EXPERIMENTAL STUDY ON EVAPORATION OF A MOVING LIQUID PLUG INSIDE A HEATED DRY CAPILLARY TUBE

Similar documents
THERMO-HYDRODYNAMICS OF TAYLOR BUBBLE FLOW IN CONTEXT OF PULSATING HEAT PIPE: A REVIEW

LIQUID FILM THICKNESS OF OSCILLATING FLOW IN A MICRO TUBE

THE EFFECT OF LIQUID FILM EVAPORATION ON FLOW BOILING HEAT TRANSFER IN A MICRO TUBE

23(5$7,21$/&+$5$&7(5,67,&62))/$73/$7( &/26('/22338/6$7,1*+($73,3(6

IHTC DRAFT MEASUREMENT OF LIQUID FILM THICKNESS IN MICRO TUBE ANNULAR FLOW

The Effect of Bubble Acceleration on the Liquid Film Thickness in Micro Tubes

Measurement of the Liquid Film Thickness in. Micro Tube Slug Flow

NUMERICAL INVESTIGATION OF THERMOCAPILLARY INDUCED MOTION OF A LIQUID SLUG IN A CAPILLARY TUBE

Multiphase Flow and Heat Transfer

KEYNOTE PAPER LIQUID FILM THICKNESS IN MICRO CHANNEL SLUG FLOW

Fluid Flow, Heat Transfer and Boiling in Micro-Channels

Performance Analysis of Pulsating Heat Pipes Using Various Fluids

Mathematical Modelling for Refrigerant Flow in Diabatic Capillary Tube

Boiling and Condensation (ME742)

AN EXPLORATORY STUDY OF A PULSATING HEAT PIPE OPERATED WITH A TWO COMPONENT FLUID MIXTURE

Experimental Analysis of Wire Sandwiched Micro Heat Pipes

Interfacial Flows of Contact Line Dynamics and Liquid Displacement in a Circular Microchannel

Enhanced Boiling Heat Transfer by using micropin-finned surfaces for Electronic Cooling

FLOW BOILING HEAT-TRANSFER IN PLATE MICRO- CHANNEL HEAT SINK

Thermal Performance Characterization of Embedded Pulsating Heat Pipe Radiators by Infrared Thermography

Transient pressure drop correlation between parallel minichannels during flow boiling of R134a

Solid to liquid. Liquid to gas. Gas to solid. Liquid to solid. Gas to liquid. +energy. -energy

LOCAL THERMO-HYDRODYNAMICS OF A LIQUID PLUG PULSATING INSIDE A DRY CAPILLARY TUBE

SOLIDS AND LIQUIDS - Here's a brief review of the atomic picture or gases, liquids, and solids GASES

InterPACKICNMM

EXPERIMENTAL INVESTIGATION OF IN SITU PRESSURE MEASUREMENT OF AN OSCILLATING HEAT PIPE

Influence of Heat Input, Working Fluid and Evacuation Level on the Performance of Pulsating Heat Pipe

THE INDIAN COMMUNITY SCHOOL,KUWAIT PHYSICS SECTION-A

Available online at ScienceDirect. Physics Procedia 67 (2015 ) Superfluid helium heat pipe. P.

High Resolution Measurements of Boiling Heat Transfer

Numerical Simulation on Flow and Heat Transfer in Oscillating Heat Pipes

EXPERIMENT No.1 FLOW MEASUREMENT BY ORIFICEMETER

HEAT TRANSFER CAPABILITY OF A THERMOSYPHON HEAT TRANSPORT DEVICE WITH EXPERIMENTAL AND CFD STUDIES

10.52 Mechanics of Fluids Spring 2006 Problem Set 3

Experimental Study on Liquid Film Thickness of Annular Flow in Microchannels

Evaporation Heat Transfer Coefficients Of R-446A And R-1234ze(E)

Chapter 10: Boiling and Condensation 1. Based on lecture by Yoav Peles, Mech. Aero. Nuc. Eng., RPI.

