Comparison of some human tissues and some commonly used thermoluminescent dosimeters for photon energy absorption

Similar documents
Journal of Chemical and Pharmaceutical Research

Chapter 3. Effective atomic numbers and electron densities for some scintillators and plasticizers

Studies on mass attenuation coefficients, effective atomic and electron numbers for Cd 1-x Zn x Te alloy at photon energies of 10 to 100 kev

A comprehensive study on energy absorption and exposure buildup factors for some Vitamins and Tissue Equivalent Materials

Exposure Buildup Factors for Heavy Metal Oxide Glass: A Radiation Shield

Measurement of linear and mass attenuation coefficient of alcohol soluble compound for gamma rays at energy MeV

Gamma dosimetric parameters in some skeletal muscle relaxants

Geant4 Monte Carlo code application in photon interaction parameter of composite materials and comparison with XCOM and experimental data

Evaluation of gamma shielding parameters of bismuth oxide filled polymer composites

Vanadium Compounds: As Gamma Rays Shielding Material

DETERMINATION OF X-RAY TOTAL ATTENUATION COEFFICIENT IN Zr, Ag, In FOR ENERGY RANGE BETWEEN kev

International Journal of Scientific & Engineering Research Volume 9, Issue 1, January ISSN

Journal of Chemical and Pharmaceutical Research, 2012, 4(9): Research Article

Energy Absorption Buildup Factor Studies In Some Soils

Research Article Energy Absorption and Exposure Buildup Factors of Essential Amino Acids

An analytic review of the different methods for evaluating the Z-effective of the series of glass [Li 2 O B 2 O 3 SiO 2 MnO]

Journal of Radiation Protection and Research

ESTIMATION OF 90 SCATTERING COEFFICIENT IN THE SHIELDING CALCULATION OF DIAGNOSTIC X-RAY EQUIPMENT

Shielding of Ionising Radiation with the Dosimetry & Shielding Module

Radiation Protection Dosimetry (2006), Vol. 118, No. 3, pp Advance Access publication 6 October 2005

Monte Carlo simulation for the estimation of iron in human whole blood and comparison with experimental data

A COMPUTER PROGRAM FOR THE DECONVOLUTION OF THERMOLUMINESCENCE GLOW CURVES K. S. Chung 1,, H. S. Choe 1, J. I. Lee 2, J. L. Kim 2 and S. Y.

Measurements of K- shell production cross-section and fluorescence yield for Y element

Radhakrishnan B*, Kurup P G G**, Ramakrishnan G***, Chandralingam S****

Experimental and Theoretical Investigation of Gamma Attenuation of Building Materials

A N Singh, S N Singh & L L Singh

Measurement of atomic number and mass attenuation coefficient in magnesium ferrite

JRPR. A Study of Shielding Properties of X-ray and Gamma in Barium Compounds. Original Research. Introduction

Chapter V: Cavity theories

Ba (Z = 56) W (Z = 74) preferred target Mo (Z = 42) Pb (Z = 82) Pd (Z = 64)

Characterization of Low-Energy (6-30 kev) Response of Polish TLDs (MTS-N, MCP-N) with Synchrotron Radiation and Determination of Some TLD Quantities.

X-ray Interaction with Matter

Gamma Radiation Absorption Characteristics of Concrete with Components of Different Type Materials

Rad T 290 Worksheet 2

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

Study on Mass Attenuation Coefficients and Optical Properties for Boro-Tellurite Glass doped with Barium

Shell Atomic Model and Energy Levels

Volume 1 No. 4, October 2011 ISSN International Journal of Science and Technology IJST Journal. All rights reserved

Gamma-ray shielding of concretes including magnetite in different rate

Interactions of Photons with Matter Compton Scatter (Part 2)

