds to the total number of reported results minus manually excluded results (**) minus Cochran outliers (UC) and minus Grubbs outliers (UG) n Number of results included in statistical data analysis m Average of all not-excluded results M Median d The average difference between the two results of a sample pair after subtraction of the added spike t Test value in Student s t-test p The level of probability in a statistical test s Standard deviation F Test value in an F-test s i Standard deviation for participant i, corresponding to the variability by repeated measurement of a sample Standard deviation within a laboratory Repeatability variance Standard deviation between laboratories Laboratory variance Reproducibility standard deviation Reproducibility variance = + CV r Coefficient of variation within a laboratory(s. r 100)/μ CV R Total coefficient of variation (s. R 100)/μ

Annex 1 - Laboratory esults Proficiency test Samples forwarded: 5/3-01 Title: SPIL-1 (01) Date of proficiency testing: 15/3-01 Subject: Organic matter, phosphorus, chloride and sulphate in waste water Deadline: /4-01 Sample type: Natural waste water treated sewage Report: 3/4-01 Parameters: CODCr, BOD5, BOD7, NVOC, TP, PO4, SSTS, Cl, SO4 Quality documentation May 01 Organiser: Eurofins Miljø A/S Homogeneity Stability Determination assigned value Homogeneity tests have been performed for NVOC, TP and SS. The tests show that the samples are homogeneous. The samples for determination of TP, Cl and SO4 and ampoules for CODCr, NVOC, BOD were stabilized by autoclaving. Experience from many proficiency tests shows that samples are stable after this treatment. The assigned values are calculated on the basis of median values from the laboratories using the method prescribed in Danish legislation and the spiked amount added to the samples (theoretically calculated spike value). Results of laboratory: 999 Reported Accuracy Precision Parameter Sample Unit Result Method no. Deviation from assigned value, semigraphically Assigned value Grubbs outlier % deviation from ass. value Evaluation Lab. stand.dev. s(i) <1 sr 1- sr > sr CODCr A1 mg/l O.5 9-6.7 16 A.47 A B1 6.0-6.7 3 A BOD5 w. ATU A1 mg/l O 3.40 1-4.00 15 A 0.56 A B1 4.90 + 4.71 4 A BOD7 w. ATU A1 mg/l O - 4.30 B1-5.01 NVOC A1 mg/l C 7.88 1-9.19 14 A 0.049 A B1 7.81-9.19 15 A Total phosphorus A mg/l P 0.06 1-0.13 3 A 0.010 I B 0.300 + 0.90 3 A Suspended matter A3 mg/l 44.0 1-45.4 3 A 1.7 A B3 35.0-38. 8 A Chloride A mg/l 86 4-301.6 5 A 1.8 A B 308-31.0 4 A Sulphate A mg/l 13 4-19.8 5 A 0.5 A B 147-153.1 4 A Cochran outlier Evaluation Evaluation: A Z-score below. The result is acceptable according to Danish EPA requirements. A* Z-score between and 3. The result is questionable. I Z-score higher than 3. The result is NOT acceptable according to Danish EPA requirements.