Swamp Optics Tutorial. Pulse Compression

Similar documents
Dispersion and how to control it

The spectrogram in acoustics

Describing first-order spatio-temporal distortions in ultrashort pulses using normalized parameters

PROCEEDINGS OF SPIE. Advanced laboratory exercise: studying the dispersion properties of a prism pair

Extreme pulse-front tilt from an etalon

Evolution of the frequency chirp of Gaussian pulses and beams when passing through a pulse compressor

Strongly enhanced negative dispersion from thermal lensing or other focusing effects in femtosecond laser cavities

Novel method for ultrashort laser pulse-width measurement based on the self-diffraction effect

1 Mathematical description of ultrashort laser pulses

APPLICATION NOTE. Supercontinuum Generation in SCG-800 Photonic Crystal Fiber. Technology and Applications Center Newport Corporation

LAB 10: OPTICAL MATERIALS AND DISPERSION I

Assessment of Threshold for Nonlinear Effects in Ibsen Transmission Gratings

STUDYING ULTRAFAST MOLECULAR DYNAMICS IN PUMP-PROBE EXPERIMENTS WITH FEMTOSECOND LASERS JOSEPH HARRINGTON, DR. ARTEM RUDENKO, AND DR.

37. 3rd order nonlinearities

Edward S. Rogers Sr. Department of Electrical and Computer Engineering. ECE318S Fundamentals of Optics. Final Exam. April 16, 2007.

ECEN 4606, UNDERGRADUATE OPTICS LAB

Astronomical Tools. Optics Telescope Design Optical Telescopes Radio Telescopes Infrared Telescopes X Ray Telescopes Gamma Ray Telescopes

n(λ) = c/v(λ). Figure 1: Dispersion curves for some common optical glass types.

Direct measurement of spectral phase for ultrashort laser pulses

by applying two pairs of confocal cylindrical lenses

: Imaging Systems Laboratory II. Laboratory 6: The Polarization of Light April 16 & 18, 2002

Spectral Fraunhofer regime: time-to-frequency conversion by the action of a single time lens on an optical pulse

37. 3rd order nonlinearities

Lab 10: Spectroscopy & the Hydrogen Atom Phy208 Fall 2008

Fast Light, Slow Light

Multilayer thin-film structures with high spatial dispersion

Let us consider a typical Michelson interferometer, where a broadband source is used for illumination (Fig. 1a).

Plasma Formation and Self-focusing in Continuum Generation

Astronomy 203 practice final examination

Design Considerations for a Variable Angle Absolute Reflectance Accessory For the LAMBDA 950/850/650 UV/Vis/NIR and UV/Vis Spectrophotometers

Richard Miles and Arthur Dogariu. Mechanical and Aerospace Engineering Princeton University, Princeton, NJ 08540, USA

Chapter 6 Light and Telescopes

Lab 5: Spectroscopy & the Hydrogen Atom Phy248 Spring 2009

Designing a Computer Generated Hologram for Testing an Aspheric Surface

Intrinsic beam emittance of laser-accelerated electrons measured by x-ray spectroscopic imaging

Name Final Exam May 1, 2017

No. 9 Experimental study on the chirped structure of the construct the early time spectra. [14;15] The prevailing account of the chirped struct

Optical Spectroscopy of Advanced Materials

Using GRENOUILLE to characterize asymmetric femtosecond pulses undergoing self- and cross-phase modulation in a polarization-maintaining optical fiber

Advanced Optical Communications Prof. R. K. Shevgaonkar Department of Electrical Engineering Indian Institute of Technology, Bombay

Innovation and Development of Study Field. nano.tul.cz

Dispersion Compensation with a Prism-pair

POLARIZATION FUNDAMENTAL OPTICS POLARIZATION STATES 1. CARTESIAN REPRESENTATION 2. CIRCULAR REPRESENTATION. Polarization. marketplace.idexop.

Efficient Broadband Second-Harmonic Generation by Dispersive Achromatic Nonlinear Conversion Using Only Prisms

FIBER OPTICS. Prof. R.K. Shevgaonkar. Department of Electrical Engineering. Indian Institute of Technology, Bombay. Lecture: 17.

Measurments with Michelson interferometers

General Physics II Summer Session 2013 Review Ch - 16, 17, 18

Astronomy. Optics and Telescopes

Protokoll. Grundpraktikum II - Optical Spectroscopy

The structure of laser pulses

Interference. Reminder: Exam 2 and Review quiz, more details on the course website

Fiber Gratings p. 1 Basic Concepts p. 1 Bragg Diffraction p. 2 Photosensitivity p. 3 Fabrication Techniques p. 4 Single-Beam Internal Technique p.