CALCULATION OF GAMMA-RAY ATTENUATION PARAMETERS FOR LOCALLY DEVELOPED ILMENITE-MAGNETITE CONCRETE

DETERMINATION OF TOTAL MASS ATTENUATION COEFFICIENTS, EFFECTIVE ATOMIC NUMBERS AND EFFECTIVE ELECTRON DENSITY FOR THE MARTIAN ATMOSPHERE

CHAPTER 2 RADIATION INTERACTIONS WITH MATTER HDR 112 RADIATION BIOLOGY AND RADIATION PROTECTION MR KAMARUL AMIN BIN ABDULLAH

Fluence-to-Dose Conversion Coefficients for Muons and Pions Calculated Based on ICRP Publication 103 Using the PHITS Code

Journal of Chemical and Pharmaceutical Research, 2012, 4(1): Research Article

Chapter 2: Interactions of Radiation with Matter

Ranges of Electrons for Human Body Substances

INTERACTIONS OF RADIATION WITH MATTER

Quantities and Units for Use in Radiation Protection

Electron density and effective atomic number images generated by dual energy imaging with a 320-detector CT system: A feasibility study

STANDARD WATER PHANTOM BACKSCATTER FACTORS FOR MEDIUM ENERGY X-RAYS

CHAPTER 4 RADIATION ATTENUATION

Gy can be used for any type of radiation. Gy does not describe the biological effects of the different radiations.

Radiation Dose, Biology & Risk

Calculation of the Stopping Power for Intermediate Energy Positrons. Önder Kabaday, and M. Çaǧatay Tufan

Imperfections (Defects)

Atoms, Radiation, and Radiation Protection

A small object is placed a distance 2.0 cm from a thin convex lens. The focal length of the lens is 5.0 cm.

Akira Endo ICRP Committee 2 & ICRU Report Committee 26 Japan Atomic Energy Agency

CHARACTERIZATION OF A RADIATION DETECTOR FOR AIRCRAFT MEASUREMENTS

Journal of Chemical and Pharmaceutical Research

X-ray induced singlet oxygen generation by. nanoparticle-photosensitizer conjugates for. photodynamic therapy: determination of singlet

GLOSSARY OF BASIC RADIATION PROTECTION TERMINOLOGY

Research Article Study of Gamma Ray Exposure Buildup Factor for Some Ceramics with Photon Energy, Penetration Depth and Chemical Composition

Ionizing Radiation Dosimetry and Medical Physics

Evaluation of Phantom Equivalent Materials in Polychromatic Diagnostic X-Ray Beam

Radiation Dosimetry. Electron interactions with matter. Important processes in radiotherapy. Contents. Alun Beddoe

Attenuation Coefficient of Soil Samples by Gamma ray Energy

Determination of the tissue attenuation factor along two major axes of a high dose rate HDR 192 Ir source

Thermoluminescence Properties of Local Feldspar from Gattar Mountain Area

Radiation Quantities and Units

Secondary Neutron Dose Measurement for Proton Line Scanning Therapy

Neutron interactions and dosimetry. Eirik Malinen Einar Waldeland

TITLE: Air Kerma Primary Standard: Experimental and Simulation Studies on Cs-137

Physics of Radiotherapy. Lecture II: Interaction of Ionizing Radiation With Matter

Bases of radioisotope diagnostic methods

Determining photon energy absorption parameters for different soil samples

Interaction of 662 kev Gamma-rays with Bismuth-based Glass Matrices

Iranian Journal of Medical Physics

Comparative Analysis of Nuclear Cross Sections in Monte Carlo Methods for Medical Physics Applications

A quantitative kinetic model for Al 2 O 3 :C: TL response to UV-illumination

LECTURE 4 PRINCIPLE OF IMAGE FORMATION KAMARUL AMIN BIN ABDULLAH

For the next several lectures, we will be looking at specific photon interactions with matter. In today s lecture, we begin with the photoelectric

