Advances in Interference Removal for Accurate Arsenic Analysis in Food and Beverages

Similar documents
Analytical Approaches to Arsenic

IMPROVING DATA QUALITY WITH ADVANCED INSTRUMENTATION UTILIZING MULTIPLE INTERFERENCE REDUCTION TECHNOLOGIES

Rapid determination of five arsenic species in polished rice using HPLC-ICP-MS

Accurate Analysis of Trace Mercury in Cosmetics using the Agilent 8900 ICP-QQQ

Agilent Technologies at TIAFT 2013

Total elemental analysis of food samples for routine and research laboratories using the Thermo Scientific icap RQ ICP-MS

Intercomparison of Extraction and Analytical Techniques for Inorganic Arsenic in Seaweed

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Analysis of Trace Metal Impurities in High Purity Hydrochloric Acid Using ICP-QQQ

Low Level Detection of Priority Inorganic Pollutants in Water. Anthony Neumann, MSc Darren Crichton, BSc

Arsenic Speciation in Chicken. Mary Carson, Ph.D. FDA/CVM/OR/ Division of Residue Chemistry

Speciation of Bromine Compounds in Ozonated Drinking Water using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry

Determination of challenging elements in ultrapure semiconductor grade sulfuric acid by Triple Quadrupole ICP-MS

Total Elemental Analysis of Food Samples for Routine and Research Laboratories, using the Thermo Scientific icap RQ ICP-MS

A Comparison of Arsenic Speciation

Application note. Trace level analysis of sulfur, phosphorus, silicon and chlorine in NMP using the Agilent 8800 Triple Quadrupole ICP-MS

A Comparison of Three Methods for Arsenic Speciation in Biological Tissues. May Nguyen Brooks Rand Labs Seattle, WA

High Sensitivity HPLC Analysis of Perchlorate in Tap Water Using an Agilent 6460 Triple Quadrupole LC/MS System

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

Basic and Application Inductively coupled plasma mass spectrometry (ICPMS)

Determination of underivatized aflatoxins B2, B1, G2, and G1 in ground hazelnuts by immunoaffinity solid-phase extraction with HPLC-FLD detection

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

Trace elemental analysis of distilled alcoholic beverages using the Agilent 7700x ICP-MS with octopole collision/ reaction cell

speciation in water Page 1

Agilent ICP-MS. Fundamentals of ICP-MS Analysis and Its Applications for Low Level Elemental Determination in Cannabis

Implementing EPA Method 6020 with the Agilent ICP-MS Portfolio

Simple, reliable analysis of high matrix samples according to US EPA Method 6020A using the Agilent 7700x/7800 ICP-MS

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

Determination of trace elements in ultrapure semiconductor grade sulfuric acid using the Agilent 8900 ICP-QQQ in MS/MS mode

Agilent s Solutions for Nanoparticles Analysis ICP-MS, ICP-MS/MS, software. Alain Desprez Agilent Technologies

Agilent s New 8800 ICP-QQQ. Transforming ICP-MS Technology

Highly Sensitive and Rugged GC/MS/MS Tool

Comparing Collision/Reaction Cell Modes for the Measurement of Interfered Analytes in Complex Matrices using the Agilent 7700 Series ICP-MS

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

Benzene Contamination in BabyFood and Beverages by New Generation of Static Headspace Autosampler coupled to Fast GC-TOFMS

Application Note. Author. Abstract. Food Safety. Syed Salman Lateef Agilent Technologies, Inc. Bangalore, India

Characterization of Arsenic Species in Apple Juice using a NexSAR HPLC-ICP-MS Speciation Analysis Ready Solution

Quantification of growth promoters olaquindox and carbadox in animal feedstuff with the Agilent 1260 Infinity Binary LC system with UV detection

Impact factor: 3.958/ICV: 4.10 ISSN:

Accurate analysis of neptunium 237 in a uranium matrix, using ICP-QQQ with MS/MS

J. Serb. Chem. Soc. 78 (10) S117 S126 (2013) Supplementary material. SUPPLEMENTARY MATERIAL TO Analytical methods for arsenic speciation analysis

Rapid Detection of Americium-241 in Food by Inductively-Coupled Plasma Mass Spectrometry

Accurate measurement of elemental impurities in metals and metal alloys using the Thermo Scientific icap TQ ICP-MS

Simultaneous Arsenic and Chromium Speciation by HPLC/ICP-MS in Environmental Waters

Rapid Analysis of High-Matrix Environmental Samples Using the Agilent 7500cx ICP-MS. Application. Author. Abstract. Introduction.