B 2 P 2, which implies that g B should be

>> D-5006 CWDM components for 40 G and 100 G Transceivers

What can laser light do for (or to) me?

Optics Optical Testing and Testing Instrumentation Lab

Linear pulse propagation

Phys 100 Astronomy (Dr. Ilias Fernini) Review Questions for Chapter 5

POLARIZATION OF LIGHT

Optical Telescopes. Telescopes. Refracting/Reflecting Telescopes. Physics 113 Goderya

Polarization of Light and Birefringence of Materials

Lecture 2 - Length Contraction

Measuring the spatiotemporal electric field of ultrashort pulses with high spatial and spectral resolution

EE 119 Homework 2. 4 o

ULTRAFAST COMPONENTS

More Optical Telescopes

Parametric Spatio-Temporal Control of Focusing Laser Pulses

Ultra-narrow-band tunable laserline notch filter

Femtochemistry. Mark D. Ellison Department of Chemistry Wittenberg University Springfield, OH

DISPERSION OF A GLASS PRISM

Constructive vs. destructive interference; Coherent vs. incoherent interference

Optical solitons and its applications

CHARA Meeting 2017 Pasadena, California

Optics. Measuring the line spectra of inert gases and metal vapors using a prism spectrometer. LD Physics Leaflets P

Derivation of the General Propagation Equation

Supplementary Material for In situ frequency gating and beam splitting of vacuum- and extreme-ultraviolet pulses

Module 5 - Dispersion and Dispersion Mitigation

Experiment #4: Optical Spectrometer and the Prism Deviation

Speed of Light in Glass

The general theory of first-order spatio-temporal distortions of Gaussian pulses and beams

Ultrashort Pulse Laser Technology for Processing of Advanced Electronics Materials

Multi-cycle THz pulse generation in poled lithium niobate crystals

Engineering Note. Measuring the Polarization Rotation Angle of a Faraday Rotator Mirror with the Optical Vector Analyzer

Hiromitsu TOMIZAWA XFEL Division /SPring-8

Conceptual Physics. Luis A. Anchordoqui. Department of Physics and Astronomy Lehman College, City University of New York. Lesson VI October 3, 2017

Signal to Noise Comparison of IS-Instruments Ltd High Throughput OEM Spectrometer and a Czerny Turner Instrument. July 2013

MEASUREMENT OF COMPLEX ULTRASHORT LASER PULSES USING FREQUENCY-RESOLVED OPTICAL GATING

Experiment 2: The Speed of Light

UNIT-5 EM WAVES UNIT-6 RAY OPTICS

Answers to questions on exam in laser-based combustion diagnostics on March 10, 2006

PRINCIPLES OF PHYSICAL OPTICS

MEMS Metrology. Prof. Tianhong Cui ME 8254

18. Standing Waves, Beats, and Group Velocity

The Emission Spectra of Light

Effect of cross-phase modulation on supercontinuum generated in microstructured fibers with sub-30 fs pulses

Photonic Simulation Software Tools for Education

Cheapest nuller in the World: Crossed beamsplitter cubes

OPSE FINAL EXAM Fall 2016 YOU MUST SHOW YOUR WORK. ANSWERS THAT ARE NOT JUSTIFIED WILL BE GIVEN ZERO CREDIT.

Experiment 3 1. The Michelson Interferometer and the He- Ne Laser Physics 2150 Experiment No. 3 University of Colorado

Single-Mode Propagation ofmutual Temporal Coherence: Equivalence of Time and Frequency Measurements of Polarization Mode Dispersion

Transcription:

Swamp Optics, LLC. 6300 Powers Ferry Rd. Suite 600-345 Atlanta, GA 30339 +1.404.547.9267 www.swamoptics.com Swamp Optics Tutorial Pulse Compression Recall that different colors propagate at different velocities so that, after passing through the material, different colors experience different delays, a ubiquitous effect called group-delay dispersion (G). For wavelengths less than those used in telecommunications (about 1.5 m), red colors always propagate faster than blue colors and so precede the blue wavelengths in the pulse, and one says that the pulse is positively chirped. Chirped pulses are nearly always undesirable in applications, and their increased length and resulting lower intensity make them even less desirable. Because ultrashort pulses have broad spectra, G is a large effect for them and generally results in significant pulse lengthening after propagation through even a few mm of material. Worse, the effects of G accumulate, and the pulse lengthens more and more and becomes more and more positively chirped as it passes through additional material. It is therefore important to minimize the amount of material through which a pulse propagates. Indeed, when the pulse is in the UV spectral region, even propagation through air can lengthen it significantly. The problem is that, in essentially all applications, the pulse is focused and so must pass through a significant amount of glass in the lens or microscope objective, and this glass cannot be avoided. Simply passing through a microscope objective significantly lengthens the pulse, significantly decreasing the intensity of the pulse at the focus. This reduces the sensitivity in all multi-photon microscopy techniques, and it can also hurt the resolution, too. And it is quite deleterious for most other applications for the same reason. Indeed, one of the world s largest laser companies intentionally sells longer-pulse lasers to the imaging community with less bandwidth to the effect of G. Of course, because the pulses are longer to begin with, images made with such pulses have less sensitivity. Unfortunately, while laser companies could sell lasers with negative chirp, they don t in practice because each user has a different amount of G in his microscope objective and in the beam path from the laser to the sample. Fortunately, this problem can be solved. Ultrafast labs have for years used devices called pulse compressors (see Fig. 1),[1-3] which consist of sequences of four prisms that yield a path for which red colors travel a longer optical path than blue colors, and so have negative G. Specifically, the trick is that the redder colors pass through the thicker regions of the second and third prisms, allowing the bluer colors to catch up with them. Fig. 1. Four-prism pulse compressor. Longer wavelengths (red) traverse more glass than shorter ones (blue), passing through the thicker parts of the second and third prisms. A problem, however, is that, when the average wavelength of the pulse changes, all four prisms must be rotated by precisely the same amount (thick pink arrows). Also, coarse and fine tuning of the G are separate. And coarsetuning the G requires changing the separations between the first two and last two prisms, maintaining them precisely equal (thick purple arrows).

Unfortunately, the pulse compressor is very unwieldy. To vary the G slightly, a prism is moved into or out of the beam (the green arrow). But to vary the G over a larger range, the separations between the first and second prisms and the third and fourth prisms must be varied (the purple arrows) and maintained precisely equal to each other which involves several alignment parameters (knobs to turn). Also, if the input wavelength changes, all four prisms must be rotated by precisely the same amount (the pink arrows), maintaining equal incidence angles for all the prisms. Otherwise the device will involve magnification or demagnification of the beam in one direction (yielding an undesirable elliptical output beam) as well as angular dispersion and the spatio-temporal distortions, spatial chirp and pulse-front tilt. Worse, to obtain the desired amounts of negative G, the prism separations must be quite large, and the device can become quite large (a meter or more larger than the laser itself!). Finally, the device is tricky to align to begin with, and small misalignments can cause the above-mentioned deleterious spatio-temporal distortions in the pulse, which can be difficult to diagnose. Fortunately, it was realized quickly that the device could be simplified to two prisms using a mirror (or better, a roof mirror) after the second one to reflect the beam back through the first two prisms. Two-prism designs (see Fig. 2) simplify the device significantly, but it remains complex, and it requires a very complex mechanical apparatus to maintain the required equal incidence angles of the two prisms, and it is difficult to do so sufficiently to avoid the various distortions mentioned above. Indeed, Swamp Optics GRENOUILLEs and FROGs measure these distortions (in addition to the pulse intensity and phase), and we usually find significant amounts of these distortions in pulses that have emerged from pulse compressors. Fig. 2. Two-prism pulse compressor. This device avoids the need for maintaining equal prism separations (note only one thick purple arrow). Unfortunately, when the average wavelength of the input pulse changes, both prisms must still be rotated by precisely the same amount (thick curved pink arrows). And this design still requires a complex arrangement for coarse and fine-tuning the G. To solve these problems, Swamp Optics has introduced a (patent-pending) single-prism pulse compressor (see Fig. 3), which is much simpler, and, even better, it also solves all of the problems described above.[4] It uses a corner cube and inverts the beam not the prism and so only requires one prism. Indeed, the corner cube inverts the beam between the first and second passes through the prism and also between the third and fourth passes through the prism, precisely as required by a pulse compressor! It only requires varying the prism angle to tune in wavelength (no complex mechanical apparatus needed). Also, all of the above-mentioned distortions automatically cancel out even as it is tuned in wavelength. And because it involves double-passing the corner cube, all beam magnifications and dispersions cancel out. In addition, even if the device is bumped, the output beam does not misalign! And because each path between the prism and corner cube is double-passed, the device is only half as big as two prism designs and one fourth as big as four-prism designs. In all other respects, it is identical to conventional pulse Copyright 2015 Swamp Optics, LLC. 2