Chapter 2 Induction of Thermoluminescence

PERSPECTIVES OF PERSONNEL EXTERNAL DOSIMETRY AT STANFORD LINEAR ACCELERATOR CENTER

CONSIDERATION ON THE H p(10) AND H*(10) SECONDARY STANDARD CHAMBER CHARACTERISTICS

Interactions with Matter Photons, Electrons and Neutrons

Online Publication Date: 15 th May, 2012 Publisher: Asian Economic and Social Society

1Meherun Nahar, Sazzad, 3Abdus Sattar Mollah and 4Mir Mohammad Akramuzzaman Correspondence Address INTRODUCTION MATERIALS AND METHODS Mathematical

INTERNAL RADIATION DOSIMETRY

ATTENUATION STUDIES ON DRY AND HYDRATED CROSS-LINKED HYDROPHILIC COPOLYMER MATERIALS AT 8.02 TO kev USING X-RAY FLUORESCENT SOURCES

Chapter 2 Dose Quantities and Units for Radiation Protection

PHYS 3650L - Modern Physics Laboratory

Monte Carlo study of medium-energy electron penetration in aluminium and silver

Scholars Research Library. Gamma Ray Photon Interaction Studies of Cu in the Energy Range 10keV to 1500keV

Physics of Radiography

Initial Certification

Introduction. Neutron Effects NSEU. Neutron Testing Basics User Requirements Conclusions

Interactions of Particulate Radiation with Matter. Purpose. Importance of particulate interactions

Calibration of a pencil ionization chamber with and without preamplifier

Transcription:

American Journal of Physics and Applications 2014; 2(6): 145-149 Published online December 16, 2014 (http://www.sciencepublishinggroup.com/j/ajpa) doi: 10.11648/j.ajpa.20140206.15 ISSN: 2330-4286 (Print); ISSN: 2330-4308 (Online) Comparison of some human tissues and some commonly used thermoluminescent dosimeters for photon energy absorption Adem Un 1, *, Mümine Un 2, Ibrahim Han 1 1 Department of Physics, Faculty of Arts and Sciences, University of Ağrı Ibrahim Çeçen, 04100 Ağrı, Turkey 2 Institute of Science, University of Ağrı Ibrahim Çeçen, 04100 Ağrı, Turkey Email address: ademun25@yahoo.com (A. Un) To cite this article: Adem Un, Mümine Un, Ibrahim Han. Comparison of Some Human Tissues and Some Commonly Used Thermoluminescent Dosimeters for Photon Energy Absorption. American Journal of Physics and Applications. Vol. 2, No. 6, 2014, pp. 145-149. doi: 10.11648/j.ajpa.20140206.15 Abstract: Mass energy absorption coefficients and effective atomic numbers for photon energy absorption, Z PEAeff have been calculated in the energy range from 1 kev to 20 MeV for human tissues, Adipose Tissue, Blood Whole, Bone Cortical, Brain Grey/White Matter, Breast Tissue, Eye Lens, Lung Tissue, Muscle Skeletal, Ovary, Testis, Soft Tissue. Mass energy absorption coefficients and effective atomic numbers for photon energy absorption have also been calculated for commonly used thermoluminescent dosimeters,tld, in the energy range from 1 kev to 20 MeV. The energy dependence of the mass energy absorption of human tissues and TL dosimeters are shown graphically. The tissue equivalency of TLDs is investigated. The effects of the elemental composition on effective atomic numbers for photon energy absorption and the tissue equivalency of TLDs are discussed. Keywords: Effective Atomic Number, Human Tsissue, Thermoluminescent Dosimeters, Photon Energy Absorption 1. Introduction The mass attenuation coefficient,, is a measure of the probability per unit path length for interactions between the incident photon and the matter. The mass energy absorption coefficient related with the energy-deposition, is a measure of the average fractional amount of incident photon energy transferred to the kinetic energy of charged particles as a result of the interactions of less bremsstrahlung and other escaping secondary photons. This imparted, charged particles kinetic energy, is in turn, a more or less valid approximation of the amount of the photon energy made available for the production of chemical, biological and other effects associated with exposure to ionising radiation. The values of, for medical and health physics are known to be essential quantities in calculating of the penetration and absorbed dose of energetic photons in biological and other materials [1-3]. The commonly used effective atomic number, labeled as Z eff, is determined by using mass attenuation coefficients,, which is a convenient parameter for representing photon interaction. Some studies to determine the Z eff values of composite materials various alloys [4,5], solutions and amino acids [6], some biological materials [7, 8], soils and boron ores [9,10], some dosimetric interest [11] have been reported in the literature. A more useful effective atomic number, labeled as Z PEAeff in this work, is determined by using mass energy absorption coefficients,, which is a convenient parameter in dosimetry as discussed above. Some studies to determine the Z PEAeff values of composite materials such as thermoluminescent (TL) dosimetric compounds [12], dosimetric intereset [13] and some biological molecules [14] have also been reported in the literature. In this study, the direct method is used for determination of effective atomic numbers of human tissues and TL dosimeters. Elemental content of human tissues studied Adipose tissue, Blood-Whole, Cortical Bone, Brain- Grey/White Matter, Breast Tissue, Eye Lens, Lung Tissue, Muscle-Skeletal, Ovary, Testis, Tissue Soft and Tissue Soft- Four Component are taken from the ICRU Report 44 [15]. Since one of the most significant properties of the TL dosimetry materials is the tissue equivalence in the field of