EFFECT OF LIQUID REYNOLDS NUMBER ON PRESSURE DROP OF EVAPORATIVE R-290 IN 500µm CIRCULAR TUBE

Forced Convection: Inside Pipe HANNA ILYANI ZULHAIMI

EXPERIMENTAL ANALYSIS OF R-134a FLOW CONDENSATION IN A SMOOTH TUBE

FLAT PLATE HEAT PIPES: FROM OBSERVATIONS TO THE MODELING OF THE CAPILLARY STRUCTURE

Measurement of Liquid Film Thickness in Micro Square Channel

Capillarity of Rectangular Micro Grooves and Their Application to Heat Pipes

Measurement of Conductivity of Liquids

Experimental and Theoretical Evaluation of the Overall Heat Loss Coefficient of a Vacuum Tube Solar Collector

An insight into thermo-hydrodynamic coupling in closed loop pulsating heat pipes

Measuring Viscosity. Advanced Higher Physics Investigation. Jakub Srsen SCN: Boroughmuir High School Center Number:

Condensation and Evaporation Characteristics of Flows Inside Three Dimensional Vipertex Enhanced Heat Transfer Tubes

Analysis of chaotic flow in a 2D multi-turn closed-loop pulsating heat pipe

Correlation to predict heat transfer of an oscillating loop heat pipe consisting of three interconnected columns

DETERMINATION OF R134A S CONVECTIVE HEAT TRANSFER COEFFICIENT IN HORIZONTAL EVAPORATORS HAVING SMOOTH AND CORRUGATED TUBES

Solar Flat Plate Thermal Collector

Comparison of pool boiling heat transfer for different tunnel-pore surfaces

Q1 Give answers to all of the following questions (5 marks each):

Heat transfer coefficient of near boiling single phase flow with propane in horizontal circular micro channel

M. R. Gartia Reactor Engineering Division Bhabha Atomic Research Centre, Trombay Mumbai P. K. Vijayan.

The effects of gravity on the capillary instability in tubes

Pool Boiling Heat Transfer to Pure Liquids

Experimental investigation on up-flow boiling of R1234yf in aluminum multi-port extruded tubes

Onset of Flow Instability in a Rectangular Channel Under Transversely Uniform and Non-uniform Heating

Heat transfer from in-line tube bundles to downward aqueous foam flow

ME 309 Fluid Mechanics Fall 2010 Exam 2 1A. 1B.

Steady and Transient Heat Transfer Characteristics of Flat Micro Heatpipe

Measurement of the performances of a transparent closed loop two-phase thermosyphon

SOLIDS AND LIQUIDS - Here's a brief review of the atomic picture or gases, liquids, and solids GASES

Differential Mobility Particle Sizer (Aerosol measurements)

International Journal of Thermal Sciences

Uncertainty Analysis of Flat Plate Oscillating Heat Pipe with different Working Fluids

A generalized correlation of nucleate pool boiling of liquids

CENG 501 Examination Problem: Estimation of Viscosity with a Falling - Cylinder Viscometer

Experimental Study of Convective Heat Transfer and Thermal Performance in the Heat-Sink Channel with Various Geometrical Configurations Fins

IDENTIFICATION OF FLOW BOILING PATTERNS IN MINICHANNEL WITH THE USE OF ANALYSIS OF PRESSURE OSCILLATIONS

Contents. Microfluidics - Jens Ducrée Physics: Laminar and Turbulent Flow 1

EMBEDDED PULSATING HEAT PIPE RADIATORS

Mechanism of atomization in a two-layer Couette flow

Capillarity and Wetting Phenomena

Biological Process Engineering An Analogical Approach to Fluid Flow, Heat Transfer, and Mass Transfer Applied to Biological Systems

Petroleum Engineering Dept. Fluid Mechanics Second Stage Dr. Ahmed K. Alshara

APPLICATION OF THE COUPLED THREE DIMENSIONAL THERMAL- HYDRAULICS AND NEUTRON KINETICS MODELS TO PWR STEAM LINE BREAK ANALYSIS

A Fundamental Study on High Heat Flux Cooling using Subcooled Flow Boiling with Microbubble Emission

Water Circuit Lab. The pressure drop along a straight pipe segment can be calculated using the following set of equations:

Proceedings of 12th International Heat Pipe Conference, pp , Moscow, Russia, 2002.

CFD Simulation of Sodium Boiling in Heated Pipe using RPI Model

Particles Removal from a Moving Tube by Blowing Systems: A CFD Analysis

- As for the liquids, the properties of different solids often differ considerably. Compare a sample of candle wax to a sample of quartz.

Experimental Study of Flow Characteristic at Horizontal Mini Channel

(Refer Slide Time: 02:18)

Tutorial 1. Where Nu=(hl/k); Reynolds number Re=(Vlρ/µ) and Prandtl number Pr=(µCp/k)

Analysis of Heat Transfer Enhancement in Spiral Plate Heat Exchanger

On supercooled water drops impacting on superhydrophobic textures

Most substances can be in three states: solid, liquid, and gas.