RP-HPLC Method Development and Validation of Dapagliflozin in Bulk and Tablet formulation

A RP-HPLC METHOD DEVELOPMENT AND VALIDATION OF PARA- PHENYLENEDIAMINE IN PURE FORM AND IN MARKETED PRODUCTS

Using UHPLC-Triple Quadrupole MS/MS to Detect the Presence of Bark Extract and Yohimbine Adulteration in Dietary Supplements and Botanicals

Lead isotope analysis: Removal of 204 Hg isobaric interference from 204 Pb using ICP-QQQ in MS/MS mode

Analysis of Low-Calorie Sweeteners by Liquid Chromatography-Tandem Mass Spectrometry

Agilent 8900 Triple Quadrupole ICP-MS

DISCLAIMER: This method:

Using TOF for Screening and Quantitation of Sudan Red Colorants in Food Application

Applications of ICP-MS for Trace Elemental Analysis in the Hydrocarbon Processing Industry

Multi-residue analysis of pesticides in crude food extracts using a simple extraction technique and LC/MS/MS

VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION

High Throughput Water Analysis using Agilent 7900 ICP-MS coupled with ESI prepfast

Multi-residue analysis of pesticides by GC-HRMS

Analysis of Arsenic, Selenium and Antimony in Seawater by Continuous-Flow Hydride ICP-MS with ISIS

Thermo Scientific icap RQ ICP-MS: Typical limits of detection

Handling Interferences in the Modern Laboratory with Advanced Triple Quadrupole ICP-MS Technology

Agilent 6460 Triple Quadrupole LC/MS System with an Agilent 1290 Infinity LC For Multi-Plant Growth Regulator Analysis in Grapes

Determination of iopromide in environmental waters by ion chromatography-icp-ms

Determination of ultratrace elements in photoresist solvents using the Thermo Scientific icap TQs ICP-MS

Determination of 17 Organotin Compounds in Beverages Using Triple Quadrupole GC-MS/MS System

Authors: C. Derrick Quarles, Jr. *, Patrick Sullivan, M. Paul Field, Hwan Kim, and Daniel R. Wiederin

The Agilent 7700x ICP-MS Advantage for Drinking Water Analysis

Thermo Scientific icap TQ ICP-MS: Typical limits of detection

Determination of Chromium in Gelatin Capsules using an Agilent 7700x ICP-MS

Quantitative analysis of small molecules in biological samples. Jeevan Prasain, Ph.D. Department of Pharmacology & Toxicology, UAB.

Determination of Polyacrylic Acid in Boiler Water Using Size-Exclusion Chromatography with Charged Aerosol Detection

DEVELOPMENT OF HPLC METHOD FOR ANALYSIS OF NITRITE AND NITRATE IN VEGETABLE

Definitive EtG/EtS LC-MS/MS Analysis:

Application note. Accurate determination of sulfur in biodiesel using Isotope Dilution-Triple Quadrupole ICP-MS (ID-ICP-QQQ) Petrochemical

APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS KEY WORDS. Simultaneous high-throughput screening of melamine (MEL) and cyanuric acid (CYA).

Multi-Element Analysis of Cannabis using the Agilent 7800 ICP-MS

Enhancing the productivity of food sample analysis with the Agilent 7700x ICP-MS

Aminoglycosides in Milk Using Agilent Bond Elut Plexa SPE, Agilent Poroshell 120, and LC/Tandem MS

Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS

Extraction of Aflatoxins and Ochratoxin from Dried Chili Using ISOLUTE. Myco Prior to LC-MS/MS Analysis

CHAPTER INTRODUCTION OF DOSAGE FORM AND LITERATURE REVIEW

Analysis of Synthetic Cannabinoids and Metabolites: Adding New Compounds to an Existing LC-MS/MS Method

Fundamentals of the ICP-MS Technique and How to Resolve Issues for Pharmaceutical Materials (In 20 Minutes) Tim Shelbourn, Eli Lilly and Company

Quantitative Analysis of Water-Soluble B-Vitamins in Cereal Using Rapid Resolution LC/MS/MS. Application. Authors. Abstract.