146 Adem Un et al.: Comparison of Some Human Tissues and Some Commonly Used Thermoluminescent Dosimeters for Photon Energy Absorption medical and radiation physics, determination of effective atomic number of human tissues and dosimeters is crucial. In an earlier study, effective atomic numbers of some pure thermoluminescent dosimetric compounds have been calculated with the interpolation method [11]. However, it is well known that a pure material does not exhibit TL properties. Dopants are important components of TL dosimeters as they affect the concentration of the trapping centers in the TL dosimeters and also the energy deposition. The trapping centers are responsible for storing the energy after irradiation [16]. There are no reports regarding the Z PEAeff of the doped TL dosimeter in the literature. Because of this reason, Z PEAeff of some commonly used pure and doped TL dosimeters LiF, TLD-100 (LiF:Mg,Ti) [17], TLD-700 (LiF:Mg,Cu,P-0.18, 0.0024, 2.3 wt %) [16], CaF 2, TLD-400 (CaF 2 :Mn-2.5, 3, 4.3 % mol) [18], BaSO 4, BaSO 4 :Eu,Dy (2, 2 mol %) [19], BaSO 4 :Sm (0.5, 1 mol %), BaSO 4 :Eu (0.5, 1 mol %), BaSO 4 :Dy (0.5, 1 mol %) and BaSO 4 : Tm (0.5, 1 mol %) [20], CaSO 4, CaSO 4 :Dy (0.05 mol %) [21], CaSO 4 :Tm (0.1 mol %) [22] are calculated by using the direct method in this study. The energy dependence of and Z PEAeff of some human tissues and TL dosimeters mentioned above is shown graphically. Z PEAeff values determined are compared each other in the energy range from 1keV to 20 MeV, since photons of energy 5-1500 kev are very important in the radiation biology, especially in diagnostics and therapy [23]. The Z PEAeff values of the human tissues are compared with that of the TL dosimeters for determination of tissue equivalency of TL dosimeters. can be determined by using the equation:, = =! " = # $,, (3) / where " = % % is the fractional abundance of the ith element. The and % % are the number of the atoms of the ith constituent element and the total number of the atoms in the studied material, respectively. Effective electronic energy absorption cross section,,, can be calculated by:, =! & ' = # (, ' )*++, (4) where, is the atomic number of the ith constituent element. And, the effective atomic number for photon energy absorption, Z PEAeff, can be given as: 3. Results and Discussion, -.&& = # (, #,. (5) The energy dependence of mass energy absorption coefficients,, are shown in Fig. 1 and 2 for the human tissues and some commonly used TL dosimeters. Three energy range photoelectric absorption, Compton scattering and pair production are clearly seen from the diagrams. While the photoelectric absorption is the dominant process at low energy region, Compton scattering and pair production are the dominant process at medium energies and high energies, respectively [1]. 2. Calculating of the Effective Atomic Number The effective atomic number for photon energy absorption, Z PEAeff, can be determined from the mass energy absorption coefficient,, which has been calculated for composite materials by the additivity law [3] = ( ), (1) where and ( ) are the weight fraction and the mass energy absorption coefficients of the ith constituent element, respectively. The( ) values of the ith constituent element have been taken from the compilation of Hubbel and Seltzer, [2]. The total molecular energy absorption cross section,,, were then determined from the values with the following relation, =, (2) where = is the molecular weight of the studied material, is the Avogadro number, is the total number of atoms in the molecule, and is the atomic weight of the ith constituent element. The effective atomic energy absorption cross section,,, Fig. 1. The energy dependence of the mass energy absorption coefficient,, of human tissues. For the determination of tissue equivalence of TL dosimeters, the values of Z PEAeff of the TL dosimeters are also determined and compared in the energy range from 1 kev to 20 MeV with that of the tissues studied in this work. The explanation of the variation of Z PEAeff with photon energy for TL dosimeters is the same with the case for the human tissues mentioned above. It can be seen from Figs. 3-8 that the variation of Z PEAeff with energy is similar for the TL dosimeters and soft tissues except for BaSO 4 doped with the Sm, Eu, Dy and Tm having high atomic numbers because of the abrupt changes near the absorption edges.