Comparison of Heat Transfer rate of closed loop micro pulsating heat pipes having different number of turns

Extreme-Microgap (x-μgap) Based Hotspot Thermal Management with Refrigerant Flow Boiling

Effect of Channel Size on Heat Transfer and Pressure Drop in Thin Slabs Minichannel Heat Exchanger

Lectures on Applied Reactor Technology and Nuclear Power Safety. Lecture No 6

GAS LAWS. Boyle s Law: Investigating the dependence of Volume on Pressure (Temperature kept constant)

Experimental Study of Energy Efficiency of a Single Microtube

FACULTY OF CHEMICAL & ENERGY ENGINEERING FLUID MECHANICS LABORATORY TITLE OF EXPERIMENT: MINOR LOSSES IN PIPE (E4)

ICSE Board Class IX Physics Paper 2 Solution

Fluid Mechanics Introduction

Transcription:

EXPERIMENTAL STUDY ON EVAPORATION OF A MOVING LIQUID PLUG INSIDE A HEATED DRY CAPILLARY TUBE Victor Marty-Jourjon a, Vyas Srinivasan b,c,d, Peeyush P. Kulkarni b,c,d, Sameer Khandekar *,b,c,d a INSA-Lyon, F-69621, Villeurbanne, France b Department of Mechanical Engineering c Indian Institute of Technology Kanpur d Kanpur (UP) 208016 India Corresponding author: Tel: +91 512 259 7038, Fax: +91 512 259 7408 Email: samkhan@iitk.ac.in Abstract. The paper reports an experimental study to understand the effect of heat on an isolated liquid plug (methanol) of length L moving inside a long, dry, horizontal circular mini-channel (inside D = 1.5 mm). The plug (with specified range of L/D ratios) is pushed from rest by controlled injection of air from its one side, till a quasi-steady terminal plug velocity is achieved in the adiabatic section of the capillarity tube. It is then allowed to move through the heated section maintained at constant wall temperature. It is evident from the experiments that there is a significant increase of the plug velocity in the heated region, which can be attributed to the evaporation of liquid; this increases as the wall temperature increases. Also, it is observed that evaporation is not primarily from the bulk of liquid plug but from the thin film trailing behind it. Keywords: Taylor liquid plug, Capillary plug flow, thin film evaporation, meniscus motion, terminal velocity, constant wall temperature 1 Introduction The fundamental understanding of two-phase micro-/mini-channel flows (systems with Bo < 2) is one of the critical issues for the development of many emerging technologies. For example, it has been highlighted that such phase-change process in mini/micro systems are effective in passive thermal energy management in pulsating heat pipes, electronic cooling, lab-on-chip, PEM fuel cells etc. [3]. However, comprehensive understanding of such processes is limited, largely due to the simultaneous involvement of several coupled and complex transport issues such as contact line dynamics and its hysteresis, wettability, capillary instabilities, etc. In this background, this adfa, p. 1, 2011. Springer-Verlag Berlin Heidelberg 2011

experimental study makes an attempt to understand the behavior of a single liquid plug of methanol (chosen due to its good volatility and moderate boiling point at atmospheric conditions) in a micro-/minichannel when its motion is subjected to a constant wall temperature. 2 Experimental details and procedure The experiment is conducted with a simple, horizontally placed transparent glass circular capillary tube of 1.5 mm I.D., shown in Fig. 1. As the system is very sensitive to containments, a thorough cleaning and drying procedure (with deionised water, methanol, and dry air) is carried out before each run, to have good reproducibility. A methanol liquid plug of known volume is placed inside the tube at the starting (pre-conditioning) adiabatic section (Fig. 1 (b)) and is forced to move inside the capillary tube by injecting air at known mass flow rate (25 mlph), pumped via a syringe pump, as shown in Fig. 1a. The preconditioning section is long enough to ensure that all methanol plugs reach the heated section with a terminal velocity (Fig. 1 (b)). A large reservoir is connected to the outlet of syringe pump, so as to make the volume of mass injection significantly larger than the volume of circular tube. This is done so that a known mass flow rate of air can be pushed quasi-statically at near constant volume and temperature. Besides, all the experiments were done at controlled ambient conditions. The set up is very sensitive to any variation of temperature. A 0-100 Pa range differential pressure transducer (Huba Control ; 699 series) is used to get pressure drop across the liquid plugs, while the high speed images (captured using Photoron SA-3) are post-processed to estimate the change in plug length and its velocity during its passage through the capillary tube. To maintain constant wall temperature, a constant temperature water bath (Julabo - F25) is used. (a) (b) Fig. 1. (a) Schematic of the experimental setup (b) Zoom-in view of the capillary tube highlighting the adiabatic (pre-conditioning) and the diabatic sections.