compressors and so shares their advantages; for example, all passes through the prism occur near the prism tip to avoid introducing unnecessary additional positive G from the prism itself. Fig. 3. Single-prism pulse compressor. The corner cube inverts the beam so that the second and third passes through the prism occur as if the prism is inverted, as required for a pulse compressor. Also, corner cubes are manufactured extremely precisely, so the beam emerging from it is precisely parallel to that entering it. This and the use of a single prism are the keys to avoiding all of the distortions that twoand four-prism designs introduce into the pulse. Also note that only the one prism angle need be rotated when the input wavelength changes, and only one distance need be changed to tune the G. This simplicity yields a much more accurate, much less distorting, and much less expensive device. Also, it yields no deviation in the beam and so can be inserted into the beam and removed without misaligning the apparatus, and, unlike previous compressors, this lack of beam deviation will be maintained despite angle-tuning the prism for other wavelengths. Finally, it achieves significant amounts of negative G, enough to compensate for even a many-element microscope objective. These features make it ideal for multi-photon imaging systems and essentially all ultrafast-optical applications. Indeed, it requires no alignment, and it has only two knobs, one for the G and another for the pulse center wavelength. Here s more detail on these characteristics: agnification: As the wavelength is tuned by rotation of a prism, each pass through the prism necessarily involves unequal incidence and exit angles. While the one-dimensional magnification through a prism is unity when its incidence and exit angles are equal (i.e., Brewster s angle for an ideal pulse compressor), this is not generally the case. When a prism s incidence angle exceeds its exit angle, some one-dimensional magnification occurs, and when the opposite occurs, demagnification occurs. Thus, away from the ideal equal-incidence-and-exit-angle case, each pass through a prism will always yield some one-dimensional magnification or demagnification in the beam. This problem exists in all prism and grating pulse compressors, and, in conventional compressors, it must be addressed in the alignment procedure and unity magnification must be maintained as well as possible by a complex mechanical apparatus when it is tuned. In our single-prism design, as the wavelength is tuned, the first pass through the prism will introduce, say, some magnification. However, after the beam returns from the corner cube, the beam will retrace its path and experience demagnification by exactly the same amount because the input/output angles are reversed as compared with the first pass. As a result, if i is the magnification after the i th pass through the prism, we will have: 1 1 = = = 1 3 2 4 Copyright 2015 Swamp Optics, LLC. 3

ultiplying all four magnifications together yields the overall magnification of the device, which will always be unity. As a result, our single-prism pulse compressor automatically retains unity magnification as the wavelength is tuned! We measured the magnification of the device by measuring the input and output spatial profiles of the beam on a CC camera. Our measured magnification value was 1.01±.02. Angular dispersion: It is even more important that the output angular dispersion remain zero as the G and/or the wavelength is tuned. Because translating the corner cube to vary the G will not affect any device angles, corner-cube translation (G tuning) need not be considered if the dispersion is zero for one value of G, it will be zero for them all. But the variation of the prism angle with wavelength-tuning could, in principle, cause the output angular dispersion to be nonzero, as it easily can in twoand four-prism pulse compressors. The angular dispersion introduced by a prism depends on which direction the beam propagates through it. It is easy to show that, if the i th prism has dispersion i and magnification in the forward direction (and 1/ in the backward direction), it has dispersion in the reverse direction. Thus, the angular dispersion added on each pass through the prism is: 1 22 3 44 where the minus signs take into account the beam flips. The total dispersion of a four-prism sequence with non-brewster incidence angles is described by a complex formula in terms of the prism apex and incidence angles, and so it is difficult to see immediately what the total dispersion of the device would be. However, a little-known simple result [5] gives the total dispersion of an arbitrary sequence of prisms in terms of only the prisms dispersions and magnifications: the total dispersion is the sum of the individual dispersions, each weighted by the reciprocal of the total magnification that follows it. So the angular dispersion for an arbitrary sequence of four prisms and hence the dispersion at the output of the single-prism pulse compressor will be: 1 2 3 tot 23 4 3 4 4 Substituting the values for the dispersion and magnification given earlier, it's easy to see that the total device dispersion is necessarily identically zero, independent of the prism angle! Spatial chirp and pulse-front tilt: The symmetry of the device and lack of angular dispersion after two and four prism passes imply that the spatial chirp is also identically zero. This requires proper alignment of the roof mirror pair, but this is a relatively easy component to align, and it need only be aligned once. Also, when the spatial chirp and angular dispersion are zero, the pulse-front tilt must also be zero. We measured the spatial chirp and pulse-front tilt at the output of the compressor using GRENOUILLE[6, 7], and we found the pulse-front tilt angle to be less than 16 μrad. We can compare this value to that of a two- or four-prism design, in which, typically, a ~ 1 degree misalignment in a prism (which is likely in practice) causes a pulse-front tilt angle of >2000 μrad [8]. Throughput: As with any pulse compressor, we must also consider the throughput as the wavelength is tuned. And in this case, our pulse compressor s properties are identical to those of two- and four-prism compressors (except for a few extra reflections), so there s no need to repeat them here. Alignment: It is well known that the conventional pulse compressor is an alignment night mare that burns out grad students. But it is often claimed (usually by those who don't have to do the alignment themselves!) that a pulse compressor used for only one wavelength need only be aligned once and so can be set up without too much grief. However, keep in mind that, in conventional two- and fourprism designs, each prism can only be aligned by using the minimum-deviation condition: that the beam deviation will be minimal when the incidence and output angles are equal. However, this is a very poor alignment technique. This is because, at the minimum-deviation condition, the beam deviation angle de- Copyright 2015 Swamp Optics, LLC. 4 4