American Journal of Physics and Applications 2014; 2(6): 145-149 147 Fig. 2. The energy dependence of the mass energy absorption coefficient,, of some commonly used thermoluminescent dosimeters. Fig. 4. The comparison of Z PEAeff values of LiF, TLD-100 and TLD-700 with Z PEAeff values of Adipose Tissue, Cortical Bone, Breast Tissue, Eye lens and Soft Tissue. Fig. 3. The energy dependence of Z PEAeff of human tissues. Fig. 5. The comparison of Z PEAeff values of CaF 2 and CaF 2:Mn (2.5, 3.0 and 4.3 % mol) with Z PEAeff values of Adipose Tissue, Cortical Bone, Breast Tissue, Eye lens and Soft Tissue.

148 Adem Un et al.: Comparison of Some Human Tissues and Some Commonly Used Thermoluminescent Dosimeters for Photon Energy Absorption The maximum values of Z PEAeff are 8.903 for TLD 100 and 9.346 for TLD 700 at energy 15 kev, 18.473 for CaF 2 :Mn (2.5 % mol), 18.580 for CaF 2 :Mn (3 % mol) and 18.852 for CaF 2 :Mn (4.3 % mol) at energy 40 kev, 17.026 for CaSO 4 :Tm (0.1 mol %) at energy 40 kev, 48.780 for BaSO 4 :Eu,Dy (2, 2 mol %) at energy 60 kev, 46.466 and 46.798 for BaSO 4 :Sm (0.5 and 1 mol %) at energy 60 kev, 46.482 and 46.828 for BaSO 4 :Eu (0.5 and 1 mol %) at energy 60 kev, 46.501 and 46.869 BaSO 4 :Dy (0.5 and 1 mol %) at energy 60 kev, 46.508 and 46.884 fo BaSO 4 :Tm (0.5 and 1 mol %) at energy 60 kev, respectively. It can be seen in Fig. 4 that the values of Z PEAeff for LiF, TLD 100 and TLD 700 are approximately same with that of the Cortical Bone in the energy range from 200 kev to 5MeV. Therefore, LiF, TLD 100 and TLD 700 can be used as tissue equivalent materials for Cortical Bone in that energy range. Because of their elemental compositions, pure and doped BaSO 4 dosimeters cannot be used as tissue equivalent materials for the studied human tissues in energy range 1keV- 20 MeV as seen in Fig.7 and Fig.8. Fig. 6. The comparison of Z PEAeff values of CaSO 4 and CaSO 4:Tm (0.1 % mol) with Z PEAeff values of Adipose Tissue, Cortical Bone, Breast Tissue, Eye lens and Soft Tissue. Fig. 7. The comparison of Z PEAeff values of BaSO 4 and BaSO 4:Eu,Dy (2, 2 mol %) with Z PEAeff values of Adipose Tissue, Cortical Bone, Breast Tissue, Eye lens and Soft Tissue. While the CaF 2 and CaF 2 :Mn (2.5 % mol) can be used as equivalent material for Cortical Bone in the energy range from 3 kev to 4 kev, CaSO 4 and CaSO 4 :Tm (0.1 mol %) can be used as equivalent material for Cortical Bone in the energy range from 5 kev to 40 kev as can be seen in Fig.5 and Fig.6, respectively. Fig. 8. The comparison of Z PEAeff values of BaSO 4, BaSO 4:Sm (0.5 and 1 mol %), BaSO 4:Eu (0.5 and 1 mol %), BaSO 4:Dy (0.5 and 1 mol %) and BaSO 4:Tm (0.5 and 1 mol %) with Z PEAeff values of Adipose Tissue, Cortical Bone, Breast Tissue, Eye lens and Soft Tissue. 4. Conclusions Knowledge of the tissue equivalence of TL dosimeters is very important in terms of energy absorption. In this study, the effective atomic number for the mass energy absorption, Z PEAeff and the mass energy absorption coefficients,,