3 Results and Discussions The experiments are carried out for two different boundary conditions viz., fully adiabatic and diabatic. For both the cases, the variation of pressure, velocity and L/D with time are obtained. (a) Adiabatic behaviour for different L/D As can be seen from Fig. 2(a), the pressure seems to oscillate throughout the movement of the plug through the capillary. These oscillations can be attributed to the irregularities/contact line pinning on the inner capillary wall. Local pinning of three-phase contact line cannot be completely eliminated. It can be clearly observed that the pressure is almost independent of the liquid plug length and is due to surface forces dominance; this is in accordance with the observations made by Srinivasan et al. [4] which highlight the dominance of surface tension forces in contributing towards overall friction, as compared to viscous wall friction. There is only very minor change in the pressure with L/D. This observation is in line with the pressure variation curve where there is some amount of lag between each curve towards the end of the recording. As the plug moves through the capillary tube its velocity intermittently varies. As noted earlier, these velocity estimates were made with the help of video recordings and their subsequent image processing. The velocity plot (Fig. 2(b)) for a good extent, is inline with the pressure variation (Fig. 2(a)). As can be seen, the velocity decreases just before an irregularity/pinning sets in due to an increase in friction, at the same time the pushing pressure increases. (a) (b) Fig. 2. (a) Pressure variation with time for different length of methanol plug at adiabatic condition. (b) Velocity variation under adiabatic condition. The discontinuity in the graph is due to strong influence of pinning.

Once, the plug has crossed the irregularity, there is a peak of velocity observed and correspondingly a sudden drop of pressure due to a sudden decrease in friction. The gap in the velocity plot around the 50 sec time interval is due to the non-availability of the video recordings because of gasket present at the physical joint. Incidently, in this gap region, the first major irregularity occurs which can be attributed to the roughness of the tube wall, which matches with the first significant rise in pressure (~ between 45 sec to 55 sec) on the pressure plot (Fig. 2(a)). As also seen in the pressure plot, there is an effect of increasing friction on the last peak of velocity where there is a little lag between each curve. When liquid plugs moves through the capillary tube it can be seen that it leaves a thin layer of fluid on the surface, which leads to a decrease of length of the methanol cell (see Fig. 4). The classical papers of Taylor [5] and Bertherton [2] talk extensively on the thin film deposition. A more recent paper by Aussillous and Quere [1] provides new data on the quick deposition of fluid on the wall of a tube. Taylors formula is used by Bretherton [2] to calculate the thin film thickness (Eq. 2) depending of a dynamic Capillary number (Eq. 1), and thus, the theoretical decreasing of length shown in Fig. 3. For each L/D this decreasing of length seems to match well with the experimental data. Fig. 3. Change of length with time due to drainage in form of thin film for different initial L/D ratios at adiabatic condition

Capillary number is defined as: v Ca (1) Once the Capillary number is known, the thickness of trailing thin film is calculated based on Taylor law [5] as: 2 / 3 h 1.34Ca (2) 2 / 3 r 1 1.34(2.5Ca) (b) Behaviour of a single liquid plug at different temperatures The experiment was carried out with the application of constant wall temperature around the capillary tube. Under the effect of imposed boundary conditions there are interesting modifications of the pressure profile along the channel. The variation of pressure for L/D ratio = 6.7, at different wall temperature, is shown in Fig. 4(a). The region of the curve corresponding to around 10 sec to 40 sec represents the adiabatic region, where there is no heat applied and it can be seen that the curves are almost similar. The region where the pressure starts to rise (~45 sec), corresponds to the beginning of the heated section which also matches with region of first mean irregularity. In either cases, for ΔT = 0 (adiabatic case) and T = 55 C, two main peaks can be identified. However, the time interval between the two peaks is not the same for both cases. Indeed, the time interval between the two peaks is approximately 100 sec for the adiabatic case and around 40 sec for wall temperature of 55 C. (a) (b) Fig. 4. (a) Gauge pressure vs. time for L/D = 6.7 at different wall temperatures (b) Variation of velocity with time for L/D = 6.7 at different wall temperature