16 Malachite green 17 Leucomalachite green

Application Note. Gas Chromatography/Mass Spectrometry/Food Safety. Abstract. Authors

A Newly Approved ASTM Standard For Analysis of Thiophene in Benzene Using a Pulsed Flame Photometric Detector (PFPD)

Tyler Trent, Applications Sales Specialist, Teledyne Tekmar P a g e 1

Sensitive Femtogram Determination of Aflatoxins B 1 , B 2 , G 1. and G 2. in Food Matrices using Triple Quadrupole LC/MS. Authors.

Dartmouth Trace Element Analysis Core: Lab methods

Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma

Identification and Quantitation of Pesticides in Chamomile and Ginger Extracts Using an Agilent 6460 Triple Quadrupole LC/MS system with Triggered MRM

Determination of Benzoic acid Residue from Fruit Juice by Gas chromatography with Mass spectrometry Detection Technique

The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity

Identification and Quantitation of PCB Aroclor Mixtures in a Single Run Using the Agilent 7000B Triple Quadrupole GC/MS

Trace Analyses in Metal Matrices Using the ELAN DRC II

Determination of Essential, Therapeutic. in Biological Materials; Applications of

Key Analytical Issues: Sample Preparation, Interferences and Variability. Tim Shelbourn, Eli Lilly and Company

Simple and Reliable Soil Analysis using the Agilent 7800 ICP-MS with ISIS 3

Simplified workflows for the Thermo Scientific icap TQ ICP-MS

Transcription:

Advances in Interference Removal for Accurate Arsenic Analysis in Food and Beverages National Environmental Monitoring Conference 2013 Austin TX Steve Wilbur and Amir Liba Agilent Technologies

Let s Define the Problem -Medically, legally, analytically Arsenic is toxic (but not all forms are toxic to the same degree) Arsenic is present in drinking waters and many foods (but the form varies) Toxicity depends on the form or species (but species conservation during sample prep is challenging) Arsenic is challenging to determine by ICP-MS because it is monoisotopic, has a high ionization potential, and is subject to many common spectroscopic interferences.

Inorganic arsenic-related health effects Inorganic arsenic is a well-characterized Group 1 human carcinogen Lung, bladder, skin and others Transplacental carcinogen Noncancer health effects Cardiovascular disease Diabetes mellitus Dermal effects Neurological effects/deficits Immunologic effects Fertility effects Birth defects Respiratory effects Acute toxicity Irritation of lungs, throat, stomach, intestines and skin Death within hours after ingestion of sufficient dose

Arsenic in water inorganic arsenic As(III) and As(V) British Geological Survey

As species* *Analyst. 2004, 129, 373-395

More arsenic species* *Analyst. 2004, 129, 373-395

As Speciation - Toxicity Toxic! Less-Toxic Non-Toxic? Many As species exist the inorganic As species are known to be toxic and most organic species are relatively harmless to humans. The potential toxicity of some species, such as the huge variety of arsenosugars, has not yet been established.

Arsenic in Food Risk assessments are based on inorganic As In food, high total As is not always equal to high inorganic As Arsenic from water is 100% bioavailable; this might not be the case for food Safe drinking water limits are set assuming long-term exposure Dietary choices are varied BUT rice-subsistence diets could be equal to or greater than safe exposure limits Early life exposure is important, should limit exposure during this development period

Arsenic in seafood Main source of total As to diet Fish can be > 1 ppm 40 ppm total As Arsenic is present almost exclusively as arsenobetaine: NON-TOXIC CH 3 CH 3 As + COO - CH 3

Arsenic in poultry http://us.medage.net/upload/roxarsone USP24_20050704.jpg Roxarsone Also p-arsanilic acid, nitarsone, carbarsone, arsanilate sodium Additive in poultry and swine feed since mid- 1940s Approved for growth promotion, improved pigmentation, coccidiostat, treatment of swine dysentery In poultry production: 88% raised using roxarsone 2010 estimate In swine and turkey production: unknown % Single domestic producer July 8 2012 Pfizer suspends marketing of roxarsone in the US