American Journal of Physics and Applications 2014; 2(6): 145-149 149 for human tissues and some commonly used TL dosimeters are calculated for the examination of tissue equivalence of dosimeters. Because of the high concentration of Ca, Z PEAeff value of Cortical Bone is larger than that of the other human tissues in the all energy region. LiF, TLD 100 and TLD 700 are determined in the energy range from 200 kev to 5MeV; CaF 2 and CaF 2 :Mn (2.5 % mol) are determined in the energy range from 3 kev to 4 kev; and CaSO 4 and CaSO 4 :Tm (0.1 mol %) are determined in the energy range from 5 kev to 40 kev as tissue equivalent materials for Cortical Bone. Acknowledgment The authors would like to thanks to Scientific Research Projects Office of Ağrı İbrahim Çeçen University through the Grant FEF.12.003 for financial supports. References [1] J. H. Hubbell, Photon mass attenuation and energy absorption coefficients from 1 kev to 20 MeV Int. J. Appl. Radiat. Isot. Vol. 33, pp. 1269 1290, 1982. [2] J. H. Hubbell and S. M. Seltzer, Tables of x-ray mass attenuation coefficients and mass energy absorption coefficients 1 kev to 20 MeV for elements Z=1 to 92 and 48 additional substances of dosimetric interest NISTIR 5632, 1995. [3] Shivaramu and V. Ramprasath, Effective atomic numbers for photon energy absorption and energy dependence of some thermoluminescent dosimetric compounds Nucl. Instrum. Methods Phys. Res. B vol. 168, pp. 294-304, 2000. [4] I. Han and L. Demir, Mass attenuation coefficients, effective atomic and electron numbers of Ti and Ni alloys Radiat. Meas. Vol. 44, pp. 289, 2009. [5] V. R. K. Murty, D. P. Winkoun and K. R. S. Devan, Effective atomic numbers for W/Cu alloy using transmission experiments Appl. Radiat. Isot. Vol. 53, pp.945-948, 2000. [6] S. R. Manohara and S. M. Hanagodimath, Studies on effective atomic numbers and electron densities of essential amino acids in the energy range 1 kev 100 GeV Nucl. Instrum. Methods Phys. Res. B vol. 258, pp. 321, 2007. [7] M. Rao, Interaction of low energy photons with biological materials and effective atomic numbers Med. Phys. vol. 12, pp. 745 748, 1985. [8] S. R. Manohara, S. M. Hanagodimath, K. S. Thind, L. Gerward, The effective atomic number revisited in the light of modern photon-interaction cross-section databases Appl. Radiat. Isot. vol. 68, pp. 784 787, 2010. [9] A. Un and Y. Sahin, Determination of mass attenuation coefficients, effective atomic and electron numbers, mean free paths and kermas for PbO, barite and some boron ores Nucl. Instrum. Methods Phys. Res. B vol. 