pends on the prism incidence angle only to second order (it's a minimum, after all!) and so is not a sensitive indicator of the correct incidence angle. On the other hand, the important quantity, the angular dispersion has a dependence on input angle that remains first order much stronger. Thus, minimum deviation is a poor alignment technique. Unfortunately, there is no other method for aligning a conventional pulse compressor. Worse, even if it is somehow perfectly aligned on one day, the next day, when the input beam has walked a bit in angle, the pulse compressor will no longer be aligned and so must then be re-aligned. So it s no surprise that conventional pulse compressors burn out grad students. At Swamp optics, we were once grad students, some of us very recently, and we are designing products that make this experience easier. We think our pulse compressor, which requires no alignment of its prism and which need not be re-aligned when the input beam moves, will help greatly, both in eliminating the alignment time and also yielding a distortion-free compressed pulse. In conclusion, the single-prism pulse compressor has all of the advantages of conventional pulse compressors, and none of their disadvantages. It solves essentially all of their problems, yielding a compact, alignment-free, easy-to-work-with device that is also inexpensive about half the price of other commercially available pulse compressors. 1. Bor, Z. and B. Racz, Group Velocity ispersion in Prisms and Its Application to Pulse Compression and Traveling-Wave Excitation. OC, 1985. 54(3): p. 165-170. 2. Rudolph, W. and B. Wilhelmi, Light Pulse Compression. 1989, Chur: Harwood Academic Publishers. 3. Johnson, A.. and C.V. Shank, Pulse Compression in Single-ode Fibers Picoseconds to Femtoseconds, in The Supercontinuum Laser Source, R.R. Alfano, Editor. 1989, Springer-Verlag: Berlin. p. 399-450. 4. Akturk, S., et al., Extremely simple single-prism ultrashort-pulse compressor. Opt. Expr., 2006. 14(21): p. 10101-8. 5. Trebino, R., Achromatic N-prism beam expanders: optimal configurations. Appl. Opt., 1985. 24(8): p. 1130-1138. 6. Akturk, S., et al., easuring pulse-front tilt in ultrashort pulses using GRENOUILLE. Optics Express, 2003. 11: p. 491-501. 7. Akturk, S., et al., easuring spatial chirp in ultrashort pulses using single-shot Frequency-Resolved Optical Gating. Optics Express, 2003. 11: p. 68-78. 8. Akturk, S., et al., The general theory of first-order spatio-temporal distortions of Gaussian pulses and beams. Optics Express, 2005. 13(21): p. 8642-8661. About Swamp Optics Founded in 2001, Swamp Optics, LLC offers cost-effective quality devices to measure ultrashort laser pulses. It specializes in frequency-resolved optical gating (FROG) and GRENOUILLE (an experimentally simple version of FROG), the gold standards for measuring the time-dependent (or, equivalently, frequency-dependent) intensity and phase of an ultrashort pulse. Swamp Optics also sells an innovative pulse compressor. For more information, visit us on the Web at www.swampoptics.com. Copyright 2015 Swamp Optics, LLC. 5