What about arsenic in chicken meat 2006 IATP: Playing Chicken: Avoiding Arsenic in Your Meat

Arsenic in rice USA long grain rice had the highest mean arsenic level in the grain at 0.26 µg As g -1 arsenic in rice contributes considerably to arsenic ingestion in subsistence rice diets Williams et al ES&T 39: 2005

Surveys and market basket studies Survey of As and its speciation in rice products such as breakfast cereal, rice crackers and Japanese rice condiments. Sun et al 2008, Environment International

As (ng/g) in formula powder Arsenic in baby formula powder 250 Toddler formulas using organic brown rice syrup as sweetener 200 150 Baby formula powders using non rice based sweeteners 100 50 0 BF 1 BF 2 BF 3 BF 4 BF 5 BF 6 BF 7 BF 8 BF 9 BF 10 BF 11 BF 12 BF 13 BF 14 BF 15 BF 16 BF 17 Formula lab ID #

Arsenic in Apple Juice Agilent application note 5951-0622EN

Solving the Analytical Problems Separating the toxic from the non-toxic species with reliable species conservation and recovery Determining the concentration of toxic species (and others) in the presence of significant interferences and sometimes without access to species specific standards or reference materials Doing the above with sufficient accuracy, precision and method robustness

ICP-MS as an LC detector for As Specific and Selective: ICP-QMS Arsenic is determined at mass 75 and the chloride interference is separated, in time, by the chromatographic system or removed by the collision cell. ICP-QQQ Arsenic is determined as AsO (m/z=91) after the first quad removes all other potential interferences at m/z=91 Wide dynamic Range: the ICP-MS detector is linear over large concentration range (10e9) - range limited by chromatographic system No structural information ID by retention time Accurate quantification for unknown As compounds possible using Compound Independent Calibration

Arsenic Speciation with LC-ICP-MS Complete isocratic separation of AsB & Cl from inorganic As Column G3288-80000 (4.6 x 250 mm) Guard Column G3154-65002 *Surface Aminated Polymer Substrate Mobile Phase (Basic): 2 mm phosphate buffer solution (PBS) ph 11.0 adjusted with NaOH 0.2 mm EDTA 10 mm, CH 3 COONa 3.0 mm NaNO 3 1% ethanol Agilent Application Note: Routine Analysis of Toxic Arsenic Species in Urine Using HPLC with ICP-MS, 5989-5505EN, by Tetsushi Sakai and Steven Wilbur, Agilent Technologies

Arsenic species in apple juice A simple, reliable method A simple filtration (preserve the species, good recovery) No sample digestion or stabilization was performed, as aggressive sample separation steps could cause species inter-conversion. LC-ICP-MS Method Instrument 1200 LC Column G3288-80000 (4.6x250mm) Mobile phase 2.0mM PBS, 0.2mM EDTA, 30mM CH3COONa, 2.0% EtOH ph 11.0 adjusted by 1M NaOH Flow rate 1.0 ml/min Injection Vol. 100µL Oven Temp. Ambient Sample Preparation Filter1 Membrane filter: Millex-LH 0.45μm PTFE 25mm (Millipore corporation) Filter2 DDS Cartridge: TOYOPAK ODS M (TOSOH corporation) Dilution 1:2 with de-ionized water August 9, 2013

S/N for As Species in Apple Juice Limit of Detection ~ 0.02ppb* Peak# Compound RT[min] Height Area Noise S/N Noise Type 1 AB 2.799 1797 22142 133 13.51 Peak-to-Peak 2 DMAA 3.564 2254 24465 133 16.95 Peak-to-Peak 3 As(III) 4.118 1910 24759 133 14.36 Peak-to-Peak 4 MMAA 6.574 1602 29631 133 12.04 Peak-to-Peak 5 As(V) 10.580 1082 30762 133 8.13 Peak-to-Peak S/N report for 0.1ppb Standard 7700x (intensity scale 20,000 counts) S/N between 8 and 17 depending on compound *proposed new FDA regulation is 10 ppb August 9, 2013