An important implication of this difference is that the velocity of the methanol plug increases as it travels through the heated section. It is observed that this increase in velocity is higher, as the wall temperature is increased, which is dicernable from the reducing time intervals between the pressure peaks. However, it is difficult to identify the second peak for higher temperatures of 65 C and 70 C for which the plug attains a very large velocity and hence overcomes the irregularities in its path, thereby reducing the pinning tendency. It is interesting to see the global evolution of velocity with time for the liquid plug corresponding to different temperatures. Fig. 4(b) shows the variation of velocity with time. At the beginning of the plug motion which corresponds to the adiabatic section, the velocity variation is same for different temperatures. But as the plug moves into the heater section, there is sudden increase in the velocity. Also, as identified in the pressure variation plot (Fig. 4(a)), the time interval between different velocity peaks for both the adiabatic and T = 55 C cases can be identified clearly. Besides, for all the readings corresponding to different temperatures, the last point on each curve corresponds to the same position in the channel. Thus, the variations of velocity lead to a delay at the end of the channel which is nearly 70 sec and 100 sec for T = 55 C and T = 70 C respectively. For the wall temperature of 70 C, which is above the boiling point of methanol (~65 C) the video recording could not be done at the same position as at this temperature the creation of bubbles in the liquid plug is observed (Fig. 5) because of vigourous nucleate boiling. Fig. 5. Development of nucleation and bubble breakup at wall temperature of 70 C (boiling point of methanol at room conditions = 64.7 C)

The effect of increase of evaporation rate on increase of velocity can be clearly seen for higher wall temperature of T = 65 C. The velocity behaviour is totally different from lower wall temperatures. In fact the velocity does not drop after the irregularity but keeps on increasing further. For the wall temperature of 70 C, the beginning of the profile seems to be similar to the lower temperature readings, however as there is a rapid break-up of the plug so it does not allow the analysis to be carried at same location. As the liquid plug moves through the heated section, its length decreases, the rate of decrease being higher temperatures. This change in length is plotted as function of time in Fig. 6. Except for T = 70 C, the experimental values are compared with the values obtained by the Taylor's Law [5]. To calculate the values from Taylor's law, thermophysical characteristics of methanol were taken at 33 C, 55 C and 65 C, assuming that the liquid plug temperature reaches these values instantly. It can be seen that the experimental values match with the Taylor's Law values to a reasonable extent. It can be concluded that the decrease of plug length is because of evaporation via the film drainage route. In other words, evaporation rate from the bulk liquid plug is too small to affect the decrease of length of the liquid plug; the evaporation mainly occurs in the thin trailing film left behind the liquid plug. However, the wall temperature has an indirect significant effect on the reduced plug length as it affects the velocity, which in turn, affects the drainage. Fig. 6. Change in length of liquid plug (initial L/D = 6.7) with time for different wall temperatures.

4 SUMMARY AND CONCLUSIONS Experiments were carried out to understand the hydrodynamics of a single liquid (methanol) plug inside a horizontal, dry, mini/micro circular tube. A single liquid plug of known L/D ratio is pushed from rest by controlled injection of air. The drainage of liquid film left behind was compared with the model of Aussillous and Quere [1]. It is demonstrated that under adiabatic conditions, the experimental data of change in length match with the theoretical predictions of Taylor. Also, it can be clearly observed that the pressure is almost independent of the liquid plug length, due to surface forces dominance which is in accordance with the observations made by Srinivasan. et al. [4]. The experiments imposing a constant wall temperature highlight that there is no significant direct effect of the evaporation rate on the decreasing of plug length. Indeed the experimental data still match with the Taylor s law which does not take into account evaporation rate. However, the velocity of the plug is markedly affected by the wall temperature, resulting in significant modification of the drainage rate visible in the Taylor s law. Finally, results show a very important indirect influence of the evaporation on the decreasing plug length. Thus, this evaporation seems to occur mainly in the drained thin film. Future, work involves scrutinizing the current finding and to study the effect of heat for different lengths of liquid plug and using different liquid. 5 References 1. Aussillous, P., and Quéré, D. (2000) Quick Deposition of a Fluid on the Wall of a Tube. Physics of Fluids 12:2367-2371. 2. Bretherton FP (1961) The Motion of Long Bubbles in Tubes. Journal of Fluid Mechanics 10:166-188. 3. Khandekar S, Panigrahi PK, Lefevre F, Bonjour J (2010) Local Hydrodynamics of Flow in a Pulsating Heat Pipe: a Review. Front. Heat Pipes 1:023003. 4. Srinivasan V. And Khandekar S. (2013) Motion of an Isolated Liquid Plug inside a Dry Circular Capillary. Proc. of 17 th International Heat Pipe Conference (17 th IHPC), India 5. Taylor G. (1961) Deposition of a Viscous Fluid on the Wall of a Tube. Journal of Fluid Mechanics 10:161.