269, pp. 1506, 2011. [10] A. Un and Y. Sahin, Determination of mass attenuation coefficients, effective atomic numbers, effective electron numbers and kermas for Earth and Martian soils Nucl. Instrum. Methods Phys. Res. B vol. 288, pp. 42-47, 2012. [11] Shivaramua, R. Vijayakumar, L. Rajasekaranb and N. Ramamurthyb, Effective atomic numbers for photon energy absorption of some low-z substances of dosimetric interest Radiat. Phys. Chem. Vol. 62, pp. 371 377, 2001. [12] Shivaramu, Effective atomic numbers for photon energy absorption and photon attenuation of tissues from human organs Med. Dosim. Vol.27, pp. 1 9, 2002. [13] T. K. Kumar and K.V. Reddy, Effective atomic numbers for materials of dosimetric interest Radiat. Phys. Chem. Vol. 50, pp. 545 553, 1997. [14] S. R. Manohara and S. M. Hanagodimath, Effective atomic numbers for photon energy absorption of essential amino acids in the energy range 1 kev 20 MeV Nucl. Instrum. Methods, B vol. 264, pp. 9, 2007. [15] ICRU, Report No 44 Tissue substitutes in radiation dosimetry and measurement (International Commission of Radiation Units and Measurements, Bethesda, MD), 1989. [16] P. N. Mobit, A. E. Nahum and P. Maylesz, Monte Carlo study of the quality dependence factors of common TLD materials in photon and electron beams Phys. Med. Biol. Vol. 43, pp.2015 2032, 1998. [17] C. Furetta, Handbook of Thermoluminescence, World Scientific Publishing co.pte. Ltd., Singapure, 2003. [18] M. Danilkin, A. Lust, M. Kerikmäe, V. Seeman, H. Mändar and M. Must, CaF2:Mn extreme dosimeter: Effects of Mn concentration on thermoluminescence mechanisms and properties Radiat. Measur. Vol. 41, pp. 677 681, 2006. [19] Y. R. Devi and S. D. Singh, Synthesis and TL glow curve analysis of BaSO :Eu,Dy phosphor J. Lumin. Vol. 132, pp. 1575 1580, 2012. [20] P. R. Gonzalez, C. Furetta, B. E. Calvo, M. I. Gaso and E. Cruz-Zaragoza, Dosimetric characterization of a new preparation of BaSO4 activated by Eu ions Nucl. Instrum. Methods, B vol. 260, pp. 685 692, 2007. [21] S. S. Shinde, T. K. Gundu Rao, S.S. Sanaye and B.C. Bhatt, Tl and esr characteristics of baso4:eu co-doped with na/p: influence of method of preparation Radiat. Prot. Dosim. Vol. 84, pp. 215 218, 1999. [22] K. Shinsho, Watanabe, E. and Urushiyama, A., Elucidation of the annealing process required in the preparation of the thermoluminescence phosphor of CaSO4 :Tm, J. Appl. Phys. vol. 100, pp. 093514, 2006. [23] J. H. Hubbell, Review of photon interaction cross section data in medical and biological context Phys. Med. Biol. Vol. 44, pp. R1 R22, 1999.