As Species Calibrations by LC 1200 with 7700x Overlaid chromatograms for As calibration standards: 0, 0.01, 0.05, 0.1, 0.5ppb As Intensity scale 20,000 counts August 9, 2013

As Species in Apple Juice Apple Juice 1 Apple Juice 4 Chromatograms for 6 different commercially available apple juices (As(III) and As(V) highlighted). All chromatograms shown on an intensity scale of 20,000 counts Samples diluted 2x with deionized water prior to analysis As species varied between samples, but all levels low (<1.5ppb each species in undiluted juice) Apple Juice 2 Apple Juice 5 Apple Juice 3 Apple Juice 6 August 9, 2013

As Species Stability (precision and robustness) Overlaid chromatograms for 7 separate injections of Apple Juice 1 spiked with 0.5ppb each As species August 9, 2013

Quantitative Results for As Species in Apple Juice by single quad ICP-MS AB DMAA As(III) MMAA As(V) Sample Name Dilution Conc. [ ug/l ] Conc. [ ug/l ] Conc. [ ug/l ] Conc. [ ug/l ] Conc. [ ug/l ] Apple Juice 1 2 0.036 0.163 0.717 ND 0.492 Apple Juice 2 2 0.026 0.019 0.04 ND 0.044 Apple Juice 3 2 0.020 0.230 0.874 1.371 0.573 Apple Juice 4 2 0.039 0.179 0.982 1.266 1.479 Apple Juice 5 2 0.043 0.180 1.243 0.678 0.536 Apple Juice 6 2 0.036 0.203 1.086 ND 0.051 All individual species results less than 1.5ppb in the undiluted juice samples. Total inorganic As (sum of As(III) and As(VI) less than 2.5ppb in all samples August 9, 2013

Precision for As Species in Apple Juice Stability data (n=7) for spiked apple juice. RT and concentration results RT stability around 0.2 to 0.3%RSD Concentration stability ~1%RSD AB DMAA As(III) MMAA As(V) Sample Name RT Conc. [ug/l] RT Conc. [ug/l] RT Conc. [ug/l] RT Conc. [ug/l] RT Conc. [ug/l] Spike 50-1 2.758 0.944 3.604 1.010 4.178 1.675 6.493 0.916 10.812 1.213 Spike 50-2 2.769 0.935 3.614 1.015 4.178 1.677 6.493 0.911 10.802 1.209 Spike 50-3 2.769 0.939 3.614 1.004 4.178 1.655 6.503 0.903 10.762 1.207 Spike 50-4 2.758 0.936 3.614 0.999 4.168 1.646 6.503 0.921 10.762 1.194 Spike 50-5 2.758 0.955 3.614 1.009 4.178 1.635 6.473 0.923 10.762 1.176 Spike 50-6 2.748 0.925 3.634 0.996 4.158 1.650 6.473 0.901 10.762 1.230 Spike 50-7 2.758 0.924 3.624 0.991 4.178 1.648 6.463 0.916 10.772 1.203 %RSD 0.265 1.149 0.263 0.851 0.189 0.936 0.247 0.927 0.199 1.387 August 9, 2013

Preliminary Conclusion not too bad Can this be improved using ICP-QQQ? Fast the entire separation was complete in under 12 min, and sample to sample is about 14 min. linearity the MS detector shows excellent linearity across the analytical range Specificity the common non-toxic arsenic did not overlap with the species desired to be determined and the interfering peak from ArCl is also chromatographically separated. Simplicity the existing method used for As was modified to be tolerant of the changed matrix (apple juice) and was seen to be a very flexoble method.

Reminder Why >90% of Quadrupole ICP-MS Have Collision/Reaction Cell Interference Removal Arsenic (mass 75) 1ppb Standard No Gas Mode As (1ppb) Background peaks from Ar 2 + As can be measured accurately in simple samples using conventional ICP-QMS However, Food, Whole Blood, Tissue, or Urine samples are complex matrices

As Measured at m/z 75 in Cl-Matrix is Overlapped by ArCl Polyatomic Interference 1ppb As in 5% HCl In conventional noncell ICP-MS, As is affected by polyatomic interferences in Clmatrix (ArCl at m/z 75) As (1ppb) ArCl Cl 2

As Measured at m/z 75 in Cl & Ca-Matrix is Overlapped by ArCl/CaCl Polyatomic Interferences 1ppb As in 5% HCl, 1ppb As in 5% HCl + 100ppm Ca As (1ppb) CaCl ArCl In conventional noncell ICP-MS, As is affected by polyatomic interferences in Cland Ca-matrix (ArCl and CaCl at m/z 75) Cl 2

As Measured at m/z 75 in Ca/Cl-Matrix He Mode Removes ArCl/CaCl Polyatomic Interferences 1ppb As in 5% HCl, 1ppb As in 5% HCl + 100ppm Ca all interferences removed Problem solved As (1ppb) As (1ppb) in: 5% HCl 5% HCl + 100ppm Ca He mode removes Cland Ca-based polyatomic interferences, giving reliable and consistent results in variable matrices

However, He Mode Can t Remove ALL Possible Interferences 1ppb As + 1ppm Nd/Sm in He Mode Nd & Sm form 2+ ions. Isotopes at mass 150 appear at 75 (half true mass) 2+ interferences not removed Nd ++ and Sm ++ Collision mode with KED removes polyatomic interferences, but is not effective against doublycharged interferences As (1ppb)

Conventional ICP-QMS Can Use Reaction Mode to Avoid 2+ Interferences on 75 As 75 As + + O 2 <cell gas> 91 AsO + 40 Ar 35 Cl +, 40 Ca 35 Cl +, Sm ++, Nd ++ + O 2 no (or very slow) reaction Reaction gas (O 2 ) 40 Ar 35 Cl +, 40 Ca 35 Cl, Nd ++ /Sm ++ 40 Ar 35 Cl, 40 Ca 35 Cl, Nd ++ /Sm ++ 75 As 91 AsO + 75 As 91 AsO + Analyte and interfering ions enter reaction cell As + reacts with O 2 cell gas to form AsO + product ion Quad set to AsO + product ion mass (m/z 91) rejects original 40 Ar 35 Cl +, 40 Ar 35 Cl +, Nd ++ /Sm ++ interfering ions

O 2 Reaction Mode on Conventional ICP-QMS - (8800 in single quad mode) As + is converted to AsO + and moved to mass 91 avoids interferences 1ppb As, + 5% HCl + 100ppm Ca, + 1ppm Nd/Sm Trace Sr contamination from 100ppm Ca As (as AsO + ) (1ppb) As (1ppb) in: 5% HCl 5% HCl + 100ppm Ca 1ppm Nd/Sm O 2 cell gas reaction mode in Single-Quad mode gives consistent results for As in varied matrices including 1ppm Nd/Sm

So ICP-QMS Reaction Mode Solves the Problem? Not Quite! ICP-QMS with O 2 cell gas avoids 40 Ar 35 Cl + 40 Ca 35 Cl + and Nd ++ /Sm ++ overlap on 75 As +, but AsO + product ion at m/z 91 can be overlapped 40 Ar 35 Cl, Nd ++ /Sm ++ Reaction gas (O 2 ) 40 Ar 35 Cl +, Nd ++ /Sm ++ 75 As 91 Zr + 91 AsO + 91 Zr + 75 As 91 AsO + Analyte and interfering ions enter reaction cell As + reacts with O 2 cell gas to form AsO + product ion. Not all Zr + reacts to form ZrO + (some Zr + remains) Quad set to AsO + product ion mass (m/z 91) rejects original 40 Ar 35 Cl +, 40 Ar 35 Cl +, Nd ++ /Sm ++ interfering ions but cannot remove 91 Zr + Conventional Quadrupole ICP-MS cannot reject on-mass interferences that overlap cell-formed analyte reaction product ions

Product Ion Overlaps with Conventional ICP-QMS O 2 Mass-Shift Mode As + is converted to AsO + and measured at mass 91 overlap from 91 Zr + 1ppb As, + 5% HCl, + 5% HCl + 100ppm Ca, + 1ppm Nd/Sm, +0.5ppm Zr Sr contamination from 100ppm Ca As (as AsO + ) (1ppb) 0.5ppm Zr AsO + product ion suffers from Zr + interference on conventional quadrupole ICP-MS. In theory Zr + reacts with O 2 cell gas to As (1ppb) in: form ZrO +, but not 5% HCl complete removal. 5% HCl + 100ppm Ca 1ppm Nd/Sm 0.5ppm Zr

The solution: ICP-MS/MS Mass-Shift with O 2 Cell Gas Same reaction with O 2 cell gas is also used on 8800 ICP-MS/MS: 75 As + + O 2 <cell gas> 91 AsO + 40 Ar 35 Cl +, 40 Ca 35 Cl +, Sm ++, Nd ++ + O 2 no reaction BUT Q1 of 8800 rejects 91 Zr + ions that would overlap AsO + at mass 91 40 Ar 35 Cl + 40 Ca 35 Cl Nd ++ /Sm ++ 75 As + 91 Zr Reaction gas (O 2 ) 40 Ar 35 Cl +, 40 Ca 35 Cl +, Nd ++ /Sm ++ 75 As 16 O + 91 Zr + Q1 set to m/z 75, so rejects all ions except m/z 75. 91 Zr at mass 91 is rejected 75 As 91 AsO + As + reacts with O 2 cell gas to form AsO + product ion. 40 Ar 35 Cl +, 40 Ca 35 Cl +, Nd ++ /Sm ++ don t react and stay at m/z 75 Q2 set to m/z 91, AsO + product ion mass rejects original on-mass interferences

ICP-MS/MS O 2 Mass-Shift Mode for As Consistent Results in Any Matrix Same matrices as before ALL overlaps are removed by MS/MS 1ppb As, + 5% HCl + 100ppm Ca, + 1ppm Nd/Sm, +0.5ppm Zr No Sr peaks (all rejected by Q1) As (as AsO + ) (1ppb) No overlap from Zr With ICP-MS/MS, AsO + product ion is completely free from any overlap. 91 Zr + is rejected by Q1 so doesn t overlap at mass 91 As (1ppb) in: 5% HCl 5% HCl + 100ppm Ca 1ppm Nd/Sm 0.5ppm Zr

As Species Sensitivity with 8800 ICP-QQQ Comparison of 0.5ppb As species standard with 8800 (left) and 7700x (right) same intensity scale. Sensitivity ~ 2x higher with 8800 significant improvement in S/N ICP-triple quad ICP-single quad August 9, 2013

8800 ICP-QQQ As Species at Low-Levels Overlaid chromatograms and stability data (n=3) for 0.1ppb standard repeated start, middle and end of sequence (7 hours total) RT %RSD: 0.2% to 0.6% Conc %RSD: 2.5% to 4% 75 AB 75 DMAA 75 As(III) 75 MMAA 75 As(V) Conc. RT [ ug/l ] Area RT Conc. [ ug/l ] Area RT Conc. [ ug/l ] Area RT Conc. [ ug/l ] Area RT Conc. [ ug/l ] Area 0.1ppb 2.803 0.097 45568 3.592 0.098 55186 4.128 0.096 51251 6.576 0.100 61409 10.350 0.103 70294 0.1ppb 2.813 0.093 43686 3.602 0.093 52340 4.118 0.090 47972 6.546 0.098 59949 10.299 0.101 69028 0.1ppb 2.782 0.100 47263 3.592 0.100 56301 4.108 0.097 51792 6.495 0.105 64045 10.309 0.106 72305 %RSD 0.57 3.63 3.93 0.16 3.72 3.74 0.24 4.01 4.11 0.63 3.57 3.36 0.26 2.44 2.34 August 9, 2013

As Speciation in Apple Juice by ICP-QQQ LOD ~ 2x better, and absolutely no interferences 40

Conclusions LC-ICP-QMS is a simple, robust, sensitive technique for determining toxic arsenic species in foods and beverages Single quad ICP-MS using either He mode or O 2 reaction mode can be used effectively, but some risk of residual interferences remains LC-ICP-QQQ is just as simple and reliable as LC-ICP-QMS but has the added advantage of even lower LOD, and higher confidence that no unknown interferences are present.